Loading...
HomeMy WebLinkAbout18021 Solomon Gulch Hydroelectric FacilityAlaska Energy Authority Renewable Energy Fund Program Round 18 7/7/2025 Contact Alaska Energy Authority Conner Erickson Variables Social Cost of Carbon Projection Social Cost of Carbon Rate of Increase Discount Rate Sheet Name Instructions 999-Calc Diesels ON Diesels OFF Assumptions Diesel Fuel Prices Railbelt Price Worksheet Natural Gas Prices Carbon Pricing Biomass Units cterickson@akenergyauthority.org Units (all $ are $2025) % per Year Annual Sheet Description Details the function of each cell in the model and appropriate inputs Provides an area to record all underlying calculations for figures used in the model Model for calculating the benefit-cost ratio of a project which does not result in diesel generators being turned off Model for calculating the benefit-cost ratio of a project which does result in diesel generators being turned off Lists assumptions used by AEA in calculating project economics Lists diesel generation fuel price projections for all fuel communities Lists fuel price projections and calculations for the Railbelt regions Lists natural gas price projections Lists carbon price projections and methodology Provides biomass reference material and an area to record information and figures specific to the biomass project Mid 0.03 0.03 PLEASE READ Home Hid rows including social cost of carbon assumptions Instructions PLEASE READ Updated field names to be consistent with "Economic Model" Updated instructions to be consistent with updates to "Economic Model" Highlighted where to include any potential reduction in recovered heat from an existing project due to the proposed REF project ('Displaced Heat') 999-Calc O&M $/hr assumptions for diesels Method $/kWh for O&M for diesels--added requirement for kWh of diesel generation. Uses division to calculate $/kWh for O&M Diesels ON Hid tab Economic Model Combined Diesels ON and Diesels OFF models into one model. Updated Nearest Fuel Community (non-railbelt only) lookup Update calculation for "Renewable Generation O&M". It is now an average of the sum of O&M and scheduled repairs for Heat & Electricity Reporting for natural gas in Mcf and not MMBtu (this is how contracts are written). Updated years to start at 2020 Updated rows 45 & 46 including equations Fixed NPV calculation in column BO (should be current year + PV of future) Added Renewable Other costs (Property tax, insurance) Added Renewable Heat Other costs (Property tax, insurance) Added field for "Diesels OFF time" Updated Diesels Off calculation to include number of hours diesels are turned off Updated naming for "Base Case" to include "Displaced" Assumptions O&M table hydro (reservoir) & run of river Rb (based on Bradley 2019) hydro rural biomass Solar PV Heat recovery Added notes to O&M estimates Wind project cost $/kW (based on ACEP 2016) Wind capacity factors Updated "NOTES" Diesel Fuel Prices Added new communities Updated fuel prices Start at 2020 Removed carbon price Real prices held constant after 2045 Railbelt Price Worksheet Updated heat rate for South of AK range Updated Coal forecast using 2019 AEO Updated Fuel use for North of AK range using 2018 GVEA reported values Removed unused row Start at 2020 Removed carbon price Real prices held constant after 2045 Natural Gas Prices Updated gas prices and explanation Real prices held constant after 2045 Carbon Conversion factors Changed name from Carbon Pricing Hid rows for carbon pricing Renewable Energy Fund Economic Benefit-Cost Analysis Model IMPORTANT: PLEASE READ INSTRUCTIONS PRIOR TO COMPLETING THE ECONOMIC MODEL. PLEASE CONTACT AEA WITH ANY QUESTIONS. Values are to be entered in the cells with blue background only. Cells which are not shaded SHOULD NOT be edited. IF THESE CELLS MUST BE CHANGED, CHANGE FONT COLOR TO BLUE AND NOTE WITH A "Entered Value" LABEL. INPUT: Manually enter the community where the project is located or that would be served by the project. It may be different than "Nearest Fuel Community". This cell is not linked to any other cells INPUT: Select from drop-down menu to select the community where the project is located or the nearest community with similar energy characteristics. This entry is linked to the look up table of the community fuel price. If the community is located on the Railbelt, then this cell is not used. INPUT: The region determines the fuel type the project will offset for electrical generation projects, fuel oil for rural region, natural gas utility power generation and space heating for Railbelt South of the Alaska Range, and fuel oil or coal for Railbelt North of the Alaska Range. Selecting the region automatically set the title and units of the project analysis worksheet cells so should be done before entering other project data. INPUT: Select from drop-down menu. INPUT: Enter appropriate information; this cell is not linked to any other cells. INPUT: Enter appropriate information; this cell is not linked to any other cells. INPUT: Enter appropriate information; this cell is not linked to any other cells. CALCULATION: Displays the NPV value of the benefits/savings provided by the project over its life. CALCULATION: Displays the total NPV value of the costs of the project over its life. CALCULATION: Displays the Benefit-Cost ratio CALCULATION: Displays the NPV value of the net benefit of the project over its life. CALCULATIONS: Displays summary performance measures of the project given the parameters provided. CALCULATION: Displays the total capital costs of the project. INPUT: Enter the year the project commences operation. INPUT: Use the applicant's project life information for the "Applicant B/C" model. For the "AEA B/C" model, use AEA's baseline assumption found in the "Assumptions" worksheet. INPUT: Enter only the renewable energy production that offsets base electric production. Generation in excess of the electric load (e.g. for heating) should not be entered into this cell. INPUT: Enter the amount of space heat produced by the proposed project in terms of displaced gallons of heating fuel or mmBtu of natural gas. If a project will decrease the amount of recovered heat from an existing heat recovery system, include the reduced displaced heat here. Input: Renewable O&M (Electric) is input here and is referenced by row 88. Input: Renewable O&M (Heat) is input here and is referenced by row 88. INPUT: If the project will operate in "Diesels OFF" mode, put in the expected hours the engines will remain off per year INPUT: Enter the installed capacity of the proposed electric system; this cell is not linked to any other cells. CALCULATION: Calculates the capacity factor INPUT: Enter the capacity of the propose heating system in Btu per hour; this cell is not linked to any other cells CALCULATION: Calculates the capacity factor INPUT: If appropriate, enter the estimated additional public benefit of the project beyond fuel displacement to be included in the B/C ratio calculations. Please enter value in row 62. Before using this feature, please read the accompanying notes provided as a word document in the comment section. Please show detailed source and/or assumptions in the 'Calc' worksheet. INPUT: Select size of base system engines from dropdown list INPUT: Manually enter current kWh/gallon INPUT: Enter the current total diesel generation for the community in cell C47 of "Economic Model" INPUT: Enter capital costs of the project in the year where they're expected to be incurred. CALCULATION: Calculated net benefits of the project from electricity CALCULATION: Calculated net benefits of the project from heat INPUT: If appropriate, enter the estimated additional public benefit of the project beyond fuel displacement to be included in the B/C ratio calculations. Before using this feature, please read the accompanying word document included in the comments section. Show detailed sources and/or assumptions in the 'Calc' worksheet. CALCULATION: Calculated total net benefits of the project. INPUT: Enter a value if the technology's output is expected to increase or decrease over time. For instance, a solar PV project will experience ~0.5% decrease in output per year or a hydro project may fulfill a greater load in the future. INPUT: Enter a value if one exists in the application. Note that standard repair and maintenance is included in the O&M estimate REFERENCE: By default, references cell D34 INPUT: Enter a value if one exists in the application. INPUT: Enter a value if one exists in the application, please see worksheet 'Biomass Units' for reference. Please show your all your calculations in the 'Calc' sheet. INPUT: Enter applicant provided value if one exists, provide documentation for other values in the notes section. CALCULATION: Calculated Fuel cost based on quantity and unit cost CALCULATION: Sum of all annual renewable energy costs CALCULATION: Cell changes title and units based on region, e.g. Railbelt South of the Range produces avoided costs in $/kWh INPUT: Enter applicant provided value if one exists, provide documentation for other values in the notes section. DO NOT USE IF DIESELS DO NOT TURN OFF CALCULATION: These cells will autocalculate by default. If there is good information with which to provide a more nuanced analysis please refer to assumption about O&M in both the assumptions tab and use the format provided in the Calc tab. Please document all alternate values in notes section. CALCULATION: These cells will autocalculate by default based on displaced generation and generation efficiency. CALCULATION: These cells will autocalculate by default. CALCULATION: INPUT: Enter applicant provided value if one exists, provide documentation for other values in the notes section. INPUT: Enter applicant provided value if one exists, provide documentation for other values in the notes section. INPUT: Enter applicant provided value if one exists, provide documentation for other values in the notes section. INPUT: Enter a value if one exists in the application, please see worksheet 'Biomass Units' for reference. This will also be used for heat pumps, pumping loads for heat recovery, etc. Please show your all your calculations in the 'Calc' sheet. INPUT: Enter applicant provided value if one exists, provide documentation for other values in the notes section. CALCULATION: CALCULATION: Enter applicant provided value if one exists, provide documentation for other values in the notes section. Enter applicant provided value if one exists, provide documentation for other values in the notes section. Project Description Community Nearest Fuel Community Region RE Technology Project ID Applicant Name Project Title Results NPV Benefits NPV Capital Costs B/C Ratio NPV Net Benefit Performance Displaced Electricity Displaced Electricity Displaced Petroleum Fuel Displaced Petroleum Fuel Displaced Natural Gas Displaced Natural Gas Avoided CO2 Avoided CO2 Proposed System Capital Costs Project Start Project Life Displaced Electric Displaced Heat Renewable Generation O&M (Electric) Renewable Generation O&M (Heat) Diesels OFF time Electric Capacity Electric Capacity Factor Heating Capacity Heating Capacity Factor Total Other Public Benefit Base System - Non-Railbelt Only Diesel Generator O&M Applicant's Diesel Generator Efficiency Diesel Generation Efficiency Annual Cost and Savings Entered Value Entered Value Electric Proposed Entered Value Entered Value Entered Value Entered Value Base Entered Value Heating Proposed Entered Value Entered Value Entered Value Entered Value Entered Value Base Entered Value Entered Value Unit kWh per year total lifetime kWh gallons per year total lifetime gallons MCF per year total lifetime MCF tonnes per year total lifetime tonnes Unit $ year years kWh per year gallons displaced per year $ per year $ per year Hours per year kW % Btu/hr % 2025$ (Total over the life of the project) Size of impacted engines (select from list) 361-600kW kWh per gallon Total current annual generation Project Capital Cost Electric Cost Savings Heating Cost Savings Other Public Benefits Total Cost Savings Net Benefit Renewable Generation Renewable scheduled replacement(s) Renewable O&M Renewable Electric Other costs Renewable Fuel Use Quantity (Biomass) Renewable Fuel Cost Total Renewable Fuel Cost Proposed Generation Cost Displaced Fossil Fuel Generation Avoided Generation Cost Displaced Scheduled component replacement(s) Displaced O&M Displaced Fuel Use Displaced Fuel Cost Base Generation Displaced Cost Renewable Heat Scheduled Repairs Renewable Heat O&M Renewable Heat Other costs Renewable Fuel Use Quantity Renewable Fuel Cost Total Renewable Fuel Cost Proposed Heat Cost Displaced Fuel Use Displaced Fuel Cost Displaced Scheduled Repairs Displaced O&M Displaced Annual Fuel Cost Base Heating Displaced Cost Value Value $/hr 9.95 13 kWh/gallon 13 Units $ per year $ per year $ per year $ per year $ per year $ per year Units kWh per year $ per year $ per year green tons $ per unit $ per year $ per year kWh per year $/gallon or $/kWh $ per year $ per year gallons per year $ per year $ per year Units $ per year $ per year $ per year green tons/kWh/etc. $ per unit $ per year $ per year gallons per year $ per gallon $ per year $ per year $ per year $ per year 4 2022 2022 2022 Comments: (Please assign comment ID and hyperlink next to applicable column/row) ID 1 5 2023 2023 2023 Description PUBLIC BENEFITS. Please read attached document 6 2024 2024 2024 7 2025 2025 2025 8 2026 2026 2026 9 2027 2027 2027 10 2028 2028 2028 11 2029 2029 2029 12 2030 2030 2030 13 2031 2031 2031 14 2032 2032 2032 15 2033 2033 2033 16 2034 2034 2034 17 2035 2035 2035 18 2036 2036 2036 19 2037 2037 2037 20 2038 2038 2038 21 2039 2039 2039 22 2040 2040 2040 23 2041 2041 2041 24 2042 2042 2042 25 2043 2043 2043 26 2044 2044 2044 27 2045 2045 2045 28 2046 2046 2046 29 2047 2047 2047 30 2048 2048 2048 31 2049 2049 2049 32 2050 2050 2050 33 2051 2051 2051 34 2052 2052 2052 35 2053 2053 2053 36 2054 2054 2054 37 2055 2055 2055 38 2056 2056 2056 39 2057 2057 2057 40 2058 2058 2058 41 2059 2059 2059 42 2060 2060 2060 43 2061 2061 2061 44 2062 2062 2062 45 2063 2063 2063 46 2064 2064 2064 47 2065 2065 2065 48 2066 2066 2066 49 2067 2067 2067 50 2068 2068 2068 51 2069 2069 2069 52 2070 2070 2070 53 2071 2071 2071 54 2072 2072 2072 55 2073 2073 2073 56 2074 2074 2074 57 2075 2075 2075 58 2076 2076 2076 59 2077 2077 2077 60 2078 2078 2078 61 2079 2079 2079 62 2080 2080 2080 63 2081 2081 2081 64 2082 2082 2082 65 2083 2083 2083 PV PV PV CODE TO UNLOCK ECONOMIC MODEL WORKSHEET REFRound18 Please use this worksheet to show all your calculations. Base Case O&M - For Diesels OFF ONLY Average kWh/year generated by diesel Average load Genset Power Class 60-150kW 151-360kW 361-600kW 601-1,300kW If you can estimate run-hours saved on diesel engines please calculate an annual cost and resulting cost per kWh based on your project's specifications. If you do not have this information use the cost/kWh provided above. # hours diesels OFF per year 0 $/hour 7.0097 9.3463 9.9463 15.1551 Estimated renewable generation kWh/year $/kWh test Calculated base case $/kWh # of Cylinders 4 6 6 or 8 8 to 16 Sample Gensets JD4045 JD6068/6081/6090, DD Series 60, Cat C9 Cat 3456/3408/C18/C27, MTU 1600, Cummins QSX15 Cat 3508/3512/3516 839208 950928 8402296 10192432 1790136 4201148 Spending timeline Feasibility and Conceptual Design Final Design and Permitting Construction Total This effort, 2026-2027 Spread over two years, 2028-2029 2026 895068 895068 2027 895068 895068 2028 4201148 4201148 2029 4201148 4201148 Renewable Energy Fund Economic Benefit-Cost Analysis Model - Diesels ON Project Description Community Nearest Fuel Community (non-railbelt only) Region RE Technology Project ID Applicant Name Project Title Results NPV Benefits NPV Capital Costs B/C Ratio NPV Net Benefit Performance Displaced Electricity Displaced Electricity Displaced Petroleum Fuel Displaced Petroleum Fuel Displaced Natural Gas Displaced Natural Gas Avoided CO2 Avoided CO2 Proposed System Capital Costs Project Start Project Life Displaced Electric Displaced Heat Renewable Generation O&M Electric Capacity Electric Capacity Factor Heating Capacity Heating Capacity Factor Total Other Public Benefit Base System - Non-Railbelt Only Diesel Generator O&M Applicant's Diesel Generator Efficiency Diesel Generation Efficiency Annual Cost Savings Entered Value Entered Value Electric Proposed - Marginal cost only Entered Value Entered Value Entered Value Entered Value Entered Value Base - Fuel and capacity cost only Heating Proposed Entered Value Entered Value Entered Value Entered Value Entered Value Base Entered Value Entered Value Entered Value Railbelt South of Alaska Range Hydro (Run of River) 0 0 0 Unit kWh per year total lifetime kWh gallons per year total lifetime gallons MCFper year total lifetime MCF tonnes per year total lifetime tonnes Unit $ year years kWh per year MCF displaced per year $ per year kW % Btu/hr % 2023$ (Total over the life of the project) Size of impacted engines (select from list) 60-150kW kWh per gallon Total current annual diesel generation Project Capital Cost Electric Cost Savings Heating Cost Savings Other Public Benefits Total Cost Savings Net Benefit Renewable Generation Scheduled replacement(s) Renewable O&M - Annual marginal change Renewable Other costs Renewable Fuel Use Quantity (Biomass) Renewable Fuel Cost Total Renewable Fuel Cost Proposed Generation Cost Fossil Fuel Generation Avoided Generation Cost Fuel Use Base Generation Avoided Cost Renewable Heat Renewable Heat Scheduled Repairs Renewable Heat O&M Renewable Heat Other costs Renewable Fuel Use Quantity (Biomass) Renewable Fuel Cost Total Renewable Fuel Cost Proposed Heat Cost Fuel Use Fuel Cost Scheduled Repairs O&M Annual Fuel Cost Base Heating Cost Value 0 0 0 0 0 0 0 0 Value 0 0 $/kWh kWh/gallon Units $ per year $ per year $ per year $ per year $ per year $ per year Units kWh per year $ per year $ per year green tons $ per unit $ per year $ per year kWh per year $ per kWh MCF per year $ per year Units MCF per year $ per year $ per year $ per year green tons $ per unit $ per year $ per year MCF per year $ per MCF $ per year $ per year $ per year $ per year 4 2023 0 0 0 0 0 0 2023 0 0 0 0 0 0 0 0 0 0.0783 0 0 2023 0 0 0 0 0 0 Comments: (Please assign comment ID and hyperlink next to applicable column/row) ID 1 5 2024 0 0 0 0 0 0 2024 0 0 0 0 0 0 0 0 0 0.0745 0 0 2024 0 0 0 0 0 0 Description PUBLIC BENEFITS. Before using this new feature, please read the accompanying notes in the Instructions tab 6 2025 0 0 0 0 0 2025 0 0 0 0 0 0 0 0 0 0.0712 0 0 2025 0 0 0 0 0 0 7 2026 0 0 0 0 0 2026 0 0 0 0 0 0 0 0 0 0.0742 0 0 2026 0 0 0 0 0 0 8 2027 0 0 0 0 0 2027 0 0 0 0 0 0 0 0 0 0.0787 0 0 2027 0 0 0 0 0 0 9 2028 0 0 0 0 0 0 2028 0 0 0 0 0 0 0 0 0 0.0838 0 0 2028 0 0 0 0 0 0 10 2029 0 0 0 0 0 0 2029 0 0 0 0 0 0 0 0 0 0.0878 0 0 2029 0 0 0 0 0 0 11 2030 0 0 0 0 0 0 2030 0 0 0 0 0 0 0 0 0 0.1007 0 0 2030 0 0 0 0 0 0 12 2031 0 0 0 0 0 0 2031 0 0 0 0 0 0 0 0 0 0.1116 0 0 2031 0 0 0 0 0 0 13 2032 0 0 0 0 0 0 2032 0 0 0 0 0 0 0 0 0 0.118 0 0 2032 0 0 0 0 0 0 14 2033 0 0 0 0 0 0 2033 0 0 0 0 0 0 0 0 0 0.1204 0 0 2033 0 0 0 0 0 0 15 2034 0 0 0 0 0 0 2034 0 0 0 0 0 0 0 0 0 0.1204 0 0 2034 0 0 0 0 0 0 16 2035 0 0 0 0 0 0 2035 0 0 0 0 0 0 0 0 0 0.1189 0 0 2035 0 0 0 0 0 0 17 2036 0 0 0 0 0 0 2036 0 0 0 0 0 0 0 0 0 0.1172 0 0 2036 0 0 0 0 0 0 18 2037 0 0 0 0 0 0 2037 0 0 0 0 0 0 0 0 0 0.1155 0 0 2037 0 0 0 0 0 0 19 2038 0 0 0 0 0 0 2038 0 0 0 0 0 0 0 0 0 0.1161 0 0 2038 0 0 0 0 0 0 20 2039 0 0 0 0 0 0 2039 0 0 0 0 0 0 0 0 0 0.1182 0 0 2039 0 0 0 0 0 0 21 2040 0 0 0 0 0 0 2040 0 0 0 0 0 0 0 0 0 0.1203 0 0 2040 0 0 0 0 0 0 22 2041 0 0 0 0 0 0 2041 0 0 0 0 0 0 0 0 0 0.1239 0 0 2041 0 0 0 0 0 0 23 2042 0 0 0 0 0 0 2042 0 0 0 0 0 0 0 0 0 0.1262 0 0 2042 0 0 0 0 0 0 24 2043 0 0 0 0 0 0 2043 0 0 0 0 0 0 0 0 0 0.1278 0 0 2043 0 0 0 0 0 0 25 2044 0 0 0 0 0 0 2044 0 0 0 0 0 0 0 0 0 0.1301 0 0 2044 0 0 0 0 0 0 26 2045 0 0 0 0 0 0 2045 0 0 0 0 0 0 0 0 0 0.1314 0 0 2045 0 0 0 0 0 0 27 2046 0 0 0 0 0 0 2046 0 0 0 0 0 0 0 0 0 0.1313 0 0 2046 0 0 0 0 0 0 28 2047 0 0 0 0 0 0 2047 0 0 0 0 0 0 0 0 0 0.1307 0 0 2047 0 0 0 0 0 0 29 2048 0 0 0 0 0 0 2048 0 0 0 0 0 0 0 0 0 0.1307 0 0 2048 0 0 0 0 0 0 30 2049 0 0 0 0 0 0 2049 0 0 0 0 0 0 0 0 0 0.1313 0 0 2049 0 0 0 0 0 0 31 2050 0 0 0 0 0 0 2050 0 0 0 0 0 0 0 0 0 0.1313 0 0 2050 0 0 0 0 0 0 32 2051 0 0 0 0 0 0 2051 0 0 0 0 0 0 0 0 0 0.1313 0 0 2051 0 0 0 0 0 0 33 2052 0 0 0 0 0 0 2052 0 0 0 0 0 0 0 0 0 0.1313 0 0 2052 0 0 0 0 0 0 34 2053 0 0 0 0 0 0 2053 0 0 0 0 0 0 0 0 0 0.1313 0 0 2053 0 0 0 0 0 0 35 2054 0 0 0 0 0 0 2054 0 0 0 0 0 0 0 0 0 0.1313 0 0 2054 0 0 0 0 0 0 36 2055 0 0 0 0 0 0 2055 0 0 0 0 0 0 0 0 0 0.1313 0 0 2055 0 0 0 0 0 0 37 2056 0 0 0 0 0 0 2056 0 0 0 0 0 0 0 0 0 0.1313 0 0 2056 0 0 0 0 0 0 38 2057 0 0 0 0 0 0 2057 0 0 0 0 0 0 0 0 0 0.1313 0 0 2057 0 0 0 0 0 0 39 2058 0 0 0 0 0 0 2058 0 0 0 0 0 0 0 0 0 0.1313 0 0 2058 0 0 0 0 0 0 40 2059 0 0 0 0 0 0 2059 0 0 0 0 0 0 0 0 0 0.1313 0 0 2059 0 0 0 0 0 0 41 2060 0 0 0 0 0 0 2060 0 0 0 0 0 0 0 0 0 0.1313 0 0 2060 0 0 0 0 0 0 42 2061 0 0 0 0 0 0 2061 0 0 0 0 0 0 0 0 0 0.1313 0 0 2061 0 0 0 0 0 0 43 2062 0 0 0 0 0 0 2062 0 0 0 0 0 0 0 0 0 0.1313 0 0 2062 0 0 0 0 0 0 44 2063 0 0 0 0 0 0 2063 0 0 0 0 0 0 0 0 0 0.1313 0 0 2063 0 0 0 0 0 0 45 2064 0 0 0 0 0 0 2064 0 0 0 0 0 0 0 0 0 0.1313 0 0 2064 0 0 0 0 0 0 46 2065 0 0 0 0 0 0 2065 0 0 0 0 0 0 0 0 0 0.1313 0 0 2065 0 0 0 0 0 0 47 2066 0 0 0 0 0 0 2066 0 0 0 0 0 0 0 0 0 0.1313 0 0 2066 0 0 0 0 0 0 48 2067 0 0 0 0 0 0 2067 0 0 0 0 0 0 0 0 0 0.1313 0 0 2067 0 0 0 0 0 0 49 2068 0 0 0 0 0 0 2068 0 0 0 0 0 0 0 0 0 0.1313 0 0 2068 0 0 0 0 0 0 50 2069 0 0 0 0 0 0 2069 0 0 0 0 0 0 0 0 0 0.1313 0 0 2069 0 0 0 0 0 0 51 2070 0 0 0 0 0 0 2070 0 0 0 0 0 0 0 0 0 0.1313 0 0 2070 0 0 0 0 0 0 52 2071 0 0 0 0 0 0 2071 0 0 0 0 0 0 0 0 0 0.1313 0 0 2071 0 0 0 0 0 0 53 2072 0 0 0 0 0 0 2072 0 0 0 0 0 0 0 0 0 0.1313 0 0 2072 0 0 0 0 0 0 54 2073 0 0 0 0 0 0 2073 0 0 0 0 0 0 0 0 0 0.1313 0 0 2073 0 0 0 0 0 0 55 2074 0 0 0 0 0 0 2074 0 0 0 0 0 0 0 0 0 0.1313 0 0 2074 0 0 0 0 0 0 56 2075 0 0 0 0 0 0 2075 0 0 0 0 0 0 0 0 0 0.1313 0 0 2075 0 0 0 0 0 0 57 2076 0 0 0 0 0 0 2076 0 0 0 0 0 0 0 0 0 0.1313 0 0 2076 0 0 0 0 0 0 58 2077 0 0 0 0 0 0 2077 0 0 0 0 0 0 0 0 0 0.1313 0 0 2077 0 0 0 0 0 0 59 2078 0 0 0 0 0 0 2078 0 0 0 0 0 0 0 0 0 0.1313 0 0 2078 0 0 0 0 0 0 60 2079 0 0 0 0 0 0 2079 0 0 0 0 0 0 0 0 0 0.1313 0 0 2079 0 0 0 0 0 0 61 2080 0 0 0 0 0 0 2080 0 0 0 0 0 0 0 0 0 0.1313 0 0 2080 0 0 0 0 0 0 62 2081 0 0 0 0 0 0 2081 0 0 0 0 0 0 0 0 0 0.1313 0 0 2081 0 0 0 0 0 0 63 2082 0 0 0 0 0 0 2082 0 0 0 0 0 0 0 0 0 0.1313 0 0 2082 0 0 0 0 0 0 64 2083 0 0 0 0 0 0 2083 0 0 0 0 0 0 0 0 0 0.1313 0 0 2083 0 0 0 0 0 0 65 2084 0 0 0 0 0 0 2084 0 0 0 0 0 0 0 0 0 0.1313 0 0 2084 0 0 0 0 0 0 PV 0 0 0 0 0 0 PV 0 0 0 0 0 0 0 0 PV 0 0 0 0 0 0 0 0 0 Renewable Energy Fund Economic Benefit-Cost Analysis Model 1 1 2 3 4 5 6 7 NOTICE: By default, this sheet is locked. If you need to unlock the sheet go to 'Review' in ribbon bar, select 'Unprotect Sheet', then input passcode: REFRound18 Project Description Community Nearest Fuel Community Region RE Technology Project ID Applicant Name Project Title Results NPV Benefits NPV Capital Costs B/C Ratio NPV Net Benefit Performance Displaced Electricity Displaced Electricity Displaced Petroleum Fuel Displaced Petroleum Fuel Displaced Natural Gas Displaced Natural Gas Avoided CO2 Avoided CO2 Proposed System Capital Costs Project Start Project Life Displaced Electric Displaced Heat Renewable Generation O&M (Electric) Renewable Generation O&M (Heat) Diesels OFF time Electric Capacity Electric Capacity Factor Heating Capacity Heating Capacity Factor Total Other Public Benefit Base System Diesel Generator O&M Applicant's Diesel Generator Efficiency Diesel Generation Efficiency Annual Cost Savings Entered Value CALCULATION CALCULATION Entered Value CALCULATION CALCULATION Electric Proposed Enter Value if generation changes Entered Value REFERENCE: Cell D34 Entered Value Entered Value Entered Value CALCULATION Base REFERENCE: Cell D32 REFERENCE: Worksheet 'Diesel Fuel Prices' Enter Value if Diesels are OFF CALCULATION CALCULATION CALCULATION CALCULATION Heating Proposed Entered Value REFERENCE: Cell D35 Entered Value Entered Value Entered Value CALCULATION CALCULATION Base REFERENCE: Cell D33 Entered Value Entered Value Entered Value CALCULATION CALCULATION Glennallen Railbelt North of Alaska Range Hydro (Run of River) 18021 Copper Valley Electric Association, Inc. Solomon Gulch Hydroelectric Facility Pool Raise 8618857.9825 9289996.6297 0.927756847074866 -671138.6472 Unit kWh per year total lifetime kWh gallons per year total lifetime gallons MCF per year total lifetime MCF tonnes per year total lifetime tonnes Unit $ year years kWh per year gallons displaced per year $ per year $ per year Hours per year kW % Btu/hr % 2025$ (Total over the life of the project) Size of impacted engines (select from list) 60-150kW kWh per gallon Total current annual diesel generation Project Capital Cost Electric Cost Savings Heating Cost Savings Other Public Benefits Total Cost Savings Net Benefit Renewable Generation Renewable scheduled replacement(s) (Electric) Renewable O&M (Electric) Renewable Electric Other costs Renewable Fuel Use Quantity (Biomass) Renewable Fuel Cost Total Renewable Fuel Cost (Electric) Proposed Generation Cost (Electric) Displaced Fossil Fuel Generation Avoided Generation Cost Displaced Scheduled component replacement(s) Displaced O&M Displaced Fuel Use Displaced Fuel Cost Base Generation Displaced Cost Renewable scheduled replacement(s) Renewable Heat O&M Renewable Heat Other costs Renewable Fuel Use Quantity (Heat) Renewable Fuel Cost (Heat) Total Renewable Fuel Cost (Heat) Proposed Generation Cost (Heat) Displaced Fossil Fuel Use Displaced Fossil Fuel Price Displaced Scheduled component replacement(s) Displaced O&M Displaced Fuel Cost Base Heating Displaced Cost Value 2759000 55180000 209684 4193680 0 0 2136.67996 42733.5992 Value 10192432 2030 20 2759000 0 12000 0.026246194824962 0 $/hr 0 kWh/gallon 12.5 Units $ per year $ per year $ per year $ per year $ per year $ per year Units kWh per year $ per year $ per year $ per year green tons $ per unit $ per year $ per year kWh per year $ per kWh $ per year $ per year gallons per year $ per year $ per year Units $ per year $ per year $ per year green tons/kWh/etc. $ per unit $ per year $ per year gallons per year $ per gallon $ per year $ per year $ per year $ per year <--Input <--Input <--Input <--Input <--Input <--Input <--Input <--Calculation <--Calculation <--Calculation <--Calculation <--Calculation <--Calculation <--Calculation <--Calculation <--Calculation <--Calculation <--Calculation <--Calculation <--Calculation <--Input <--Input <--Input <--Input <--Input <--Input <--Input <--Input <--Calculation <--Input <--Calculation <--Calculation REFERENCE: '999-Calc' <--Input <--Calculation 4 2025 0 0 0 0 0 2025 0 0 0 0 0 0 0.1601 0 0 0 0 0 2025 0 0 0 0 0 0 0 Comments: (Please assign comment ID and hyperlink next to applicable column/row) ID 1 2 3 4 5 6 7 5 2026 895068 0 0 0 0 -895068 2026 0 0 0 0 0 0 0.1522 0 0 0 0 0 2026 0 0 0 0 0 0 0 Description Glennallen, which would be the recipient of additional generation, is located south of the Alaska Range, but it is not on the grid and uses diesel fuel for generation, not natural gas. No fuel price is available if Rural is selected, so this region is selected to provide a better estimate of cost savings. The grant application covers the first year of three toward seeing this project to completion. Two more years will be required, 2028 and 2029, so the first full year of operations will be 2030. See page 6 of the application. Applicant notes that the expected life is 20 years, though 30 years is possible with proper maintenance. See page 22 of the application. An 8-foot pool raise will deliver 2,759,000 kWh/year. See page 19 of the application and the feasibility report. (Note that page 13 contains a typo, stating it will be 2,749,000 kWh/year.) Applicant notes that maintenance would be minimal, as O&M costs are already incurred for the existing hydropower facility. CVEA would keep additional flashboards on hand in case there is a washout and they need to be replaced. See page 24 of the application. This pool raise would use the two existing turbines, each of which is rated for 6 MW. See page 17 of the application. See Calc sheet for allocation of costs over time. Note that applicant says reconnaissance was completed, but does not provide that cost. 6 2027 895068 0 0 0 0 -895068 2027 0 0 0 0 0 0 0.1456 0 0 0 0 0 2027 0 0 0 0 0 0 0 7 2028 4201148 0 0 0 0 -4201148 2028 0 0 0 0 0 0 0.1517 0 0 0 0 0 2028 0 0 0 0 0 0 0 8 2029 4201148 0 0 0 0 -4201148 2029 0 0 0 0 0 0 0.1608 0 0 0 0 0 2029 0 0 0 0 0 0 0 9 2030 472437.9573 0 0 472437.9573 472437.9573 2030 2759000 0 0 0 0 2759000 0.1712 0 0 209684 35905.2848 472437.9573 2030 0 0 0 0 0 0 0 10 2031 494906.6351 0 0 494906.6351 494906.6351 2031 2759000 0 0 0 2759000 0.1794 0 209684 37612.9043 494906.6351 2031 0 0 0 0 0 0 11 2032 568078.6683 0 0 568078.6683 568078.6683 2032 2759000 0 0 0 0 2759000 0.2059 0 0 209684 43173.9788 568078.6683 2032 0 0 0 0 0 0 0 12 2033 629329.1104 0 0 629329.1104 629329.1104 2033 2759000 0 0 0 0 2759000 0.2281 0 0 209684 47829.0124 629329.1104 2033 0 0 0 0 0 0 0 13 2034 665197.2435 0 0 665197.2435 665197.2435 2034 2759000 0 0 0 0 2759000 0.2411 0 0 209684 50554.9905 665197.2435 2034 0 0 0 0 0 0 0 14 2035 679092.7583 0 0 679092.7583 679092.7583 2035 2759000 0 0 0 0 2759000 0.2461 0 0 209684 51611.0496 679092.7583 2035 0 0 0 0 0 0 0 15 2036 678636.748 0 0 678636.748 678636.748 2036 2759000 0 0 0 0 2759000 0.246 0 0 209684 51576.3928 678636.748 2036 0 0 0 0 0 0 0 16 2037 670610.4829 0 670610.4829 670610.4829 2037 2759000 0 0 0 2759000 0.2431 0 209684 50966.3967 670610.4829 2037 0 0 0 0 0 0 17 2038 660949.7784 0 0 660949.7784 660949.7784 2038 2759000 0 0 0 0 2759000 0.2396 0 0 209684 50232.1832 660949.7784 2038 0 0 0 0 0 0 0 18 2039 651050.389 0 0 651050.389 651050.389 2039 2759000 0 0 0 0 2759000 0.236 0 0 209684 49479.8296 651050.389 2039 0 0 0 0 0 0 0 19 2040 654725.6101 0 0 654725.6101 654725.6101 2040 2759000 0 0 0 0 2759000 0.2373 0 0 209684 49759.1464 654725.6101 2040 0 0 0 0 0 0 0 20 2041 666502.7323 0 0 666502.7323 666502.7323 2041 2759000 0 0 0 0 2759000 0.2416 0 0 209684 50654.2077 666502.7323 2041 0 0 0 0 0 0 0 21 2042 678120.2435 0 0 678120.2435 678120.2435 2042 2759000 0 0 0 0 2759000 0.2458 0 0 209684 51537.1385 678120.2435 2042 0 0 0 0 0 0 0 22 2043 698789.3481 0 0 698789.3481 698789.3481 2043 2759000 0 0 0 0 2759000 0.2533 0 0 209684 53107.9905 698789.3481 2043 0 0 0 0 0 0 0 23 2044 711685.2098 0 0 711685.2098 711685.2098 2044 2759000 0 0 0 0 2759000 0.258 0 0 209684 54088.0759 711685.2098 2044 0 0 0 0 0 0 0 24 2045 720474.418 0 0 720474.418 720474.418 2045 2759000 0 0 0 0 2759000 0.2611 0 0 209684 54756.0558 720474.418 2045 0 0 0 0 0 0 0 25 2046 733684.7469 0 0 733684.7469 733684.7469 2046 2759000 0 0 0 0 2759000 0.2659 0 0 209684 55760.0408 733684.7469 2046 0 0 0 0 0 0 0 26 2047 741155.007 0 0 741155.007 741155.007 2047 2759000 0 0 0 0 2759000 0.2686 0 0 209684 56327.7805 741155.007 2047 0 0 0 0 0 0 0 27 2048 740641.9405 0 0 740641.9405 740641.9405 2048 2759000 0 0 0 0 2759000 0.2684 0 0 209684 56288.7875 740641.9405 2048 0 0 0 0 0 0 0 28 2049 740641.9405 0 0 740641.9405 740641.9405 2049 2759000 0 0 0 0 2759000 0.2684 0 0 209684 56288.7875 740641.9405 2049 0 0 0 0 0 0 0 29 2050 0 0 0 0 0 2050 0 0 0 0 0 0 0.2684 0 0 0 0 0 2050 0 0 0 0 0 0 0 30 2051 0 0 0 0 0 2051 0 0 0 0 0 0 0.2684 0 0 0 0 0 2051 0 0 0 0 0 0 0 31 2052 0 0 0 0 0 2052 0 0 0 0 0 0 0.2684 0 0 0 0 0 2052 0 0 0 0 0 0 0 32 2053 0 0 0 0 0 2053 0 0 0 0 0 0 0.2684 0 0 0 0 0 2053 0 0 0 0 0 0 0 33 2054 0 0 0 0 0 2054 0 0 0 0 0 0 0.2684 0 0 0 0 0 2054 0 0 0 0 0 0 0 34 2055 0 0 0 0 0 2055 0 0 0 0 0 0 0.2684 0 0 0 0 0 2055 0 0 0 0 0 0 0 35 2056 0 0 0 0 0 2056 0 0 0 0 0 0 0.2684 0 0 0 0 0 2056 0 0 0 0 0 0 0 36 2057 0 0 0 0 0 2057 0 0 0 0 0 0 0.2684 0 0 0 0 0 2057 0 0 0 0 0 0 0 37 2058 0 0 0 0 0 2058 0 0 0 0 0 0 0.2684 0 0 0 0 0 2058 0 0 0 0 0 0 0 38 2059 0 0 0 0 0 2059 0 0 0 0 0 0 0.2684 0 0 0 0 0 2059 0 0 0 0 0 0 0 39 2060 0 0 0 0 0 2060 0 0 0 0 0 0 0.2684 0 0 0 0 0 2060 0 0 0 0 0 0 0 40 2061 0 0 0 0 0 2061 0 0 0 0 0 0 0.2684 0 0 0 0 0 2061 0 0 0 0 0 0 0 41 2062 0 0 0 0 0 2062 0 0 0 0 0 0 0.2684 0 0 0 0 0 2062 0 0 0 0 0 0 0 42 2063 0 0 0 0 0 2063 0 0 0 0 0 0 0.2684 0 0 0 0 0 2063 0 0 0 0 0 0 0 43 2064 0 0 0 0 0 2064 0 0 0 0 0 0 0.2684 0 0 0 0 0 2064 0 0 0 0 0 0 0 44 2065 0 0 0 0 0 2065 0 0 0 0 0 0 0.2684 0 0 0 0 0 2065 0 0 0 0 0 0 0 45 2066 0 0 0 0 0 2066 0 0 0 0 0 0 0.2684 0 0 0 0 0 2066 0 0 0 0 0 0 0 46 2067 0 0 0 0 0 2067 0 0 0 0 0 0 0.2684 0 0 0 0 0 2067 0 0 0 0 0 0 0 47 2068 0 0 0 0 0 2068 0 0 0 0 0 0 0.2684 0 0 0 0 0 2068 0 0 0 0 0 0 0 48 2069 0 0 0 0 0 2069 0 0 0 0 0 0 0.2684 0 0 0 0 0 2069 0 0 0 0 0 0 0 49 2070 0 0 0 0 0 2070 0 0 0 0 0 0 0.2684 0 0 0 0 0 2070 0 0 0 0 0 0 0 50 2071 0 0 0 0 0 2071 0 0 0 0 0 0 0.2684 0 0 0 0 0 2071 0 0 0 0 0 0 0 51 2072 0 0 0 0 0 2072 0 0 0 0 0 0 0.2684 0 0 0 0 0 2072 0 0 0 0 0 0 0 52 2073 0 0 0 0 0 2073 0 0 0 0 0 0 0.2684 0 0 0 0 0 2073 0 0 0 0 0 0 0 53 2074 0 0 0 0 0 2074 0 0 0 0 0 0 0.2684 0 0 0 0 0 2074 0 0 0 0 0 0 0 54 2075 0 0 0 0 0 2075 0 0 0 0 0 0 0.2684 0 0 0 0 0 2075 0 0 0 0 0 0 0 55 2076 0 0 0 0 0 2076 0 0 0 0 0 0 0.2684 0 0 0 0 0 2076 0 0 0 0 0 0 0 56 2077 0 0 0 0 0 2077 0 0 0 0 0 0 0.2684 0 0 0 0 0 2077 0 0 0 0 0 0 0 57 2078 0 0 0 0 0 2078 0 0 0 0 0 0 0.2684 0 0 0 0 0 2078 0 0 0 0 0 0 0 58 2079 0 0 0 0 0 2079 0 0 0 0 0 0 0.2684 0 0 0 0 0 2079 0 0 0 0 0 0 0 59 2080 0 0 0 0 0 2080 0 0 0 0 0 0 0.2684 0 0 0 0 0 2080 0 0 0 0 0 0 0 60 2081 0 0 0 0 0 2081 0 0 0 0 0 0 0.2684 0 0 0 0 0 2081 0 0 0 0 0 0 0 61 2082 0 0 0 0 0 2082 0 0 0 0 0 0 0.2684 0 0 0 0 0 2082 0 0 0 0 0 0 0 62 2083 0 0 0 0 0 2083 0 0 0 0 0 0 0.2684 0 0 0 0 0 2083 0 0 0 0 0 0 0 63 2084 0 0 0 0 0 2084 0 0 0 0 0 0 0.2684 0 0 0 0 0 2084 0 0 0 0 0 0 0 64 2085 0 0 0 0 0 2085 0 0 0 0 0 0 0.2684 0 0 0 0 0 2085 0 0 0 0 0 0 0 65 2086 0 0 0 0 0 2086 0 0 0 0 0 0 0.2684 0 0 0 0 0 2086 0 0 0 0 0 0 0 PV 9289996.6297 8618857.9825 0 0 8618857.9825 -671138.6472 PV 0 0 0 0 0 0 0 655033.2067 8618857.9825 PV 0 0 0 0 0 0 0 0 0 0 Renewable Energy Fund Economic Benefit-Cost Analysis Model 1 1 2 3 4 5 6 7 NOTICE: By default, this sheet is locked. If you need to unlock the sheet go to 'Review' in ribbon bar, select 'Unprotect Sheet', then input passcode: REFRound18 Project Description Community Nearest Fuel Community Region RE Technology Project ID Applicant Name Project Title Results NPV Benefits NPV Capital Costs B/C Ratio NPV Net Benefit Performance Displaced Electricity Displaced Electricity Displaced Petroleum Fuel Displaced Petroleum Fuel Displaced Natural Gas Displaced Natural Gas Avoided CO2 Avoided CO2 Proposed System Capital Costs Project Start Project Life Displaced Electric Displaced Heat Renewable Generation O&M (Electric) Renewable Generation O&M (Heat) Diesels OFF time Electric Capacity Electric Capacity Factor Heating Capacity Heating Capacity Factor Total Other Public Benefit Base System Diesel Generator O&M Applicant's Diesel Generator Efficiency Diesel Generation Efficiency Annual Cost Savings Entered Value CALCULATION CALCULATION Entered Value CALCULATION CALCULATION Electric Proposed Enter Value if generation changes Entered Value REFERENCE: Cell D34 Entered Value Entered Value Entered Value CALCULATION Base REFERENCE: Cell D32 REFERENCE: Worksheet 'Diesel Fuel Prices' Enter Value if Diesels are OFF CALCULATION CALCULATION CALCULATION CALCULATION Heating Proposed Entered Value REFERENCE: Cell D35 Entered Value Entered Value Entered Value CALCULATION CALCULATION Base REFERENCE: Cell D33 Entered Value Entered Value Entered Value CALCULATION CALCULATION Glennallen Railbelt North of Alaska Range Hydro (Reservoir) 18021 Copper Valley Electric Association, Inc. Solomon Gulch Hydroelectric Facility Pool Raise 9943116.9979 9339996.6297 1.06457393852605 603120.3682 Unit kWh per year total lifetime kWh gallons per year total lifetime gallons MCF per year total lifetime MCF tonnes per year total lifetime tonnes Unit $ year years kWh per year gallons displaced per year $ per year $ per year Hours per year kW % Btu/hr % 2025$ (Total over the life of the project) Size of impacted engines (select from list) 60-150kW kWh per gallon Total current annual diesel generation Project Capital Cost Electric Cost Savings Heating Cost Savings Other Public Benefits Total Cost Savings Net Benefit Renewable Generation Renewable scheduled replacement(s) (Electric) Renewable O&M (Electric) Renewable Electric Other costs Renewable Fuel Use Quantity (Biomass) Renewable Fuel Cost Total Renewable Fuel Cost (Electric) Proposed Generation Cost (Electric) Displaced Fossil Fuel Generation Avoided Generation Cost Displaced Scheduled component replacement(s) Displaced O&M Displaced Fuel Use Displaced Fuel Cost Base Generation Displaced Cost Renewable scheduled replacement(s) Renewable Heat O&M Renewable Heat Other costs Renewable Fuel Use Quantity (Heat) Renewable Fuel Cost (Heat) Total Renewable Fuel Cost (Heat) Proposed Generation Cost (Heat) Displaced Fossil Fuel Use Displaced Fossil Fuel Price Displaced Scheduled component replacement(s) Displaced O&M Displaced Fuel Cost Base Heating Displaced Cost Value 2759000 82770000 209684 6290520 0 0 2136.67996 64100.3988 Value 10242432 2030 30 2759000 102424.32 12000 0.026246194824962 0 $/hr 0 kWh/gallon 12.5 Units $ per year $ per year $ per year $ per year $ per year $ per year Units kWh per year $ per year $ per year $ per year green tons $ per unit $ per year $ per year kWh per year $ per kWh $ per year $ per year gallons per year $ per year $ per year Units $ per year $ per year $ per year green tons/kWh/etc. $ per unit $ per year $ per year gallons per year $ per gallon $ per year $ per year $ per year $ per year <--Input <--Input <--Input <--Input <--Input <--Input <--Input <--Calculation <--Calculation <--Calculation <--Calculation <--Calculation <--Calculation <--Calculation <--Calculation <--Calculation <--Calculation <--Calculation <--Calculation <--Calculation <--Input <--Input <--Input <--Input <--Input <--Input <--Input <--Input <--Calculation <--Input <--Calculation <--Calculation REFERENCE: '999-Calc' <--Input <--Calculation 4 2025 50000 0 0 0 0 -50000 2025 0 0 0 0 0 0 0.1601 0 0 0 0 0 2025 0 0 0 0 0 0 0 Comments: (Please assign comment ID and hyperlink next to applicable column/row) ID 1 2 3 4 5 6 7 5 2026 895068 0 0 0 0 -895068 2026 0 0 0 0 0 0 0.1522 0 0 0 0 0 2026 0 0 0 0 0 0 0 Description Glennallen, which would be the recipient of additional generation, is located south of the Alaska Range, but it is not on the grid and uses diesel fuel for generation, not natural gas. No fuel price is available if Rural is selected, so this region is selected to provide a better estimate of cost savings. The grant application covers the first year of three toward seeing this project to completion. Two more years will be required, 2028 and 2029, so the first full year of operations will be 2030. See page 6 of the application. Applicant notes that the expected life is 20 years, though 30 years is possible with proper maintenance. Given that the AEA analysis includes annual O&M costs equal to 1% of capital costs, it is reasonable to assume this would result in "proper maintenance" that research shows can extend the life to 30 years. An 8-foot pool raise will deliver 2,759,000 kWh/year. See page 19 of the application and the feasibility report. (Note that page 13 contains a typo, stating it will be 2,749,000 kWh/year.) AEA model assumes 1% O&M cost, consistent with railbelt assumption. This amount could represent acquisition of flashboards and occasional replacement, as needed. This pool raise would use the two existing turbines, each of which is rated for 6 MW. See page 17 of the application. See Calc sheet for allocation of costs over time. Note that applicant says reconnaissance was completed, but does not provide that cost. The AEA analysis adds $50,000 in 2025 for the reconnaissance study, which CVEA says was already completed, to reflect the full cost of the project. 