HomeMy WebLinkAboutCESA - Program Evaluation_Jun_2011
About Clean Energy States Alliance
Clean Energy States Alliance (CESA) is a national nonprofit organization located in Montpelier, Vermont. It is the
only organization that represents the collective voice and interests of the public clean energy programs in the
United States. CESA serves as a forum for peer-to-peer learning and collective problem solving among the
leading public clean energy programs. CESA also provides assistance on clean energy program design, finance
and evaluation to all 50 states. Since 1998, CESA members have invested more than $2.7 billion dollars through
grants, rebates, loans and other investments in over 74,000 clean energy technology projects and companies,
while leveraging over $9.7 billion in additional investments. For more information about CESA, its programs and
its members, please visit www.cleanenergystates.org.
Evaluating
Renewable Energy
Programs
A Guide for Program Managers
Prepared by
Warren Leon
Senior Advisor
Clean Energy States Alliance
June 2011
Table of Contents
Introduction: The Case for Evaluation and for this Report ............................................................. 1
1. Types of Evaluations ................................................................................................................... 3
2. Preparing for Effective Evaluation .............................................................................................. 5
2.1 Set Appropriate Program Goals ....................................................................................... 5
2.2 Produce a Program Theory and Logic Model ................................................................... 5
2.3 Create and Implement a Monitoring Plan for Each Program .......................................... 7
2.4 How to Choose Which Evaluations to Do ........................................................................ 8
2.5 Have Clear Evaluation Goals ............................................................................................ 8
2.6 How to Select Evaluators and Get the Most from Them ................................................. 9
3. Recommendations for the Five Types of Evaluation ................................................................ 12
3.1 Needs and Market Assessment Studies ......................................................................... 12
3.2 Process Evaluations ........................................................................................................ 12
3.3 Outcome Evaluations ..................................................................................................... 14
3.4 Impact Evaluations ......................................................................................................... 23
3.5 Cost-Benefit Evaluations ................................................................................................ 26
4. Framing and Presenting Evaluations for Audiences outside Your Agency ............................... 32
APPENDICES .................................................................................................................................. 34
Appendix A: Developing a Program Theory .................................................................................. 35
Appendix B: Sample Program Logic Model ................................................................................... 36
Appendix C: Possible Evaluation Questions .................................................................................. 38
Appendix D: Description of Models Used in Cost-Benefit Evaluations ........................................ 43
Appendix E: Reference Works ...................................................................................................... 47
Appendix F: Representative Evaluation Reports .......................................................................... 49
Acknowledgments......................................................................................................................... 53
││
Introduction: The Case for Evaluation and for this Report
Some state clean energy programs have implemented impressive evaluations of their initiatives but
not all evaluations end up being perceived as valuable by program managers or stakeholders. This
report considers evaluation from the perspective of the program manager. It suggests how to ensure
that evaluation activities are useful, cost-effective, and well-received by program staff, policymakers,
and stakeholders. It recommends how to approach and choose among different types of
evaluations.
The report can serve as an introduction to evaluation for a new program manager of a recently
established renewable energy agency but will also provide useful information and ideas for more
experienced program managers and established agencies.
* * *
Evaluation is an essential part of good program management. When approached carefully and
done well, it can significantly improve the quality and efficiency of a renewable energy program.
It can also provide managers and stakeholders with a better understanding of what the program is
accomplishing, and how those accomplishments compare to those of other programs. In addition,
by making evaluation an integral part of program development and management, agencies demon -
strate that they take their responsibilities seriously and are seeking to maximize the public benefits
of public spending.
Even though most managers of state clean energy funds and agencies know that evaluation is
important, there are several reasons why evaluation s of renewable energy programs do not always
end up being entirely successful:
1. Evaluation may not receive enough attention. Renewable energy program directors and
managers usually have grueling workloads and many conflicting demands on their time. In their
desire to implement renewable energy rapidly, they sometimes have difficulty devoting resources
and time to evaluation. And even if the agency sets aside sufficient money for evaluation
studies, program managers may not focus sufficiently on what they want to accomplish with
those studies or may not put enough time or effort into working with the people hired to
produce evaluation reports.
2. There are relatively few widely accepted protocols for evaluating renewable energy
programs. In the clean energy program evaluation arena, energy efficiency has received extensive
attention, because state and utility energy efficiency programs have been in place for several
decades and regulators have had to develop clear measures of program impacts to determine
appropriate payments to utilities for energy efficiency activities. As a result, there has been
considerable exchange of evaluation strategies and methods among the various states and
evaluation contractors. In comparison, most renewable energy programs are newer, they vary
││
more in their programmatic goals and approaches, and they have not had as much experience
with evaluation.1
3. It can be difficult to evaluate the results of renewable energy programs. In some cases,
as with a program that aims to build a self-sustaining industry focused on a particular renewable
energy technology, the full impacts of the program may not be known for many years. In other
cases, such as with R&D grants, impacts can be hard to quantify. At other times, quantitative
data is available, but may be difficult to convert to easily defensible results (e.g., it may require
assumptions about energy prices far into the future or necessitate complex modeling of the
state’s economy).
4. The goals of renewable energy programs may not be explicit or fully thought out.
Program evaluators assess renewable energy programs in relationship to those programs’
objectives. Consequently, if program managers have not been explicit about what they are
trying to accomplish or if the articulated goals do not accurately reflect all of the program
managers’ expectations, it can be difficult to produce a satisfactory evaluation .
5. The decision about what to evaluate is not made by program managers. Regulators
or others overseeing renewable energy programs occasionally choose to evaluate a program
against a specific set of program objectives or standards that may not completely align with the
program managers’ goals for that program. For example, several funders have requested cost-
benefit analyses that look only at end-users’ direct financial savings from renewable energy
installations, and then compared those savings to ones from comparable energy efficiency
programs, even though the renewable energy program also had other important objectives,
such as building a renewable energy business cluster or improving the quality of certain
renewable energy products.
Despite these problems, there have been enough useful renewable energy evaluation reports and
enough evidence of the ways in which those reports have improved the performance of particular
renewable energy agencies to indicate that all renewable energy agencies should give significant
attention to evaluation. On the other hand, because there have been cases where agencies have
been unhappy with the quality of evaluation reports or have not found them useful, it is important
to proceed carefully in order to reap more of the potential benefits of evaluation. In an era of tight
budgets, it is especially important to use evaluation to make sure that renewable energy programs
have meaningful goals, are well designed, and are efficiently delivered.
1 As evidence of the relative maturity of energy efficiency evaluation versus renewable energy evaluation, the 2010
International Energy Program Evaluation Conference included well more than 40 presentations that were explicitly
about energy efficiency, but only one that focused on renewable energy. (There were also some presentations about
transportation and general topics, such as behavior change programs.) For the conference agenda and links to
individual conference presentations, see www.iepec.org/paris2010/Agenda.htm.
││
1. Types of Evaluations
According to the US Department of Energy’s Office of Energy Efficiency and Renewable Energy
(EERE), there are five different types of program evaluations:2
1. Needs and Market Assessment Evaluations identify target markets and seek to understand
a particular market or audience. They also identify and analyze barriers to the adoption of
renewable energy, establish market baselines, and explore customer needs. They can help
program managers design appropriate, effective programs and establish baselines that can be
used to measure future progress.
2. Process Evaluations examine program implementation processes and operations in order to
determine how to improve the program’s efficiency and effectiveness. They look at whether the
program is well-designed, efficiently managed, effectively marketed, and is producing satisfied
customers.
3. Outcome Evaluations determine the extent to which a program’s intended outcomes and
objectives are being achieved.
4. Impact Evaluations estimate the share of the outcomes that were the result of the program
rather than other influences. Because this type of evaluation factors out outcomes that would
have taken place anyway, the findings may be more meaningful than those produced by an
outcome evaluation, but they are also more difficult to obtain. [Some private sector evaluators
use the term “net outcomes” rather than “impacts,” and use the term “gross outcomes” for
evaluation type #3 above.]
5. Cost-Benefit Evaluations compare the value (generally financial) of a program’s impacts to
the cost of achieving those impacts. More elaborate cost-benefit analyses consider indirect
effects, such as the economic impact of changes to retail electricity prices or the indirect jobs
created by state spending on a major renewable energy installation. This type of evaluation is
often of particular interest to politicians, regulators, and board members who oversee state
clean energy agencies, but it can be difficult to produce precise results that are fully defensible
and invulnerable to criticism, especially when indirect economic effects are considered.
2 The material in the succeeding paragraphs is adapted from Harley Barnes et al., EERE Guide for Managing
General Program Evaluation Studies: Getting the Information You Need (Washington: US DOE, 2006), pp. 2, 9, 17;
available at http://www1.eere.energy.gov/ba/pba/pdfs/evaluation_mgmt_guide_final_2006.pdf. The EERE Guide is
a useful reference work for state clean energy program managers, because it offers a clear step -by-step approach for
how to plan, design, and manage a program evaluation. Although the recommended approach is sometimes overly
bureaucratic and aimed at federal program management needs, there is much useful information, some of which is
reproduced in the appendix to this report.
││
Table 1. Types of Evaluations
Evaluation Type What It Does Why It Is Used
Needs and market
assessment
Identifies target markets
Identifies barriers to the adoption
of renewable energy
Understand a market or audience
Help program managers
design programs
Establish baselines for
measuring future progress
Process evaluation Examines program
implementation processes and
operations
Determines whether the program
is well-designed, efficiently
managed, and effectively
marketed
Assess customer satisfaction
Identify ways to improve the
program
Understand the views of
customers and other
stakeholders
Outcome evaluation Determines whether the program
is achieving its intended
outcomes and objectives
Keep program managers
and others focused on the
program’s goals
Know whether a program is
achieving its objectives
Determine whether the
program should be modified
so that it is better achieving
its objectives
Impact evaluation Determines the share of the
outcomes caused by the program
rather than other factors
Identifies unintended but
valuable benefits of the program
Understand what the
program is actually causing
to happen
Determine whether the
program is unnecessarily
providing funding to free
riders who do not need
program to act
Cost-benefit
evaluation
Compares the economic and/or
other benefits of a program’s
impacts to the cost of achieving
those impacts.
Determine the extent to
which the program’s
benefits outweigh its costs
Understand whether the
program is cost-effective
Decide whether the program
should be continued as is,
modified, or ended
││
2. Preparing for Effective Evaluation
“Not everything that counts can be counted,
and not everything that can be counted counts.”
--Albert Einstein
The foundation for useful evaluation is laid at the initial development of a new program, well
before most evaluation activities begin. A program should have clear goals and there should ideally
be a program theory and logic model. Not only will goals, a theory, and a model help program staff
manage and implement the program, but they will help evaluators determine what to evaluate and
how. When program managers end up dissatisfied with an evaluation report it is often because the
program managers, evaluators, and the state authorizing body did not have the same understanding of
the program’s goals and how the program was supposed to achieve those goals.
2.1 Set Appropriate Program Goals
Program goals have a tendency to fall into one of two extremes that can leave out important
intentions and objectives of the program:
1. They can stop with simple quantitative targets. Although it can be desirable to know
that a program aims to “increase the solar capacity in the state by ten megawatts” or “provide
feasibility study grants to 100 businesses” or “distribute $10 million in rebates to municipalities,” it
is also important to articulate the underlying reasons for selecting those targets and what you
hope to accomplish by reaching those targets. For example, why is it meaningful to install ten
megawatts of solar? Is it simply because it starts to diversify the electricity supply or is it a
vehicle for expanding the solar installation businesses in the state, driving down the cost of
solar installations, increasing utilities’ comfort with distributed generation, and/or educating
the public about solar electricity? In the example above of feasibility study grants, what is their
purpose, what will successful completion of them lead to, and why is that important ?
2. They can be too vague. When a goal is as general as “build a wind industry in the state” or
“increase public awareness of biogas technology,” it is hard to know exactly what is intended or
if the program is being successful. For example, what specific type of wind industry will develop
because of the program and what will be its size and composition at specific points in time?
2.2 Produce a Program Theory and Logic Model
Once you have program goals, it is desirable to write a program theory, which links those goals to
the activities that will be necessary to achieve them. In fact, evaluators will generally want to see
and understand the program theory before they begin an evaluation. The California Evaluation
Framework, prepared for the California Public Utilities Commission, explains that “The program
theory describes, in detail, the expected causal relationships between program goals and program
││
activities in a way that allows the reader to understand why the proposed program activities are
expected to result in the accomplishment of the program goals.”3
The program theory is often placed into a graphical form and called a program logic model. This
model then becomes a visual representation of how the program is supposed to work. Although
program logic models have been around since the 1970s, they have become much more popular
over the past 15 years as evaluators, government agencies, and funders of nonprofits, most notably
the W.K. Kellogg Foundation, have promoted their use.
Program logic models can take many different forms and there is no single right one for all programs.
You should select a format that will be comfortable for your organization and seems to work well
for your programs. One caution is that there is a danger that a program logic model will become so
complicated that the eyes of program staff will glaze over, causing them to ignore the implications
of the model. Clear writing, color coding, and elimination of extraneous information can help
minimize this problem.
Many resources are available to help you choose among the possible formats and guide you
through the process of writing a model.4
A simple logic model can look like this:5
What is Invested What is done What Results
More elaborate models may distinguish between intermediate and final outcomes, or add in
additional categories, such as assumptions and market actors.6 The logic model ensures that the
program’s staff agrees on what the program will accomplish and how it will accomplish it. It is
especially important to develop a program theory and/or logic model when developing “complex
programs with long-term goals such as information and educational programs, and programs that
are trying to change how a market operates.” In these cases, “the program activities and the
desired long-term or ultimate outcomes of the program may be many steps removed from one
another.”7
One value of writing a logic model is that the exercise can reveal whether or not there really is a
logical, plausible, clearly defined route from the program’s activities to its final goals. Even if a
3 TecMarket Works, The California Evaluation Framework: Prepared for the California Public Utilities
Commission and the Project Advisory Group (Oregon, Wisc.: TecMarket Works, revised edition 2006), p. 31.
Available at www.tecmarket.net/documents/California%20Evaluation%20Framework%20Jan%202006.pdf .
