HomeMy WebLinkAboutNative Village of Tanacross dba Tanacross Village - Tanacross Woody Biomass Comm. Space Heating - Jun 2008 - REF Grant 7050881Preliminary Feasibility Assessment for High
Efficiency, Low Emission Wood Heating
In Tanacross, Alaska
Prepared for:
Ernest Arnold
Tanacross Village Council
Prepared by:
Daniel Parrent,
Wood Utilization Specialist
Juneau Economic Development Council
Submitted June 20, 2008
Notice
This Preliminary Feasibility Assessment for High Efficiency, Low Emission Wood Heating was prepared by
Daniel Parrent, Wood Utilization Specialist, Juneau Economic Development Council for Ernest Arnold, Tribal
Administrator, Tanacross Village Council, Tanacross, AK. This report does not necessarily represent the
views of the Juneau Economic Development Council (JEDC). JEDC, its Board, employees, contractors, and
subcontractors make no warranty, express or implied, and assume no legal liability for the information in this
report; nor does any party represent that the use of this information will not infringe upon privately owned
rights. This report has not been approved or disapproved by JEDC nor has JEDC passed upon the accuracy
or adequacy of the information in this report.
Funding for this report was provided by USDA Forest Service, Alaska Region,
Office of State and Private Forestry
2
Table of Contents
Abstract
Section 1. Executive Summary
1.1 Goals and Objectives
1.2 Evaluation Criteria, Project Scale, Operating Standards, General Observations
1.3 Assessment Summary and Recommended Actions
1.3.1 Tanacross Water Plant
1.3.2 Upper Tanana Regional Training Center
1.3.3 Tanacross Village Council, Multi-Purpose Facility
Section 2. Evaluation Criteria, Implementation, Wood Heating Systems
2.1 Evaluation Criteria
2.2 Successful Implementation
2.3 Classes of Wood Heating Systems
Section 3. The Nature of Wood Fuels
3.1 Wood Fuel Forms and Current Utilization
3.2 Heating Value of Wood
Section 4. Wood-Fueled Heating Systems
4.1 Low Efficiency High Emission Cordwood Boilers
4.2 High Efficiency Low Emission Cordwood Boilers
4.3 Bulk Fuel Boiler Systems
Section 5. Selecting the Appropriate System
5.1 Comparative Costs of Fuels
5.2(a) Cost per MMBtu Sensitivity – Cordwood
5.3 Determining Demand
5.4 Summary of Findings and Potential Savings
Section 6. Economic Feasibility of Cordwood Systems
6.1 Initial Investment Cost Estimates
6.2 Operating Parameters of HELE Cordwood Boilers
6.3 Hypothetical OM&R Cost Estimates
6.4 Calculation of Financial Metrics
6.5 Simple Payback Period for HELE Cordwood Boilers
6.6 Present Value, Net Present Value and Internal Rate of Return Values for Various HELE
Cordwood Boiler Installation Options
Section 7. Economic Feasibility of Bulk Fuel Systems
Section 8. Conclusions
References and Resources
Appendices
Appendix A AWEDTG Evaluation Criteria
Appendix B Recoverable Heating Value Determination
Appendix C List of Abbreviations and Acronyms
Appendix D Wood Fuel Properties
Appendix E Financial Metrics
Appendix F Operational Parameters of HELE Cordwood Boilers
Appendix G Garn Boiler Specifications
3
List of Tables and Figures
Table 4-1 HELE Cordwood Boiler Suppliers
Table 4-2 Emissions from Wood Heating Appliances
Table 5-1 Comparative Cost of Fuel Oil vs. Wood Fuels
Figure 5-1 Effect of White Spruce Cordwood Price on Cost of Delivered Heat
Table 5-2 Reported Annual Fuel Oil Consumption, Tanacross, AK
Table 5-3 Estimate of Heat Required in Coldest 24-Hour Period
Table 5-4 Estimate of Total Wood Consumption, Comparative Costs and Potential Savings
Table 6-1 Initial Investment Cost Scenarios for Hypothetical HELE Cordwood Systems
Table 6-2 Labor/Cost Estimates for HELE Cordwood Systems
Table 6-3 Summary of Total Annual Non-fuel OM&R Cost Estimates
Table 6-4 Simple Payback Period Analysis for HELE Cordwood Boilers
Table 6-5 PV, NPV and IRR Values for Various HELE Cordwood Boiler Options
4
Key words: HELE, LEHE, bulk fuel, cordwood
ABSTRACT
The potential for heating various facilities in Tanacross, Alaska with high efficiency, low emission
(HELE) wood-fired boilers is evaluated for the Tanacross Village Council (TVC).
Early in 2007, organizations were invited to submit a Statement of Interest (SOI) to the Alaska
Wood Energy Development Task Group (AWEDTG). Task Group representatives reviewed all the
SOIs and selected projects for further review based on selection criteria presented in Appendix A.
AWEDTG representatives visited Tanacross during the summer of 2007 and information was
obtained for the various facilities. Preliminary assessments were made and challenges identified.
Potential wood energy systems were considered for the projects using AWEDTG, USDA and AEA
objectives for energy efficiency and emissions. Preliminary findings are reported.
SECTION 1. EXECUTIVE SUMMARY
1.1 Goals and Objectives
• Identify facilities in Tanacross as potential candidates for heating with wood
• Evaluate the suitability of the facilities and sites for siting a wood-fired boiler
• Assess the type(s) and availability of wood fuel(s)
• Size and estimate the capital costs of suitable wood-fired system(s)
• Estimate the annual operation and maintenance costs of a wood-fired system
• Estimate the potential economic benefits from installing a wood-fired heating system
1.2 Evaluation Criteria, Project Scale, Operating Parameters, General Observations
• This project meets the AWEDTG objectives for petroleum fuel displacement, use of
hazardous forest fuels or forest treatment/processing residues, sustainability of the wood
supply, community support, and project implementation, operation and maintenance.