6 2027 895068 0 0 0 0 -895068 2027 0 0 0 0 0 0 0.1456 0 0 0 0 0 2027 0 0 0 0 0 0 0 7 2028 4201148 0 0 0 0 -4201148 2028 0 0 0 0 0 0 0.1517 0 0 0 0 0 2028 0 0 0 0 0 0 0 8 2029 4201148 0 0 0 0 -4201148 2029 0 0 0 0 0 0 0.1608 0 0 0 0 0 2029 0 0 0 0 0 0 0 9 2030 370013.6373 0 0 370013.6373 370013.6373 2030 2759000 0 102424.32 0 102424.32 2759000 0.1712 0 0 209684 35905.2848 472437.9573 2030 0 0 0 0 0 0 0 10 2031 392482.3151 0 0 392482.3151 392482.3151 2031 2759000 102424.32 0 102424.32 2759000 0.1794 0 209684 37612.9043 494906.6351 2031 0 0 0 0 0 0 11 2032 465654.3483 0 0 465654.3483 465654.3483 2032 2759000 0 102424.32 0 102424.32 2759000 0.2059 0 0 209684 43173.9788 568078.6683 2032 0 0 0 0 0 0 0 12 2033 526904.7904 0 0 526904.7904 526904.7904 2033 2759000 0 102424.32 0 102424.32 2759000 0.2281 0 0 209684 47829.0124 629329.1104 2033 0 0 0 0 0 0 0 13 2034 562772.9235 0 0 562772.9235 562772.9235 2034 2759000 0 102424.32 0 102424.32 2759000 0.2411 0 0 209684 50554.9905 665197.2435 2034 0 0 0 0 0 0 0 14 2035 576668.4383 0 0 576668.4383 576668.4383 2035 2759000 0 102424.32 0 102424.32 2759000 0.2461 0 0 209684 51611.0496 679092.7583 2035 0 0 0 0 0 0 0 15 2036 576212.428 0 0 576212.428 576212.428 2036 2759000 0 102424.32 0 102424.32 2759000 0.246 0 0 209684 51576.3928 678636.748 2036 0 0 0 0 0 0 0 16 2037 568186.1629 0 568186.1629 568186.1629 2037 2759000 102424.32 0 102424.32 2759000 0.2431 0 209684 50966.3967 670610.4829 2037 0 0 0 0 0 0 17 2038 558525.4584 0 0 558525.4584 558525.4584 2038 2759000 0 102424.32 0 102424.32 2759000 0.2396 0 0 209684 50232.1832 660949.7784 2038 0 0 0 0 0 0 0 18 2039 548626.069 0 0 548626.069 548626.069 2039 2759000 0 102424.32 0 102424.32 2759000 0.236 0 0 209684 49479.8296 651050.389 2039 0 0 0 0 0 0 0 19 2040 552301.2901 0 0 552301.2901 552301.2901 2040 2759000 0 102424.32 0 102424.32 2759000 0.2373 0 0 209684 49759.1464 654725.6101 2040 0 0 0 0 0 0 0 20 2041 564078.4123 0 0 564078.4123 564078.4123 2041 2759000 0 102424.32 0 102424.32 2759000 0.2416 0 0 209684 50654.2077 666502.7323 2041 0 0 0 0 0 0 0 21 2042 575695.9235 0 0 575695.9235 575695.9235 2042 2759000 0 102424.32 0 102424.32 2759000 0.2458 0 0 209684 51537.1385 678120.2435 2042 0 0 0 0 0 0 0 22 2043 596365.0281 0 0 596365.0281 596365.0281 2043 2759000 0 102424.32 0 102424.32 2759000 0.2533 0 0 209684 53107.9905 698789.3481 2043 0 0 0 0 0 0 0 23 2044 609260.8898 0 0 609260.8898 609260.8898 2044 2759000 0 102424.32 0 102424.32 2759000 0.258 0 0 209684 54088.0759 711685.2098 2044 0 0 0 0 0 0 0 24 2045 618050.098 0 0 618050.098 618050.098 2045 2759000 0 102424.32 0 102424.32 2759000 0.2611 0 0 209684 54756.0558 720474.418 2045 0 0 0 0 0 0 0 25 2046 631260.4269 0 0 631260.4269 631260.4269 2046 2759000 0 102424.32 0 102424.32 2759000 0.2659 0 0 209684 55760.0408 733684.7469 2046 0 0 0 0 0 0 0 26 2047 638730.687 0 0 638730.687 638730.687 2047 2759000 0 102424.32 0 102424.32 2759000 0.2686 0 0 209684 56327.7805 741155.007 2047 0 0 0 0 0 0 0 27 2048 638217.6205 0 0 638217.6205 638217.6205 2048 2759000 0 102424.32 0 102424.32 2759000 0.2684 0 0 209684 56288.7875 740641.9405 2048 0 0 0 0 0 0 0 28 2049 638217.6205 0 0 638217.6205 638217.6205 2049 2759000 0 102424.32 0 102424.32 2759000 0.2684 0 0 209684 56288.7875 740641.9405 2049 0 0 0 0 0 0 0 29 2050 638217.6205 0 0 638217.6205 638217.6205 2050 2759000 0 102424.32 0 102424.32 2759000 0.2684 0 0 209684 56288.7875 740641.9405 2050 0 0 0 0 0 0 0 30 2051 638217.6205 0 0 638217.6205 638217.6205 2051 2759000 0 102424.32 0 102424.32 2759000 0.2684 0 0 209684 56288.7875 740641.9405 2051 0 0 0 0 0 0 0 31 2052 638217.6205 0 0 638217.6205 638217.6205 2052 2759000 0 102424.32 0 102424.32 2759000 0.2684 0 0 209684 56288.7875 740641.9405 2052 0 0 0 0 0 0 0 32 2053 638217.6205 0 0 638217.6205 638217.6205 2053 2759000 0 102424.32 0 102424.32 2759000 0.2684 0 0 209684 56288.7875 740641.9405 2053 0 0 0 0 0 0 0 33 2054 638217.6205 0 0 638217.6205 638217.6205 2054 2759000 0 102424.32 0 102424.32 2759000 0.2684 0 0 209684 56288.7875 740641.9405 2054 0 0 0 0 0 0 0 34 2055 638217.6205 0 0 638217.6205 638217.6205 2055 2759000 0 102424.32 0 102424.32 2759000 0.2684 0 0 209684 56288.7875 740641.9405 2055 0 0 0 0 0 0 0 35 2056 638217.6205 0 0 638217.6205 638217.6205 2056 2759000 0 102424.32 0 102424.32 2759000 0.2684 0 0 209684 56288.7875 740641.9405 2056 0 0 0 0 0 0 0 36 2057 638217.6205 0 0 638217.6205 638217.6205 2057 2759000 0 102424.32 0 102424.32 2759000 0.2684 0 0 209684 56288.7875 740641.9405 2057 0 0 0 0 0 0 0 37 2058 638217.6205 0 0 638217.6205 638217.6205 2058 2759000 0 102424.32 0 102424.32 2759000 0.2684 0 0 209684 56288.7875 740641.9405 2058 0 0 0 0 0 0 0 38 2059 638217.6205 0 0 638217.6205 638217.6205 2059 2759000 0 102424.32 0 102424.32 2759000 0.2684 0 0 209684 56288.7875 740641.9405 2059 0 0 0 0 0 0 0 39 2060 0 0 0 0 0 2060 0 0 0 0 0 0 0.2684 0 0 0 0 0 2060 0 0 0 0 0 0 0 40 2061 0 0 0 0 0 2061 0 0 0 0 0 0 0.2684 0 0 0 0 0 2061 0 0 0 0 0 0 0 41 2062 0 0 0 0 0 2062 0 0 0 0 0 0 0.2684 0 0 0 0 0 2062 0 0 0 0 0 0 0 42 2063 0 0 0 0 0 2063 0 0 0 0 0 0 0.2684 0 0 0 0 0 2063 0 0 0 0 0 0 0 43 2064 0 0 0 0 0 2064 0 0 0 0 0 0 0.2684 0 0 0 0 0 2064 0 0 0 0 0 0 0 44 2065 0 0 0 0 0 2065 0 0 0 0 0 0 0.2684 0 0 0 0 0 2065 0 0 0 0 0 0 0 45 2066 0 0 0 0 0 2066 0 0 0 0 0 0 0.2684 0 0 0 0 0 2066 0 0 0 0 0 0 0 46 2067 0 0 0 0 0 2067 0 0 0 0 0 0 0.2684 0 0 0 0 0 2067 0 0 0 0 0 0 0 47 2068 0 0 0 0 0 2068 0 0 0 0 0 0 0.2684 0 0 0 0 0 2068 0 0 0 0 0 0 0 48 2069 0 0 0 0 0 2069 0 0 0 0 0 0 0.2684 0 0 0 0 0 2069 0 0 0 0 0 0 0 49 2070 0 0 0 0 0 2070 0 0 0 0 0 0 0.2684 0 0 0 0 0 2070 0 0 0 0 0 0 0 50 2071 0 0 0 0 0 2071 0 0 0 0 0 0 0.2684 0 0 0 0 0 2071 0 0 0 0 0 0 0 51 2072 0 0 0 0 0 2072 0 0 0 0 0 0 0.2684 0 0 0 0 0 2072 0 0 0 0 0 0 0 52 2073 0 0 0 0 0 2073 0 0 0 0 0 0 0.2684 0 0 0 0 0 2073 0 0 0 0 0 0 0 53 2074 0 0 0 0 0 2074 0 0 0 0 0 0 0.2684 0 0 0 0 0 2074 0 0 0 0 0 0 0 54 2075 0 0 0 0 0 2075 0 0 0 0 0 0 0.2684 0 0 0 0 0 2075 0 0 0 0 0 0 0 55 2076 0 0 0 0 0 2076 0 0 0 0 0 0 0.2684 0 0 0 0 0 2076 0 0 0 0 0 0 0 56 2077 0 0 0 0 0 2077 0 0 0 0 0 0 0.2684 0 0 0 0 0 2077 0 0 0 0 0 0 0 57 2078 0 0 0 0 0 2078 0 0 0 0 0 0 0.2684 0 0 0 0 0 2078 0 0 0 0 0 0 0 58 2079 0 0 0 0 0 2079 0 0 0 0 0 0 0.2684 0 0 0 0 0 2079 0 0 0 0 0 0 0 59 2080 0 0 0 0 0 2080 0 0 0 0 0 0 0.2684 0 0 0 0 0 2080 0 0 0 0 0 0 0 60 2081 0 0 0 0 0 2081 0 0 0 0 0 0 0.2684 0 0 0 0 0 2081 0 0 0 0 0 0 0 61 2082 0 0 0 0 0 2082 0 0 0 0 0 0 0.2684 0 0 0 0 0 2082 0 0 0 0 0 0 0 62 2083 0 0 0 0 0 2083 0 0 0 0 0 0 0.2684 0 0 0 0 0 2083 0 0 0 0 0 0 0 63 2084 0 0 0 0 0 2084 0 0 0 0 0 0 0.2684 0 0 0 0 0 2084 0 0 0 0 0 0 0 64 2085 0 0 0 0 0 2085 0 0 0 0 0 0 0.2684 0 0 0 0 0 2085 0 0 0 0 0 0 0 65 2086 0 0 0 0 0 2086 0 0 0 0 0 0 0.2684 0 0 0 0 0 2086 0 0 0 0 0 0 0 PV 9339996.6297 9943116.9979 0 0 9943116.9979 603120.3682 PV 0 1783692.7255 0 0 1783692.7255 0 0 891237.539 11726809.7235 PV 0 0 0 0 0 0 0 0 0 0 Assumptions by Technology Type - REF R18 All estimates cost estimates are for the margin Wind Hydro (Reservoir) Hydro (Run of River) Hydrokinetic Biofuels Biomass Geothermal Ocean/Tidal Solar PV Solar Thermal Gas Intertie Heat Recovery Default Fuel Displacement Assumptions Railbelt North of Alaska Range Railbelt South of Alaska Range Rural NOTES on O&M and Fuel Price Model changes, PLEASE READ Project Phases Phase I Phase II Phase III Phase IV O&M Rural $ per year 2% Capital Cost 1% Capital Cost 1.35% Capital Cost 1.5% of Capital Cost 2% Capital Cost 0.5% Capital Cost 1% Capital Cost Electric Fuel Oil, Coal (GVEA) Natural Gas (CEA) Fuel Oil Name Reconnaissance Feasibility Analysis, Resource Assessment, Conceptual Design Final Design and Permitting Construction, Commissioning, Operation and Reporting O&M Railbelt $0.023/kWh 1% Capital Cost/Year 1% Capital Cost/Year 1% Capital Cost/Year 0.5% Capital Cost/Year 1% Capital Cost/Year Heat Fuel Oil Natural Gas Fuel Oil Short Name Reconnaissance Feasibility Final Design Construction Project Life years 20 50 50 20 20 20 25 20 20 50 20 Definition A preliminary general study designed to ascertain whether a feasibility study is warranted Detailed evaluation intended to assess technical, economic, financial and operational viability and to narrow focus of final design and construction. Project configuration and specifications that guide construction. Land use and resource permits and leases required for construction. Completion of project construction, start of operation and final commissioning. It also includes follow-up O&M reporting requirements. Notes Rural--average of reported O&M. RB=Eva Creek 2019-2024 (GVEA filings to RCA) Hydro RB is based on Bradley Lake O&M 2019 Rural--average of reported O&M. No commercially available products Rural=Average of reported O&M No commercially available products Rural=Average of reported O&M Rural=Average of Reported O&M RB consistent with Northern Intertie actual costs Additional Assumptions for Wind Projects: Here are the maximum capacity factors for each wind class. For reconnaissance and feasibility proposals, it is safe to use these maximums as the capacity factor assumptions. For design and construction proposals, use collected wind data and additional analysis that will better estimate actual production. Wind Class 1 2 3 4 5 6 7 Wind cost per capacity estimates ($2023) Project size (kW) 50 100 500 1000 2000 5000 http://acep.uaf.edu/media/254003/WindPower_AlaskaCaseStudy_14986579.pdf 30-m Wind Speed 0-5.1 5.1-5.9 5.9-6.5 6.5-7 7-7.4 7.4-7.9 >7.9 Wind installed cost 38223.187 26508.4512 12440.2572 9381.787 7275.7238 5429.8742 50-m Wind Speed 0-5.6 5.6-6.4 6.4-7 7-7.5 7.5-8 8-8.8 >8.8 /kW /kW /kW /kW /kW /kW REF XV Urban & >1MW 0.154 0.197 0.24 0.28 0.324 0.362 REF XV Urban & >1MW 0.154 0.197 0.24 0.28 0.324 0.362 Avoided Cost Rate Forecasts Railbelt North of Alaska Range Railbelt South of Alaska Range Natural Gas Price - Heat Railbelt South of Alaska Range AEA Natural Gas Price Forecast Heat Rate (2024 for CEA Southcentral) Fuel Cost per kWh Avoided Cost Rate/kWh* *Avoided cost rate reported by CEA, MEA, and HEA in April 2025. Average calculated for 2025s; forward years based on EIA Henry Hub. Railbelt North of Alaska Range, (GVEA Fuel Oil and Coal) Avoided Cost Rate/kWh Avoided Cost Rate/kWh *Avoided cost rate reported by GVEA April 2025; forward years based on EIA Henry Hub. Fuel oil price forecast for Fairbanks AEO 2025 Coal Delivered Price Forecast* Fuel Use** *2025-2029 Price reflects GVEA-Usibelli Coal Contract Price Agreement (Ref. TA379-13) $ / MMBtu converted to $/short ton, assuming heat content of .0073 MMBtu / lb (14.6 MMBtu / short ton), future years escalated at EIA AEO 2025 coal price forecast **Assumption: Weighted average Btu/kWh for all 2018 RCA-reported GVEA coal & oil generation (does not include purchased power, wind or solar) Unit 2025$ per kWh 2025$ per kWh $ per Mcf (2025$) 2025$ per Mcf Mcf per kWh 2025$ per kWh 2025$ per kWh 2025$ per kWh 2025$ per kWh 2025$ per gallon 2025$ per ton MMBtu per kWh 4 2025 0.1601 0.0783 7.83 2025 7.83 8.36710355675268E-03 0.0655 0.0783 2025 0.1601 0.1601 2.24 63.51 0.076 5 2026 0.1522 0.0745 7.92 2026 7.92 8.36710355675268E-03 0.0663 0.0745 2026 0.1522 0.1522 2.6163 63.51 0.076 6 2027 0.1456 0.0712 8.01 2027 8.01 8.36710355675268E-03 0.067 0.0712 2027 0.1456 0.1456 2.5873 63.51 0.076 7 2028 0.1517 0.0742 8.3461 2028 8.3461 8.36710355675268E-03 0.0698 0.0742 2028 0.1517 0.1517 2.5738 63.51 0.076 8 2029 0.1608 0.0787 8.8492 2029 8.8492 8.36710355675268E-03 0.074 0.0787 2029 0.1608 0.1608 2.5683 63.51 0.076 9 2030 0.1712 0.0838 9.4218 2030 9.4218 8.36710355675268E-03 0.0788 0.0838 2030 0.1712 0.1712 2.5807 65.5295 0.076 10 2031 0.1794 0.0878 9.8699 2031 9.8699 8.36710355675268E-03 0.0826 0.0878 2031 0.1794 0.1794 2.587 64.1437 0.076 11 2032 0.2059 0.1007 11.3292 2032 11.3292 8.36710355675268E-03 0.0948 0.1007 2032 0.2059 0.2059 2.5535 56.6461 0.076 12 2033 0.2281 0.1116 12.5507 2033 12.5507 8.36710355675268E-03 0.105 0.1116 2033 0.2281 0.2281 2.6247 56.0659 0.076 13 2034 0.2411 0.118 13.266 2034 13.266 8.36710355675268E-03 0.111 0.118 2034 0.2411 0.2411 2.6342 56.3443 0.076 14 2035 0.2461 0.1204 13.5432 2035 13.5432 8.36710355675268E-03 0.1133 0.1204 2035 0.2461 0.2461 2.649 56.0671 0.076 15 2036 0.246 0.1204 13.5341 2036 13.5341 8.36710355675268E-03 0.1132 0.1204 2036 0.246 0.246 2.658 56.4167 0.076 16 2037 0.2431 0.1189 13.374 2037 13.374 8.36710355675268E-03 0.1119 0.1189 2037 0.2431 0.2431 2.6905 55.0675 0.076 17 2038 0.2396 0.1172 13.1813 2038 13.1813 8.36710355675268E-03 0.1103 0.1172 2038 0.2396 0.2396 2.6983 55.4947 0.076 18 2039 0.236 0.1155 12.9839 2039 12.9839 8.36710355675268E-03 0.1086 0.1155 2039 0.236 0.236 2.7153 59.7661 0.076 19 2040 0.2373 0.1161 13.0572 2040 13.0572 8.36710355675268E-03 0.1093 0.1161 2040 0.2373 0.2373 2.7351 59.7063 0.076 20 2041 0.2416 0.1182 13.2921 2041 13.2921 8.36710355675268E-03 0.1112 0.1182 2041 0.2416 0.2416 2.7494 59.699 0.076 21 2042 0.2458 0.1203 13.5238 2042 13.5238 8.36710355675268E-03 0.1132 0.1203 2042 0.2458 0.2458 2.7405 59.5394 0.076 22 2043 0.2533 0.1239 13.936 2043 13.936 8.36710355675268E-03 0.1166 0.1239 2043 0.2533 0.2533 2.8032 59.722 0.076 23 2044 0.258 0.1262 14.1931 2044 14.1931 8.36710355675268E-03 0.1188 0.1262 2044 0.258 0.258 2.7678 58.4022 0.076 24 2045 0.2611 0.1278 14.3684 2045 14.3684 8.36710355675268E-03 0.1202 0.1278 2045 0.2611 0.2611 2.8 57.7477 0.076 25 2046 0.2659 0.1301 14.6319 2046 14.6319 8.36710355675268E-03 0.1224 0.1301 2046 0.2659 0.2659 2.8141 60.1043 0.076 26 2047 0.2686 0.1314 14.7809 2047 14.7809 8.36710355675268E-03 0.1237 0.1314 2047 0.2686 0.2686 2.9026 70.1764 0.076 27 2048 0.2684 0.1313 14.7706 2048 14.7706 8.36710355675268E-03 0.1236 0.1313 2048 0.2684 0.2684 2.9139 69.0111 0.076 28 2049 0.2684 0.1307 14.7022 2049 14.7022 8.36710355675268E-03 0.123 0.1307 2049 0.2672 0.2684 2.9323 68.9173 0.076 29 2050 0.2684 0.1307 14.6938 2050 14.6938 8.36710355675268E-03 0.1229 0.1307 2050 0.267 0.2684 2.9524 71.1604 0.076 30 2051 0.2684 0.1313 14.6938 2051 14.6938 8.36710355675268E-03 0.1229 0.1313 2051 0.267 0.2684 2.9323 71.1604 0.076 31 2052 0.2684 0.1313 14.6938 2052 14.6938 8.36710355675268E-03 0.1229 0.1313 2052 0.267 0.2684 2.9323 71.1604 0.076 32 2053 0.2684 0.1313 14.6938 2053 14.6938 8.36710355675268E-03 0.1229 0.1313 2053 0.267 0.2684 2.9323 71.1604 0.076 33 2054 0.2684 0.1313 14.6938 2054 14.6938 8.36710355675268E-03 0.1229 0.1313 2054 0.267 0.2684 2.9323 71.1604 0.076 34 2055 0.2684 0.1313 14.6938 2055 14.6938 8.36710355675268E-03 0.1229 0.1313 2055 0.267 0.2684 2.9323 71.1604 0.076 35 2056 0.2684 0.1313 14.6938 2056 14.6938 8.36710355675268E-03 0.1229 0.1313 2056 0.267 0.2684 2.9323 71.1604 0.076 36 2057 0.2684 0.1313 14.6938 2057 14.6938 8.36710355675268E-03 0.1229 0.1313 2057 0.267 0.2684 2.9323 71.1604 0.076 37 2058 0.2684 0.1313 14.6938 2058 14.6938 8.36710355675268E-03 0.1229 0.1313 2058 0.267 0.2684 2.9323 71.1604 0.076 38 2059 0.2684 0.1313 14.6938 2059 14.6938 8.36710355675268E-03 0.1229 0.1313 2059 0.267 0.2684 2.9323 71.1604 0.076 39 2060 0.2684 0.1313 14.6938 2060 14.6938 8.36710355675268E-03 0.1229 0.1313 2060 0.267 0.2684 2.9323 71.1604 0.076 40 2061 0.2684 0.1313 14.6938 2061 14.6938 8.36710355675268E-03 0.1229 0.1313 2061 0.267 0.2684 2.9323 71.1604 0.076 41 2062 0.2684 0.1313 14.6938 2062 14.6938 8.36710355675268E-03 0.1229 0.1313 2062 0.267 0.2684 2.9323 71.1604 0.076 42 2063 0.2684 0.1313 14.6938 2063 14.6938 8.36710355675268E-03 0.1229 0.1313 2063 0.267 0.2684 2.9323 71.1604 0.076 43 2064 0.2684 0.1313 14.6938 2064 14.6938 8.36710355675268E-03 0.1229 0.1313 2064 0.267 0.2684 2.9323 71.1604 0.076 44 2065 0.2684 0.1313 14.6938 2065 14.6938 8.36710355675268E-03 0.1229 0.1313 2065 0.267 0.2684 2.9323 71.1604 0.076 45 2066 0.2684 0.1313 14.6938 2066 14.6938 8.36710355675268E-03 0.1229 0.1313 2066 0.267 0.2684 2.9323 71.1604 0.076 46 2067 0.2684 0.1313 14.6938 2067 14.6938 8.36710355675268E-03 0.1229 0.1313 2067 0.267 0.2684 2.9323 71.1604 0.076 47 2068 0.2684 0.1313 14.6938 2068 14.6938 8.36710355675268E-03 0.1229 0.1313 2068 0.267 0.2684 2.9323 71.1604 0.076 48 2069 0.2684 0.1313 14.6938 2069 14.6938 8.36710355675268E-03 0.1229 0.1313 2069 0.267 0.2684 2.9323 71.1604 0.076 49 2070 0.2684 0.1313 14.6938 2070 14.6938 8.36710355675268E-03 0.1229 0.1313 2070 0.267 0.2684 2.9323 71.1604 0.076 50 2071 0.2684 0.1313 14.6938 2071 14.6938 8.36710355675268E-03 0.1229 0.1313 2071 0.267 0.2684 2.9323 71.1604 0.076 51 2072 0.2684 0.1313 14.6938 2072 14.6938 8.36710355675268E-03 0.1229 0.1313 2072 0.267 0.2684 2.9323 71.1604 0.076 52 2073 0.2684 0.1313 14.6938 2073 14.6938 8.36710355675268E-03 0.1229 0.1313 2073 0.267 0.2684 2.9323 71.1604 0.076 53 2074 0.2684 0.1313 14.6938 2074 14.6938 8.36710355675268E-03 0.1229 0.1313 2074 0.267 0.2684 2.9323 71.1604 0.076 54 2075 0.2684 0.1313 14.6938 2075 14.6938 8.36710355675268E-03 0.1229 0.1313 2075 0.267 0.2684 2.9323 71.1604 0.076 55 2076 0.2684 0.1313 14.6938 2076 14.6938 8.36710355675268E-03 0.1229 0.1313 2076 0.267 0.2684 2.9323 71.1604 0.076 56 2077 0.2684 0.1313 14.6938 2077 14.6938 8.36710355675268E-03 0.1229 0.1313 2077 0.267 0.2684 2.9323 71.1604 0.076 57 2078 0.2684 0.1313 14.6938 2078 14.6938 8.36710355675268E-03 0.1229 0.1313 2078 0.267 0.2684 2.9323 71.1604 0.076 58 2079 0.2684 0.1313 14.6938 2079 14.6938 8.36710355675268E-03 0.1229 0.1313 2079 0.267 0.2684 2.9323 71.1604 0.076 59 2080 0.2684 0.1313 14.6938 2080 14.6938 8.36710355675268E-03 0.1229 0.1313 2080 0.267 0.2684 2.9323 71.1604 0.076 60 2081 0.2684 0.1313 14.6938 2081 14.6938 8.36710355675268E-03 0.1229 0.1313 2081 0.267 0.2684 2.9323 71.1604 0.076 61 2082 0.2684 0.1313 14.6938 2082 14.6938 8.36710355675268E-03 0.1229 0.1313 2082 0.267 0.2684 2.9323 71.1604 0.076 62 2083 0.2684 0.1313 14.6938 2083 14.6938 8.36710355675268E-03 0.1229 0.1313 2083 0.267 0.2684 2.9323 71.1604 0.076 63 2084 0.2684 0.1313 14.6938 2084 14.6938 8.36710355675268E-03 0.1229 0.1313 2084 0.267 0.2684 2.9323 71.1604 0.076 64 2085 0.2684 0.1313 14.6938 2085 14.6938 8.36710355675268E-03 0.1229 0.1313 2085 0.267 0.2684 2.9323 71.1604 0.076 65 2086 0.2684 0.1313 14.6938 2086 14.6938 8.36710355675268E-03 0.1229 0.1313 2086 0.267 0.2684 2.9323 71.1604 0.076 66 2087 0.26844579214492 0.131347110367366 14.6938063476615 2087 14.6938063476615 8.36710355675268E-03 0.122944599353753 0.131347110367366 2087 0.267049573105062 0.26844579214492 2.93232822724427 71.1603924748777 0.076 67 2088 0.26844579214492 0.131347110367366 14.6938063476615 2088 14.6938063476615 8.36710355675268E-03 0.122944599353753 0.131347110367366 2088 0.267049573105062 0.26844579214492 2.93232822724427 71.1603924748777 0.076 68 2089 0.26844579214492 0.131347110367366 14.6938063476615 2089 14.6938063476615 8.36710355675268E-03 0.122944599353753 0.131347110367366 2089 0.267049573105062 0.26844579214492 2.93232822724427 71.1603924748777 0.076 69 2090 0.26844579214492 0.131347110367366 14.6938063476615 2090 14.6938063476615 8.36710355675268E-03 0.122944599353753 0.131347110367366 2090 0.267049573105062 0.26844579214492 2.93232822724427 71.1603924748777 0.076 Community Fuel Oil Price Projections for Electric Sector Rural (0) Urban (1) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 1 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 Utility TDX Adak Akhiok/Kaguyak Electric Akiachak Native Community Electric Co. Akiak, City of Akutan Electric Utility Alaska Village Electric Cooperative Alaska Power Company Alaska Village Electric Cooperative North Slope Borough Inside Passage Electric Cooperative Aniak Light & Power Company Alaska Village Electric Cooperative Arctic Village Council Andreanof Electric Corporation Atmautluak Joint Utilities North Slope Borough Beaver Joint Utilities Alaska Village Electric Cooperative Alaska Power Company Birch Creek Tribal Council Alaska Village Electric Cooperative Buckland, City of Central Electric, Inc. Chalkyitsik Village Energy System Naterkaq Light Plant Chenega IRA Village Council Alaska Village Electric Cooperative Chignik Electric Chignik Lagoon Power Utility Chignik Lake Electric Utility, Inc. (11) Inside Passage Electric Cooperative Alaska Power Company Chitina Electric Inc. Middle Kuskokwim Electric Cooperative Circle Electric Utility Alaska Power Company G & K Cordova Electric Cooperative, Inc. Alaska Power Company Middle Kuskokwim Electric Cooperative Ipnatchiaq Electric Company Nushagak Electric Cooperative Diomede Joint Utilities Alaska Power Company Alaska Power Company Alaska Village Electric Cooperative Egegik Light and Power Ekwok Electric (10) Elfin Cove Electric Utility Alaska Village Electric Cooperative Alaska Village Electric Cooperative Golden Valley Electric Association False Pass Electric Association (9) Gwitchyaa Zhee Utilities Galena, City of Alaska Village Electric Cooperative Golovin Power Utilities Alaska Village Electric Cooperative Alaska Village Electric Cooperative Gustavus Electric Company Alaska Power Company Alaska Power Company Alaska Power Company Alaska Village Electric Cooperative Inside Passage Electric Cooperative Alaska Village Electric Cooperative Hughes Power & Light Alaska Village Electric Cooperative Alaska Power Company Igiugig Electric Company I-N-N Electric Cooperative Utility direct communication Inside Passage Electric Cooperative North Slope Borough Alaska Village Electric Cooperative Alaska Village Electric Cooperative Alutiiq Power Company Alaska Village Electric Cooperative Ketchikan Public Utilities Alaska Village Electric Cooperative King Cove, City of Kipnuk Light Plant Alaska Village Electric Cooperative Alaska Power Company Inside Passage Electric Cooperative Kobuk Valley Electric Company Kodiak Energy Association Kokhanok Village Council Koliganek Village Council Puvurnaq Power Company Kotlik Electric Services Kotzebue Electric Association Alaska Village Electric Cooperative Koyukuk, City of Kwethluk, Inc. Kwig Power Company Larsen Bay Utility Company Levelock Electric Cooperative Lime Village Electric Utility Alaska Village Electric Cooperative Manley Utility Company Manokotak Power Company Alaska Village Electric Cooperative McGrath Light & Power Alaska Village Electric Cooperative Alaska Power Company Metlakatla Power & Light Alaska Village Electric Cooperative Alaska Village Electric Cooperative Naknek Electric Association Napakiak Ircinraq Power Company Napaskiak Electric Utility Alaska Power Company Nelson Lagoon Electric Cooperative Alaska Village Electric Cooperative Unqusrag Power Company Alaska Village Electric Cooperative Nikolai Light & Power Umnak Power Company Alaska Village Electric Cooperative Nome Joint Utility System Alaska Village Electric Cooperative Alaska Power Company North Slope Borough Alaska Village Electric Cooperative Nunam Iqua Electric Company Alaska Village Electric Cooperative Alaska Village Electric Cooperative Ouzinkie, City of Pedro Bay Village Council City of Pelican Native Village of Perryville City of Petersburg Pilot Point Electrical Alaska Village Electric Cooperative Alaska Village Electric Cooperative Platinum, City of North Slope Borough North Slope Borough Tanalian Electric Cooperative Port Heiden, City of Alaska Village Electric Cooperative Middle Kuskokwim Electric Cooperative Ruby, City of Alaska Village Electric Cooperative Sand Point Electric Company Alaska Village Electric Cooperative Alaska Village Electric Cooperative Alaska Village Electric Cooperative Alaska Village Electric Cooperative Alaska Village Electric Cooperative Alaska Village Electric Cooperative Alaska Village Electric Cooperative City & Borough of Sitka Alaska Power Company Alaska Power Company Middle Kuskokwim Electric Cooperative City of St. George Alaska Village Electric Cooperative Alaska Village Electric Cooperative St. Paul Municipal Electrical Utility Alaska Village Electric Cooperative Middle Kuskokwim Electric Cooperative Takotna Community Association Utilities Tanana Power Company Tatitlek Electric Utility Alaska Village Electric Cooperative Tenakee Springs, City of Alaska Power Company Alaska Power Company Alaska Village Electric Cooperative Alaska Power Company Alaska Village Electric Cooperative Tuluksak Traditional Power Utility (11) Tuntutuliak Community Service Assoc. Alaska Village Electric Cooperative Twin Hills Village Council Unalakleet Valley Electrical Cooperative Unalaska Electric Utility Village of Venetie North Slope Borough Alaska Village Electric Cooperative Alaska Power Company White Mountain Utilities City of Wrangell Alaska Village Electric Cooperative Community Name Adak Akhiok Akiachak Akiak Akutan Alakanuk Allakaket, Alatna Ambler Anaktuvuk Pass Angoon Aniak Anvik Arctic Village Atka Atmautluak Atqasuk Beaver Bethel Bettles, Evansville Birch Creek Brevig Mission Buckland Central Chalkyitsik Chefornak Chenega Bay Chevak Chignik Chignik Lagoon Chignik Lake Chilkat Valley Chistochina Chitina Chuathbaluk Circle Coffman Cove Cold Bay Cordova Craig Crooked Creek Deering Dillingham Diomede Dot Lake Eagle, Eagle Village Eek Egegik Ekwok Elfin Cove Elim Emmonak Fairbanks False Pass Fort Yukon Galena Gambell Golovin Goodnews Bay Grayling Gustavus Haines Healy Lake Hollis Holy Cross Hoonah Hooper Bay Hughes Huslia Hydaburg Igiugig Iliamna-Newhalen-Nondalton Juneau Kake Kaktovik Kalskag Kaltag Karluk Kasigluk Ketchikan Kiana King Cove Kipnuk Kivalina Klawock Klukwan Kobuk Kodiak Kokhanok Koliganek-New Koliganek Kongiganak Kotlik Kotzebue Koyuk Koyukuk Kwethluk Kwigillingok Larsen Bay Levelock Lime Village Lower Kalskag Manley Hot Springs Manokotak Marshall McGrath Mekoryuk Mentasta Metlakatla Minto Mountain Village Naknek-South Naknek-King Salmon Napakiak Napaskiak Naukati Nelson Lagoon New Stuyahok Newtok Nightmute Nikolai Nikolski Noatak Nome Noorvik Northway Nuiqsut Nulato Nunam Iqua Nunapitchuk Old Harbor Ouzinkie Pedro Bay Pelican Perryville Petersburg Pilot Point Pilot Station Pitkas Point Platinum Point Hope Point Lay Port Alsworth Port Heiden Quinhagak Red Devil Ruby Russian Mission Sand Point Savoonga Scammon Bay Selawik Shageluk Shaktoolik Shishmaref Shungnak Sitka Skagway Slana Sleetmute St. George St. Mary's St. Michael St. Paul Stebbins Stony River Takotna Tanana Tatitlek Teller Tenakee Springs Tetlin Thorne Bay Togiak Tok Toksook Bay Tuluksak Tuntutuliak Tununak Twin Hills Unalakleet Unalaska Venetie Wainwright Wales Whale Pass White Mountain Wrangell Yakutat Proxy / Source (if applicable) Venetie Venetie Fort Yukon Pilot Point GVEA COPA (April 2025) AELP COPA (April 2025) Juneau Cold Bay Ouzinkie Karluk Stony River Juneau Iliamna-Newhalen-Nondalton Chignik Whale Pass Goodnews Bay Juneau Whale Pass 3 2025 5.71 3.41 4.71 9.5 4.77 5.1 5.88 6.3 6.38 3.24 4.65 4.09 7.77 5.33 4.87 7.41 7.36 4.59 4.64 7.36 4.93 5.06 3.8 6.8 5.04 5.85 4.5 4.5 4.87 3.94 3.24 2.85 3.53 4.47 3.7 3.03 7.19 3.24 3.03 4.47 4.97 3.54 3.18 2.79 3.68 4.8 5.2 4.91 5.71 5.12 5.1 2.24 3.63 6.8 4.1 5.28 4.07 4.26 4.24 4.73 3.66 3.93 3.03 4.15 3.24 4.51 4.94 4.04 3.03 9.22 4.58 3.13 3.24 5.73 5.26 4.09 5.85 4.93 3.13 5.26 7.19 4.76 5.14 3.03 3.24 8.96 4.17 6.5 5.16 4.7 4.55 3.39 5.25 4.83 5.08 3.22 5.85 4.98 4.47 5.26 4.11 3.72 4.21 5.12 4.43 2.85 3.13 3.66 4.02 3.59 0.54 5.04 3.03 5.33 4.91 5.49 4.55 7.76 8.51 10.72 3.59 5.3 3.03 5.26 4.15 4.96 4.93 4.27 4.17 4.58 3.55 4.5 3.03 5.2 3.96 4.02 4.26 5.68 5.74 5.57 4.05 4.61 4.47 7.02 4.02 3.9 5.19 4.9 4.98 3.89 4.88 4.5 8.96 3.13 3.66 2.85 4.47 10.99 4.02 4.71 6.55 4.71 4.47 5.66 3.89 5.65 5.18 4.05 2.79 3.03 4.48 2.79 4.55 12.44 4.95 4.55 4.48 4.24 2.97 7.36 5.67 5.12 3.03 3.08 3.03 4.14 4 2026 6.6693 3.9829 5.5013 11.0961 5.5714 5.9568 6.8679 7.3584 7.4519 3.7843 5.4312 4.7771 9.0754 6.2255 5.6882 8.6549 8.5965 5.3611 5.4195 8.5965 5.7583 5.9101 4.4384 7.9424 5.8867 6.8328 5.256 5.256 5.6882 4.6019 3.7843 3.3288 4.1231 5.221 4.3216 3.5391 8.398 3.7843 3.5391 5.221 5.805 4.1347 3.7143 3.2587 4.2983 5.6064 6.0736 5.7349 6.6693 5.9802 5.9568 2.6163 4.2399 7.9424 4.7888 6.1671 4.7538 4.9757 4.9523 5.5247 4.2749 4.5903 3.5391 4.8472 3.7843 5.2677 5.7699 4.7187 3.5391 10.769 5.3495 3.6559 3.7843 6.6927 6.1437 4.7771 6.8328 5.7583 3.6559 6.1437 8.398 5.5597 6.0035 3.5391 3.7843 10.4653 4.8706 7.592 6.0269 5.4896 5.3144 3.9595 6.132 5.6415 5.9335 3.761 6.8328 5.8167 5.221 6.1437 4.8005 4.345 4.9173 5.9802 5.1743 3.3288 3.6559 4.2749 4.6954 4.1931 0.6307 5.8867 3.5391 6.2255 5.7349 6.4124 5.3144 9.0637 9.9397 12.521 4.1931 6.1904 3.5391 6.1437 4.8472 5.7933 5.7583 4.9874 4.8706 5.3495 4.1464 5.256 3.5391 6.0736 4.6253 4.6954 4.9757 6.6343 6.7044 6.5058 4.7304 5.3845 5.221 8.1994 4.6954 4.5552 6.0619 5.7232 5.8167 4.5435 5.6999 5.256 10.4653 3.6559 4.2749 3.3288 5.221 12.8364 4.6954 5.5013 7.6504 5.5013 5.221 6.6109 4.5435 6.5992 6.0503 4.7304 3.2587 3.5391 5.2327 3.2587 5.3144 14.53 5.7816 5.3144 5.2327 4.9523 3.469 8.5965 6.6226 5.9802 3.5391 3.5975 3.5391 4.8355 5 2027 6.5953 3.9387 5.4403 10.9729 5.5096 5.8907 6.7917 7.2768 7.3692 3.7423 5.371 4.7241 8.9747 6.1564 5.6251 8.5589 8.5011 5.3016 5.3594 8.5011 5.6944 5.8445 4.3892 7.8543 5.8214 6.757 5.1977 5.1977 5.6251 4.5509 3.7423 3.2919 4.0773 5.163 4.2737 3.4998 8.3048 3.7423 3.4998 5.163 5.7406 4.0889 3.673 3.2226 4.2506 5.5442 6.0062 5.6713 6.5953 5.9138 5.8907 2.5873 4.1928 7.8543 4.7357 6.0986 4.701 4.9205 4.8974 5.4634 4.2275 4.5393 3.4998 4.7934 3.7423 5.2092 5.7059 4.6664 3.4998 10.6495 5.2901 3.6153 3.7423 6.6184 6.0755 4.7241 6.757 5.6944 3.6153 6.0755 8.3048 5.498 5.9369 3.4998 3.7423 10.3492 4.8165 7.5078 5.96 5.4287 5.2554 3.9156 6.064 5.5789 5.8676 3.7192 6.757 5.7521 5.163 6.0755 4.7472 4.2968 4.8627 5.9138 5.1168 3.2919 3.6153 4.2275 4.6433 4.1466 0.6237 5.8214 3.4998 6.1564 5.6713 6.3412 5.2554 8.9631 9.8294 12.3821 4.1466 6.1217 3.4998 6.0755 4.7934 5.729 5.6944 4.932 4.8165 5.2901 4.1004 5.1977 3.4998 6.0062 4.574 4.6433 4.9205 6.5606 6.6299 6.4336 4.6779 5.3247 5.163 8.1084 4.6433 4.5047 5.9947 5.6597 5.7521 4.4931 5.6366 5.1977 10.3492 3.6153 4.2275 3.2919 5.163 12.6939 4.6433 5.4403 7.5655 5.4403 5.163 6.5375 4.4931 6.526 5.9831 4.6779 3.2226 3.4998 5.1746 3.2226 5.2554 14.3687 5.7175 5.2554 5.1746 4.8974 3.4305 8.5011 6.5491 5.9138 3.4998 3.5575 3.4998 4.7819 6 2028 6.5608 3.9181 5.4118 10.9155 5.4808 5.8599 6.7561 7.2387 7.3307 3.7228 5.3429 4.6994 8.9278 6.1242 5.5957 8.5141 8.4567 5.2739 5.3314 8.4567 5.6646 5.814 4.3662 7.8132 5.791 6.7217 5.1705 5.1705 5.5957 4.5271 3.7228 3.2747 4.056 5.1361 4.2513 3.4815 8.2613 3.7228 3.4815 5.1361 5.7106 4.0675 3.6538 3.2057 4.2283 5.5152 5.9748 5.6416 6.5608 5.8829 5.8599 2.5738 4.1709 7.8132 4.7109 6.0667 4.6765 4.8948 4.8718 5.4348 4.2054 4.5156 3.4815 4.7684 3.7228 5.182 5.6761 4.642 3.4815 10.5938 5.2624 3.5964 3.7228 6.5838 6.0438 4.6994 6.7217 5.6646 3.5964 6.0438 8.2613 5.4693 5.9059 3.4815 3.7228 10.2951 4.7914 7.4685 5.9289 5.4003 5.228 3.8951 6.0323 5.5497 5.8369 3.6998 6.7217 5.722 5.1361 6.0438 4.7224 4.2743 4.8373 5.8829 5.0901 3.2747 3.5964 4.2054 4.619 4.1249 0.6205 5.791 3.4815 6.1242 5.6416 6.308 5.228 8.9163 9.778 12.3173 4.1249 6.0897 3.4815 6.0438 4.7684 5.6991 5.6646 4.9063 4.7914 5.2624 4.079 5.1705 3.4815 5.9748 4.5501 4.619 4.8948 6.5263 6.5953 6.4 4.6535 5.2969 5.1361 8.066 4.619 4.4811 5.9633 5.6301 5.722 4.4696 5.6071 5.1705 10.2951 3.5964 4.2054 3.2747 5.1361 12.6276 4.619 5.4118 7.526 5.4118 5.1361 6.5034 4.4696 6.4919 5.9518 4.6535 3.2057 3.4815 5.1475 3.2057 5.228 14.2936 5.6876 5.228 5.1475 4.8718 3.4125 8.4567 6.5149 5.8829 3.4815 3.5389 3.4815 4.7569 7 2029 6.5469 3.9098 5.4003 10.8924 5.4691 5.8475 6.7418 7.2234 7.3151 3.7149 5.3315 4.6895 8.9088 6.1112 5.5838 8.4961 8.4388 5.2628 5.3201 8.4388 5.6526 5.8016 4.357 7.7967 5.7787 