4 In addition to The California Evaluation Framework, see, for example, the University of Wisconsin—Extension’s
online course and the W.K. Kellogg Foundation. Logic Model Development Guide described in Appendix E
(Reference Works).
5 Ellen Taylor-Powell et al., Enhancing Program Performance with Logic Models: An Online Course (Madison:
University of Wisconsin—Extension, 2002), p. 5 in section 1. Available at www.uwex.edu/ces/lmcourse/#.
6 The appendix includes an excerpt from The California Evaluation Framework on ―Developing a Program Theory,‖
as well as a sample program logic model from NYSERDA’s Clean Energy Infrastructure Program.
7 TecMarket Works, California Evaluation Framework, p. 36
││
program has been in existence for some time, it can be useful to go back and construct a logic
model that reflects how the program is actually operating. In such cases, a model can be developed
relatively quickly by program staff, especially for less complex programs.
Once developed, the program theory or logic model can help both program staff and evaluators
determine which issues and activities to evaluate. Evaluators can use the model to identify research-
able evaluation questions. The completed evaluation may uncover ways in which the logic model is
incomplete or inaccurate, and provide recommendations for how the logic model needs to be
modified. The evaluators should also distinguish “between theory failure (incomplete or inaccurate
theory), and program failure (poorly designed or implemented operational procedures).”8
As the EERE Guide for Managing General Program Evaluation Studies points out, “A logic model
should not be static. As the program matures, its logic model should be revisited at least annually
to check the assumptions embedded in its theory and to update it for lessons learned and changes
in its external environment.”9
2.3 Create and Implement a Monitoring Plan for Each Program
Monitoring, which is the collection of relevant measurement data, is an essential building block
of meaningful evaluation. Whenever a new program is added, a plan should be developed and put
into place to collect data related to the program. Ideally, the data collection plan should flow from
the program logic model. At the time a program’s logic model is written, there should be discussion
of the data that will be needed to measure whether the program is achieving its planned outputs,
outcomes, and inputs. While some of that data can be collected at the time of evaluation, some of
it must be gathered along the way or it will be lost or costly to recreate.
The monitoring plan should include information that directly reflects the agency’s activity (e.g.,
number of applications received, number of grants awarded, size of grants, geographic distribution),
as well as information that needs to be collected from grant recipients and others (e.g., cost of the
system purchased, installation company). When putting together the monitoring plan, it will often
make sense to find out what states with similar programs collect and how. To the extent that states
collect similar data in the same formats, it will be easier to make comparisons among states.10 It is
also often good to consult with an experienced program evaluator who can advise you on which
information is most likely to be useful for future evaluations and how to track that information in
formats that will be easy to analyze.
The collected data can end up being useful for more than its original evaluation purposes. To take
a simple example, information on solar rebate recipients that is collected to document whether the
program is meeting its goals in terms of number and size of solar installations can be re-analyzed to
find out whether some parts of the state are participating disproportionately in the program. You
should periodically look afresh at the data that has been collected by your agency to determine
whether it makes sense to use any of it in new ways. Because you already possess the data, it can
be relatively easy and inexpensive to generate new evaluation findings.
8. Ibid., p. 33
9 Barnes et al., EERE Guide, p. 25.
10 For installation programs, the categories of data used by the CESA National Clean Energy Database can be a good
starting point. See www.cleanenergystates.org/projects/cesa-national-clean-energy-database.
││
2.4 How to Choose Which Evaluations to Do
When deciding which evaluations to undertake, you should consider three factors:
How important and useful it will be to have the results of a particular evaluation.
How much it will cost (in both money and staff time) to carry out the evaluation.
How confident you can be that the findings of the evaluation will be accurate.
Unfortunately, it will frequently be the case that the evaluations you conclude are the most useful
will also be relatively expensive or may have considerable uncertainty associated with the results.
Therefore, except when you are in a situation where particular types of evaluation are mandated by
your agency’s board, regulators, or authorizing authority, it may make sense to develop an overall
annual evaluation plan that considers the agency’s overall budget for evaluation. For example, you
may have to choose between three easy, inexpensive but modest-value evaluations and one more
difficult, more expensive but potentially more valuable evaluation.
After considering the three factors above and your available budget, you may conclude that it does
not most sense to carry out the same evaluations that are most popular in other states or that first
come to mind or are recommended by evaluation contractors. You may instead end up selecting a
novel mix of evaluation projects.
2.5 Have Clear Evaluation Goals
Just as a program should have carefully developed and well-defined goals, an evaluation should
have clear goals. You will get more out of the evaluation if you know in detail what you hope to
achieve and you will increase the likelihood that the evaluator will design a research process that
exactly meets your needs.
As an example, it is not enough to decide that you want to do a process evaluation of the
effectiveness of a solar rebate program. There could be a variety of reasons why you want to know
how effective the program is and where its strengths and weaknesses reside, such as desiring to:
Identify modest process improvements that can be easily implemented in the near term.
Prepare for a major program redesign that has been mandated by your board.
Know how satisfied program participants (PV system purchasers) are with the program.
Know how satisfied solar companies are with the program.
Increase participants’ satisfaction, even if that increases the program’s cost.
Identify process efficiencies that would save money or reduce staff stress, whether or not
they increase participants’ satisfaction.
Understand the extent to which interconnection delays or installation quality issues, over
which you have limited control, cause participants to have a negative view of your agency.
Find out how your program compares to solar rebate programs in other states, and whether
there are procedures and processes being used elsewhere that you should adopt.
Learn whether there are significant differences in how the program has worked in different
parts of the state or with different groups of electricity customers.
││
Some evaluators may say that it is not desirable to get too specific at the beginning. They may
instead want to approach the assignment without preconceived notions and let the research data
be the sole determinant of the report’s findings and recommendations. But it is generally best to
point the evaluation towards your specific evaluation goals and needs. For example, it does not
make sense for the evaluator to provide detailed recommendations for how the program could be
totally revamped if funding will be ending soon and only small, incremental changes are possible.
2.6 How to Select Evaluators and Get the Most from Them
In some ways, selecting an evaluator is similar to selecting any other contractor. You need to
prepare a scope of services, solicit proposals, review proposals and qualifications, and discuss the
assignment with final candidates before making a decision. However, there are several special
considerations when choosing an evaluator.
2.6.1 Outside Contractors versus Internal Staff
Early on, you need to decide whether to recruit a specialized, outside evaluation firm for the
assignment or rely on staff members to carry out the evaluation. For many evaluation projects, it is
necessary to use an external evaluation expert because no staff member has the necessary expertise
or is perceived to be sufficiently impartial and objective. The more the assignment requires
specialized skills in sophisticated evaluation methodologies and the more public the results will be,
the more important it is to use an external evaluator.
Nevertheless, there are situations in which it makes sense to use a staff member for an evaluation
project. Not only is this likely to be a less expensive option but it can save time and effort to avoid
procuring a contractor and educating an outsider on the mission and activities of your agency. You
might consider using internal staff for evaluation if the particular evaluation task is narrowly
focused and designed for internal use rather than public dissemination. Examples include:
a short, several-question survey in which respondents’ responses are not likely to be affected
by knowing that the survey is being conducted by a staff member;
an informal market assessment focus group of clean energy business representatives, in
which your agency’s performance is not the subject of the focus group.
Another good use of internal staff is for analyzing data collected through the program’s monitoring
plan (see above) using a research methodology that is clear-cut and based on precedents either within
the agency or elsewhere. An example is an analysis of the size, geographic distribution, and
installation cost over time of solar projects supported by the agency.
Of course, if you are going to use a staff member for evaluation, that individual needs to possess
good general research skills and have experience with the specific evaluation methods required by
the project. Moreover, the person should not be directly involved in the program’s implementation
and should have the ability to bring a fresh, objective perspective to the task.
2.6.2 Choosing a Contractor
Before selecting an outside party to conduct an evaluation, you should think broadly about the nature
of the specific evaluation assignment, including the complexity of the research task, the content
knowledge the evaluator will need, and the audience for the final product. Decide up front which
││
of the following is most important for the evaluator to possess: significant experience with specific
complex research methods; knowledge of the clean energy industry or particular clean energy
technologies; or understanding of your state’s political and economic context. For example, with an
evaluation requiring use of a general equilibrium model of the state’s economy, it may make sense
to select the evaluator with the most proven success using that model rather than the evaluator
who has done the most work on clean energy. In another situation, the clean energy experience
might be more significant.
You should also consider how the particular evaluation project fits into your long -term evaluation
plans. Are you likely to do other, similar evaluations in the future? Will you want to establish an
ongoing relationship with the contractor, under the assumption that future projects will be easier
and more cost-effective if you work with an evaluator who already knows your agency and its
programs? Your selection of a contractor might be different depending upon whether you consider
the project a one-shot deal or the first of recurring assignments.
When interviewing firms that respond to your RFP, it is useful to explore their approach to
evaluation and their perspective. Although evaluators seek to be objective and fair, their
conclusions can be shaped by their views on evaluation, energy, the economy, and the role of
government. For example, you may want to ask:
Which research methods will they use and why? What do they think are the strengths and
weaknesses of those methods? Using those methods, how precise will the findings of the
evaluation be? What degree of uncertainty will there be in the results?
Leaving aside what you have asked for in your RFP, is there a different approach to the
evaluation task that they think would be better? You may discover something that causes
you to change course or find out that one of your RFP respondents is not completely
comfortable with what you are asking them to do.
Do the evaluators accept your program goals as valid and appropriate for an agency like
yours? You may discover that one of your respondents would come to the assignment with
philosophical concerns about certain programs or activities, including those that have been
mandated by legislation or established by your board.
You should also make sure that you understand (and accept) what the evaluator will expect from
you and your staff during the evaluation process. Many program managers have been caught off
guard because these expectations were not spelled out. An evaluator then later asked program
staff to provide much more information or participate in many more meetings than the program
manager anticipated.
2.6.3 Starting with a Shared Understanding
Although the process of interviewing respondents to your RFP can help ensure that you and your
evaluator start off with a shared general understanding of the assignment and your respective
roles, more extensive discussions should be held once the contractor is selected. You can thereby
make sure that the evaluator is aware of all the different in-house and external audiences that may
read the final report. You can help the evaluator understand the knowledge levels and needs of
those audiences. For example, an external evaluator is not likely to know ahead of time the extent
││
to which your board members or those on your authorizing body are familiar with the details of
your programs or the workings of the renewable energy marketplace.
Although the general parameters of the evaluation are likely to be clear from the RFP that was used
to select the contractor, there will still be considerable leeway about which specific questions should
be asked and answered, as well as how important the different questions will be. You should there-
fore discuss with the evaluator the list of questions. Although it may be necessary to defer to the
evaluator’s professional judgment, it is also important for the evaluator to understand the agency’s
point of view. As a starting point for thinking about possible questions, you may want to refer to
list of specific evaluation questions developed by DOE’s Office of Energy Efficiency and Renewable
Energy. They are reproduced in Appendix C below.
││
3. Recommendations for the Five Types of Evaluation
Although each state or agency needs to reach its own conclusions about which evaluations to carry
out, the research and discussions that underlie this report lead to some general thoughts on the five
different types of evaluation.
3.1 Needs and Market Assessment Studies
They can lead to better programs.
They can create baselines for future evaluations of program outcomes and
impacts.
Renewable energy agencies should do them more frequently.
It is obviously easier for an agency to design a successful program when it has an in-depth under-
standing of the audience it is trying to reach and the market it is trying to influence. Needs and
market assessment studies can be especially useful to programs that seek to build sustainable,
ongoing markets for renewable energy technologies. As program evaluators Mitchell Rosenberg
of KEMA and Lynn Hoefgen of NMR Group point out, “Programs designed to change the behavior
of market actors are most likely to succeed when their approach reflects market realities. Market
characterization studies that address issues of market size, customer segmentation, supply chain
structure and operations, incremental costs, patterns of customer behavior, and current levels of
product assessment provide the data required to develop effective program plans.”11
Renewable energy agencies will usually need to hire outside market assessment specialists and
industry experts to produce market assessment studies, but these reports can be less expensive than
some other types of evaluation, especially when the target technology and market are well-defined.
Moreover, even if it turns out that there is considerable uncertainty in some of the market assessment’s
conclusions (e.g., the size of the potential market, the most likely motivators of customer action),
the study is still likely to turn up useful information and identify issues that deserve attention in
program design. Market assessment studies can also help provide a baseline for later measuring
progress and program accomplishments.
3.2 Process Evaluations
They come in many shapes and sizes.
Renewable energy agencies should do them more frequently--especially small,
focused evaluation reports.
Customer satisfaction surveys are especially important.
Good program managers are always striving to improve their programs, and process evaluations can
help them do that. Not only can a process evaluation assess the program’s design, operations, and
11 Mitchell Rosenberg and Lynn Hoefgen, Market Effects and Market Transformation: Their Role in Energy
Efficiency Program Design and Evaluation (Oakland: California Institute for Energy and Environment, 2009), p. 6.
Available at http://uc-ciee.org/downloads/mrkt_effts_wp.pdf.
││
processes, but it can identify ways to improve a program’s management, increase its efficiency and
cost-effectiveness, strengthen its marketing, sharpen its audience targeting, and increase the satis-
faction of its customers and stakeholders. Even with a program that seems to be highly successful,
there is always room for improvement.
The key starting point for a successful process evaluation is a commitment on the part of program
managers and staff to use the results of the evaluation to improve the program. A process evalu-
ation can be strictly for internal staff use or it may be requested by a program’s governing authority
or be designed to share with wider audiences. It can start with a specific issue, such as a desire to
understand the reasons for low participation rates or a desire to reduce administrative costs. But a
process evaluation can also start from a more general interest in understanding and improving a
program. A process evaluation can be structured to focus on just one topic or can be a compre-
hensive assessment of the entire program.
A process evaluation can be conducted at any time, but it is obviously best to do it early enough in
a program’s lifecycle that there is still time to implement the report’s recommendations and make
changes to the program. A program can have multiple process evaluations over time.