• Given annual fuel oil consumption estimates of 8,000 gallons (water plant), 10,000
gallons (Upper Tanana Regional Training Center), and 14,000 gallons (planned multi-
purpose facility) these projects would be considered “medium” in terms of their relative
sizes.
• Medium and large energy consumers have the best potential for feasibly implementing a
wood-fired heating system. Where preliminary feasibility assessments indicate positive
financial metrics, detailed engineering analyses are usually warranted.
• Cordwood systems are generally appropriate for applications where the maximum heating
demand ranges from 100,000 to 1,000,000 Btu per hour. “Bulk fuel” systems are generally
applicable for situations where the heating demand exceeds 1 million Btu per hour.
However, these are general guidelines; local conditions can exert a strong influence on the
best system choice.
• Efficiency and emissions standards for Outdoor Wood Boilers (OWB) changed in 2006,
which could increase costs for small systems.
5
1.3 Assessment Summary and Recommended Actions
Three facilities are considered in this report:
1.3.1. Tanacross Water Plant
• Overview. It was reported that the Tanacross water plant heats very cold incoming well-
water about 14 degrees before distributing the water to residences on the city water system.
Currently that amounts to approximately 20,000 gallons of water per day, requiring
approximately 2,337,000 net Btu. This heat is provided by three Weil-McLain Gold P-
WGO-5 boilers, rated at 152,000 Btu/hr net (each), with a firing rate of 1.45 gallons per
hour (each).
• Fuel Consumption. Assuming that the water plant heats 20,000 gallons per day by 14
degrees Fahrenheit, and operates 365 days per year, the annual fuel consumption would be
approximately 8,000 gallons.
• Potential Savings. At the projected price of about $5.00 per gallon, the Tanacross water
plant spends approximately $40,000 per year for fuel oil. The HELE cordwood fuel
equivalent of 8,000 gallons of #1 fuel oil is approximately 94 cords, and at $125 per cord
represents a potential annual fuel cost savings of $28,250 (debt service and non-fuel OM&R
costs notwithstanding).
• Required boiler capacity. The estimated required boiler capacity (RBC) to heat the water at
the Tanacross water plant is dependent on the amount of water to be heated per hour. The
installed capacity at the plant is currently 456,000 Btu (the combined capacity of the three
existing boilers). If the plant operates 10 hours per, and total daily production amounts to
20,000 gallons, then the minimum RBC would be approximately 234,000 Btu/hr.
• Recommended action regarding a cordwood system. Given the initial assumptions and
cost estimates for the alternatives presented in this report, this project appears to be cost-
effective and operationally viable. Further consideration is warranted. (See Section 6)
• Recommended action regarding a bulk fuel wood system. Given the heating demand, lack
of fuel supply, and the probable costs of such a project, a “bulk fuel” system is not cost-
effective for the Tanacross water plant.
1.3.2. Upper Tanana Regional Training Center
• Overview. The Upper Tanana Regional Training Center (UTRTC) is being developed at
the old Tok school building in Tok, AK. TVC has renovated a portion of the facility (the
gymnasium and adjacent spaces) for use as a construction trades training center, a
manufactured home facility and office space. This space occupies approximately 10,000
square feet. Heat is provided by two Weil-McLain series 78 boilers (model 778?) rated at
625,000 Btu/hr (net, each), with a maximum burner rate of 6.5 gallons per hour (each).
Whether or not the remainder of the building gets renovated and utilized remains to be
seen.
• Fuel Consumption. Fuel consumption at the UTRTC was not known. The estimated
consumption of 10,000 gallons per year is based on a projected average consumption of 1
gallon per square foot per year.
6
• Potential Savings. At the projected price of about $5.00 per gallon, the UTRTC spends
approximately $50,000 per year for fuel oil (based on the assumed 10,000 gpy). The HELE
cordwood fuel equivalent of 10,000 gallons of #1 fuel oil is approximately 117 cords, and at
$125 per cord represents a potential annual fuel cost savings of $35,375 (debt service and
non-fuel OM&R costs notwithstanding).
• Required boiler capacity. The estimated required boiler capacity (RBC) to heat the UTRTC
is approximately 345,793 Btu/hr during the coldest 24-hour period (based on the assumed
10,000 gpy).
• Recommended action regarding a cordwood system. Given the initial assumptions and
cost estimates for the alternatives presented in this report, this project appears to be cost-
effective and operationally viable. Further consideration is warranted. (See Section 6)
• Recommended action regarding a bulk fuel wood system. Given the heating demand, lack
of fuel supply, and the probable costs of such a project, a “bulk fuel” system is not cost-
effective for the UTRTC.
1.3.3. Tanacross Village Council, Multi-Purpose Facility (MPF)
• Overview. Tanacross Village Council is developing a 14,000 square foot Multi Purpose
Community Services Center (MPF) that will host a mid-level community health center,
Headstart center, social services offices and large meeting area. TVC has developed the
facility site, installed a concrete foundation and piped/water services to the building
foundation. TVC plans to complete the building in 2007/2008.
• Fuel Consumption. Since this is a new facility, fuel consumption at the TVC MPF is not
known. The estimated consumption of 14,000 gallons per year is based on a projected
average consumption of 1 gallon per square foot per year..
