ALASKA INTERTIE MANAGEMENT COMMITTEE AGENDA Tuesday,January 5,2016 9:00 a.m.-11:00 am Alaska Energy Authority,Board Room 813 W.Northern Lights Boulevard,Anchorage,Alaska 1.CALL TO ORDER 2.ROLL CALL FOR COMMITTEE MEMBERS 3.PUBLIC ROLL CALL 4.AGENDA APPROVAL 5.PUBLIC COMMENTS 6.APPROVAL OF PRIOR MINUTES -December 2,2015 7.OLD BUSINESS A.Reliability and Operating Standards B.Douglas substation upgrade proposal -MEA C.Teeland Bypass substation proposal -IOC 8.NEW BUSINESS A.Election of Chairman 9.IOC /OPERATORS REPORT -ML&P/GVEA 10.BUDGET COMMITTEE UPDATE 11.COMMITTEE ASSIGNMENTS 12.NEXT MEETING DATE 13.ADJOURNMENT To participate via teleconference,dial 1-888-585-9008 and use conference room code 467 050 126 10C /Operator Report 1/5/2016 1.Alaska Intertie Status Report a.2015 MWH Usage at Douglas Substation i.First quarter:142,077 MWH ii.Second quarter :118,397 MWH tii.Third quarter:93,528 MWH iv.Fourth quarter:106,069 MWH d v.2015 Total:460,071 MWH qryo OrWe "ak \02.System operation Jy seer HudSonehee sycten wide bonedmank "Case120HeelZzTrppedDi)linea.See attachmentA b.Alaska Intertie tripped with 30 MW's flowing north Wednesday 12/30/15 at 0558 -Trip coincides with MEA's 115kV line tripping between Teeland Sub and Hospital sub.Douglas breaker 138-B1 was closed at 0606. 3.Compliance Report a.None 4.Alaska Intertie SVC update a.Teeland,Healy and Gold Hill SVC in service. i.Crews Scheduling installation of new exhaust louvers to minimize coal dust entering the control building. 5.Intertie Operating Committee a.develop new spinning reserve allocation and reconcile standards between the IMC and RRO Reliability Standards.Update provided to IMC. b.Work with EPS and Henri Dale to revise/add the following Railbelt Reliability Standards. i.AKBAL-002 Disturbance Control Performance ii.AKTPL-001 thru 4 Transmission Planning iii.PRC-O06 Automatic underfrequency load shedding c.Review additional balancing,Protection,Facility and Reserve Standards. 6.Machine Ratings Subcommittee a.Update MRSC online data base 7.Operations,Maintenance and Scheduling Subcommittee 8.Dispatch and System Operations Subcommittee 9.Budget Subcommittee 10.Engineering,relay and Reliability Subcommittee a.Technical review of MEA's proposal for a Teeland bypass. b.Review Douglas Substation Protection Upgrade Project 11.System Studies Subcommittee a.UFLS Study 12.SCADA and Telecommunications Subcommittee a.Review and make recommendation -SLMS communication upgrade proposal provided by EPS. i3Hoi-nob Ready yeh.KIRO .Homer AANS radhy cone thurgd .Paseo Bor ¥moeSpinot)wlb«\aet One,os.Wress eo pickin,AdRrently.Dred GU NSnivSqrNodongTWiceTan$nyt ka Farad cloe FH (0cty (MC.Pp tn ls promise Ey taka Lo MartIdanRottJooredWotWeisfallingto5Srapproved.Vidoy wotksessian vs]Toe £thear wpleretiny Imeby line,lore vg decks Yehis Wee."?3 TRLOL-03 daleted TUPOS exists EPO]Hence -thea not ready nact wh .Shooting Tor end Tan.Wartety 1|28 Tot 4 tlt mechirgs oched Led,by FAL ie QVEA : we,Kirk>.dond van appro pra.%Nat 5 padod,DW,MEA Twuncdk 20%LInterdie Ownedvy[drat Contract Guay Fkirk dora.Shed QL?Zoie Proyecd DPeutt br doable. IC Teetland "Burke sent to (elay probechen comme -he Doc tbg .Féchrieai =4 Ncoumedadins [add studies. TA LK .OMe Jahnston -cerwrETPEMUER,heinCheehago”[BREN q -ISR (0 +100,00 EPS 4420 =.40:50ove2Byrscetied90:79 eS TSUAM IMC:Jan.5,2016 ALASKA ENERGY AUTHORITY Intertie Management Committee at-aanYV. Roll Call Agenda MinutesRollcallfromtoptobottomendingwithChair Yes No Yes No Yes he,Yes No Yes No Wa Nv. Golden Valley Electric Association Co RY YY aN Matanuska Electric Association e WA RY Alaska Energy Authority {au rv Y Municipal Light &Power See Breart WA Chugach Electric Association bo Y 1a. sa Up Es ve hg wo A TOTAL ||L ||| Roll call from top to bottom ending with Chair Yes No Yes No Yes No Yes No Yes No Golden Valley Electric Association Matanuska Electric Association Alaska Energy Authority Municipal Light &Power Chugach Electric Association TOTAL Next Meeting: Intertie Management Committee Regular meeting MEETING MINUTES Tuesday,January 5,2016 Anchorage,Alaska 1.CALL TO ORDER Chair Joe Griffith called the meeting of the Intertie Management Committee to order on January 5, 2016 at 9:00 a.m.A quorum was established. 2.ROLL CALL FOR COMMITTEE MEMBERS Brian Hickey Chugach Electric Association (CEA)Pe Cory Borgeson Golden Valley Electric Association (GVEA) Joe Griffith Matanuska Electric Association (MEA)© Kirk Warren Alaska Energy Authority (AEA Jeff Warner Anchorage Municipal Light &Power (ML&P) 3.PUBLIC ROLL CALL Burke Wick (CEA);Gary Kuhn,Ed Jenkin,Tony Izzo (MEA);Kirk Warren,Teri Webster (AEA);Gary Agron,Anna Henderson,John Dunn (ML&P);Mark Johnson (CEA);Monica Grassi,JohnBurns(GVEA);Bob Day (Homer Electric Association (HEA));John Foutz (City of Seward);KirkGibsonMOentiRackner&Gibson PC);Brian Blorkauist et of Law);Dave oiespie 6.APPROVAL OF PRIOR MINUTES -December 2,2015 7.OLD BUSINESS7A.Review of Reliability StandardsMr.Dale said the reliability standard updates are almost ready.When they are presented to the IMCandapprovedtherewillbefourimplementphaseswithspinningreservesstandardsbeingthelast phase due to SCADA issues and computers needed to be reprogramed. A workshop meeting was set up for January 21 in Fairbanks for the IMC committee to review the standards line by line. 7B.Douglas substation upgrade proposal Following up from the last meeting,Mr.Warren stated no reappropriation is needed to use the existing appropriation originally appropriated for the extension of the intertie.Because MEA (private)owns 30%and AEA (public)owns 70%of the asset drafting up a contract is difficult but doable.Mr.Warren will be working with Mr.Kuhn on a draft contract. IMC Meeting Minutes-January 5,2016 Page 2 of 2 7C.Teeland bypass substation proposal Mr.Wick stated the proposal for MEA to construct a new substation to directly connect MEA's 115kV transmission system to the IMC controlled 138kV line between Teeland and Douglas substation has been sent to the Engineering,Relay and Reliability subcommittee (ERR)to review. The ERR will submit their recommendations by January 28. 8.NEW BUSINESS 8A.__Election of chairmanChairJoeGriffithannouncedhis resignation due to his retirement from MEA after 28 years ofservice.His last dayis January 11,2016.Nominations were given.Mr.Borgeson nominated Mr. Mark Johnston from ML&P as Chair. Motion:Mr.Borgeson made a motion to close nominations for chair and elect Mr.Johnston aschair.Motion seconded by Mr.Hickey.The motion passed unanimously.Since Mr.Johnston was not present,Mr.Hickey (Vice-Chair)took over the meeting. 9.REPORTS 9A._Intertie Operating committee report /Operators ReportMr.Warner gave the Operators and IoC report. of 9/30/15 expenses totaled.$200,000 Most expenses come inat the end of the year (June).11.COMMITTEE ASSIGNMENTSystem.Studies Subcommittee -Doa system wide data collection of generation dispatch,eventrecordersandPSSE,and run aa benchmark against the 12/30/15 line trip.10.NEXT.MEETING DATE.Call of the chair* 12.ADJOURNMENT. There being no further business ofthe IMC,the meeting adjourned at 9:54 a.m. Mark Johnston,Chairman Kirk Warren,Secretary ALASKA INTERTIE MANAGEMENT COMMITTEE AGENDA Tuesday,January 5,2016 9:00 a.m.-11:00 am Alaska Energy Authority,Board Room 813 W.Northern Lights Boulevard,Anchorage,Alaska 1.CALL TO ORDER 2.ROLL CALL FOR COMMITTEE MEMBERS 3.PUBLIC ROLL CALL 4.AGENDA APPROVAL 5.PUBLIC COMMENTS 6.APPROVAL OF PRIOR MINUTES -December 2,2015 7.OLD BUSINESS A.Reliability and Operating Standards B.Douglas substation upgrade proposal -MEA Cc.Teeland Bypass substation proposal -IOC 8.NEW BUSINESS A.Election of Chairman 9.10C/OPERATORS REPORT -ML&P/GVEA 10.BUDGET COMMITTEE UPDATE 11.COMMITTEE ASSIGNMENTS 12.NEXT MEETING DATE 13.ADJOURNMENT To participate via teleconference,dial 1-888-585-9008 and use conference room code 467 050 126 Intertie Management Committee Regular meeting MEETING MINUTES Wednesday,December 2,2015 Anchorage,Alaska 1.CALL TO ORDER Chair Joe Griffith called the meeting of the Intertie Management Committee to order on December 2, 2015 at 9:31 a.m.A quorum was established. 