Because process evaluations come in so many sizes and shapes, the budget for a study by an outside
evaluator can vary significantly—from perhaps $15,000 to $100,000—but this type of evaluation
tends to be less expensive than the other four types. And because process evaluations should lead
to near-term program improvements, it is well worth doing them frequently. An evaluation focused
on one or two specific questions can be especially desirable, because it is easy to implement and can
yield quick results.
It is even possible to use internal staff for a process evaluation that is narrowly focused and designed for
internal use. But it is important to consider the specific research skills needed —surveys, interviews,
focus groups, public opinion sampling techniques—and make sure that the evaluator, whether
internal or external, has them.
For a comprehensive process evaluation, it is best to use an external independent evaluator. Such
an evaluation may start by documenting current program practices as a baseline. According to the
California Evaluation Framework, the types of research activities that can be used in a compre-
hensive process evaluation include:
a. Reviews and tests of records, materials, tools, etc.,
b. Interviews and discussions with program management and staff, implementing
contractors, subcontractors, and field staff,
c. Interviews and discussions with policy makers, key stakeholders, and market actors,
d. Interviews, discussions, surveys and/or focus groups with participants and non -participants,
e. Collection and analysis of relevant data available from third-party sources (e.g. equipment
vendors),
f. Field observations, measurements, and examinations,
g. Other activities as needed to address researchable issues.12
12 TecMarket Works, California Evaluation Framework, p. 216.
││
Renewable energy agencies should think of themselves as service providers with “customers.” A
process evaluation can determine whether those customers are happy with a particular program
and with the agency. As evaluator Eric Oldsman of Nexus Associates points out, “All organizations
need to be concerned with the extent to which they are able to satisfy their customers. The degree
of satisfaction has a direct bearing on client loyalty, repeat business and the acquisition of new
customers.”13 Of course, this should by no means be the only measure of whether a program is
successful, but it is one important indicator. It is especially important to consider at a time when
all government operations are facing close scrutiny from the public and political leaders.
A customer satisfaction survey can be the centerpiece of a focused process evaluation or it can be
a component of a more comprehensive study.14 Such a survey is different from an interview with
customers to solicit their ideas for program improvement, although the two tasks can overlap or
be combined.
3.3 Outcome Evaluations
It is important to know whether a program is achieving its goals.
Depending upon the program and its intended outcomes, an outcome evaluation
can be relatively straight-forward or very complicated.
Consider up front whether the dissemination of research fi ndings can help key
stakeholders and will move a program toward its goals.
Any renewable energy program that an agency defines as major should have a plan for measuring
its outcomes. After all, if a program is aiming to achieve something meaningful, it is relevant to
know whether that milestone has been reached. Outcome evaluation should first be considered
when the program is being established. Are the goals and projected outcomes clear and specific
enough that there will be a way to assess—either quantitatively or qualitatively—whether they
have been achieved?
Some outcomes can be measured easily—simply by analyzing data that has already been collected
through a program’s monitoring activities (see section III above). But other outcomes are hard to
measure. For example, in the case of NYSERDA’s Clean Energy Infrastructure Program, whose pro-
gram logic model is included in Appendix B, there are both easy-to-measure outcomes (e.g., increase
in trained/certified installers) and much more difficult ones (e.g., end-users more accepting of clean
energy technology).
Although each program has its own wrinkles, we can divide programs into five groups for the
purpose of discussing how to do outcome evaluations of them.
13 Nexus Associates, Inc., Evaluation of Selected Initiatives Pursued under the Green Building and Infrastructure
Program (Belmont, Mass.: Nexus Associates, Inc., 2004), p. 23.
14 The Energy Trust of Oregon has developed a systematic way to get timely feedback from the homeowners,
businesses, and organizations that receive its grants. This approach could be adapted to other states. See Jane S.
Peters and Ryan E. Bliss, Final Report: Fast Feedback Program Rollout: Nonresidential and Residential Program
Portfolio (Portland: Research Into Action, 2010). Available at
http://energytrust.org/library/reports/101231_Fast_Feedback_Rollout.pdf.
││
3.3.1 Installation Programs
Programs that seek primarily to induce the installation of renewable energy technologies represent
the largest renewable energy program category. Depending upon the program’s goals, there can be
up to four different types of outcomes, which are described in a recent report from the US Environ -
mental Protection Agency on Assessing the Multiple Benefits of Clean Energy: A Resource for
States:15
Energy outcomes
Environmental outcomes
Electric system outcomes
Economic outcomes
3.3.1.1 Energy Outcomes.
An outcome evaluation of an installation program usually starts with assessing the energy outcomes.
Although program managers often set goals and outcomes for their renewable energy programs in
terms of the rated capacity of the systems (e.g., 25 megawatts of installed solar), it makes sense to
establish targets for the actual energy that will be produced. After all, energy production is the
reason why the systems are being installed so a program should know what it is hoping to achieve
in terms of megawatt hours per year.16 The evaluation can then determine whether the installations
are actually achieving that.
If the program is new and there is little experience with the particular technology in the state, it
may be difficult for program managers to establish precise production targets. But even approxi -
mate targets based on publicly available estimates of capacity factors can serve as a useful starting
point. The evaluation can then test the validity of those estimated targets.
For an evaluation to get from rated capacity to energy produced requires actual measurement of
system performance for at least a sample of the systems in your service area. The resulting data not
only helps program managers know whether they are achieving what they hope, but it can also
inform consumers’ decisions about whether to install renewable energy. In some cases, such as with
small wind systems in some parts of the country, energy production has turned out to be much less
than projected.
The task of monitoring production varies greatly with technology and system size. With large
utility-scale generators, owners already keep detailed production data. For photovoltaic systems,
the National Renewable Energy Laboratory’s PVWatts calculator17 can be used to estimate pro-
duction from systems in your area, although some sampling of actual production should be used
to test the accuracy of the estimates. Wisconsin’s Focus on Energy program has found Natural
15 US Environmental Protection Agency, Assessing the Multiple Benefits of Clean Energy: A Resource for States
(Washington: US EPA, 2010). Available at http://www.epa.gov/statelocalclimate/resources/benefits.html . This
report talks about four different types of benefits from installing clean energy, but outcomes can be placed into those
same four categories.
16 In the case of Wisconsin Focus On Energy, they go even further by setting targets not just for total megaw att
hours but also for peak megawatt hours, which are defined as 1 PM to 4 PM from July to September.
17 See www.nrel.gov/rredc/pvwatts/.
││
Resources Canada’s RETScreen18 to be a useful tool for estimating production from solar water
heating installations. Other small systems, such as biogas and small wind, can vary greatly
depending upon the site, manufacturer, installer, and operator, so estimates are difficult and
sampling techniques are tricky.19
Basic data on installations, costs, and energy production can be revealing and valuable when
analyzed for trends and key findings. California collects and disseminates hundreds of pages of
data evaluating the outcomes of the California Solar Initiative, including information by when the
systems were installed, type of system, customer categories, region, production by time of day and
season, and many other variables.20 This rich vein of information helps the California Public Utilities
Commission and California Energy Commission plan for the future, and it influences the business
strategies of the solar industry and electric utilities. Because other states do not have as many
installed systems as California, they may not have a large enough sample to produce the range of
findings that California does. Yet even with smaller numbers of systems and other technologies,
much can be learned by evaluating installation data and energy outcomes.
3.3.1.2 Environmental Outcomes.
Given that environmental improvement is usually a major reason for installing renewable energy
technologies, it often makes sense to quantify the emissions reductions associated with replacing
conventional generation with renewable energy.
The starting point for doing that is the energy production data gathered when evaluating the
program’s energy outcomes (see above). The next step is to determine the air pollution and green-
house gas emissions associated with that quantity of conventional generation, as well as the emis-
sions from any of the installed renewable energy technologies, such as biomass and geothermal.
There are a variety of approaches for doing that, some more precise and sophisticated than others.
At the simplest level, one can take the state’s overall generation mix and assume that the renew-
able energy generation displaced the various existing sources of electricity production proportion-
ately. That can yield results quite easily and can be sufficient for a modest evaluation report that
will not be disseminated outside the agency. But it does not account for the differences between
baseload and peak power, or that generating units that operate at the margin are the ones most
18 See www.retscreen.net/ang/home.php.
19 As part of the evaluation of Focus on Energy’s programs, a report described methods for calculating the
performance of various small-scale renewable technologies. This document can be useful to other states. See Bobbi
Tannenbaum et al., Focus on Energy Evaluation: Standard Calculation Recommendations for Renewable Energy
Systems (Madison, Tetra Tech, Inc., rev. ed. 2010); available at
www.focusonenergy.com/files/Document_Management_System/Evaluation/standardcalculationrecommendationsC
Y10_evaluationreport.pdf. For those who want to understand more about the advantages and reliability of dif ferent
methods for calculating the performance of distributed generation technologies, see a conference paper by
Tannenbaum’s colleagues at KEMA: Brian Dunn et al., ―Evaluating the Impacts of Customer -Sited Renewable
Energy Systems: Methods and Challenges,‖ paper presented at the 2009 International Energy Program Evaluation
Conference; available at www.iepec.org/2009PapersTOC/papers/024.pdf#page=1.
20 Itron, Inc. and KEMA, Inc., CPUC California Solar Initiative 2009 Impact Evaluation: Final Report (Itron, Inc.:
Davis, Cal.: 2010). Available at: www.cpuc.ca.gov/NR/rdonlyres/70B3F447-ADF5-48D3-8DF0-
5DCE0E9DD09E/0/2009_CSI_Impact_Report.pdf. An interesting collection of graphs is presented in a PowerPoint
slide collection by Glenn Harris, The CPUC’s CSI in Pictures: An Update through March 2010. It is available at
www.suncentricinc.com/downloads/SunCentric_CSI_Study_May_2010.pdf.
││
likely to be displaced by renewable energy. So it is better to use a methodology that tries to identify
and recognize which types of generators have been displaced.
Once an evaluation has decided to identify the types of generators that have been displaced, there
is another fork in the road, since either basic or more sophisticated approaches can be used for that
task. In most cases, the basic, less expensive approaches should provide sufficient precision and detail
for gaining a general understanding of the emissions reductions from renewable energy installations.
For example, by using a basic approach for several of your programs, you will get a useful rough
sense of how the programs compare in terms of their emissions impacts. You should therefore only
embark on a more complex and costly modeling study when there is a specific reason for doing so—
perhaps a regulatory or rule-making requirement.
The various methodologies for quantifying environmental outcomes are described in a helpful,
thorough, but sometimes hard-to-follow, chapter in EPA’s report on Assessing the Multiple Benefits
of Clean Energy: A Resource for States.21 The chapter describes the advantages and limitations of
each approach, as well as many specific methods for implementing those approaches. In addition,
it identifies and describes many relevant tools, databases, resources, and emissions inventories.
The EPA report also discusses how to go beyond quantifying emissions reductions to pin down the
air quality and health improvements that come from those emissions reductions. Although that will
rarely be the most important evaluation study for a clean energy agency to undertake, the EPA
report provides useful guidance on how to do it.
An extra complication of environmental outcomes evaluations is that it is much easier to quantify
the smokestack emissions from power plants, than the indirect emissions caused by building a
generating facility or obtaining and transporting fuel. Evaluation studies often ignore those indirect
emissions even though they are relevant to a complete environmental accounting of the impact of
renewable energy installations. Agencies can leave themselves vulnerable to criticism by ignoring
the emissions connected to such things as producing the steel in wind turbines. But the solution to
this problem will rarely be to conduct a precise assessment of all the indirect emissions associated
with particular facilities, since that would usually be quite costly and complicated. At a minimum, an
environmental outcomes evaluation should acknowledge this issue and note that the study looked
only at direct onsite emissions. It might also be good to look for and consider referring to any
previous studies that have attempted to quantify the indirect emissions from the use of various
electricity generating technologies in the state or region.
3.3.1.3 Electric System Outcomes.
Renewable energy installations can benefit the electricity system in ways that are often not
recognized or quantified, and that can lower the overall cost of electricity. For one thing, adding
renewable energy capacity can reduce the use of high-priced generators at the margin. For another
thing, distributed renewable energy systems can reduce several types of costs associated with the
local transmission and distribution of electricity.22
21 ―Assessing the Air Pollution, Greenhouse Gas, Air Quality, and Health Benefits of Clean Energy Initiatives,‖
chapter 4 in US EPA, Assessing the Multiple Benefits of Clean Energy, pp. 93-132.
22 US EPA, Assessing the Multiple Benefits of Clean Energy includes a good overview of the various benefits to the
electricity system and how to quantify them, but keep in mind that certain of the benefits relate more to energy
││
It can be difficult and costly to quantify these benefits with precision and may not be desirable to
try to do so unless you are undertaking a full cost-benefit evaluation of a program (see section on
cost-benefit evaluations below). However, it is worth identifying which types of electric system
benefits are likely to accrue from a particular renewable energy program and make sure that your
evaluators and key audiences are aware of those benefits. You can also gather information about
previous studies that have attempted to quantify those types of benefits. In that way, you can have
a rough sense of the likely order of magnitude of each benefit, while keeping in mind those
differences in location and timing can make a big difference.
Although it will generally not be an evaluation priority to commission a study solely to quantify
electricity system benefits, there are two circumstances in which it may make sense to do so:
1. When there are good reasons to believe that there are unusual and especially noteworthy
electricity system benefits associated with a program. For example, a forward capacity
market in New England creates some special economic benefits to installing renewable
energy generation in Connecticut.
2. When an agency believes it would be useful to undertake a generic analysis of one or more
electricity system benefits in their market. An example of such a study is the report that
Synapse Energy Economics undertook for the Commonwealth of Massachusetts on Impacts
of Distributed Generation on Wholesale Electric Prices and Air Emissions in Massachusetts.23
Additional generic studies by other states would allow comparisons between markets and
make it possible to provide quick estimates of the electricity system benefits of renewable
energy programs.
Of course, if clean energy agencies emphasize the unacknowledged electricity system benefits of
renewable energy, they should not ignore unacknowledged electricity system co sts of renewable
energy. For example, large-scale wind development can require additional spinning reserve or the
construction of additional transmission lines.