• Potential Savings. At the projected price of about $5.00 per gallon, TVC MPF will spend
approximately $70,000 per year for fuel oil. The HELE cordwood fuel equivalent of 14,000
gallons of #1 fuel oil is approximately 164 cords, and at $125 per cord represents a potential
annual fuel cost savings of $49,500 (debt service and non-fuel OM&R costs
notwithstanding).
• Required boiler capacity. The estimated required boiler capacity (RBC) to heat the TVC
MPF would be approximately 483,854 Btu/hr during the coldest 24-hour period, based on an
annual consumption projection of 14,000 gallons.
• Recommended action regarding a cordwood system. Given the initial assumptions and
cost estimates for the alternatives presented in this report, this project appears to be cost-
effective and operationally viable. Further consideration is warranted. (See Section 6)
• Recommended action regarding a bulk fuel wood system. Given the heating demand, lack
of fuel supply, and the probable costs of such a project, a “bulk fuel” system is not cost-
effective for the TVC MPF.
SECTION 2. EVALUATION CRITERIA, IMPLEMENTATION, WOOD HEATING SYSTEMS
The approach being taken by the Alaska Wood Energy Development Task Group (AWEDTG)
regarding biomass energy heating projects follows the recommendations of the Biomass Energy
7
Resource Center (BERC), which advises that, “[T]he most cost-effective approach to studying the
feasibility for a biomass energy project is to approach the study in stages.” Further, BERC advises
“not spending too much time, effort, or money on a full feasibility study before discovering whether
the potential project makes basic economic sense” and suggests, “[U]ndertaking a pre-feasibility
study . . . a basic assessment, not yet at the engineering level, to determine the project's apparent
cost-effectiveness”. [Biomass Energy Resource Center, Montpelier, Vermont. www.biomasscenter.org]
2.1 Evaluation Criteria
The AWEDTG selected projects for evaluation based on criteria listed in Appendix A. The
Tanacross projects meet the AWEDTG criteria for potential petroleum fuel displacement, use of
forest residues for public benefit, use of local processing residues, sustainability of the wood
supply, community support, and the ability to implement, operate and maintain the project.
In the case of a cordwood boiler system, the potential to supply wood from local forests appears
adequate and matches the application.
One of the objectives of the AWEDTG is to support projects that would use energy-efficient and
clean burning wood heating systems, i.e., high efficiency, low emission (HELE) systems.
2.2 Successful Implementation
In general, four aspects of project implementation have been important to wood energy projects in
the past: 1) a project “champion”, 2) clear identification of a sponsoring agency/entity,
3) dedication of and commitment by facility personnel, and 4) a reliable and consistent supply of
fuel.
In situations where several organizations are responsible for different community services, it must
be clear which organization would sponsor and/or implement a wood-burning project. (NOTE:
This is not necessarily the case with the projects in Tanacross but this issue should be addressed.)
With manual systems, boiler stoking and/or maintenance is required for approximately 10 to 20
minutes per boiler several times a day (depending on the heating demand), and dedicating
personnel for the operation is critical to realizing savings from wood fuel use. For this report, it is
assumed that new personnel would be hired or existing qualified personnel would be assigned as
necessary, and that “boiler duties” would be included in the responsibilities and/or job description
of facility personnel.
The forest industry infrastructure in/around Tanacross and the upper Tanana Valley is fairly well-
developed. For this report, it is assumed that wood supplies are sufficient to meet the demand.
2.3 Classes of Wood Heating Systems
There are, basically, two classes of wood heating systems: manual cordwood systems and
automated “bulk fuel” systems. Cordwood systems are generally appropriate for applications
where the maximum heating demand ranges from 100,000 to 1,000,000 Btu per hour, although
smaller and larger applications are possible. “Bulk fuel” systems are systems that burn wood chips,
sawdust, bark/hog fuel, shavings, pellets, etc. They are generally applicable for situations where the
heating demand exceeds 1 million Btu per hour, although local conditions, especially fuel
availability, can exert strong influences on the feasibility of a bulk fuel system.
Usually, an automated bulk fuel boiler is tied-in directly with the existing oil-fired system. With a
cordwood system, glycol from the existing oil-fired boiler system would be circulated through a
heat exchanger at the wood boiler ahead of the existing oil boiler. A bulk fuel system is usually
8
designed to replace 100% of the fuel oil used in the oil-fired boiler, and although it is possible for a
cordwood system to be similarly designed, they are usually intended as a supplement, albeit a large
supplement, to an oil-fired system. In either case, the existing oil-fired system would remain in
place and be available for peak demand or backup in the event of downtime in the wood system.
SECTION 3. THE NATURE OF WOOD FUELS
3.1 Wood Fuel Forms and Current Utilization
Currently, wood fuels in Tanacross will generally be in the form of cordwood and/or large
unprocessed sawmill residues (slabs, edgings). Residential use of cordwood has increased
significantly in the past 18 months due to sharply higher fuel oil costs. Given that higher demand,
prices for firewood have gone up accordingly.
3.2 Heating Value of Wood
Wood is a unique fuel whose heating value is quite variable, depending on species of wood, moisture
content, and other factors. There are also several recognized ‘heating values’: high heating value
(HHV), gross heating value (GHV), recoverable heating value (RHV), and deliverable heating value
(DHV) that may be assigned to wood at various stages in the calculations.
For this report, white spruce cordwood at 30 percent moisture content (MC30) calculated on the
wet weight basis (also called green weight basis), is used as the benchmark. [It should be noted
that other species are also present, including black spruce, white birch, cottonwood/poplar, willow
and aspen. And although white spruce is used as the “benchmark”, any species of wood can be
burned in a cordwood system; the most critical factor being moisture content, not species.]