2.ROLL CALL FOR COMMITTEE MEMBERS Brian Hickey Chugach Electric Association (CEA) Cory Borgeson Golden Valley Electric Association (GVEA) Joe Griffith Matanuska Electric Association (MEA) Kirk Warren Alaska Energy Authority (AEA). Jeff Warner Anchorage Municipal Light &Power (ML&P) 3.PUBLIC ROLL CALL Burke Wick (CEA);Gary Kuhn,Ed Jenkins,Tony Izzo,David Pease (MEA);Kirk Warren,Teri Webster (AEA);Mark Johnston,Karen Bretz (ML&P);Mark Johnson (CEA);Allen Gray (GVEA); Bob Day (Homer Electric Association (HEA));Kirk Gibson (McDowell Rackner &Gibson PC); Brian Bjorkquist (Dept.of Law);Dave Gillespie (ARCTEC);Dave Burlingame (EPS);Henri Dale; and Bernie Smith. 4.AGENDA APPROVAL MOTION:Mr.Borgeson made a motion to approve the agenda as presented.Motion seconded by Mr.Hickey.The agenda was adopted without objection. 5.PUBLIC COMMENTS None 6.APPROVAL OF PRIOR MINUTES -October 16,2015 MOTION:Mr.Borgeson made a motion to approve the prior minutes of Oct.16,2015.Motion seconded by Mr.Hickey.The motion was approved unanimously. 7.OLD BUSINESS 7A.Review of Reliability Standards integration proposals from EPS and Henri Dale The committee reviewed the two proposals from EPS and Henri Dale,LLC.Updating the reliability standards will be a joint effort between the two.Initial focus will be on the Balancing Standards and the underfrequency load shedding system.Mr.Dale's previous and ongoing work of combining the Regional Reliability Organization (RRO)and IMC standards will not be effected and were not a part of this recent proposal submission. One major item lacking in the standards are established measurables that they both have been instructed to incorporate. The final version is due by the end of December in order to present to RCA by the time they open the reliability standards 1/1/16. IMC Meeting Minutes-December 2,2015 Page 2 of 3 MOTION:Mr.Borgeson made a motion to approve a combined $100,000 to amend and update the Reliability Standards from EPS and Henri Dale,LLC.Motion seconded by Mr.Hickey.The motion was approved unanimously. 7B.Spin Requirements --IOC Recommendations There has been an agreement on the allocation of the spin requirements and all of the standards.The documents are currently being reviewed by all the participants and expect only a few edits.It should be in final form in a week. Mr.Griffith noted that the IMC is the in house keeper of the reliability standards and spin requirements.The IOC is the technical knowledge behind it.It is a living document. 7C.SVC Warranty Policy update Mr.Warren presented the offer from Alstrom for a five-year term contract plus a three-year warranty. The warranty will cover spare parts.The one million contract includes 24/7 telephone support and training and maintenance in year one and five with an assessment on year three.Since this was a sole source procurement,the Department of Transportation needs to review and approve the sole source. It is expected to be approved within a week. MOTION:Mr.Borgeson made a motion that all the utilities support the decision to go with this sole source procurement.Motion seconded by Mr.Hickey.The motion was approved unanimously. 7D.Douglas substation upgrade Discussed getting guidance to use the existing appropriation originally appropriated for the extension of the intertie.A formal proposal from the IMC is needed stating the need and the scope of work. MEA will present the proposal at the next meeting. 8.NEW BUSINESS 8A.Teeland Bypass substation approval -MEA Mr.Kuhn presented the proposal for MEA to construct a new substation to directly connect MEA's 115kV transmission system to the IMC controlled 138kV line between Teeland and Douglas substation. There was no motion. 9.REPORTS 9A._Intertie Operating committee report /Operators Report Mr.Warner gave the Operators and IOC reports. Mr.Johnston gave an update on the recovery of the ML&P worker who was shocked in October.His recovery is going well and a full recovery is expected.A GoFundMe account was set up to help with medical expenses and with donations from all the utilities 24K was raised. 9.COMMITTEE ASSIGNMENTS e MEA isto bring a formal proposal for the Douglas substation upgrade to the next meeting. e The Budget committee is to give an update at the next meeting. IMC Meeting Minutes-December 2,2015 Page 3 of 3 e¢IOC is to look at the technical aspect of the Teeland Bypass proposal using the IMC adopted Transmission Interconnection Standards and bring it back to the committee. 10.NEXT MEETING DATE Call of the chair.Mr.Griffith would like the next meeting to be held before his retirement on January 8,2016.) 12.ADJOURNMENT There being no further business of the IMC,the meeting adjourned at 10:50 a.m. Joe Griffith,Chairman Kirk Warren,Secretary To obtain an audio of the full meeting,contact Teri Webster (AEA)at 907-771-3074. oS. MEAMATANUSKAELECTRICASSOCIATION MEMORANDUM DATE:November 25,2015 TO:Intertie Management Committee FROM:Matanuska Electric mw n GunSUBJECT:Teeland Bypass Substation MEA is planning on the construction of a new substation to directly connect MEA's 115kV transmission system to the IMC controlled 138kV line between Teeland and Douglas Substations.Therefore,pursuant to Section 6.4 of the Amended and Restated Alaska Intertie Agreement of March 2014,MEA is requesting the IMC authorize such improvements as detailed in the attached Protection and Control Description and electrical drawings. MEA believes these design documents are sufficient to demonstrate the ability of the proposed facility to interconnect to the existing transmission system so "as not to reduce the intertie's reliability'.All improvements shall be implemented in accordance with "Prudent Utility Practice”as demonstrated most recently by the interconnection of Hane Substation by Chugach Electric and the construction of the substation at Clear by GVEA. At this time,MEA is seeking approval with conditions for the construction of the Teeland Bypass Substation,based upon the configuration and protection philosophy outlined in the provided attachments.Once the conditions are met,MEA would be authorized to interconnect to the Alaska Intertie.After all 138kV and 115kV relay settings have been reviewed and approved by the appropriate subcommittee of the IMC,the interconnection could proceed pending operational scheduling and coordination with the intertie operator. The studies would be consistent with those required for the Hane and Clear substations performed by other Railbelt utilities. Enc:Teeland Bypass Protection and Control Description Selected electrical drawings Teeland Bypass 138kV Substation Protection and Control!Description This paper describes the general protection philosophy to be implemented for the Teeland Bypass 138kV substation;the final,detailed protection schemes will be developed after execution of a relay coordination analysis.All protection schemes described herein are fully redundant,equally robust systems.Although the individual relays have the suffix --P (primary)and -S (secondary),the level of functionality,reliability and security is equal between the two systems. The physical and protection/control designs described herein are designed to improve the 138kV system reliability by (1)introducing a ring bus configuration at Teeland Bypass and (2)installation of 400-series Schweitzer relays.The 400 series relays allow for high-speed tripping of faults and the ability for future use of synchrophasers to monitor system stability. Teeland Bypass Substation Electrical Description: The Teeland Bypass substation is designed