6.7074 5.1596 5.1596 5.5838 4.5175 3.7149 3.2677 4.0474 5.1252 4.2423 3.4741 8.2438 3.7149 3.4741 5.1252 5.6985 4.0589 3.6461 3.1989 4.2194 5.5035 5.9622 5.6297 6.5469 5.8704 5.8475 2.5683 4.162 7.7967 4.7009 6.0539 4.6665 4.8844 4.8615 5.4233 4.1964 4.506 3.4741 4.7583 3.7149 5.171 5.6641 4.6321 3.4741 10.5714 5.2513 3.5888 3.7149 6.5698 6.031 4.6895 6.7074 5.6526 3.5888 6.031 8.2438 5.4577 5.8934 3.4741 3.7149 10.2733 4.7812 7.4527 5.9163 5.3889 5.2169 3.8869 6.0195 5.5379 5.8246 3.692 6.7074 5.7099 5.1252 6.031 4.7124 4.2652 4.8271 5.8704 5.0793 3.2677 3.5888 4.1964 4.6092 4.1162 0.6191 5.7787 3.4741 6.1112 5.6297 6.2947 5.2169 8.8974 9.7573 12.2912 4.1162 6.0768 3.4741 6.031 4.7583 5.687 5.6526 4.8959 4.7812 5.2513 4.0703 5.1596 3.4741 5.9622 4.5404 4.6092 4.8844 6.5125 6.5813 6.3864 4.6436 5.2857 5.1252 8.0489 4.6092 4.4716 5.9507 5.6182 5.7099 4.4602 5.5953 5.1596 10.2733 3.5888 4.1964 3.2677 5.1252 12.6008 4.6092 5.4003 7.51 5.4003 5.1252 6.4896 4.4602 6.4781 5.9392 4.6436 3.1989 3.4741 5.1366 3.1989 5.2169 14.2633 5.6755 5.2169 5.1366 4.8615 3.4053 8.4388 6.501 5.8704 3.4741 3.5314 3.4741 4.7468 8 2030 6.5784 3.9286 5.4263 10.9448 5.4954 5.8756 6.7742 7.2581 7.3503 3.7327 5.3572 4.712 8.9517 6.1406 5.6106 8.5369 8.4793 5.288 5.3457 8.4793 5.6798 5.8295 4.3779 7.8341 5.8065 6.7397 5.1844 5.1844 5.6106 4.5392 3.7327 3.2834 4.0668 5.1498 4.2627 3.4908 8.2835 3.7327 3.4908 5.1498 5.7258 4.0784 3.6636 3.2143 4.2397 5.53 5.9908 5.6567 6.5784 5.8986 5.8756 2.5807 4.1821 7.8341 4.7235 6.083 4.689 4.9079 4.8848 5.4493 4.2166 4.5277 3.4908 4.7811 3.7327 5.1959 5.6913 4.6544 3.4908 10.6222 5.2765 3.606 3.7327 6.6014 6.0599 4.712 6.7397 5.6798 3.606 6.0599 8.2835 5.4839 5.9217 3.4908 3.7327 10.3226 4.8042 7.4885 5.9447 5.4148 5.242 3.9056 6.0484 5.5645 5.8526 3.7097 6.7397 5.7374 5.1498 6.0599 4.735 4.2857 4.8503 5.8986 5.1037 3.2834 3.606 4.2166 4.6314 4.136 0.6221 5.8065 3.4908 6.1406 5.6567 6.3249 5.242 8.9401 9.8042 12.3503 4.136 6.106 3.4908 6.0599 4.7811 5.7143 5.6798 4.9194 4.8042 5.2765 4.0899 5.1844 3.4908 5.9908 4.5622 4.6314 4.9079 6.5438 6.6129 6.4171 4.6659 5.3111 5.1498 8.0876 4.6314 4.4931 5.9793 5.6452 5.7374 4.4816 5.6222 5.1844 10.3226 3.606 4.2166 3.2834 5.1498 12.6614 4.6314 5.4263 7.5461 5.4263 5.1498 6.5208 4.4816 6.5093 5.9678 4.6659 3.2143 3.4908 5.1613 3.2143 5.242 14.3319 5.7028 5.242 5.1613 4.8848 3.4217 8.4793 6.5323 5.8986 3.4908 3.5484 3.4908 4.7696 9 2031 6.5947 3.9383 5.4397 10.9719 5.509 5.8902 6.791 7.2761 7.3685 3.742 5.3704 4.7237 8.9738 6.1558 5.6245 8.5581 8.5003 5.3011 5.3589 8.5003 5.6938 5.844 4.3887 7.8535 5.8209 6.7564 5.1972 5.1972 5.6245 4.5504 3.742 3.2916 4.0769 5.1626 4.2733 3.4994 8.304 3.742 3.4994 5.1626 5.74 4.0885 3.6727 3.2223 4.2502 5.5437 6.0057 5.6707 6.5947 5.9133 5.8902 2.587 4.1924 7.8535 4.7352 6.098 4.7006 4.92 4.8969 5.4628 4.2271 4.5389 3.4994 4.793 3.742 5.2087 5.7054 4.6659 3.4994 10.6485 5.2896 3.6149 3.742 6.6178 6.0749 4.7237 6.7564 5.6938 3.6149 6.0749 8.304 5.4975 5.9364 3.4994 3.742 10.3482 4.8161 7.5071 5.9595 5.4282 5.2549 3.9152 6.0634 5.5783 5.8671 3.7189 6.7564 5.7516 5.1626 6.0749 4.7468 4.2964 4.8623 5.9133 5.1164 3.2916 3.6149 4.2271 4.6428 4.1462 0.6237 5.8209 3.4994 6.1558 5.6707 6.3406 5.2549 8.9623 9.8285 12.3809 4.1462 6.1211 3.4994 6.0749 4.793 5.7285 5.6938 4.9316 4.8161 5.2896 4.1 5.1972 3.4994 6.0057 4.5735 4.6428 4.92 6.56 6.6293 6.433 4.6775 5.3242 5.1626 8.1076 4.6428 4.5042 5.9941 5.6592 5.7516 4.4927 5.6361 5.1972 10.3482 3.6149 4.2271 3.2916 5.1626 12.6927 4.6428 5.4397 7.5648 5.4397 5.1626 6.5369 4.4927 6.5254 5.9826 4.6775 3.2223 3.4994 5.1741 3.2223 5.2549 14.3674 5.7169 5.2549 5.1741 4.8969 3.4302 8.5003 6.5485 5.9133 3.4994 3.5572 3.4994 4.7814 10 2032 6.5091 3.8872 5.3692 10.8296 5.4376 5.8138 6.7029 7.1817 7.2729 3.6935 5.3008 4.6624 8.8575 6.076 5.5516 8.4471 8.3901 5.2324 5.2894 8.3901 5.62 5.7682 4.3318 7.7517 5.7454 6.6687 5.1298 5.1298 5.5516 4.4914 3.6935 3.2489 4.024 5.0956 4.2178 3.4541 8.1963 3.6935 3.4541 5.0956 5.6656 4.0354 3.6251 3.1805 4.195 5.4718 5.9278 5.5972 6.5091 5.8366 5.8138 2.5535 4.138 7.7517 4.6738 6.019 4.6396 4.8562 4.8334 5.392 4.1722 4.48 3.4541 4.7308 3.6935 5.1412 5.6314 4.6054 3.4541 10.5104 5.221 3.5681 3.6935 6.5319 5.9962 4.6624 6.6687 5.62 3.5681 5.9962 8.1963 5.4262 5.8594 3.4541 3.6935 10.214 4.7536 7.4097 5.8822 5.3578 5.1868 3.8644 5.9848 5.506 5.791 3.6707 6.6687 5.677 5.0956 5.9962 4.6852 4.2406 4.7992 5.8366 5.05 3.2489 3.5681 4.1722 4.5826 4.0924 0.6156 5.7454 3.4541 6.076 5.5972 6.2584 5.1868 8.8461 9.701 12.2203 4.0924 6.0418 3.4541 5.9962 4.7308 5.6542 5.62 4.8676 4.7536 5.221 4.0468 5.1298 3.4541 5.9278 4.5142 4.5826 4.8562 6.4749 6.5433 6.3496 4.6168 5.2552 5.0956 8.0025 4.5826 4.4458 5.9164 5.5858 5.677 4.4344 5.563 5.1298 10.214 3.5681 4.1722 3.2489 5.0956 12.5281 4.5826 5.3692 7.4667 5.3692 5.0956 6.4521 4.4344 6.4407 5.905 4.6168 3.1805 3.4541 5.107 3.1805 5.1868 14.181 5.6428 5.1868 5.107 4.8334 3.3857 8.3901 6.4635 5.8366 3.4541 3.5111 3.4541 4.7194 11 2033 6.6906 3.9956 5.5189 11.1315 5.5892 5.9759 6.8898 7.382 7.4757 3.7964 5.4486 4.7924 9.1044 6.2454 5.7064 8.6826 8.624 5.3783 5.4369 8.624 5.7767 5.929 4.4526 7.9678 5.9056 6.8547 5.2728 5.2728 5.7064 4.6167 3.7964 3.3395 4.1362 5.2377 4.3354 3.5504 8.4248 3.7964 3.5504 5.2377 5.8235 4.148 3.7261 3.2692 4.312 5.6243 6.093 5.7532 6.6906 5.9993 5.9759 2.6247 4.2534 7.9678 4.8041 6.1868 4.769 4.9916 4.9682 5.5423 4.2886 4.6049 3.5504 4.8627 3.7964 5.2845 5.7884 4.7338 3.5504 10.8034 5.3666 3.6675 3.7964 6.7141 6.1633 4.7924 6.8547 5.7767 3.6675 6.1633 8.4248 5.5775 6.0227 3.5504 3.7964 10.4988 4.8862 7.6163 6.0462 5.5072 5.3314 3.9722 6.1516 5.6595 5.9524 3.773 6.8547 5.8353 5.2377 6.1633 4.8158 4.3589 4.933 5.9993 5.1908 3.3395 3.6675 4.2886 4.7104 4.2065 0.6327 5.9056 3.5504 6.2454 5.7532 6.4328 5.3314 9.0927 9.9715 12.561 4.2065 6.2102 3.5504 6.1633 4.8627 5.8118 5.7767 5.0033 4.8862 5.3666 4.1597 5.2728 3.5504 6.093 4.6401 4.7104 4.9916 6.6555 6.7258 6.5266 4.7455 5.4017 5.2377 8.2256 4.7104 4.5698 6.0813 5.7415 5.8353 4.5581 5.7181 5.2728 10.4988 3.6675 4.2886 3.3395 5.2377 12.8774 4.7104 5.5189 7.6749 5.5189 5.2377 6.632 4.5581 6.6203 6.0696 4.7455 3.2692 3.5504 5.2494 3.2692 5.3314 14.5764 5.8001 5.3314 5.2494 4.9682 3.4801 8.624 6.6438 5.9993 3.5504 3.609 3.5504 4.851 12 2034 6.7148 4.0101 5.5389 11.1718 5.6094 5.9975 6.9148 7.4087 7.5028 3.8102 5.4683 4.8098 9.1374 6.268 5.727 8.714 8.6552 5.3977 5.4565 8.6552 5.7976 5.9505 4.4687 7.9967 5.9269 6.8795 5.2919 5.2919 5.727 4.6334 3.8102 3.3515 4.1512 5.2566 4.3511 3.5632 8.4553 3.8102 3.5632 5.2566 5.8446 4.163 3.7396 3.281 4.3276 5.6447 6.1151 5.7741 6.7148 6.021 5.9975 2.6342 4.2688 7.9967 4.8215 6.2092 4.7862 5.0097 4.9862 5.5624 4.3041 4.6216 3.5632 4.8803 3.8102 5.3037 5.8093 4.751 3.5632 10.8425 5.386 3.6808 3.8102 6.7384 6.1857 4.8098 6.8795 5.7976 3.6808 6.1857 8.4553 5.5977 6.0445 3.5632 3.8102 10.5368 4.9038 7.6439 6.0681 5.5271 5.3507 3.9866 6.1739 5.68 5.974 3.7867 6.8795 5.8564 5.2566 6.1857 4.8333 4.3746 4.9509 6.021 5.2096 3.3515 3.6808 4.3041 4.7274 4.2218 0.635 5.9269 3.5632 6.268 5.7741 6.4561 5.3507 9.1256 10.0076 12.6065 4.2218 6.2327 3.5632 6.1857 4.8803 5.8329 5.7976 5.0214 4.9038 5.386 4.1747 5.2919 3.5632 6.1151 4.6569 4.7274 5.0097 6.6796 6.7501 6.5502 4.7627 5.4213 5.2566 8.2554 4.7274 4.5863 6.1033 5.7623 5.8564 4.5746 5.7388 5.2919 10.5368 3.6808 4.3041 3.3515 5.2566 12.924 4.7274 5.5389 7.7027 5.5389 5.2566 6.656 4.5746 6.6443 6.0916 4.7627 3.281 3.5632 5.2684 3.281 5.3507 14.6292 5.8211 5.3507 5.2684 4.9862 3.4927 8.6552 6.6678 6.021 3.5632 3.622 3.5632 4.8686 13 2035 6.7526 4.0327 5.57 11.2347 5.641 6.0313 6.9537 7.4504 7.545 3.8316 5.4991 4.8368 9.1888 6.3033 5.7593 8.7631 8.7039 5.4281 5.4873 8.7039 5.8302 5.984 4.4939 8.0417 5.9603 6.9182 5.3217 5.3217 5.7593 4.6594 3.8316 3.3704 4.1746 5.2862 4.3756 3.5833 8.5029 3.8316 3.5833 5.2862 5.8775 4.1864 3.7607 3.2995 4.352 5.6765 6.1495 5.8066 6.7526 6.0549 6.0313 2.649 4.2928 8.0417 4.8487 6.2441 4.8132 5.0379 5.0142 5.5937 4.3283 4.6476 3.5833 4.9078 3.8316 5.3335 5.842 4.7777 3.5833 10.9036 5.4163 3.7015 3.8316 6.7763 6.2205 4.8368 6.9182 5.8302 3.7015 6.2205 8.5029 5.6292 6.0786 3.5833 3.8316 10.5961 4.9314 7.6869 6.1022 5.5582 5.3808 4.009 6.2086 5.712 6.0076 3.808 6.9182 5.8893 5.2862 6.2205 4.8605 4.3993 4.9787 6.0549 5.2389 3.3704 3.7015 4.3283 4.754 4.2455 0.6386 5.9603 3.5833 6.3033 5.8066 6.4925 5.3808 9.177 10.0639 12.6775 4.2455 6.2678 3.5833 6.2205 4.9078 5.8657 5.8302 5.0497 4.9314 5.4163 4.1982 5.3217 3.5833 6.1495 4.6831 4.754 5.0379 6.7172 6.7881 6.5871 4.7895 5.4518 5.2862 8.3018 4.754 4.6121 6.1377 5.7947 5.8893 4.6003 5.7711 5.3217 10.5961 3.7015 4.3283 3.3704 5.2862 12.9968 4.754 5.57 7.746 5.57 5.2862 6.6935 4.6003 6.6817 6.1259 4.7895 3.2995 3.5833 5.298 3.2995 5.3808 14.7115 5.8539 5.3808 5.298 5.0142 3.5123 8.7039 6.7053 6.0549 3.5833 3.6424 3.5833 4.896 14 2036 6.7756 4.0464 5.589 11.2728 5.6601 6.0517 6.9773 7.4757 7.5706 3.8446 5.5178 4.8533 9.22 6.3247 5.7788 8.7928 8.7335 5.4466 5.5059 8.7335 5.85 6.0043 4.5091 8.069 5.9805 6.9417 5.3398 5.3398 5.7788 4.6753 3.8446 3.3818 4.1887 5.3042 4.3905 3.5954 8.5318 3.8446 3.5954 5.3042 5.8975 4.2006 3.7734 3.3107 4.3667 5.6957 6.1704 5.8263 6.7756 6.0755 6.0517 2.658 4.3074 8.069 4.8651 6.2653 4.8295 5.055 5.0312 5.6127 4.343 4.6634 3.5954 4.9244 3.8446 5.3516 5.8619 4.7939 3.5954 10.9406 5.4347 3.7141 3.8446 6.7993 6.2416 4.8533 6.9417 5.85 3.7141 6.2416 8.5318 5.6483 6.0992 3.5954 3.8446 10.6321 4.9482 7.713 6.1229 5.5771 5.3991 4.0226 6.2297 5.7313 6.028 3.8209 6.9417 5.9093 5.3042 6.2416 4.877 4.4142 4.9956 6.0755 5.2567 3.3818 3.7141 4.343 4.7702 4.2599 0.6408 5.9805 3.5954 6.3247 5.8263 6.5145 5.3991 9.2081 10.0981 12.7205 4.2599 6.2891 3.5954 6.2416 4.9244 5.8856 5.85 5.0668 4.9482 5.4347 4.2125 5.3398 3.5954 6.1704 4.699 4.7702 5.055 6.74 6.8112 6.6094 4.8058 5.4703 5.3042 8.33 4.7702 4.6278 6.1585 5.8144 5.9093 4.6159 5.7907 5.3398 10.6321 3.7141 4.343 3.3818 5.3042 13.0409 4.7702 5.589 7.7723 5.589 5.3042 6.7162 4.6159 6.7044 6.1467 4.8058 3.3107 3.5954 5.316 3.3107 5.3991 14.7615 5.8737 5.3991 5.316 5.0312 3.5242 8.7335 6.7281 6.0755 3.5954 3.6548 3.5954 4.9126 15 2037 6.8583 4.0958 5.6572 11.4105 5.7293 6.1256 7.0625 7.567 7.663 3.8916 5.5851 4.9125 9.3326 6.4019 5.8494 8.9002 8.8401 5.5131 5.5731 8.8401 5.9214 6.0776 4.5642 8.1675 6.0536 7.0265 5.405 5.405 5.8494 4.7324 3.8916 3.4231 4.2399 5.3689 4.4441 3.6393 8.6359 3.8916 3.6393 5.3689 5.9695 4.2519 3.8195 3.3511 4.4201 5.7653 6.2457 5.8974 6.8583 6.1497 6.1256 2.6905 4.36 8.1675 4.9245 6.3418 4.8885 5.1167 5.0927 5.6812 4.396 4.7203 3.6393 4.9846 3.8916 5.417 5.9335 4.8525 3.6393 11.0742 5.5011 3.7595 3.8916 6.8823 6.3178 4.9125 7.0265 5.9214 3.7595 6.3178 8.6359 5.7173 6.1737 3.6393 3.8916 10.7619 5.0086 7.8072 6.1977 5.6452 5.465 4.0717 6.3058 5.8013 6.1016 3.8676 7.0265 5.9815 5.3689 6.3178 4.9365 4.4681 5.0567 6.1497 5.3209 3.4231 3.7595 4.396 4.8284 4.312 0.6486 6.0536 3.6393 6.4019 5.8974 6.5941 5.465 9.3206 10.2214 12.8758 4.312 6.3659 3.6393 6.3178 4.9846 5.9575 5.9214 5.1287 5.0086 5.5011 4.2639 5.405 3.6393 6.2457 4.7564 4.8284 5.1167 6.8223 6.8943 6.6902 4.8645 5.5371 5.3689 8.4318 4.8284 4.6843 6.2337 5.8854 5.9815 4.6723 5.8614 5.405 10.7619 3.7595 4.396 3.4231 5.3689 13.2001 4.8284 5.6572 7.8672 5.6572 5.3689 6.7983 4.6723 6.7862 6.2217 4.8645 3.3511 3.6393 5.3809 3.3511 5.465 14.9417 5.9455 5.465 5.3809 5.0927 3.5673 8.8401 6.8103 6.1497 3.6393 3.6994 3.6393 4.9726 16 2038 6.8782 4.1076 5.6736 11.4436 5.7459 6.1434 7.083 7.5889 7.6853 3.9029 5.6013 4.9268 9.3596 6.4204 5.8663 8.926 8.8657 5.529 5.5893 8.8657 5.9386 6.0952 4.5774 8.1912 6.0711 7.0468 5.4206 5.4206 5.8663 4.7461 3.9029 3.4331 4.2522 5.3845 4.457 3.6499 8.661 3.9029 3.6499 5.3845 5.9868 4.2642 3.8306 3.3608 4.4329 5.782 6.2638 5.9145 6.8782 6.1675 6.1434 2.6983 4.3726 8.1912 4.9388 6.3602 4.9027 5.1315 5.1074 5.6977 4.4088 4.734 3.6499 4.999 3.9029 5.4327 5.9506 4.8665 3.6499 11.1063 5.517 3.7704 3.9029 6.9023 6.3361 4.9268 7.0468 5.9386 3.7704 6.3361 8.661 5.7338 6.1916 3.6499 3.9029 10.7931 5.0231 7.8298 6.2157 5.6615 5.4809 4.0835 6.3241 5.8181 6.1193 3.8788 7.0468 5.9988 5.3845 6.3361 4.9508 4.4811 5.0713 6.1675 5.3363 3.4331 3.7704 4.4088 4.8424 4.3245 0.6505 6.0711 3.6499 6.4204 5.9145 6.6132 5.4809 9.3476 10.251 12.9131 4.3245 6.3843 3.6499 6.3361 4.999 5.9747 5.9386 5.1436 5.0231 5.517 4.2763 5.4206 3.6499 6.2638 4.7702 4.8424 5.1315 6.842 6.9143 6.7095 4.8786 5.5531 5.3845 8.4562 4.8424 4.6979 6.2518 5.9025 5.9988 4.6858 5.8784 5.4206 10.7931 3.7704 4.4088 3.4331 5.3845 13.2384 4.8424 5.6736 7.89 5.6736 5.3845 6.818 4.6858 6.8059 6.2397 4.8786 3.3608 3.6499 5.3965 3.3608 5.4809 14.985 5.9627 5.4809 5.3965 5.1074 3.5776 8.8657 6.83 6.1675 3.6499 3.7101 3.6499 4.987 17 2039 6.9216 4.1335 5.7094 11.5157 5.7821 6.1821 7.1276 7.6368 7.7337 3.9275 5.6366 4.9578 9.4187 6.4609 5.9033 8.9823 8.9217 5.5639 5.6245 8.9217 5.9761 6.1336 4.6063 8.2428 6.1094 7.0913 5.4548 5.4548 5.9033 4.776 3.9275 3.4547 4.279 5.4185 4.4851 3.6729 8.7156 3.9275 3.6729 5.4185 6.0245 4.2911 3.8547 3.382 4.4608 5.8185 6.3034 5.9518 6.9216 6.2064 6.1821 2.7153 4.4002 8.2428 4.9699 6.4003 4.9336 5.1639 5.1397 5.7336 4.4366 4.7639 3.6729 5.0306 3.9275 5.4669 5.9882 4.8972 3.6729 11.1763 5.5518 3.7941 3.9275 6.9458 6.3761 4.9578 7.0913 5.9761 3.7941 6.3761 8.7156 5.77 6.2306 3.6729 3.9275 10.8612 5.0548 7.8792 6.2549 5.6973 5.5154 4.1093 6.364 5.8548 6.1579 3.9032 7.0913 6.0367 5.4185 6.3761 4.9821 4.5093 5.1033 6.2064 5.37 3.4547 3.7941 4.4366 4.873 4.3517 0.6546 6.1094 3.6729 6.4609 5.9518 6.6549 5.5154 9.4065 10.3157 12.9946 4.3517 6.4246 3.6729 6.3761 5.0306 6.0124 5.9761 5.176 5.0548 5.5518 4.3032 5.4548 3.6729 6.3034 4.8002 4.873 5.1639 6.8852 6.9579 6.7519 4.9093 5.5882 5.4185 8.5095 4.873 4.7275 6.2912 5.9397 6.0367 4.7154 5.9155 5.4548 10.8612 3.7941 4.4366 3.4547 5.4185 13.3219 4.873 5.7094 7.9398 5.7094 5.4185 6.861 4.7154 6.8488 6.2791 4.9093 3.382 3.6729 5.4306 3.382 5.5154 15.0796 6.0003 5.5154 5.4306 5.1397 3.6002 8.9217 6.8731 6.2064 3.6729 3.7335 3.6729 5.0184 18 2040 6.9721 4.1637 5.751 11.5997 5.8243 6.2272 7.1796 7.6925 7.7901 3.9561 5.6778 4.994 9.4874 6.5081 5.9464 9.0478 8.9867 5.6045 5.6656 8.9867 6.0197 6.1784 4.6399 8.303 6.154 7.143 5.4946 5.4946 5.9464 4.8108 3.9561 3.4799 4.3102 5.458 4.5178 3.6997 8.7792 3.9561 3.6997 5.458 6.0685 4.3224 3.8829 3.4067 4.4934 5.8609 6.3493 5.9952 6.9721 6.2516 6.2272 2.7351 4.4323 8.303 5.0062 6.447 4.9696 5.2016 5.1771 5.7754 4.469 4.7986 3.6997 5.0673 3.9561 5.5068 6.0319 4.9329 3.6997 11.2578 5.5923 3.8218 3.9561 6.9965 6.4226 4.994 7.143 6.0197 3.8218 6.4226 8.7792 5.8121 6.2761 3.6997 3.9561 10.9404 5.0917 7.9367 6.3005 5.7388 5.5557 4.1393 6.4104 5.8976 6.2028 3.9317 7.143 6.0807 5.458 6.4226 5.0184 4.5422 5.1405 6.2516 5.4091 3.4799 3.8218 4.469 4.9085 4.3835 0.6594 6.154 3.6997 6.5081 5.9952 6.7034 5.5557 9.4752 10.3909 13.0894 4.3835 6.4714 3.6997 6.4226 5.0673 6.0563 6.0197 5.2138 5.0917 5.5923 4.3346 5.4946 3.6997 6.3493 4.8353 4.9085 5.2016 6.9354 7.0087 6.8011 4.9452 5.6289 5.458 8.5716 4.9085 4.762 6.3371 5.983 6.0807 4.7498 5.9586 5.4946 10.9404 3.8218 4.469 3.4799 5.458 13.4191 4.9085 5.751 7.9977 5.751 5.458 6.911 4.7498 6.8988 6.3249 4.9452 3.4067 3.6997 5.4702 3.4067 5.5557 15.1896 6.0441 5.5557 5.4702 5.1771 3.6264 8.9867 6.9232 6.2516 3.6997 3.7608 3.6997 5.055 19 2041 7.0086 4.1855 5.7812 11.6605 5.8548 6.2599 7.2172 7.7328 7.831 3.9768 5.7075 5.0202 9.5371 6.5422 5.9775 9.0952 9.0338 5.6339 5.6952 9.0338 6.0512 6.2108 4.6642 8.3465 6.1862 7.1804 5.5234 5.5234 5.9775 4.836 3.9768 3.4982 4.3328 5.4866 4.5415 3.7191 8.8252 3.9768 3.7191 5.4866 6.1003 4.3451 3.9032 3.4245 4.5169 5.8916 6.3826 6.0266 7.0086 6.2844 6.2599 2.7494 4.4555 8.3465 5.0324 6.4808 4.9956 5.2288 5.2043 5.8057 4.4924 4.8238 3.7191 5.0938 3.9768 5.5357 6.0635 4.9588 3.7191 11.3168 5.6216 3.8418 3.9768 7.0331 6.4562 5.0202 7.1804 6.0512 3.8418 6.4562 8.8252 5.8425 6.3089 3.7191 3.9768 10.9977 5.1183 7.9782 6.3335 5.7689 5.5848 4.161 6.444 5.9284 6.2353 3.9523 7.1804 6.1126 5.4866 6.4562 5.0447 4.566 5.1674 6.2844 5.4375 3.4982 3.8418 4.4924 4.9342 4.4064 0.6628 6.1862 3.7191 6.5422 6.0266 6.7385 5.5848 9.5248 10.4454 13.158 4.4064 6.5053 3.7191 6.4562 5.0938 6.088 6.0512 5.2411 5.1183 5.6216 4.3573 5.5234 3.7191 6.3826 4.8606 4.9342 5.2288 6.9718 7.0454 6.8367 4.9711 5.6584 5.4866 8.6165 4.9342 4.7869 6.3703 6.0144 6.1126 4.7747 5.9898 5.5234 10.9977 3.8418 4.4924 3.4982 5.4866 13.4894 4.9342 5.7812 8.0396 5.7812 5.4866 6.9472 4.7747 6.9349 6.358 4.9711 3.4245 3.7191 5.4988 3.4245 5.5848 15.2691 6.0757 5.5848 5.4988 5.2043 3.6454 9.0338 6.9595 6.2844 3.7191 3.7805 3.7191 5.0815 20 2042 6.9859 4.172 5.7625 11.6228 5.8359 6.2396 7.1939 7.7078 7.8056 3.964 5.6891 5.0039 9.5062 6.521 5.9582 9.0658 9.0046 5.6157 5.6768 9.0046 6.0316 6.1907 4.6491 8.3195 6.1662 7.1572 5.5055 5.5055 5.9582 4.8204 3.964 3.4868 4.3188 5.4688 4.5268 3.7071 8.7966 3.964 3.7071 5.4688 6.0806 4.331 3.8906 3.4134 4.5023 5.8726 6.362 6.0072 6.9859 6.2641 6.2396 2.7405 4.4411 8.3195 5.0162 6.4598 4.9795 5.2119 5.1874 5.7869 4.4778 4.8082 3.7071 5.0773 3.964 5.5178 6.0439 4.9428 3.7071 11.2802 5.6034 3.8294 3.964 7.0104 6.4354 5.0039 7.1572 6.0316 3.8294 6.4354 8.7966 5.8236 6.2886 3.7071 3.964 10.9622 5.1018 7.9525 6.313 5.7502 5.5667 4.1475 6.4231 5.9093 6.2151 3.9395 7.1572 6.0928 5.4688 6.4354 5.0284 4.5513 5.1507 6.2641 5.4199 3.4868 3.8294 4.4778 4.9183 4.3922 0.6607 6.1662 3.7071 6.521 6.0072 6.7168 5.5667 9.494 10.4116 13.1154 4.3922 6.4843 3.7071 6.4354 5.0773 6.0683 6.0316 5.2242 5.1018 5.6034 4.3433 5.5055 3.7071 6.362 4.8449 4.9183 5.2119 6.9492 7.0226 6.8146 4.955 5.6401 5.4688 8.5887 4.9183 4.7715 6.3497 5.9949 6.0928 4.7592 5.9705 5.5055 10.9622 3.8294 4.4778 3.4868 5.4688 13.4458 4.9183 5.7625 8.0136 5.7625 5.4688 6.9248 4.7592 6.9125 6.3375 4.955 3.4134 3.7071 5.4811 3.4134 5.5667 15.2198 6.0561 5.5667 5.4811 5.1874 3.6337 9.0046 6.937 6.2641 3.7071 3.7682 3.7071 5.0651 21 2043 7.1456 4.2673 5.8942 11.8884 5.9692 6.3822 7.3583 7.8839 7.984 4.0546 5.8191 5.1183 9.7235 6.67 6.0944 9.273 9.2104 5.744 5.8066 9.2104 6.1695 6.3321 4.7554 8.5096 6.3071 7.3208 5.6314 5.6314 6.0944 4.9306 4.0546 3.5665 4.4175 5.5938 4.6302 3.7918 8.9977 4.0546 3.7918 5.5938 6.2195 4.43 3.9795 3.4914 4.6052 6.0068 6.5073 6.1444 7.1456 6.4072 6.3822 2.8032 4.5426 8.5096 5.1308 6.6075 5.0932 5.331 5.306 5.9192 4.5802 4.918 3.7918 5.1934 4.0546 5.6439 6.182 5.0557 3.7918 11.538 5.7315 3.9169 4.0546 7.1706 6.5824 5.1183 7.3208 6.1695 3.9169 6.5824 8.9977 5.9567 6.4323 3.7918 4.0546 11.2127 5.2184 8.1342 6.4573 5.8816 5.6939 4.2423 6.5699 6.0443 6.3572 4.0295 7.3208 6.232 5.5938 6.5824 5.1433 4.6553 5.2684 6.4072 5.5438 3.5665 3.9169 4.5802 5.0307 4.4926 0.6758 6.3071 3.7918 6.67 6.1444 6.8703 5.6939 9.711 10.6495 13.4151 4.4926 6.6325 3.7918 6.5824 5.1934 6.207 6.1695 5.3435 5.2184 5.7315 4.4425 5.6314 3.7918 6.5073 4.9556 5.0307 5.331 7.108 7.1831 6.9704 5.0682 5.769 5.5938 8.7849 5.0307 4.8805 6.4948 6.1319 6.232 4.868 6.1069 5.6314 11.2127 3.9169 4.5802 3.5665 5.5938 13.753 5.0307 5.8942 8.1967 5.8942 5.5938 7.083 4.868 7.0705 6.4823 5.0682 3.4914 3.7918 5.6063 3.4914 5.6939 15.5676 6.1945 5.6939 5.6063 5.306 3.7167 9.2104 7.0955 6.4072 3.7918 3.8543 3.7918 5.1808 22 2044 7.0553 4.2134 5.8197 11.7383 5.8939 6.3016 7.2654 7.7844 7.8832 4.0034 5.7456 5.0537 9.6007 6.5858 6.0174 9.1559 9.0941 5.6715 5.7332 9.0941 6.0916 6.2522 4.6953 8.4022 6.2275 7.2283 5.5603 5.5603 6.0174 4.8683 4.0034 3.5215 4.3617 5.5232 4.5718 3.7439 8.8841 4.0034 3.7439 5.5232 6.141 4.3741 3.9292 3.4474 4.5471 5.9309 6.4252 6.0669 7.0553 6.3263 6.3016 2.7678 4.4853 8.4022 5.066 6.524 5.0289 5.2637 5.239 5.8444 4.5223 4.856 3.7439 5.1278 4.0034 5.5726 6.1039 4.9919 3.7439 11.3923 5.6591 3.8675 4.0034 7.0801 6.4993 5.0537 7.2283 6.0916 3.8675 6.4993 8.8841 5.8815 6.351 3.7439 4.0034 11.0711 5.1525 8.0315 6.3758 5.8074 5.622 4.1887 6.487 5.968 6.2769 3.9787 7.2283 6.1533 5.5232 6.4993 5.0784 4.5965 5.2019 6.3263 5.4738 3.5215 3.8675 4.5223 4.9672 4.4358 0.6672 6.2275 3.7439 6.5858 6.0669 6.7835 5.622 9.5884 10.5151 13.2458 4.4358 6.5487 3.7439 6.4993 5.1278 6.1286 6.0916 5.2761 5.1525 5.6591 4.3864 5.5603 3.7439 6.4252 4.893 4.9672 5.2637 7.0183 7.0924 6.8824 5.0042 5.6962 5.5232 8.674 4.9672 4.8189 6.4128 6.0545 6.1533 4.8065 6.0298 5.5603 11.0711 3.8675 4.5223 3.5215 5.5232 13.5794 4.9672 5.8197 8.0933 5.8197 5.5232 6.9936 4.8065 6.9812 6.4005 5.0042 3.4474 3.7439 5.5355 3.4474 5.622 15.371 6.1163 5.622 5.5355 5.239 3.6698 9.0941 7.0059 6.3263 3.7439 3.8057 3.7439 5.1154 23 2045 7.1375 4.2625 5.8875 11.875 5.9625 6.375 7.35 7.875 7.975 4.05 5.8125 5.1125 9.7125 6.6625 6.0875 9.2625 9.2 5.7375 5.8 9.2 6.1625 6.325 4.75 8.5 6.3 7.3125 5.625 5.625 6.0875 4.925 4.05 3.5625 4.4125 5.5875 4.625 3.7875 8.9875 4.05 3.7875 5.5875 6.2125 4.425 3.975 3.4875 4.6 6 6.5 6.1375 7.1375 6.4 6.375 2.8 4.5375 8.5 5.125 6.6 5.0875 5.325 5.3 5.9125 4.575 4.9125 3.7875 5.1875 4.05 5.6375 6.175 5.05 3.7875 11.525 5.725 3.9125 4.05 7.1625 6.575 5.1125 7.3125 6.1625 3.9125 6.575 8.9875 5.95 6.425 3.7875 4.05 11.2 5.2125 8.125 6.45 5.875 5.6875 4.2375 6.5625 6.0375 6.35 4.025 7.3125 6.225 5.5875 6.575 5.1375 4.65 5.2625 6.4 5.5375 3.5625 3.9125 4.575 5.025 4.4875 0.675 6.3 3.7875 6.6625 6.1375 6.8625 5.6875 9.7 10.6375 13.4 4.4875 6.625 3.7875 6.575 5.1875 6.2 6.1625 5.3375 5.2125 5.725 4.4375 5.625 3.7875 6.5 4.95 5.025 5.325 7.1 7.175 6.9625 5.0625 5.7625 5.5875 8.775 5.025 4.875 6.4875 6.125 6.225 4.8625 6.1 5.625 11.2 3.9125 4.575 3.5625 5.5875 13.7375 5.025 5.8875 8.1875 5.8875 5.5875 7.075 4.8625 7.0625 6.475 5.0625 3.4875 3.7875 5.6 3.4875 5.6875 15.55 6.1875 5.6875 5.6 5.3 3.7125 9.2 7.0875 6.4 3.7875 3.85 3.7875 5.175 24 2046 7.1734 4.284 5.9171 11.9348 5.9925 6.4071 7.387 7.9146 8.0152 4.0704 5.8418 5.1382 9.7614 6.696 6.1181 9.3091 9.2463 5.7664 5.8292 9.2463 6.1935 6.3568 4.7739 8.5428 6.3317 7.3493 5.6533 5.6533 6.1181 4.9498 4.0704 3.5804 4.4347 5.6156 4.6483 3.8066 9.0327 4.0704 3.8066 5.6156 6.2438 4.4473 3.995 3.5051 4.6232 6.0302 6.5327 6.1684 7.1734 6.4322 6.4071 2.8141 4.5603 8.5428 5.1508 6.6332 5.1131 5.3518 5.3267 5.9423 4.598 4.9372 3.8066 5.2136 4.0704 5.6659 6.2061 5.0754 3.8066 11.583 5.7538 3.9322 4.0704 7.1986 6.6081 5.1382 7.3493 6.1935 3.9322 6.6081 9.0327 5.98 6.4573 3.8066 4.0704 11.2564 5.2387 8.1659 6.4825 5.9046 5.7161 4.2588 6.5955 6.0679 6.382 4.0453 7.3493 6.2563 5.6156 6.6081 5.1634 4.6734 5.289 6.4322 5.5654 3.5804 3.9322 4.598 5.0503 4.5101 0.6784 6.3317 3.8066 6.696 6.1684 6.8971 5.7161 9.7488 10.6911 13.4675 4.5101 6.6584 3.8066 6.6081 5.2136 6.2312 6.1935 5.3644 5.2387 5.7538 4.4598 5.6533 3.8066 6.5327 4.9749 5.0503 5.3518 7.1357 7.2111 6.9976 5.088 5.7915 5.6156 8.8192 5.0503 4.8995 6.5202 6.1558 6.2563 4.887 6.1307 5.6533 11.2564 3.9322 4.598 3.5804 5.6156 13.8067 5.0503 5.9171 8.2287 5.9171 5.6156 7.1106 4.887 7.0981 6.5076 5.088 3.5051 3.8066 5.6282 3.5051 5.7161 15.6283 6.2187 5.7161 5.6282 5.3267 3.7312 9.2463 7.1232 6.4322 3.8066 3.8694 3.8066 5.2011 25 2047 7.3989 4.4186 6.1032 12.31 6.1809 6.6085 7.6192 8.1635 8.2671 4.1984 6.0254 5.2998 10.0683 6.9065 6.3105 9.6018 9.537 5.9477 6.0125 9.537 6.3882 6.5567 4.924 8.8114 6.5308 7.5804 5.831 5.831 6.3105 5.1054 4.1984 3.693 4.5741 5.7922 4.7944 3.9262 9.3167 4.1984 3.9262 5.7922 6.4401 4.5871 4.1206 3.6152 4.7685 6.2198 6.7381 6.3623 7.3989 6.6344 6.6085 2.9026 4.7037 8.8114 5.3127 6.8418 5.2739 5.5201 5.4941 6.1291 4.7426 5.0924 3.9262 5.3775 4.1984 5.844 6.4012 5.235 3.9262 11.9472 5.9347 4.0558 4.1984 7.4249 6.8158 5.2998 7.5804 6.3882 4.0558 6.8158 9.3167 6.1679 6.6603 3.9262 4.1984 11.6103 5.4034 8.4226 6.6863 6.0902 5.8958 4.3927 6.8029 6.2587 6.5826 4.1724 7.5804 6.453 5.7922 6.8158 5.3257 4.8203 5.4553 6.6344 5.7403 3.693 4.0558 4.7426 5.2091 4.6519 0.6997 6.5308 3.9262 6.9065 6.3623 7.1139 5.8958 10.0553 11.0272 13.8908 4.6519 6.8677 3.9262 6.8158 5.3775 6.4271 6.3882 5.533 5.4034 5.9347 4.6 5.831 3.9262 6.7381 5.1313 5.2091 5.5201 7.3601 7.4378 7.2175 5.2479 5.9736 5.7922 9.0964 5.2091 5.0536 6.7251 6.3494 6.453 5.0406 6.3234 5.831 11.6103 4.0558 4.7426 3.693 5.7922 14.2407 5.2091 6.1032 8.4874 6.1032 5.7922 7.3342 5.0406 7.3212 6.7122 5.2479 3.6152 3.9262 5.8051 3.6152 5.8958 16.1196 6.4141 5.8958 5.8051 5.4941 3.8485 9.537 7.3471 6.6344 3.9262 3.991 3.9262 5.3646 26 2048 7.4279 4.4359 6.127 12.3581 6.2051 6.6344 7.649 8.1954 8.2995 4.2148 6.049 5.3205 10.1076 6.9336 6.3352 9.6393 9.5743 5.9709 6.036 9.5743 6.4132 6.5823 4.9433 8.8458 6.5563 7.61 5.8538 5.8538 6.3352 5.1254 4.2148 3.7074 4.592 5.8148 4.8132 3.9416 9.3532 4.2148 3.9416 5.8148 6.4653 4.605 4.1367 3.6294 4.7871 6.2441 6.7644 6.3872 7.4279 6.6604 6.6344 2.9139 4.7221 8.8458 5.3335 6.8685 5.2945 5.5416 5.5156 6.153 4.7611 5.1124 3.9416 5.3986 4.2148 5.8669 6.4262 5.2555 3.9416 11.9939 5.9579 4.0717 4.2148 7.4539 6.8425 5.3205 7.61 6.4132 4.0717 6.8425 9.3532 6.1921 6.6864 3.9416 4.2148 11.6557 5.4246 8.4556 6.7124 6.114 5.9189 4.4099 6.8295 6.2831 6.6083 4.1888 7.61 6.4783 5.8148 6.8425 5.3465 4.8392 5.4766 6.6604 5.7628 3.7074 4.0717 4.7611 5.2294 4.6701 0.7025 6.5563 3.9416 6.9336 6.3872 7.1417 5.9189 10.0946 11.0703 13.9452 4.6701 6.8945 3.9416 6.8425 5.3986 6.4522 6.4132 5.5547 5.4246 5.9579 4.618 5.8538 3.9416 6.7644 5.1514 5.2294 5.5416 7.3889 7.4669 7.2458 5.2685 5.9969 5.8148 9.132 5.2294 5.0733 6.7514 6.3742 6.4783 5.0603 6.3482 5.8538 11.6557 4.0717 4.7611 3.7074 5.8148 14.2964 5.2294 6.127 8.5206 6.127 5.8148 7.3628 5.0603 7.3498 6.7384 5.2685 3.6294 3.9416 5.8278 3.6294 5.9189 16.1826 6.4392 5.9189 5.8278 5.5156 3.8635 9.5743 7.3759 6.6604 3.9416 4.0066 3.9416 5.3855 27 2049 7.4748 4.4639 6.1657 12.4362 6.2443 6.6763 7.6974 8.2472 8.3519 4.2414 6.0872 5.3541 10.1715 6.9774 6.3752 9.7002 9.6348 6.0087 6.0741 9.6348 6.4537 6.6239 4.9745 8.9017 6.5977 7.6581 5.8908 5.8908 6.3752 5.1578 4.2414 3.7309 4.621 5.8516 4.8436 3.9665 9.4122 4.2414 3.9665 5.8516 6.5061 4.6341 4.1629 3.6523 4.8174 6.2836 6.8072 6.4276 7.4748 6.7025 6.6763 2.9323 4.7519 8.9017 5.3672 6.9119 5.3279 5.5767 5.5505 6.1919 4.7912 5.1447 3.9665 5.4327 4.2414 5.9039 6.4668 5.2887 3.9665 12.0697 5.9956 4.0974 4.2414 7.501 6.8857 5.3541 7.6581 6.4537 4.0974 6.8857 9.4122 6.2312 6.7286 3.9665 4.2414 11.7293 5.4588 8.509 6.7548 6.1527 5.9563 4.4378 6.8726 6.3228 6.6501 4.2152 7.6581 6.5192 5.8516 6.8857 5.3803 4.8698 5.5112 6.7025 5.7992 3.7309 4.0974 4.7912 5.2625 4.6996 0.7069 6.5977 3.9665 6.9774 6.4276 7.1868 5.9563 10.1584 11.1402 14.0333 4.6996 6.9381 3.9665 6.8857 5.4327 6.493 6.4537 5.5898 5.4588 5.9956 4.6472 5.8908 3.9665 6.8072 5.1839 5.2625 5.5767 7.4355 7.5141 7.2915 5.3018 6.0348 5.8516 9.1897 5.2625 5.1054 6.7941 6.4145 6.5192 5.0923 6.3883 5.8908 11.7293 4.0974 4.7912 3.7309 5.8516 14.3867 5.2625 6.1657 8.5744 6.1657 5.8516 7.4094 5.0923 7.3963 6.781 5.3018 3.6523 3.9665 5.8647 3.6523 5.9563 16.2849 6.4799 5.9563 5.8647 5.5505 3.888 9.6348 7.4225 6.7025 3.9665 4.032 3.9665 5.4196 28 2050 7.5259 4.4944 6.2079 12.5212 6.2869 6.7219 7.7499 8.3035 8.4089 4.2704 6.1288 5.3907 10.241 7.025 6.4187 9.7665 9.7006 6.0497 6.1156 9.7006 6.4978 6.6692 5.0085 8.9625 6.6428 7.7104 5.9311 5.9311 6.4187 5.193 4.2704 3.7563 4.6526 5.8915 4.8767 3.9936 9.4765 4.2704 3.9936 5.8915 6.5505 4.6658 4.1913 3.6773 4.8503 6.3265 6.8537 6.4715 7.5259 6.7482 6.7219 2.9524 4.7844 8.9625 5.4039 6.9591 5.3643 5.6148 5.5884 6.2342 4.8239 5.1798 3.9936 5.4698 4.2704 5.9443 6.511 5.3248 3.9936 12.1521 6.0365 4.1254 4.2704 7.5522 6.9328 5.3907 7.7104 6.4978 4.1254 6.9328 9.4765 6.2738 6.7746 3.9936 4.2704 11.8094 5.4961 8.5671 6.801 6.1947 5.997 4.4681 6.9196 6.366 6.6955 4.244 7.7104 6.5637 5.8915 6.9328 5.417 4.903 5.5489 6.7482 5.8388 3.7563 4.1254 4.8239 5.2984 4.7317 0.7117 6.6428 3.9936 7.025 6.4715 7.2359 5.997 10.2278 11.2163 14.1291 4.7317 6.9855 3.9936 6.9328 5.4698 6.5374 6.4978 5.6279 5.4961 6.0365 4.679 5.9311 3.9936 6.8537 5.2193 5.2984 5.6148 7.4863 7.5654 7.3414 5.338 6.0761 5.8915 9.2525 5.2984 5.1403 6.8405 6.4583 6.5637 5.1271 6.4319 5.9311 11.8094 4.1254 4.8239 3.7563 5.8915 14.485 5.2984 6.2079 8.633 6.2079 5.8915 7.46 5.1271 7.4468 6.8273 5.338 3.6773 3.9936 5.9047 3.6773 5.997 16.3961 6.5242 5.997 5.9047 5.5884 3.9145 9.7006 7.4732 6.7482 3.9936 4.0595 3.9936 5.4566 29 2051 7.5259 4.4944 6.2079 12.5212 6.2869 6.7219 7.7499 8.3035 8.4089 4.2704 6.1288 5.3907 10.241 7.025 6.4187 9.7665 9.7006 6.0497 6.1156 9.7006 6.4978 6.6692 5.0085 8.9625 6.6428 7.7104 5.9311 5.9311 6.4187 5.193 4.2704 3.7563 4.6526 5.8915 4.8767 3.9936 9.4765 4.2704 3.9936 5.8915 6.5505 4.6658 4.1913 3.6773 4.8503 6.3265 6.8537 6.4715 7.5259 6.7482 6.7219 2.9524 4.7844 8.9625 5.4039 6.9591 5.3643 5.6148 5.5884 6.2342 4.8239 5.1798 3.9936 5.4698 4.2704 5.9443 6.511 5.3248 3.9936 12.1521 6.0365 4.1254 4.2704 7.5522 6.9328 5.3907 7.7104 6.4978 4.1254 6.9328 9.4765 6.2738 6.7746 3.9936 4.2704 11.8094 5.4961 8.5671 6.801 6.1947 5.997 4.4681 6.9196 6.366 6.6955 4.244 7.7104 6.5637 5.8915 6.9328 5.417 4.903 5.5489 6.7482 5.8388 3.7563 4.1254 4.8239 5.2984 4.7317 0.7117 6.6428 3.9936 7.025 6.4715 7.2359 5.997 10.2278 11.2163 14.1291 4.7317 6.9855 3.9936 6.9328 5.4698 6.5374 6.4978 5.6279 5.4961 6.0365 4.679 5.9311 3.9936 6.8537 5.2193 5.2984 5.6148 7.4863 7.5654 7.3414 5.338 6.0761 5.8915 9.2525 5.2984 5.1403 6.8405 6.4583 6.5637 5.1271 6.4319 5.9311 11.8094 4.1254 4.8239 3.7563 5.8915 14.485 5.2984 6.2079 8.633 6.2079 5.8915 7.46 5.1271 7.4468 6.8273 5.338 3.6773 3.9936 5.9047 3.6773 5.997 16.3961 6.5242 5.997 5.9047 5.5884 3.9145 9.7006 7.4732 6.7482 3.9936 4.0595 3.9936 5.4566 30 2052 7.5259 4.4944 6.2079 12.5212 6.2869 6.7219 7.7499 8.3035 8.4089 4.2704 6.1288 5.3907 10.241 7.025 6.4187 9.7665 9.7006 6.0497 6.1156 9.7006 6.4978 6.6692 5.0085 8.9625 6.6428 7.7104 5.9311 5.9311 6.4187 5.193 4.2704 3.7563 4.6526 5.8915 4.8767 3.9936 9.4765 4.2704 3.9936 5.8915 6.5505 4.6658 4.1913 3.6773 4.8503 6.3265 6.8537 6.4715 7.5259 6.7482 6.7219 2.9524 4.7844 8.9625 5.4039 6.9591 5.3643 5.6148 5.5884 6.2342 4.8239 5.1798 3.9936 5.4698 4.2704 5.9443 6.511 5.3248 3.9936 12.1521 6.0365 4.1254 4.2704 7.5522 6.9328 5.3907 7.7104 6.4978 4.1254 6.9328 9.4765 6.2738 6.7746 3.9936 4.2704 11.8094 5.4961 8.5671 6.801 6.1947 5.997 4.4681 6.9196 6.366 6.6955 4.244 7.7104 6.5637 5.8915 6.9328 5.417 4.903 5.5489 6.7482 5.8388 3.7563 4.1254 4.8239 5.2984 4.7317 0.7117 6.6428 3.9936 7.025 6.4715 7.2359 5.997 10.2278 11.2163 14.1291 4.7317 6.9855 3.9936 6.9328 5.4698 6.5374 6.4978 5.6279 5.4961 6.0365 4.679 5.9311 3.9936 6.8537 5.2193 5.2984 5.6148 7.4863 7.5654 7.3414 5.338 6.0761 5.8915 9.2525 5.2984 5.1403 6.8405 6.4583 6.5637 5.1271 6.4319 5.9311 11.8094 4.1254 4.8239 3.7563 5.8915 14.485 5.2984 6.2079 8.633 6.2079 5.8915 7.46 5.1271 7.4468 6.8273 5.338 3.6773 3.9936 5.9047 3.6773 5.997 16.3961 6.5242 5.997 5.9047 5.5884 3.9145 9.7006 7.4732 6.7482 3.9936 4.0595 3.9936 5.4566 31 2053 7.5259 4.4944 6.2079 12.5212 6.2869 6.7219 7.7499 8.3035 8.4089 4.2704 6.1288 5.3907 10.241 7.025 6.4187 9.7665 9.7006 6.0497 6.1156 9.7006 6.4978 6.6692 5.0085 8.9625 6.6428 7.7104 5.9311 5.9311 6.4187 5.193 4.2704 3.7563 4.6526 5.8915 4.8767 3.9936 9.4765 4.2704 3.9936 5.8915 6.5505 4.6658 4.1913 3.6773 4.8503 6.3265 6.8537 6.4715 7.5259 6.7482 6.7219 2.9524 4.7844 8.9625 5.4039 6.9591 5.3643 5.6148 5.5884 6.2342 4.8239 5.1798 3.9936 5.4698 4.2704 5.9443 6.511 5.3248 3.9936 12.1521 6.0365 4.1254 4.2704 7.5522 6.9328 5.3907 7.7104 6.4978 4.1254 6.9328 9.4765 6.2738 6.7746 3.9936 4.2704 11.8094 5.4961 8.5671 6.801 6.1947 5.997 4.4681 6.9196 6.366 6.6955 4.244 7.7104 6.5637 5.8915 6.9328 5.417 4.903 5.5489 6.7482 5.8388 3.7563 4.1254 4.8239 5.2984 4.7317 0.7117 6.6428 3.9936 7.025 6.4715 7.2359 5.997 10.2278 11.2163 14.1291 4.7317 6.9855 3.9936 6.9328 5.4698 6.5374 6.4978 5.6279 5.4961 6.0365 4.679 5.9311 3.9936 6.8537 5.2193 5.2984 5.6148 7.4863 7.5654 7.3414 5.338 6.0761 5.8915 9.2525 5.2984 5.1403 6.8405 6.4583 6.5637 5.1271 6.4319 5.9311 11.8094 4.1254 4.8239 3.7563 5.8915 14.485 5.2984 6.2079 8.633 6.2079 5.8915 7.46 5.1271 7.4468 6.8273 5.338 3.6773 3.9936 5.9047 3.6773 5.997 16.3961 6.5242 5.997 5.9047 5.5884 3.9145 9.7006 7.4732 6.7482 3.9936 4.0595 3.9936 5.4566 32 2054 7.5259 4.4944 6.2079 12.5212 6.2869 6.7219 7.7499 8.3035 8.4089 4.2704 6.1288 5.3907 10.241 7.025 6.4187 9.7665 9.7006 6.0497 6.1156 9.7006 6.4978 6.6692 5.0085 8.9625 6.6428 7.7104 5.9311 5.9311 6.4187 5.193 4.2704 3.7563 4.6526 5.8915 4.8767 3.9936 9.4765 4.2704 3.9936 5.8915 6.5505 4.6658 4.1913 3.6773 4.8503 6.3265 6.8537 6.4715 7.5259 6.7482 6.7219 2.9524 4.7844 8.9625 5.4039 6.9591 5.3643 5.6148 5.5884 6.2342 4.8239 5.1798 3.9936 5.4698 4.2704 5.9443 6.511 5.3248 3.9936 12.1521 6.0365 4.1254 4.2704 7.5522 6.9328 5.3907 7.7104 6.4978 4.1254 6.9328 9.4765 6.2738 6.7746 3.9936 4.2704 11.8094 5.4961 8.5671 6.801 6.1947 5.997 4.4681 6.9196 6.366 6.6955 4.244 7.7104 6.5637 5.8915 6.9328 5.417 4.903 5.5489 6.7482 5.8388 3.7563 4.1254 4.8239 5.2984 4.7317 0.7117 6.6428 3.9936 7.025 6.4715 7.2359 5.997 10.2278 11.2163 14.1291 4.7317 6.9855 3.9936 6.9328 5.4698 6.5374 6.4978 5.6279 5.4961 6.0365 4.679 5.9311 3.9936 6.8537 5.2193 5.2984 5.6148 7.4863 7.5654 7.3414 5.338 6.0761 5.8915 9.2525 5.2984 5.1403 6.8405 6.4583 6.5637 5.1271 6.4319 5.9311 11.8094 4.1254 4.8239 3.7563 5.8915 14.485 5.2984 6.2079 8.633 6.2079 5.8915 7.46 5.1271 7.4468 6.8273 5.338 3.6773 3.9936 5.9047 3.6773 5.997 16.3961 6.5242 5.997 5.9047 5.5884 3.9145 9.7006 7.4732 6.7482 3.9936 4.0595 3.9936 5.4566 33 2055 7.5259 4.4944 6.2079 12.5212 6.2869 6.7219 7.7499 8.3035 8.4089 4.2704 6.1288 5.3907 10.241 7.025 6.4187 9.7665 9.7006 6.0497 6.1156 9.7006 6.4978 6.6692 5.0085 8.9625 6.6428 7.7104 5.9311 5.9311 6.4187 5.193 4.2704 3.7563 4.6526 5.8915 4.8767 3.9936 9.4765 4.2704 3.9936 5.8915 6.5505 4.6658 4.1913 3.6773 4.8503 6.3265 6.8537 6.4715 7.5259 6.7482 6.7219 2.9524 4.7844 8.9625 5.4039 6.9591 5.3643 5.6148 5.5884 6.2342 4.8239 5.1798 3.9936 5.4698 4.2704 5.9443 6.511 5.3248 3.9936 12.1521 6.0365 4.1254 4.2704 7.5522 6.9328 5.3907 7.7104 6.4978 4.1254 6.9328 9.4765 6.2738 6.7746 3.9936 4.2704 11.8094 5.4961 8.5671 6.801 6.1947 5.997 4.4681 6.9196 6.366 6.6955 4.244 7.7104 6.5637 5.8915 6.9328 5.417 4.903 5.5489 6.7482 5.8388 3.7563 4.1254 4.8239 5.2984 4.7317 0.7117 6.6428 3.9936 7.025 6.4715 7.2359 5.997 10.2278 11.2163 14.1291 4.7317 6.9855 3.9936 6.9328 5.4698 6.5374 6.4978 5.6279 5.4961 6.0365 4.679 5.9311 3.9936 6.8537 5.2193 5.2984 5.6148 7.4863 7.5654 7.3414 5.338 6.0761 5.8915 9.2525 5.2984 5.1403 6.8405 6.4583 6.5637 5.1271 6.4319 5.9311 11.8094 4.1254 4.8239 3.7563 5.8915 14.485 5.2984 6.2079 8.633 6.2079 5.8915 7.46 5.1271 7.4468 6.8273 5.338 3.6773 3.9936 5.9047 3.6773 5.997 16.3961 6.5242 5.997 5.9047 5.5884 3.9145 9.7006 7.4732 6.7482 3.9936 4.0595 3.9936 5.4566 34 2056 7.5259 4.4944 6.2079 12.5212 6.2869 6.7219 7.7499 8.3035 8.4089 4.2704 6.1288 5.3907 10.241 7.025 6.4187 9.7665 9.7006 6.0497 6.1156 9.7006 6.4978 6.6692 5.0085 8.9625 6.6428 7.7104 5.9311 5.9311 6.4187 5.193 4.2704 3.7563 4.6526 5.8915 4.8767 3.9936 9.4765 4.2704 3.9936 5.8915 6.5505 4.6658 4.1913 3.6773 4.8503 6.3265 6.8537 6.4715 7.5259 6.7482 6.7219 2.9524 4.7844 8.9625 5.4039 6.9591 5.3643 5.6148 5.5884 6.2342 4.8239 5.1798 3.9936 5.4698 4.2704 5.9443 6.511 5.3248 3.9936 12.1521 6.0365 4.1254 4.2704 7.5522 6.9328 5.3907 7.7104 6.4978 4.1254 6.9328 9.4765 6.2738 6.7746 3.9936 4.2704 11.8094 5.4961 8.5671 6.801 6.1947 5.997 4.4681 6.9196 6.366 6.6955 4.244 7.7104 6.5637 5.8915 6.9328 5.417 4.903 5.5489 6.7482 5.8388 3.7563 4.1254 4.8239 5.2984 4.7317 0.7117 6.6428 3.9936 7.025 6.4715 7.2359 5.997 10.2278 11.2163 14.1291 4.7317 6.9855 3.9936 6.9328 5.4698 6.5374 6.4978 5.6279 5.4961 6.0365 4.679 5.9311 3.9936 6.8537 5.2193 5.2984 5.6148 7.4863 7.5654 7.3414 5.338 6.0761 5.8915 9.2525 5.2984 5.1403 6.8405 6.4583 6.5637 5.1271 6.4319 5.9311 11.8094 4.1254 4.8239 3.7563 5.8915 14.485 5.2984 6.2079 8.633 6.2079 5.8915 7.46 5.1271 7.4468 6.8273 5.338 3.6773 3.9936 5.9047 3.6773 5.997 16.3961 6.5242 5.997 