3.3.1.4 Economic Outcomes.
To understand a renewable energy installation program’s overall economic outcomes is the same as
looking at all its direct and indirect costs and benefits. That topic is discussed below in the section
on Cost-Benefit Evaluations.
3.3.2 Market Transformation Programs
Some renewable energy programs aim not only to increase the number of near-term installations
but to transform the market for a particular renewable energy product, such as photovoltaic
modules or highly efficient wood stoves. The goal is to create a market that will ultimately sustain
itself without continued support from the program. Such market transformation programs need to
efficiency than renewable energy. See chapter 4, ―Assessing the Electric System Benefits of C lean Energy,‖ pp. 51-
92.
23 Michael W. Drunsic et al., Impacts of Distributed Generation on Wholesale Electric Prices and Air Emissions in
Massachusetts (Cambridge: Synapse Energy Economics, 2008). Available at www.synapse-
energy.com/Downloads/SynapseReport.2008-03.MTC.Price-and-Emissions-Impacts-of-DG-in-MA.07-080.pdf.
││
be evaluated differently than installation programs, although the number of installations can be an
important indicator of whether the market is on track to being permanently changed.
It is essential for a market transformation program to have a clearly articulated theory of how the
market needs to be changed and how the program will contribute to that change. A detailed pro-
gram logic model is therefore likely to be essential. The specific changes identified in that model
can then be used as the key indicators to evaluate.
For example, an evaluation of a solar market transformation program might look to measure
whether there has been increased public awareness of the technology, more installations, more
certified vendors and installers, increased module availability, reduced prices, improved reliability
of the products installed, and more consumer protection measures in place.
To develop such a list of indicators, some market transformation programs identify the barriers to a
sustained market for the product. They then target those barriers through the program and
evaluate which of the barriers have been reduced over time.
However, markets are not always transformed simply by knocking down some of the specific
barriers to greater market penetration. The program therefore needs to have an understanding of
how the market works and what is truly necessary to change it permanently. To develop this can
require market assessment studies and/or an understanding of some of the general theories of
market transformation, such as the diffusion of innovation model. But, in the end, the key point
related to evaluation is that an outcomes evaluation of a market transformation program should be
based on an assessment of progress towards clearly defined indicators.24
3.3.3. Business Development Programs
States have implemented a range of programs to strengthen clean energy businesses and build
clean energy business clusters. The outcomes of such programs can be evaluated in a variety of
ways, depending upon the purpose and nature of the particular program.
3.3.3.1 Direct Jobs and Other Direct Measurements.
The simplest, and often most relevant, way to evaluate the outcomes of a business development
program is to compare the amount of money invested to the number of jobs directly created at the
companies that received that investment. This is an appropriate way of judging the success of a
business development program given that an increase in the number of jobs is generally one of its
primary goals. There are well-established methodologies for how economic development agencies
count direct jobs and job years.
Of course, the number of near-term direct jobs may not be a sufficient way to judge whether a
program is on track. For example, an agency may choose to invest in small, start-up companies,
knowing that it will be many years before those companies are large enough to employ significant
24 A useful report for program managers working on market transformation programs is Rosenberg and Hoefgen,
Market Effects and Market Transformation. Although there are differences between energy efficiency and
renewables programs, some of the report’s advice can be applied to designing and evaluation renewable energy
market transformation programs. And there is background information on topics such as models of market
transformation.
││
numbers of people. But in that case, well-chosen program goals and a detailed program logic model
can make those expectations clear well before the program is evaluated.
Other direct measurements of the success of a business development program can include how
much additional investment the state agency’s funding leverages at the time of an investment in a
company, the amount of additional non-state funding the company receives in the months and
years after the state agency invests, and the agency’s rate of return on its investment. Case studies
of investments in individual companies can also be useful.
3.3.3.2 Cluster Maps and Industry Censuses.
When the development of a particular business cluster (e.g., a local wind energy industry cluster) is
a goal of a program, it is worthwhile to map and assess the growth of that cluster over time. The
evaluation can identify which companies are in the cluster, what their financial resources an d sales
are, how many people they employ, and how the different companies relate to each other. Beyond
any evaluation purposes, this information can be valuable to program managers as they carry out
the program and can also be useful to the companies in the cluster.
More broadly, a state can produce a comprehensive census of its entire clean energy industry, as
Massachusetts did in its 2007 Massachusetts Clean Energy Industry Census.25 Information collected
through the census can be useful for determining whether specific business development programs
are contributing to the type of economic growth envisioned. But a census will not tell how much of
that growth was a direct result of the program, since general economic trends and private sector
developments likely play the biggest roles.
If completed before a program begins, an industry census can also be an important part of a market
assessment study. Changes can then be charted over time. Whenever it is done, a clean energy
industry census is likely to be of great interest to policymakers and the media.
3.3.3.3 Broader Outcomes of Business Development Programs.
Beyond the direct jobs and other direct outcomes at companies that receive state funding, the state’s
investments have broader impacts on the economy as the money invested and goods produced
ripple through the economy. For example, Connecticut Innovations has concluded that, for every
dollar it invested in companies in clean energy and other sectors, the state realized $1.97 in net
state revenue, the gross domestic product increased by $23.80, and personal income increased by
$14.30.26 But to produce such findings requires using the types of models and tools discussed below
in the section on Cost-Benefit Evaluations.
3.3.4 Research, R&D, and Demonstration Programs
25 Global Insight Inc., Massachusetts Clean Energy Industry Census (Westborough: Massachusetts Technology
Collaborative, 2007). Available at www.cleanenergycouncil.org/files/Clean-Energy-Census-Report-2007.pdf.
26 Peter V. Longo, ―Connecticut Innovations: A Presentation to Clean Energy States Alliance,‖ April 23, 2010.
Available at
www.cleanenergystates.org/Presentations/CESA_Presentations/4.23.10/Peter_Longo_CESA_Presentation%282%29
.pdf.
││
State energy funds carry out a wide range of different types of research, R&D, and technology
demonstration programs. Evaluation methods can vary widely depending upon the program. For
a report for DOE’s Office of Energy Efficiency and Renewable Energy, Rosalie Ruegg and Gretchen
Jordan examined the methods that various federal agencies use to evaluate research and they
found 14 different approaches that could be applied to energy research programs.27
For successful evaluation of the outcomes of research, R&D, and demonstration programs —and
indeed for successful design of such programs—it is important to have a clear understanding of
what the specific outcomes of the program are supposed to be. Those outcomes should be more
specific than just saying, for example, that the program seeks to advance research on new solar
technologies or to fund demonstrations of cutting-edge marine technologies. The key questions
are: why are such things receiving public support and what will be the specific results if the
activities are successful?
In the case of demonstration projects, the desired outcomes can range from generating certified
performance data, opening up early markets for a technology by making a product visible while it
is still in its prototype stage, convincing reluctant partners that a technology is viable, encouraging
private sector investment, and providing revenue for early-stage companies to help them pass
through the so-called valley of death.28 R&D programs can have a comparable array of possible
outcomes.
This is therefore an area in which a carefully crafted program logic model can be especially helpful.
NYSERDA has a wide-ranging research and development program and other states may consider
excerpting and modifying elements of its program theory and logic model for their own R&D
programs, which are likely to be more narrowly focused.29
Here are a few evaluation methods that can be used depending upon the nature of the program
and its goals:
Peer review and expert judging have long been mainstays in the research world. When
applied in a rigorous manner they can illuminate the quality of research and its relevance.
Counting and analyzing citations and other references to a publication can reveal the
dissemination of information and ideas. It is useful to understand how the research funded
by your agency ripples through society.
Network analysis can show the relationships among researchers.
Surveys and case studies can also be appropriate.
27 Rosalie Ruegg and Gretchen Jordan, Overview of Evaluation Methods for R&D Programs (Washington: US
Department of Energy Office of Energy Efficiency and Renewable Energy, 2007). Available at
www1.eere.energy.gov/ba/pba/pdfs/evaluation_methods_r_and_d.pdf.
28 The varied roles and potential impacts of demonstration projects are discussed in Chris Hendry et al., The
Uncertain Middle: Innovation Lessons for Low Carbon Energy Technology from Demonstration Projects and Trials
(London: Advanced Institute of Management Research, 2010). Available at
http://www.aimresearch.org/index.php?page=the-uncertain-middle-the-role-of-demonstration-projects-and-trials-in-
influencing-success.
29 GDS Associates, Sector Level Program Logic: SBC Funded Research and Development (R&D) Program
(Albany: NYSERDA, 2007). Available at
http://www.nyserda.org/energy_information/ContractorReports/GDS%20Associates/2007%20Reports/Final%20PL
M%20R%20and%20D%20Sector.pdf.
││
Some of the fruits of R&D projects may not become apparent for many years after your agency
supports them. It can therefore be useful to go back to long-finished projects to see how things
developed over time, so that your agency can capture and take credit for all of its accomplishments.
For example, have any of the technologies to which you provided early-stage support been later
commercialized in your state, and how big is their current market?
In addition, although it is important to focus most of the evaluation on a program’s specified
outcomes, research, R&D, and demonstration projects can also have unexpected spillover effects.
Evaluators should be encouraged to look for and document those results.
3.3.5 Education and Information Programs
Programs that focus on public education, the dissemination of information, or training can be
difficult to evaluate because they may not produce easily quantifiable results. It is especially impor-
tant that such programs have clearly defined objectives, audiences, information delivery mechanisms,
expected effects, and time frames. A diffuse, amorphous education effort will not only be hard to
evaluate, but it will be unlikely to have a significant impact. Program managers should make sure
that a good program theory is developed for such programs and should strive to identify measure-
able milestones and indicators wherever possible.30
Here are a few thoughts about evaluating education, information, and training programs:
1. Suitable evaluation methods can include surveys, interviews, and focus groups.
2. An initial market assessment study can provide a baseline for measuring the changes produced
by the program.
3. Because it can be difficult to measure the quantifiable outcomes of an education or information
program, process evaluations can be especially valuable. In that way, you can at least know
whether you are implementing the program efficiently and whether your target audience is
satisfied with the program.
4. To address the difficulty of measuring the results of these programs, clean energy agencies are
well served by sharing information and discussing best practices in these programs. In the pro-
gram development stage as well as in program evaluation, best practices can be identified and
you can ask evaluators to explain why they perceive them to be best practices. Dissemination to
other agencies of any conclusions about best practices is highly desirable.
5. Rather than attempt a comprehensive program evaluation of an education or informatio n
program, it sometimes makes sense to focus on a specific question that can be measured by
evaluators. For example, an agency could ask whether its brochures and website improve end-
users’ understanding of the advantages and disadvantages of installing a solar hot water
system.
30 Developing a program theory for an education or information program is discussed in TecMarket Works,
California Evaluation Framework, pp. 235-6. That discussion is part of a chapter on evaluation information and
programs that includes relevant information, even though some of it addresses the unique content needs and
bureaucratic requirements of utility-administered energy efficiency programs.
││
6. Sometimes the difficulty and potential cost of trying to evaluate the outcomes of an education
or information program reflect a deeper problem with program design. This can especially be
the case with small advertising and information efforts without a specific target audience, but
which instead claim to be trying to reach “the general public.” As the California Evaluation
Framework notes, “an evaluator may need to contact hundreds of potential readers or listeners
to find a few who were exposed to the message and who remember it…” That document warns
policymakers and program managers that “if the cost to identify and contact an individual
exposed to the program’s message is prohibitive,” it may mean that the program is having little
impact on the audience as a whole.31 On the other hand, it can be possible for an informational
campaign to increase some people’s awareness of your agency even though they cannot
remember being exposed to a particular message.
3.3.6 Another Approach: Comparisons between States
When program managers and their boards look to measure a program’s cost-effectiveness, they
often gravitate to commissioning a full-scale cost-benefit evaluation. An easier, less costly way to
measure a program’s cost-effectiveness is to compare its outcomes with those achieved by similar
programs in other states or jurisdictions. It is useful for program managers and others to know
whether they are able to achieve more—or less—with a given amount of money than other clean
energy programs are able to do. If similar programs in other states have already been evaluated,
it can be relatively inexpensive to make comparisons.
Some of the direct outcomes of installation and company support programs are especially well
suited to comparative analysis. An agency might compare how many megawatts of solar were
installed in different states for each $1 million of public funding or compare how many jobs
companies were created for each $1 million. As an example of this approach, one of the most
striking and significant findings from the evaluation of New York’s renewable portfolio standard
(RPS) program was that the program cost much less per megawatt installed than the RPS’s in other
states when measured by the price of renewable energy certificates.32
Of course, there can be many factors beyond an agency’s control that account for why a program’s
costs are higher or lower than those in other states. The comparative data can be a good starting
point for an analysis of the reasons for the differences.
3.4 Impact Evaluations
The more complicated the program theory and the more multi-faceted the
program’s route to achieving outcomes, the harder it is to determine exactly
which of the program’s outcomes would have occurred without the program.
It can be helpful to gather the results from evaluations of similar programs in
other states.
31 Ibid., p. 237.
32 Frank Stern et al., New York Renewable Portfolio Standard Market Conditions Assessment: Final Report (Denver:
Summit Blue Consulting, 2009), pp. 4-104 – 4-109. Available at
www.nyserda.org/Energy_Information/Market%20Conditions%20Final%20Report.pdf .
││
Choose experienced evaluators and make sure that they are using the most
appropriate research methods and are implementing them in the most
appropriate way.
Impact evaluations seek to take outcome evaluation one step further by determining which of the
outcomes can actually be attributed to the program. This is essential to fully assessing the value of a
program. If some of the outcomes would have taken place without the program, the program should
not take credit for them. Moreover, to the extent that some of the recipients of grants, rebates, or
loans were so-called “free riders” who would have acted without the state’s financial support,
program money was not used efficiently.
On the other hand, a program can have impacts that go beyond its original intended outcomes. For
example, a program to encourage businesses to install distributed systems for generating electricity
may induce them to use a combined-heat-and-power technology that also saves energy for heating.
Such desirable, but unintended, “spillover effects” deserve to be recognized.
Unfortunately, it is not always easy to accurately determine which of the outcomes of a program
can be attributed to that program. This is especially true for programs with complex goals and
multi-step routes to achieving those goals. Programs that transform a market or educate a broad
segment of the public fall into that category.