The HHV of white spruce at 0% moisture content (MC0) is 8,890 Btu/lb1. The GHV at 30%
moisture content (MC30) is 6,223 Btu/lb.
The RHV for white spruce cordwood (MC30) is calculated at 12.22 million Btu per cord, and the
DHV, which is a function of boiler efficiency (assumed to be 75%), is 9.165 million Btu per cord.
The delivered heating value of 1 cord of white spruce cordwood (MC30) equals the delivered
heating value of 85.5 gallons of #1 fuel oil or 83.0 gallons of #2 fuel oil when the wood is burned
at 75% conversion efficiency.
A more thorough discussion of the heating value of wood can be found in Appendix B and
Appendix D.
SECTION 4. WOOD-FUELED HEATING SYSTEMS
4.1 Low Efficiency High Emission (LEHE) Cordwood Boilers
Outdoor wood boilers (OWBs) are relatively low-cost and can save fuel but most have been
criticized for low efficiency and smoky operation. These could be called low efficiency, high
emission (LEHE) systems and there are dozens of manufacturers. The State of New York
instituted a moratorium in 2006 on new LEHE OWB installations due to concerns over emissions
and air quality5. Other states are also considering or have implemented new regulations6,7,8,9. But
since there are no federal standards for OWBs (wood-fired boilers and furnaces were exempted
from the 1988 EPA regulations10), OWB ratings are inconsistent and can be misleading. Standard
9
procedures for evaluating wood boilers do not exist, but test data from New York, Michigan and
elsewhere showed a wide range of apparent [in]efficiencies and emissions among OWBs.
In 2006, a committee was formed under the American Society for Testing and Materials (ASTM)
to develop a standard test protocol for OWBs11. The standards included uniform procedures for
determining performance and emissions. Subsequently, the ASTM committee sponsored tests of
three common outdoor wood boilers using the new procedures. The results showed efficiencies as
low as 25% and emissions more than nine times the standard for industrial boilers. Obviously,
these results were deemed unsatisfactory and new OWB standards were called for.
In a news release dated January 29, 200712, the U.S. Environmental Protection Agency announced
a new voluntary partnership agreement with 10 major OWB manufacturers to make cleaner-
burning appliances. The new, Phase 1 standard calls for emissions not to exceed 0.60 pounds of
particulate emissions per million Btu of heat input. The Phase 2 standard, which will follow 2
years after Phase 1, will limit emissions to 0.30 pounds per million Btus of heat delivered, thereby
creating an efficiency standard as well.
To address local and state concerns over regulating OWB installations, the Northeast States for
Coordinated Air Use Management (NeSCAUM), and EPA have developed model regulations that
recommend OWB installation specifications, clean fuel standards and owner/operator training.
(http://www.epa.gov/woodheaters/ and http://www.nescaum.org/topics/outdoor-hydronic-heaters)
Implementation of the new standard will improve air quality and boiler efficiency but will also
increase costs as manufacturers modify their designs, fabrication and marketing to adjust to the
new standards. As a result, some low-end models will no longer be available.
4.2 High Efficiency Low Emission (HELE) Cordwood Boilers
In contrast to low efficiency, high emission cordwood boilers there are a few units that can
correctly be considered high efficiency, low emission (HELE). These systems are designed to burn
cordwood fuel cleanly and efficiently.
Table 4-1 lists four HELE cordwood boiler suppliers, two of which have units operating in Alaska.
HS Tarm/Tarm USA has a number of residential units operating in Alaska, and a Garn boiler
manufactured by Dectra Corporation is used in Dot Lake, AK to heat several homes and the
washeteria, replacing 7,000 gallons per year (gpy) of #2 fuel oil.14 Two Garn boilers were recently
installed in Tanana, AK (on the Yukon River) to provide heat to the washeteria and water plant,
and two were installed near Kasilof on the Kenai Peninsula.
Table 4-1. HELE Cordwood Boiler Suppliers
Btu/hr ratings Supplier
EKO-Line 85,000 to 275,000 New Horizon Corp
www.newhorizoncorp.com
Tarm 100,000 to 198,000 HS Tarm/Tarm USA
www.tarmusa.com/wood-gasification.asp
Greenwood 100,000 to 300,000 Greenwood
www.GreenwoodFurnace.com
Garn 350,000 to 950,000 Dectra Corp.
www.garn.com
Note: Listing of any manufacturer, distributor or service provider does not constitute an endorsement.
10
Table 4-2 shows the results for a Garn WHS 1350 boiler that was tested at 157,000 to 173,000
Btu/hr using the new ASTM testing procedures, compared with EPA standards for wood stoves and
boilers. It is important to remember that wood fired boilers are not entirely smokeless; even very
efficient wood boilers may smoke for a few minutes on startup.4,15
Table 4-2. Emissions from Wood Heating Appliances
Appliance Emissions
(grams/1,000 Btu delivered)
EPA Certified Non Catalytic Stove 0.500
EPA Certified Catalytic Stove 0.250
EPA Industrial Boiler (many states) 0.225
GARN WHS 1350 Boiler* 0.179
Source: Intertek Testing Services, Michigan, March 2006.