5.9047 5.5884 3.9145 9.7006 7.4732 6.7482 3.9936 4.0595 3.9936 5.4566 35 2057 7.5259 4.4944 6.2079 12.5212 6.2869 6.7219 7.7499 8.3035 8.4089 4.2704 6.1288 5.3907 10.241 7.025 6.4187 9.7665 9.7006 6.0497 6.1156 9.7006 6.4978 6.6692 5.0085 8.9625 6.6428 7.7104 5.9311 5.9311 6.4187 5.193 4.2704 3.7563 4.6526 5.8915 4.8767 3.9936 9.4765 4.2704 3.9936 5.8915 6.5505 4.6658 4.1913 3.6773 4.8503 6.3265 6.8537 6.4715 7.5259 6.7482 6.7219 2.9524 4.7844 8.9625 5.4039 6.9591 5.3643 5.6148 5.5884 6.2342 4.8239 5.1798 3.9936 5.4698 4.2704 5.9443 6.511 5.3248 3.9936 12.1521 6.0365 4.1254 4.2704 7.5522 6.9328 5.3907 7.7104 6.4978 4.1254 6.9328 9.4765 6.2738 6.7746 3.9936 4.2704 11.8094 5.4961 8.5671 6.801 6.1947 5.997 4.4681 6.9196 6.366 6.6955 4.244 7.7104 6.5637 5.8915 6.9328 5.417 4.903 5.5489 6.7482 5.8388 3.7563 4.1254 4.8239 5.2984 4.7317 0.7117 6.6428 3.9936 7.025 6.4715 7.2359 5.997 10.2278 11.2163 14.1291 4.7317 6.9855 3.9936 6.9328 5.4698 6.5374 6.4978 5.6279 5.4961 6.0365 4.679 5.9311 3.9936 6.8537 5.2193 5.2984 5.6148 7.4863 7.5654 7.3414 5.338 6.0761 5.8915 9.2525 5.2984 5.1403 6.8405 6.4583 6.5637 5.1271 6.4319 5.9311 11.8094 4.1254 4.8239 3.7563 5.8915 14.485 5.2984 6.2079 8.633 6.2079 5.8915 7.46 5.1271 7.4468 6.8273 5.338 3.6773 3.9936 5.9047 3.6773 5.997 16.3961 6.5242 5.997 5.9047 5.5884 3.9145 9.7006 7.4732 6.7482 3.9936 4.0595 3.9936 5.4566 36 2058 7.5259 4.4944 6.2079 12.5212 6.2869 6.7219 7.7499 8.3035 8.4089 4.2704 6.1288 5.3907 10.241 7.025 6.4187 9.7665 9.7006 6.0497 6.1156 9.7006 6.4978 6.6692 5.0085 8.9625 6.6428 7.7104 5.9311 5.9311 6.4187 5.193 4.2704 3.7563 4.6526 5.8915 4.8767 3.9936 9.4765 4.2704 3.9936 5.8915 6.5505 4.6658 4.1913 3.6773 4.8503 6.3265 6.8537 6.4715 7.5259 6.7482 6.7219 2.9524 4.7844 8.9625 5.4039 6.9591 5.3643 5.6148 5.5884 6.2342 4.8239 5.1798 3.9936 5.4698 4.2704 5.9443 6.511 5.3248 3.9936 12.1521 6.0365 4.1254 4.2704 7.5522 6.9328 5.3907 7.7104 6.4978 4.1254 6.9328 9.4765 6.2738 6.7746 3.9936 4.2704 11.8094 5.4961 8.5671 6.801 6.1947 5.997 4.4681 6.9196 6.366 6.6955 4.244 7.7104 6.5637 5.8915 6.9328 5.417 4.903 5.5489 6.7482 5.8388 3.7563 4.1254 4.8239 5.2984 4.7317 0.7117 6.6428 3.9936 7.025 6.4715 7.2359 5.997 10.2278 11.2163 14.1291 4.7317 6.9855 3.9936 6.9328 5.4698 6.5374 6.4978 5.6279 5.4961 6.0365 4.679 5.9311 3.9936 6.8537 5.2193 5.2984 5.6148 7.4863 7.5654 7.3414 5.338 6.0761 5.8915 9.2525 5.2984 5.1403 6.8405 6.4583 6.5637 5.1271 6.4319 5.9311 11.8094 4.1254 4.8239 3.7563 5.8915 14.485 5.2984 6.2079 8.633 6.2079 5.8915 7.46 5.1271 7.4468 6.8273 5.338 3.6773 3.9936 5.9047 3.6773 5.997 16.3961 6.5242 5.997 5.9047 5.5884 3.9145 9.7006 7.4732 6.7482 3.9936 4.0595 3.9936 5.4566 37 2059 7.5259 4.4944 6.2079 12.5212 6.2869 6.7219 7.7499 8.3035 8.4089 4.2704 6.1288 5.3907 10.241 7.025 6.4187 9.7665 9.7006 6.0497 6.1156 9.7006 6.4978 6.6692 5.0085 8.9625 6.6428 7.7104 5.9311 5.9311 6.4187 5.193 4.2704 3.7563 4.6526 5.8915 4.8767 3.9936 9.4765 4.2704 3.9936 5.8915 6.5505 4.6658 4.1913 3.6773 4.8503 6.3265 6.8537 6.4715 7.5259 6.7482 6.7219 2.9524 4.7844 8.9625 5.4039 6.9591 5.3643 5.6148 5.5884 6.2342 4.8239 5.1798 3.9936 5.4698 4.2704 5.9443 6.511 5.3248 3.9936 12.1521 6.0365 4.1254 4.2704 7.5522 6.9328 5.3907 7.7104 6.4978 4.1254 6.9328 9.4765 6.2738 6.7746 3.9936 4.2704 11.8094 5.4961 8.5671 6.801 6.1947 5.997 4.4681 6.9196 6.366 6.6955 4.244 7.7104 6.5637 5.8915 6.9328 5.417 4.903 5.5489 6.7482 5.8388 3.7563 4.1254 4.8239 5.2984 4.7317 0.7117 6.6428 3.9936 7.025 6.4715 7.2359 5.997 10.2278 11.2163 14.1291 4.7317 6.9855 3.9936 6.9328 5.4698 6.5374 6.4978 5.6279 5.4961 6.0365 4.679 5.9311 3.9936 6.8537 5.2193 5.2984 5.6148 7.4863 7.5654 7.3414 5.338 6.0761 5.8915 9.2525 5.2984 5.1403 6.8405 6.4583 6.5637 5.1271 6.4319 5.9311 11.8094 4.1254 4.8239 3.7563 5.8915 14.485 5.2984 6.2079 8.633 6.2079 5.8915 7.46 5.1271 7.4468 6.8273 5.338 3.6773 3.9936 5.9047 3.6773 5.997 16.3961 6.5242 5.997 5.9047 5.5884 3.9145 9.7006 7.4732 6.7482 3.9936 4.0595 3.9936 5.4566 38 2060 7.5259 4.4944 6.2079 12.5212 6.2869 6.7219 7.7499 8.3035 8.4089 4.2704 6.1288 5.3907 10.241 7.025 6.4187 9.7665 9.7006 6.0497 6.1156 9.7006 6.4978 6.6692 5.0085 8.9625 6.6428 7.7104 5.9311 5.9311 6.4187 5.193 4.2704 3.7563 4.6526 5.8915 4.8767 3.9936 9.4765 4.2704 3.9936 5.8915 6.5505 4.6658 4.1913 3.6773 4.8503 6.3265 6.8537 6.4715 7.5259 6.7482 6.7219 2.9524 4.7844 8.9625 5.4039 6.9591 5.3643 5.6148 5.5884 6.2342 4.8239 5.1798 3.9936 5.4698 4.2704 5.9443 6.511 5.3248 3.9936 12.1521 6.0365 4.1254 4.2704 7.5522 6.9328 5.3907 7.7104 6.4978 4.1254 6.9328 9.4765 6.2738 6.7746 3.9936 4.2704 11.8094 5.4961 8.5671 6.801 6.1947 5.997 4.4681 6.9196 6.366 6.6955 4.244 7.7104 6.5637 5.8915 6.9328 5.417 4.903 5.5489 6.7482 5.8388 3.7563 4.1254 4.8239 5.2984 4.7317 0.7117 6.6428 3.9936 7.025 6.4715 7.2359 5.997 10.2278 11.2163 14.1291 4.7317 6.9855 3.9936 6.9328 5.4698 6.5374 6.4978 5.6279 5.4961 6.0365 4.679 5.9311 3.9936 6.8537 5.2193 5.2984 5.6148 7.4863 7.5654 7.3414 5.338 6.0761 5.8915 9.2525 5.2984 5.1403 6.8405 6.4583 6.5637 5.1271 6.4319 5.9311 11.8094 4.1254 4.8239 3.7563 5.8915 14.485 5.2984 6.2079 8.633 6.2079 5.8915 7.46 5.1271 7.4468 6.8273 5.338 3.6773 3.9936 5.9047 3.6773 5.997 16.3961 6.5242 5.997 5.9047 5.5884 3.9145 9.7006 7.4732 6.7482 3.9936 4.0595 3.9936 5.4566 39 2061 7.5259 4.4944 6.2079 12.5212 6.2869 6.7219 7.7499 8.3035 8.4089 4.2704 6.1288 5.3907 10.241 7.025 6.4187 9.7665 9.7006 6.0497 6.1156 9.7006 6.4978 6.6692 5.0085 8.9625 6.6428 7.7104 5.9311 5.9311 6.4187 5.193 4.2704 3.7563 4.6526 5.8915 4.8767 3.9936 9.4765 4.2704 3.9936 5.8915 6.5505 4.6658 4.1913 3.6773 4.8503 6.3265 6.8537 6.4715 7.5259 6.7482 6.7219 2.9524 4.7844 8.9625 5.4039 6.9591 5.3643 5.6148 5.5884 6.2342 4.8239 5.1798 3.9936 5.4698 4.2704 5.9443 6.511 5.3248 3.9936 12.1521 6.0365 4.1254 4.2704 7.5522 6.9328 5.3907 7.7104 6.4978 4.1254 6.9328 9.4765 6.2738 6.7746 3.9936 4.2704 11.8094 5.4961 8.5671 6.801 6.1947 5.997 4.4681 6.9196 6.366 6.6955 4.244 7.7104 6.5637 5.8915 6.9328 5.417 4.903 5.5489 6.7482 5.8388 3.7563 4.1254 4.8239 5.2984 4.7317 0.7117 6.6428 3.9936 7.025 6.4715 7.2359 5.997 10.2278 11.2163 14.1291 4.7317 6.9855 3.9936 6.9328 5.4698 6.5374 6.4978 5.6279 5.4961 6.0365 4.679 5.9311 3.9936 6.8537 5.2193 5.2984 5.6148 7.4863 7.5654 7.3414 5.338 6.0761 5.8915 9.2525 5.2984 5.1403 6.8405 6.4583 6.5637 5.1271 6.4319 5.9311 11.8094 4.1254 4.8239 3.7563 5.8915 14.485 5.2984 6.2079 8.633 6.2079 5.8915 7.46 5.1271 7.4468 6.8273 5.338 3.6773 3.9936 5.9047 3.6773 5.997 16.3961 6.5242 5.997 5.9047 5.5884 3.9145 9.7006 7.4732 6.7482 3.9936 4.0595 3.9936 5.4566 40 2062 7.5259 4.4944 6.2079 12.5212 6.2869 6.7219 7.7499 8.3035 8.4089 4.2704 6.1288 5.3907 10.241 7.025 6.4187 9.7665 9.7006 6.0497 6.1156 9.7006 6.4978 6.6692 5.0085 8.9625 6.6428 7.7104 5.9311 5.9311 6.4187 5.193 4.2704 3.7563 4.6526 5.8915 4.8767 3.9936 9.4765 4.2704 3.9936 5.8915 6.5505 4.6658 4.1913 3.6773 4.8503 6.3265 6.8537 6.4715 7.5259 6.7482 6.7219 2.9524 4.7844 8.9625 5.4039 6.9591 5.3643 5.6148 5.5884 6.2342 4.8239 5.1798 3.9936 5.4698 4.2704 5.9443 6.511 5.3248 3.9936 12.1521 6.0365 4.1254 4.2704 7.5522 6.9328 5.3907 7.7104 6.4978 4.1254 6.9328 9.4765 6.2738 6.7746 3.9936 4.2704 11.8094 5.4961 8.5671 6.801 6.1947 5.997 4.4681 6.9196 6.366 6.6955 4.244 7.7104 6.5637 5.8915 6.9328 5.417 4.903 5.5489 6.7482 5.8388 3.7563 4.1254 4.8239 5.2984 4.7317 0.7117 6.6428 3.9936 7.025 6.4715 7.2359 5.997 10.2278 11.2163 14.1291 4.7317 6.9855 3.9936 6.9328 5.4698 6.5374 6.4978 5.6279 5.4961 6.0365 4.679 5.9311 3.9936 6.8537 5.2193 5.2984 5.6148 7.4863 7.5654 7.3414 5.338 6.0761 5.8915 9.2525 5.2984 5.1403 6.8405 6.4583 6.5637 5.1271 6.4319 5.9311 11.8094 4.1254 4.8239 3.7563 5.8915 14.485 5.2984 6.2079 8.633 6.2079 5.8915 7.46 5.1271 7.4468 6.8273 5.338 3.6773 3.9936 5.9047 3.6773 5.997 16.3961 6.5242 5.997 5.9047 5.5884 3.9145 9.7006 7.4732 6.7482 3.9936 4.0595 3.9936 5.4566 41 2063 7.5259 4.4944 6.2079 12.5212 6.2869 6.7219 7.7499 8.3035 8.4089 4.2704 6.1288 5.3907 10.241 7.025 6.4187 9.7665 9.7006 6.0497 6.1156 9.7006 6.4978 6.6692 5.0085 8.9625 6.6428 7.7104 5.9311 5.9311 6.4187 5.193 4.2704 3.7563 4.6526 5.8915 4.8767 3.9936 9.4765 4.2704 3.9936 5.8915 6.5505 4.6658 4.1913 3.6773 4.8503 6.3265 6.8537 6.4715 7.5259 6.7482 6.7219 2.9524 4.7844 8.9625 5.4039 6.9591 5.3643 5.6148 5.5884 6.2342 4.8239 5.1798 3.9936 5.4698 4.2704 5.9443 6.511 5.3248 3.9936 12.1521 6.0365 4.1254 4.2704 7.5522 6.9328 5.3907 7.7104 6.4978 4.1254 6.9328 9.4765 6.2738 6.7746 3.9936 4.2704 11.8094 5.4961 8.5671 6.801 6.1947 5.997 4.4681 6.9196 6.366 6.6955 4.244 7.7104 6.5637 5.8915 6.9328 5.417 4.903 5.5489 6.7482 5.8388 3.7563 4.1254 4.8239 5.2984 4.7317 0.7117 6.6428 3.9936 7.025 6.4715 7.2359 5.997 10.2278 11.2163 14.1291 4.7317 6.9855 3.9936 6.9328 5.4698 6.5374 6.4978 5.6279 5.4961 6.0365 4.679 5.9311 3.9936 6.8537 5.2193 5.2984 5.6148 7.4863 7.5654 7.3414 5.338 6.0761 5.8915 9.2525 5.2984 5.1403 6.8405 6.4583 6.5637 5.1271 6.4319 5.9311 11.8094 4.1254 4.8239 3.7563 5.8915 14.485 5.2984 6.2079 8.633 6.2079 5.8915 7.46 5.1271 7.4468 6.8273 5.338 3.6773 3.9936 5.9047 3.6773 5.997 16.3961 6.5242 5.997 5.9047 5.5884 3.9145 9.7006 7.4732 6.7482 3.9936 4.0595 3.9936 5.4566 42 2064 7.5259 4.4944 6.2079 12.5212 6.2869 6.7219 7.7499 8.3035 8.4089 4.2704 6.1288 5.3907 10.241 7.025 6.4187 9.7665 9.7006 6.0497 6.1156 9.7006 6.4978 6.6692 5.0085 8.9625 6.6428 7.7104 5.9311 5.9311 6.4187 5.193 4.2704 3.7563 4.6526 5.8915 4.8767 3.9936 9.4765 4.2704 3.9936 5.8915 6.5505 4.6658 4.1913 3.6773 4.8503 6.3265 6.8537 6.4715 7.5259 6.7482 6.7219 2.9524 4.7844 8.9625 5.4039 6.9591 5.3643 5.6148 5.5884 6.2342 4.8239 5.1798 3.9936 5.4698 4.2704 5.9443 6.511 5.3248 3.9936 12.1521 6.0365 4.1254 4.2704 7.5522 6.9328 5.3907 7.7104 6.4978 4.1254 6.9328 9.4765 6.2738 6.7746 3.9936 4.2704 11.8094 5.4961 8.5671 6.801 6.1947 5.997 4.4681 6.9196 6.366 6.6955 4.244 7.7104 6.5637 5.8915 6.9328 5.417 4.903 5.5489 6.7482 5.8388 3.7563 4.1254 4.8239 5.2984 4.7317 0.7117 6.6428 3.9936 7.025 6.4715 7.2359 5.997 10.2278 11.2163 14.1291 4.7317 6.9855 3.9936 6.9328 5.4698 6.5374 6.4978 5.6279 5.4961 6.0365 4.679 5.9311 3.9936 6.8537 5.2193 5.2984 5.6148 7.4863 7.5654 7.3414 5.338 6.0761 5.8915 9.2525 5.2984 5.1403 6.8405 6.4583 6.5637 5.1271 6.4319 5.9311 11.8094 4.1254 4.8239 3.7563 5.8915 14.485 5.2984 6.2079 8.633 6.2079 5.8915 7.46 5.1271 7.4468 6.8273 5.338 3.6773 3.9936 5.9047 3.6773 5.997 16.3961 6.5242 5.997 5.9047 5.5884 3.9145 9.7006 7.4732 6.7482 3.9936 4.0595 3.9936 5.4566 43 2065 7.5259 4.4944 6.2079 12.5212 6.2869 6.7219 7.7499 8.3035 8.4089 4.2704 6.1288 5.3907 10.241 7.025 6.4187 9.7665 9.7006 6.0497 6.1156 9.7006 6.4978 6.6692 5.0085 8.9625 6.6428 7.7104 5.9311 5.9311 6.4187 5.193 4.2704 3.7563 4.6526 5.8915 4.8767 3.9936 9.4765 4.2704 3.9936 5.8915 6.5505 4.6658 4.1913 3.6773 4.8503 6.3265 6.8537 6.4715 7.5259 6.7482 6.7219 2.9524 4.7844 8.9625 5.4039 6.9591 5.3643 5.6148 5.5884 6.2342 4.8239 5.1798 3.9936 5.4698 4.2704 5.9443 6.511 5.3248 3.9936 12.1521 6.0365 4.1254 4.2704 7.5522 6.9328 5.3907 7.7104 6.4978 4.1254 6.9328 9.4765 6.2738 6.7746 3.9936 4.2704 11.8094 5.4961 8.5671 6.801 6.1947 5.997 4.4681 6.9196 6.366 6.6955 4.244 7.7104 6.5637 5.8915 6.9328 5.417 4.903 5.5489 6.7482 5.8388 3.7563 4.1254 4.8239 5.2984 4.7317 0.7117 6.6428 3.9936 7.025 6.4715 7.2359 5.997 10.2278 11.2163 14.1291 4.7317 6.9855 3.9936 6.9328 5.4698 6.5374 6.4978 5.6279 5.4961 6.0365 4.679 5.9311 3.9936 6.8537 5.2193 5.2984 5.6148 7.4863 7.5654 7.3414 5.338 6.0761 5.8915 9.2525 5.2984 5.1403 6.8405 6.4583 6.5637 5.1271 6.4319 5.9311 11.8094 4.1254 4.8239 3.7563 5.8915 14.485 5.2984 6.2079 8.633 6.2079 5.8915 7.46 5.1271 7.4468 6.8273 5.338 3.6773 3.9936 5.9047 3.6773 5.997 16.3961 6.5242 5.997 5.9047 5.5884 3.9145 9.7006 7.4732 6.7482 3.9936 4.0595 3.9936 5.4566 44 2066 7.5259 4.4944 6.2079 12.5212 6.2869 6.7219 7.7499 8.3035 8.4089 4.2704 6.1288 5.3907 10.241 7.025 6.4187 9.7665 9.7006 6.0497 6.1156 9.7006 6.4978 6.6692 5.0085 8.9625 6.6428 7.7104 5.9311 5.9311 6.4187 5.193 4.2704 3.7563 4.6526 5.8915 4.8767 3.9936 9.4765 4.2704 3.9936 5.8915 6.5505 4.6658 4.1913 3.6773 4.8503 6.3265 6.8537 6.4715 7.5259 6.7482 6.7219 2.9524 4.7844 8.9625 5.4039 6.9591 5.3643 5.6148 5.5884 6.2342 4.8239 5.1798 3.9936 5.4698 4.2704 5.9443 6.511 5.3248 3.9936 12.1521 6.0365 4.1254 4.2704 7.5522 6.9328 5.3907 7.7104 6.4978 4.1254 6.9328 9.4765 6.2738 6.7746 3.9936 4.2704 11.8094 5.4961 8.5671 6.801 6.1947 5.997 4.4681 6.9196 6.366 6.6955 4.244 7.7104 6.5637 5.8915 6.9328 5.417 4.903 5.5489 6.7482 5.8388 3.7563 4.1254 4.8239 5.2984 4.7317 0.7117 6.6428 3.9936 7.025 6.4715 7.2359 5.997 10.2278 11.2163 14.1291 4.7317 6.9855 3.9936 6.9328 5.4698 6.5374 6.4978 5.6279 5.4961 6.0365 4.679 5.9311 3.9936 6.8537 5.2193 5.2984 5.6148 7.4863 7.5654 7.3414 5.338 6.0761 5.8915 9.2525 5.2984 5.1403 6.8405 6.4583 6.5637 5.1271 6.4319 5.9311 11.8094 4.1254 4.8239 3.7563 5.8915 14.485 5.2984 6.2079 8.633 6.2079 5.8915 7.46 5.1271 7.4468 6.8273 5.338 3.6773 3.9936 5.9047 3.6773 5.997 16.3961 6.5242 5.997 5.9047 5.5884 3.9145 9.7006 7.4732 6.7482 3.9936 4.0595 3.9936 5.4566 45 2067 7.5259 4.4944 6.2079 12.5212 6.2869 6.7219 7.7499 8.3035 8.4089 4.2704 6.1288 5.3907 10.241 7.025 6.4187 9.7665 9.7006 6.0497 6.1156 9.7006 6.4978 6.6692 5.0085 8.9625 6.6428 7.7104 5.9311 5.9311 6.4187 5.193 4.2704 3.7563 4.6526 5.8915 4.8767 3.9936 9.4765 4.2704 3.9936 5.8915 6.5505 4.6658 4.1913 3.6773 4.8503 6.3265 6.8537 6.4715 7.5259 6.7482 6.7219 2.9524 4.7844 8.9625 5.4039 6.9591 5.3643 5.6148 5.5884 6.2342 4.8239 5.1798 3.9936 5.4698 4.2704 5.9443 6.511 5.3248 3.9936 12.1521 6.0365 4.1254 4.2704 7.5522 6.9328 5.3907 7.7104 6.4978 4.1254 6.9328 9.4765 6.2738 6.7746 3.9936 4.2704 11.8094 5.4961 8.5671 6.801 6.1947 5.997 4.4681 6.9196 6.366 6.6955 4.244 7.7104 6.5637 5.8915 6.9328 5.417 4.903 5.5489 6.7482 5.8388 3.7563 4.1254 4.8239 5.2984 4.7317 0.7117 6.6428 3.9936 7.025 6.4715 7.2359 5.997 10.2278 11.2163 14.1291 4.7317 6.9855 3.9936 6.9328 5.4698 6.5374 6.4978 5.6279 5.4961 6.0365 4.679 5.9311 3.9936 6.8537 5.2193 5.2984 5.6148 7.4863 7.5654 7.3414 5.338 6.0761 5.8915 9.2525 5.2984 5.1403 6.8405 6.4583 6.5637 5.1271 6.4319 5.9311 11.8094 4.1254 4.8239 3.7563 5.8915 14.485 5.2984 6.2079 8.633 6.2079 5.8915 7.46 5.1271 7.4468 6.8273 5.338 3.6773 3.9936 5.9047 3.6773 5.997 16.3961 6.5242 5.997 5.9047 5.5884 3.9145 9.7006 7.4732 6.7482 3.9936 4.0595 3.9936 5.4566 46 2068 7.5259 4.4944 6.2079 12.5212 6.2869 6.7219 7.7499 8.3035 8.4089 4.2704 6.1288 5.3907 10.241 7.025 6.4187 9.7665 9.7006 6.0497 6.1156 9.7006 6.4978 6.6692 5.0085 8.9625 6.6428 7.7104 5.9311 5.9311 6.4187 5.193 4.2704 3.7563 4.6526 5.8915 4.8767 3.9936 9.4765 4.2704 3.9936 5.8915 6.5505 4.6658 4.1913 3.6773 4.8503 6.3265 6.8537 6.4715 7.5259 6.7482 6.7219 2.9524 4.7844 8.9625 5.4039 6.9591 5.3643 5.6148 5.5884 6.2342 4.8239 5.1798 3.9936 5.4698 4.2704 5.9443 6.511 5.3248 3.9936 12.1521 6.0365 4.1254 4.2704 7.5522 6.9328 5.3907 7.7104 6.4978 4.1254 6.9328 9.4765 6.2738 6.7746 3.9936 4.2704 11.8094 5.4961 8.5671 6.801 6.1947 5.997 4.4681 6.9196 6.366 6.6955 4.244 7.7104 6.5637 5.8915 6.9328 5.417 4.903 5.5489 6.7482 5.8388 3.7563 4.1254 4.8239 5.2984 4.7317 0.7117 6.6428 3.9936 7.025 6.4715 7.2359 5.997 10.2278 11.2163 14.1291 4.7317 6.9855 3.9936 6.9328 5.4698 6.5374 6.4978 5.6279 5.4961 6.0365 4.679 5.9311 3.9936 6.8537 5.2193 5.2984 5.6148 7.4863 7.5654 7.3414 5.338 6.0761 5.8915 9.2525 5.2984 5.1403 6.8405 6.4583 6.5637 5.1271 6.4319 5.9311 11.8094 4.1254 4.8239 3.7563 5.8915 14.485 5.2984 6.2079 8.633 6.2079 5.8915 7.46 5.1271 7.4468 6.8273 5.338 3.6773 3.9936 5.9047 3.6773 5.997 16.3961 6.5242 5.997 5.9047 5.5884 3.9145 9.7006 7.4732 6.7482 3.9936 4.0595 3.9936 5.4566 47 2069 7.5259 4.4944 6.2079 12.5212 6.2869 6.7219 7.7499 8.3035 8.4089 4.2704 6.1288 5.3907 10.241 7.025 6.4187 9.7665 9.7006 6.0497 6.1156 9.7006 6.4978 6.6692 5.0085 8.9625 6.6428 7.7104 5.9311 5.9311 6.4187 5.193 4.2704 3.7563 4.6526 5.8915 4.8767 3.9936 9.4765 4.2704 3.9936 5.8915 6.5505 4.6658 4.1913 3.6773 4.8503 6.3265 6.8537 6.4715 7.5259 6.7482 6.7219 2.9524 4.7844 8.9625 5.4039 6.9591 5.3643 5.6148 5.5884 6.2342 4.8239 5.1798 3.9936 5.4698 4.2704 5.9443 6.511 5.3248 3.9936 12.1521 6.0365 4.1254 4.2704 7.5522 6.9328 5.3907 7.7104 6.4978 4.1254 6.9328 9.4765 6.2738 6.7746 3.9936 4.2704 11.8094 5.4961 8.5671 6.801 6.1947 5.997 4.4681 6.9196 6.366 6.6955 4.244 7.7104 6.5637 5.8915 6.9328 5.417 4.903 5.5489 6.7482 5.8388 3.7563 4.1254 4.8239 5.2984 4.7317 0.7117 6.6428 3.9936 7.025 6.4715 7.2359 5.997 10.2278 11.2163 14.1291 4.7317 6.9855 3.9936 6.9328 5.4698 6.5374 6.4978 5.6279 5.4961 6.0365 4.679 5.9311 3.9936 6.8537 5.2193 5.2984 5.6148 7.4863 7.5654 7.3414 5.338 6.0761 5.8915 9.2525 5.2984 5.1403 6.8405 6.4583 6.5637 5.1271 6.4319 5.9311 11.8094 4.1254 4.8239 3.7563 5.8915 14.485 5.2984 6.2079 8.633 6.2079 5.8915 7.46 5.1271 7.4468 6.8273 5.338 3.6773 3.9936 5.9047 3.6773 5.997 16.3961 6.5242 5.997 5.9047 5.5884 3.9145 9.7006 7.4732 6.7482 3.9936 4.0595 3.9936 5.4566 48 2070 7.5259 4.4944 6.2079 12.5212 6.2869 6.7219 7.7499 8.3035 8.4089 4.2704 6.1288 5.3907 10.241 7.025 6.4187 9.7665 9.7006 6.0497 6.1156 9.7006 6.4978 6.6692 5.0085 8.9625 6.6428 7.7104 5.9311 5.9311 6.4187 5.193 4.2704 3.7563 4.6526 5.8915 4.8767 3.9936 9.4765 4.2704 3.9936 5.8915 6.5505 4.6658 4.1913 3.6773 4.8503 6.3265 6.8537 6.4715 7.5259 6.7482 6.7219 2.9524 4.7844 8.9625 5.4039 6.9591 5.3643 5.6148 5.5884 6.2342 4.8239 5.1798 3.9936 5.4698 4.2704 5.9443 6.511 5.3248 3.9936 12.1521 6.0365 4.1254 4.2704 7.5522 6.9328 5.3907 7.7104 6.4978 4.1254 6.9328 9.4765 6.2738 6.7746 3.9936 4.2704 11.8094 5.4961 8.5671 6.801 6.1947 5.997 4.4681 6.9196 6.366 6.6955 4.244 7.7104 6.5637 5.8915 6.9328 5.417 4.903 5.5489 6.7482 5.8388 3.7563 4.1254 4.8239 5.2984 4.7317 0.7117 6.6428 3.9936 7.025 6.4715 7.2359 5.997 10.2278 11.2163 14.1291 4.7317 6.9855 3.9936 6.9328 5.4698 6.5374 6.4978 5.6279 5.4961 6.0365 4.679 5.9311 3.9936 6.8537 5.2193 5.2984 5.6148 7.4863 7.5654 7.3414 5.338 6.0761 5.8915 9.2525 5.2984 5.1403 6.8405 6.4583 6.5637 5.1271 6.4319 5.9311 11.8094 4.1254 4.8239 3.7563 5.8915 14.485 5.2984 6.2079 8.633 6.2079 5.8915 7.46 5.1271 7.4468 6.8273 5.338 3.6773 3.9936 5.9047 3.6773 5.997 16.3961 6.5242 5.997 5.9047 5.5884 3.9145 9.7006 7.4732 6.7482 3.9936 4.0595 3.9936 5.4566 49 2071 7.5259 4.4944 6.2079 12.5212 6.2869 6.7219 7.7499 8.3035 8.4089 4.2704 6.1288 5.3907 10.241 7.025 6.4187 9.7665 9.7006 6.0497 6.1156 9.7006 6.4978 6.6692 5.0085 8.9625 6.6428 7.7104 5.9311 5.9311 6.4187 5.193 4.2704 3.7563 4.6526 5.8915 4.8767 3.9936 9.4765 4.2704 3.9936 5.8915 6.5505 4.6658 4.1913 3.6773 4.8503 6.3265 6.8537 6.4715 7.5259 6.7482 6.7219 2.9524 4.7844 8.9625 5.4039 6.9591 5.3643 5.6148 5.5884 6.2342 4.8239 5.1798 3.9936 5.4698 4.2704 5.9443 6.511 5.3248 3.9936 12.1521 6.0365 4.1254 4.2704 7.5522 6.9328 5.3907 7.7104 6.4978 4.1254 6.9328 9.4765 6.2738 6.7746 3.9936 4.2704 11.8094 5.4961 8.5671 6.801 6.1947 5.997 4.4681 6.9196 6.366 6.6955 4.244 7.7104 6.5637 5.8915 6.9328 5.417 4.903 5.5489 6.7482 5.8388 3.7563 4.1254 4.8239 5.2984 4.7317 0.7117 6.6428 3.9936 7.025 6.4715 7.2359 5.997 10.2278 11.2163 14.1291 4.7317 6.9855 3.9936 6.9328 5.4698 6.5374 6.4978 5.6279 5.4961 6.0365 4.679 5.9311 3.9936 6.8537 5.2193 5.2984 5.6148 7.4863 7.5654 7.3414 5.338 6.0761 5.8915 9.2525 5.2984 5.1403 6.8405 6.4583 6.5637 5.1271 6.4319 5.9311 11.8094 4.1254 4.8239 3.7563 5.8915 14.485 5.2984 6.2079 8.633 6.2079 5.8915 7.46 5.1271 7.4468 6.8273 5.338 3.6773 3.9936 5.9047 3.6773 5.997 16.3961 6.5242 5.997 5.9047 5.5884 3.9145 9.7006 7.4732 6.7482 3.9936 4.0595 3.9936 5.4566 50 2072 7.5259 4.4944 6.2079 12.5212 6.2869 6.7219 7.7499 8.3035 8.4089 4.2704 6.1288 5.3907 10.241 7.025 6.4187 9.7665 9.7006 6.0497 6.1156 9.7006 6.4978 6.6692 5.0085 8.9625 6.6428 7.7104 5.9311 5.9311 6.4187 5.193 4.2704 3.7563 4.6526 5.8915 4.8767 3.9936 9.4765 4.2704 3.9936 5.8915 6.5505 4.6658 4.1913 3.6773 4.8503 6.3265 6.8537 6.4715 7.5259 6.7482 6.7219 2.9524 4.7844 8.9625 5.4039 6.9591 5.3643 5.6148 5.5884 6.2342 4.8239 5.1798 3.9936 5.4698 4.2704 5.9443 6.511 5.3248 3.9936 12.1521 6.0365 4.1254 4.2704 7.5522 6.9328 5.3907 7.7104 6.4978 4.1254 6.9328 9.4765 6.2738 6.7746 3.9936 4.2704 11.8094 5.4961 8.5671 6.801 6.1947 5.997 4.4681 6.9196 6.366 6.6955 4.244 7.7104 6.5637 5.8915 6.9328 5.417 4.903 5.5489 6.7482 5.8388 3.7563 4.1254 4.8239 5.2984 4.7317 0.7117 6.6428 3.9936 7.025 6.4715 7.2359 5.997 10.2278 11.2163 14.1291 4.7317 6.9855 3.9936 6.9328 5.4698 6.5374 6.4978 5.6279 5.4961 6.0365 4.679 5.9311 3.9936 6.8537 5.2193 5.2984 5.6148 7.4863 7.5654 7.3414 5.338 6.0761 5.8915 9.2525 5.2984 5.1403 6.8405 6.4583 6.5637 5.1271 6.4319 5.9311 11.8094 4.1254 4.8239 3.7563 5.8915 14.485 5.2984 6.2079 8.633 6.2079 5.8915 7.46 5.1271 7.4468 6.8273 5.338 3.6773 3.9936 5.9047 3.6773 5.997 16.3961 6.5242 5.997 5.9047 5.5884 3.9145 9.7006 7.4732 6.7482 3.9936 4.0595 3.9936 5.4566 51 2073 7.5259 4.4944 6.2079 12.5212 6.2869 6.7219 7.7499 8.3035 8.4089 4.2704 6.1288 5.3907 10.241 7.025 6.4187 9.7665 9.7006 6.0497 6.1156 9.7006 6.4978 6.6692 5.0085 8.9625 6.6428 7.7104 5.9311 5.9311 6.4187 5.193 4.2704 3.7563 4.6526 5.8915 4.8767 3.9936 9.4765 4.2704 3.9936 5.8915 6.5505 4.6658 4.1913 3.6773 4.8503 6.3265 6.8537 6.4715 7.5259 6.7482 6.7219 2.9524 4.7844 8.9625 5.4039 6.9591 5.3643 5.6148 5.5884 6.2342 4.8239 5.1798 3.9936 5.4698 4.2704 5.9443 6.511 5.3248 3.9936 12.1521 6.0365 4.1254 4.2704 7.5522 6.9328 5.3907 7.7104 6.4978 4.1254 6.9328 9.4765 6.2738 6.7746 3.9936 4.2704 11.8094 5.4961 8.5671 6.801 6.1947 5.997 4.4681 6.9196 6.366 6.6955 4.244 7.7104 6.5637 5.8915 6.9328 5.417 4.903 5.5489 6.7482 5.8388 3.7563 4.1254 4.8239 5.2984 4.7317 0.7117 6.6428 3.9936 7.025 6.4715 7.2359 5.997 10.2278 11.2163 14.1291 4.7317 6.9855 3.9936 6.9328 5.4698 6.5374 6.4978 5.6279 5.4961 6.0365 4.679 5.9311 3.9936 6.8537 5.2193 5.2984 5.6148 7.4863 7.5654 7.3414 5.338 6.0761 5.8915 9.2525 5.2984 5.1403 6.8405 6.4583 6.5637 5.1271 6.4319 5.9311 11.8094 4.1254 4.8239 3.7563 5.8915 14.485 5.2984 6.2079 8.633 6.2079 5.8915 7.46 5.1271 7.4468 6.8273 5.338 3.6773 3.9936 5.9047 3.6773 5.997 16.3961 6.5242 5.997 5.9047 5.5884 3.9145 9.7006 7.4732 6.7482 3.9936 4.0595 3.9936 5.4566 52 2074 7.5259 4.4944 6.2079 12.5212 6.2869 6.7219 7.7499 8.3035 8.4089 4.2704 6.1288 5.3907 10.241 7.025 6.4187 9.7665 9.7006 6.0497 6.1156 9.7006 6.4978 6.6692 5.0085 8.9625 6.6428 7.7104 5.9311 5.9311 6.4187 5.193 4.2704 3.7563 4.6526 5.8915 4.8767 3.9936 9.4765 4.2704 3.9936 5.8915 6.5505 4.6658 4.1913 3.6773 4.8503 6.3265 6.8537 6.4715 7.5259 6.7482 6.7219 2.9524 4.7844 8.9625 5.4039 6.9591 5.3643 5.6148 5.5884 6.2342 4.8239 5.1798 3.9936 5.4698 4.2704 5.9443 6.511 5.3248 3.9936 12.1521 6.0365 4.1254 4.2704 7.5522 6.9328 5.3907 7.7104 6.4978 4.1254 6.9328 9.4765 6.2738 6.7746 3.9936 4.2704 11.8094 5.4961 8.5671 6.801 6.1947 5.997 4.4681 6.9196 6.366 6.6955 4.244 7.7104 6.5637 5.8915 6.9328 5.417 4.903 5.5489 6.7482 5.8388 3.7563 4.1254 4.8239 5.2984 4.7317 0.7117 6.6428 3.9936 7.025 6.4715 7.2359 5.997 10.2278 11.2163 14.1291 4.7317 6.9855 3.9936 6.9328 5.4698 6.5374 6.4978 5.6279 5.4961 6.0365 4.679 5.9311 3.9936 6.8537 5.2193 5.2984 5.6148 7.4863 7.5654 7.3414 5.338 6.0761 5.8915 9.2525 5.2984 5.1403 6.8405 6.4583 6.5637 5.1271 6.4319 5.9311 11.8094 4.1254 4.8239 3.7563 5.8915 14.485 5.2984 6.2079 8.633 6.2079 5.8915 7.46 5.1271 7.4468 6.8273 5.338 3.6773 3.9936 5.9047 3.6773 5.997 16.3961 6.5242 5.997 5.9047 5.5884 3.9145 9.7006 7.4732 6.7482 3.9936 4.0595 3.9936 5.4566 53 2075 7.5259 4.4944 6.2079 12.5212 6.2869 6.7219 7.7499 8.3035 8.4089 4.2704 6.1288 5.3907 10.241 7.025 6.4187 9.7665 9.7006 6.0497 6.1156 9.7006 6.4978 6.6692 5.0085 8.9625 6.6428 7.7104 5.9311 5.9311 6.4187 5.193 4.2704 3.7563 4.6526 5.8915 4.8767 3.9936 9.4765 4.2704 3.9936 5.8915 6.5505 4.6658 4.1913 3.6773 4.8503 6.3265 6.8537 6.4715 7.5259 6.7482 6.7219 2.9524 4.7844 8.9625 5.4039 6.9591 5.3643 5.6148 5.5884 6.2342 4.8239 5.1798 3.9936 5.4698 4.2704 5.9443 6.511 5.3248 3.9936 12.1521 6.0365 4.1254 4.2704 7.5522 6.9328 5.3907 7.7104 6.4978 4.1254 6.9328 9.4765 6.2738 6.7746 3.9936 4.2704 11.8094 5.4961 8.5671 6.801 6.1947 5.997 4.4681 6.9196 6.366 6.6955 4.244 7.7104 6.5637 5.8915 6.9328 5.417 4.903 5.5489 6.7482 5.8388 3.7563 4.1254 4.8239 5.2984 4.7317 0.7117 6.6428 3.9936 7.025 6.4715 7.2359 5.997 10.2278 11.2163 14.1291 4.7317 6.9855 3.9936 6.9328 5.4698 6.5374 6.4978 5.6279 5.4961 6.0365 4.679 5.9311 3.9936 6.8537 5.2193 5.2984 5.6148 7.4863 7.5654 7.3414 5.338 6.0761 5.8915 9.2525 5.2984 5.1403 6.8405 6.4583 6.5637 5.1271 6.4319 5.9311 11.8094 4.1254 4.8239 3.7563 5.8915 14.485 5.2984 6.2079 8.633 6.2079 5.8915 7.46 5.1271 7.4468 6.8273 5.338 3.6773 3.9936 5.9047 3.6773 5.997 16.3961 6.5242 5.997 5.9047 5.5884 3.9145 9.7006 7.4732 6.7482 3.9936 4.0595 3.9936 5.4566 54 2076 7.5259 4.4944 6.2079 12.5212 6.2869 6.7219 7.7499 8.3035 8.4089 4.2704 6.1288 5.3907 10.241 7.025 6.4187 9.7665 9.7006 6.0497 6.1156 9.7006 6.4978 6.6692 5.0085 8.9625 6.6428 7.7104 5.9311 5.9311 6.4187 5.193 4.2704 3.7563 4.6526 5.8915 4.8767 3.9936 9.4765 4.2704 3.9936 5.8915 6.5505 4.6658 4.1913 3.6773 4.8503 6.3265 6.8537 6.4715 7.5259 6.7482 6.7219 2.9524 4.7844 8.9625 5.4039 6.9591 5.3643 5.6148 5.5884 6.2342 4.8239 5.1798 3.9936 5.4698 4.2704 5.9443 6.511 5.3248 3.9936 12.1521 6.0365 4.1254 4.2704 7.5522 6.9328 5.3907 7.7104 6.4978 4.1254 6.9328 9.4765 6.2738 6.7746 3.9936 4.2704 11.8094 5.4961 8.5671 6.801 6.1947 5.997 4.4681 6.9196 6.366 6.6955 4.244 7.7104 6.5637 5.8915 6.9328 5.417 4.903 5.5489 6.7482 5.8388 3.7563 4.1254 4.8239 5.2984 4.7317 0.7117 6.6428 3.9936 7.025 6.4715 7.2359 5.997 10.2278 11.2163 14.1291 4.7317 6.9855 3.9936 6.9328 5.4698 6.5374 6.4978 5.6279 5.4961 6.0365 4.679 5.9311 3.9936 6.8537 5.2193 5.2984 5.6148 7.4863 7.5654 7.3414 5.338 6.0761 5.8915 9.2525 5.2984 5.1403 6.8405 6.4583 6.5637 5.1271 6.4319 5.9311 11.8094 4.1254 4.8239 3.7563 5.8915 14.485 5.2984 6.2079 8.633 6.2079 5.8915 7.46 5.1271 7.4468 6.8273 5.338 3.6773 3.9936 5.9047 3.6773 5.997 16.3961 6.5242 5.997 5.9047 5.5884 3.9145 9.7006 7.4732 6.7482 3.9936 4.0595 3.9936 5.4566 55 2077 7.5259 4.4944 6.2079 12.5212 6.2869 6.7219 7.7499 8.3035 8.4089 4.2704 6.1288 5.3907 10.241 7.025 6.4187 9.7665 9.7006 6.0497 6.1156 9.7006 6.4978 6.6692 5.0085 8.9625 6.6428 7.7104 5.9311 5.9311 6.4187 5.193 4.2704 3.7563 4.6526 5.8915 4.8767 3.9936 9.4765 4.2704 3.9936 5.8915 6.5505 4.6658 4.1913 3.6773 4.8503 6.3265 6.8537 6.4715 7.5259 6.7482 6.7219 2.9524 4.7844 8.9625 5.4039 6.9591 5.3643 5.6148 5.5884 6.2342 4.8239 5.1798 3.9936 5.4698 4.2704 5.9443 6.511 5.3248 3.9936 12.1521 6.0365 4.1254 4.2704 7.5522 6.9328 5.3907 7.7104 6.4978 4.1254 6.9328 9.4765 6.2738 6.7746 3.9936 4.2704 11.8094 5.4961 8.5671 6.801 6.1947 5.997 4.4681 6.9196 6.366 6.6955 4.244 7.7104 6.5637 5.8915 6.9328 5.417 4.903 5.5489 6.7482 5.8388 3.7563 4.1254 4.8239 5.2984 4.7317 0.7117 6.6428 3.9936 7.025 6.4715 7.2359 5.997 10.2278 11.2163 14.1291 4.7317 6.9855 3.9936 6.9328 5.4698 6.5374 6.4978 5.6279 5.4961 6.0365 4.679 5.9311 3.9936 6.8537 5.2193 5.2984 5.6148 7.4863 7.5654 7.3414 5.338 6.0761 5.8915 9.2525 5.2984 5.1403 6.8405 6.4583 6.5637 5.1271 6.4319 5.9311 11.8094 4.1254 4.8239 3.7563 5.8915 14.485 5.2984 6.2079 8.633 6.2079 5.8915 7.46 5.1271 7.4468 6.8273 5.338 3.6773 3.9936 5.9047 3.6773 5.997 16.3961 6.5242 5.997 5.9047 5.5884 3.9145 9.7006 7.4732 6.7482 3.9936 4.0595 3.9936 5.4566 56 2078 7.5259 4.4944 6.2079 12.5212 6.2869 6.7219 7.7499 8.3035 8.4089 4.2704 6.1288 5.3907 10.241 7.025 6.4187 9.7665 9.7006 6.0497 6.1156 9.7006 6.4978 6.6692 5.0085 8.9625 6.6428 7.7104 5.9311 5.9311 6.4187 5.193 4.2704 3.7563 4.6526 5.8915 4.8767 3.9936 9.4765 4.2704 3.9936 5.8915 6.5505 4.6658 4.1913 3.6773 4.8503 6.3265 6.8537 6.4715 7.5259 6.7482 6.7219 2.9524 4.7844 8.9625 5.4039 6.9591 5.3643 5.6148 5.5884 6.2342 4.8239 5.1798 3.9936 5.4698 4.2704 5.9443 6.511 5.3248 3.9936 12.1521 6.0365 4.1254 4.2704 7.5522 6.9328 5.3907 7.7104 6.4978 4.1254 6.9328 9.4765 6.2738 6.7746 3.9936 4.2704 11.8094 5.4961 8.5671 6.801 6.1947 5.997 4.4681 6.9196 6.366 6.6955 4.244 7.7104 6.5637 5.8915 6.9328 5.417 4.903 5.5489 6.7482 5.8388 3.7563 4.1254 4.8239 5.2984 4.7317 0.7117 6.6428 3.9936 7.025 6.4715 7.2359 5.997 10.2278 11.2163 14.1291 4.7317 6.9855 3.9936 6.9328 5.4698 6.5374 6.4978 5.6279 5.4961 6.0365 4.679 5.9311 3.9936 6.8537 5.2193 5.2984 5.6148 7.4863 7.5654 7.3414 5.338 6.0761 5.8915 9.2525 5.2984 5.1403 6.8405 6.4583 6.5637 5.1271 6.4319 5.9311 11.8094 4.1254 4.8239 3.7563 5.8915 14.485 5.2984 6.2079 8.633 6.2079 5.8915 7.46 5.1271 7.4468 6.8273 5.338 3.6773 3.9936 5.9047 3.6773 5.997 16.3961 6.5242 5.997 5.9047 5.5884 3.9145 9.7006 7.4732 6.7482 3.9936 4.0595 3.9936 5.4566 57 2079 7.5259 4.4944 6.2079 12.5212 6.2869 6.7219 7.7499 8.3035 8.4089 4.2704 6.1288 5.3907 10.241 7.025 6.4187 9.7665 9.7006 6.0497 6.1156 9.7006 6.4978 6.6692 5.0085 8.9625 6.6428 7.7104 5.9311 5.9311 6.4187 5.193 4.2704 3.7563 4.6526 5.8915 4.8767 3.9936 9.4765 4.2704 3.9936 5.8915 6.5505 4.6658 4.1913 3.6773 4.8503 6.3265 6.8537 6.4715 7.5259 6.7482 6.7219 2.9524 4.7844 8.9625 5.4039 6.9591 5.3643 5.6148 5.5884 6.2342 4.8239 5.1798 3.9936 5.4698 4.2704 5.9443 6.511 5.3248 3.9936 12.1521 6.0365 4.1254 4.2704 7.5522 6.9328 5.3907 7.7104 6.4978 4.1254 6.9328 9.4765 6.2738 6.7746 3.9936 4.2704 11.8094 5.4961 8.5671 6.801 6.1947 5.997 4.4681 6.9196 6.366 6.6955 4.244 7.7104 6.5637 5.8915 6.9328 5.417 4.903 5.5489 6.7482 5.8388 3.7563 4.1254 4.8239 5.2984 4.7317 0.7117 6.6428 3.9936 7.025 6.4715 7.2359 5.997 10.2278 11.2163 14.1291 4.7317 6.9855 3.9936 6.9328 5.4698 6.5374 6.4978 5.6279 5.4961 6.0365 4.679 5.9311 3.9936 6.8537 5.2193 5.2984 5.6148 7.4863 7.5654 7.3414 5.338 6.0761 5.8915 9.2525 5.2984 5.1403 6.8405 6.4583 6.5637 5.1271 6.4319 5.9311 11.8094 4.1254 4.8239 3.7563 5.8915 14.485 5.2984 6.2079 8.633 6.2079 5.8915 7.46 5.1271 7.4468 6.8273 5.338 3.6773 3.9936 5.9047 3.6773 5.997 16.3961 6.5242 5.997 5.9047 5.5884 3.9145 9.7006 7.4732 6.7482 3.9936 4.0595 3.9936 5.4566 58 2080 7.5259 4.4944 6.2079 12.5212 6.2869 6.7219 7.7499 8.3035 8.4089 4.2704 6.1288 5.3907 10.241 7.025 6.4187 9.7665 9.7006 6.0497 6.1156 9.7006 6.4978 6.6692 5.0085 8.9625 6.6428 7.7104 5.9311 5.9311 6.4187 5.193 4.2704 3.7563 4.6526 5.8915 4.8767 3.9936 9.4765 4.2704 3.9936 5.8915 6.5505 4.6658 4.1913 3.6773 4.8503 6.3265 6.8537 6.4715 7.5259 6.7482 6.7219 2.9524 4.7844 8.9625 5.4039 6.9591 5.3643 5.6148 5.5884 6.2342 4.8239 5.1798 3.9936 5.4698 4.2704 5.9443 6.511 5.3248 3.9936 12.1521 6.0365 4.1254 4.2704 7.5522 6.9328 5.3907 7.7104 6.4978 4.1254 6.9328 9.4765 6.2738 6.7746 3.9936 4.2704 11.8094 5.4961 8.5671 6.801 6.1947 5.997 4.4681 6.9196 6.366 6.6955 4.244 7.7104 6.5637 5.8915 6.9328 5.417 4.903 5.5489 6.7482 5.8388 3.7563 4.1254 4.8239 5.2984 4.7317 0.7117 6.6428 3.9936 7.025 6.4715 7.2359 5.997 10.2278 11.2163 14.1291 4.7317 6.9855 3.9936 6.9328 5.4698 6.5374 6.4978 5.6279 5.4961 6.0365 4.679 5.9311 3.9936 6.8537 5.2193 5.2984 5.6148 7.4863 7.5654 7.3414 5.338 6.0761 5.8915 9.2525 5.2984 5.1403 6.8405 6.4583 6.5637 5.1271 6.4319 5.9311 11.8094 4.1254 4.8239 3.7563 5.8915 14.485 5.2984 6.2079 8.633 6.2079 5.8915 7.46 5.1271 7.4468 6.8273 5.338 3.6773 3.9936 5.9047 3.6773 5.997 16.3961 6.5242 5.997 5.9047 5.5884 3.9145 9.7006 7.4732 6.7482 3.9936 4.0595 3.9936 5.4566 59 2081 7.5259 4.4944 6.2079 12.5212 6.2869 6.7219 7.7499 8.3035 8.4089 4.2704 6.1288 5.3907 10.241 7.025 6.4187 9.7665 9.7006 6.0497 6.1156 9.7006 6.4978 6.6692 5.0085 8.9625 6.6428 7.7104 5.9311 5.9311 6.4187 5.193 4.2704 3.7563 4.6526 5.8915 4.8767 3.9936 9.4765 4.2704 3.9936 5.8915 6.5505 4.6658 4.1913 3.6773 4.8503 6.3265 6.8537 6.4715 7.5259 6.7482 6.7219 2.9524 4.7844 8.9625 5.4039 6.9591 5.3643 5.6148 5.5884 6.2342 4.8239 5.1798 3.9936 5.4698 4.2704 5.9443 6.511 5.3248 3.9936 12.1521 6.0365 4.1254 4.2704 7.5522 6.9328 5.3907 7.7104 6.4978 4.1254 6.9328 9.4765 6.2738 6.7746 3.9936 4.2704 11.8094 5.4961 8.5671 6.801 6.1947 5.997 4.4681 6.9196 6.366 6.6955 4.244 7.7104 6.5637 5.8915 6.9328 5.417 4.903 5.5489 6.7482 5.8388 3.7563 4.1254 4.8239 5.2984 4.7317 0.7117 6.6428 3.9936 7.025 6.4715 7.2359 5.997 10.2278 11.2163 14.1291 4.7317 6.9855 3.9936 6.9328 5.4698 6.5374 6.4978 5.6279 5.4961 6.0365 4.679 5.9311 3.9936 6.8537 5.2193 5.2984 5.6148 7.4863 7.5654 7.3414 5.338 6.0761 5.8915 9.2525 5.2984 5.1403 6.8405 6.4583 6.5637 5.1271 6.4319 5.9311 11.8094 4.1254 4.8239 3.7563 5.8915 14.485 5.2984 6.2079 8.633 6.2079 5.8915 7.46 5.1271 7.4468 6.8273 5.338 3.6773 3.9936 5.9047 3.6773 5.997 16.3961 6.5242 5.997 5.9047 5.5884 3.9145 9.7006 7.4732 6.7482 3.9936 4.0595 3.9936 5.4566 60 2082 7.5259 4.4944 6.2079 12.5212 6.2869 6.7219 7.7499 8.3035 8.4089 4.2704 6.1288 5.3907 10.241 7.025 6.4187 9.7665 9.7006 6.0497 6.1156 9.7006 6.4978 6.6692 5.0085 8.9625 6.6428 7.7104 5.9311 5.9311 6.4187 5.193 4.2704 3.7563 4.6526 5.8915 4.8767 3.9936 9.4765 4.2704 3.9936 5.8915 6.5505 4.6658 4.1913 3.6773 4.8503 6.3265 6.8537 6.4715 7.5259 6.7482 6.7219 2.9524 4.7844 8.9625 5.4039 6.9591 5.3643 5.6148 5.5884 6.2342 4.8239 5.1798 3.9936 5.4698 4.2704 5.9443 6.511 5.3248 3.9936 12.1521 6.0365 4.1254 4.2704 7.5522 6.9328 5.3907 7.7104 6.4978 4.1254 6.9328 9.4765 6.2738 6.7746 3.9936 4.2704 11.8094 5.4961 8.5671 6.801 6.1947 5.997 4.4681 6.9196 6.366 6.6955 4.244 7.7104 6.5637 5.8915 6.9328 5.417 4.903 5.5489 6.7482 5.8388 3.7563 4.1254 4.8239 5.2984 4.7317 0.7117 6.6428 3.9936 7.025 6.4715 7.2359 5.997 10.2278 11.2163 14.1291 4.7317 6.9855 3.9936 6.9328 5.4698 6.5374 6.4978 5.6279 5.4961 6.0365 4.679 5.9311 3.9936 6.8537 5.2193 5.2984 5.6148 7.4863 7.5654 7.3414 5.338 6.0761 5.8915 9.2525 5.2984 5.1403 6.8405 6.4583 6.5637 5.1271 6.4319 5.9311 11.8094 4.1254 4.8239 3.7563 5.8915 14.485 5.2984 6.2079 8.633 6.2079 5.8915 7.46 5.1271 7.4468 6.8273 5.338 3.6773 3.9936 5.9047 3.6773 5.997 16.3961 6.5242 5.997 5.9047 5.5884 3.9145 9.7006 7.4732 6.7482 3.9936 4.0595 3.9936 5.4566 61 2083 7.5259 4.4944 6.2079 12.5212 6.2869 6.7219 7.7499 8.3035 8.4089 4.2704 6.1288 5.3907 10.241 7.025 6.4187 9.7665 9.7006 6.0497 6.1156 9.7006 6.4978 6.6692 5.0085 8.9625 6.6428 7.7104 5.9311 5.9311 6.4187 5.193 4.2704 3.7563 4.6526 5.8915 4.8767 3.9936 9.4765 4.2704 3.9936 5.8915 6.5505 4.6658 4.1913 3.6773 4.8503 6.3265 6.8537 6.4715 7.5259 6.7482 6.7219 2.9524 4.7844 8.9625 5.4039 6.9591 5.3643 5.6148 5.5884 6.2342 4.8239 5.1798 3.9936 5.4698 4.2704 5.9443 6.511 5.3248 3.9936 12.1521 6.0365 4.1254 4.2704 7.5522 6.9328 5.3907 7.7104 6.4978 4.1254 6.9328 9.4765 6.2738 6.7746 3.9936 4.2704 11.8094 5.4961 8.5671 6.801 6.1947 5.997 4.4681 6.9196 6.366 6.6955 4.244 7.7104 6.5637 5.8915 6.9328 5.417 4.903 5.5489 6.7482 5.8388 3.7563 4.1254 4.8239 5.2984 4.7317 0.7117 6.6428 3.9936 7.025 6.4715 7.2359 5.997 10.2278 11.2163 14.1291 4.7317 6.9855 3.9936 6.9328 5.4698 6.5374 6.4978 5.6279 5.4961 6.0365 4.679 5.9311 3.9936 6.8537 5.2193 5.2984 5.6148 7.4863 7.5654 7.3414 5.338 6.0761 5.8915 9.2525 5.2984 5.1403 6.8405 6.4583 6.5637 5.1271 6.4319 5.9311 11.8094 4.1254 4.8239 3.7563 5.8915 14.485 5.2984 6.2079 8.633 6.2079 5.8915 7.46 5.1271 7.4468 6.8273 5.338 3.6773 3.9936 5.9047 3.6773 5.997 16.3961 6.5242 5.997 5.9047 5.5884 3.9145 9.7006 7.4732 6.7482 3.9936 4.0595 3.9936 5.4566 62 2084 7.5259 4.4944 6.2079 12.5212 6.2869 6.7219 7.7499 8.3035 8.4089 4.2704 6.1288 5.3907 10.241 7.025 6.4187 9.7665 9.7006 6.0497 6.1156 9.7006 6.4978 6.6692 5.0085 8.9625 6.6428 7.7104 5.9311 5.9311 6.4187 5.193 4.2704 3.7563 4.6526 5.8915 4.8767 3.9936 9.4765 4.2704 3.9936 5.8915 6.5505 4.6658 4.1913 3.6773 4.8503 6.3265 6.8537 6.4715 7.5259 6.7482 6.7219 2.9524 4.7844 8.9625 5.4039 6.9591 5.3643 5.6148 5.5884 6.2342 4.8239 5.1798 3.9936 5.4698 4.2704 5.9443 6.511 5.3248 3.9936 12.1521 6.0365 4.1254 4.2704 7.5522 6.9328 5.3907 7.7104 6.4978 4.1254 6.9328 9.4765 6.2738 6.7746 3.9936 4.2704 11.8094 5.4961 8.5671 6.801 6.1947 5.997 4.4681 6.9196 6.366 6.6955 4.244 7.7104 6.5637 5.8915 6.9328 5.417 4.903 5.5489 6.7482 5.8388 3.7563 4.1254 4.8239 5.2984 4.7317 0.7117 6.6428 3.9936 7.025 6.4715 7.2359 