to be an air-insulated,138-115kV facility located southwest of the City of Wasilla.The station in its original build-out will consist of a 3-breaker ring bus on the 138kV side with a 2-breaker collector bus configuration on the 115kV side connected by a 75/100/125MVA autotransformer.The station is electrically connected at the 138kV level in between Teeland substation,and the Douglas Substation,which is located approximately 25 circuit-miles distant to the north. The high-side circuit breakers are Alstom type DT1-145FK-F1 SF6 gas power circuit breakers,rated 145kV,2000 amperes continuous,and 40k amperes interrupting.The circuit breakers are labeled as MT262,MT362 and MT462.Circuit breakers MT262 and MT362 will frame the autotransformer;MT362 and MT462 will frame the Teeland Bypass-Douglas circuit and MT262 and MT462 will frame the Teeland Bypass-Teeland circuit.Line disconnect switches are provided to allow for de-energizing the 138kV line while keeping the ring bus closed.The line disconnects are labeled MT269 for the Teeland Bypass-Teeland circuit and MT469 for the Teeland Bypass-Douglas circuit. Protection Overview: Line protection for the 138kV circuits are provided by SEL-411L and SEL-421 numerical relays.The SEL-411L is an advanced line differential protection,automation and control system relay.Among its features are:phase and ground distance,synchronism check,over-current (time and instantaneous), over and under voltage,automatic reclosing and line differential capabilities.The SEL-421 is functionally equivalent to the SEL-411L except that the SEL-421 lacks line current differential capability. Breaker failure (stuck breaker)protection is provided using the SEL-451,a protection,automation and bay controller relay.Teeland Bypass bus protection is provided by the overlapping zones of protection from the two line circuits and transformer differential zone. Stub bus programming will be provided to modify tripping from the remote terminal if the local line disconnect switch is open (MT269 or MT469)but the corresponding framing circuit breakers are closed.Stub bus logic is enabled as soon the line disconnect opens causing zero currents to be transmitted to the remote ends and receipt of direct transfer-trip signals to be blocked. In addition to the direct protection schemes described here,indirect system parameters such as loss-of-potential and trip coil monitoring will also be incorporated into the overall protection and contro! philosophy. Teeland Bypass-Douglas 138kV Line Protection: Line protection for the Teeland Bypass-Douglas circuit,protection will consist of a combination of line current differential (87L)and step-distance (21P)elements using a permissive overreaching transfer-trip (POTT)scheme.The POTT scheme will utilize two,forward-looking zones:zone 1 will under-reach the remote terminal and zone 2 will over-reach the remote end.Reach settings will be determined during the relay coordination analysis. Upon detection of a fault on the protected line,the following logic will be executed: e For line current differential (87L),relays at each terminal will send a trip signal their local circuit breakers with no intentional time delay,key direct transfer-trip to the remote end and initiate breaker failure logic. e For step-distance (21P),a zone 1 fault will initiate immediate local circuit breaker tripping, generate a transfer-trip signal to the remote end and initiate breaker failure logic.Detection of a zone 2 fault will result in the transmission of a permissive trip signal to the remote end and initiate a local countdown timer.If the countdown timer times out and the permissive trip signal is still present,the local circuit breaker(s)will be commanded to be tripped and breaker failure logic initiated. Teeland Bypass-Teeland 138kV Line Protection: Because of the short line length between the Teeland and Teeland Bypass Substations,it is anticipated that line protection on this circuit will be primarily line current differential,however,the relay coordination analysis may suggest additional elements can be engaged to enhance protection reliability and/or system security. The difference between the Teeland Bypass-Teeland and the Teeland Bypass-Douglas protection schemes is that Teeland Bypass-Teeland will rely only on 87L protection for both primary and secondary systems. Upon detection of a fault on the protected line,the following logic will be executed: e For line current differential (87L),relays at each terminal will send a trip signal their local circuit breakers with no intentional time delay,key direct transfer-trip to the remote end and initiate breaker failure logic. Transformer T1 Protection: Autotransformer T1 will be differentially protected via an SEL-387E Current Differential Relay and an SEL-487E Transformer Protection Relay.Protective elements that are anticipated for use are current differential protection,phase and ground overcurrent,negative sequence,frequency and voltage protection.On the 115kV side of the transformer,two circuit breakers provide protection against low-side faults.The differential zone of the transformer includes the transformer and the 138kV circuit breakers: the 115kV circuit breakers are protected separately. Transformer T1 is framed by circuit breakers MT262 and MT362;therefore a transformer fault will require clearing both of these circuit breakers.As with the line protection schemes described previously, detection of a fault condition initiates breaker failure (stuck breaker)logic.In the case of transformer T1, the breaker failure schemes for MT262 and MT362 cross trip each other;that is,a fault condition identified for circuit breaker MT362 will initiate breaker failure logic for MT262 and visa-versa.The rational for this is that any fault detected by one transformer protection scheme should be detected by the other,thus clearing both circuit breakers. Breaker-Failure Protection: Breaker failure (stuck breaker)protection for all the Teeland Bypass circuit breakers will be provided using one SEL-451 per circuit breaker.If breaker failure is detected,the breaker failure relay trips a lock out relay,re-trips the affected circuit breaker and sends a direct transfer trip signal to the next upstream circuit breaker. MATANUSKA ELECTRIC ASSOCIATION,INC. Palmer,Alaska DRAFT MOTION for Intertie Management Committee Review and Consideration December 2,2015 Teeland Bypass Substation Construction Move that the IMC approve the construction of the Teeland Bypass Substation by MEA as outlined in the electrical drawing as well as,the relay and control description included in MEA's attached transmittal,conditioned upon:(1)the IOC review and approval of relay settings;and (2)completion of |OC-required studies demonstrating no reduction in intertie reliability.These studies will be consistent with those performed for the interconnection of GVEA's substation at Clear Air Force Station and Chugach's Hane Substation. t wrasse18008 CONT 923-cevTs, T 70/1200:1 mplolTOM3-o--8wrest wr303 16004 16008 MT462 MT362Doom O we03 wre600At cov ft ccvt #3S-cev ° TOOTH /N13.B¥-86.4¥TEOMRVAISBV-66.447700/1200:FOO /1200:1 ---__}-_---.MACREA/ANOERSON ore He MT262 auTo Tenet Otwnze70008wiseTeo0afal16004 }-- 7208 a HOLD -_saw H™-¢ eaKy weov ev wean UNE ISSUED FOR BID ONLY NOT FOR CONSTRUCTION _110143 TEELAND BYPASS SUBSTATION UPGRADES THe.Stane =Daawne NO/SEET 7 Taree Ta =oncacr enanera,E.GOIS/S.WORCESTER,STANLEY CONSULTANTS-05 >Matanuska Electric A ve ee RETERENCE CRA NCETMUMN/SECTION Ceserren TEELAND BYPASS SUBSTATION DESIGN7CONS TRUCT ON/ASBUILT REVSION 138KV/115KV SWITCHING DIAGRAM 'SUEDFORCLENT REWEW -CONTRO,ENCLOSUREISSHLDFORCONRO,ENCLOSURE OD 13 Way ISSUED FOR GENERAL CONSTRUCDON CONTRACTOR BO M E Palmer,AK 99648 oT .