HomeMy WebLinkAboutPPC - Kongiganak Wind Farm Construction - room unit brochure 2006Save up to 70%
on your home
heating costs with a
Steffes Room Heater
Many people are taking advantage of low cost
electricity rates from their local power company
known as off-peak rates and saving hundreds,
even thousands of dollars on their home heating
bills. If you are looking for great comfort and relief
. from high propane, fuel oil or natural gas costs,
- now's the time for a Steffes Room Heater.
Getthe"Off-PeakAdvantage!"
Electricity is more expensive during the day — when we use a lot of
it. Dishwashers, washers and dryers, water heaters, computers...
it's a long list. Power companies charge lower rates at times when
less electricity is used. These lower rates are called "off-peak rates."
1.howitWorks
* The Steffes Room Heater stores low cost, off-peak electricity as heat
in its specially designed, ceramic bricks. The amount of heat stored is
regulated automatically based on the heating needs of your home and
outdoor temperatures.
The heater's built-in room thermostat and fan deliver the stored heat
into your home when needed to provide comfortable, even temperatures
throughout the house. It's quiet, easy to use, and can satisfy your desired
comfort 24 hours a day.
savemoney!
With a Steffes Room Heater, many homeowners are cutting their annual
heating bills by up to 70%, saving hundreds and even thousands of dollars.
TEPEES
� Heating Systems
701-483-5400
E-Mail: offpeak@steffes.com
Web: www.steffes.com
1. Heat Storage Bricks
2. Insulation
3. Heating Element
4. Temperature Control and Display Panel
5. Warm Discharge Air
6. Brick Core Temperature Sensor
7. Fan
C UL US
LISTED
MODEL Charging Inputs (kW) Approximate Dimensions (Inches)
Available (See Note 1) Installed Weight (lbs)
Length Height Depth
2102 (See Note 2)
2103
2.4, 3.0, 3.6
267
376
478
1 585
692
30
37
44
51
58
24.5
24.5
24.5
24.5
24.5
10.5
10.5
10.5
10.5
10.5
3.6,4.5,5.4
4.8, 6.0, 7.2
2104
2105
2106
6.0, 7.5, 9.0
7.2, 9.0,10.8
NOTE 1: kW input must be specified at time of order.The appropriate model and kW input for
your application will depend on heat loss of the area intended to be heated and the number of
power company off-peak hours available. Contact your local power company, a contractor or
Steffes Corporation for assistance in selecting an appropriately sized system.
NOTE 2: Model 2102 also available in a 1.32kW input with a 120V plug-in cord.
NOTE 3: A clearance of 12" is recommended on the MINIMUM CLEARANCE REQUIREMEN
right side of heater to ensure accurate room Top 4"
temperature sensing and for servicing purposes. If less I Front 15"
than 12"is available, an optional remote room I Sides (SeeNote3) 2"
temperature sensor is available
For More Information Contact:
Manufacturer reserves the right to discontinue or change at any time, specifications or designs, without notice or incurring obligations.