5.997 10.2278 11.2163 14.1291 4.7317 6.9855 3.9936 6.9328 5.4698 6.5374 6.4978 5.6279 5.4961 6.0365 4.679 5.9311 3.9936 6.8537 5.2193 5.2984 5.6148 7.4863 7.5654 7.3414 5.338 6.0761 5.8915 9.2525 5.2984 5.1403 6.8405 6.4583 6.5637 5.1271 6.4319 5.9311 11.8094 4.1254 4.8239 3.7563 5.8915 14.485 5.2984 6.2079 8.633 6.2079 5.8915 7.46 5.1271 7.4468 6.8273 5.338 3.6773 3.9936 5.9047 3.6773 5.997 16.3961 6.5242 5.997 5.9047 5.5884 3.9145 9.7006 7.4732 6.7482 3.9936 4.0595 3.9936 5.4566 63 2085 7.5259 4.4944 6.2079 12.5212 6.2869 6.7219 7.7499 8.3035 8.4089 4.2704 6.1288 5.3907 10.241 7.025 6.4187 9.7665 9.7006 6.0497 6.1156 9.7006 6.4978 6.6692 5.0085 8.9625 6.6428 7.7104 5.9311 5.9311 6.4187 5.193 4.2704 3.7563 4.6526 5.8915 4.8767 3.9936 9.4765 4.2704 3.9936 5.8915 6.5505 4.6658 4.1913 3.6773 4.8503 6.3265 6.8537 6.4715 7.5259 6.7482 6.7219 2.9524 4.7844 8.9625 5.4039 6.9591 5.3643 5.6148 5.5884 6.2342 4.8239 5.1798 3.9936 5.4698 4.2704 5.9443 6.511 5.3248 3.9936 12.1521 6.0365 4.1254 4.2704 7.5522 6.9328 5.3907 7.7104 6.4978 4.1254 6.9328 9.4765 6.2738 6.7746 3.9936 4.2704 11.8094 5.4961 8.5671 6.801 6.1947 5.997 4.4681 6.9196 6.366 6.6955 4.244 7.7104 6.5637 5.8915 6.9328 5.417 4.903 5.5489 6.7482 5.8388 3.7563 4.1254 4.8239 5.2984 4.7317 0.7117 6.6428 3.9936 7.025 6.4715 7.2359 5.997 10.2278 11.2163 14.1291 4.7317 6.9855 3.9936 6.9328 5.4698 6.5374 6.4978 5.6279 5.4961 6.0365 4.679 5.9311 3.9936 6.8537 5.2193 5.2984 5.6148 7.4863 7.5654 7.3414 5.338 6.0761 5.8915 9.2525 5.2984 5.1403 6.8405 6.4583 6.5637 5.1271 6.4319 5.9311 11.8094 4.1254 4.8239 3.7563 5.8915 14.485 5.2984 6.2079 8.633 6.2079 5.8915 7.46 5.1271 7.4468 6.8273 5.338 3.6773 3.9936 5.9047 3.6773 5.997 16.3961 6.5242 5.997 5.9047 5.5884 3.9145 9.7006 7.4732 6.7482 3.9936 4.0595 3.9936 5.4566 64 2086 7.5259 4.4944 6.2079 12.5212 6.2869 6.7219 7.7499 8.3035 8.4089 4.2704 6.1288 5.3907 10.241 7.025 6.4187 9.7665 9.7006 6.0497 6.1156 9.7006 6.4978 6.6692 5.0085 8.9625 6.6428 7.7104 5.9311 5.9311 6.4187 5.193 4.2704 3.7563 4.6526 5.8915 4.8767 3.9936 9.4765 4.2704 3.9936 5.8915 6.5505 4.6658 4.1913 3.6773 4.8503 6.3265 6.8537 6.4715 7.5259 6.7482 6.7219 2.9524 4.7844 8.9625 5.4039 6.9591 5.3643 5.6148 5.5884 6.2342 4.8239 5.1798 3.9936 5.4698 4.2704 5.9443 6.511 5.3248 3.9936 12.1521 6.0365 4.1254 4.2704 7.5522 6.9328 5.3907 7.7104 6.4978 4.1254 6.9328 9.4765 6.2738 6.7746 3.9936 4.2704 11.8094 5.4961 8.5671 6.801 6.1947 5.997 4.4681 6.9196 6.366 6.6955 4.244 7.7104 6.5637 5.8915 6.9328 5.417 4.903 5.5489 6.7482 5.8388 3.7563 4.1254 4.8239 5.2984 4.7317 0.7117 6.6428 3.9936 7.025 6.4715 7.2359 5.997 10.2278 11.2163 14.1291 4.7317 6.9855 3.9936 6.9328 5.4698 6.5374 6.4978 5.6279 5.4961 6.0365 4.679 5.9311 3.9936 6.8537 5.2193 5.2984 5.6148 7.4863 7.5654 7.3414 5.338 6.0761 5.8915 9.2525 5.2984 5.1403 6.8405 6.4583 6.5637 5.1271 6.4319 5.9311 11.8094 4.1254 4.8239 3.7563 5.8915 14.485 5.2984 6.2079 8.633 6.2079 5.8915 7.46 5.1271 7.4468 6.8273 5.338 3.6773 3.9936 5.9047 3.6773 5.997 16.3961 6.5242 5.997 5.9047 5.5884 3.9145 9.7006 7.4732 6.7482 3.9936 4.0595 3.9936 5.4566 65 2087 7.5259 4.4944 6.2079 12.5212 6.2869 6.7219 7.7499 8.3035 8.4089 4.2704 6.1288 5.3907 10.241 7.025 6.4187 9.7665 9.7006 6.0497 6.1156 9.7006 6.4978 6.6692 5.0085 8.9625 6.6428 7.7104 5.9311 5.9311 6.4187 5.193 4.2704 3.7563 4.6526 5.8915 4.8767 3.9936 9.4765 4.2704 3.9936 5.8915 6.5505 4.6658 4.1913 3.6773 4.8503 6.3265 6.8537 6.4715 7.5259 6.7482 6.7219 2.9524 4.7844 8.9625 5.4039 6.9591 5.3643 5.6148 5.5884 6.2342 4.8239 5.1798 3.9936 5.4698 4.2704 5.9443 6.511 5.3248 3.9936 12.1521 6.0365 4.1254 4.2704 7.5522 6.9328 5.3907 7.7104 6.4978 4.1254 6.9328 9.4765 6.2738 6.7746 3.9936 4.2704 11.8094 5.4961 8.5671 6.801 6.1947 5.997 4.4681 6.9196 6.366 6.6955 4.244 7.7104 6.5637 5.8915 6.9328 5.417 4.903 5.5489 6.7482 5.8388 3.7563 4.1254 4.8239 5.2984 4.7317 0.7117 6.6428 3.9936 7.025 6.4715 7.2359 5.997 10.2278 11.2163 14.1291 4.7317 6.9855 3.9936 6.9328 5.4698 6.5374 6.4978 5.6279 5.4961 6.0365 4.679 5.9311 3.9936 6.8537 5.2193 5.2984 5.6148 7.4863 7.5654 7.3414 5.338 6.0761 5.8915 9.2525 5.2984 5.1403 6.8405 6.4583 6.5637 5.1271 6.4319 5.9311 11.8094 4.1254 4.8239 3.7563 5.8915 14.485 5.2984 6.2079 8.633 6.2079 5.8915 7.46 5.1271 7.4468 6.8273 5.338 3.6773 3.9936 5.9047 3.6773 5.997 16.3961 6.5242 5.997 5.9047 5.5884 3.9145 9.7006 7.4732 6.7482 3.9936 4.0595 3.9936 5.4566 66 2088 7.5259 4.4944 6.2079 12.5212 6.2869 6.7219 7.7499 8.3035 8.4089 4.2704 6.1288 5.3907 10.241 7.025 6.4187 9.7665 9.7006 6.0497 6.1156 9.7006 6.4978 6.6692 5.0085 8.9625 6.6428 7.7104 5.9311 5.9311 6.4187 5.193 4.2704 3.7563 4.6526 5.8915 4.8767 3.9936 9.4765 4.2704 3.9936 5.8915 6.5505 4.6658 4.1913 3.6773 4.8503 6.3265 6.8537 6.4715 7.5259 6.7482 6.7219 2.9524 4.7844 8.9625 5.4039 6.9591 5.3643 5.6148 5.5884 6.2342 4.8239 5.1798 3.9936 5.4698 4.2704 5.9443 6.511 5.3248 3.9936 12.1521 6.0365 4.1254 4.2704 7.5522 6.9328 5.3907 7.7104 6.4978 4.1254 6.9328 9.4765 6.2738 6.7746 3.9936 4.2704 11.8094 5.4961 8.5671 6.801 6.1947 5.997 4.4681 6.9196 6.366 6.6955 4.244 7.7104 6.5637 5.8915 6.9328 5.417 4.903 5.5489 6.7482 5.8388 3.7563 4.1254 4.8239 5.2984 4.7317 0.7117 6.6428 3.9936 7.025 6.4715 7.2359 5.997 10.2278 11.2163 14.1291 4.7317 6.9855 3.9936 6.9328 5.4698 6.5374 6.4978 5.6279 5.4961 6.0365 4.679 5.9311 3.9936 6.8537 5.2193 5.2984 5.6148 7.4863 7.5654 7.3414 5.338 6.0761 5.8915 9.2525 5.2984 5.1403 6.8405 6.4583 6.5637 5.1271 6.4319 5.9311 11.8094 4.1254 4.8239 3.7563 5.8915 14.485 5.2984 6.2079 8.633 6.2079 5.8915 7.46 5.1271 7.4468 6.8273 5.338 3.6773 3.9936 5.9047 3.6773 5.997 16.3961 6.5242 5.997 5.9047 5.5884 3.9145 9.7006 7.4732 6.7482 3.9936 4.0595 3.9936 5.4566 67 2089 7.5259 4.4944 6.2079 12.5212 6.2869 6.7219 7.7499 8.3035 8.4089 4.2704 6.1288 5.3907 10.241 7.025 6.4187 9.7665 9.7006 6.0497 6.1156 9.7006 6.4978 6.6692 5.0085 8.9625 6.6428 7.7104 5.9311 5.9311 6.4187 5.193 4.2704 3.7563 4.6526 5.8915 4.8767 3.9936 9.4765 4.2704 3.9936 5.8915 6.5505 4.6658 4.1913 3.6773 4.8503 6.3265 6.8537 6.4715 7.5259 6.7482 6.7219 2.9524 4.7844 8.9625 5.4039 6.9591 5.3643 5.6148 5.5884 6.2342 4.8239 5.1798 3.9936 5.4698 4.2704 5.9443 6.511 5.3248 3.9936 12.1521 6.0365 4.1254 4.2704 7.5522 6.9328 5.3907 7.7104 6.4978 4.1254 6.9328 9.4765 6.2738 6.7746 3.9936 4.2704 11.8094 5.4961 8.5671 6.801 6.1947 5.997 4.4681 6.9196 6.366 6.6955 4.244 7.7104 6.5637 5.8915 6.9328 5.417 4.903 5.5489 6.7482 5.8388 3.7563 4.1254 4.8239 5.2984 4.7317 0.7117 6.6428 3.9936 7.025 6.4715 7.2359 5.997 10.2278 11.2163 14.1291 4.7317 6.9855 3.9936 6.9328 5.4698 6.5374 6.4978 5.6279 5.4961 6.0365 4.679 5.9311 3.9936 6.8537 5.2193 5.2984 5.6148 7.4863 7.5654 7.3414 5.338 6.0761 5.8915 9.2525 5.2984 5.1403 6.8405 6.4583 6.5637 5.1271 6.4319 5.9311 11.8094 4.1254 4.8239 3.7563 5.8915 14.485 5.2984 6.2079 8.633 6.2079 5.8915 7.46 5.1271 7.4468 6.8273 5.338 3.6773 3.9936 5.9047 3.6773 5.997 16.3961 6.5242 5.997 5.9047 5.5884 3.9145 9.7006 7.4732 6.7482 3.9936 4.0595 3.9936 5.4566 68 2090 7.5259 4.4944 6.2079 12.5212 6.2869 6.7219 7.7499 8.3035 8.4089 4.2704 6.1288 5.3907 10.241 7.025 6.4187 9.7665 9.7006 6.0497 6.1156 9.7006 6.4978 6.6692 5.0085 8.9625 6.6428 7.7104 5.9311 5.9311 6.4187 5.193 4.2704 3.7563 4.6526 5.8915 4.8767 3.9936 9.4765 4.2704 3.9936 5.8915 6.5505 4.6658 4.1913 3.6773 4.8503 6.3265 6.8537 6.4715 7.5259 6.7482 6.7219 2.9524 4.7844 8.9625 5.4039 6.9591 5.3643 5.6148 5.5884 6.2342 4.8239 5.1798 3.9936 5.4698 4.2704 5.9443 6.511 5.3248 3.9936 12.1521 6.0365 4.1254 4.2704 7.5522 6.9328 5.3907 7.7104 6.4978 4.1254 6.9328 9.4765 6.2738 6.7746 3.9936 4.2704 11.8094 5.4961 8.5671 6.801 6.1947 5.997 4.4681 6.9196 6.366 6.6955 4.244 7.7104 6.5637 5.8915 6.9328 5.417 4.903 5.5489 6.7482 5.8388 3.7563 4.1254 4.8239 5.2984 4.7317 0.7117 6.6428 3.9936 7.025 6.4715 7.2359 5.997 10.2278 11.2163 14.1291 4.7317 6.9855 3.9936 6.9328 5.4698 6.5374 6.4978 5.6279 5.4961 6.0365 4.679 5.9311 3.9936 6.8537 5.2193 5.2984 5.6148 7.4863 7.5654 7.3414 5.338 6.0761 5.8915 9.2525 5.2984 5.1403 6.8405 6.4583 6.5637 5.1271 6.4319 5.9311 11.8094 4.1254 4.8239 3.7563 5.8915 14.485 5.2984 6.2079 8.633 6.2079 5.8915 7.46 5.1271 7.4468 6.8273 5.338 3.6773 3.9936 5.9047 3.6773 5.997 16.3961 6.5242 5.997 5.9047 5.5884 3.9145 9.7006 7.4732 6.7482 3.9936 4.0595 3.9936 5.4566 Natural Gas Projections, 2025 2025 Assumed real growth rate 2022-2027 based on Hilcorp contract price with CEA, 2028-2050 forward based on EIA Henry Hub, held constant post-2050 Nominal contract price $2025 per Mcf Prices held constant after 2050 2022 Hilcorp Contract Prices (nominal) 7.585 7.585 2023 7.655 7.655 2024 7.745 7.745 2025 7.83 7.83 2026 7.92 7.92 2027 8.01 8.01 2028 8.3461 4.19634521738087E-02 OK 2029 8.8492 0.060273911546374 OK 2030 9.4218 6.47126863976983E-02 OK 2031 9.8699 4.75590019628934E-02 OK 2032 11.3292 0.147850176351711 OK 2033 12.5507 0.107820352078281 OK 2034 13.266 5.69942380892383E-02 OK 2035 13.5432 0.020889315067288 OK 2036 13.5341 -6.71499365231646E-04 OK 2037 13.374 -1.18270416022992E-02 OK 2038 13.1813 -1.44058357656841E-02 OK 2039 12.9839 -1.49775213227038E-02 OK 2040 13.0572 5.6450639761933E-03 OK 2041 13.2921 0.017987874535575 OK 2042 13.5238 1.74305529870922E-02 OK 2043 13.936 3.04799994218161E-02 OK 2044 14.1931 1.84545767917808E-02 OK 2045 14.3684 1.23498537659319E-02 OK 2046 14.6319 1.83355974260413E-02 OK 2047 14.7809 1.01818392096123E-02 OK 2048 14.7706 -6.922526428033E-04 OK 2049 14.7022 -4.63451068505325E-03 OK 2050 14.6938 -5.69248476910498E-04 OK 2051 14.6938 0 2052 14.6938 0 2053 14.6938 0 2054 14.6938 0 2055 14.6938 0 2056 14.6938 0 2057 14.6938 0 2058 14.6938 0 2059 14.6938 0 2060 14.6938 0 2061 14.6938 0 2062 14.6938 0 2063 14.6938 0 2064 14.6938 0 2065 14.6938 0 2066 14.6938 0 2067 14.6938 0 2068 14.6938 0 2069 14.6938 0 2070 14.6938 0 2071 14.6938 0 2072 14.6938 0 2073 14.6938 0 2074 14.6938 0 2075 14.6938 0 2076 14.6938 0 2077 14.6938 0 2078 14.6938 0 2079 14.6938 0 2080 14.6938 0 2081 14.6938 0 2082 14.6938 0 2083 14.6938 0 2084 14.6938 0 2085 14.6938 0 2086 14.6938 0 2087 14.6938 0 2088 14.6938 0 2089 14.6938 0 2090 14.6938 0 PPP000:ba_WorldOilPrice PPP000:bb_ForeignLSLigh PPP000:bb_Imported_Real PPP000:see_spot_markup PPP000:da_LiquefiedPetr PPP000:da_DistillateFue PPP000:ea_DistillateFue PPP000:ea_ResidualFuel PPP000:ea_ResidualFuel( PPP000:fa_LiquefiedPetr PPP000:fa_DistillateFue PPP000:fa_ResidualFuel PPP000:fa_ResidualFuel( PPP000:ga_LiquefiedPetr PPP000:ga_Ethanol(E85) PPP000:pr_EthanolWhole PPP000:ga_MotorGasoline PPP000:ga_JetFuel PPP000:ga_DieselFuel(Di PPP000:ga_ResidualFuel PPP000:ga_ResidualFuel( PPP000:ha_DistillateFue PPP000:ha_ResidualFuel PPP000:ha_ResidualFuel( PPP000:ia_LiquefiedPetr PPP000:ia_MotorGasoline PPP000:ia_JetFuel PPP000:ia_DistillateFue PPP000:ia_ResidualFuel PPP000:ia_ResidualFuel( PPP000:ia_Average PPP000:nom_WorldOilPric PPP000:nom_ForeignLSLig PPP000:nom_Imported_Rea PPP000:nom_R_LiquefiedP PPP000:nom_R_Distillate PPP000:nom_C_Distillate PPP000:nom_C_ResidualFu PPP000:nom_I_LiquefiedP PPP000:nom_I_Distillate PPP000:nom_I_ResidualFu PPP000:nom_T_LiquefiedP PPP000:nom_T_Ethan(E85) PPP000:nom_T_EthanWhole PPP000:nom_T_MotorGasol PPP000:nom_T_JetFuel PPP000:nom_T_DieselFuel PPP000:nom_T_ResidualFu PPP000:nom_E_Distillate PPP000:nom_E_ResidualFu PPP000:nom_Avg_Liquefie PPP000:nom_Avg_MotorGas PPP000:nom_Avg_JetFuel PPP000:nom_Avg_Distilla PPP000:nom_Avg_Residual PPP000:nom_Avg_Average ref2025.d032025a 12. Petroleum and Other Liquids Prices (2024 dollars per gallon, unless otherwise noted) Sector and Fuel Crude Oil Prices (2024 dollars per barrel) Brent Spot West Texas Intermediate Spot West Texas Intermediate Spot (2025 adj.) WTI Y-o-Y, % Change Average Imported Cost 1/ Brent / West Texas Intermediate Spread Delivered Sector Product Prices Residential Propane Distillate Fuel Oil Commercial Distillate Fuel Oil Residual Fuel Oil Residual Fuel Oil (2024 dollars per barrel) Industrial 2/ Propane Distillate Fuel Oil Residual Fuel Oil Residual Fuel Oil (2024 dollars per barrel) Transportation Propane E85 3/ Ethanol Wholesale Price Motor Gasoline 4/ Jet Fuel 5/ Diesel Fuel (distillate fuel oil) 6/ Residual Fuel Oil Residual Fuel Oil (2024 dollars per barrel) Electric Power 7/ Distillate Fuel Oil Residual Fuel Oil Residual Fuel Oil (2024 dollars per barrel) Average Prices, All Sectors 8/ Propane Motor Gasoline 4/ Jet Fuel 5/ Distillate Fuel Oil Residual Fuel Oil Residual Fuel Oil (2024 dollars per barrel) Average Prices in Nominal Dollars Crude Oil Spot Prices (nominal dollars per barrel) Brent Spot West Texas Intermediate Spot Average Imported Cost 1/ Delivered Sector Product Prices Nominal (dollars to gallon) Residential Propane Distillate Fuel Oil Commercial Distillate Fuel Oil Residual Fuel Oil Industrial 2/ Propane Distillate Fuel Oil Residual Fuel Oil Transportation Propane E85 3/ Ethanol Wholesale Price Motor Gasoline 4/ Jet Fuel 5/ Diesel Fuel (distillate fuel oil) 6/ Residual Fuel Oil Electric Power 7/ Distillate Fuel Oil Residual Fuel Oil Average Prices, All Sectors 8/ Propane Motor Gasoline 4/ Jet Fuel 5/ Distillate Fuel Oil Residual Fuel Oil (dollars per barrel) Average Data source: 2024: U.S. Energy Information Administration (EIA), Short-Term Energy Outlook, December 2024 and EIA, AEO2025 Projections: EIA, AEO2025 National Energy Modeling System run ref2025.d032025a. 1/ Weighted average price delivered to U.S. refiners. 2/ Includes combined-heat-and-power plants that have a non-regulatory status and small on-site generating systems. 3/ E85 refers to a high-level ethanol-gasoline blend containing 51% to 83% ethanol, depending on geography and season. To address cold starting issues, the percentage of ethanol varies seasonally. The annual average ethanol content of 74% is used for these projections. 4/ Sales weighted-average price for all grades. Includes federal, state, and local taxes. 5/ Includes only kerosene type. 6/ Diesel fuel for on-road use. Includes federal and state taxes while excluding county and local taxes. 7/ Includes electricity-only and combined-heat-and-power plants that have a regulatory status. 8/ Weighted averages of end-use fuel prices are derived from the prices in each sector and the corresponding sectoral consumption. Report Scenario Datekey Release Date 2024 80.4889984130859 76.5080032348633 77.7661472338143 73.818000793457 3.98100113868713 2.43208456039429 3.59714579582214 3.60396003723144 1.00982367992401 42.4125938415527 1.15781152248383 3.58798432350159 1.17277860641479 49.2566986083984 1.60857915878296 2.74128460884094 1.65011358261108 3.44797825813294 2.38125467300415 3.75188660621643 2.00604557991028 84.2539138793945 3.59425115585327 2.60379433631897 109.359359741211 2.11340284347534 3.44850397109985 2.38125467300415 3.71458888053894 1.98962640762329 83.5643081665039 2.83057904243469 80.4889984130859 76.5080032348633 73.818000793457 2.43208456039429 3.59714579582214 3.60396003723144 1.00982367992401 1.15781152248383 3.58798432350159 1.17277860641479 1.60857915878296 2.74128460884094 1.65011358261108 3.44797825813294 2.38125467300415 3.75188660621643 2.00604557991028 3.59425115585327 2.60379433631897 2.11340284347534 3.44850397109985 2.38125467300415 3.71458888053894 83.5643081665039 2.83057904243469 Annual Energy Outlook 2025 ref2025 d032025a 2025 72.0958709716797 67.7275009155273 68.8412530099225 -0.114765801590478 65.1023559570313 4.36837720870972 2.34895443916321 3.38541030883789 3.39775443077087 1.11844205856323 46.9745635986328 1.15217792987824 3.38308262825012 1.32440447807312 55.6249847412109 1.62266385555267 2.75216507911682 1.65011358261108 3.25663256645203 2.21332550048828 3.51927852630615 1.77290952205658 74.4621963500977 3.38682985305786 2.0481014251709 86.0202560424805 2.09693145751953 3.26036882400513 2.21332550048828 3.48782849311829 1.76266062259674 74.0317459106445 2.6845862865448 73.5749893188477 69.1170043945313 66.4379959106445 2.39714574813843 3.45486569404602 3.46746277809143 1.14138805866241 1.17581605911255 3.45249009132385 1.35157597064972 1.6559544801712 2.80862855911255 1.68396735191345 3.32344579696655 2.25873422622681 3.59148025512695 1.80928254127502 3.45631432533264 2.09012031555176 2.13995218276977 3.32725882530212 2.25873422622681 3.55938506126404 75.5505828857422 2.73966336250305 April 2025 2026 81.4451904296875 79.1060943603516 80.4069629452289 0.168005511660855 77.5780639648438 2.33909559249878 2.36185002326965 3.37688755989075 3.229088306427 1.16726195812225 49.0249977111816 1.22498786449432 3.20994377136231 1.40573453903198 59.0408515930176 1.69387245178223 2.87222790718079 1.81477415561676 3.05474138259888 2.1746141910553 3.42930555343628 1.88668739795685 79.2408752441406 3.21547484397888 2.03503561019898 85.4714965820313 2.05024862289429 3.05992078781128 2.1746141910553 3.38309860229492 1.86491882801056 78.3265914916992 2.55867886543274 84.5197296142578 82.0923385620117 80.5066223144531 2.45100951194763 3.50436472892761 3.35098576545715 1.21132588386536 1.27123093605042 3.33111882209778 1.45880091190338 1.7578159570694 2.98065400123596 1.88328158855438 3.17005753517151 2.25670552253723 3.55876135826111 1.95790958404541 3.33685874938965 2.11185789108276 2.12764525413513 3.17543244361877 2.25670552253723 3.51081013679504 81.2834091186523 2.65526866912842 Reference 2027 80.3710174560547 78.2281875610352 79.5146193141499 -1.10978402664816E-02 76.6192932128906 2.14283180236816 2.34418535232544 3.47291922569275 3.16371273994446 1.31656169891357 55.2955932617188 1.20808267593384 3.14036870002747 1.5856831073761 66.5986862182617 1.67327511310577 2.83555364608765 1.84016716480255 2.99564576148987 2.22941279411316 3.43276524543762 1.87603414058685 78.7934341430664 3.15102958679199 2.13564896583557 89.6972579956055 2.0284857749939 3.00113463401794 2.22941279411316 3.38042664527893 1.87491166591644 78.7462844848633 2.52880430221558 84.7950897216797 82.534309387207 80.8368530273438 2.47322249412537 3.66408824920654 3.33786129951477 1.38903272151947 1.27458238601685 3.313232421875 1.67296802997589 1.76538169384003 2.99163842201233 1.94146037101746 3.1605429649353 2.35213232040405 3.62172389030457 1.97930157184601 3.32448005676269 2.2532069683075 2.14014506340027 3.1663339138031 2.35213232040405 3.56650424003601 83.080924987793 2.66800379753113 CPI (Dec 2024) CPI (Apr 2025) CPI Adj 2028 79.7570495605469 77.8192367553711 79.0989434734534 -5.22766560768126E-03 75.7934722900391 1.9378103017807 2.34486889839172 3.59323668479919 3.12221598625183 1.4779965877533 62.075855255127 1.21826636791229 3.09518194198608 1.7721940279007 74.4321441650391 1.68323600292206 2.786616563797 1.86632657051086 2.96342754364014 2.30942702293396 3.46486210823059 1.8661425113678 78.3779830932617 3.09656882286072 2.24523568153381 94.2998962402344 2.02922677993774 2.96846413612366 2.30942702293396 3.40315532684326 1.88452053070068 79.1498641967773 2.52155661582947 85.7362213134766 83.6531448364258 81.4755096435547 2.52065753936768 3.86261200904846 3.35628008842468 1.58879804611206 1.3095965385437 3.32721948623657 1.90505063533783 1.80942368507385 2.99552178382873 2.00624012947083 3.18558788299561 2.48255848884583 3.72461366653442 2.00604224205017 3.32871055603027 2.41355490684509 2.18135261535644 3.19100213050842 2.48255848884583 3.65828084945679 85.0835189819336 2.71059107780457 315.605 320.795 0.0164446063909 2029 79.5018768310547 77.6542892456055 78.9312834668145 -2.11962384421922E-03 75.6489944458008 1.84759187698364 2.36519479751587 3.71941304206848 3.08716917037964 1.64050030708313 68.9010162353516 1.24652421474457 3.05591511726379 1.96978080272675 82.7307891845703 1.70866906642914 2.69586777687073 1.66409683227539 2.927570104599 2.39260911941528 3.50088047981262 1.86370503902435 78.2756118774414 3.06366157531738 2.3488461971283 98.6515426635742 2.0483934879303 2.9315927028656 2.39260911941528 3.42987513542175 1.90068709850311 79.828857421875 2.51480722427368 86.9779052734375 84.9565734863281 82.7627105712891 2.58760786056519 4.06917142868042 3.37747383117676 1.79476618766785 1.3637421131134 3.34328079223633 2.15501093864441 1.86934518814087 2.94937610626221 1.82058155536652 3.20286679267883 2.61760020256042 3.83008861541748 2.03896021842957 3.35175561904907 2.56972193717957 2.24101591110229 3.20726752281189 2.61760020256042 3.75240635871887 87.3356323242188 2.75128936767578 2030 79.8005142211914 78.0275039672852 79.3106355576916 4.8061056936505E-03 75.8526000976563 1.77301168441773 2.40299367904663 3.8512704372406 3.05758023262024 1.81399822235107 76.1879272460938 1.28745341300964 3.02111387252808 2.1790623664856 91.5206146240234 1.74401867389679 2.69447159767151 1.66564750671387 2.92991590499878 2.4787802696228 3.54282093048096 1.86769318580627 78.443115234375 3.04728436470032 2.46101236343384 103.362518310547 2.08313083648682 2.93257021903992 2.4787802696228 3.46056079864502 1.92241668701172 80.7415008544922 2.52947974205017 88.9359512329102 86.9599685668945 84.5360794067383 2.67808437347412 4.2921576499939 3.40760731697083 2.02166199684143 1.43483901023865 3.36696600914002 2.42851781845093 1.94367110729218 3.00293040275574 1.85632812976837 3.26532816886902 2.7625470161438 3.948397397995 2.08150362968445 3.39613270759583 2.74274516105652 2.32160425186157 3.26828622817993 2.7625470161438 3.8567202091217 89.9846649169922 2.81905055046082 2031 80.3681411743164 78.2207260131836 79.5070350640808 2.47633252473961E-03 76.1012573242188 2.14742183685303 2.44712281227112 3.85940766334534 3.06397414207459 1.82461142539978 76.6336822509766 1.32661151885986 3.02791547775269 2.19402408599854 92.1490173339844 1.77630007266998 2.70690846443176 1.65814757347107 2.93193197250366 2.4945855140686 3.55161333084106 1.87797546386719 78.8749694824219 3.03803133964539 2.48013806343079 104.165794372559 2.12071108818054 2.93484663963318 2.4945855140686 3.4658899307251 1.93259048461914 81.1688003540039 2.52927994728088 91.4099884033203 88.9675369262695 86.5568695068359 2.78333520889282 4.38965463638306 3.48493599891663 2.07529640197754 1.50887584686279 3.44392323493958 2.49546313285828 2.02034735679627 3.07881283760071 1.88596177101135 3.33475255966186 2.83731865882873 4.03957271575928 2.1359920501709 3.45542907714844 2.82088613510132 2.41207718849182 3.33806777000427 2.83731865882873 3.94207167625427 92.3206481933594 2.87677979469299 2032 79.8358612060547 77.2063369750977 78.4759647975363 -1.29682897332731E-02 75.2489776611328 2.62952089309692 2.52254176139832 3.848557472229 3.04874873161316 1.82092499732971 76.4788513183594 1.40392732620239 3.01172804832459 2.19274854660034 92.0954360961914 1.84202539920807 2.68692111968994 1.62610685825348 2.9111123085022 2.48060083389282 3.53233218193054 1.87249040603638 78.6445999145508 3.11687016487122 2.46761083602905 103.639656066895 2.19117927551269 2.91427183151245 2.48060083389282 3.45033860206604 1.92662394046783 80.9182052612305 2.50831007957459 92.7233581542969 89.6693725585938 87.3960418701172 2.92974305152893 4.46981048583984 3.54089283943176 2.11486768722534 1.63055622577667 3.49789619445801 2.54671287536621 2.13937425613403 3.12065720558167 1.88860106468201 3.3810384273529 2.88103175163269 4.1025390625 2.17475724220276 3.62001061439514 2.86594462394714 2.54489040374756 3.38470816612244 2.88103175163269 4.0073094367981 93.9804229736328 2.91321396827698 2033 81.2712631225586 79.3589553833008 80.6639821681722 2.78813694904012E-02 77.3201675415039 1.91230952739716 2.6205780506134 3.89269137382507 3.09152007102966 1.85726368427277 78.0050735473633 1.4975289106369 3.05713653564453 2.23847913742065 94.0161285400391 1.91778492927551 2.66286730766296 1.55600798130035 2.89491963386536 2.5230348110199 3.58215975761414 1.90200519561768 79.8842239379883 3.16136789321899 2.50361967086792 105.15202331543 2.28246378898621 2.89837741851807 2.5230348110199 3.49300813674927 1.95720314979553 82.2025299072266 2.51028752326965 96.444694519043 94.1753540039063 91.7559204101563 3.1098427772522 4.61946105957031 3.66870999336243 2.20401692390442 1.7771190404892 3.62790727615356 2.65640568733215 2.27583742141724 3.16002750396729 1.84651637077331 3.4354043006897 2.99408793449402 4.25095272064209 2.25711154937744 3.75159859657288 2.97104811668396 2.7086021900177 3.43950748443604 2.99408793449402 4.1451563835144 97.5498352050781 2.97896075248718 2034 81.9990310668945 79.6462097167969 80.9559602861167 3.61968390471707E-03 77.6162567138672 2.35282063484192 2.70747804641724 3.91181135177612 3.10941004753113 1.87465345859528 78.7354431152344 1.56091105937958 3.07628273963928 2.25806307792664 94.8386459350586 1.96479105949402 2.66860866546631 1.57656002044678 2.90053796768189 2.54446983337402 3.60349225997925 1.91597473621368 80.4709396362305 3.17969870567322 2.52459979057312 106.033187866211 2.35330128669739 2.90434002876282 2.54446983337402 3.51034045219421 1.97153079509735 82.8042907714844 2.50493836402893 99.4629287719727 96.609016418457 94.146728515625 3.28410840034485 4.7449369430542 3.77164268493652 2.27391147613525 1.89334917068481 3.73145985603333 2.73897838592529 2.38324642181396 3.23696088790894 1.91233086585998 3.51828551292419 3.08638334274292 4.37095308303833 2.32403302192688 3.85690116882324 3.06228137016296 2.85450005531311 3.52289724349976 3.08638334274292 4.25796222686768 100.439697265625 3.03843259811401 2035 82.329231262207 80.0944900512695 81.4116124142425 5.62839507450054E-03 78.3089828491211 2.23473906517029 2.76960825920105 3.94498896598816 3.13988614082336 1.89611268043518 79.6367340087891 1.591712474823 3.11020493507385 2.28416609764099 95.9349746704102 1.98569667339325 2.6456184387207 1.58450639247894 2.87434411048889 2.57112836837769 3.64177799224854 1.9358788728714 81.3069152832031 3.2013750076294 2.55397152900696 107.266807556152 2.39605259895325 2.87847542762756 2.57112836837769 3.54317951202393 1.99204802513123 83.666015625 2.49181747436523 102.02848815918 99.259033203125 97.0463027954102 3.43230390548706 4.88892269134521 3.89117980003357 2.34980344772339 1.97256815433502 3.85439658164978 2.83070802688599 2.46082258224487 3.27864670753479 1.9636378288269 3.56210041046143 3.1863329410553 4.51316118240356 2.39908456802368 3.96738123893738 3.1650710105896 2.9693660736084 3.56722021102905 3.1863329410553 4.3909707069397 103.685127258301 3.08804512023926 2036 82.6127471923828 80.3663864135742 81.6879800052044 3.3946949675395E-03 78.7596054077148 2.24636197090149 2.80735898017883 3.95897507667542 3.15188574790955 1.90373456478119 79.9568557739258 1.60138618946075 3.12483429908752 2.29692316055298 96.4707717895508 1.99119520187378 2.64635539054871 1.51546704769134 2.87356424331665 2.58224415779114 3.65734553337097 1.94230926036835 81.5769882202148 3.20461273193359 2.56280946731567 107.638000488281 2.41620230674744 2.87808847427368 2.58224415779114 3.55776834487915 1.99805998802185 83.9185180664063 2.48445153236389 104.498641967773 101.657173156738 99.6247253417969 3.55108880996704 5.00779294967651 3.98688817024231 2.40807509422302 2.02562785148621 3.95267033576965 2.90542769432068 2.51870584487915 3.34743189811707 1.91694688796997 3.63483333587646 3.26633644104004 4.62625503540039 2.45686888694763 4.05358409881592 3.24175310134888 3.05630660057068 3.64055633544922 3.26633644104004 4.50029802322388 106.150337219238 3.1426362991333 2037 83.2178497314453 81.3478164672852 82.6855492898488 1.22119470279576E-02 79.234260559082 1.87002968788147 2.82898354530335 3.98480224609375 3.17574119567871 1.91306161880493 80.3485870361328 1.60369622707367 3.1501669883728 2.30959153175354 97.0028457641602 1.99218511581421 2.63526916503906 1.48581278324127 2.85986876487732 2.60672378540039 3.68459367752075 1.95184075832367 81.9773101806641 3.22172832489014 2.57598066329956 108.191192626953 2.42460203170776 2.86473751068115 2.60672378540039 3.58235359191894 2.00688242912292 84.2890625 2.47026705741882 107.453407287598 105.038764953613 102.309677124023 3.65286922454834 5.14529705047607 4.10061311721802 2.47020316123962 2.07074117660523 4.06759119033813 2.98221445083618 2.57236957550049 3.40273928642273 1.91852653026581 3.6927490234375 3.36588072776794 4.75765895843506 2.52027583122253 4.1599931716919 3.32618427276611 3.13071942329407 3.69903564453125 3.36588072776794 4.62564373016357 108.836585998535 3.18968343734741 2038 83.5139007568359 81.5835189819336 82.925127839576 2.89746578192701E-03 79.7444305419922 1.93038189411163 2.83741021156311 3.99872255325317 3.19083285331726 1.93230819702148 81.1569442749023 1.59881579875946 3.1647584438324 2.32928919792175 97.8301467895508 1.98786997795105 2.59261846542358 1.49006605148315 2.81523442268372 2.6364381313324 3.69585609436035 1.96650648117065 82.5932693481445 3.244056224823 2.59482645988464 108.982719421387 2.42305564880371 2.82053518295288 2.6364381313324 3.59330487251282 2.02101016044617 84.8824234008789 2.44020557403565 110.063522338867 107.519462585449 105.095718383789 3.73944187164307 5.26994323730469 4.20521974563599 2.54660201072693 2.10708999633789 4.17085647583008 3.06978583335877 2.61982703208923 3.41682934761047 1.96376812458038 3.71021628379822 3.47457957267761 4.87079334259033 2.59167194366455 4.27536344528198 3.41973924636841 3.19336128234863 3.71720218658447 3.47457957267761 4.73564052581787 111.867118835449 3.21596336364746 2039 84.1431655883789 82.0981063842773 83.448177429205 6.30749211072525E-03 80.3862075805664 2.04505920410156 2.84103608131409 4.01857757568359 3.2090916633606 1.9379209280014 81.3926773071289 1.59623026847839 3.18407416343689 2.3365683555603 98.135871887207 1.98601889610291 2.58265662193298 1.45023894309998 2.80059671401977 2.65290498733521 3.71665787696838 1.97182881832123 82.8168029785156 3.26101279258728 2.59802174568176 109.116912841797 2.42040324211121 2.80594706535339 2.65290498733521 3.61137104034424 2.02522873878479 85.0596084594727 2.42067360877991 113.164009094238 110.413612365723 108.111289978027 3.82090520858765 5.4045786857605 4.31590223312378 2.60630679130554 2.14676761627197 4.28225660324097 3.14244699478149 2.67099380493164 3.47341084480286 1.95042407512665 3.76651811599731 3.56788802146912 4.99852752685547 2.65190935134888 4.38573122024536 3.49407529830933 3.2551965713501 3.77371382713318 3.56788802146912 4.85692739486694 114.396537780762 3.25556015968323 2040 84.6552276611328 82.6969680786133 84.0568871683869 7.29446415649151E-03 81.0717926025391 1.95826303958893 2.85023236274719 4.05018472671509 3.23822259902954 1.94690811634064 81.7701416015625 1.60576009750366 3.21500205993652 2.3476026058197 98.5993041992188 1.99420130252838 2.57630372047424 1.41077578067779 2.78988027572632 2.68175220489502 3.74574470520019 1.98206865787506 83.2468795776367 3.28076457977295 2.61408805847168 109.791694641113 2.42668652534485 2.7952938079834 2.68175220489502 3.64200711250305 2.03472471237183 85.4584350585938 2.40906572341919 116.248115539551 113.559036254883 111.327362060547 3.91392421722412 5.561692237854 4.44671058654785 2.67348408699036 2.20502138137817 4.41482400894165 3.22371554374695 2.73842668533325 3.53776693344116 1.93726992607117 3.83104872703552 3.68256783485413 5.14363670349121 2.72176623344421 4.50512886047363 3.58965182304382 3.3323130607605 3.83848261833191 3.68256783485413 5.00118494033813 117.35107421875 3.30811619758606 2041 85.0312576293945 83.1302032470703 84.4972467186639 5.23882771669682E-03 81.5055770874023 1.9010546207428 2.86692404747009 4.08323764801025 3.27119588851929 1.95100605487824 81.942253112793 1.62400758266449 3.24756717681885 2.35460114479065 98.8932495117188 2.00886869430542 2.52429246902466 1.38755989074707 2.73588013648987 2.72349667549133 3.77435564994812 1.99220752716064 83.6727142333984 3.31429195404053 2.62285304069519 110.159828186035 2.44136905670166 2.74179863929748 2.72349667549133 3.67197418212891 2.04177689552307 85.7546310424805 2.38627147674561 119.257942199707 116.591674804688 114.313110351563 4.0209150314331 5.7268180847168 4.58791399002075 2.73632287979126 2.27770113945007 4.55477428436279 3.3023726940155 2.81747627258301 3.54036784172058 1.94607889652252 3.83712339401245 3.81975531578064 5.29360485076904 2.79410862922669 4.64835691452026 3.67860078811646 3.42406630516052 3.84542441368103 3.81975531578064 5.1500129699707 120.272483825684 3.34679102897644 2042 84.8682098388672 82.8615112304688 84.2241361676089 -3.23218284217333E-03 81.9823913574219 2.00669574737549 2.88276338577271 4.09925174713135 3.28530764579773 1.98685896396637 83.4480743408203 1.63691484928131 3.2622983455658 2.38903141021729 100.339317321777 2.01840806007385 2.4973726272583 1.36400246620178 2.70588850975037 2.74061918258667 3.78645706176758 2.01436042785644 84.603141784668 3.32589602470398 2.62012505531311 110.04524230957 2.45287752151489 2.71220898628235 2.74061918258667 3.68572688102722 2.06030297279358 86.5327224731445 2.36500763893127 121.625366210938 118.749549865723 117.489677429199 4.13131284713745 5.87467336654663 4.70820283889771 2.84738492965698 2.34587693214417 4.67522811889648 3.42374157905579 2.89259791374207 3.57900619506836 1.95476377010346 3.87783217430115 3.92760515213013 5.42640447616577 2.8867974281311 4.76637029647827 3.75492382049561 3.51523995399475 3.88689017295837 3.92760515213013 5.28204679489136 124.010795593262 3.3893129825592 2043 86.1562576293945 84.755012512207 86.1487753326261 2.28513969105843E-02 82.7939834594727 1.40124225616455 2.91737985610962 4.14301156997681 3.3292863368988 1.98385238647461 83.3218002319336 1.67631328105926 3.30793905258179 2.38926315307617 100.349052429199 2.05001091957092 2.49782156944275 1.35305225849152 2.7066867351532 2.79033184051514 3.83720111846924 2.02000260353088 84.8401107788086 3.37225794792175 2.61591553688049 109.868453979492 2.48644185066223 2.71341824531555 2.79033184051514 3.72964310646057 2.06217885017395 86.6115112304688 2.37547731399536 126.220344543457 124.167495727539 121.294555664063 4.27400970458984 6.06958055496216 4.87745952606201 2.90637683868408 2.45582675933838 4.8461856842041 3.50031042098999 3.00329995155335 3.65935015678406 1.98224401473999 3.96534109115601 4.08788251876831 5.62156295776367 2.95933747291565 4.94041395187378 3.832359790802 3.6426784992218 3.97520256042481 4.08788251876831 5.46398878097534 126.887306213379 3.48011374473572 2044 86.1391067504883 83.6849212646484 85.061086855699 -1.26256986559287E-02 82.9348526000977 2.454185962677 2.9453649520874 4.17160987854004 3.35693335533142 1.95987248420715 82.3146438598633 1.69661486148834 3.33613300323486 2.3640079498291 99.2883377075195 2.06409668922424 2.38260865211487 1.34290933609009 2.5845148563385 2.83049988746643 3.8680784702301 2.00744318962097 84.312614440918 3.38947463035584 2.57403421401977 108.109436035156 2.50738000869751 2.59160041809082 2.83049988746643 3.75631189346314 2.04481697082519 85.8823089599609 2.33999514579773 129.005889892578 125.330383300781 124.207046508789 4.41111373901367 6.24759435653687 5.0274977684021 2.93519496917725 2.54092836380005 4.99634599685669 3.54044699668884 3.09128618240356 3.56830430030823 2.01120257377625 3.87068819999695 4.23908662796021 5.7930121421814 3.00643920898438 5.07623291015625 3.85499167442322 3.75516748428345 3.88129997253418 4.23908662796021 5.6256251335144 128.621292114258 3.50448441505432 2045 86.6064682006836 84.6593856811523 86.0515759559743 1.16444444444444E-02 83.470817565918 1.94708013534546 2.97128891944885 4.18083763122559 3.36572027206421 1.96975708007813 82.7297973632813 1.71539831161499 3.34512948989868 2.37024426460266 99.5502624511719 2.07786798477173 2.38870525360107 1.33178842067719 2.58901500701904 2.84435057640076 3.88056898117065 1.99634599685669 83.8465347290039 3.40021276473999 2.50539231300354 105.22647857666 2.52640271186829 2.59641361236572 2.84435057640076 3.76376605033875 2.02969336509705 85.2471160888672 2.34874868392944 132.632431030273 129.650588989258 127.830375671387 4.55034446716309 6.40269327163696 5.15439176559448 3.0165605545044 2.62702608108521 5.12285804748535 3.62988185882568 3.18212580680847 3.65815377235413 2.03955125808716 3.96491551399231 4.35594654083252 5.9428505897522 