Note: *With dry oak cordwood; average efficiency of 75.4% based upon the high heating value (HHV) of wood
4.3 Bulk Fuel Boiler Systems
The term “bulk fuel” as used in this report refers, generically, to sawdust, wood chips, shavings,
bark, pellets, etc. Since the availability of bulk fuel is essentially non-existent around Tanacross,
the cost of bulk fuel systems is so high (i.e., $1 million and up), and the relatively small heating
demand for the projects under consideration, the discussion of bulk fuel boiler systems has been
omitted from this report.
SECTION 5. SELECTING THE APPROPRIATE SYSTEM
Selecting the appropriate heating system is, primarily, a function of heating demand. It is generally
not feasible to install automated bulk fuel systems in/at small facilities, and it is likely to be
impractical to install cordwood boilers at very large facilities. Other than demand, system choice
can be limited by fuel availability, fuel form, labor, financial resources, and limitations of the site.
The selection of a wood-fueled heating system has an impact on fuel economy. Potential savings
in fuel costs must be weighed against initial investment costs and ongoing operating, maintenance
and repair (OM&R) costs. Wood system costs include the initial capital costs of purchasing and
installing the equipment, non-capital costs (engineering, permitting, etc.), the cost of the fuel
storage building and boiler building (if required), the financial burden associated with loan interest,
the fuel cost, and the other costs associated with operating and maintaining the heating system,
especially labor.
5.1 Comparative Costs of Fuels
Table 5-1 compares the cost of #1 and #2 fuel oil to white spruce cordwood (MC30) In order to
make reasonable comparisons, costs are provided on a “per million Btu” (MMBtu) basis.
11
Table 5-1. Comparative Cost of Fuel Oil vs. Wood Fuels
FUEL RHVa
(Btu)
Conversion
Efficiencya
DHVa
(Btu)
Price per unit
($)
Cost per MMBtu
(delivered, ($))
4.50/gal 41.978
5.00 46.642 Fuel oil, #1,
(per 1 gallon) 134,000 80% 107,200
per gallon 5.50 51.306
4.50/gal 40.761
5.00 45.29 Fuel oil, #2,
(per 1 gallon) 138,000 80% 110,400
per gallon 5.50 49.819
100/cord 10.911
125 13.639 White spruce,
(per 1 cord, MC30)
12.22
million 75% 9.165
million 150 16.367
Notes:
a from Appendix D
5.2(a) Cost per MMBtu Sensitivity – Cordwood
Figure 5-1 illustrates the relationship between the price of white spruce cordwood (MC30) and the
cost of delivered heat, (the slanted line). For each $10 per cord increase in the price of cordwood,
the cost per million Btu increases by $1.091. The chart assumes that the cordwood boiler delivers
75% of the RHV energy in the cordwood to useful heat and that oil is converted to heat at 80%
efficiency. The dashed lines represent #1 fuel oil at $4.50, $5.00 and $5.50 per gallon ($41.978,
$46.642 and $51.306 per million Btu respectively).
At high efficiency, heat from white spruce cordwood (MC30) at $427.47 per cord is equal to the
cost of #1 fuel oil at $5.00 per gallon (i.e., $46.642 per MMBtu), before considering the cost of the
equipment and operation, maintenance and repair (OM&R) costs. At 75% efficiency and $125 per
cord, a high-efficiency cordwood boiler will deliver heat at about 29% of the cost of #1 fuel oil at
$5.00 per gallon ($13.639 versus $46.642 per MMBtu). Figure 5-1 indicates that, at a given
efficiency, savings increase significantly with decreases in the delivered price of cordwood and/or
with increases in the price of fuel oil.
12
Cost ($) per MMBtu as a Function of
Cordwood Cost
0.00
10.00
20.00
30.00
40.00
50.00
60.00
50 100 150 200 250 300 350 400 450
Cordwood cost, $ per cordCost ($) per MMBtu
Fuel Oil at $5.50 per gallon
Fuel Oil at $5.00 per gallon
Fuel Oil at $4.50 per gallon
Figure 5-1. Effect of White Spruce Cordwood Price on Cost of Delivered Heat
5.2(b) Cost per MMBtu Sensitivity – Bulk Fuels
Not included in this report
5.3 Determining Demand
Table 5-2 shows the reported approximate amount of fuel oil used by various facilities in
Tanacross, Alaska.
Table 5-2. Reported Annual Fuel Oil Consumption, Tanacross, AK
Reported Annual Fuel Consumption Facility Gallons Cost ($) @ $5.00/gallon
Water plant 8,000 40,000
UTRTC 10,000 50,000
TVC MPF 14,000 70,000
TOTAL 32,000 160,000
13
Wood boilers, especially cordwood boilers, are often sized to displace only a portion of the heating
load since the oil system will remain in place, in standby mode, for “shoulder seasons” and peak
demand. Fuel oil consumption for the Tanacross facilities (except the water plant) was compared
with heating demand based on heating degree days (HDD) to determine the required boiler
capacity (RBC) for heating only on the coldest 24-hour day (Table 5-3). While there are many
factors to consider when sizing heating systems it is clear that, in most cases, a wood system of
less-than-maximum size could still replace a substantial quantity of fuel oil and save money.
Typically, installed oil-fired heating capacity at most sites is two-to-four times the demand for the
coldest day. It appears that the Tanacross facilities fall within this range, although the heating
capacity of the of the heating system ay the TVC MPF is unknown (non-existent; new
construction).
Manual HELE cordwood boilers equipped with special tanks for extra thermal storage can supply
heat at higher than their rated capacity for short periods. For example, while rated at 950,000
Btu/hr (heat into storage), a Garn WHS 4400 can store nearly three million Btu, which,
theoretically, would be enough to heat for the UTRTC during the coldest 24-hour period for about
8½ hours (2,932,000 ÷ 345,793).