It is generally easiest to determine impacts for programs involving direct dissemination of program
funds to the actors that the program wants to influence (e.g., a solar rebate program or a green
schools planning grant program). Energy efficiency evaluators have been doing impact evaluations
of those types of programs (e.g., refrigerator rebate programs, grants for major energy-efficiency
improvements at manufacturing facilities) for decades and there has been extensive discussion at
their professional conferences and in written articles about the best methods for quantifying free
riders and spillover effects.
The most common and generally least expensive method is a survey of program participants. The
best surveys not only ask direct questions (e.g., how important was the state’s solar program in your
decision to purchase a solar system?) but also include indirect questions that help gauge the reliability
of the respondents’ direct response (e.g., what plans, if any did you have to install a solar system
before learning about the state’s program?; what were the main reasons that you decided to go
ahead with purchasing a solar system?). To further increase the reliability of the results, the survey
responses can be combined with other data sources, such as interviews with business and trade
association representatives.
But even when the evaluators are highly skilled and the survey is well constructed, peopl e’s answers
may not completely reflect the actual relationship between the program and the respondents’ actions.
For one thing, if the survey is being done long after respondents’ purchase or implementation
decisions, they may not remember their decision process accurately.
The imprecision associated with participant surveys tends to underestimate the impact of state
renewable energy programs. Because of participants’ enthusiasm for renewable energy and desire
to be perceived as environmentally responsible, they may tell the interviewer—and actually
││
believe—that they would have taken action without the state’s financial incentives, when that was
not the case. In addition, even if participants intended to purchase a renewable energy system with-
out financial support within a year or two after their actual purchase, intervening events could have
changed their plans. And they may not be aware of indirect ways in which the state’s program has
influenced them, such as by motivating a renewable energy installation company to run advertise-
ments that prompted them to become interested in purchasing a system or through educational
materials that prompted a neighbor to talk up the benefits of renewable energy .
A recent astute study of Wisconsin Focus on Energy’s biogas program showed the limitations of
surveys of program participants. When a survey-based impact evaluation indicated that most of
the participants in the biogas program reported that they would have installed a biogas digester
on their farm without the program, Focus on Energy asked the evaluator, KEMA, Inc., to carry out
a follow-up study to test the results. KEMA compared Wisconsin to two other similar agricultural
states, and then considered the extent to which higher market penetration of biogas digesters in
Wisconsin could be linked to Focus on Energy’s program. The evaluators also carried out qualitative
research, including interviews with various market players and experts to gain a more complete
understanding of the biogas digester market and Focus on Energy’s role in that market. Based
on those two approaches, KEMA concluded “that Focus on Energy has likely had impacts on the
Wisconsin biogas market not reflected in participant self-reports of program attribution.” But,
unfortunately, KEMA could not quantify those effects.33
In some cases, it may be possible to use statistical methods to come up with a quantitative estimate
of program impacts based on comparisons between program participants and non -participants or
between a program’s geographic focus areas and similar ones elsewhere where there is not a program.
However, those methods only work in certain situations, because data is not always available.
Another interesting approach, especially for market transformation programs, is “structured expert
judging”, in which a panel of marketing experts examines how the market for a product changed
over time and then forecast how that market would have changed in the absence of the
intervention of the renewable energy program. 34
You might take the following approach when considering doing an impact evaluation:
1. Consider how easy or difficult it will likely be to pinpoint the share of your program’s outcomes
that would still have occurred without the program, and how precise an answer you need. For
some programs, it may be too difficult or costly to determine an outcome-to-impact ratio with a
low margin of error. In those cases, it may be better to develop a very approximate estimate of
free riders and program attribution based on discussions with key stakeholders, staff, and
experts in the field, or other gross estimation techniques.
33 Bobbi Tannenbaum et al., Renewable Energy Program: Biogas Supply-Side Study (Madison: State of Wisconsin
Public Service Commission of Wisconsin, 2010), p. 1 -3. The report is available at
http://www.focusonenergy.com/files/Document_Management_System/Evaluation/biogassupplysidestudy_evaluatio
nreport.pdf.
34 For information on how structured expert judging has been used with energy efficiency programs, see Rosenberg
and Hoefgen, Market Effects and Market Transformation, pp. 90-96. Other methods for evaluating the impact of
market transformation programs are described on pp. 77-90 and 96-104.
││
2. Determine whether other states have produced impact evaluations of programs similar to yours
and find out what results they came up with for program impacts. Working with an evaluator,
consider whether there are reasons to think your program might have an outcome-to-impact
ratio outside the range of results from the other states. If your results would likely fall within
that range, consider whether you need a more precise answer and therefore need to
commission an impact evaluation report.
3. If you decide to do an impact evaluation, choose an evaluator with significant experience with
impact evaluations. Discuss the research methods they will use. If they are going to use a survey,
assess how sophisticated their survey methodology will be and whether they will supplement it
with other research and data.
4. Have the evaluator estimate the margin of error in the results and include a discussion of
uncertainties in the report.
5. For those programs for which there have been comparable impact reports in other states, if the
end result of your evaluation yields an outcome-to-impact ratio outside the range of results in
other states, have the evaluator provide a hypothesis or explanation for the difference. Make
sure that you are comfortable with that explanation before publishing the results of the study.
6. If an impact evaluation includes a survey of program participants, try to conduct it as close to
the time of the participant’s decision as possible to reduce the chance of faulty memories.
7. Have any survey do double duty as a mini-process evaluation. When the evaluator is talking
with your program’s clients for the purpose of determining which of their actions can be
attributed to your program, you can add in a few questions that will help determine their
satisfaction with your program and enable you to identify possible program improvements.
Even if additional questions are not asked, the participants’ answers to program attribution
questions will still likely provide interesting glimpses into their attitudes towards your program.
Those responses should be examined carefully for relevant impressionistic evidence.
3.5 Cost-Benefit Evaluations
Agencies should proceed cautiously before undertaking a major cost-benefit
study.
Assessments of benefits and costs usually involve predictions about the future,
which inherently introduce considerable uncertainty into the results.
Choose experienced evaluators and make sure you understand and agree with
their methodology and assumptions.
Make sure the study results are presented in ways that reveal rather than obscure
the assumptions and uncertainties.
Consider commentary by an economist as a low-cost alternative.
Just as an impact evaluation seeks to take an outcome evaluation one step further, a cost-benefit
assessment takes an impact evaluation one step further by weighing the benefits of achieving those
impacts against the costs. At first glance, this would appear to be an especially appealing type of
││
evaluation. After all, wouldn’t all program managers want to know if the economic benefits of
their programs outweigh the costs? Regulatory and authorizing bodies, such as agency boards
and legislative committees, often insist on a cost-benefit study so that they can judge whether
to continue a program or adjust its funding level.
Despite the obvious appeal of cost-benefit analysis, this can be the most problematic type of
evaluation, because the various research methods all have significant limitations. If one uses an
approach that looks only at easy-to-quantify, direct program spending (on the cost side) and the
direct savings that the recipients of that spending receive (on the benefit side), many important,
but harder-to-pinpoint economic impacts of the program are ignored. Those indirect impacts can
include the jobs created when a program causes purchases of renewable energy technologies, the
impact of new electricity generation on overall electricity prices, the economic benefits of reduced
pollution, and the economic impact of taking money from taxpayers or ratepayers to pay the taxes
or fees that fund the program.
To get at those more complicated economic effects requires the use of a quantitative economic
model, such as an input-output model, econometric model, or general equilibrium model.35 But
any quantitative model that tries to replicate real-life phenomena in something as complicated as
a state economy will inherently be flawed and will yield results with a considerable margin of error.
Nevertheless, quantitative analysis using models of the economy should not be rejected as useless,
since it remains the best way to understand what happens economically in the real world.
In the case of renewable energy programs, the research task is made more difficult, because
the evaluator needs to make projections about future trends as well as quantify past economic
activities. It is, of course, impossible to predict the future with total accuracy. Let’s take a wind
turbine installation program as an example. To calculate the benefits that the turbine owners will
derive over the life of the machines, one must estimate the value of the turbines’ output over a 25 -
year period. Yet it is notoriously difficult to predict future electricity prices and it may even be hard
to pinpoint the turbine’s future electricity generation, because the specific turbine model may not
have a long enough track record to predict performance degradation and maintenance needs
decades into the future.
The problems with forecasting the future do not end there. For example, how exactly will the
money spent by a renewable energy program ripple through the economy, creating a multiplier
effect as it gets spent by its initial recipients, and then re-spent? And what will be the value of
future avoided externalities when fossil fuel emissions are replaced by renewable generation? In
some cases, the introduction of significant quantities of renewable energy can suppress overall
electricity prices, because the increased production will reduce the use of high-priced generators
at the margin. But it is hard to pin down an exact price suppression number that can withstand
close scrutiny. As an illustration of this point, two careful analyses—one completed in 2008 and
one completed in 2009—of the projected price suppression impact of New York’s renewable
portfolio standard in 2010 came up with estimates that ranged from $33 for every megawatt-hour
of renewable energy generated to $107 per megawatt-hour. Although the second study offered
35 A few of the most frequently used models are described and analyzed in Appendix D.
││
plausible explanations for some of the differences between the two results, it is hard to have total
confidence in either result when there is such a large discrepancy.36
Because of all these complicated considerations, a full cost-benefit study can end up costing
$250,000, although a narrowly focused report that builds on previous analysis can cost as little as
a tenth of that. Given the potentially large price tag and the problems associated with cost-benefit
evaluations, how might it be best to proceed? Below is a suggested approach that will help you
understand the implications of what you receive from an evaluator, increase the usefulness of the
results, and help you avoid overselling those results.
a. Think carefully about why you want to undertake a cost-benefit evaluation and consider
whether the types of results you will likely receive will truly meet your needs. You can be con-
fident that a good cost-benefit study will identify the different ways in which a program has
an impact on the economy and will provide a general sense of the relative importance of those
different impacts. However, program managers generally want more than that from a cost-
benefit study. You should think carefully about what else you will receive that you will have
confidence in.
b. Choose an experienced evaluator who has conducted previous cost-benefit studies for satisfied
clients. This will increase the likelihood that you will get a sound report that can withstand
critical scrutiny. In your search for an experienced evaluator, you may discover that there is an
evaluation firm that already has a subscription to a relevant regional economic model so would
not have to pay for that as part of the cost of the evaluation. In addition, an evaluator may
already have done some related analysis of the state’s economy that could reduce the amount
of new work they have to do, and thereby hold down the cost of the evaluation.
c. Make sure you understand the research methods the evaluator will use. Ask the evaluator to
explain the advantages and limitations of those methods.
d. Have the evaluator specify and justify key assumptions that can shape report results, especially
those assumptions that involve predictions about the future, such as energy prices, equipment
costs, energy consumption, and equipment performance. Make sure that you believe that those
assumptions are defensible.
e. Ask the evaluator to assess more than one scenario. Even if you agree that a certain set of
assumptions about the future represents the most likely scenario, there remains considerable
possibility that future events will prove those assumptions wrong. You should therefore encour-
age the evaluator to consider and produce results for other plausible scenarios. This has not
conventionally been done with cost -benefit studies and could increase the budget for the
study by at least a modest amount, but it will make the results more meaningful and useful.
36 Frank Stern et al., New York Renewable Portfolio Standard: Market Conditions Assessment: Final Report
(Boulder, CO: Summit Blue Consulting, LLC, 2009), pp. 4-142 – 4-155. Available at
http://www.nyserda.org/Energy_Information/Market%20Conditions%20Final%20Report.pdf. In a recent paper
(Frank Felder, ―Examining Electricity Price Suppression Due to Renewable Resources and Other Grid Investments,‖
Electricity Journal (May 2011), pp. 34-46], Frank Felder explains why it is so difficult to accurately quantify price
suppression effects, although his article may overemphasize the potential impact of some relatively minor factors.
││
For example:
If the selected most likely scenario projects that electricity prices will increase by 3% a
year, how would the cost-benefit calculations be different if electricity prices rise by 5%
or do not rise at all?
If a wind program assumes that the price of new turbines will decline by 5% a year,
what difference would it make if the rate of decline is twice that or half that?
If a PV program assumes that inverters will last an average of 7 years, how would the
benefits be different if the inverters last 10 years or need to be replaced after only 5
years?
f. Cost-benefit studies usually require the evaluator to consider the opportunity cost of money
and to select a discount rate for that money. For example, in a sample of five state clean energy
cost-benefit studies conducted over the past six years, the discount rate used ranged from 3% to
10%. Make sure you understand the reasons for the evaluator’s choice of a discount rate. In the
final report, ask for an estimate to be included about how the results would be different if a
different discount rate had been chosen.
g. Ask the evaluator to look at previous comparable studies in both your state and other states.
To the extent that the results are different, have the evaluator explain and justify those
differences. For example:
If your study shows that every $100 million invested in wind energy will directly and
indirectly create 10,000 new jobs, but studies in five other states had results ranging
from 3,000 to 5,000 jobs, you should receive a convincing explanation for the
discrepancy.
h. Make sure you understand what exactly the study shows. That requires you to look carefully at
the relationship between cause and effect in order to understand why the study produced the
results it did. For example:
A 2009 study assessing whether to initiate a major new solar program in Connecticut
quantified the likely costs and benefits of six alternative program models. Overall, the
methodology seemed reasonable and the report showed that the societal benefits of all
six possible approaches would outweigh their costs, although some of the approaches
would be economically superior to others. The report recommended that the state go
forward with a comprehensive program incorporating several approaches.37 However,
a close reading of the findings shows that the vast majority of the economic benefits
Connecticut would receive from installing solar would come from avoiding costs
associated with the electricity that the solar would displace.38 In other words, anything
that displaced that electricity, including th e installation of other distributed generation
technologies and energy efficiency measures, would also have significant economic
37 KEMA, Sustainable Solar Strategy for Connecticut Prepared for the Long-Term Sustainable Solar Strategy
Workshop (Burlington, Mass.: KEMA, Inc., 2009), pp. 1 -3 – 1-6, and 2-12 – 2-15. Available at
www.ctcleanenergy.com/Portals/0/sustainable%20Solar%20Strategy%20FINAL%20Report%204 -8-09.pdf.
