HomeMy WebLinkAboutWater Sewer Summary PageWater & Sewer Estimated Energy Use The attached documentation presents an estimate of energy use as found in water and sewer systems throughout Alaska, including large water and sewer systems in the railbelt and southeast Alaska and rural Alaska Water and Sewer Systems. • Large Alaska Water and Sewer Systems. The energy data, as found in the Large Alaska Community Water and Sewer table, was collected in January/February 2012. An energy specialist contacted the engineering and billing departments in the respective utilities. Actual data was included for those utilities that provided the information. For those utilities that did not provide data or provided incomplete information, estimates were made based upon comparably sized utilities with some adjustments based upon community served and population. The adjustments are noted in the tables. Energy estimates were made based upon the data provided. • Rural Alaska Water and Sewer Systems. Alaska Native Tribal Health Consortium, Division of Environmental Health and Engineering, provided a listing of all rural Alaska communities served by piped water and sewer. Septic systems and haul systems are not included in this analysis. The results of the water and sewer energy models for New Stuyahok, Savoonga, Selawik, and Bethel were used as comparable communities. For each community found on the water and sewer master list, adjustments were made based on the number of occupied homes as it compares to the energy model. Therefore, occupied homes in both the comparable communities and the water and sewer system communities were used as the unit of analysis. The energy outputs from the energy model were used as proxy data. The estimates for the water and sewer energy use can be found in the following pages. We are estimating this at a +/45% level of accuracy. Water & Sewer Estimate Water and Sewer Energy Use Power (MMBtu) Heat (MMBtu) MMBTU/YR Estimate for all water and sewer systems in AK Total population % of total by population % of total by MMBTU/YR Large Community Water & Sewer 131,937 128,137 260,074 403,568 87.92% 61.30% Rural Water & Sewer Communities 25221 138996 164,216.39 55,449.00 12.08% 38.70% Total MMBTU/YR 157157 267133 424,291 459,017 100.00% 100.00% Notes Rural Water and Sewer systems was derived upon ANTHC reports on total water and sewer systems No septic s systems or haul systems were included in this analysis Estimates were based upon modeled energy use for comparable communities Actual data was collected for Alaska's top ten communities by population Rough order of magnitude energy estimate (+/-50%)