(907)761-0900DAATAMUSKAELECTIICASSOCIATION'WYN MEA.COOP "we MTSS-EL 0001 occ 1 wt To TEE-wTR/SAL-735125voc(+)(THs DWC)2p [LEGENDISSUEDFORBIDONLY©TERMINAL BLOCK ®X THE RELAY/CONTROL MARSHALLING CABOETryTs ?poe NOT FOR CONSTRUCTION _1101"3_fa SHORTING TERNAL BLOCK RELAY /CONTROL MARSHALLING CABINET t '©DEVICE TERMINAL \»FIELD EQUPMENT TERNAL 1 t 1 i i 1 H SMALAR TO HOSPITAL SUBSTATION mftnNG TO/FROM LUNE DISCONNECT 1 SWITCH 9 AND b CONTACTS WAL BE SPARED.NO STUB SUS PROTECTION i ete AOMMED.AL THES TE. 1 i] 1 i] i 1 1 f PO pede tenn rn rrr npr tn fn ssn pon rp 7 eee I Tien FRE VO AGOGASE-T AOOBASE -FX TX=T3E 7 {Seis t one |eae ' 1 ieee SST*q mom ORK e | ce 2!°18&'pa °1 -ae 1 als?Bi ( "1g2 Qo be 4 eee def -------4 --------}-------}-------}---------4 ---4 -------------}---}---------------------------&|.¥i -203MRo4.ABER OPTIC TO 1300rm FIBER OPTIC TO8asFIBERDISTRIBUTIONPANELFIBEROFSTRIBUTIONPANELIRANSCEVER]FIBER CXSTRIBUTION PANEL '(rer.y (REF.OWG 1)(REF pwc 1) 'TO SATELLITE LOCK i (REF.OM 1) 1 1 TO ETHERNET TCH f (REF.0WG 1) { { i] i] i] i t 1 { t i t ape vy©a, YO TEE-uTR/SEL-7: 125 Woe (-)(THS O96) nnpT' i] ) =mE{Prexiil EUNChONS owt #¥To re 3 oa ere . y 2 1 -yD a!bor ree we urze2dieBL©oat es »|am |S me of ,oesityuo|sabes gGwe 3:Ld oe |oe TY a y H iz pont 2 PoRT 3 PORT 4A PoRT 4a PORT Ac |BS Ho ; --4 B03 -'ousz0g B4 30 /676F -u7282 2110CTHCAmETSHLTCH'on 1 2 fx Lows Dec 1)1 BO?Boe 5 4i)rs3%. eos Bs Bur 1682ourmseecoe4 7 to :Pret UNC TONS on on mo Ss 6REE.i FUNCRONS ae BKR M1262 THIS,-_-t_ass as Ste om es m4Paneoutz06 so/oneg urea 5 Tun oe wen urse2 |ras Bs pe?8 =im Si0 owS735uncronsDedSPARE- 3s ned . arr =m °(vas)KEY O7T owe OvT205.ee Te?.(2)10 237 e33 ae aeTEE-MTR FAILURE ALARIE 'OLD FoR sexy Os -SPARE -SHOP OG raed 0S .ay a2 an eo (wore 1)'ee bec et see wong |? KV OS.part -SPARE -wrz6e meOESO'ca OW et -sane -cond -Sara Coa I -(wc)on a ane FUTURE,5 SPARE 'SPARE -SPARE - ola ™-P FARURE ALARA ' -'SPARE -SPARE -PARE - ow os Bay me ess B30 eroect:TEELAND BYPASS SUBSTATION _ENG.STAMP 'iat WO.|_DRAWNG NO /SHEET REFERENCE DRAWING /DE TAN /PLAN/SECTION DESCRIPTION CRAG WARE aDESONFR/PROKCT ENGNeee:R.GOIS/S,WORCESTER,STANLEY CONSULTANTS 100 p Matanuska Electric Association han sD allie Alaa TEELAND BYPASS SUBSTATION NO.DESIGN/CONSTRUGNON/ASHUILT_REVISION DWN BY/DATE RE vieWi O_RY/DATE 2 [w1ss-1-7100/1 TOK CIRCUIT GREAKER MT262 GREAKEA FAILURE OC SONFWATC 138KV TEELAND LINE OTR Cote ae TRTREEC OT SIS PA PLN ST OS OTT 3__[urss-e1-2103/1 VSEKV ORCUIT BREAKER MT482 BREAKER FALURE DC SCHEMATIC PRIMARY PROTECTION AND METERING'SSUED FOR CONROL CNCLOSURE BO A!aaaey/Scl 09/00/15 |R_EPSEN/SCI 11/01/13 tes «_[wiss-B-2705/1 24408 OC SCHEMATIC DC SCHEMATIC°rx oeas |Z|MISS=€L-2208/2 24a OC SCHEMATIC 78s ©_[wrss-a.-2500/1 1SBCY GACT BREAKER WIZ82 OC SCHEMAS wT ows _--|w1ss-0,-2501/1 1SOKY ORCUIT BREAKER WT462 OC SCHEMATIC 7MATANUSKASLECTIOCASSOCIATIONWWWMEACOOPF-5Tarss-m-soo CONTROL ENCLOSURE OC PANELS DOr,C7 iii MTSS-EL-2101 Jeers 1 aul LEGEND 0)28 Fan ISSUED FOR BID ONLY 1 TERWINAL,BLOCK WATE RELAY/CONTROLAIARSHALLING CABINET aa 2/0 bz NOT FOR CONSTRUCTION _110173 _ur SHORTING TERANAL BLOOK 1 RELAY/CONTROLAMARDIALLIKG CABNET i)@ DEMCE TERMINAL !4Cars 17K pox »FELO EQUIPMENT TERMINAL t Ta7=72tby 32 ry 1 +BAe TLeeor-wrzez [eco -urse2 NOTES:1 OR W262 7 u LAR TO HOSPITAL SUBSTATION WRING TO/FROM LINE DISCONNECTi)oeior a AND D a aswu BE SPARED.NO STUB 8US PROTECTION1SB46WALLBEPROCRAMWEDA) !137-00 1 fy i)mB 15-4 i)ity 2 t ui /TS 1m /Ave MI FB Mi Fo 1 5/0, H { ! 1 !7 Mesi)1 SEL-40 '1seFY! -1 ce 2Lanboa I i i)it nt"lye bt 1bel!tJ i '2 1 !300%"OER oeNE 10 '3¢0n Neer come 70FIGERDISTRIBUTIONPANELFIBERDISTRIBUTIONPANEL (PEF.OWS 1)'(REF.OW 1)(REF.8G 1) 'TO ETHERNET SWITCH \(REF,OG 1) 1 i) 1 f 1 1 i) 1 1 f i) 1 1 1 1 i) 2f0 ?s©a4 BEE.seta,euNcrons ONG. +por 8-7 ax 1262ouT201TRECOK2aeTP pos Boz 1 2 -tBOSourz0z ae soperee-tae2 807 34 7 it BOD 1s-7 KR UTESourzesTREcon2™eP mes ere, guna GUC TONS oe bil soos (oon)KR M1282 THis +41ess(vx)ase Ste o BS ourzos 8-7 sofa _wrata zo)os BXR M1462 ™S BS ate ?8 B35 ase Sis ow errGa)avon [us ona ose,as?338 are are FOR.Soe DRETNE PRBS}|nes 7awe40wor)om 7 BER UT462 (SKY DS.ive PLOcK OSE 'y D.:THIS .41269-oo)so |lee fw #4eo(uz mr SPARE -O88 ourz07 SPARE 7 ozsone- Bas B48 -t 420 Tee-s(oe)out208 FAILURE,ALARM ,SPARE -Ba?acs a 830 NO]DRAWNG NO./S*EET REFEREMCE DRAWNG/DETAR /PLAN/SECTION DESCRP TION9|wISS-EL-3001/1 CONTROL ENCLOSURE DC PAMELS 'DCI','DC2" Proect,TEELANDBYPASS SUBSTATION ENG.STAMP Matanuska Electric Association NO.|DRAWNG NO /SHEET REFERENCE DRAWNG/DETAL/PLAN/SECTION DESCRIPTION anaer Wa TEELAND BYPASS SUBSTATIONS/8._WOR S_0s ¢:1_[wrss-m-007071 ORE-UNE DIAGRAM DESIGN/CONSTRUCTION/ASBUILT REVISION OWN BY/DATE REVIEWED BY /OATE 2_|Miss-£1-2100/1 138K¥CRCUIT BREAKER M1262 BREAMER FAURE OC SCHEMATIC.138KV TEELAND LINE SOC we TBA RE OTT 3 TSECV GROUT BREAKER MT46Z BREAKER FAILURE OC SCHEMATIC SECONDARY PROTECTION TSSUED_FOR CONTROL,ENCLOSURE OO a ave09 ORAS sence wy L 24408 DC SCHEMATIC DC SCHEMATICbingeies3TSORVCIRCUITBREAKERWI262DCSCKEWA(00 178 8 T3OKV CIRCUIT BREAKER MT262 OC SCHEWATI FF Omwee$000 5 TSEKV CIRCUIT BRFAKER T4867 DC SCHEMAT SSTMATANUSKAELECTRICASSOGATIONCOOPaTursst1-250172 T3BKW_GRCUMT BREAKER WT@62 DC SCHEMATI MTSS-EL-2102 [eer lot LEGEND©TERMPAL BLOCK IV THE RELAY/CONTROL MARSHALLING CABINET67x4 @ SHORTING TERMINAL BLOCK th RELAY/CONTROL AMARSHALLING CABINET 2 .7 ISSUED FOR BID ONLY Oe MCE FERALNOTFORCONSTRUCTION_01t3__©FIELD EQUIPMENT TERMINAL an |Lane TF sensouia02 ry 28 hs-7 hs hs-7 8/0 StL=45 EUNCTIONS oweouriot5 T coxr-urzez |nes LoScouy_RELAY 5 2H}pwctnasaosoz12 Se{ 'TS-31ounIG2228,i}BAR WT282eSem |,t lel 1 ad At 3 4 9806 -MT2821phIanesBitte|4 1 2 -3 ge Lf -la.--}+-----4--------4------------ --}- ------4------------}---}- -------8F --4 41 Fo SYNC CHECK (75)dears contac rar:FUNC RON oweaes108 ale canes ; wizez |nesaresamacuoexLmroenanaersuovaneoeeeeeeaCad(REF.OWGEd 208 DE pee -wizez |mesHibai-tr4+-4-x mest!Hed_urze?erry 7 Boor ize?ee wane .--_Ba ts cr pt x osha 5 ane ale 2 mw +,-uy (BOOF -T2627 HTS,12 10 coun mocanon |Owe7Roce|ety.ceor-urzez |THsDEOBenyaFronwONTORINDICATIONOFC'SPARE -ys >)y sew _wizer |mas1282TERMINALPOINTS:ows" z 2 wes -wiez [ws!ti «|mete Vouton |Ome16B1262TREHS,REE,1 1 x{SEL-451 euNcrONs om ouno?"I*SPARE -'<4 mal a COL MON TOR SEAL -IN |DAC1He-Syp ye x SPARE - {{©(wr KR M1262 TS aS ae =<\{pee an sm o 3}||ee ce (+)source |owe'23 71 ne or wr262 er «|aoa |!en Fan et bas outtos 'So/ezer ratuae |3 rc ORR W362(os)z42anasonve--ane a Boa *me cout tee |1938-4p-4+-2 x swe :SPAR - rn eos oR wT367ala=O(wad)-s-Bo NT ta ee [074ourzorSPARE-7 y x aura ?ee ce'SPARE -Boz BOs OxR UTE62athe:-Pptee mee tee |87-s 4-4 x >a -SPARE -eos .oxR uTae?ey os)nen oureo2 ed ty ee recat tine |*oe |?-sap :SPARE -Ors aSPARE-4outa°F SPARE --t4,4-2 A SPARE - TN zexOarrr u 53jy x SPARE -PANT |*oy Teree'we =B33 chy com uTz04 3 oMe .-%tiae TD x xEy DTT 3 3 Bie as =x hetated =(oo me Ean |7 Ea aB35oeomBENSmrepcaton |3/-_+-__ft esexnurzez|nas ourzes 27 spare . -S a x at wy oe rae cee tuoneron |O%_2,4,x ae a8 Be '4,4,*Pant -=On ve | =zry40-S 4-4}4 -x eae - oar .-py x SPARE -SPARE -azz B23 2 BBataaa1+--4}x Pane - 7 Be zfo)Ho ee x are : °'SPE -oureo?-os ene 120 Salenad soy x SPARE - B26 827 -?44 x Pane - SPARE -BAS (=)oes oa -8 4-4-8-x SPARE - aourzo879PARE-S44.1 PARE -(occ)SPARE - =Sea?ase a30 en -s 4-4 «Pane - 'MODEL g7EPB060 NO.DRAWNG NO./SMHEET REFERENCE DRAWNG/DETAL /PLAN/SECTION DESCRETION[9 [wrss-a-250172 {S8K¥ORGAT OREAKER W148?OC SCHEWATC10|MTSS &L-2502/1 J3OKY CORCAT BREAKER WT362 DC SCHEMATIC 1 |tS$-EL-2502/2 JJOKV CROAT BREAKER MI362 DC SCHEMATIC 5 Tan aeproact,TEELAND BYPASS SUBSTATION ENG.STAMP 7 -NO.