38 Ibid., appendix B.
││
benefits. Because no analysis was done comparing the costs and benefits of those
alternative technologies, some of which may have been more cost-effective than solar,
the report did not prove that a large new solar program was economically preferable.
i. As the last example implies, one way to increase the value of cost-benefit studies is to make
them comparative—for example, using them to compare the relative economic merits of imple-
menting two different parallel programs or the relative economic results from two of an agency’s
different programs. Even though there are inherent uncertainties in any cost-benefit study, one
can often trust the directional results comparing two studies using similar methodologies and
assumptions. For example:
In the Connecticut study described above, a solar residential rebate program was found
to have economic benefits 2.87 times greater than its costs, while the benefit-to-cost
ratio for a solar lease program would only be 1.92. Even though there could be signifi-
cant uncertainty around the exact numbers, there is no reason to disbelieve the finding
that a residential rebate would be more cost-effective.39
j. When presenting findings to governing authorities, regulators, and the public, avoid implying
that the results are more accurate and precise than they are. You can help your audience to see
the results as useful tools of greater understanding, rather than as definitive proclamations of
fact that they may be tempted to pick apart. For example:
Rather than proclaim that a report found the your agency’s geothermal program
provided $10,126,322 in economic benefits and created 412 jobs, you might suggest
that it uncovered about $10 million in benefits and about 400 jobs. If the evaluator ran
different scenarios, as recommended above in points 5 and 6, you can present the results
as a range that incorporates the different scenarios (e.g., $9-12 million in economic
benefits).
3.5.1 A Low-Cost Alternative to a Full Cost-Benefit Evaluation
If you do not have the budget for a full cost-benefit evaluation or are concerned that the inherent
uncertainties involved with assessing a particular project do not justify the time and resources of a
full study, you can consider a simple low-cost alternative—commentary from the perspective an
impartial professional economist.
In this approach, your agency would hire an external economist with significant experience doing
cost-benefit evaluations and ask that person to provide commentary rather than an evaluation. The
economist would look at relevant data collected by your agency as part of its monitoring program
and might ask you to gather some additional data.
The resulting report would not involve modeling but would instead discuss the types of things that
the economist knows are important to an economic modeling study, such as the amount of money
that gets spent within the state as a result of the program, the role of multiplier effects, and the
general impact of distributed generation on peak electricity prices. This can identify the ways in
39 Ibid., p. 1-5.
││
which the program is providing economic benefits to the state. Of course, this will not provide you
with a bottom line number showing that the program’s benefits outweigh its costs, but the
commentary can be suggestive and instructive.
Such a report can cost less than $10,000. The Vermont Clean Energy Development Fund recently
used this approach.40
40 Tom Kavet, ―Economic Overview of Clean Energy Development Fund Expenditures,‖ Memorandum to Vermont
Legislative Joint Fiscal Office, March 22, 2011. Available at
http://publicservice.vermont.gov/energy/ee_files/cedf/Memo%20-
%20Clean%20Energy%20Development%20Fund%20Summary.pdf.
││
4. Framing and Presenting Evaluations for Audiences outside Your Agency
In many cases, the evaluations produced for your agency will be seen by audiences outside the
agency, including the news media, political leaders in the state, clean energy business
representatives, and the general public. But agencies rarely focus on those audiences and instead
simply post the evaluations on their website where anyone can stumble across them without fully
understanding the context or being able to sort through the dense findings.
As part of an effective communications strategy, agencies should develop a proactive outreach plan
for each evaluation report when it commences. Here is a suggested approach for doing that:
1. When you are first conceptualizing an evaluation study, identify all the audiences that may see
it. Those should include audiences to whom you will intentionally disseminate the report, as
well as accidental audiences that may see it on your website or elsewhere. Of course, if the
report will solely be used internally within the agency, you do not need to worry about this.
2. Make sure the evaluators understand both the intended and accidental audiences. Brief them
on the various audiences’ level of knowledge about your agency and clean energy, as well as
their attitudes towards your agency and any concerns or pre-conceived notions that may
influence how they perceive the evaluation report. Discuss with the evaluators what this could
mean for how to frame and write the report.
3. Develop an outreach plan for each key audience. For example, consider whether you should
proactively disseminate the report to a certain audience, or whether it is sufficient to make the
report available on a website without directly reaching out to the audience about it. In
addition, decide whether the report should be accompanied by some contextual information,
such as a short description of the evaluated program, a brief explanation of the purpose of the
evaluation, or an overview of the agency’s overall evaluation strategy and evaluation activities.
4. Decide whether to ask the evaluators to produce collateral material that may be more appro-
priate for a particular audience than the full evaluation report. For example, the evaluators
could produce a slide presentation or a brief paper that addresses a specific concern of an
important audience.
5. Make sure that the report or any collateral materials, such as press releases, do not imply that
the results are more precise than they are. As noted in early sections of this paper, evaluation
reports leave themselves vulnerable to criticism when they exaggerate th e precision of the
findings.
6. Once you have seen the report but before it has been disseminated, anticipate how different
audiences will react to it and what their questions or concerns will be. Then develop responses
that you can use if necessary and appropriate.
││
7. Consider whether there is specific information in the report that could be useful to various
stakeholders but that they are not likely to uncover on their own. For example, solar energy
installers would not likely realize that an impacts report of your agency’s solar rebate program
could include survey responses that reveal the PV purchasers’ attitudes towards installers’
marketing efforts. You increase the value of evaluation studies by searching for and dissemin -
ating these sorts of unplanned but useful secondary findings and bits of information.
Beyond planning an outreach strategy for each individual evaluation report, it can be useful to
present key audiences with a general case for the value of evaluation. Evalu ation can be a signifi-
cant budget item and stakeholders may not understand why it is important or how it is used.
Moreover, by showing beneficial changes the agency has made as a result of particular evaluation
projects, you can demonstrate that the agenc y is spending public money wisely and is taking steps
to operate efficiently.
One good way to do that is to produce case studies of specific evaluation projects and their impacts.
The Office of Planning, Budget, and Analysis within DOE’s Office of Energy Efficiency and Renewable
Energy has done this successfully through a case study series. The attractive message of one of these
case studies is embodied in its title: “DOE Hydrogen Program Saved Nearly $30 Million by Investing
in Annual In-Progress Peer Reviews.”41
41 Office of Planning, Budget, and Analysis, ―DOE Hydrogen Program Saved Nearly $30 Million by Investing in
Annual In-Progress Peer Reviews,‖ Case Study Series—Demonstrating the Value of Program Evaluation (DOE
Office of Energy Efficiency and Renewable Energy, November 2009). Available at
www1.eere.energy.gov/ba/pba/pdfs/eere_finsavingsbrief-final.pdf.
││
APPENDICES
││
Appendix A: Developing a Program Theory
The material below, copied from The California Evaluation Framework,42 presents one reasonable
way to organize a project’s program theory and suggests how to get started on writing it.
Developing a Program Theory
The easiest way to develop a program theory is to start by systematically describing a program in
terms of resources, activities, outputs, short-term outcomes, and long-term outcomes:
Inputs (resources) are the elements required by an organization, program, or project to initiate
and/or sustain activities. Examples are money, collaborations, skills , and time.
Activities are the program activities that are used to produce the outputs that initiate the causal
logic within the logic model.
Market actors are those market actors targeted by the interventions or that play a role in the
causal logic of the program theory.
Outputs are the immediate results of the activity. Examples are the number of contacts made,
number of brochures printed, number of contractors recruited, and number of audits
completed.
Outcomes are the intermediate or once removed consequences resulting from program
activities and program outputs. There may be a sequence of outcomes. Outcomes m ay be
unintended or intended but they are not prompted by direct action on the part of the program.
Examples are changes in awareness, attitudes, and behaviors, participants referring non-
participants to the program, trade publications running articles about efficient equipment and
practices, dealers changing their stocking practices, etc.
Long-term outcomes (impacts) are the end-states to be realized. Impacts may take months or
years to accomplish and may be influenced indirectly by the intervener’s actio ns. Impacts are the
long-term goals of the program. Examples are kWh saved, gallons of water saved, tons of CO 2
reduced, efficient technologies and practices are the industry standard, T-12 fluorescents are
difficult to buy, etc.
One of the best ways to develop a program theory is to start with the long-term outcomes and
work backwards to resources. Essentially, the process is one of repeatedly asking the same question,
if “Z” is a long-term outcome…, what is required to produce “Z.” It is then a matter o f writing the
causal relation in the form of a statement: “Y” will cause “Z.” One then backs up and asks what will
cause Y and continues until one has described the required activities and resources.
One can then reverse the order and edit the statements until one has a sequence of causal
statements that describe how the program works….
42 TecMarket Works, The California Evaluation Framework: Prepared for the California Public Utilities
Commission and the Project Advisory Group (Oregon, Wisc.: TecMarket Works, revised edition 2006), p. 33-4.
Available at http://www.tecmarket.net/documents/California%20Evaluation%20Framework%20Jan%202006.pdf .
Note that the evaluation framework was developed for energy efficiency rather than renewable energy programs.
││
Appendix B: Sample Program Logic Model
NYSERDA produces and publishes thorough reports on the logic models for many of the agency’s
programs. These reports, many of which are available at the NYSERDA website at
www.nyserda.org/Energy_Information/evaluation.asp, can give other states a good understanding
of the issues to consider when developing a program logic model.
Figure 1 on next page shows the program logic diagram for the report on the Clean Energy
Infrastructure Program.43 Like the other NYSERDA reports, the one on that program includes much
more than just the diagram. It is 16 pages long and here is how the authors describe different
sections into which it is organized:44
1. Problem/Issues and Stakeholders (Context): Describes the problem(s) the program is attempting
to solve, or issues it will address and the regulatory and stakeholder environments (context)
within which the program is working.
2. Program Objectives: Describes, at a high level, the program’s ultimate purpose an d targets.
3. Program Resources: Identifies the dollar, manpower and partnership, etc. resources the program
is providing.
4. Program Activities: Describes the various research, product development, demonstration and
commercialization progress support activities and strategies being delivered through the
program.
5. Outputs: Describes the anticipated immediate results associated with program activities.
6. Outcomes: Describes what is expected to be achieved in the near, intermediate and longer term.
7. Assumptions: Describes assumptions about how program activities and outputs will lead to the
desired near, intermediate and longer-term outcomes.
8. Non-Program Influences: Describes factors outside the program that may drive or constrain the
achievement of outcomes.
43 GDS Associates, Inc., Program Logic Model Report: Clean Energy Infrastructure Program (Albany: NYSERDA,
2007), p. 13. Available at
http://www.nyserda.org/Energy_Information/ContractorReports/GDS%20Associates/2007%20Reports/Final%20PL
M%20Clean%20Energy.pdf.
44 Ibid., p. 1.
││
Figure 1. NYSERDA Clean Energy Infrastructure Program Logic Diagram
ActivitiesOutputsShort- and Intermediate-Term OutcomesLonger-Term OutcomesExternal Influences:Public and private capital for clean energy investments, competition from other states to recruit clean energy firms, changing energy costs, cost/performance of competing and complementary technologies, end users' willingness to adopt new technologies, perceptions about global warming, political/legislative/regulatory changesClean Energy Infrastructure Logic DiagramFINAL - September 12, 2007Project Development and SelectionMarket Barriers ResearchInputs:NYSERDA program funding, staff, NYSERDA R&D competenciesProject types prioritized, eligibility established for solicitationsResearch studies completed, stakeholder workshops conducted, barriers identifiedEducational materials (brochures, reports) published, workshops/seminars conducted, analytical tools available Strategies developed to address technical, economic, information and institutional barriersPotential end-users have increased awareness and knowledge of clean energy costs, benefits, operations; understand how to acquire it; confident in performancePONs issued, proposals selected for fundingTechnical, economic, information and institutional barriers overcome (including changes to regulations, standards)End-users more accepting of clean energy technology, increased demand for installationsIncrease in trained/certified clean energy installers and professionals, new training and certification programs developed, schools/programs accreditedTraining and certification available for clean-energy installers, code officials, inspectors, and marketers Strategic and flexible program portfolio developedTraining and CertificationInformation for Policy and Technology DevelopmentPre-Deployment AssistanceOutreach and Education to End-UsersIncentives for clean energy system installers available (passed through to end-users to reduce costs)Outreach and incentives to attract clean energy businesses to New York State, business partnering, planning and technical assistance availableGreater number/variety of clean energy system designers, manufacturers, distributors and service firms operating in State, start-ups assisted, innovative business strategies implemented, alliances formedInstallation IncentivesClean Energy Business Recruitment and AssistanceDiverse and profitable infrastructure of clean energy manufacturing and distribution firms in the State and associated jobs created, reduced system costs due to innovative business practicesReduced cost of installations and inspections, increased clean energy system performance and reliability, reduced operating costsMarket infrastructure is ready to supply and serve increased demand for clean energy
││
Appendix C: Possible Evaluation Questions
The following list of questions, copied from the EERE Guide for Managing General Program
Evaluation Studies,45 shows the wide range of questions that could be asked through a program
evaluation study. Of course, this list is not exhaustive and may not fully cover the issues raised by
your programs.46 It is presented here to help stimulate your thinking about evaluation goals and
questions.
General-to-Specific Evaluation Questions
Introduction
Once evaluation objectives are established, the research needs to be framed into general and
specific questions that can be the specific subjects of the research planning and evaluation effort.
General questions are derived from the evaluation objectives. Each general question implies certain
specific research questions that represent it. The specific questions are questions that are capable of
being answered through data collection and analysis. The following sets of general and specific
questions are grouped by type of evaluation:
Needs/market assessment
Process or implementation
Outcome
Impact
Cost-benefit.
These general and specific questions are offered as examples of the kinds of questions addressed by
the different types of general program evaluations.
A. Needs/Market Assessment Evaluation
General Question 1: What additional customers and markets could be served?
a. What are the currently underserved populations and market segments that could
benefit from the program?
b. Are there additional delivery channels that could be used to reach the target
populations?