Table 5-3. Estimate of Heat Required in Coldest 24-Hour Period
Facility Fuel Oil Used
gal/yeara
Heating
Degree Daysd Btu/DDc Design
Tempd F
RBCe
Btu/hr
Installed
Btu/hra
Water plant 8,000 NA 234,000
(estimated)
525,000 (gross)
456,000 (net)
UTRTC 10,000 69,610 345,793 1,250,000
TVC MPF 14,000
15,400
(Gulkana data)
208,831
-54
483,854 unknown
Table 5-3 Footnotes:
a From SOI and site visit; net total Btu/hr
b NOAA, July 1, 2005 through June 30, 2006:
ftp://ftp.cpc.ncep.noaa.gov/htdocs/products/analysis_monitoring/cdus/degree_days/archives/Heating%20degree%20Days/Monthly%20City/2006/jun%202006.txt c Btu/DD= Btu/year x oil furnace conversion efficiency (0.85) /Degree Days
d Alaska Housing Manual, 4th Edition Appendix D: Climate Data for Alaska Cities, Research and Rural Development
Division, Alaska Housing Finance Corporation, 4300 Boniface Parkway, Anchorage, AK 99504, January 2000.
e RBC = Required Boiler Capacity for the coldest Day, Btu/hr= [Btu/DD x (65 F-Design Temp)+DD]/24 hrs
According to these calculations (Table 5-3), it appears that the Tanacross facilities could each,
technically, supply 100% of their heating needs with one or more high efficiency low emission
cordwood boilers. Consultation with a qualified engineer is justified and strongly recommended.
5.4 Summary of Findings and Potential Savings Table 5-4 summarizes the findings thus far: annual fuel oil usage, range of annual fuel oil costs, estimated annual wood fuel requirement, range of estimated annual wood fuel costs, and potential gross annual savings for the facilities in Tanacross. [Note: potential gross annual fuel cost savings do not consider capital costs and non-fuel operation, maintenance and repair (OM&R) costs.] Table 5-4. Estimate of Total Wood Consumption, Comparative Costs and Potential Savings Fuel Oil Used gal/yeara Annual Fuel Oil Cost (@ $ ___ /gal) Approximate Wood Requirementb Annual Wood Cost (@ $ ___ /unit) Potential Gross Annual Fuel Cost Savings ($) CORDWOOD SYSTEMS 4.50/gal 5.00/gal 5.50/gal W. spruce, MC30, CE 75% 100/cord 125/cord 150/cord Low Medium High Water plant 8,000 36,000 40,000 44,000 94 cds 9,400 11,750 14,100 21,900 28,250 34,600 UTRTC 10,000 45,000 50,000 55,000 117 cds 11,700 14,625 17,550 27,450 35,375 43,300 TVC MPF 14,000 63,000 70,000 77,000 164 cds 16,400 20,500 24,600 38,400 49,500 60,600 Total 32,000 144,000 160,000 176,000 375 cds 37,500 46,875 56,250 87,750 113,125 138,500 NOTES: a From Table 5-2 b From Table D-3, Appendix D
SECTION 6. ECONOMIC FEASIBILITY OF CORDWOOD SYSTEMS
6.1 Initial Investment Cost Estimates
DISCLAIMER: Short of having an actual Design & Engineering Report prepared by a team of architects
and/or professional engineers, actual costs for any particular system at any particular site cannot be
positively determined. Such a report is beyond the scope of this preliminary assessment. However, several
hypothetical, though hopefully realistic, system scenarios are offered as a means of comparison. Actual
costs, assumptions and “guess-timates” are identified as such, where appropriate. Recalculations of
financial metrics, given different/updated cost estimates, are relatively easy to accomplish.
Wood heating systems include the cost of the fuel storage building (if necessary), boiler building
(if necessary), boiler equipment (and shipping), plumbing and electrical connections (including
heat exchangers, pumps, fans, and electrical service to integrate with existing distribution systems),
installation, and an allowance for contingencies.
Before a true economic analysis can be performed, all of the costs (investment and OM&R) must
be identified, and this is where the services of qualified experts are necessary.
Table 6-1 (next page) presents hypothetical scenarios of initial investment costs for cordwood
systems in medium-sized heating demand situations. One scenario is presented for each facility. It
should be noted, however, that these scenarios are strictly hypothetical. The solutions presented
here are not necessarily the best or correct or only choices; consultation with qualified
professionals is strongly recommended.
Buildings and plumbing/connections are the most significant costs besides the boiler(s). Building
costs deserve more site-specific investigation and often need to be minimized to the extent
possible. Piping from the wood-fired boiler is another area of potential cost saving. Long
plumbing runs and additional heat exchangers substantially increase project costs. The exorbitant
cost of hard copper pipe normally used in Alaska now precludes its use in most applications. If
plastic or PEX® piping is used significant cost savings may be possible.
Allowance for indirect non-capital costs such as engineering and contingency are most important
for large systems that involve extensive permitting and budget approval by public agencies. This
can increase the cost of a project by 25% to 50%. For the examples in Table 6-1, a 25%
contingency allowance was used.
NOTES:
a. With the exception of the list prices for Garn boilers, all of the figures in Table 6-1 are
gross estimates.
b. The cost estimates presented in Table 6-1 do not include the cost(s) of any upgrades or
improvements to the existing heating/heat distribution system currently in place.