3.05728006362915 5.20721483230591 3.83685278892517 3.86902904510498 3.97624611854553 4.35594654083252 5.76397371292114 130.550674438477 3.59696269035339 2046 87.0532379150391 85.0856094360352 86.4848087927406 5.03457178968997E-03 84.0520935058594 1.96763157844544 2.9987325668335 4.21574592590332 3.39980220794678 2.00887894630432 84.3729095458984 1.73781383037567 3.37986516952515 2.40826487541199 101.147125244141 2.09474658966065 2.34264898300171 1.31720864772797 2.53818297386169 2.88337206840515 3.91356444358826 2.02044081687927 84.858512878418 3.44335389137268 2.53692412376404 106.550811767578 2.54795289039612 2.54590320587158 2.88337206840515 3.79731369018555 2.05437994003296 86.2839584350586 2.33972811698914 136.331832885742 133.250381469727 131.631805419922 4.69623804092407 6.60217094421387 5.32434272766113 3.14605331420898 2.72154545783997 5.29311990737915 3.77152132987976 3.28052878379822 3.66876196861267 2.06284642219544 3.97498273849487 4.51557493209839 6.1289324760437 3.16416025161743 5.39254760742188 3.97301149368286 3.99028325080872 3.98707318305969 4.51557493209839 5.94687509536743 135.127075195313 3.66418790817261 2047 89.6370086669922 87.7604675292969 89.2036538744975 3.14372560882061E-02 86.4571990966797 1.87654185295105 3.04305171966553 4.28742408752441 3.47154331207275 2.08004260063171 87.3617935180664 1.78448760509491 3.45187473297119 2.47883296012878 104.110984802246 2.1308650970459 2.38002181053162 1.30416035652161 2.57627964019775 2.96672940254211 3.99921345710754 2.07399249076843 87.1076889038086 3.52230548858643 2.60432457923889 109.381629943848 2.58927965164185 2.58436894416809 2.96672940254211 3.86797022819519 2.10888719558716 88.5732650756836 2.37538623809815 143.579147338867 140.573333740234 138.485778808594 4.87431240081787 6.86752843856812 5.5606632232666 3.33177947998047 2.85836410522461 5.52915859222412 3.97055554389954 3.41318607330322 3.81228137016296 2.0889835357666 4.12664413452148 4.7520604133606 6.40587711334229 3.32208824157715 5.6419734954834 4.17156600952148 4.14746713638306 4.13960123062134 4.7520604133606 6.19565343856812 141.875259399414 3.80485606193542 2048 90.2388610839844 88.1036911010742 89.5525216228168 3.91091321001414E-03 87.0283203125 2.13516998291016 3.07340908050537 4.28862190246582 3.47207498550415 2.08225011825561 87.4545059204102 1.80189669132233 3.45262312889099 2.48237061500549 104.259567260742 2.1417715549469 2.38970565795898 1.29091393947601 2.58611798286438 2.97021269798279 4.00576400756836 2.080402135849 87.3768920898438 3.52354431152344 2.61792540550232 109.952857971191 2.60943651199341 2.59458661079407 2.97021269798279 3.86748600006104 2.11513686180115 88.8357467651367 2.36862993240356 147.839065551758 144.34098815918 142.579208374023 5.03519105911255 7.02608394622803 5.6883282661438 3.41136717796326 2.95206189155579 5.65646028518677 4.06688785552979 3.50888156890869 3.91507411003113 2.114914894104 4.23685789108276 4.86612319946289 6.56267595291138 3.40833973884583 5.77265119552612 4.28896856307983 4.27506113052368 4.25073194503784 4.86612319946289 6.33613348007202 145.540313720703 3.8805456161499 2049 91.1070022583008 88.6603851318359 90.1183702677946 0.006318623247272 87.6227340698242 2.44662284851074 3.09625744819641 4.28667688369751 3.47108697891235 2.09240579605102 87.8810424804688 1.8138279914856 3.45104122161865 2.49248886108398 104.684532165527 2.14985489845276 2.39750170707703 1.27916204929352 2.59331798553467 2.97645020484924 4.00153350830078 2.08789253234863 87.6914825439453 3.5283215045929 2.62968802452087 110.446899414063 2.62329292297363 2.60207772254944 2.97645020484924 3.8633770942688 2.12261414527893 89.1497955322266 2.36627674102783 152.631973266602 148.533142089844 146.794769287109 5.18717384338379 7.18148946762085 5.8151273727417 3.50541687011719 3.03871440887451 5.78154468536377 4.17567825317383 3.60166168212891 4.01654529571533 2.14298582077026 4.34459733963013 4.98646068572998 6.70378732681274 3.49785590171814 5.91101264953613 4.40552806854248 4.39481449127197 4.35927248001099 4.98646068572998 6.4723334312439 149.353057861328 3.96423387527466 2050 91.4553298950195 89.265998840332 90.7339430553518 6.83071371273157E-03 88.1888275146484 2.18933320045471 3.11204624176025 4.30285787582397 3.4857988357544 2.13905382156372 89.8402633666992 1.82052409648895 3.46677207946777 2.53831171989441 106.609092712402 2.1542809009552 2.41739511489868 1.2770984172821 2.61318445205689 2.99353885650635 4.0092921257019 2.12184453010559 89.1174774169922 3.5402181148529 2.67193937301636 112.221450805664 2.63134527206421 2.62224721908569 2.99353885650635 3.87866997718811 2.15708947181702 90.5977630615234 2.3759343624115 156.648162841797 152.898193359375 151.053176879883 5.33043146133423 7.37009859085083 5.97060871124268 3.66385269165039 3.11826276779175 5.93801879882813 4.34771680831909 3.68993425369263 4.14060592651367 2.18746280670166 4.47596168518066 5.1274471282959 6.86726808547974 3.63437581062317 6.06382036209106 4.57659959793091 4.50706815719604 4.49148464202881 5.1274471282959 6.64353322982788 155.179290771484 4.06959056854248 Avg Annual Change 2024-2050 4.92478500094751E-03 5.94937033428922E-03 6.86490493163827E-03 -2.27351222035945E-02 9.52708617808828E-03 6.91374138534573E-03 -1.28133270393049E-03 2.92895052400237E-02 2.92895071683539E-02 0.017559808191685 -1.3209210641546E-03 3.01424078993415E-02 3.01424103778918E-02 1.12981823788916E-02 -4.82432860348914E-03 -9.80749284746263E-03 -1.06056086658542E-02 8.83994856874049E-03 2.55540912215002E-03 2.16080659652218E-03 2.16080990825507E-03 -5.82419877339868E-04 9.94140921535935E-04 9.94140779354336E-04 8.46624748613323E-03 -1.04796570277651E-02 8.83994856874049E-03 1.66385568075045E-03 3.1130262044412E-03 3.1130288784329E-03 -6.71162665008329E-03 2.59416129748316E-02 2.69876262894206E-02 2.79223091344045E-02 3.06401692654821E-02 2.79721670421749E-02 1.96057019774738E-02 5.08158935073246E-02 3.88408822159516E-02 1.95652846083585E-02 5.16866337462203E-02 3.24483035825938E-02 1.59886057118581E-02 1.09012290350934E-02 1.00864201142439E-02 0.029938658153273 2.35226857743542E-02 2.31198281544467E-02 2.03192333132238E-02 2.19287670728312E-02 2.95571412515199E-02 0.010215005061196 0.029938658153273 0.022612484933368 0.024091966337032 0.014061838851553 CSD000:ba_Appalachia CSD000:ba_Interior CSD000:ba_West CSD000:ca_EastoftheMiss CSD000:ca_WestoftheMiss CSD000:ca_Total CSD000:ca_WasteCoalSup CSD000:da_Imports CSD000:da_Exports CSD000:da_SteamCoalExp CSD000:da_MetallurgicalCoalExp CSD000:da_Total CSD000:ea_TotalSupply CSD000:fa_Residentialan CSD000:fa_CokePlants CSD000:fa_Industrial CSD000:fa_ElectricPower CSD000:fa_TotalCoalUse CSD000:ga_Discrepancyan CSD000:ha_dolpershorton CSD000:ha_dolpermillBtu CSD000:real_comm_inst CSD000:ia_CokePlants CSD000:ia_Industrial CSD000:ia_dolpershorton CSD000:ja_dolpermillBtu CSD000:ja_Average CSD000:ja_Exports CSD000:nom_dolpershortn CSD000:nom_dolpermilBtu CSD000:nom_comm_inst CSD000:nom_CokePlants CSD000:nom_Industrial CSD000:nom_dollpershort CSD000:nom_dollmillionB CSD000:nom_Average CSD000:nom_Exports ref2025.d032025a 15. Coal Supply, Disposition, and Prices (million short tons, unless otherwise noted) Supply, Disposition, and Prices Production 1/ Appalachia Interior West East of the Mississippi West of the Mississippi Total Waste Coal Supplied 2/ Net Imports Imports 3/ Exports Steam Coal Metallurgical Coal Total Total Supply 4/ Consumption by Sector Commercial and Institutional Coke Plants Other Industrial 5/ Electric Power 6/ Total Discrepancy and Stock Change 7/ Average Minemouth Price 8/ (2024 dollars per short ton) (2024 dollars per MMBtu) Delivered Prices 9/ (2024 dollars per short ton) Commercial and Institutional Coke Plants Other Industrial 5/ Electric Power 6/ (2024 dollars per short ton) ($2025 adj dollars per short ton) Y-o-Y, % Change (2024 dollars per MMBtu) Average Exports 10/ Average Minemouth Price 8/ (nominal dollars per short ton) (nominal dollars per MMBtu) Delivered Prices 9/ (nominal dollars per short ton) Commercial and Institutional Coke Plants Other Industrial 5/ Electric Power 6/ (nominal dollars per short ton) (nominal dollars per MMBtu) Average Exports 10/ Data source: 2024: U.S. Energy Information Administration (EIA), Short-Term Energy Outlook, December 2024 and EIA, AEO2025 National Energy Modeling System run ref2025.d032025a. Projections: EIA, AEO2025 National Energy Modeling System run ref2025.d032025a. Note: Totals may not equal sum of components due to independent rounding. 1/ Includes anthracite, bituminous coal, subbituminous coal, and lignite. 2/ Includes waste coal consumed by the electric power and industrial sectors. Waste coal supplied is counted as a supply-side item to balance the same amount of waste coal included in the consumption data. 3/ Excludes imports to Puerto Rico and the U.S. Virgin Islands. 4/ Production plus waste coal supplied plus net imports. 5/ Includes consumption for combined-heat-and-power plants that have a non-regulatory status, and small on-site generating systems. 6/ Includes all electricity-only and combined-heat-and-power plants that have a regulatory status. 7/ Balancing item: the sum of production, net imports, and waste coal supplied minus total consumption. 8/ Includes reported prices for both open market and captive mines. Prices weighted by production, which differs from average minemouth prices published in EIA data reports where it is weighted by reported sales. 9/ Prices weighted by consumption; weighted average excludes commercial and institutional prices and export free-alongside-ship prices. 10/ Free-alongside-ship price at U.S. port of exit. - - = Not applicable Btu = British thermal unit Report Scenario Datekey Release Date 2024 153.622711181641 109.041656494141 236.267227172852 262.664367675781 236.267227172852 498.931579589844 6.78101873397827 1.26989996433258 107.512351989746 53.7080116271973 53.8043327331543 -106.242454528809 399.470123291016 0.520020127296448 15.2439994812012 20.677001953125 351.367401123047 387.808410644531 11.6617126464844 54.3001556396484 2.57167053222656 93.6480255126953 222.197830200195 78.0824737548828 47.9745826721191 48.7635058009298 2.48938775062561 56.2759203347677 166.665939331055 54.3001556396484 2.57167053222656 93.6480255126953 222.197830200195 78.0824737548828 47.9745826721191 2.48938775062561 56.2759203347677 166.665939331055 Annual Energy Outlook 2025 ref2025 d032025a 2025 141.20166015625 104.365386962891 236.186096191406 245.567031860352 236.186111450195 481.753143310547 7.07938575744629 1.63301992416382 104.433250427246 51.7812767028809 52.6519737243652 -102.800231933594 386.032287597656 0.677142083644867 15.2270002365112 20.9369983673096 353.569488525391 390.41064453125 -4.37835693359375 52.2435417175293 2.48270916938782 90.7929077148438 218.293579101563 79.17919921875 46.9139823913574 47.6854643660129 -2.21075457395922E-02 2.42959642410278 55.192451850938 164.22639465332 53.315372467041 2.53364443778992 92.6556243896484 222.772094726563 80.8036422729492 47.8764724731445 2.47944211959839 56.3247831958521 167.595672607422 April 2025 2026 130.742736816406 106.888816833496 199.179351806641 237.631561279297 199.17936706543 436.810913085938 7.56086826324463 1.43440186977386 108.005752563477 55.0019950866699 53.0037574768066 -106.571350097656 337.800445556641 0.695511281490326 15.4797677993774 16.712776184082 306.712005615234 339.600067138672 -1.79962158203125 53.9933776855469 2.55593299865723 90.256103515625 216.68537902832 79.1855697631836 45.2656364440918 46.0100120184485 -3.51354940093357E-02 2.37598204612732 54.8407949181933 161.733795166016 56.0316200256348 2.652419090271 93.6632537841797 224.865219116211 82.1748123168945 46.9744071960449 2.46567511558533 56.9110274744418 167.839218139648 Reference 2027 118.001342773438 108.334602355957 160.238388061523 226.335952758789 160.238403320313 386.574371337891 7.57741641998291 1.4529789686203 110.000129699707 55.9988594055176 54.0012626647949 -108.547149658203 285.604644775391 0.717816054821014 15.0941619873047 16.9331531524658 254.352478027344 287.097595214844 -1.49295043945313 58.0035400390625 2.71532130241394 89.1985473632813 215.49787902832 78.7368392944336 44.1974868774414 44.9242971526079 -0.023597361057094 2.32951235771179 55.353269298626 160.876724243164 61.1963844299316 2.86478781700134 94.1085433959961 227.360092163086 83.0709609985352 46.6303634643555 2.4577419757843 58.4002254987944 169.732284545898 2028 121.914123535156 105.368759155273 151.391220092773 227.28288269043 151.391220092773 378.674102783203 7.5104660987854 1.46952092647552 112.010551452637 57.0080947875977 55.0024604797363 -110.541030883789 275.643524169922 0.761573314666748 14.4951658248901 17.1545143127441 244.639190673828 277.050445556641 -1.40692138671875 58.6843452453613 2.72651100158691 87.6535263061523 214.593322753906 78.1880798339844 42.0241470336914 42.7152175905738 -4.91733805991417E-02 2.23518109321594 53.4175337777836 162.64875793457 63.0837554931641 2.93091034889221 94.2246780395508 230.680816650391 84.0496368408203 45.1745834350586 2.40274667739868 57.4221039545701 174.842102050781 CPI (Dec 2024) CPI (Apr 2025) CPI Adj 2029 104.179992675781 105.645492553711 149.327987670898 209.825500488281 149.327987670898 359.153472900391 7.46249866485596 1.4763491153717 111.890632629395 55.8886985778809 56.0019378662109 -110.414283752441 256.201690673828 0.742166996002197 14.0002708435059 17.24582862854 224.552551269531 256.540832519531 -0.339141845703125 59.380054473877 2.77958631515503 87.9326171875 214.342315673828 77.7751846313477 41.4168510437012 42.0979348570654 -1.44511199597547E-02 2.20656943321228 53.4326945429841 159.634811401367 64.9639129638672 3.04096722602844 96.2014389038086 234.498184204102 85.0888366699219 45.3115196228027 2.41406607627869 58.4572841894738 174.646194458008 315.605 320.795 0.0164446063909 2030 99.0126113891602 105.673042297363 105.54320526123 204.685638427734 105.54320526123 310.228851318359 7.43518972396851 1.4856504201889 109.885215759277 52.879524230957 57.0056915283203 -108.399566650391 209.26448059082 0.753457963466644 13.7130908966065 17.3479480743408 181.015151977539 212.829650878906 -3.56517028808594 65.5422286987305 2.99790048599243 87.4247589111328 214.237854003906 77.2586822509766 42.733814239502 43.4365549942524 3.17977625679746E-02 2.23902201652527 56.7565660867461 160.85954284668 73.0453948974609 3.3410952091217 97.4330062866211 238.763473510742 86.1031341552734 47.6259117126465 2.49534153938294 63.253967474633 179.274490356445 2031 93.5500869750977 99.8240661621094 101.068710327148 193.374145507813 101.068717956543 294.44287109375 7.38376045227051 1.14024436473846 110.790328979492 52.7895393371582 58.0007934570313 -109.650085449219 192.176544189453 0.802097856998444 13.4961633682251 17.4079360961914 164.186187744141 195.892379760742 -3.71583557128906 66.7151870727539 3.04779839515686 85.0622863769531 214.309188842773 77.0203399658203 41.830078125 42.5179572950662 -2.11480330175294E-02 2.19799757003784 57.0173666253395 160.009460449219 75.8812408447266 3.4665379524231 96.7490692138672 243.753311157227 87.6022338867188 47.5771484375 2.49998235702515 64.8510304195449 181.993286132813 2032 96.0850219726563 16.3773536682129 58.5407905578613 112.462387084961 58.5407943725586 171.003158569336 9.23361070454121E-03 1.50594639778137 109.814331054688 50.0582275390625 59.7561111450195 -108.308387756348 62.7040061950684 0.833657801151276 13.289755821228 17.6049652099609 31.6897029876709 63.418083190918 -0.714076995849609 98.7079162597656 4.1593074798584 83.6673278808594 214.86555480957 75.882080078125 36.9406661987305 37.5481409141862 -0.116887468191157 1.97795045375824 85.6506644973962 163.908462524414 114.64183807373 4.83072328567505 97.1733169555664 249.550231933594 88.1313400268555 42.9038124084473 2.29724097251892 99.4768193766589 190.367385864258 2033 95.8187866210938 16.3180961608887 58.6209411621094 112.13688659668 58.6209373474121 170.757827758789 9.23361070454121E-03 1.50813806056976 109.930015563965 49.9261817932129 60.0038375854492 -108.421875 62.3451881408691 0.835368990898132 12.8745698928833 17.6345653533936 31.143705368042 62.4882125854492 -0.143024444580078 98.7363510131836 4.16085147857666 83.4410171508789 214.748138427734 75.6480712890625 36.5623245239258 37.1635775594581 -1.02418747071133E-02 1.95912861824036 84.9312349307131 163.851928710938 117.170524597168 4.93768692016602 99.0195388793945 254.841842651367 89.7716445922852 43.3885498046875 2.32489991188049 100.787986224092 194.443267822266 2034 106.91845703125 15.940336227417 43.9390525817871 122.85880279541 43.9390525817871 166.7978515625 9.23361070454121E-03 1.50348889827728 108.612693786621 49.3992195129395 59.2134819030762 -107.10920715332 59.6978797912598 0.87484747171402 12.5970602035522 17.5735034942627 28.7556858062744 59.8010940551758 -0.103214263916016 103.521141052246 4.24793386459351 82.4190979003906 213.721572875977 75.4286651611328 36.7438621520996 37.3481005024724 4.96515554023473E-03 1.9662880897522 86.0604423593997 166.462326049805 125.568756103516 5.1526460647583 99.9724655151367 259.239349365234 91.4932327270508 44.5694580078125 2.38506197929382 104.389331683376 201.914962768555 2035 112.480773925781 15.5447301864624 38.7387886047363 128.025497436523 38.7387886047363 166.764282226563 9.23361070454121E-03 1.49027490615845 110.095359802246 49.5343322753906 60.56103515625 -108.605087280273 58.1684303283691 0.907888174057007 12.3051595687866 17.4333992004395 27.534107208252 58.1805534362793 -1.21231079101563E-02 105.271926879883 4.26718378067017 81.5941925048828 214.33479309082 74.8641052246094 36.5630798339844 37.1643452902933 -4.92006848291792E-03 1.95896303653717 86.3410392222789 168.51496887207 130.460784912109 5.28821039199829 101.117576599121 265.619567871094 92.7771530151367 45.3116798400879 2.4276921749115 107.000220584791 208.836242675781 2036 110.580139160156 15.3533906936646 36.7237663269043 125.933532714844 36.7237663269043 162.657287597656 9.23361070454121E-03 1.47056555747986 108.972900390625 48.0707931518555 60.9021110534668 -107.502334594727 55.1641883850098 0.912125051021576 12.0099954605103 17.2143974304199 25.0835590362549 55.2200775146484 -5.58891296386719E-02 107.156845092773 4.32912445068359 81.5717163085938 214.295532226563 74.9790573120117 36.7910842895508 37.3960991893869 6.23592040390637E-03 1.9697767496109 88.0415809108169 169.726013183594 135.544998168945 5.47600269317627 103.181816101074 271.067047119141 94.8426284790039 46.5378379821777 2.49161314964294 111.3656953559 214.690093994141 2037 112.615394592285 14.3525867462158 35.0688819885254 126.967979431152 35.0688781738281 162.036849975586 9.23361070454121E-03 1.44917297363281 111.591499328613 50.4455299377441 61.1459693908691 -110.14232635498 51.9037590026855 0.909863948822021 11.8294200897217 16.9421215057373 22.5689029693604 52.2503089904785 -0.346549987792969 107.886421203613 4.34212350845337 81.7015762329102 214.215805053711 75.1401748657227 35.9112434387207 36.5017897020783 -2.39145126549035E-02 1.94087517261505 89.7965467729048 168.530334472656 139.306213378906 5.60668134689331 105.495552062988 276.601928710938 97.0232696533203 46.369686126709 2.50611662864685 115.948018669044 217.611480712891 2038 106.728897094727 13.96852684021 40.0349311828613 120.697418212891 40.0349349975586 160.732345581055 9.23361070454121E-03 1.42299282550812 113.002731323242 51.367073059082 61.6356620788574 -111.579734802246 49.1618461608887 0.903740227222443 11.6364393234253 16.6757125854492 20.3527069091797 49.5685997009277 -0.406753540039063 107.170951843262 4.36014890670776 81.7847900390625 214.138229370117 75.3626174926758 36.1898193359375 36.7849466702748 7.75734479069667E-03 1.9522602558136 91.9736478255735 166.443771362305 141.241317749023 5.74626970291138 107.784721374512 282.214202880859 99.3208999633789 47.6948051452637 2.57289671897888 121.212686902061 219.357345581055 2039 112.944671630859 12.5752878189087 26.1689796447754 125.519966125488 26.1689796447754 151.688949584961 0 1.411017537117 114.239822387695 52.9689483642578 61.2708740234375 -112.828804016113 38.8601455688477 0.931440055370331 11.4025659561157 16.4514904022217 10.0681009292603 38.8535957336426 6.54983520507813E-03 113.232299804688 4.47879886627197 81.147346496582 213.518768310547 75.1038818359375 38.9753265380859 39.6162604419616 0.076969359152958 2.06668162345886 106.508136650945 166.296798706055 152.285934448242 6.02352952957153 109.13493347168 287.161071777344 101.007095336914 52.417854309082 2.77947688102722 143.242627515286 223.652297973633 2040 115.60277557373 12.5396156311035 23.9899139404297 128.142395019531 23.9899120330811 152.132293701172 0 1.39780461788177 115.000259399414 53.2269401550293 61.7733192443848 -113.60245513916 38.5298385620117 0.938191294670105 11.2224931716919 16.2670478820801 10.09397315979 38.5217056274414 8.1329345703125E-03 113.839820861816 4.48010635375977 80.876579284668 213.454940795898 75.0106048583984 38.9363327026367 39.5766253682367 -1.00047488790414E-03 2.06467127799988 106.033660668635 166.960784912109 156.324234008789 6.15205812454224 111.059295654297 293.115203857422 103.004173278809 53.4671669006348 2.83519577980042 145.604865641135 229.269668579102 2041 117.237808227539 12.5048875808716 19.6419296264648 129.742691040039 19.6419296264648 149.384613037109 0 1.38430941104889 112.615631103516 52.01953125 60.5960922241211 -111.231323242188 38.1532897949219 0.927371919155121 11.0102777481079 16.096227645874 10.1175231933594 38.1514015197754 1.88827514648438E-03 114.78426361084 4.4813756942749 81.046142578125 212.676239013672 75.0757675170898 38.9316024780273 39.5718173569455 -1.21486135982765E-04 2.06448936462402 105.346390738113 167.811248779297 160.987091064453 6.28521394729614 113.668739318848 298.282440185547 105.295181274414 54.6023101806641 2.89548540115356 147.750301074835 235.358444213867 2042 117.739303588867 12.3194313049316 19.3674163818359 130.058731079102 19.3674163818359 149.426162719727 0 1.37028336524963 113.201080322266 52.7676277160645 60.4334487915039 -111.830795288086 37.5953674316406 0.923917412757874 10.7655076980591 15.914008140564 9.99354457855225 37.5969772338867 -1.60980224609375E-03 114.676986694336 4.47634553909302 81.0605316162109 212.571792602539 75.0427932739258 38.8274765014648 39.4659790696834 -2.67458747995969E-03 2.06574249267578 104.944407552799 167.458511352539 164.344589233398 6.41508960723877 116.168548583984 304.638488769531 107.544479370117 55.6439933776855 2.96043348312378 150.396740468191 239.986251831055 2043 118.468841552734 12.2756853103638 19.3451633453369 130.744537353516 19.3451633453369 150.089691162109 0 1.35717761516571 114.225662231445 54.4442558288574 59.7814025878906 -112.86848449707 37.2212066650391 0.922193348407745 10.573037147522 15.7304239273071 10.0019435882568 37.2276000976563 -6.3934326171875E-03 114.230339050293 4.46525049209595 81.1545028686523 212.354019165039 75.1907577514648 38.9465789794922 39.587040141082 3.06747923787574E-03 2.0719633102417 104.556592040081 166.636703491211 167.349349975586 6.54166603088379 118.892692565918 311.102142333984 110.155708312988 57.0573844909668 3.03546047210693 153.177142296479 244.125534057617 2044 119.184143066406 11.3469285964966 17.6837825775146 130.53108215332 17.6837844848633 148.214859008789 0 1.34212899208069 115.282135009766 55.4649887084961 59.8171424865723 -113.940002441406 34.2748565673828 0.913952827453613 10.3351030349731 15.5391607284546 7.50793266296387 34.2961502075195 -2.12936401367188E-02 116.076438903809 4.5219030380249 81.3777542114258 212.441055297852 75.297119140625 38.0859069824219 38.7122147317882 -2.20987829899901E-02 2.04906749725342 108.641231978181 166.705947875977 173.841415405273 6.77220964431763 121.875068664551 318.161468505859 112.768424987793 57.0391998291016 3.06877756118774 162.706101001215 249.666473388672 2045 120.973411560059 11.0951795578003 18.499080657959 132.068588256836 18.499080657959 150.567657470703 0 1.32822501659393 118.471801757813 58.0051879882813 60.4666175842285 -117.143577575684 33.4240798950195 0.91232705116272 10.0891351699829 15.347393989563 7.09828233718872 33.4471397399902 -2.30598449707031E-02 116.163787841797 4.53394412994385 81.4100646972656 212.769073486328 75.3554229736328 37.6590881347656 38.2783770161821 -1.12067397489905E-02 2.05740213394165 108.970529668009 166.301071166992 177.89762878418 6.94345378875732 124.674461364746 325.842620849609 115.402153015137 57.6725540161133 3.15078353881836 166.881599315632 254.679763793945 2046 121.161056518555 11.4270868301392 13.0443744659424 132.588150024414 13.0443744659424 145.632522583008 0 1.31552517414093 119.244766235352 58.7677574157715 60.4770126342773 -117.929237365723 27.7032852172852 0.896826505661011 9.78403377532959 15.1690397262573 1.89430379867554 27.7442035675049 -4.09183502197266E-02 119.802024841309 4.62373208999634 81.9431838989258 212.797256469727 75.644172668457 39.1958923339844 39.8404533555569 4.08083221165421E-02 1.87900996208191 121.726422056116 166.353439331055 187.618850708008 7.24110794067383 128.329116821289 333.256286621094 118.464385986328 61.383674621582 2.94266891479492 190.632610277042 260.521820068359 2047 120.765380859375 10.8149795532227 15.570686340332 131.580352783203 15.5706853866577 147.151031494141 0 1.3041365146637 121.611534118652 61.1565170288086 60.455020904541 -120.307395935059 26.843635559082 0.896257817745209 9.53647613525391 14.9905195236206 1.41560161113739 26.8388538360596 4.78172302246094E-03 119.508964538574 4.63348436355591 82.017219543457 212.667114257813 75.7407913208008 45.7641983032227 46.5167725311143 0.167576385639352 2.35156869888306 123.022430006137 165.771041870117 191.42756652832 7.42184209823608 131.373886108398 340.646820068359 121.320404052734 73.3043670654297 3.76670551300049 197.05538638648 265.529449462891 2048 120.630081176758 10.4009923934937 16.9267692565918 131.03108215332 16.9267692565918 147.957855224609 0 1.29261314868927 122.745719909668 62.3022842407227 60.4434280395508 -121.453109741211 26.5047454833984 0.89652681350708 9.32872104644775 14.814398765564 1.45269083976746 26.4923362731934 1.24092102050781E-02 119.205543518066 4.63414764404297 82.0052108764648 212.528106689453 75.7644805908203 45.004264831543 45.7443422526095 -1.66054142726276E-02 2.35431623458862 122.44740776009 165.704055786133 195.29541015625 7.59216165542603 134.349792480469 348.1865234375 124.125556945801 73.7308502197266 3.85709547996521 200.606579568539 271.474304199219 2049 120.490463256836 10.2051763534546 18.4236640930176 130.69563293457 18.4236640930176 149.11930847168 0 1.27975261211395 124.28963470459 63.1952667236328 61.0943717956543 -123.009880065918 26.1094284057617 0.898745656013489 9.09516620635986 14.6373834609985 1.46804988384247 26.09934425354 1.00841522216797E-02 118.358177185059 4.61147975921631 81.8771286010742 212.506622314453 75.7379989624023 44.9431304931641 45.682202584099 -1.35841211066869E-03 2.35328054428101 121.878737497817 165.227752685547 198.285995483398 7.7256326675415 137.169128417969 356.013305664063 126.884216308594 75.2934341430664 3.9424614906311 204.184001171079 276.806793212891 2050 120.066909790039 10.1567115783691 16.5470695495606 130.223617553711 16.5470714569092 146.770706176758 0 1.26450943946838 122.37850189209 61.2405967712402 61.1379089355469 -121.113990783691 25.6567153930664 0.898397445678711 8.8776798248291 14.433027267456 1.43444788455963 25.6435527801514 1.31626129150391E-02 119.017112731934 4.61737203598022 81.8568725585938 212.304443359375 75.8759613037109 46.4059104919434 47.1690374241947 3.25473544616966E-02 2.36076354980469 121.667910865617 165.55940246582 203.857025146484 7.90881061553955 140.207565307617 363.643127441406 129.963226318359 79.4858093261719 4.0436053276062 208.3974230234 283.576446533203 Avg Annual Change 2024-2050 -9.43408255109024E-03 -0.087248965540244 -9.72050132450619E-02 -2.66246798603617E-02 -9.72050092426225E-02 -4.59712191601884E-02 -- -1.63597272087701E-04 4.99369534675642E-03 5.06076775318065E-03 4.92663912105584E-03 5.05150008405431E-03 -0.100206291800316 0.021251315687874 -2.05793598519242E-02 -1.37318812025413E-02 -0.190694606079773 -9.91981527599531E-02 -0.229739399990021 3.06424185575869E-02 2.27656559079235E-02 -5.16243931711169E-03 -1.75026703023162E-03 -1.10191955735617E-03 -1.27781791694581E-03 -2.03836939752589E-03 3.00990310195397E-02 -2.56174413531429E-04 5.21970995579397E-02 4.41556069285438E-02 1.56434274739519E-02 1.91269614054697E-02 0.019788866254586 1.96092914287349E-02 1.88328308760457E-02 5.16423497012837E-02 2.06523017091853E-02 NGS000:ba_DryGasProduct NGS000:ba_SupplementalN NGS000:ba_RngProd NGS000:ca_NetImports NGS000:ca_PipelineImp NGS000:ca_LiquefiedNatu NGS000:da_TotalSupply NGS000:ea_Total NGS000:ea_Residential NGS000:ea_Commercial NGS000:Total_industrial NGS000:ea_Industrial NGS000:ea_LeaseandPlant NGS000:fa_Gas2LiqLiqPrd NGS000:Total_transport NGS000:ea_Transportatio NGS000:ea_PipelineFuel NGS000:ea_liquefactexp NGS000:ea_ElectricPower NGS000:ga_Discrepancy NGS000:ia_HenryHub NGS000:ja_Residential NGS000:ja_Commercial NGS000:ja_Industrial NGS000:ja_Transportatio NGS000:ja_ElectricPower NGS000:ja_Average NGS000:nom_HenryHub NGS000:nom_Residential NGS000:nom_Commercial NGS000:nom_Industrial NGS000:nom_Transportati NGS000:nom_ElectricPowr NGS000:nom_Average ref2025.d032025a 13. Natural Gas Supply, Disposition, and Prices (trillion cubic feet, unless otherwise noted) Supply, Disposition, and Prices Production Dry Gas Production 1/ Supplemental Natural Gas 2/ Renewable Natural Gas 3/ Net Imports Pipeline 4/ Liquefied Natural Gas Total Supply Consumption by Sector Residential Commercial Industrial 5/ Other Industrial 5/ 6/ Lease and Plant Fuel 7/ Hydrogen Production Natural Gas Feedstock 8/ Transportation Motor Vehicles, Trains, and Ships Pipeline and Distribution Fuel Fuel Used to Liquefy Gas for Export 9/ Electric Power 10/ Discrepancy 11/ Natural Gas Prices Natural Gas Spot Price at Henry Hub (2024 dollars per MMBtu) $2025 adj. Henry Hub Y-o-Y, % Change Delivered Prices (2024 dollars per thousand cubic feet) Residential Commercial Industrial 12/ Transportation 13/ Electric Power 10/ Average 14/ Natural Gas Spot Price at Henry Hub (nominal dollars per MMBtu) Delivered Prices (nominal dollars per thousand cubic feet) Residential Commercial Industrial 12/ Transportation 13/ Electric Power 10/ Average 14/ Data source: 2024: U.S. Energy Information Administration (EIA), Short-Term Energy Outlook, December 2024 and EIA, AEO2025 National Energy Modeling System run ref2025.d032025a. Projections: EIA, AEO2025 National Energy Modeling System run ref2025.d032025a. Note: Totals may not equal sum of components due to independent rounding. 1/ Dry production minus extraction losses. 2/ Synthetic natural gas, propane air, coke oven gas, refinery gas, biomass gas, air injected for Btu stabilization, and manufactured gas commingled and distributed with natural gas. 3/ Includes biogas that has been further processed into pipeline-quality gas and is fully interchangable with conventional natural gas. 4/ Natural gas imported to and exported from Canada and Mexico. 5/ Includes energy for combined-heat-and-power plants that have a non-regulatory status and small on-site generating systems. 6/ Includes natural gas used for heat and power in production of hydrogen. Natural gas feedstock for hydrogen production is not included here and is a separate volume given that is converted to hydrogen, which is included in the industrial sector energy balance. 7/ Represents natural gas used in well, field, and lease operations and in natural gas processing plant machinery. 8/ Includes hydrogen gas used for feedstock in reformers to produce hydrogen gas. This includes feedstock attributed to the industrial sector, specifically ammonia/fertilizer plants, and feedstock attributed to refineries for hydrogen production own use. 9/ Fuel used in facilities that liquefy natural gas for export. 10/ Includes consumption of energy by electricity-only and combined-heat-and-power plants that have a regulatory status. 11/ Balancing item. Natural gas lost as a result of converting flow data measured at varying temperatures and pressures to a standard temperature and pressure and the merger of different data reporting systems, which vary in scope, format, definition, and respondent type. 12/ Excludes use for lease and plant fuel and fuel for liquefaction in export facilities. Includes energy for combined heat and power plants that have a non-regulatory status, and small on-site generating systems. 13/ Natural gas used as fuel in motor vehicles, trains, and ships. Price includes estimated motor vehicle fuel taxes and estimated dispensing costs or charges. 