HomeMy WebLinkAboutCordova Eyak Biomass Case Study - Aug 2015 - REF Grant 2195399Cordova, Alaska
Cordova Wood Processing Plant
Quick Facts
Total Project Costs: $147,720
Equipment
Make/Model: Cord King 60
Output: 9 full cords/hour (128 cubic ft )
Diesel Fuel Offset
Estimated Annual: 88,700 gallons
Actual Annual: 4,500 gallons
Dec. 2011-Dec. 2014: 34,000 gallons
Fuel Savings
Estimated Annual: $427,321
Actual Annual: $12,000
Dec. 2011-Dec. 2014: $120,000
Estimated Payback: 10 years
Actual Payback: 3.7 years
Estimated Jobs Created: 3 seasonal
CASE STUDY
Project Overview
Th e native village of Eyak used grant funds for the
purchase, shipping, and set-up of a fi rewood proces-
sor in Cordova. Eyak identifi ed a specifi c system that
met their needs, a Cord King Model 60. Th e district
heating program focuses on reducing heating costs to
community members by using the Cord King 60 to
process their fi rewood. Th ey are now able to use local-
ly harvested biomass for heating rather than diesel oil.
Objectives
Th e main objective of this project was to meet the
heating needs of the Native Village of Eyak. Cordova
is only accessible by air or water so the cost of living
is about 25% higher than the U.S. average. Using this
fi rewood processing system allows residents to re-
duce high heating costs by minimizing their reliance
on diesel fuel. It also allows them to use a local and
renewable resource.
Reasons This Product Was Chosen
Th e Cord King Model 60 has a production rate of
up to nine full cords per hour, a cycle time of 3.5-4
seconds, a splitter system, and it’s hydraulic reservoir
capacity is 140 gallons. It’s effi ciency is higher than
other fi rewood processors of its kind and it can more
than meets the heating needs of Eyak.
Economic Feasibility
Th e system became operational in December of 2011,
and since then it has produced 4,080 MMBtu of
thermal energy and displaced 34,000 gallons of diesel
fuel, saving Eyak $120,000 in energy costs. Th e project
has a calculated benefi t/cost ratio of 20.31 and a 20
year projected life span, meaning that the benefi ts will
continue to outweigh the costs by 20.31 over the next
20 years.
Cord King Model 60, Photo courtesy of AEA.
Allocation of Funding
Th e Renewable Energy Fund contributed $136,760.
Funds went to the purchase, shipping, and set-up of
the Cord King 60. Local funds contributed $10,960
went toward administration, labor, and supplies.
Fuel and Storage
Wood cords are cut from existing dead or dry decked
trees and the Cord King 60 processes it into usable
fi rewood for community members. Th e wood supplies
a portion of the community’s winter heating needs and
reduces the cost of expensive heating oil. Cordova’s
annual heating fuel usage is equivalent to about 1,460
cords/year. Although this seems like a lot of wood, it
costs about one fi ft h of the price that they would pay
for diesel heating fuel, and the source is renewable.
Learning Experiences/Challenges
1. One of the most important aspects in the devel-
opment of any biomass project is the fuel supply.
Where is the wood coming from? Who is harvesting
the wood? What is the cost of the wood? Th e decked
wood that Eyak planned to process with the Cord King
proved to be rotten on the inside, and it has been a
challenge to identify other sources. Eyak is currently
working with the U.S. Forest Service to allow selected
portions of state land near Saddlebag Glacier to be
harvested for biomass fuel. Th is would help increase
available forest light, encourage mature forests to grow
in the area, and provide fuel for Cordova residents.
2. Eyak is also investigating a moose browse enhance-
ment project that would cut alder and spruce trees to
make room for primary willow trees. Th is would give
moose their preferred grazing food and provide resi-
dents with additional fuel as well.
Community Benefi ts
1. Th is project provided several local employment
opportunities in Cordova. When it was time to cut log
decks, Eyak was able to employ 3 full time seasonal
workers at $20-25/hour. Th is helped the community
become more invested in the project and provided an
income for several families.
2. With the purchase of the Cord King 60, Eyak was
able to provide fi rewood at cost to residents in need.
Th is was an exceptional deal, as the cost was less than
half of what residents would normally pay for fi re-
wood. In addition to that, Eyak was able to pay for
a dump truck that provided a much easier and cost
eff ective way to transport fi rewood to diff erent elders
who weren’t able to acquire fi rewood on their own.
Th e community benefi ts of this project have and will
continue to span generations.
Project Contact Information
Parties Involved:
John Whissel, Native Village of Eyak
Email: John.Whissel@eyak-nsn.gov
Case Study Author:
Zoe Tressel, AEA
Email: ztressel@aidea.org
Phone: 907-771-3000
Aerial view of Cordova, Photo courtesy of city-data.com.
Cordova, Alaska
Cordova wood stacks, Photo courtesy of AEA.