General Question 2: What do customers need that is not currently being provided?
a. What gaps currently exist in the services available to target populations?
45 Harley Barnes et al., EERE Guide for Managing General Program Evaluation Studies: Getting the Information
You Need (Washington: US DOE, 2006), Appendix 4, pp. 4-1 – 4-6; available at
www1.eere.energy.gov/ba/pba/pdfs/evaluation_mgmt_guide_final_2006.pdf.
46 A different, even longer list of questions geared specifically to the impact of technology deployment programs is
available in John H. Reed at al., Impact Evaluation Framework for Technology Deployment Programs (Washington:
US DOE Energy Efficiency and Renewable Energy, 2007), pp. 5 -1 – 5-14; available at
www1.eere.energy.gov/ba/pba/pdfs/impact_framework_tech_deploy_2007_main.pdf.
││
b. What specific tools and services are needed by customers that are not provided by the
program?
General Question 3: What is the market baseline?
a. What are the key market segments?
b. Who are the key market actors and how do they interact?
c. What is the current extent of market penetration for the program’s targeted
technologies?
d. What is the nature and magnitude of current market barriers to the greater use of
technologies or practices promoted by the program?
B. Process or Implementation Evaluation
General Question 1: Is program design and organization adequate?
a. Are program goals too high? Too low?
b. What populations and market segments are being served, and through what delivery
channels?
c. Is it easy for customers to join or participate in the program?
d. What motivates customers to participate?
e. Are program delivery strategies consistent with customer motivations?
f. Do marketing materials emphasize benefits that have high value for customers?
g. Do the characteristics of the available tools and services allow for their easy adoption?
General Question 2: Is the program producing the outputs it was intended to produce?
a. What is the level of awareness of energy efficiency and renewable energy opportunities
in target populations?
b. Are customers participating at expected levels? Are some customer groups participating
more than others? Why?
c. Which tools and services are being used? By what groups? At what levels? Are some
tools and services under-utilized? Over-utilized? Why?
d. To what extent are customers satisfied with the program?
e. What are the key contextual and organizational factors that influence customers’ use of
the program’s tools and services? What is the magnitude of those influences?
General Question 3: Are resources reasonable relative to the objectives?
a. Are the resources assigned to the various program components adequate to achieve
desired objectives?
b. Is the program leveraging funds effectively? How could additional resources be
leveraged?
c. Are detailed program expenditure records maintained?
││
General Question 4: What are initiatives that are likely to enhance program results?
a. Are there barriers that reduce awareness of, or participation in, the program? How can
existing barriers be reduced or eliminated?
b. What could be done to increase the use of the program’s tools and services?
c. How can the program better reach and serve non-participants? Hard-to-reach
populations?
d. What are participant and non-participant recommendations for enhancements to
program process and content?
e. Are there areas for improvement in the program’s administrative functions (e.g.,
marketing, recruitment, record keeping)?
General Question 5: How can the program be modified to perform its activities at less cost and
still achieve goals?
a. Which delivery channels are working well (or not working) to achieve program
objectives at minimal cost? How do these delivery channels operate?
b. How can the effectiveness of the delivery channels be increased?
c. How can costs of administrative functions be reduced without adversely impacting
program services?
C. Outcome Evaluation
Quantify Savings
General Question 1: How much energy and money have been saved - directly and indirectly?
a. How much energy and money were saved by participants for the entire program?
b. How much energy and money were saved by participants for individual program
components/activities?
c. What are unaccounted-for “secondary” benefits (e.g., persistence, replication, delayed
implementation, spin-offs)?
d. What key contextual and organizational factors are related to the achievement of
energy and money savings? What is the strength of those relationships?
General Question 2: What are the non-energy benefits?
a. What were the nature and magnitude of non-energy benefits associated with the entire
program?
b. What were the nature and magnitude of non-energy benefits associated with individual
program components/activities?
c. What key contextual and organizational factors are related to the achievement of non-
energy benefits? What is the strength of those relationships?
General Question 3: What unexpected outcomes have occurred, if any?
││
a. What were the nature and magnitude of any program-related results that were not
intended?
b. What key contextual and organizational factors are related to the achievement of
unexpected results? What is the strength of those relationships?
Market Effects or Market Transformation
General Question 1: Are targeted markets showing signs of changing?
a. Are there market changes or effects associated with the entire program (e.g., changes in
business willingness or ability to produce, distribute, or service new technologies)?
b. What changes or effects are associated with individual program components/activities?
c. How has the behavior (e.g., purchase and management decision-making and practices)
of targeted actors changed over the life of the program?
d. What network effects have occurred?
e. What key contextual and organizational factors are related to the achievement of
market changes? What is the strength of those relationships?
General Question 2: What is progress toward desired long-term outcomes/exit strategy?
a. What are the nature and magnitude of any external replication effects that have
occurred?
b. What are the nature and magnitude of any network and spin-off effects (e.g., new
businesses and technologies)?
c. How effective has the program been in reducing market barriers?
General Question 3: Have sustainable markets been created?
a. Have market actors continued new practices and behaviors over time?
b. What are the effects of the program on the system specification and sales practices of
market actors who received program tools or services?
c. What key contextual and organizational factors are related to the achievement of
sustainable markets? What is the strength of those relationships?
D. Impact Evaluation
General Question 1: What are the verified quantified outcomes that are attributable to the
program?
a. What would have caused the observed outcomes if it were not the program? What
proportion of the measured outcomes were caused by the program?
b. What is the direct impact on customer awareness and knowledge that can be attributed
to the program?
c. What are the energy efficiency/renewable energy actions taken by program participants
compared to actions taken by non-participants?
d. What is the direct impact of the entire program on energy and money savings?
││
e. What is the direct impact of individual program components/activities on energy and
money savings?
f. What is the direct impact of the overall program on non-energy benefits?
g. What is the direct impact of individual program components/activities on non-energy
benefits?
h. What is the magnitude of replication, persistence, network, spillover, and other
observed effects that can be attributed to the program?
i. What unintended results were directly caused by the program?
j. What key contextual and organizational factors are responsible for the measured net
impacts? What is the strength of those causal relationships?
E. Cost-Benefit or Cost-Effectiveness Evaluation
General Question 1: What are the benefits and costs of the program’s past activities?
a. What are the retrospective benefits and costs associated with the program as a whole?
b. What are the retrospective benefits and costs associated with individual program
components/activities?
General Question 2: How do program benefits and costs comp are to each other?
a. Are the benefits from the program greater than program and customer costs?
b. What is the benefit-to-cost ratio (using one or more different perspectives, such as
“participant” or “societal”)?
c. Which delivery channels are working well to achieve program objectives less
expensively, and why?
││
Appendix D: Description of Models Used in Cost-Benefit Evaluations47
Evaluators usually use a model of the economy when undertaking a cost-benefit assessment. This
appendix discusses three models that are frequently used in studies of renewable energy’s impact
on the economy—IMPLAN, JEDI, and REMI. Other models have been developed for particular states,
such as ILREIM for Illinois, but they tend to be similar in approach to one of the three models
discussed below. All of them attempt to apply mainstream (neoclassical) economic theory using
mathematical equations and economic data.
IMPLAN
IMPLAN is an input-output model that was developed by the US Forest Service and is now marketed
as a commercial software package by an independent company, the Minnesota IMPLAN Group.
Input-output analysis is the most popular analytical approach for measuring economic impacts.48
Like other input-output models, IMPLAN divides the economy into a large number of industry and
commodity sectors, in this case the 528 standard industrial classifications. It then tracks the flow of
money—inputs and outputs—between them. A portion of the input (i.e., purchases) of one
industry will appear as an output (i.e., sales) of another industry. For example, steel is an input of
the wind industry, but is also an output of the steel industry. The input-output model measures how
a change in one part of the economy will ultimately affect other parts based on these purchasing
and selling relationships.
The main source data for of all such models in the United States is the Industry Economic Accounts,
especially the Annual and Benchmark Input-Output Accounts, produced by the Bureau of Economic
Analysis (BEA), which in turn depends on data from other federal agencies. BEA produces tables
that summarize at the national level which industries produce and consume which commodities
(including services). BEA updates its national accounts every five years.
These tables are then “regionalized”; using each region’s own industry mix and other information.
This regionalization would ideally be based on a survey that asked every individual business about
its suppliers and major clients. The responses would then be added up by industry. Because such a
survey is not practical, IMPLAN and the other input-output models use non-survey techniques that
rely on various regional data sources, including its industry mix.49
IMPLAN calculates local “multipliers,” which show how changes (jobs, earnings, or sales) in one
industry ripple through other industries in a regional economy. For example, a jobs multiplier of 2.1
for the photovoltaic industry in a state means that a change of 100 jobs in the PV industry would
lead to a total change of 210 jobs (2.1 x 100) in the whole regional economy
IMPLAN is relatively inexpensive and is easy to work with. But as a model of a regional economy it
has considerable limitations, especially when trying to measure changes extending far into the
47 This appendix draws on research by research assistant Benjamin Amankwata.
48 For an extended guide to input-output analysis, see M. Henry Robison, Input-Output Guidebook: A Practical
Guide for Regional Economic Analysis (Moscow, ID: Economic Modeling Specialists Inc., 2009). Available at
www.economicmodeling.com/wp-content/uploads/emsi-io-guide-1.pdf.
49 Ibid., p. 7.
││
future. Most importantly, input-output models are static and do not consider the inherent changes
over time in a dynamic economy. For example, IMPLAN assumes that there are no supply constraints
and that the relationship between industries is constant. In other words, the model would not have
projected the mid-2000s situation where increased demand for photovoltaic panels led to rapidly
rising silicon prices. The model also simplifies geographic differences by using national data that
assumes that products are made the same way in all regions, even though such factors as wage
rates, land costs, energy prices, transportation costs, and water scarcity could encourage a particular
industry to use different inputs in one part of the country than another. In addition, the model
looks at a state or region as a whole and places impacts either entirely inside or outside the region,
even though there could be significant variations. For example, the model does not recognize that
more of the money spent on home construction in a border community may slip out of state than in
a town in the center of the state.50
JEDI
Jobs and Economic Development Impact (JEDI) is based on IMPLAN and focuses specifically on
energy projects. There are JEDI models for wind, concentrating solar, PV, biofuels, coal, and natural
gas projects. These models were developed by the National Renewable Energy Laboratory (NREL) as
“user-friendly tools that estimate the economic impacts of constructing and operating power
generation and biofuel plants at the local and state levels.”51
In the case of a wind farm, for example, JEDI “estimates the number of in-state construction jobs”
and looks at three categories of economic impacts: (1) project development and onsite labor
impacts; (2) local revenue, turbine, and supply chain impacts, and (3) induced impacts, which are
changes in household spending as income increases because of the wind farm.52
The models operate in Excel and are easy to use. They include default values that NREL chose based
on interviews with project developers, state tax representatives, and others in the electric power
industry. But model users can replace the default values with project-specific data on such things as
construction costs, equipment costs, maintenance costs, and financing. They can also adjust the
proportion of project spending that is purchased locally in order to reflect project-specific realities.
JEDI has the same limitations as other input-output models, but it is also limited to looking at the
positive job and other economic impacts of projects. It cannot be used to analyze the negative
impacts on the economy of taking money from ratepayers or taxpayers to pay for the financial
incentives that make an energy project possible. In other words, JEDI can estimate the benefits of a
project, but not the costs. For this and other reasons, JEDI is most useful for understanding the types
of positive impacts a project or program will likely have and for making comparisons between
projects or programs.
50 Some of the limitations of IMPLAN are discussed in a presentation by Doleswar Bhandari and Jeffrey Mitchell,
―Regional Economic Impact Analysis: Simplifying Assumptions to Manage a Complex Task‖ presentation at the
University of New Mexico Bureau of Business and Economic Research Data Users Conference, November 6, 2008;
available at http://bber.unm.edu/presentations/Mitchell.pdf.
51 NREL’s JEDI website: www.nrel.gov/analysis/jedi; accessed April 24, 2011. The site includes information on the
JEDI methodology and sample publications that have used the models. The models are available for free
downloading.
52 About JEDI models: www.nrel.gov/analysis/jedi/about_jedi.html; accessed April 24, 2011.
││
REMI
The REMI model is maintained and distributed by a private organization, Regional Economic
Models, Inc. It incorporates aspects of four major modeling approaches: input-output, general
equilibrium, econometric, and new economic geography.
Each of these methodologies has distinct advantages as well as limitations when used alone REMI’s
integrated modeling approach makes it more robust than an input-output model like IMPLAN. For
example, the economic geography aspects of REMI incorporate the spatial dimension of the
economy. That allows the model to consider such things as the different transportation costs and
specialized labor costs for businesses in different locations. The general equilibrium properties of
the model incorporate the relationships between such variables as tax policies, regional prices, and
competitiveness.
The REMI model is customized to each region of the country using historical economic data going
back to 1990 provided by the US Bureau of Economic Analysis, the US Bureau of Labor Statistics, and
the Census Bureau. Users can input changes to consumption, employment, output, income,
productivity, fuel costs, production costs, wage rates, and other variables. The output variables
include employment, compensation, wage and salary disbursements, relative cost of production,
productivity, imports and exports, and output.
REMI consists of five blocks: (1) output and demand, (2) labor and capital demand, (3) population
and labor supply, (4) compensation, prices, and costs, and (5) market shares. The relationships
between the five blocks are captured in Figure 2.53
The main disadvantages of REMI compared to IMPLAN are that it is much more expensive and is
more difficult and complicated to use. It is important that the lead analyst be an experienced
evaluator with considerable experience using REMI.
53 www.remi.com; accessed June 7, 2011.
││
Figure 2. REMI Model Linkages
││
Appendix E: Reference Works
Barnes, Harley et al. EERE Guide for Managing General Program Evaluation Studies: Getting
the Information You Need. Washington: US DOE, 2006. This guide offers a clear step-by-step
approach for how to plan, design, and manage a program evaluation. Although the recommended
approach is sometimes overly bureaucratic and aimed at particular federal program management
needs, there is much useful information, some of which is reproduced in the appendix to this
report. Available at www1.eere.energy.gov/ba/pba/pdfs/evaluation_mgmt_guide_final_2006.pdf.