14/ Weighted average prices. Weights used are the sectoral consumption values excluding lease, plant, pipeline and distribution fuel, and fuel used for liquefaction in export facilities. Btu = British thermal unit - - = Not applicable Report Scenario Datekey Release Date 2024 38.3956298828125 0.115900009870529 9.65197011828423E-02 -4.73413324356079 -0.368572950363159 -4.36556005477905 33.7773933410645 33.0679016113281 4.43491268157959 3.30125641822815 10.5134963989258 7.66732168197632 1.97422671318054 0.871948540210724 1.33269667625427 8.54158028960228E-02 0.892078101634979 0.355202823877335 13.4855422973633 0.709491729736328 2.19158673286438 2.22762651405785 14.4616289138794 9.91897964477539 3.46013855934143 15.0582962036133 2.81380391120911 5.55181169509888 2.19158673286438 14.4616289138794 9.91897964477539 3.46013855934143 15.0582962036133 2.81380391120911 5.55181169509888 Annual Energy Outlook 2025 ref2025 d032025a 2025 38.5227508544922 0.103800036013126 0.104645431041718 -5.65354537963867 -0.6648770570755 -4.98866701126099 32.9730072021484 32.7471618652344 4.7822732925415 3.47789144515991 10.4707746505737 7.60503005981445 1.97896814346313 0.886776983737946 1.3391045331955 9.28811728954315E-02 0.840421497821808 0.405801892280579 12.677116394043 0.225845336914063 2.87924146652222 2.92658945914353 0.313770257569993 13.2415285110474 8.84817981719971 4.17342519760132 15.6428575515747 3.26110792160034 5.83824110031128 2.93831205368042 13.5131921768188 9.029709815979 4.25904750823975 15.9637870788574 3.32801294326782 5.95801877975464 April 2025 2026 38.935131072998 9.82329174876213E-02 0.104645431041718 -6.64845848083496 -1.33691263198852 -5.31154537200928 32.3849029541016 32.1258926391602 4.81431674957275 3.5097873210907 10.3957281112671 7.4058403968811 2.07743215560913 0.912455141544342 1.36393797397614 9.87217724323273E-02 0.833079814910889 0.432136446237564 12.0421237945557 0.259010314941406 2.73724627494812 2.7822592125346 -4.93168750259804E-02 12.9611434936523 8.90306758880615 4.05630922317505 15.5516319274902 3.17541074752808 5.8081464767456 2.84057688713074 13.4504241943359 9.23915672302246 4.20943450927734 16.1387042999268 3.29528212547302 6.02740335464478 Reference 2027 39.0898818969727 0.092665784060955 0.114842623472214 -6.34270238876343 -1.0238641500473 -5.31883811950684 32.8398475646973 32.5418815612793 4.83457088470459 3.51799416542053 10.4546642303467 7.44569969177246 2.08333969116211 0.925625026226044 1.34000754356384 0.103196762502194 0.803902089595795 0.432908654212952 12.3946437835693 0.297966003417969 2.61820697784424 2.66126236104479 -0.043488705489658 12.5273809432983 8.83302307128906 3.92352437973023 15.4161691665649 3.11481261253357 5.63625860214233 2.7623279094696 13.2169589996338 9.31924247741699 4.13949728012085 16.264762878418 3.28626942634583 5.94650983810425 CPI (Dec 2024) CPI (Apr 2025) CPI Adj 2028 40.2168312072754 8.70986580848694E-02 0.114842623472214 -7.42073059082031 -1.07329559326172 -6.34743595123291 32.8831977844238 32.5367050170898 4.84569406509399 3.51130700111389 10.5046710968018 7.44906377792358 2.12476015090942 0.930846691131592 1.38737976551056 0.106673493981361 0.764299750328064 0.516406536102295 12.287654876709 0.346492767333984 2.72807598114014 2.77293811685446 4.19634521738089E-02 12.2606830596924 8.90461826324463 3.99543929100037 15.4596099853516 3.17183208465576 5.65717935562134 2.93259239196777 13.1798334121704 9.57217311859131 4.29496669769287 16.6185760498047 3.40961599349976 6.08128309249878 315.605 320.795 0.0164446063909 2029 40.8838424682617 8.15315321087837E-02 0.114842623472214 -7.98536968231201 -0.918129444122314 -7.0672402381897 32.9800033569336 32.592658996582 4.83329629898071 3.51203536987305 10.5699090957642 7.4840259552002 2.14046406745911 0.945419251918793 1.41338610649109 0.109713077545166 0.72878086566925 0.574892103672028 12.2640295028687 0.387344360351563 2.89250779151917 2.94007394363331 6.02739115463739E-02 12.1423740386963 9.08860874176025 4.14444875717163 15.5896091461182 3.37234950065613 5.78514719009399 3.16450715065002 13.2841930389404 9.94326400756836 4.53417539596558 17.055591583252 3.68947124481201 6.32915878295898 2030 41.4441986083984 7.59644061326981E-02 0.114842623472214 -8.55409622192383 -0.738482475280762 -7.81561422348022 32.9660682678223 32.6973876953125 4.81391000747681 3.50673580169678 10.6479721069336 7.53929090499878 2.1415011882782 0.967179775238037 1.4356997013092 0.111863851547241 0.688143908977509 0.63569188117981 12.2930698394775 0.268680572509766 3.07968974113464 3.1303340267337 6.47126863976984E-02 12.0156354904175 9.26202869415283 4.31456613540649 15.6939249038696 3.54482388496399 5.89670658111572 3.43224763870239 13.3911666870117 10.3223304748535 4.80849075317383 17.4905414581299 3.95062971115112 6.57175207138062 2031 41.5015716552734 7.59644061326981E-02 0.114842623472214 -8.90063571929932 -0.782009601593018 -8.11862754821777 32.6769027709961 32.3731002807617 4.78318452835083 3.50437641143799 10.7356023788452 7.59696292877197 2.13417148590088 1.00446808338165 1.4490954875946 0.113198302686214 0.675661385059357 0.66023588180542 11.9008417129517 0.303802490234375 3.22615671157837 3.27920958885564 4.75590019628934E-02 12.2079095840454 9.39996147155762 4.46158981323242 15.7898559570313 3.6678102016449 6.06016302108765 3.66940093040466 13.8851642608643 10.6914300918579 5.07457113265991 17.9592380523682 4.17173385620117 6.89277410507202 2032 43.437816619873 7.59644061326981E-02 0.114842623472214 -9.54898262023926 -0.811311483383179 -8.73766994476318 33.9647979736328 33.7070198059082 4.7383279800415 3.49261426925659 10.8969011306763 7.63320446014404 2.18749213218689 1.07620429992676 1.51175510883331 0.113077498972416 0.688299119472504 0.710378468036652 13.0674209594727 0.257778167724609 3.70314455032349 3.76404130486216 0.147850176351711 12.6358070373535 9.74943065643311 4.92096614837646 16.161226272583 4.17704820632935 6.41497802734375 4.30092477798462 14.6755418777466 11.3232326507568 5.71533250808716 18.7700519561768 4.85132837295532 7.45051574707031 2033 43.2266426086426 7.59644061326981E-02 0.114842623472214 -10.257158279419 -1.03853166103363 -9.21862602233887 33.0454483032227 32.8037300109863 4.69911432266235 3.47762799263 10.9637031555176 7.62912464141846 2.18971514701843 1.14486289024353 1.54190707206726 0.112580068409443 0.679991066455841 0.749335885047913 12.1213808059692 0.241718292236328 4.10241889953613 4.16988156358959 0.107820352078281 13.0319080352783 10.0778198242188 5.28364086151123 16.4059181213379 4.46749496459961 6.80691862106323 4.86834478378296 15.4649791717529 11.9593591690063 6.27010202407837 19.4689197540283 5.30158090591431 8.07777690887451 2034 42.8315658569336 7.59644061326981E-02 0.114842623472214 -10.7136487960815 -1.29502189159393 -9.41862678527832 32.1938819885254 31.930118560791 4.66038799285889 3.46663475036621 11.0231323242188 7.62232255935669 2.19170570373535 1.20910501480102 1.55042695999146 0.112636655569076 0.67225444316864 0.765535891056061 11.2295360565185 0.263763427734375 4.33623313903809 4.40754078622874 5.69942380892383E-02 13.2807817459106 10.2646799087524 5.48898983001709 16.4986000061035 4.61806535720825 7.05522012710571 5.2597508430481 16.109281539917 12.4508209228516 6.65801811218262 20.0124206542969 5.60160684585571 8.55781936645508 2035 42.3476371765137 7.59644061326981E-02 0.114842623472214 -10.846357345581 -1.32772994041443 -9.51862621307373 31.5772457122803 31.3074417114258 4.63142442703247 3.46529865264893 11.0652303695679 7.62315940856934 2.18099021911621 1.26108050346374 1.56103229522705 0.113227337598801 0.67416912317276 0.773635923862457 10.5844554901123 0.269804000854492 4.42681407928467 4.4996112943842 0.020889315067288 13.4129295349121 10.3480958938599 5.56704807281494 16.4802055358887 4.66814661026001 7.17875289916992 5.48603630065918 16.6222972869873 12.8241281509399 6.89909887313843 20.4234924316406 5.78511381149292 8.89644336700439 2036 41.9365119934082 7.59644061326981E-02 0.114842623472214 -10.9854888916016 -1.34781718254089 -9.63767051696777 31.0269889831543 30.7671756744385 4.60865163803101 3.47247695922852 11.1000900268555 7.62059497833252 2.17131972312927 1.3081750869751 1.573979139328 0.114579364657402 0.676121413707733 0.783278405666351 10.0119771957397 0.25981330871582 4.42384147644043 4.49658980825623 -6.71499365231672E-04 13.4347734451294 10.3347606658935 5.54441690444946 16.3628826141357 4.64996242523193 7.21203470230103 5.59581279754639 16.9939346313477 13.0726613998413 7.01325273513794 20.6977634429932 5.88183784484863 9.12265872955322 2037 41.304557800293 7.59644061326981E-02 0.114842623472214 -11.1046876907349 -1.38606023788452 -9.71862602233887 30.2758369445801 29.9576988220215 4.59038162231445 3.48527479171753 11.1438360214233 7.6355676651001 2.15042638778686 1.35784232616425 1.57933056354523 0.116604715585709 0.672889888286591 0.789835929870605 9.1588773727417 0.318138122558594 4.37152051925659 4.44340845352551 -1.18270416022992E-02 13.3971195220947 10.2683763504028 5.46440696716309 16.190803527832 4.55644035339355 7.21217393875122 5.64463949203491 17.2987651824951 13.2588386535644 7.05580759048462 20.9060554504395 5.88341379165649 9.31257724761963 2038 40.940559387207 7.59644061326981E-02 0.114842623472214 -11.1474866867065 -1.4288592338562 -9.71862602233887 29.8690376281738 29.4980583190918 4.57447862625122 3.50139260292053 11.2253952026367 7.68470907211304 2.13726949691773 1.40341711044312 1.58565902709961 0.11994519084692 0.67587798833847 0.789835929870605 8.6111307144165 0.370979309082031 4.30854511260986 4.37939744110417 -1.44058357656841E-02 13.3355960845947 10.1789140701294 5.37340307235718 16.0112686157227 4.48407697677612 7.18093490600586 5.6782603263855 17.5750713348389 13.4148588180542 7.08164405822754 21.1013584136963 5.90959501266479 9.46380233764648 2039 40.8509826660156 7.59644061326981E-02 0.114842623472214 -11.1778268814087 -1.45919930934906 -9.71862602233887 29.7491226196289 29.2902488708496 4.55808258056641 3.51756381988525 11.3156232833862 7.74323272705078 2.12660264968872 1.4457882642746 1.59949111938477 0.124871209263802 0.684784054756165 0.789835929870605 8.2994909286499 0.458873748779297 4.24401378631592 4.31380492254944 -1.49775213227038E-02 13.2949991226196 10.1087284088135 5.29968500137329 15.8461027145386 4.42309617996216 7.14222240447998 5.70776748657227 17.8804244995117 13.5952129364014 7.12753772735596 21.3113994598389 5.94861555099487 9.60556411743164 2040 41.1927490234375 7.59644061326981E-02 0.114842623472214 -11.3442106246948 -1.60653936862946 -9.73766994476318 29.924503326416 29.4473724365234 4.53912401199341 3.53095817565918 11.4061584472656 7.78997850418091 2.13072752952576 1.48545229434967 1.61643218994141 0.13153974711895 0.693514049053192 0.791378438472748 8.35470104217529 0.477130889892578 4.26797151565552 4.33815662731805 5.64506397619327E-03 13.3189897537231 10.0993032455444 5.3154935836792 15.758150100708 4.45189666748047 7.1469841003418 5.86075592041016 18.2895679473877 13.8683099746704 7.29920816421509 21.6390075683594 6.11332130432129 9.81420135498047 2041 41.6008110046387 7.59644061326981E-02 0.114842623472214 -11.5518751144409 -1.83324909210205 -9.71862602233887 30.1249008178711 29.6872177124023 4.51464366912842 3.5389997959137 11.4698143005371 7.81370306015015 2.13258457183838 1.52352666854858 1.62980425357819 0.139111116528511 0.700857222080231 0.789835929870605 8.53395557403564 0.43768310546875 4.34474325180054 4.41619084444592 1.79878745355751E-02 13.4435815811157 10.1838216781616 5.40864562988281 15.7634935379028 4.54355382919312 7.21827793121338 6.0935845375061 18.8548774719238 14.2830018997192 7.58572721481323 22.1085968017578 6.37241983413696 10.1237707138062 2042 41.8234519958496 7.59644061326981E-02 0.114842623472214 -11.5827894210815 -1.86416292190552 -9.71862602233887 30.3166275024414 29.7052726745606 4.48784828186035 3.54376363754273 11.5404386520386 7.84271717071533 2.13953304290771 1.55818855762482 1.64820122718811 0.147862672805786 0.710502684116364 0.789835929870605 8.48501777648926 0.611354827880859 4.42047452926636 4.49316749296114 1.74305529870922E-02 13.5530376434326 10.2555360794067 5.49005460739136 15.7565031051636 4.63308000564575 7.30285501480103 6.33502054214478 19.4229755401611 14.6972980499268 7.867844581604 22.5807800292969 6.63970708847046 10.4657850265503 2043 41.9286270141602 7.59644061326981E-02 0.114842623472214 -11.5071058273315 -1.80105316638947 -9.70605278015137 30.497486114502 29.842170715332 4.45946455001831 3.54672193527222 11.6080827713013 7.87585115432739 2.13925933837891 1.59297239780426 1.66793930530548 0.157318636775017 0.721803307533264 0.788817346096039 8.55996417999268 0.655315399169922 4.55521059036255 4.63011923554872 3.04799994218161E-02 13.6621351242065 10.3300743103027 5.58915710449219 15.7701396942139 4.72077131271362 7.38036727905273 6.67345905303955 20.0152549743652 15.1337299346924 8.18820762634277 23.1035175323486 6.91600847244263 10.8123607635498 2044 41.8406028747559 7.59644061326981E-02 0.114842623472214 -11.4690198898315 -1.76063859462738 -9.70838069915771 30.4475479125977 29.9460468292236 4.4323902130127 3.55221915245056 11.6724948883057 7.9081506729126 2.13583254814148 1.62851166725159 1.68631720542908 0.166982918977737 0.730328381061554 0.789005935192108 8.60262775421143 0.501501083374023 4.63927507400513 4.71556612653626 1.84545767917806E-02 13.7249116897583 10.361762046814 5.63906478881836 15.7264108657837 4.74434471130371 7.40905952453613 6.94799137115479 20.5550575256348 15.5182514190674 8.44532299041748 23.5525951385498 7.10534858703613 11.0961484909058 2045 41.7228698730469 7.59644061326981E-02 0.114842623472214 -11.5049810409546 -1.8513914346695 -9.65358924865723 30.2938537597656 29.9889106750488 4.40663862228394 3.55790448188782 11.7299060821533 7.9367265701294 2.12922644615173 1.66395306587219 1.69590222835541 0.177341148257256 0.733993232250214 0.784567832946777 8.598557472229 0.304943084716797 4.69656944274902 4.77380267862256 0.012349853765932 13.8081607818603 10.413007736206 5.68310403823853 15.7022171020508 4.7369589805603 7.43718671798706 7.19250440597534 21.1463413238525 15.9468746185303 8.70332145690918 24.0469703674316 7.25435876846313 11.3895893096924 2046 41.9156532287598 7.59644061326981E-02 0.114842623472214 -11.6741628646851 -2.07320094108582 -9.60096263885498 30.3174552917481 29.994327545166 4.38101434707642 3.5627326965332 11.7736682891846 7.95092487335205 2.12873888015747 1.69400405883789 1.71228075027466 0.188128247857094 0.743847489356995 0.780305027961731 8.5646333694458 0.323127746582031 4.78268384933472 4.86133320272914 1.83355974260413E-02 13.9120063781738 10.4850759506226 5.75579595565796 15.708854675293 4.77366971969604 7.50099897384644 7.49003744125366 21.7872333526611 16.4204082489014 9.01400375366211 24.6012325286865 7.47592115402222 11.7471208572388 2047 41.9209403991699 7.59644061326981E-02 0.114842623472214 -11.7624464035034 -2.09914016723633 -9.66330528259277 30.2344589233398 29.9984264373779 4.35666370391846 3.57020258903503 11.8250913619995 7.98310852050781 2.12959623336792 1.7123863697052 1.73836231231689 0.199378132820129 0.753629267215729 0.785354912281036 8.50810432434082 0.236032485961914 4.83138036727905 4.91083051574368 1.01818392096123E-02 13.9435338973999 10.4869804382324 5.76555204391479 15.6312732696533 4.78120613098145 7.51276636123657 7.73882865905762 22.3345336914063 16.7978801727295 9.23516941070557 25.0379276275635 7.65846014022827 12.0338306427002 2048 42.0398597717285 7.59644061326981E-02 0.114842623472214 -11.8087482452393 -2.09140205383301 -9.71734523773193 30.3070774078369 30.12229347229 4.33486270904541 3.5810284614563 11.9078645706177 8.04124069213867 2.13460469245911 1.73201906681061 1.76623821258545 0.211646035313606 0.764860033988953 0.789732098579407 8.53229904174805 0.184783935546875 4.82803583145142 4.9074309803408 -6.92252642803262E-04 13.9245567321777 10.4432487487793 5.72433376312256 15.5035381317139 4.73721027374268 7.46530246734619 7.9098105430603 22.8127136230469 17.1092586517334 9.37822246551514 25.3995723724365 7.76100969314575 12.2304658889771 2049 42.0715942382813 7.59644061326981E-02 0.114842623472214 -11.7901229858398 -2.07149505615234 -9.71862602233887 30.3574371337891 30.1605110168457 4.31541347503662 3.59396553039551 11.9877433776856 8.10305595397949 2.12960767745972 1.75507950782776 1.79016172885895 0.224915981292725 0.775409817695618 0.789835929870605 8.47322463989258 0.196926116943359 4.80566024780273 4.88468743902625 -4.63451068505327E-03 13.9140214920044 10.4067916870117 5.67077970504761 15.3746042251587 4.67032957077026 7.41734218597412 8.05094432830811 23.3102245330811 17.4345455169678 9.50028324127197 25.7571449279785 7.8242244720459 12.4263067245483 2050 42.0371208190918 7.59644061326981E-02 0.116237945854664 -11.7724304199219 -2.05380344390869 -9.71862602233887 30.3406562805176 30.1633224487305 4.2971978187561 3.60832953453064 12.0567893981934 8.15902233123779 2.12224626541138 1.77552008628845 1.8145192861557 0.239825829863548 0.784857511520386 0.789835929870605 8.38649082183838 0.177333831787109 4.80292463302612 4.8819068381414 -5.69248476910559E-04 13.8872194290161 10.3540620803833 5.62240600585938 15.2366619110107 4.60631895065308 7.37160634994507 8.2266321182251 23.7865581512451 17.7348308563232 9.63027095794678 26.0979347229004 7.8898777961731 12.6263675689697 Avg Annual Change 2024-2050 3.49105686211293E-03 -1.61172788131392E-02 7.17532023103296E-03 3.56580169197391E-02 6.83010861597961E-02 3.12593066990694E-02 -4.11853923153549E-03 -3.52977005570887E-03 -1.21252532991634E-03 3.42669634690784E-03 5.28190547946061E-03 2.39351331577842E-03 2.78457369911123E-03 2.77281660789128E-02 1.19405766539731E-02 4.05058541715742E-02 -4.91294945544329E-03 3.12132387209425E-02 -1.81032087649213E-02 -5.19305248662774E-02 3.06368301070794E-02 -1.55762826673556E-03 1.65247370288335E-03 0.018846591012246 4.53002939274416E-04 1.91382078195133E-02 1.09639504570223E-02 5.21913973119188E-02 1.93236296290951E-02 2.26008651995904E-02 4.01545789253546E-02 2.13763110116465E-02 4.04522915748715E-02 0.032107081191558 Description Cost ($/MMBtu) Short Ton (lbs) GVEA min. coal energy content (BTU/lb) GVEA min. coal energy content (MMBTU/lb) MMBtu / Short Ton Cost ($ / Short Ton) Source: GVEA - Usibelli Coal Mine Contract Price Agreement (2024 - 2029) GVEA Coal Price Forecast (2025 - 2029 held at nominal contract price, out years to 2050 adjusted by EIA AEO price forecast, 2050 onwards held constant) 2025 63.51 Value 4.35 2000 7300 0.0073 14.6 63.51 2026 63.51 2027 63.51 2028 63.51 2029 63.51 2030 65.5294759006921 2031 64.1436563807228 2032 56.6460667858566 2033 56.0659048671851 2034 56.3442808053547 2035 56.0670630851716 2036 56.4166928278515 2037 55.0675151132721 2038 55.4946928147726 2039 59.7660837571159 2040 59.7062892911686 2041 59.6990358047887 2042 59.5393655110595 2043 59.722001278601 2044 58.4022177326173 2045 57.747719277724 2046 60.104306807505 2047 70.1763693036653 2048 69.0110616192291 2049 68.9173161573554 2050 71.1603924748777 2051 71.1603924748777 2052 71.1603924748777 2053 71.1603924748777 2054 71.1603924748777 2055 71.1603924748777 2056 71.1603924748777 2057 71.1603924748777 2058 71.1603924748777 2059 71.1603924748777 2060 71.1603924748777 2061 71.1603924748777 2062 71.1603924748777 2063 71.1603924748777 2064 71.1603924748777 2065 71.1603924748777 2066 71.1603924748777 2067 71.1603924748777 2068 71.1603924748777 2069 71.1603924748777 2070 71.1603924748777 2071 71.1603924748777 2072 71.1603924748777 2073 71.1603924748777 2074 71.1603924748777 2075 71.1603924748777 2076 71.1603924748777 2077 71.1603924748777 2078 71.1603924748777 2079 71.1603924748777 2080 71.1603924748777 2081 71.1603924748777 2082 71.1603924748777 2083 71.1603924748777 2084 71.1603924748777 2085 71.1603924748777 2086 71.1603924748777 2087 71.1603924748777 2088 71.1603924748777 2089 71.1603924748777 2090 71.1603924748777 Adak Akhiok Akiachak Akiak Akutan Alakanuk Allakaket, Alatna Ambler Anaktuvuk Pass Angoon Aniak Anvik Arctic Village Atka Atmautluak Atqasuk Beaver Bethel Bettles, Evansville Birch Creek Brevig Mission Buckland Central Chalkyitsik Chefornak Chenega Bay Chevak Chignik Chignik Lagoon Chignik Lake Chilkat Valley Chistochina Chitina Chuathbaluk Circle Coffman Cove Cold Bay Cordova Craig Crooked Creek Deering Dillingham Diomede Dot Lake Eagle, Eagle Village Eek Egegik Ekwok Elfin Cove Elim Emmonak Fairbanks False Pass Fort Yukon Galena Gambell Golovin Goodnews Bay Grayling Gustavus Haines Healy Lake Hollis Holy Cross Hoonah Hooper Bay Hughes Huslia Hydaburg Igiugig Iliamna-Newhalen-Nondalton Juneau Kake Kaktovik Kalskag Kaltag Karluk Kasigluk Ketchikan Kiana King Cove Kipnuk Kivalina Klawock Klukwan Kobuk Kodiak Kokhanok Koliganek-New Koliganek Kongiganak Kotlik Kotzebue Koyuk Koyukuk Kwethluk Kwigillingok Larsen Bay Levelock Lime Village Lower Kalskag Manley Hot Springs Manokotak Marshall McGrath Mekoryuk Mentasta Metlakatla Minto Mountain Village Naknek-South Naknek-King Salmon Napakiak Napaskiak Naukati Nelson Lagoon New Stuyahok Newtok Nightmute Nikolai Nikolski Noatak Nome Noorvik Northway Nuiqsut Nulato Nunam Iqua Nunapitchuk Old Harbor Ouzinkie Pedro Bay Pelican Perryville Petersburg Pilot Point Pilot Station Pitkas Point Platinum Point Hope Point Lay Port Alsworth Port Heiden Quinhagak Red Devil Ruby Russian Mission Sand Point Savoonga Scammon Bay Selawik Shageluk Shaktoolik Shishmaref Shungnak Sitka Skagway Slana Sleetmute St. George St. Mary's St. Michael St. Paul Stebbins Stony River Takotna Tanana Tatitlek Teller Tenakee Springs Tetlin Thorne Bay Togiak Tok Toksook Bay Tuluksak Tuntutuliak Tununak Twin Hills Unalakleet Unalaska Venetie Wainwright Wales Whale Pass White Mountain Wrangell Yakutat PCE (Jan 2025) 5.71 3.41 4.71 9.5 4.77 5.1 5.88 6.3 6.38 3.24 4.65 4.09 7.77 5.33 4.87 7.41 7.36 4.59 4.64 7.36 4.93 5.06 3.8 6.8 5.04 5.85 4.5 4.5 4.87 3.94 3.24 2.85 3.53 4.47 3.7 3.03 7.19 3.24 3.03 4.47 4.97 3.54 3.18 2.79 3.68 4.8 5.2 4.91 5.71 5.12 5.1 2.24 3.63 6.8 4.1 5.28 4.07 4.26 4.24 4.73 3.66 3.93 3.03 4.15 3.24 4.51 4.94 4.04 3.03 9.22 4.58 3.13 3.24 5.73 5.26 4.09 5.85 4.93 3.13 5.26 7.19 4.76 5.14 3.03 3.66 8.96 4.17 6.5 5.16 4.7 4.55 3.39 5.25 4.83 5.08 3.22 5.85 4.98 4.47 5.26 4.11 3.72 4.21 5.12 4.43 2.85 3.13 3.66 4.02 3.59 0.54 5.04 3.03 5.33 4.91 5.49 4.55 7.76 8.51 10.72 3.59 5.3 3.03 5.26 4.15 4.96 4.93 4.27 4.17 4.58 3.55 4.5 3.03 5.2 3.96 4.02 4.26 5.68 5.74 5.57 4.05 4.61 4.47 7.02 4.02 3.9 5.19 4.9 4.98 3.89 4.88 4.5 8.96 3.13 3.66 2.85 4.47 10.99 4.02 4.71 6.55 4.71 4.47 5.66 3.89 5.65 5.18 4.05 2.79 3.03 4.48 2.79 4.55 12.44 4.95 4.55 4.48 4.24 2.97 7.36 5.67 5.12 3.03 3.08 3.03 4.14 2025 5.71 3.41 4.71 9.5 4.77 5.1 5.88 6.3 6.38 3.24 4.65 4.09 7.77 5.33 4.87 7.41 7.36 4.59 4.64 7.36 4.93 5.06 3.8 6.8 5.04 5.85 4.5 4.5 4.87 3.94 3.24 2.85 3.53 4.47 3.7 3.03 7.19 3.24 3.03 4.47 4.97 3.54 3.18 2.79 3.68 4.8 5.2 4.91 5.71 5.12 5.1 2.24 3.63 6.8 4.1 5.28 4.07 4.26 4.24 4.73 3.66 3.93 3.03 4.15 3.24 4.51 4.94 4.04 3.03 9.22 4.58 3.13 3.24 5.73 5.26 4.09 5.85 4.93 3.13 5.26 7.19 4.76 5.14 3.03 3.66 8.96 4.17 6.5 5.16 4.7 4.55 3.39 5.25 4.83 5.08 3.22 5.85 4.98 4.47 5.26 4.11 3.72 4.21 5.12 4.43 2.85 3.13 3.66 4.02 3.59 0.54 5.04 3.03 5.33 4.91 5.49 4.55 7.76 8.51 10.72 3.59 5.3 3.03 5.26 4.15 4.96 4.93 4.27 4.17 4.58 3.55 4.5 3.03 5.2 3.96 4.02 4.26 5.68 5.74 5.57 4.05 4.61 4.47 7.02 4.02 3.9 5.19 4.9 4.98 3.89 4.88 4.5 8.96 3.13 3.66 2.85 4.47 10.99 4.02 4.71 6.55 4.71 4.47 5.66 3.89 5.65 5.18 4.05 2.79 3.03 4.48 2.79 4.55 12.44 4.95 4.55 4.48 4.24 2.97 7.36 5.67 5.12 3.03 3.08 3.03 4.14 2026 6.66931147158348 3.98289879476352 5.50130595992263 11.0960523607781 5.57138629062228 5.95682810947036 6.86787240856583 7.35843472346339 7.45187516439626 3.78433785778117 5.43122562922298 4.7771425426929 9.07540282560485 6.22546937715236 5.68818684178837 8.65492084140694 8.5965205658239 5.36114529852333 5.41954557410637 8.5965205658239 5.75826717248802 5.91010788900393 4.43842094431125 7.94243747929382 5.88674777877071 6.832832243216 5.25602480247385 5.25602480247385 5.68818684178837 4.60194171594377 3.78433785778117 3.32881570823344 4.12305945616282 5.22098463712402 4.32162039314517 3.53905670033239 8.39795962884155 3.78433785778117 3.53905670033239 5.22098463712402 5.80498739295445 4.13473951127943 3.71425752708152 3.25873537753379 4.29826028291195 5.60642645597211 6.07362866063645 5.7349070622548 6.66931147158348 5.98018821970358 5.95682810947036 2.61633234612032 4.2398600073289 7.94243747929382 4.78882259780951 6.16706910156932 4.75378243245968 4.97570347967524 4.95234336944203 5.52466607015585 4.27490017267873 4.59026166082716 3.53905670033239 4.84722287339255 3.78433785778117 5.26770485759046 5.76994722760463 4.71874226710986 3.53905670033239 10.7690108175131 5.34946524340672 3.65585725149848 3.78433785778117 6.6926715818167 6.1437089913361 4.7771425426929 6.832832243216 5.75826717248802 3.65585725149848 6.1437089913361 8.39795962884155 5.55970623550567 6.0035483299368 3.53905670033239 4.27490017267873 10.4653293844813 4.87058298362577 7.59203582579556 6.02690844017001 5.48962590480602 5.31442507805689 3.9595386845303 6.13202893621949 5.64146662132193 5.93346799923715 3.76097774754795 6.832832243216 5.81666744807106 5.22098463712402 6.1437089913361 4.80050265292612 4.34498050337838 4.9173032040922 5.98018821970358 5.17426441665759 3.32881570823344 3.65585725149848 4.27490017267873 4.69538215687664 4.19313978686247 0.630722976296862 5.88674777877071 3.53905670033239 6.22546937715236 5.7349070622548 6.4123502590181 5.31442507805689 9.06372277048824 9.93972690423388 12.5210190850044 4.19313978686247 6.19042921180253 3.53905670033239 6.1437089913361 4.84722287339255 5.79330733783784 5.75826717248802 4.98738353479185 4.87058298362577 5.34946524340672 4.14641956639604 5.25602480247385 3.53905670033239 6.07362866063645 4.62530182617699 4.69538215687664 4.97570347967524 6.63427130623366 6.70435163693331 6.50579069995096 4.73042232222646 5.38450540875654 5.22098463712402 8.19939869185921 4.69538215687664 4.55522149547734 6.06194860551984 5.72322700713819 5.81666744807106 4.54354144036073 5.69986689690497 5.25602480247385 10.4653293844813 3.65585725149848 4.27490017267873 3.32881570823344 5.22098463712402 12.8363805731528 4.69538215687664 5.50130595992263 7.6504361013786 5.50130595992263 5.22098463712402 6.61091119600044 4.54354144036073 6.59923114088383 6.05026855040323 4.73042232222646 3.25873537753379 3.53905670033239 5.23266469224063 3.25873537753379 5.31442507805689 14.529988565061 5.78162728272123 5.31442507805689 5.23266469224063 4.95234336944203 3.46897636963274 8.5965205658239 6.62259125111705 5.98018821970358 3.53905670033239 3.59745697591543 3.53905670033239 4.83554281827594 2027 6.59529651818444 3.93869722014167 5.44025334512236 10.9729101440897 5.50955593550609 5.89072018261657 6.79165385760499 7.27677199029106 7.36917544413603 3.74233988072112 5.37095075473864 4.72412657782388 8.97468545469231 6.15638011242085 5.6250602528123 8.55886991238996 8.50111775373686 5.30164816435492 5.35940032300802 8.50111775373686 5.69436284319602 5.84451845569409 4.38916405763588 7.8542935768221 5.82141759223285 6.75700256241313 5.19769427877933 5.19769427877933 5.6250602528123 4.55087010186457 3.74233988072112 3.29187304322691 4.07730240090912 5.16304298358747 4.27365974032967 3.49978081437808 8.30476041431631 3.74233988072112 3.49978081437808 5.16304298358747 5.7405645701185 4.08885283263974 3.67303729033739 3.22257045284318 4.25055887686843 5.54420723069795 6.00622449992278 5.67126197973478 6.59529651818444 5.91382104607781 5.89072018261657 2.58729670765904 4.19280671821532 7.8542935768221 4.7356770095545 6.09862795376775 4.70102571436264 4.92048391724443 4.89738305378319 5.46335420858361 4.22745801340719 4.53931967013395 3.49978081437808 4.7934291682076 3.74233988072112 5.20924471050995 5.70591327492664 4.66637441917077 3.49978081437808 10.6494980556323 5.29009773262429 3.61528513168429 3.74233988072112 6.61839738164568 6.0755270903065 4.72412657782388 6.75700256241313 5.69436284319602 3.61528513168429 6.0755270903065 8.30476041431631 5.49800550377547 5.93692190953906 3.49978081437808 4.22745801340719 10.3491868306362 4.81653003166884 7.50778062490348 5.9600227730003 5.42870291339174 5.25544643743243 3.91559635668043 6.06397665857588 5.57885852588981 5.86761931915533 3.71923901725988 6.75700256241313 5.75211500184912 5.16304298358747 6.0755270903065 4.74722744128512 4.29676060379091 4.86273175859133 5.91382104607781 5.11684125666498 3.29187304322691 3.61528513168429 4.22745801340719 4.64327355570953 4.14660499129284 0.62372331345352 5.82141759223285 3.49978081437808 6.15638011242085 5.67126197973478 6.34118702011078 5.25544643743243 8.96313502296169 9.82941740275824 12.3820628152254 4.14660499129284 6.12172881722899 3.49978081437808 6.0755270903065 4.7934291682076 5.72901413838788 5.69436284319602 4.93203434897505 4.81653003166884 5.29009773262429 4.10040326437036 5.19769427877933 3.49978081437808 6.00622449992278 4.57397096532581 4.64327355570953 4.92048391724443 6.56064522299258 6.6299478133763 6.43359047395575 4.6779248509014 5.32474902781616 5.16304298358747 8.10840307489575 4.64327355570953 4.50466837494209 5.99467406819216 5.65971154800416 5.75211500184912 4.49311794321146 5.63661068454292 5.19769427877933 10.3491868306362 3.61528513168429 4.22745801340719 3.29187304322691 5.16304298358747 12.6939244719522 4.64327355570953 5.44025334512236 7.56553278355658 5.44025334512236 5.16304298358747 6.53754435953133 4.49311794321146 6.52599392780071 5.98312363646154 4.6779248509014 3.22257045284318 3.49978081437808 5.17459341531809 3.22257045284318 5.25544643743243 14.3687370728922 5.71746370665726 5.25544643743243 5.17459341531809 4.89738305378319 3.43047822399436 8.50111775373686 6.54909479126195 5.91382104607781 3.49978081437808 3.55753297303119 3.49978081437808 4.78187873647698 2028 6.56081851340386 3.91810702814487 5.41181351981299 10.9155474391133 5.48075381942845 5.85992546731343 6.75614936231431 7.23873145962248 7.33065185910975 3.72277617923442 5.34287322019754 4.69943042378666 8.92776880020105 6.12419661583933 5.59565431878753 8.51412700250834 8.4566767528288 5.27393292058209 5.33138317026163 8.4566767528288 5.66459461840299 5.8139652675698 4.3662189756453 7.81323395641791 5.79098516769798 6.72167921250659 5.17052247115891 5.17052247115891 5.59565431878753 4.52707967474803 3.72277617923442 3.27466423173398 4.05598762737577 5.13605232135119 4.25131847628622 3.48148513058033 8.26134590391835 3.72277617923442 3.48148513058033 5.13605232135119 5.71055481814662 4.06747767731168 3.65383587961897 3.20572393211853 4.2283383764144 5.51522396923617 5.97482596667252 5.64161451853117 6.56081851340386 5.88290556718525 5.85992546731343 2.57377118564355 4.17088812673486 7.81323395641791 4.71092047372256 6.06674636615979 4.67645032391484 4.8947612726971 4.87178117282529 5.43479361968481 4.20535827654258 4.51558962481212 3.48148513058033 4.76837072340211 3.72277617923442 5.18201252109482 5.67608466833889 4.64198017410711 3.48148513058033 10.5938260409078 5.26244287064618 3.59638562993942 3.72277617923442 6.58379861327568 6.04376626628797 4.69943042378666 6.72167921250659 5.66459461840299 3.59638562993942 6.04376626628797 8.26134590391835 5.46926376949254 5.90588566705707 3.48148513058033 4.20535827654258 10.2950847425742 4.79135082327393 7.46853245834065 5.92886576692889 5.40032346987709 5.22797272083846 3.89512692827305 6.03227621635206 5.5496941190439 5.83694536744162 3.6997960793626 6.72167921250659 5.72204486808253 5.13605232135119 6.04376626628797 4.72241052365847 4.27429857615804 4.83731102301756 5.88290556718525 5.09009212160755 3.27466423173398 3.59638562993942 4.20535827654258 4.61900007423529 4.12492792699122 0.620462696539069 5.79098516769798 3.48148513058033 6.12419661583933 5.64161451853117 6.30803741481387 5.22797272083846 8.91627875026514 9.7780324954583 12.3173335312941 4.12492792699122 6.08972646603161 3.48148513058033 6.04376626628797 4.76837072340211 5.69906476821071 5.66459461840299 4.90625132263301 4.79135082327393 5.26244287064618 4.07896772724759 5.17052247115891 3.48148513058033 5.97482596667252 4.55005977461984 4.61900007423529 4.8947612726971 6.52634836359614 6.59528866321159 6.39995781430114 4.65347022404302 5.29691302045391 5.13605232135119 8.0660150550079 4.61900007423529 4.48111947500439 5.96333591673661 5.63012446859526 5.72204486808253 4.46962942506848 5.60714436872344 5.17052247115891 10.2950847425742 3.59638562993942 4.20535827654258 3.27466423173398 5.13605232135119 12.6275648795637 4.61900007423529 5.41181351981299 7.52598270802019 5.41181351981299 5.13605232135119 6.50336826372432 4.46962942506848 6.49187821378841 5.9518458668007 4.65347022404302 3.20572393211853 3.48148513058033 5.1475423712871 3.20572393211853 5.22797272083846 14.2936221202704 5.6875747182748 5.22797272083846 5.1475423712871 4.87178117282529 3.41254483096488 8.4566767528288 6.51485831366023 5.88290556718525 3.48148513058033 3.53893538025988 3.48148513058033 4.7568806734662 2029 6.54691204604526 3.90980211506381 5.40034251083593 10.8924105844886 5.46913668294849 5.84750462956757 6.74182886703084 7.22338807181876 7.31511363463551 3.71488529407822 5.33154833872337 4.68946939900615 8.90884528857647 6.11121562266572 5.58379363646942 8.49608025590112 8.43875177914065 5.26275416661081 5.32008264337128 8.43875177914065 5.65258780858198 5.8016418481592 4.35696423379544 7.79667283942343 5.77871045745501 6.70743178097456 5.15956290844197 5.15956290844197 5.58379363646942 4.51748396872475 3.71488529407822 3.26772317534658 4.04739045928893 5.12516582238569 4.24230728027451 3.47410569168426 8.24383495815506 3.71488529407822 3.47410569168426 5.12516582238569 5.69845058999036 4.05885615464102 3.64609112196566 3.19892900323402 4.21937588957032 5.50353376900477 5.9621615830885 5.6296564178778 6.54691204604526 5.87043602027175 5.84750462956757 2.56831575886889 4.16204741280986 7.79667283942343 4.70093509435824 6.05388714590525 4.66653800830196 4.88438621999173 4.86145482928755 5.42327390154012 4.19644449886614 4.50601827337266 3.47410569168426 4.75826357111871 3.71488529407822 5.17102860379407 5.66405350393408 4.63214092224568 3.47410569168426 10.57137111463 5.25128847125872 3.58876264520519 3.71488529407822 6.56984343674945 6.03095575520106 4.68946939900615 6.70743178097456 5.65258780858198 3.58876264520519 6.03095575520106 8.24383495815506 5.4576709875964 5.89336741097594 3.47410569168426 4.19644449886614 10.2732630354756 4.78119496182289 7.45270197886063 5.91629880168013 5.38887681548384 5.21689138520244 3.88687072435962 6.01949005984897 5.53793085506105 5.82457323886338 3.69195390337403 6.70743178097456 5.70991628534245 5.12516582238569 6.03095575520106 4.71240078971034 4.2652386709787 4.82705774323127 5.87043602027175 5.07930304097732 3.26772317534658 3.58876264520519 4.19644449886614 4.60920953154149 4.11618463140148 0.619147549013037 5.77871045745501 3.47410569168426 6.11121562266572 5.6296564178778 6.29466674829921 5.21689138520244 8.89737959322438 9.75730674463138 12.291225417444 4.11618463140148 6.07681853660943 3.47410569168426 6.03095575520106 4.75826357111871 5.68698489463826 5.65258780858198 4.89585191534383 4.78119496182289 5.25128847125872 4.07032184999311 5.15956290844197 3.47410569168426 5.9621615830885 4.54041535942894 4.60920953154149 4.88438621999173 6.51251495998898 6.58130913210154 6.38639231111595 4.64360661759777 5.285685557315 5.12516582238569 8.04891813716948 4.60920953154149 4.47162118731638 5.95069588773641 5.6181907225257 5.70991628534245 4.46015549196428 5.59525933182152 5.15956290844197 10.2732630354756 3.58876264520519 4.19644449886614 3.26772317534658 5.12516582238569 12.6007991919505 4.60920953154149 5.40034251083593 7.51003045562109 5.40034251083593 5.12516582238569 6.48958356928479 4.46015549196428 6.4781178739327 5.93923019238431 4.64360661759777 3.19892900323402 3.47410569168426 5.13663151773779 3.19892900323402 5.21689138520244 14.263325018004 5.67551919928617 5.21689138520244 5.13663151773779 4.86145482928755 3.4053115195717 8.43875177914065 6.50104926463688 5.87043602027175 3.47410569168426 3.53143416844473 3.47410569168426 4.74679787576661 2030 6.57837719730559 3.92859303727006 5.42629712772492 10.9447606610163 5.49542193189976 5.87560835486138 6.7742308091343 7.25810443835818 7.35027084392463 3.73273942544135 5.35717232355008 4.71200748458491 8.95166214064175 6.14058677086494 5.61062993885783 8.53691331559271 8.47930931211368 5.28804751937524 5.34565152285428 8.47930931211368 5.67975474303267 5.82952515207815 4.37790426440652 7.83414447314851 5.80648355068654 6.73966840704688 5.18436031311298 5.18436031311298 5.61062993885783 4.53919547414781 3.73273942544135 3.28342819830489 4.06684264561974 5.14979791102556 4.26269625744845 3.49080261082941 8.28345570028497 3.73273942544135 3.49080261082941 5.14979791102556 5.7258379458159 4.07836344631555 3.66361462126651 3.21430339413005 4.23965465605684 5.52998433398718 5.99081636181945 5.65671314164106 6.57837719730559 5.89864995625299 5.87560835486138 2.58065935586069 4.18205065257781 7.83414447314851 4.72352828528072 6.0829827673859 4.6889658831933 4.90786109641362 4.88481949502201 5.44933872911654 4.21661305466523 4.52767467345201 3.49080261082941 4.78113228875975 3.73273942544135 5.19588111380879 5.69127554372848 4.65440348110588 3.49080261082941 10.6221782415337 5.27652671867944 3.60601061778747 3.73273942544135 6.6014187986972 6.05994116599429 4.71200748458491 6.73966840704688 5.67975474303267 3.60601061778747 6.05994116599429 8.28345570028497 5.48390113120396 5.92169155764461 3.49080261082941 4.21661305466523 10.3226374234427 4.80417389015136 7.48852045227431 5.94473315903622 5.41477632702912 5.24196431659202 3.90555143587845 6.04842036529848 5.5645467360746 5.85256675346977 3.70969782404974 6.73966840704688 5.7373587465117 5.14979791102556 6.05994116599429 4.73504908597653 4.28573785884007 4.85025709293459 5.89864995625299 5.10371470824234 3.28342819830489 3.60601061778747 4.21661305466523 4.63136187971426 4.13596744979458 0.622123237573558 5.80648355068654 3.49080261082941 6.14058677086494 5.65671314164106 6.32491958199784 5.24196431659202 8.94014133994594 9.80420139213144 12.3502983459047 4.13596744979458 6.10602436877751 3.49080261082941 6.05994116599429 4.78113228875975 5.71431714512009 5.67975474303267 4.91938189710943 4.80417389015136 5.27652671867944 4.08988424701135 5.18436031311298 3.49080261082941 5.99081636181945 4.56223707553943 4.63136187971426 4.90786109641362 6.54381479521817 6.61293959939301 6.41708598756429 4.66592428180168 5.31108912076686 5.14979791102556 8.08760208845625 4.63136187971426 4.49311227136459 5.97929556112364 5.64519234094525 5.7373587465117 4.48159147066878 5.62215073955364 5.18436031311298 10.3226374234427 3.60601061778747 4.21661305466523 3.28342819830489 5.14979791102556 12.6613599646915 4.63136187971426 5.42629712772492 7.54612445575334 5.42629712772492 5.14979791102556 6.52077319382655 4.48159147066878 6.50925239313075 5.96777476042783 4.66592428180168 3.21430339413005 3.49080261082941 5.16131871172137 3.21430339413005 