|DRAWNG NO./SHEET REFERENCE DRAWNG/DETAIL/PLAN/SECTION DESORPTION a 0.ro ee Se et ae \aton ;SS L36KV CIRCUIT BREAKER.MT202NC'DF S.CN/CONSTRUCTION/ASBUILT REV'SION OM BY/DATE REVEWED @Y/DATE 12 |MTSS-EL-2101/1 ASOKV TEELANO LINE PRIMARY PROTECTION AMO METERING DC SCHEMATIC Dp CR RBA OVS RPA EC OOO 3 _[wrss-e-z102/1 T3OKY TEELAND URE SECONOAAY PROTECTION OC SCHEMATIC BREAKER FAILUREi[ssuep For conmo,oSuRE BD 'A BARRY/SO)09/08/13 PSN ASO I/Os |$3 eet:wey [2 ]wiss-0 210071 1YSeV TRO UNE PRWARY PROTECTION AND METERWG DC SCHEMATIC DC SCHEMATICAK908455|MISS-EL-2205/1 24408 OC SCHEWATICppatanh@[wiss-e1-2500/1 13OCW CIRCUIT BREAKER M1262 DC SCHEMATIC wT owas:-_#900 [7 |wiss-.-2800/2 1JOKV_CRCUIT BREAKER WI762 OC SCHEMATIC Tena nOASSOCATION«--WWMEA.COOP ;DAATANUSKA ELECTING MEA a_[urss-tu=2501/1 1SeXV GROUIT BRCAKER 7467 DC SCHEWATIC MTSS-EL-2100 [ue 1 io J CONSTRUCTION NOTES:4 LEGEND 1,MEA TO VERIFY BASED ON RELAY SETTINGS.1.SPARE TRANSFORWER CT CABLES LANDED G TERWINAL BLOCK @ THE RELAY/CONTROR (MARSHALLING CABINETMARSHALLUNGCABINETAWDGROUNDED,@ SHORTING TERMINAL BLOCK IN.RELAY/CONTROL/MARSHALLING CABINET ©DEWCE TERMINAL ©FELD COUPMENT TERRA CONTINUED ISSUED FOR BID ONLY er Nuc 3NOTFORCONSTRUCTION_110113 AS 447 lesanan,\3ecv BUS zst4:i pT 4 a wz >oxolessvtx PRETRY-2eOv/20Y Ly ns"a POWER AUTOTRANSTORMER NO.1 (TI)HOLD 1SOKv/11 Svey1200.5 Mae 1200:3 MR 1200.5 PS/DO/ZS vARadWETERNGANma.faa mn 1200:5 uk '208 wa 1200:5 MR\12 ary an any S"h ae 37 T ae ar ala 'rou ven |8NL433.am foWaal Fest 72 ay lise wT3e7 ctoF25'oe ae 780 UME EF.DwG }assaeyaesaeaeAy 2 Be ==qs-1wcovt_tL gx tog9iy ,Ip?|TB x revsiziclszalsisecov 1x aces!my ge|cy? s[3)3|3)3/3/3[3 rows)¢1x togertt!198 wen 298 Ls aye= 7 !! =WO 7 ex Caen eis 2 1200:5 ¥R 1B?een Fy LoxFVBOMV/1SBv-O64Tio30A-S/SL-WE TS-10 700/1200;1 |,GO¥L #2LEBOKBor?2a iaWs q_ZIS'_8 s10 [Yes 1 a is 77Ksage!re ews 4 zis U3 14 apo Los,a vax_41/DN!tetwvyex_¥IfoNe 1pHK1ée-15!za CWS 7a te rssaeie wine 1%t 1 yas i i x"/DNe ead3Im:5 Bea |1 De CONSTRUCTION WOTE1-TPxadi7Q01-6 F201 saw TT 2ge 8K te 1297 save p29)78rowoxn7g14-131 703 ew q_tpe!Mca 2m 6g 145-43 L299 wT ,_NOL UAT?3 2 way 218teact1gewageotizsew,_melissque ran spo saga lay wnt,_22 lis sous Lit hy 9.3)28 per ne ||Tix v Te 6p Hn |L}'De }Tes TB ||Tes 3OEE12MK,_IQ?|BSNO gH ogee ape)72 wm,pl eoat0 gnWapN1NOOxpImtise1pogagegeon,By Las ge 2 on B s 16 "i 212 KX 4 raul !oe 7mm F253 'ete IOWA 4,FOL,ye yess c [reF ows 1 L 2p oye L i es yCloses3crossaatTeer Z ee]ts!4ape?(igs aK,297]nO QO apa gee?ge ee oT 8 SIO oye.= een no wx Tiasgte 7m eg tape hype es4 ygs ty sgte yd row par CONSTRUCTION NOTE1repsizexatlies2AospoYop38!pes ,_rys1738 yes M5362 CT t 7AM Gf i 1 on Bz {m2 m2 |1 m2Dyegr§Lam we,_2ye,Toye 7g soa vopeg lpr ut,spe!2oceerTAK149g)3 |208 WW Age Nate 7g ego tae Igo at ,_yo!Mspwe,7px t8c-17!298 Ow Lssqe 7pm age tase)ys et nz sacqie Be ane an '{ Sonne - =a |'T4wyvs!oso gx fy VIS |ag Od wu arlene Or }ego f Hf6sfac1MAD;8510 fxVt vay _W1/0K9HedDoosanB]1166 Aor vey Mt /pe10 wry egy 7002 paoxct,TEELAND BYPASS SUBSTATION.ENG STAMP :wa Deawne 0 ET GERENEE DONG /BETAL PLN SECTION DESC TON RTE SRS pesioner/proect enanter:K_GOIS/S.NORCESTER,STANIEY CONSULTANTS os g Matanuska Electric Association i”Taras ora [Time Warne 30 Soa TEELAND BYPASS SUBSTATIONVoOFSIGNCONSTRUCTION/ASBUILT REVISION 'OWN BY DATE RIVED BY/OAE 2 [wisn 120/240 VAC STATION SERWCE TMREE-URE_DIAGRAW fit aT TOCA RE CL A i THREE-LINE AC SCHEMATICB|issued FoR CONTROL ENCLOSURE BD AL BARRY/SCI O0/08/AS-TR”PSEN7SCL NI/OT/1S eyMEA"=== j _(907)761-9300MMXTANUSKAELECTINGASSOCIATION.«|WWW Tea HO MTSS-EL-Otdt [oe tiv 1 x {7 | Ro ran)or >Ey >sfEligext, oay saucy MCOY wa a eel b x .a\\-dd wT wT Cis wt $200,5 1200-5 Mat 1200.5 Mt 1700.5 1200.5 ae 1200.5 WR LalEB100.8 wa tn0m3 wR 1700.3 1200-5yh 1200.8wR 1200,5 Ey cS en ct \enenc C800 a 'coo Setene wertane 'a0 xacon,paws ves nen ne,ae -¥a a ee el a a elka ha a 'P|ca an oowel con Ey Waal arn ary ot he rnaWet fonts Raval 3 nr N fest (oaWal &am om 'a Gy ye Bs 2 !'a++]4]Fe Psy fF !oot ie -+[sl -Po™leoWa'mats joo¥al a nn am aeWeN cnn,rn Fa¥oo mN footen meNel laa¥oN pun ambs4is4++}$f .+E +f a :a a iz j if:-r r =e Loaglzizalalalalalglelyaelzlelslalstal-etelelz GEE CC MESETCED 312,318 Pees aslsal elelels DEE Meee 3/3/35 3s)als Bla)3]5 3/a/a]3 FIFEIE a Bla]aia B/a/s|>Slala/s 31/3)/5)2 FIRIEIE?5/5/53 ala/3|5 3/3/3/3 3)3/315 ABER,SR ENS a to ayn-p 10 wm FiPverec1verBoZ 3 HSS 5 -To T8D-MTR To TO-S Yo 1BO-Pononowatxlelsver)ar,Owe Po ST =glade ometoTZA292LIHewey Sa!QOG-MIR/SEL-Z8OanaPOEtooeTZiwa22|Tae sx 15,MAM MUNA BSvagt3|Wz t 'Les Me CY+a BY Mgr 33|2Bwp 26 {NH Spe poss293 ae,Tinqia 57a 5. tec-17 |20616 is nc |+EX Magee38 1293 BW AIBA MAGI?50 agFBp28tage28aBLcysTi i 1 Sk Uopey)1198 oe age ngs sige ge tam ++Byres i H Ey o® Sere °Co----->Py TJ saw we Ti)1)TEE-S/5EL =411 G-3 TS)ware IS)Tf ae GesVogeTaptwI,TSS MG 2p soe9 Cap aw1g]TOSS Spe topery [agi ie,iga|2s Bui $e Noe9 [207 ae Age)IE 1 1VYapse13179sowA296M2an2ptaets!29s aw 4296!noc?Sigh vager§3.1799 ow qT UN oye age 4g =ex 484 Wage aa Le Tepe7 LIDS Ow A FBO Ne ty 2g eg 7 |298 Om 796 |is acys 310737 1298 eHA_TBS Is Se +o a 1x B28 "8 aa Ab fe H {1x ape s !Pyead {4 sie gx ,Ted Coonan Sexe =1 ilaa.Bs |15-6 Te3 |(BS CONTEcommenA2H10G-9 1297 tax p28)78 qe2 m2 Orr?|Zp2 ww,2 IO afr be ows IpK Mgrs L2g9 WK q__710)Way?aig Nope9 TID aw ABE,IS tape 298 ew A IBS]ye Qo REF.DG1 BEOK ape wpe ia era aa lingie QE Me 13Sgw pA wipes!me cw,aps ayia apnec-7A?Lt p_Z IYO T n 27H i 4g sap 17 |205 ge lig sce L i ap Tibi Coocaae 3 nea 1 1 tliccses 3 Tein "Poo ass \ee)Syn)1 298 ax 297,B10 BUA 12g iz0 Ox 290 |1st 4 ign14)18 |ap ex zy |W718 4pmHLreLo------a Us 2QH 1055-9 F797 ax x _298)7,982QKMyre33}290 we AZ|MSUconpcieasMOMISey-864y ms " re xi,.700/12001 DWG apo 6-37 |icy gl sae ve WOM ya wt 2p \!rn vax 41MAA-o-!La Gat:tex 1/02 gx 2708 !!vex IAC ipa M173 cx 2A 30K 9 17 u Mount a vee 2pm v4p13 1293 gaa _pele?aweodLconsTRUCRONNOTE12tage971798ewn_RELIG CONSTRUCTION WOTE +4 apex i ap 1 (wg 2p 2/xd|it La------4 apn 2g area Tis |2fuyPay,Eu |ww "1peekyalaé7 ¢ |ay ver,aisle +rs 11 26 ver zyl_snp ey |J {ez6104 5 |5:' 1 LES 6 DSS + an n . Yue CONSTRUCTION NOTE 1 1,MEA TO VERE:'SED ON RELAY SETTINGS.CONSTRUCTION NOTE 1 saa 3pdie3Aa LEGEND(©TERMINAL BLOCK Wt THE RELAY/CONTROL/WARSHALLING CABINETvewp<sorme tum aon room emname omer |SSUEDFORBIDONLY 1g !2K Mt /0M6 vay ©DEWCE TERMINAL -_-vey _¥1/DN2 FELO CQUPMENT TERIANAL42pxMAN?vey »cy OS i wA_20 tw N20 2pex 1 7oMB iy wei ADns an ae weer ae .TEELAND BYPASS SUBSTATION ENG.STAMP Toa:NO,|ORAWNG NO./SMEET REFERENCE DRAWNG/DETAIL/PLAN/SECTION DESCRIPTION DRANG NAME:Taeewee/rRo.ect enawece,KR.GOIS/S,NORCESTER,STANLEY CONSULTANTS soap Matanuska ElectricA Tatas th-arov Sea BS Wee Be Soe TEELAND BYPASS SUBSTATION No.DES ON/CONSTRUCTION/ASBUILT REV SION DWA BY/DATE REVEWED BY/DATE 138KV/115KV «SSUrO FOR CUENT RECw RO BARRY PSC OF 770715 R_EPSTN/SC)09/05/71 $ee TE or eae THREE-LINE AC SCHEMATIC feyMEA"===f Saves is (907)781-8300SARTANLISIKAELECTING'WW MEA COOP CAARING WO:NTSS-EL-0100 fee tot CONTIIED. (ON SHEET 1 ON SHEET T LEGEND Zo DISTANCE RELAY"=24 =VOLTS HERTZ3S=SYNC CHECK RELAY 27 UNOERVOLTAGE RELAY 43.=UANUAL TRANSFER OR SELECTOR DCWOE SO.=ISTANTANEOUS OVTRCURRTHT RELAY;B15 PMASF.TE OVTRCURRENT RELARPENT RELAY meme /ar HOD,CVT93ScovtTOOTHVAIS.6V-06.49ns 700/1200:1»He 10 SCADA PORER AUTOTRANSFORMER WO,t (11) TE 2 T3BKV/1T KYNo' 1200/SMA 1200/SMR 1200/50R 7B/N00/125 WVAB00800WETERING °fp--=to Scapa udNO"TOMIS62CF(sent1)Towize2cr(SHEET1}3zPEste!zazzza1200/5MR -1200/3uRcao00AMamwrse 16004 COWUNCA ELECTRICAL ENCLOSURENSoapereanswtihonaSmCeroScapaNON-LOADOREAK.SWITCH oeTO ENET SWITCH 1200/5Se frame case 3:¢2538ICLOSURE, WOUTAGLCowcctiow 10 BE OCODED DumNG10$0/620"-UT262P--(SHEET 5)10 $0/e70F-uTI962(sitet 1) F.0.10 EGSMTRSUBSTATION F utfw}4 wen wrze2 102 eaea.sofasn vwe wen wiser sco bzw -urzsa'50/620Fet382Ted Te t ' From (seer 1)==TO SCADA ro scan ee Byeroe-uraee50/6286 -MT362 SF FROM @KR MT362 CT (SHEET 1)= =BBS COL wonTOR FROM BER M1262 CT (S#6ET 1)BF 0/820 M1262 FROM ERR T2682 CT (SHEET oa ===TP BAR MTS62 TC?