15
16
Table 6-1. Initial Investment Cost Scenarios for Hypothetical HELE Cordwood Systems
Fuel oil consumption, gallons per
year
8,000
(water plant)
10,000
(UTRTC)
14,000
(TVC MPF)
Required boiler capacity (RBC),
Btu/hr 234,000 (?) 345,793 483,854
Garn model (2) Garn WHS 2000 (1) WHS 4400 (2) WHS 3200
Rating -Btu/hr e 850,000 950,000 1,900,000 Cordwood boiler
Btu stored 2,544,000 2,932,000 4,128,000
Building and Equipment (B&E) Costs, $ (for discussion purposes only)
Fuel storage buildinga
(fabric bldg, gravel pad, $20 per sf)
37,600
(94 cds @ 20 sf/cd)
46,800
(117 cds @ 20 sf/cd)
65,600
(164 cds @ 20 sf/cd)
Boiler building @ $125 per sf
(minimum footprint w/concrete pad)b
32,000
(16’x16’)
27,500
(10’x22’)
50,000
(20’x20’)
Boilers
Base pricec
Shippingd
Bush delivery d
29,800
5,000
NA
40,000f
4,500
NA
65,800
8,000
NA
Plumbing and electricald 15,000 15,000 15,000
Installationd 10,000 10,000 10,000
Subtotal - B&E Costs 129,400 143,800 214,400
Contingency (25%)d 32,350 35,950 53,600
Grand Total 161,750 179,750 268,000
Notes:
a A cord occupies 128 cubic feet. If the wood is stacked 6½ feet high, the area required to store the wood is 20 square feet per cord.
b Does not allow for any fuel storage within the boiler building
c List price, Alaskan Heat Technologies, April 2008
d “guess-timate”; for illustrative purposes only
e Btu/hr into storage is extremely fuel dependent. The data provided for Garn boilers by Dectra Corp. are based on the ASTM standard of split, 16-inch oak
with 20 percent moisture content and reloading once an hour. f Published list price not available; this represents the current list price for WHS 3200 + $7,100
6.2 Operating Parameters of HELE Cordwood Boilers
A detailed discussion of the operating parameters of HELE cordwood boilers can be found in
Appendix F.
6.3 Hypothetical OM&R Cost Estimates
The primary operating cost of a cordwood boiler, other than the cost of fuel, is labor. Labor is
required to move fuel from its storage area to the boiler building, fire the boiler, clean the boiler
and dispose of ash. For purposes of this analysis, it is assumed that the boiler system will be
operated every day for 210 days (30 weeks) per year between mid-September and mid-April.
Table 6-2 presents labor/cost estimates for various HELE cordwood systems. A detailed analysis of
labor requirement estimates can be found in Appendix F.
17
Table 6-2. Labor/Cost Estimates for HELE Cordwood Systems
System
(2) WHS 2000
(combined capacity)
(94 cds/yr)
(1) WHS 4400
(117 cds/yr)
(2) WHS 3200
(combined capacity)
(164 cds/yr)
Total Daily labor (hrs/yr)a
(hrs/day X 210 days/yr) 317.27 229.53 273.61
Total Periodic labor (hrs/yr)b
(hrs/wk X 30 wks/yr) 47.0 58.5 82.0
Total Annual labor (hrs/yr)c 40 20 40
Total labor (hrs/yr) 404.27 308.03 395.61
Total annual labor cost ($/yr)
(total hrs x $20) 8,085.40 6,160.60 7,912.20
Notes:
a Appendix F, Table F-2
b Appendix F, Table F-3
c Appendix F
There is also an electrical cost component to the boiler operation. An electric fan creates the
induced draft that contributes to boiler efficiency. The cost of operating circulation pumps and/or
blowers would be about the same as it would be with the oil-fired boiler or furnaces in the existing
heating system.
Lastly there is the cost of wear items, such as fire brick, door gaskets, water treatment chemicals,
etc. For the following examples, a value of $1,000 per boiler is used.
Table 6-3. Summary of Total Annual Non-Fuel OM&R Cost Estimates
Cost/Allowance ($)
Item (2) WHS 2000
(combined capacity)
(94 cds/yr)
(1) WHS 4400
(117 cds/yr)
(2) WHS 3200
(combined capacity)
(164 cds/yr)
Labora 8,085.40 6,160.60 7,912.20
Electricityb 836.89 333.40 467.78
Maintenance/Repairs 2,000.00 1,000.00 2,000.00
Total non-fuel OM&R ($) 10,922.29 7,494.00 10,379.98
Notes:
a From Table 6-2
b Electrical cost based on a formula of horsepower x kWh rate x operating time. Assumed kWh rate = $0.32
6.4 Calculation of Financial Metrics
Biomass heating projects are viable when, over the long run, the annual fuel cost savings generated
by converting to biomass are greater than the cost of the new biomass boiler system plus the
additional operation, maintenance and repair (OM&R) costs associated with a biomass boiler
(compared to those of an oil- or gas-fired boiler or furnace).
18
Converting from an existing boiler to a wood biomass boiler (or retrofitting/integrating a biomass
boiler with an existing boiler system) requires a greater initial investment and higher annual
OM&R costs than for an equivalent oil or gas system alone. However, in a viable project, the
savings in fuel costs (wood vs. fossil fuel) will pay for the initial investment and cover the
additional OM&R costs in a relatively short period of time. After the initial investment is paid off,
the project continues to save money (avoided fuel cost) for the life of the boiler. Since inflation
rates for fossil fuels are typically higher than inflation rates for wood fuel, increasing inflation rates
result in greater fuel cost savings and thus greater project viability.17
The potential economic viability of a given project depends not only on the relative costs and cost
savings, but also on the financial objectives and expectations of the facility owner. For this reason,
the impact of selected factors on potential project viability is presented using the following metrics:
Simple Payback Period
Present Value (PV)
Net Present Value (NPV)
Internal Rate of Return (IRR)
Total initial investment costs include all of the capital and non-capital costs required to design,
purchase, construct and install a biomass boiler system in an existing facility with an existing
furnace or boiler system.