Horowitz, Paul. Glossary of Terms: Version 1.0. Lexington, Mass.: Northeast Energy Efficiency
Partnerships, 2009. This thorough glossary of evaluation-related terms and acronyms was produced
in conjunction with the Regional Evaluation, Measurement and Verification Forum of the Northeast
and Mid-Atlantic states. It covers terms commonly used by evaluators as well as terms related to
energy efficiency and demand-side management, many of which are also relevant to renewable
energy. Available at http://neep.org/uploads/EMV%20Forum/EMV%20Products/EMV-
F%20Glossary%20of%20Terms%20and%20Acronyms%20-%20Final%20March%202009.pdf.
Khawaja, M. Sam and Bob Baumgartner, “Uncertainty,” in Model Energy-Efficiency Program Impact
Evaluation Guide. Washington: National Action Plan for Energy Efficiency, 2007, pp. Appendix D-1 –
D-11. This relatively technical article provides an overview of the various factors that contribute to
uncertainty in evaluating energy efficiency programs and it explains how uncertainty can be
handled in an evaluation. Much of the discussion is relevant to renewable energy evaluation.
Available at www.epa.gov/cleanenergy/documents/suca/evaluation_guide.pdf .
Rosenberg, Mitchell and Lynn Hoefgen. Market Effects and Market Transformation: Their Role
in Energy Efficiency Program Design and Evaluation. Oakland: California Institute for Energy
and Environment, 2009. Although there are differences between energy efficiency and renewable
energy programs, some of this report’s advice can be applied to designing and evaluation
renewable energy market transformation programs. The sections on “Models of Market Effects and
Market Transformation” (2.3) and “Assessing Program Attribution” (6) are especially useful.
Available at http://uc-ciee.org/energyeff/documents/mrkt_effts_wp.pdf.
Schiller, Steven R. et al. Model Energy Efficiency Program Impact Evaluation Guide: A
Resource of the National Action Plan for Energy Efficiency. Washington: National Action Plan
for Energy Efficiency, 2007. Although much of the document focuses on matters specific to energy-
efficiency evaluation, some of it is relevant to renewable energy programs, including the
introductory section on basic principles of impact evaluation and the sections on calculating avoided
emissions and determining free ridership. Available at
www.epa.gov/cleanenergy/documents/suca/evaluation_guide.pdf.
Tannenbaum, Bobbi et al. Focus on Energy Evaluation: Standard Calculation
Recommendations for Renewable Energy Systems. Madison: Tetra Tech, Inc., revised edition
2010. This report for Wisconsin Focus on Energy describes methods for calculating the performance
of various small-scale renewable technologies. Those methods can be adapted to other states.
Available at
││
www.focusonenergy.com/files/Document_Management_System/Evaluation/standardcalculationreco
mmendationsCY10_evaluationreport.pdf.
Taylor-Powell, Ellen et al. Enhancing Program Performance with Logic Models: An Online
Course. Madison: University of Wisconsin—Extension, 2002. This online course provides beginners
with an accessible introduction to logic models and how to use them in program planning and
evaluation. It describes a variety of logic model formats. Available at www.uwex.edu/ces/lmcourse/#.
TecMarket Works et al. The California Evaluation Framework : Prepared for the California
Public Utilities Commission and the Project Advisory Group. Oregon, Wisc.: TecMarket Works,
revised edition 2006. This lengthy, comprehensive manual was produced to provide the California
Public Utilities Commission with a consistent methodology for evaluation the state’s energy
efficiency and resource acquisition programs. Although some of the manual applies only to the
specific needs of those programs, is aimed at evaluators rather than program managers, and
emphasizes a highly bureaucratized approach, it also includes much useful advice on a wide range
of different types of evaluations. It can serve as a valuable reference work for other states.
Available at
www.tecmarket.net/documents/California%20Evaluation%20Framework%20Jan%202006.pdf.
US Environmental Protection Agency. Assessing the Multiple Benefits of Clean Energy: A
Resource for States. Washington: US EPA, 2010. This report talks about four different types of
benefits from installing clean energy and describes ways to conduct evaluations of them. At times, it
is overly complicated and hard-to-follow but it includes much relevant information. Available at
www.epa.gov/statelocalclimate/resources/benefits.html.
W.K. Kellogg Foundation. Logic Model Development Guide. Battle Creek: W.K. Kellogg
Foundation, updated edition 2004. This detailed guide from one of the key organizations
promoting the use of logic models is useful to program managers who need to write logic models
and use them to identify appropriate questions for program evaluations. Available at
www.wkkf.org/knowledge-center/resources/2010/Logic-Model-Development-Guide.aspx.
││
Appendix F: Representative Evaluation Reports
The following renewable energy program evaluation reports could be useful for program managers
to examine. These are by no means the only high-quality reports that have been produced, but they
are good examples of their types. They include features and approaches that are applicable to other
states.
Report Title: Assessment of the New Jersey Renewable Energy Market
Author: Summit Blue Consulting, LLC
Renewable Energy Agency: New Jersey Board of Public Utilities
Date: 2008
Length: 148 pages
Purpose: Provide recommendations for New Jersey’s clean energy programs based on an
assessment of the renewable energy market in the state and the status of different renewable
energy technologies.
Description: This is a good example of a comprehensive market assessment study for a state clean
energy agency.
Where Available:
www.njcleanenergy.com/files/file/NJ%20RE%20Mkt%20Assmt%20Svc%20Rpt%20Vol%201%20FIN
AL%203-24-08.pdf
Report Title: Connecticut’s Economic Benefits from CCEF Small Solar and OSDG Programs
Author: Economic Development Research Group, Inc.
Renewable Energy Agency: Connecticut Clean Energy Fund
Date: 2009
Length: 56 pages
Purpose: Measure the economic impacts of investments in distributed generation. Evaluate the cost
effectiveness of continued investment in clean energy by the state of Connecticut.
Description: This well-organized report presents the results of an economic impact analysis and a
cost-benefit analysis. Using the REMI model, the report presents the change in the number of jobs,
income, and gross state output that it attributes to renewable energy spending. The various costs
and benefits analyzed are explained clearly. The report is strong in the comprehensiveness and
diversity of its analytical approach. Among its weaknesses, the report uses generic attribution rates
estimated by KEMA and an assumption that each project uses its estimated capacity and full
generation potential for the installation’s useful life. If these estimates, which are not based on
Connecticut-specific data or experience, turn out to be significantly off, the results of the study
might be flawed.
Where Available:
http://edrgroup.org/attachments/-01_CT%20Economic%20Benefits%20from%20CCEF.pdf
Report Title: CPUC California Solar Initiative 2009 Impact Evaluation: Final Report
Author: Itron, Inc. and KEMA, Inc.
Renewable Energy Agency: Southern California Edison and California Public Utilities Commission
Date: 2010
Length: 632 pages
Purpose: Assess the outcomes and impacts of the California Solar Initiative (CSI).
││
Description: The report examines CSI-funded solar systems that were operational in 2009. Detailed
data related to all of these systems is analyzed in myriad ways.
Where Available:
http://www.cpuc.ca.gov/NR/rdonlyres/70B3F447-ADF5-48D3-8DF0-
5DCE0E9DD09E/0/2009_CSI_Impact_Report.pdf
Report Title: The Economic and Environmental Impacts of Clean Energy Development in
Illinois
Author: Energy Resources Center (University of Illinois at Chicago)
Renewable Energy Agency: Illinois Department of Commerce and Economic Opportunity
Date: 2005
Length: 156 pages
Purpose: Measure the economic impacts of investing in energy efficiency, renewable energy, and
other clean energy power generation in Illinois.
Description: This report is a good example of a state assessment of a range of clean energy options
in order to help develop an overall state energy plan. It presents a thorough economic impact
analysis of potential clean energy investments using ILREIM, an Illinois-specific economic model. The
economic impacts are expressed in the net change in jobs, the net change in total economic output,
and the net change in income for state residents. This report provides a good example of how to
present critical facts and assumptions used in arriving at the final numbers. There is also a very
detailed explanation of the variations in project cost between projects (solar, wind etc.), over time
and also across uses (domestic, industrial etc). The report is presented in a clear and cogent fashion
that makes for easy interpretation and fact checking.
Where Available:
http://www.erc.uic.edu/PDF/Clean_Energy_Development.pdf
Report Title: Economic Overview of Clean Energy Development Fund Expenditures
Author: Kavet, Rockler & Associates, LLC
Renewable Energy Agency: Vermont Clean Energy Development Fund
Date: 2011
Length: 6 pages
Purpose: Describe and comment on the grants, tax credits, loans, and other expenditures made by
the Clean Energy Development Fund
Description: This brief report takes a low-cost, alternative approach to a full-fledged evaluation.
The author, part of a firm with significant experience doing cost-benefit evaluation and input-
output modeling in Vermont and elsewhere, worked with the fund to develop a database of all of
the Fund’s expenditures by category. The report presents those expenditures by type (e.g., grant,
loan), technology, and geographic location. It provides commentary on the ways in which the
expenditures benefit the state.
Where Available: http://publicservice.vermont.gov/energy/ee_files/cedf/Memo%20-
%20Clean%20Energy%20Development%20Fund%20Summary.pdf
Report Title: Evaluation of Energy Trust of Oregon’s Solar Programs: Solarize SE
Southeast Portland and Solar Energy Review
Author: Cadmus Group, Inc.
Renewable Energy Agency: Energy Trust of Oregon
││
Date: 2010
Length: 51 pages
Purpose: Gauge the effectiveness of two of Energy Trust of Oregon’s major solar programs and
determine participant satisfaction with those programs and with the Energy Trust.
Description: This is a well-done, straight-forward, process evaluation that provided the Energy
Trust with a lot of useful information and recommendations for improving the agency’s programs.
It relies heavily on interviews with the recipients of the Energy Trust’s funding and project support.
Where Available:
http://energytrust.org/library/reports/101101_SolarizeSE_Process_Eval.pdf
Report Title: Focus on Energy Evaluation, Renewable Energy Program: Biogas Supply-side
Study
Author: KEMA.
Renewable Energy Agency: Focus on Energy (Wisconsin)
Date: 2010
Length: 35 pages
Purpose: Assess the extent to which biogas activity in Wisconsin can be attributed to Focus on
Energy’s grant programs and outreach activities.
Description: This report is relevant to states interested in understanding the attribution issue and
alternative methodologies for assessing attribution. It uses two different approaches to understand
the role of Focus on Energy’s biogas activities on consumers’ decisions to install biogas systems in
agricultural settings. Careful detailed quantitative comparison of Wisconsin with other states takes
into consideration variables like farm size and suggests that market penetration is higher in
Wisconsin than elsewhere. Analysis of 19 in-depth interviews with a range of participants provides a
full picture of the Wisconsin biogas market in comparison to two comparable states. The report
explains why a previous evaluation that relied only on a survey of purchasers of biogas systems may
not have given enough credit to Focus on Energy’s education and outreach efforts. Despite all the
sound, interesting research that went into the report, the authors are not able to come up with
precise quantitative findings about attribution and their final conclusion is vague and general.
Where Available:
http://www.focusonenergy.com/files/Document_Management_System/Evaluation/biogassupplysidest
udy_evaluationreport.pdf
Report Title: Focus on Energy Evaluation, Renewables: Impact Evaluation January through
September CY09
Author: KEMA
Renewable Energy Agency: Focus on Energy (Wisconsin)
Date: 2009
Length: 109 pages
Purpose: To determine the percentage of program-tracked outcomes (demand and energy offset)
that is attributable to the Wisconsin Renewables Program.
Description: In this well-written and well-organized report, KEMA completed participant surveys
and engineering reviews to calculate overall realization rates, the percentage of program-tracked
outcomes that were caused by and attributable to the program. As part of the study, field
engineers examined a representative sample of installations to verify gross energy generation and
extrapolated to the remaining projects. Phone interviews were conducted with representatives of
││
95 installations. A noteworthy aspect of the report is a clear presentation of all key assumptions and
a sensitivity analysis of how the results would be impacted by changes or errors in these
assumptions. The participant survey, which is reproduced in the appendix, could be easily adapted
to other states. All the detailed responses of the survey respondents are also included in the
appendix, and they show the range of information a program can glean from a phone survey.
Where Available:
http://www.focusonenergy.com/files/Document_Management_System/Evaluation/renewablesimpact
evaluationjanthrusepcy09_evaluationreport.pdf
││
Acknowledgments
I want to thank the many people who helped me as I was researching and writing this report.
Mark Sinclair, the Executive Director of CESA, came up with the idea for this report and provided
me with advice along the way.
Several experienced evaluators made time for me to interview them and provided valuable insights:
Gretchen Jordan, Principal Member of Technical Staff at Sandia National Laboratories
Vivian Kan, Associate Economist at Regional Economics Models, Inc.
Thomas Kavet, President of Kavet, Rockler & Associates, LLC
Lisa Petraglia, Director of Economic Research for the Economic Development Research
Group, Inc.
Bobbi Tannenbaum, Principal at KEMA
Many representatives of CESA members provided me with information and advice. I especially want
to thank:
Lise Dondy, former President of the Connecticut Clean Energy Fund
Sandra Fromm, Supervisor in the Public Interest Research Division of the California Energy
Commission
Carole Nemore, Energy Analysis Project Manager at the New York State Energy Research &
Development Authority
Benjamin Amankwata served as a research assistant, analyzing previously conducted evaluations of
renewable energy programs.
Three people carefully read a draft of the report and provided me with valuable feedback and
useful suggestions:
Anne Margolis, Project Director for CESA
Elaine Prause, Renewable Energy Senior Program Manager at the Energy Trust of Oregon
Don Wichert, Director of Renewable Energy Services at the Wisconsin Energy Conservation
Corporation
Maria Blais Costello, Program and Grants Coordinator for CESA, handled final production.
Because I did not always listen to the advice I received from these people, they are not responsible
for any problems with the report, even though they very much help ed to improve it.
Warren Leon
Senior Advisor
Clean Energy States Alliance
June 2011