| ' ' ' 1 ' oneBFL 50/8ZFM1362 eavefomaesEeBens ISSUED FOR BID ONLY NOT FOR CONSTRUCTION proect,TEELAND BYPASS SLSUBSTATION ENG,STAMP ;- )on AE 7 ersOESCAER/oRO.eCT ENGnece,RB,GOIS/S.WORCESTER,STANLEY CONSULTANTS sosp Matanuska Electric Association Or ae tEAM DES TON TEELAND BYPASS SUBSTATION i i NO.Ot SIGN /CONS TRUC TION/ASBUILT RE VISION DWN BY/DATE REVIEWED SY/DATE MISS-EL-00n1 AL 120/240 VAC STATION SERVICE ONE-LINE DIAGRAM 138KV/1 15KVEmBSeRTNAGoeIPTwiSS=£1-0020/1 ARCHITECTURE OME-UNE OAGRAW ONE-LINE DIAGRAMSSLEDFORCONTRO,ENCLOSURE_BD A Bann (50 O9/nAS ME 4Aih ar Oey, MAATANUSKA ELECTRIC ASSOCIATION WWW MEA.COOP eae a MTSS-EL-0010 bee 2 6 2 ans»22 ¥$2,eetFa:5 BS 2 3 iewrase|=308 TO SCADA-#-4>To SCADA-+-4k ay scant 4 '' wore 2 MT262.-NOTE 2 wort 2 M1462 Nor.2 200s 1200/wn ieorsm "Zocor SPOOFS 1200/8R 1200/sumTeelSR1200/5 20008 1200,9200/5M8 1200/3MR 1200/5MR «1200 /SMR 1200/5 20004,1200/5MR 1200 SMR 1200/30 1.i:nS Oc CR ee wn:OO Cl eS a:Oc OS COR18004foawerfoowalfaawet16004-16004 ma faowat val I}faves!AM,yavasre >falee'reVaa)favaey 10 TO-w™m .>>To ame 10 T0-wm (SHEET 2)72)3 Hi (S47 2)(SHEET 2) 7 ie S558 S58ge8gee @®)Sst ae a$8 HYPanerZEAzeConTeED ON SHEET 2 BOF AT 362 H M1262 shecer-w1Z62 H Om SET 2 8608-452 Bog.M1382 3S psa 1362 Fg. TEs fe corp Ses Fie180°se ilies Sooc-¥?TBO -$SCADA "kboc-sostiemSSyo/s7er -ur NS cone onto stoKeen's PSYAC CHECK (25)50/875 -WT287 1a tal 50/8207 7382 N+NON-LOAD BREAK SWITCH 'SINC CHEOH (25)piszes SYNC CHECK (25) AUR *pseaoa aR ++eto Ener swroH eM rcs |TE am Sesacs|. é mes x ex(6u"10102 - se an 2s{our ios an 4 Rind Beteane cage OeSYNCCHECKORM1282XRashcoolantssuey 10 vem.te]ut vt!ont vat;, eee gaa +egretonioLs i or é 4 1 ALAR --opf--i010SCADAz||=>E=S A! 2!O-;£180 t ,BRR W262 TC!MOAR TOR Tec --BRR MTS62 1C1 MOTOR5QaTESaiertawenxmraga101"tet wise?102 wouter =88BF-uT782 COL WoTOR "ORR VTAS2 TCZ MOMTOR =WeBF-W1362 COL MONITOR 3 Grey '-M1462 COL MOMTOR 'sinbsSi =${act 2) <a(es --=EETSuatar senneeT0 SCADA am cu F.0.TO TEELAND FO TO TEELAND FO.TO DOUGLAS:aout261 oy 'SUBSTATION (DTT)77 SUBSTATION (OTT)*"-*SUBSTATION (DTT)rout 20 8£0 10 TEELAND Fo to mecLaNo Fa,To DOUGLAS i- Satoh estan corn iceeat!i stance (1D ee es 5 £0.10PRASTRSUBSTAINONFORAS,USent I uGTY SoOSTATON in TR BRR WTSEZ 102 fra]os ane TO SCADA ae <BR 80/820"-M7382ra]<+-eTo ener suitor ++ero pect smton eRe mee wr482 102 ----8 -G-8 on 2 'aod fect reteTRE ORR MI262 TCH t ==TRE BRR WT262 107 1 ' on 2a|o4 wt aanOF 80/8208 -U1262 |ato aneee eee:OF)50/8287 M1262 |OF 50/820F-7362outms 'helaSRP BKR MT482 TCI =TR BRR MT4A2 TC TIP ORR MT402 TCL \UT 4 i)nn feepecee eee BF 50/828F-MT482 anf benponeeceee OF!30/47OF -uT482 OF 90/620 -UTA62 |at as Tasa0ff--}------->=BLO CLOSE OK T2867 |"P|secsenee BLOCK CLOSE BKR W262 |alae aut 28 I\wo filaeeeneOOK CLOSE Own 462 \at =PLOCK CLOSE OxR wT482 'oat 208 7 Ri-amH) 1 f 1 FE ! 1 1 )OR Wrage 'at sn ese:|YOU SOS ates |Neoecurses |Bafana FR TE -i t M269 i] -_a -urzeo &SANT) ISSUED FOR BID ONLY NOT FOR CONSTRUCTION _t113 eroxct;TEELANDBYPASS SUBSTATION ENG.STAMP 5 call NO]_DRAWNG NO./SHEET REFERENCE DRAWNG/DETARPLAN/SECTION DESCRIP NON Sates wo Recesowreoxcrconere_ea,BR.GOIS/S,WORCESTER,STAN PTANTS 09 p Matanuska Electric Association Steeaaye tat lew buon TEELAND BYPASS SUBSTATIONOFSIGN/CONSTRUCTION/ASBUILT REVISION DWN BY/DATE REMEWED BY/DATE 2 |WISS-EL-0020/1 ONE-UNE DrAGRAMe 13BKV/1 15KV A]Swed Fon CUNT ROVE BBARRY SCI 06719713 PRUE SCI OF 0715 = 3]Sento For coe NCEE BD Taae a Te pe ONE-LINE DIAGRAM wayMEoe _{907}781-9300MATANUSKABLICTRICASSOQATION«=»:WWW.MEA.COOP Trae we MTSS-EL-0010 [xan o 2 IOC /Operator Report 1/5/2016 1.Alaska Intertie Status Report a.2015 MWH Usage at Douglas Substation i.First quarter:142,077 MWH ii.Second quarter :118,397 MWH iii.Third quarter:93,528 MWH iv.Fourth quarter:106,069 MWH v.2015 Total:460,071 MWH 2.System operation a.See attachmentA b.Alaska Intertie tripped with 30 MW's flowing north Wednesday 12/30/15 at 0558 -Trip coincides with MEA's 115kV line tripping between Teeland Sub and Hospital sub.Douglas breaker 138-B1 was closed at 0606. 3.Compliance Report a.None 4.Alaska Intertie SVC update a.Teeland,Healy and Gold Hill SVC in service. i.Crews Scheduling installation of new exhaust louvers to minimize coal dust entering the control building. 5.Intertie Operating Committee a.develop new spinning reserve allocation and reconcile standards between the IMC and RRO Reliability Standards.Update provided to IMC. b.Work with EPS and Henri Dale to revise/add the following Railbelt Reliability Standards. i.AKBAL-002 Disturbance Control Performance ii.AKTPL-001 thru 4 Transmission Planning iii.PRC-006 Automatic underfrequency load shedding c.Review additional balancing,Protection,Facility and Reserve Standards. 6.Machine Ratings Subcommittee a.Update MRSC online data base 7.Operations,Maintenance and Scheduling Subcommittee 8.Dispatch and System Operations Subcommittee 9.Budget Subcommittee 10.Engineering,relay and Reliability Subcommittee a.Technical review of MEA's proposal for a Teeland bypass. b.Review Douglas Substation Protection Upgrade Project 11.System Studies Subcommittee a.UFLS Study 12.SCADA and Telecommunications Subcommittee a.Review and make recommendation -SLMS communication upgrade proposal provided by EPS. Alaska Intertie Adopted FY16 Budget Proposed FY16 Budget REVENUES GVEA 1,346,724 ML&P 171,819 CEA 189,481 MEA 274,899 INTEREST TOTAL REVENUES 1,982,923 EXPENSES FERC 562 -Station Operation Expenses GVEA -Substation Electricity Usage 7,000 |Per GVEA 7,000 FERC 566 -Miscellaneous Transmission Expense Private Line Telephone Service for AKI SCADA (GVEA)100,000 |Per GVEA Cell Phone Comm.Svc for Weather Monitoring (ATT)15,000 |Per AEA SLMS Support and Intertie Ground Patrol 75,000 |Per AEA 190,000 FERC 567 -Transmission Expenses -Rents Rents -Alaska Railroad 700 |Fixed MEA -Talkeetna Storage 7,200 |Fixed 7,900 FERC 569 Maintenance of Structures MEA -Maintenance of Structures 10,000 |Per MEA GVEA -Re-level Structures &Adjust Guys 26,000 |Per GVEA 36,000 FERC 570 -Maintenance of Station Equipment 'GVEA -Healy,Cantwell,Goldhill 85,000 |Per GVEA GVEA -SCADA Maintenance Healy,Cantwell,Gold Hill 10,000 |Per GVEA MEA-Replace Protective Relay Schemes Douglas 325,000 |Per MEA CEA -Teeland Substation 161,000 |Per CEA MEA -Douglas Substation 10,000 |Per MEA 591,000 FERC 571 -Maintenance of Overhead Lines GVEA -Northern Maintenance 80,000 |Per GVEA GVEA -Northern ROW Clearing 50,000 |Per GVEA GVEA -Landing Pads 50,000 |Per GVEA GVEA -Repair Tower 692 10,000 |Per GVEA MEA-Special Patrols [Incl Foundation Inspections]40,000 |Per MEA MEA -Southern Maint (Incl Ground Inspect)50,000 |Per MEA MEA -Southern ROW Clearing 65,000 |Per MEA MEA -TWR 195 Repair Monitoring 10,000 |Per MLP 355,000 FERC 924 -Property Insurance AK intertie -Insurance 145,000 |Incl.aviation insurance 145,000 Intertie Operating Costs Total 1,331,900 FERC 920 -AEA Administrative Costs Personal Services,Travel and Other Costs 50,000 |Per AEA $0,000 FERC 920 -IMC Administrative Costs IMC Administrative Costs (Audit,meetings,legal)50,000 |Per IMC Chair 50,000 FERC 566 -Miscellaneous Transmission Expense Misc Studies as needed,(including Under Frequency Load Shed Study UFLS &450,000 |MLP -administrativeReliabilityStudy) 450,000 Intertie Administration Costs Tota!550,000 TOTAL EXPENSE 1,881,900 SURPLUS (SHORTAGE)101,023 Alaska Intertie Amended FY16 Budget Amended FY16 Budget REVENUES GVEA 1,371,724 ML&P 196,819 CEA 214,481 MEA 299,899 INTEREST TOTAL REVENUES 2,082,923 EXPENSES FERC 562 -Station Operation Expenses GVEA-Substation Electricity Usage 7,000 |Per GVEA 7,000 FERC 566 -Miscellaneous Transmission Expense Private Line Telephone Service for AKI SCADA (GVEA)100,000 |Per GVEA Cell Phone Comm.Svc for Weather Monitoring (ATT)15,000 |Per AEA SLMS Support and Intertie Ground Patrol 75,000 |Per AEA 190,000 FERC 567 -Transmission Expenses -Rents Rents -Alaska Railroad 700 |Fixed MEA-Talkeetna Storage 7,200 |Fixed 7,900 FERC 569 Maintenance