A more detailed discussion of Simple Payback Period, Present Value, Net Present Value and
Internal Rate of Return can be found in Appendix E.
6.5 Simple Payback Period for HELE Cordwood Boilers
Table 6-4 presents a Simple Payback Period analysis for hypothetical multiple HELE cordwood
boiler installations.
Table 6-4. Simple Payback Period Analysis for HELE Cordwood Boilers
(2) WHS 2000
(combined capacity)
(94 cds/yr)
(1) WHS 4400
(117 cds/yr)
(2) WHS 3200
(combined capacity)
(164 cds/yr)
Fuel oil cost,
$ per year @ $5.00 per gallon
40,000
(8,000 gal)
50,000
(10,000 gal)
70,000
(14,000 gal)
Cordwood cost
$ per year @ $125 per cord
11,750
(94 cds)
14,625
(117 cds)
20,500
(164 cds)
Annual Fuel Cost Savings, $/yr 28,250 35,375 49,500
Total Investment Costs b, $ 161,750 179,750 268,000
Simple Paybackc, yrs 5.73 5.08 5.41
Annual, Non-fuel OM&R costsa 10,922 7,494 10,380
Net Annual Savings ($)
(Annual Cash Flow) 17,328 27,881 39,120
Notes:
a From Table 6-3
b From Table 6-1
c Total Investment Costs divided by Annual Fuel Cost Savings
19
6.6 Present Value (PV), Net Present Value (NPV) and Internal Rate or Return (IRR)
Values for Various HELE Cordwood Boiler Installation Options
Table 6-5 presents PV, NPV and IRR values for hypothetical various HELE cordwood boiler
installations.
Table 6-5. PV, NPV and IRR Values for Various HELE Cordwood Boilers Options
(2) WHS 2000
(combined capacity)
(94 cds/yr)
(1) WHS 4400
(117 cds/yr)
(2) WHS 3200
(combined capacity)
(164 cds/yr)
Discount Ratea (%) 3
Time, “t”, (years) 20
Initial Investment ($)b 161,750 179,750 268,000
Annual Cash Flow($)c
(Net Annual Savings) 17,328 27,881 39,120
Present Value
(of expected cash flows, $ at “t” years) 257,797 414,799 582,007
Net Present Value ($ at “t” years) 96,047 235,049 314,007
Internal Rate of Return
(% at “t” years) 8.69 14.47 13.42
See Note # _ below 1 2 3
Notes:
a real discount (excluding general price inflation) as set forth by US Department of Energy, as found in NIST publication NISTIR 85-3273-22 (Rev 5/08),
Energy Price Indices and Discount Factors for Life Cycle Cost Analysis, April 2008
b From Table 6-1
c Equals annual cost of fuel oil minus annual cost of wood minus annual non-fuel OM&R costs (i.e., Net Annual Savings)
Note #1. With a real discount rate of 3.00% and after a span of 20 years, the projected cash flows are worth $257,797
today (PV), which is greater than the initial investment of $161,750. The resulting NPV of the project is $96,047 and the
project achieves an internal rate of return of 8.69% at the end of 20 years. Given the assumptions and cost estimates, this
alternative appears financially and operationally feasible.
Note #2. With a real discount rate of 3.00% and after a span of 20 years, the projected cash flows are worth $414,799
today (PV), which is greater than the initial investment of $179,750. The resulting NPV of the project is $235,049 and
the project achieves an internal rate of return of 14.47% at the end of 20 years. Given the assumptions and cost estimates,
this alternative appears financially and operationally feasible.
Note #3. With a real discount rate of 3.00% and after a span of 20 years, the projected cash flows are worth $582,007
today (PV), which is greater than the initial investment of $286,000. The resulting NPV of the project is $314,007 and
the project achieves an internal rate of return of 13.42% at the end of 20 years. Given the assumptions and cost estimates,
this alternative appears financially and operationally feasible.
SECTION 7. ECONOMIC FEASIBILITY OF BULK FUEL SYSTEMS
The discussion of bulk fuel systems is not included in this report
20
SECTION 8. CONCLUSIONS
This report discusses conditions found “on the ground” at various facilities in Tanacross, Alaska,
and attempts to demonstrate, by use of realistic, though hypothetical, examples the feasibility of
installing high efficiency, low emission cordwood boilers to heat these facilities.
The facilities in Tanacross consist of three distinct entities and are described in greater detail in
Section 1.3. They include:
1. Tanacross water plant
2. Upper Tanana Regional Training Center (UTRTC) at the old Tok school building
3. Tanacross Village Council Multi-Purpose Facility (new, planned, partly constructed)
In terms of sites, none of the proposed project sites appear to present any significant geo-physical
constraints for the construction of individual wood-fired heating plants. In fact, the conditions in
the general area of the projects appear to be quite favorable for construction projects.
Each of the facilities under consideration could be heated with a HELE cordwood boiler system;
none of the facilities appears too small and none appears too large.
Typically, the greater the fuel oil replacement the better the cost-effectiveness, but all of the proposed
projects in Tanacross show strong financial metrics. However, all of these metrics are predicated on
two assumptions: 1) that sufficient volumes of wood can be provided at a reasonable cost and 2) that
someone will tend the boilers. Failure on either count will compromise the success of the project(s).