of Structures MEA -Maintenance of Structures 10,000 |Per MEA GVEA -Re-level Structures &Adjust Guys 26,000 ]PerGVEA 36,000 FERC 570 -Maintenance of Station Equipment GVEA -Healy,Cantwell,Goldhill 85,000 |Per GVEA GVEA -SCADA Maintenance Healy,Cantwell,Gold Hill 10,000 }Per GVEA MEA -Replace Protective Relay Schemes Douglas 325,000 |Per MEA CEA -Teeland Substation 161,000 |Per CEA MEA -Douglas Substation 10,000 |PerMEA 591,000 FERC 571 -Maintenance of Overhead Lines GVEA -Northern Maintenance 80,000 |Per GVEA GVEA -Northern ROW Clearing 50,000 |]Per GVEA GVEA -Landing Pads 50,000 |Per GVEA GVEA -Repair Tower 692 10,000 |PerGVEA MEA-Special Patrols [Incl Foundation Inspections]40,000 |Per MEA MEA-Southern Maint (Incl Ground Inspect)50,000 |Per MEA MEA-Southern ROW Clearing 65,000 ]Per MEA MEA -TWR 195 Repair Monitoring 10,000 |Per MLP 355,000 FERC 924 -Property Insurance AK Intertie -Insurance 145,000 |Incl.aviation insurance 145,000 Intertie Operating Costs Total}1,331,900 FERC 920 -AEA Administrative Costs Personal Services,Travel and Other Costs 50,000 |Per AEA 50,000 FERC 920 -IMC Administrative Costs IMC Administrative Costs (Audit,meetings,legal)50,000 |Per IMC Chair 50,000 FERC 566 -Miscell us Transmission Exp Misc Studies as needed,(including Under Frequency Load Shed Study UFLS &450,000 |MLP -administrativeReliabilityStudy) Reliability Standards Update (EPS/Hdale inc.)100,000 550,000 intertie Administration Costs Total 650,000 TOTAL EXPENSE 1,981,900 SURPLUS (SHORTAGE)101,023 Alaska Intertie Quarterly Report through September 30 2015 Amended Actuals FY16 as of (OVER) Budget 09/30/2015 UNDER REVENUES GVEA 1,371,724 726,650 645,074 ML&P 196,819 68,694 128,125 CEA 214,481 81,060 133,421 MEA 299,899 100,211 199,688 INTEREST 98 TOTAL REVENUES 2,082,923 976,714 1,106,308 EXPENSES FERC 562 -Station Operation Expenses GVEA -Substation Electricity Usage 7,000 833 6,167 |PerGVEA 7,000 833 6,167 FERC 566 -Miscellaneous Transmission Expense Private Line Telephone Service for AKI SCADA (GVEA)100,000 12,190 87,810 |Per GVEA Cell Phone Comm.Svc for Weather Monitoring (ATT)15,000 3,177 11,823 |Per AEA SLMS Support and Intertie Ground Patro!75,000 -75,000 |Per AEA 190,000 15,367 174,633 FERC 567 -Transmission Expenses -Rents Rents -Alaska Railroad 700 -700 |Fixed MEA-Talkeetna Storage 7,200 1,800 5,400]Fixed 7,900 1,800 6,100 FERC 569 Maintenance of Structures MEA -Maintenance of Structures 10,000 -10,000 }Per MEA GVEA -Re-level Structures &Adjust Guys 26,000 -26,000 |Per GVEA36,000 -36,000 FERC 570 -Maintenance of Station Equipment GVEA -Healy,Cantwell,Goldhill 85,000 18,013 66,987 |Per GVEA GVEA -SCADA Maintenance Healy,Cantwell,Gold Hill 10,000 4,007 5,993 |PerGVEA MEA-Replace Protective Relay Schemes Douglas 325,000 -325,000 |Per MEA CEA -Teeland Substation 161,000 6,494 154,506 |PerCEA MEA-Douglas Substation 10,000 -10,000 |Per MEA 591,000 28,514 562,486 FERC 571 -Maintenance of Overhead Lines GVEA -Northern Maintenance 80,000 13,673 66,327 |PerGVEA GVEA -Northern ROW Clearing 50,000 13,209 36,791 |PerGVEA GVEA-Landing Pads 50,000 -50,000 |Per GVEA GVEA -Repair Tower 692 10,000 -10,000 |PerGVEA MEA-Special Patrols [Incl Foundation Inspections]40,000 -40,000 |Per MEA MEA -Southern Maint (Incl Ground Inspect)50,000 435 49,565 |PerMEA MEA-Southern ROW Clearing 65,000 -65,000 |Per MEA MEA -TWR 195 Repair Monitoring 10,000 :10,000 |Per MLP 355,000 27,317 327,683 FERC 924 -Property Insurance AK Intertie -Insurance 145,000 74,587 70,413 |Incl.aviation insurance 145,000 74,587 70,413 Intertie Operating Costs Total 1,331,900 148,418 1,183,482 FERC 920 -AEA Administrative Costs Personal Services,Travel and Other Costs 50,000 6,774 43,226 |Per AEA 50,000 6,774 43,226 FERC 920 -IMC Administrative Costs IMC Administrative Costs (Audit,meetings,legal)50,000 3,359 46,641 |Per IMC Chair50,000 3,359 46,641 FERC 566 -Miscellaneous Transmission Expense Misc Studies as needed,(including Under Frequency Load Shed Study UFLS &450,000 38,232 411,768 |MLP -administrativeReliabilityStudy) Reliability Standards Update (EPS/Hdale Inc.)100,000 100,000 550,000 38,232 411,768 Intertie Administration Costs Total 650,000 48,364 551,636 TOTAL EXPENSE 1,981,900 196,782 1,785,118 SURPLUS (SHORTAGE)101,023 779,932 (678,909) ALASKA INTERTIE MANAGEMENT COMMITTEE MEETING Tuesday,Jan 5,2016 -9:00 AM **PLEASE WRITE LEGIBLY** NAME Organization Bequie SpvZA/GUGLIC Gey Vuh MEA Ec Jenkin pA Err tue (Gllespre AQCTES Be Dy (Rieaase COoest) Tory Ltr ME/)7 lvrlee Usk L hustle Lh Aty Cer loa Cle',get Gen Secon MCE.e Monica Grassi GVEA KR GiIBSQV MNQoucll ,Qa dds +Glad poQownUeindersaynUVP Bryan 34DAYD Wm po SUNS QV. Teri Webster From: Sent: To: Subject: OpenVoice <DO.NOT.REPLY@citrixonline.com> Tuesday,January 05,2016 11:55 AM Teri Webster OpenVoice Conference Information # -Important OpenVoice Notification # OpenVoice & Dear Teri Webster, The following is a summary of a conference you held. Information in this report is based on the time zone setting on the My Account page. Date of conference call:01/05/2016 Conference Room #:467050126 Conference Call Detail Report: [Catling Party$|Called Number |BY Billed AS¥e |start times |i +19073229228 |18885859008 US Toll-free 09:57 AM PST 56 +19072243331 |18885859008 US Toll-free 10:02 AM PST 52 +16088777608 |18885859008 US Toll-free 09:56 AM PST 58 +19077713994 |18885859008 US Toll-free 09:55 AM PST 59 Visit My Conferences to see your minute usage. Total Minutes:225 NumberofCallers:4 If you have any questions,please contact Global Customer Support. Thank you for using OpenVoice Audio Conferencing. Regards, Global Customer Support http://support.citrixonline.com/OpenvVoice Join audio conferences instantly with the free OpenVoice mobile app. One-tap simplicity -no need to type in phone and conference room numbers. ¢%Download on they&AppStore - -GETITON qe p>Google play PME Cag AMER SG Soe ET INTERTIE MANAGEMENT COMMITTEE FORM OF DESIGNATION OF REPRESENTATIVE AND DESIGNATION OF ALTERNATE REPRESENTATIVE [MATANUSKA ELECTRIC ASSOCIATION,INC.] In accordance with the Amended and Restated Alaska Intertie Agreement,Section 8.1,Establishment of Intertie Management Committee,Right to Vote,and the Intertie Management Committee ("IMC”) Bylaws,Article 4,REPRESENTATIVES,Matanuska Electric Association,Inc.,hereby designates the following persons as its representative and alternate representative to the IMC: Representative:Anthony M.Izzo tony.izzo@mea.coop Alternate:Gary Kuhn gary.kuhn@mea.coop Efechve Jan WU,201i Matanuska Electric Association,Inc. P.O.Box 2929 163 Industrial Way Palmer,AK 99645 Phone:(907)761-9212 Fax:(907)761-9368 ATTENDANCE -IMC Jan 5,2015,9:00 am | |Phone |COMMITTEE MEMBERS oo ALTERNATE | |Brian Hickey CEA |Burke Wick | A Jeff Warner ;MLP Mark Johnston "7!Kirk Warren,Secretary/Treasurer AEA |Sara Fisher-GoadWeCoryBorgesonGVEA|Allen Gray /Evan "Joe”Griffith,Chairman |MEA |Gary Kuhn | | | | Public Members COUNSEL /Bernie Smith ap irk Gibson,McDowell Rackner & V/Bob Day -HEA Gibson PC | ony Izzo ;_Abtian Bjorkquist,Dept.of Law | |Bavid Gillespie -ARCTEC i;| 'David Pease -MEA |Dave Burlingame -EPS Karen Bretz -MLP | :Ed Jenkin -MEA AEA Staff Laie Cullum?Amencah Trensessinn Cd Jecelyn-Garrier Ow cm ala Teri Webster "MTS Ore Representative Kirk Warren Secretary/Treasurer Mark Johnston Chairman Brian Hickey Vice Chairman Cory Borgeson Tony !zzo Kirk Gibson ALASKA INTERTIE MANAGEMENT COMMITTEE List of Representatives Alternate Sara Fisher-Goad Jeff Wamer Burke Wick Allen Gray Gary Kuhn Revised Date:January 8,2016 Utility Alaska Energy Authority 813 West Northern Lights Boulevard Anchorage,Alaska 99503 Teri Webster's ph:771-3074 Fax:771-3044 kwarren@aidea.org sfishergoad@aidea.org Anchorage Municipal Light &Power 1200 East First Avenue Anchorage,Alaska 99501 Jeffs Ph:263-5282;242-7244 c Linda Davidovic's ph:263-5201 Fax:263-5204 johnstonma@muni.org warnerja@muni.org Chugach Electric Association 5601 Electron Drive Anchorage,Alaska 99518 Brian ph:762-4518 Connie Owens ph:762-4747 Fax:762-4514 Brian_Hickey@chugachelectric.com Burke_Wick@chugachelectric.com Golden Valley Electric Association P.O.Box 71249 Fairbanks,Alaska 99707-1249 Susan Redlin's ph:907-458-5721 Fax:458-5951 cborgeson@gvea.com ajgray@qvea.com Matanuska Electric Association P.O.Box 2929 (163 Industrial Way) Palmer,Alaska 99645-2929 Dawn Baham's ph:907-761-9285 Fax:761-9368 tony.izzo@mea.coop gary.kuhn@mea.coop McDowell Rackner &Gibson PC 419 SW 11"Street,Suite 400 Portland,Oregon 97205 Phone:(503)290-3626 Fax:(503)595-3928 Kirk@mcd-law.com ALASKA INTERTIE MANAGEMENT COMMITTEE AGENDA Tuesday,January 5,2016 9:00 a.m.-11:00 am Alaska Energy Authority,Board Room 813 W.Northern Lights Boulevard,Anchorage,Alaska 1.CALL TO ORDER 2.ROLL CALL FOR COMMITTEE MEMBERS 3.PUBLIC ROLL CALL 4.AGENDA APPROVAL PUBLIC COMMENTS no.4APPROVAL OF PRIOR MINUTES -December 2,2015 7.OLD BUSINESS AA.Reliability and Operating Standards (or B.Douglas substation upgrade proposal --MEA XA.Teeland Bypass substation proposal -IOC 8.NEW BUSINESS A.Election of Chairman 9."IOC /OPERATORS REPORT -ML&P/GVEA 10.BUDGET COMMITTEE UPDATE 11.COMMITTEE ASSIGNMENTS 12.NEXTMEETING DATE 1/3.yorkchep 13.ADJOURNMENT To participate via teleconference,dial 1-888-585-9008 and use conference room code 467 050 126 Intertie Management Committee Meeting -Alaska Online Public Notices Page 1 of 1 STATUS:Active Intertie Management Committee Meeting ALASKA ENERGY AUTHORITY Regular Meeting Intertie ManagementCommittee The Intertie Management Committee will holda meeting on Tuesday,January 5,2016 at 9:00 a.m.For additional information contactTeri Webster at (907)771-3074. This meeting will be conducted byelectronic media pursuant to AS 44.83.040(b)and AS 44.62.310 at the followinglocation: Alaska Energy Authority Board Conference Room 813 West Northern LightsBoulevard Anchorage,Alaska A teleconference line has been set up forthose unable to attend in person.Dial1-888-585-9008,Enter conference room 467 050 126. The public is invited to attend.The Stateof Alaska (AEA)complies with Title I]of the Americans with Disabilities Actof 1990.Disabled persons requiring special modifications to participate shouldcontact AEA staff at (907)771-3074 to make arrangements. Attachments,History,Details Attachments Details IMC Agenda -1.05.16.pdf Department:Commerce,Community andEconomicDevelopment Revision History 'Category:Public Notices Created 1/4/2016 10:00:19 AM by tawebster Sub-Category:Advisory Committee Meeting Location(s):Statewide Project/Regulation #: Publish Date:1/4/2016 Archive Date:1/5/2016 Events/Deadlines: https://aws.state.ak.us/OnlinePublicNotices/Notices/View.aspx?id=179650 1/4/2016 Intertie Management Committee Regular meeting MEETING MINUTES Wednesday,December 2,2015 Anchorage,Alaska 1.CALL TO ORDER Chair Joe Griffith called the meeting of the Intertie Management Committee to order on December 2, 2015 at 9:31 am.A quorum was established. 2.ROLL CALL FOR COMMITTEE MEMBERS Brian Hickey Chugach Electric Association (CEA) Cory Borgeson Golden Valley Electric Association (GVEA) Joe Griffith Matanuska Electric Association (MEA) Kirk Warren Alaska Energy Authority (AEA) Jeff Warner Anchorage Municipal Light &Power (ML&P) 3.PUBLIC ROLL CALL Burke Wick (CEA);Gary Kuhn,Ed Jenkins,Tony Izzo,David Pease (MEA);Kirk Warren,Teri Webster (AEA);Mark Johnston,Karen Bretz (ML&P);Mark Johnson (CEA);Allen Gray (GVEA); Bob Day (Homer Electric Association (HEA));Kirk Gibson (McDowell Rackner &Gibson PC); Brian Bjorkquist (Dept.of Law);Dave Gillespie (ARCTEC);Dave Burlingame (EPS);Henri Dale; and Bernie Smith. 4.AGENDA APPROVAL MOTION:Mr.Borgeson made a motion to approve the agenda as presented.Motion seconded by Mr.Hickey.The agenda was adopted without objection. 5.PUBLIC COMMENTS None 6.APPROVAL OF PRIOR MINUTES -October 16,2015 MOTION:Mr.Borgeson made a motion to approve the prior minutes of Oct.16,2015.Motion seconded by Mr.Hickey.The motion was approved unanimously. 7.OLD BUSINESS 7A.Review of Reliability Standards integration proposals from EPS and Henri Dale The committee reviewed the two proposals from EPS and Henri Dale,LLC.Updating the reliability standards will be a joint effort between the two.Initial focus will be on the Balancing Standards and the underfrequency load shedding system.Mr.Dale's previous and ongoing work of combining the Regional Reliability Organization (RRO)and IMC standards will not be effected and were not a part of this recent proposal submission. One major item lacking in the standards are established measurables that they both have been instructed to incorporate. The final version is due by the end of December in order to present to RCA by the time they open the reliability standards 1/1/16. IMC Meeting Minutes-December 2,2015 Page 2 of 3 MOTION:Mr.Borgeson made a motion to approve a combined $100,000 to amend and update the Reliability Standards from EPS and Henri Dale,LLC.Motion seconded by Mr.Hickey.The motion was approved unanimously. 7B.Spin Requirements --IOC Recommendations There has been an agreement on the allocation of the spin requirements and all of the standards.The documents are currently being reviewed by all the participants and expect only a few edits.It should be in final form in a week. Mr.Griffith noted that the IMC is the in house keeper of the reliability standards and spin requirements.The IOC is the technical knowledge behind it.It is a living document. 7C.SVC Warranty Policy update Mr.Warren presented the offer from Alstrom for a five-year term contract plus a three-year warranty. The warranty will cover spare parts.The one million contract includes 24/7 telephone support and training and maintenance in year one and five with an assessment on year three.Since this was a sole source procurement,the Department of Transportation needs to review and approve the sole source. It is expected to be approved within a week. MOTION:Mr.Borgeson made a motion that all the utilities support the decision to go with this sole source procurement.Motion seconded by Mr.Hickey.The motion was approved unanimously. 7D.Douglas substation upgrade Discussed getting guidance to use the existing appropriation originally appropriated for the extension of the intertie.A formal proposal from the IMC is needed stating the need and the scope of work. MEA will present the proposal at the next meeting. 8.NEW BUSINESS 8A. Teeland Bypass substation approval -MEA Mr.Kuhn presented the proposal for MEA to construct a new substation to directly connect MEA's 115kV transmission system to the IMC controlled 138kV line between Teeland and Douglas substation. There was no motion. 9.REPORTS 9A._Intertie Operating committee report /Operators Report Mr.Warner gave the Operators and IOC reports. Mr.Johnston gave an update on the recovery of the ML&P worker who was shocked in October.His recovery is going well and a full recovery is expected.A GoFundMe account was set up to help with medical expenses and with donations from all the utilities 24K was raised. 9.COMMITTEE ASSIGNMENTS e MEA isto bring a formal proposal for the Douglas substation upgrade to the next meeting. e The Budget committee is to give an update at the next meeting. IMC Meeting Minutes-December 2,2015 Page 3 of 3 ¢IOC is to look at the technical aspect of the Teeland Bypass proposal using the IMC adopted Transmission Interconnection Standards and bring it back to the committee. 10.NEXT MEETING DATE Call of the chair.Mr.Griffith would like the next meeting to be held before his retirement on January 8,2016. 12.ADJOURNMENT mayeniw business gf the IMC,the meeting adjourned at 10:50 a.m.Ld KijeWVarren,Secretary To obtain an audio of the full meeting,contact Teri Webster (AEA)at 907-771-3074.