5.24196431659202 14.3318760655835 5.70279634442428 5.24196431659202 5.16131871172137 4.88481949502201 3.42167780665457 8.47930931211368 6.53229399452236 5.89864995625299 3.49080261082941 3.54840661430844 3.49080261082941 4.76961148806395 2031 6.59466744671928 3.93832153998472 5.43973444379121 10.9718635278167 5.50903042396689 5.89015831493316 6.79100605721705 7.27607791844684 7.36847255868109 3.74198292948695 5.37043846361553 4.72367598197581 8.9738294327511 6.15579290560661 5.6245237242597 8.558053551697 8.5003069015506 5.30114248343984 5.35888913358624 8.5003069015506 5.69381970443539 5.84396099481603 4.38874541112667 7.85354441991088 5.82086233475747 6.75635806712921 5.19719851317632 5.19719851317632 5.6245237242597 4.5504360315366 3.74198292948695 3.291559058345 4.07691350033609 5.16255052308847 4.27325211083386 3.49944699887205 8.30396829105283 3.74198292948695 3.49944699887205 5.16255052308847 5.74001702455251 4.08846283036537 3.67268694931126 3.22226307816932 4.2501534507753 5.54367841405474 6.00565161522596 5.67072104437682 6.59466744671928 5.91325697499172 5.89015831493316 2.58704992655888 4.19240680062889 7.85354441991088 4.73522531200509 6.09804625546021 4.70057732191724 4.92001459247358 4.89691593241502 5.46283310384977 4.22705479071674 4.53888670150732 3.49944699887205 4.79297196215149 3.74198292948695 5.20874784320559 5.70536903446467 4.6659293318294 3.49944699887205 10.6484822869968 5.28959315341056 3.61494029916486 3.74198292948695 6.61776610677784 6.07494759540165 4.72367598197581 6.75635806712921 5.69381970443539 3.61494029916486 6.07494759540165 8.30396829105283 5.49748109393761 5.93635563505028 3.49944699887205 4.22705479071674 10.3481997062355 4.81607062221005 7.50706451903246 5.95945429510884 5.42818511376193 5.25494516332272 3.91522287992616 6.06339826537237 5.57832640414258 5.8670596548746 3.71888426942839 6.75635806712921 5.75156635458179 5.16255052308847 6.07494759540165 4.74677464203437 4.29635077089242 4.86226794232717 5.91325697499172 5.11635320297135 3.291559058345 3.61494029916486 4.22705479071674 4.64283067177084 4.14620948051177 0.623663821581158 5.82086233475747 3.49944699887205 6.15579290560661 5.67072104437682 6.34058218607511 5.25494516332272 8.96228010272182 9.82847985491788 12.3808817913889 4.14620948051177 6.12114491551877 3.49944699887205 6.07494759540165 4.79297196215149 5.72846769452323 5.69381970443539 4.93156392250286 4.81607062221005 5.28959315341056 4.10001216039465 5.19719851317632 3.49944699887205 6.00565161522596 4.57353469159516 4.64283067177084 4.92001459247358 6.56001945663144 6.62931543680712 6.43297682630935 4.67747866185868 5.3242411434984 5.16255052308847 8.10762968055505 4.64283067177084 4.50423871141947 5.99410228519668 5.65917171434754 5.75156635458179 4.49268938139019 5.63607305428898 5.19719851317632 10.3481997062355 3.61494029916486 4.22705479071674 3.291559058345 5.16255052308847 12.6927137021795 4.64283067177084 5.43973444379121 7.56481116917886 5.43973444379121 5.16255052308847 6.53692079657288 4.49268938139019 6.5253714665436 5.9825529551674 4.67747866185868 3.22226307816932 3.49944699887205 5.17409985311775 3.22226307816932 5.25494516332272 14.3673665564252 5.71691836449395 5.25494516332272 5.17409985311775 4.89691593241502 3.43015101869637 8.5003069015506 6.54847012660216 5.91325697499172 3.49944699887205 3.55719364901846 3.49944699887205 4.78142263212221 2032 6.50914588857564 3.88724824519141 5.36919039145206 10.829577222674 5.43758772127947 5.81377303533026 6.70293832308665 7.18171963187855 7.27291607164844 3.6934558106804 5.30079306162465 4.66241798323544 8.85745421265021 6.07596279966868 5.55158327099183 8.44707023368573 8.39007245882955 5.23239573179723 5.28939350665341 8.39007245882955 5.61998060081925 5.76817481544531 4.3318308890696 7.75169738044034 5.74537570550284 6.66873965817294 5.12979973705611 5.12979973705611 5.55158327099183 4.4914246586669 3.6934558106804 3.2488731668022 4.02404290484624 5.0956010721424 4.21783533935724 3.45406515628445 8.19628002431854 3.6934558106804 3.45406515628445 5.0956010721424 5.66557882070419 4.03544245981747 3.62505848085298 3.18047583697479 4.19503622941477 5.47178638619318 5.92776858504261 5.59718149087678 6.50914588857564 5.83657214527273 5.81377303533026 2.55350031355682 4.13803845455859 7.75169738044034 4.67381753820668 6.0189650248125 4.63961887329297 4.85621041774645 4.83341130780398 5.39198950139453 4.1722371194723 4.48002510369567 3.45406515628445 4.73081531306286 3.6934558106804 5.14119929202734 5.63138015579048 4.60542020837926 3.45406515628445 10.5103896834794 5.22099617682599 3.5680607059968 3.6934558106804 6.53194499851811 5.99616591487003 4.66241798323544 6.66873965817294 5.61998060081925 3.5680607059968 5.99616591487003 8.19628002431854 5.42618816630824 5.8593712552152 3.45406515628445 4.1722371194723 10.2140012542273 4.75361442300533 7.40971073130327 5.88217036515767 5.35779083648082 5.18679751191229 3.86444913524894 5.98476635989879 5.50598505110689 5.79097392538779 3.67065670073793 6.66873965817294 5.67697837567543 5.0956010721424 5.99616591487003 4.68521709317791 4.24063444929972 4.79921264289027 5.83657214527273 5.05000285225746 3.2488731668022 3.5680607059968 4.1722371194723 4.58262109843679 4.09244023467365 0.615575968446733 5.74537570550284 3.45406515628445 6.07596279966868 5.59718149087678 6.25835567920845 5.18679751191229 8.84605465767898 9.70102128052166 12.2203229291648 4.09244023467365 6.04176413475497 3.45406515628445 5.99616591487003 4.73081531306286 5.65417926573295 5.61998060081925 4.86760997271768 4.75361442300533 5.22099617682599 4.04684201478871 5.12979973705611 3.45406515628445 5.92776858504261 4.51422376860938 4.58262109843679 4.85621041774645 6.47494722366193 6.54334455348935 6.34955211897834 4.6168197633505 5.2551948417397 5.0956010721424 8.00248758980753 4.58262109843679 4.44582643878196 5.91636903007138 5.58578193590554 5.67697837567543 4.43442688381073 5.56298282596307 5.12979973705611 10.2140012542273 3.5680607059968 4.1722371194723 3.2488731668022 5.0956010721424 12.5281109133881 4.58262109843679 5.36919039145206 7.46670850615945 5.36919039145206 5.0956010721424 6.45214811371946 4.43442688381073 6.44074855874822 5.90496947510014 4.6168197633505 3.18047583697479 3.45406515628445 5.10700062711364 3.18047583697479 5.18679751191229 14.1810463842173 5.64277971076172 5.18679751191229 5.10700062711364 4.83341130780398 3.38566782645703 8.39007245882955 6.4635476686907 5.83657214527273 3.45406515628445 3.51106293114063 3.45406515628445 4.71941575809162 2033 6.69062979016194 3.9956300498165 5.51889077262045 11.1315206666442 5.58919511367293 5.97586898946163 6.889825423144 7.38195581051142 7.47569493191475 3.79643441683445 5.44858643156796 4.79241258174472 9.10441216629742 6.24536896349618 5.70636901542709 8.68258611998249 8.62399916910541 5.37828209051547 5.43686904139254 8.62399916910541 5.77667335647958 5.92899942875997 4.45260826665768 7.96782531928217 5.90556464840914 6.85467325261775 5.27282557893673 5.27282557893673 5.70636901542709 4.6166517291135 3.79643441683445 3.33945619999326 4.13623873192148 5.23767340841049 4.33543436490354 3.55036922315073 8.42480353612336 3.79643441683445 3.55036922315073 5.23767340841049 5.82354291718123 4.1479561220969 3.72613007578196 3.26915185894077 4.31199958455271 5.62434728419918 6.09304289121578 5.75323857612875 6.69062979016194 5.99930376981246 5.97586898946163 2.62469539929295 4.25341263367563 7.96782531928217 4.80412997192013 6.1867820126191 4.76897780139389 4.99160821472677 4.96817343437594 5.54232555297128 4.28856480420187 4.60493433893808 3.55036922315073 4.86271692279721 3.79643441683445 5.28454296911215 5.78839074665499 4.73382563086764 3.55036922315073 10.8034337417326 5.36656470034005 3.66754312490488 3.79643441683445 6.71406457051277 6.16334723226827 4.79241258174472 6.85467325261775 5.77667335647958 3.66754312490488 6.16334723226827 8.42480353612336 5.57747772349752 6.02273855016329 3.55036922315073 4.28856480420187 10.4987815971718 4.88615170314804 7.61630361401972 6.04617333051412 5.50717338244503 5.33141252981381 3.97219526946567 6.15162984209285 5.65949945472543 5.9524342091108 3.77299963648362 6.85467325261775 5.83526030735665 5.23767340841049 6.16334723226827 4.81584736209555 4.35886914525437 4.9330212638497 5.99930376981246 5.19080384770883 3.33945619999326 3.66754312490488 4.28856480420187 4.71039085051681 4.20654307297397 0.632739069472408 5.90556464840914 3.55036922315073 6.24536896349618 5.75323857612875 6.43284720630281 5.33141252981381 9.09269477612201 9.97149903927813 12.5610422680448 4.20654307297397 6.21021679296993 3.55036922315073 6.16334723226827 4.86271692279721 5.81182552700582 5.77667335647958 5.00332560490219 4.88615170314804 5.36656470034005 4.15967351227231 5.27282557893673 3.55036922315073 6.09304289121578 4.64008650946433 4.71039085051681 4.99160821472677 6.6554776196357 6.72578196068819 6.52658632770613 4.74554302104306 5.4017168708663 5.23767340841049 8.2256079031413 4.71039085051681 4.56978216841183 6.08132550104036 5.74152118595333 5.83526030735665 4.55806477823642 5.7180864056025 5.27282557893673 10.4987815971718 3.66754312490488 4.28856480420187 3.33945619999326 5.23767340841049 12.877411802781 4.71039085051681 5.51889077262045 7.6748905648968 5.51889077262045 5.23767340841049 6.63204283928487 4.55806477823642 6.62032544910945 6.06960811086495 4.74554302104306 3.26915185894077 3.55036922315073 5.2493907985859 3.26915185894077 5.33141252981381 14.5764333782162 5.80010813683041 5.33141252981381 5.2493907985859 4.96817343437594 3.48006488209824 8.62399916910541 6.64376022946028 5.99930376981246 3.55036922315073 3.60895617402781 3.55036922315073 4.85099953262179 2034 6.71484775512581 4.01009296759703 5.53886741272199 11.1718132528363 5.60942623326622 5.99749974625948 6.91476441333446 7.40867615714407 7.50275458453637 3.81017630938838 5.46830859217777 4.80975960043162 9.13736726047768 6.26797522501236 5.7270242675066 8.71401433721231 8.65521532009212 5.39774977163353 5.45654878875373 8.65521532009212 5.79758308805083 5.95046053256333 4.46872530113452 7.99666632834598 5.92694092571525 6.87948500306235 5.29191154081719 5.29191154081719 5.7270242675066 4.63336254907105 3.81017630938838 3.35154397585089 4.15121060868549 5.25663213054507 4.35112726689414 3.56322043748358 8.45529866188347 3.81017630938838 3.56322043748358 5.25663213054507 5.84462230174698 4.16297041210952 3.73961748884415 3.28098515530666 4.32760766004606 5.64470564353834 6.11509778049986 5.77406348120276 6.71484775512581 6.02101935310756 5.99749974625948 2.63419596698456 4.26880864292587 7.99666632834598 4.82151940385566 6.20917620789217 4.78623999358355 5.00967625864027 4.9861566517922 5.56238701957007 4.30408805319798 4.62160274564701 3.56322043748358 4.88031842097586 3.81017630938838 5.30367134424123 5.80934289147487 4.75096058331143 3.56322043748358 10.8425387569632 5.3859899682095 3.68081847172396 3.81017630938838 6.73836736197389 6.18565660104409 4.80975960043162 6.87948500306235 5.79758308805083 3.68081847172396 6.18565660104409 8.45529866188347 5.59766642984218 6.04453895995564 3.56322043748358 4.30408805319798 10.5367838679382 4.90383802782393 7.64387222562483 6.06805856680371 5.52710760929796 5.35071055793738 3.98657336074895 6.17389679762006 5.67998505381045 5.97398013941141 3.7866567025403 6.87948500306235 5.85638210517102 5.25663213054507 6.18565660104409 4.8332792072797 4.37464687374221 4.95087724152008 6.02101935310756 5.20959291684892 3.35154397585089 3.68081847172396 4.30408805319798 4.72744097646336 4.22176942922972 0.635029384898063 5.92694092571525 3.56322043748358 6.26797522501236 5.77406348120276 6.45613207979697 5.35071055793738 9.12560745705364 10.0075927138565 12.606509270569 4.22176942922972 6.23269581474025 3.56322043748358 6.18565660104409 4.88031842097586 5.83286249832295 5.79758308805083 5.02143606206431 4.90383802782393 5.3859899682095 4.17473021553356 5.29191154081719 3.56322043748358 6.11509778049986 4.65688215591913 4.72744097646336 5.00967625864027 6.6795683448537 6.75012716539793 6.55021050718928 4.76272038673547 5.42126937848161 5.25663213054507 8.25538200367482 4.72744097646336 4.5863233353749 6.10333797707583 5.76230367777872 5.85638210517102 4.57456353195086 5.73878407093064 5.29191154081719 10.5367838679382 3.68081847172396 4.30408805319798 3.35154397585089 5.25663213054507 12.924023963018 4.72744097646336 5.53886741272199 7.70267124274502 5.53886741272199 5.25663213054507 6.65604873800562 4.57456353195086 6.64428893458158 6.09157817365179 4.76272038673547 3.28098515530666 3.56322043748358 5.26839193396912 3.28098515530666 5.35071055793738 14.6291954595035 5.82110269489891 5.35071055793738 5.26839193396912 4.9861566517922 3.49266161693935 8.65521532009212 6.66780854142966 6.02101935310756 3.56322043748358 3.62201945460377 3.56322043748358 4.86855861755182 2035 6.75264157115678 4.03266335510414 5.57004234678607 11.2346926315218 5.64099830024831 6.03125604429065 6.95368343929981 7.45037511353551 7.54498305148516 3.83162148696112 5.49908639332383 4.83683082767623 9.18879597336046 6.30325386589591 5.75925822268538 8.763060252587 8.70393029136847 5.42813043986158 5.48726040108012 8.70393029136847 5.83021417614763 5.98395207531582 4.49387705260872 8.04167472572086 5.96030009082841 6.91820546256869 5.32169650966822 5.32169650966822 5.75925822268538 4.65944094402062 3.83162148696112 3.37040778945654 4.17457526202863 5.2862185329371 4.37561713017165 3.58327564984327 8.50288842322545 3.83162148696112 3.58327564984327 5.2862185329371 5.87751814512245 4.18640125427233 3.76066553349888 3.2994518359943 4.35196514568423 5.67647627697943 6.14951596672772 5.80656219166021 6.75264157115678 6.05490802877806 6.03125604429065 2.6490222625904 4.2928351844657 8.04167472572086 4.84865681991993 6.24412390467738 4.81317884318881 5.03787269581925 5.01422071133183 5.59369433127348 4.32831316119682 4.64761495177691 3.58327564984327 4.90778678113847 3.83162148696112 5.33352250191192 5.84204016839133 4.77770086645769 3.58327564984327 10.903564848698 5.41630444761788 3.70153557228034 3.83162148696112 6.7762935556442 6.22047192018996 4.83683082767623 6.91820546256869 5.83021417614763 3.70153557228034 6.22047192018996 8.50288842322545 5.6291723080046 6.07856001326548 3.58327564984327 4.32831316119682 10.5960890503616 4.93143876562588 7.68689495840965 6.10221199775289 5.55821635454236 5.38082647088676 4.00901137061673 6.20864592794626 5.71195425371056 6.00760405980324 3.8079695024737 6.91820546256869 5.88934413736616 5.2862185329371 6.22047192018996 4.86048281216364 4.39926911465906 4.97874273460071 6.05490802877806 5.23891456396227 3.37040778945654 3.70153557228034 4.32831316119682 4.75404888197027 4.24553121549087 0.638603581160186 5.96030009082841 3.58327564984327 6.30325386589591 5.80656219166021 6.49246974179523 5.38082647088676 9.17696998111675 10.0639193993948 12.6774636852541 4.24553121549087 6.26777588916479 3.58327564984327 6.22047192018996 4.90778678113847 5.86569215287875 5.83021417614763 5.04969868806295 4.93143876562588 5.41630444761788 4.19822724651604 5.32169650966822 3.58327564984327 6.14951596672772 4.68309292850803 4.75404888197027 5.03787269581925 6.71716359442566 6.78811954788791 6.58707767974488 4.7895268587014 5.451782424349 5.2862185329371 8.30184655508242 4.75404888197027 4.61213697504579 6.13768997448401 5.79473619941651 5.88934413736616 4.60031098280208 5.77108421492909 5.32169650966822 10.5960890503616 3.70153557228034 4.32831316119682 3.37040778945654 5.2862185329371 12.9967654758342 4.75404888197027 5.57004234678607 7.74602491962819 5.57004234678607 5.2862185329371 6.69351160993825 4.60031098280208 6.68168561769454 6.12586398224031 4.7895268587014 3.2994518359943 3.58327564984327 5.29804452518081 3.2994518359943 5.38082647088676 14.7115343511717 5.85386616063504 5.38082647088676 5.29804452518081 5.01422071133183 3.51231969638102 8.70393029136847 6.70533760218196 6.05490802877806 3.58327564984327 3.6424056110618 3.58327564984327 4.89596078889476 2036 6.77556472951599 4.04635301710149 5.58895094150969 11.2728309860599 5.66014776879006 6.05173031883214 6.97728907347706 7.47566686443971 7.57059596748021 3.84462867314042 5.51775411422931 4.85325039294578 9.21998913280897 6.32465149007359 5.77880914759069 8.7928081691267 8.73347747972639 5.44655728694893 5.50588797634925 8.73347747972639 5.85000597487107 6.00426576731189 4.50913239442395 8.06897375844286 5.98053349155177 6.94169065983687 5.33976204602836 5.33976204602836 5.77880914759069 4.67525832474483 3.84462867314042 3.38184929581796 4.18874667166225 5.30416363238817 4.39047101562332 3.5954397776591 8.53175313576532 3.84462867314042 3.5954397776591 5.30416363238817 5.89747052639132 4.20061280954231 3.77343184586004 3.31065246853758 4.36673873986319 5.69574618243025 6.17039169763277 5.82627369911095 6.77556472951599 6.07546259459227 6.05173031883214 2.65801488513412 4.30740805046288 8.06897375844286 4.86511653082584 6.26532080067328 4.82951811718565 5.05497473690685 5.03124246114672 5.61268321726981 4.34300646410307 4.66339218686477 3.5954397776591 4.92444722022616 3.84462867314042 5.35162818390842 5.86187211275114 4.79391970354546 3.5954397776591 10.9405791254181 5.43469114906887 3.71410115645973 3.84462867314042 6.79929700527611 6.24158852491315 4.85325039294578 6.94169065983687 5.85000597487107 3.71410115645973 6.24158852491315 8.53175313576532 5.64828163091 6.0991948703524 3.5954397776591 4.34300646410307 10.6320595405365 4.94817949598628 7.71298962204097 6.12292714611252 5.57708480362962 5.39909273542868 4.02262074134137 6.22972238703309 5.73134459607044 6.02799804307202 3.8208963973803 6.94169065983687 5.90933666427139 5.30416363238817 6.24158852491315 4.8769826687059 4.41420329138345 4.99564404750653 6.07546259459227 5.25669908086792 3.38184929581796 3.71410115645973 4.34300646410307 4.77018742778533 4.25994349894263 0.640771445523403 5.98053349155177 3.5954397776591 6.32465149007359 5.82627369911095 6.5145096961546 5.39909273542868 9.20812299492891 10.0980833359336 12.7204998074276 4.25994349894263 6.2890530764334 3.5954397776591 6.24158852491315 4.92444722022616 5.88560438851126 5.85000597487107 5.06684087478691 4.94817949598628 5.43469114906887 4.21247894742237 5.33976204602836 3.5954397776591 6.17039169763277 4.69899060050496 4.77018742778533 5.05497473690685 6.7399663158758 6.81116314315618 6.6094387991951 4.80578584142552 5.47028956270906 5.30416363238817 8.33002879180424 4.77018742778533 4.62779377322458 6.15852555975271 5.81440756123088 5.90933666427139 4.61592763534452 5.79067528547076 5.33976204602836 10.6320595405365 3.71410115645973 4.34300646410307 3.38184929581796 5.30416363238817 13.0408855301893 4.77018742778533 5.58895094150969 7.77232031144128 5.58895094150969 5.30416363238817 6.71623404011567 4.61592763534452 6.70436790223561 6.14665942187265 4.80578584142552 3.31065246853758 3.5954397776591 5.31602977026824 3.31065246853758 5.39909273542868 14.7614755227984 5.8737382506312 5.39909273542868 5.31602977026824 5.03124246114672 3.52424295037872 8.73347747972639 6.72810017799574 6.07546259459227 3.5954397776591 3.65477046705941 3.5954397776591 4.91258108234609 2037 6.85830756707733 4.09576686580275 5.65720291434925 11.4104942009168 5.72926919351294 6.12563372891321 7.06249535804111 7.5669593121869 7.66304768440515 3.89157907483898 5.58513663518557 4.91251802965785 9.33258315169718 6.40188779904067 5.84937965878575 8.90018547671507 8.84013024407867 5.51307035602189 5.57312558865829 8.84013024407867 5.92144593794943 6.07758954280408 4.5641976803667 8.16751163855094 6.05356744974952 7.02646221845927 5.40497093727636 5.40497093727636 5.84937965878575 4.73235233174863 3.89157907483898 3.42314826027503 4.23989942413012 5.36893779769452 4.4440872150939 3.63934709776608 8.6359424531149 3.89157907483898 3.63934709776608 5.36893779769452 5.96949012405855 4.2519104706574 3.81951279567529 3.35108198111134 4.42006512203933 5.76530233309478 6.24574419418601 5.89742384489487 6.85830756707733 6.14965582196777 6.12563372891321 2.6904744221109 4.36000988940293 8.16751163855094 4.92452907618513 6.34183256640426 4.88849593660328 5.11670582062162 5.09268372756706 5.68122500740382 4.39604302898477 4.72034128522135 3.63934709776608 4.98458430882153 3.89157907483898 5.41698198380364 5.93345698447671 4.85246279702144 3.63934709776608 11.0741848981529 5.5010593094946 3.75945756303889 3.89157907483898 6.8823296601319 6.3178104733497 4.91251802965785 7.02646221845927 5.92144593794943 3.75945756303889 6.3178104733497 8.6359424531149 5.71725814698566 6.17367791502233 3.63934709776608 4.39604302898477 10.7618976884436 5.00860640187609 7.80718024273252 6.19770000807689 5.64519186782197 5.46502616991276 4.07174477274819 6.30579942682242 5.80133547267662 6.10161163585865 3.86755698178442 7.02646221845927 5.98150117058584 5.36893779769452 6.3178104733497 4.93654012271241 4.46810930814846 5.05665058798522 6.14965582196777 5.32089361158539 3.42314826027503 3.75945756303889 4.39604302898477 4.82844070396688 4.31196570329381 0.648596512473163 6.05356744974952 3.63934709776608 6.40188779904067 5.89742384489487 6.59406454347716 5.46502616991276 9.3205721051699 10.221400594716 12.875841877245 4.31196570329381 6.36585465945882 3.63934709776608 6.3178104733497 4.98458430882153 5.95747907753127 5.92144593794943 5.1287168671489 5.00860640187609 5.5010593094946 4.26392151718468 5.40497093727636 3.63934709776608 6.24574419418601 4.7563744248032 4.82844070396688 5.11670582062162 6.82227442749549 6.89434070665918 6.6901529156954 4.86447384354872 5.53709244907645 5.36893779769452 8.43175466215112 4.82844070396688 4.68430814563951 6.23373314765873 5.88541279836759 5.98150117058584 4.67229709911223 5.86139070531303 5.40497093727636 10.7618976884436 3.75945756303889 4.39604302898477 3.42314826027503 5.36893779769452 13.2001401334816 4.82844070396688 5.65720291434925 7.86723547536892 5.65720291434925 5.36893779769452 6.79825233444093 4.67229709911223 6.78624128791365 6.22172210113145 4.86447384354872 3.35108198111134 3.63934709776608 5.3809488442218 3.35108198111134 5.46502616991276 14.9417418799373 5.945468031004 5.46502616991276 5.3809488442218 5.09268372756706 3.5672808186024 8.84013024407867 6.81026338096821 6.14965582196777 3.63934709776608 3.69940233040249 3.63934709776608 4.97257326229425 2038 6.87817927857487 4.10763421014717 5.673594466215 11.4435557174188 5.74586955495659 6.14338254303535 7.08295869667605 7.5888843178672 7.68525110285599 3.90285479204599 5.60131937747341 4.92675188255188 9.35962399203621 6.42043704987812 5.86632803619258 8.92597345958666 8.86574421896866 5.52904428873182 5.58927352934981 8.86574421896866 5.93860312493417 6.09519915054095 4.57742228696752 8.19117672404713 6.07110745429376 7.04682115230525 5.42063165561943 5.42063165561943 5.86632803619258 4.7460641606979 3.90285479204599 3.43306671522564 4.25218438763035 5.38449411124863 4.45696380573153 3.64989198145041 8.66096480086749 3.90285479204599 3.64989198145041 5.38449411124863 5.98678651742857 4.26423023575395 3.8305797033044 3.36079162648404 4.43287210948433 5.78200709932739 6.26384102427134 5.91451142868697 6.87817927857487 6.16747423928255 6.14338254303535 2.69826997968612 4.37264286886634 8.19117672404713 4.93879773067548 6.36020780926013 4.90266018630468 5.13153130065306 5.10743960440586 5.6976861624622 4.40878041323713 4.7340183125743 3.64989198145041 4.99902697129347 3.90285479204599 5.43267750374302 5.95064897305777 4.86652264193389 3.64989198145041 11.106271969958 5.51699844060822 3.7703504626864 3.90285479204599 6.90227097482207 6.33611611301293 4.92675188255188 7.04682115230525 5.93860312493417 3.7703504626864 6.33611611301293 8.66096480086749 5.73382370683299 6.19156593552975 3.64989198145041 4.40878041323713 10.7930799187445 5.02311866754067 7.82980128033917 6.21565763177694 5.6615486180914 5.48086089623742 4.08354251389997 6.32407026488933 5.81814464369818 6.11929084678815 3.87876309579879 7.04682115230525 5.99883236555217 5.38449411124863 6.33611611301293 4.95084357879908 4.48105550197873 5.07130206003506 6.16747423928255 5.33631071875423 3.43306671522564 3.7703504626864 4.40878041323713 4.84243094568669 4.32445947637194 0.650475798674331 6.07110745429376 3.64989198145041 6.42043704987812 5.91451142868697 6.6131706198557 5.48086089623742 9.34757814391261 10.2510167531825 12.9131491884978 4.32445947637194 6.38429950550733 3.64989198145041 6.33611611301293 4.99902697129347 5.97474066930497 5.93860312493417 5.14357714877666 5.02311866754067 5.51699844060822 4.27627608387755 5.42063165561943 3.64989198145041 6.26384102427134 4.7701558569451 4.84243094568669 5.13153130065306 6.84204173420408 6.91431682294567 6.70953740484449 4.87856849005748 5.55313598497901 5.38449411124863 8.45618538276631 4.84243094568669 4.6978807682035 6.25179517614774 5.90246558056337 5.99883236555217 4.6858349200799 5.87837388431618 5.42063165561943 10.7930799187445 3.7703504626864 4.40878041323713 3.43306671522564 5.38449411124863 13.238387087835 4.84243094568669 5.673594466215 7.89003052095717 5.673594466215 5.38449411124863 6.81795003795688 4.6858349200799 6.80590418983328 6.23974932802414 4.87856849005748 3.36079162648404 3.64989198145041 5.39653995937223 3.36079162648404 5.48086089623742 14.9850350657568 5.96269482118137 5.48086089623742 5.39653995937223 5.10743960440586 3.57761689270882 8.86574421896866 6.82999588608048 6.16747423928255 3.64989198145041 3.71012122206841 3.64989198145041 4.98698112316987 2039 6.92156334011064 4.13354308052141 5.70938061855011 11.5157358548251 5.78211158184374 6.18213187995871 7.12763440277593 7.63675114583135 7.73372576355619 3.92747201785612 5.63664965525648 4.95782733118258 9.41865974652533 6.46093390591764 5.90332985399979 8.98227396676354 8.92166483068552 5.56391869196284 5.62452782804087 8.92166483068552 5.97606081729342 6.13364457109629 4.60629434193002 8.24284250661162 6.10940091666508 7.09126892112911 5.45482224702239 5.45482224702239 5.90332985399979 4.7759999229485 3.92747201785612 3.45472075644752 4.27900500710868 5.41845676537558 4.48507606977397 3.67291364632841 8.71559376802023 3.92747201785612 3.67291364632841 5.41845676537558 6.02454812615584 4.29112683432428 3.85474105456249 3.38198979315388 4.46083241534276 5.81847706349055 6.30335015211477 5.95181716286221 6.92156334011064 6.20637553438992 6.18213187995871 2.71528929629559 4.40022327926473 8.24284250661162 4.96994915839818 6.40032476983961 4.93358367675137 5.16389839384787 5.13965473941666 5.73362427298132 4.43658876091155 4.76387809573289 3.67291364632841 5.03055829447621 3.92747201785612 5.466944074238 5.98818264450903 4.89721819510455 3.67291364632841 11.1763246927881 5.55179686474724 3.79413191848447 3.92747201785612 6.94580699454185 6.3760811154084 4.95782733118258 7.09126892112911 5.97606081729342 3.79413191848447 6.3760811154084 8.71559376802023 5.76998975462813 6.23061918882114 3.67291364632841 4.43658876091155 10.8611571851824 5.05480194890742 7.87918769014346 6.25486284325234 5.6972587913345 5.51543138310042 4.1092994260902 6.36395928819279 5.85484254513737 6.1578882255275 3.90322836342491 7.09126892112911 6.03666995337145 5.41845676537558 6.3760811154084 4.98207098561379 4.50931972420518 5.10328925776984 6.20637553438992 5.36996945651315 3.45472075644752 3.79413191848447 4.43658876091155 4.87297454067334 4.35173597040231 0.654578669642687 6.10940091666508 3.67291364632841 6.46093390591764 5.95181716286221 6.65488314136732 5.51543138310042 9.40653791930973 10.3156749604801 12.9945987751289 4.35173597040231 6.42456842427082 3.67291364632841 6.3760811154084 5.03055829447621 6.01242629894024 5.97606081729342 5.17602022106347 5.05480194890742 5.55179686474724 4.30324866153989 5.45482224702239 3.67291364632841 6.30335015211477 4.80024357737971 4.87297454067334 5.16389839384787 6.88519785846382 6.95792882175745 6.75185775909216 4.90934002232015 5.58816234639405 5.41845676537558 8.50952270535493 4.87297454067334 4.72751261408608 6.29122832489916 5.93969533564661 6.03666995337145 4.71539078687047 5.9154516812154 5.45482224702239 10.8611571851824 3.79413191848447 4.43658876091155 3.45472075644752 5.41845676537558 13.3218881099503 4.87297454067334 5.70938061855011 7.93979682622149 5.70938061855011 5.41845676537558 6.86095420403261 4.71539078687047 6.84883237681701 6.27910649768356 4.90934002232015 3.38198979315388 3.67291364632841 5.43057859259118 3.38198979315388 5.51543138310042 15.079553056213 6.00030447172464 5.51543138310042 5.43057859259118 5.13965473941666 3.60018268303478 8.92166483068552 6.87307603124821 6.20637553438992 3.67291364632841 3.73352278240644 3.67291364632841 5.0184364672606 2040 6.97205243580196 4.16369506236159 5.75102749082789 11.5997369772537 5.82428898752633 6.22722721936778 7.17962667644755 7.69245715333666 7.79013914893459 3.956120821716 5.67776599412945 4.99399202494396 9.48736382244855 6.50806295671181 5.94639148202374 9.04779484225789 8.98674359500918 5.604504497431 5.6655557446797 8.98674359500918 6.01965297872218 6.17838622156881 4.63989479090148 8.3029696258237 6.15396572266933 7.14299592809833 5.49461225238333 5.49461225238333 5.94639148202374 4.81083828319785 3.956120821716 3.47992109317611 4.31021805575848 5.45798150403411 4.51779229640407 3.69970558327144 8.77916935436359 3.956120821716 3.69970558327144 5.45798150403411 6.06849397652115 4.32242830520822 3.88285932501756 3.40665959647767 4.49337179750459 5.86091973587556 6.34932971386518 5.9952324798227 6.97205243580196 6.25164771826726 6.22722721936778 2.73509587674193 4.43232055025589 8.3029696258237 5.0062022743937 6.44701170946311 4.96957152604448 5.20156626558955 5.17714576669007 5.77544798972737 4.46895129860511 4.79862803374811 3.69970558327144 5.06725352164241 3.956120821716 5.50682250183307 6.03186322817192 4.93294077769526 3.69970558327144 11.257849992661 5.59229424798126 3.82180807776885 3.956120821716 6.99647293470144 6.42259121056363 4.99399202494396 7.14299592809833 6.01965297872218 3.82180807776885 6.42259121056363 8.77916935436359 5.81207873807659 6.27606821716674 3.69970558327144 4.46895129860511 10.9403835069677 5.09167402054189 7.93666214233148 6.30048871606622 5.73881724137815 5.55566349963204 4.13927456346211 6.41038096111389 5.89755048422478 6.2028067204683 3.93170032281652 7.14299592809833 6.08070422597089 5.45798150403411 6.42259121056363 5.01841252384344 4.54221279530355 5.14051501834085 6.25164771826726 5.40914050623514 3.47992109317611 3.82180807776885 4.46895129860511 4.90852027879577 4.38347955245693 0.659353470286 6.15396572266933 3.69970558327144 6.50806295671181 5.9952324798227 6.70342694790767 5.55566349963204 9.47515357299881 10.3909222817294 13.0893874101221 4.38347955245693 6.47143220836259 3.69970558327144 6.42259121056363 5.06725352164241 6.05628372707141 6.01965297872218 5.2137765150393 5.09167402054189 5.59229424798126 4.33463855465796 5.49461225238333 3.69970558327144 6.34932971386518 4.83525878209733 4.90852027879577 5.20156626558955 6.93542168745274 7.00868318415118 6.80110894350559 4.945151027145 5.62892499633048 5.45798150403411 8.571595113718 4.90852027879577 4.76199728539889 6.33711946441544 5.98302223037296 6.08070422597089 4.74978703594915 5.95860173147348 5.49461225238333 10.9403835069677 3.82180807776885 4.46895129860511 3.47992109317611 5.45798150403411 13.4190641452651 4.90852027879577 5.75102749082789 7.99771338958018 5.75102749082789 5.45798150403411 6.91100118855326 4.74978703594915 6.89879093910352 6.3249092149657 4.945151027145 3.40665959647767 3.69970558327144 5.47019175348385 3.40665959647767 5.55566349963204 15.1895503154775 6.04407347762167 5.55566349963204 5.47019175348385 5.17714576669007 3.626444086573 8.98674359500918 6.923211438003 6.25164771826726 3.69970558327144 3.76075683052015 3.69970558327144 5.05504327219267 2041 7.0085778173449 4.18550794345817 5.78115613304632 11.6605060008365 5.85480143410423 6.25985058992277 7.21723950367566 7.73275661108107 7.83095034582495 3.9768462571274 5.70751083198841 5.0201546887812 9.53706648699998 6.54215757731144 5.97754360253409 9.0951946806525 9.03382359643757 5.63386553093049 5.69523661514542 9.03382359643757 6.05118890359201 6.21075372255082 4.66420240033461 8.34646745323036 6.18620528886486 7.18041685314671 5.52339757934362 5.52339757934362 5.97754360253409 4.83604143613641 3.9768462571274 3.49815180025096 4.332798545574 5.48657492881466 4.54146023190475 3.7190877034247 8.82516191010681 3.9768462571274 3.7190877034247 5.48657492881466 6.10028577096395 4.34507276241698 3.90320095606949 3.42450649919304 4.51691179821878 5.8916240846332 6.38259275835263 6.02664046990604 7.0085778173449 6.28439902360874 6.25985058992277 2.74942457282882 4.45554071400385 8.34646745323036 5.03242890562419 6.48078649309651 4.99560625509523 5.22881637511196 5.20426794142599 5.80570456673229 4.49236336453281 4.82376721929343 3.7190877034247 5.09379998983912 3.9768462571274 5.5356717961866 6.063463120435 4.95878360456627 3.7190877034247 11.3168279292329 5.6215913140875 3.84182987185456 3.9768462571274 7.03312625103088 6.45623805941054 5.0201546887812 7.18041685314671 6.05118890359201 3.84182987185456 6.45623805941054 8.82516191010681 5.84252721726125 6.30894745729471 3.7190877034247 4.49236336453281 10.9976982913153 5.11834842352509 7.97824094794078 6.33349589098068 5.76888191620334 5.58476866355855 4.16095950977219 6.44396384256756 5.92844673516215 6.2353021562368 3.95229782344144 7.18041685314671 6.11255998780694 5.48657492881466 6.45623805941054 5.04470312246717 4.56600866559073 5.16744529089703 6.28439902360874 5.43747806144272 3.49815180025096 3.84182987185456 4.49236336453281 4.9342351708803 4.40644384663191 0.662807709521234 6.18620528886486 3.7190877034247 6.54215757731144 6.02664046990604 6.73854504679922 5.58476866355855 9.524792270157 10.4453585333809 13.1579604556808 4.40644384663191 6.50533492678249 3.7190877034247 6.45623805941054 5.09379998983912 6.08801155412097 6.05118890359201 5.24109059195495 5.11834842352509 5.6215913140875 4.35734697925996 5.52339757934362 3.7190877034247 6.38259275835263 4.86058986982239 4.9342351708803 5.22881637511196 6.97175516681595 7.04540046787386 6.8367387815431 4.97105782140926 5.65841396461646 5.48657492881466 8.61650022377605 4.9342351708803 4.78694456876447 6.37031854150964 6.01436625306305 6.11255998780694 4.77467035192148 5.98981781937708 5.52339757934362 10.9976982913153 3.84182987185456 4.49236336453281 3.49815180025096 5.48657492881466 13.4893643104414 4.9342351708803 5.78115613304632 8.03961203215571 5.78115613304632 5.48657492881466 6.94720673312997 4.77467035192148 6.93493251628699 6.35804432466665 4.97105782140926 3.42450649919304 3.7190877034247 5.49884914565765 3.42450649919304 5.58476866355855 15.2691257526744 6.07573733727798 5.58476866355855 5.49884914565765 5.20426794142599 3.64544240236679 9.03382359643757 6.95948094997296 6.28439902360874 3.7190877034247 3.78045878763963 3.7190877034247 5.08152577299613 2042 6.98592481237564 4.17197961649754 5.76247037938516 11.6228171134096 5.83587764536459 6.23961760825145 7.19391206598403 7.70776292784003 7.80563928247927 3.96399236288916 5.68906311340574 5.00392863093107 9.50624094433603 6.52101212783926 5.95822308866364 9.06579734845947 9.00462462680994 5.61565584742631 5.67682856907583 9.00462462680994 6.03163035464307 6.19067943093183 4.64912684536383 8.31949014433527 6.16621034227203 7.15720843299431 5.50554494845716 5.50554494845716 5.95822308866364 4.8204104659825 3.96399236288916 3.48684513402287 4.3187941484564 5.46884131546745 4.52678140206478 3.70706693196116 8.79663737320156 3.96399236288916 3.70706693196116 5.46884131546745 6.08056853196269 4.3310286927863 3.89058509690973 3.41343786804344 4.50231231340497 5.87258127835431 6.3619630515505 6.00716126598326 6.98592481237564 6.26408669691126 6.23961760825145 2.74053792989868 4.44113959175545 8.31949014433527 5.01616317526097 6.45983940618974 4.97945954227126 5.21191588453945 5.18744679587964 5.78693946804497 4.47784322474516 4.80817592165259 3.70706693196116 5.0773358969105 3.96399236288916 5.51777949278707 6.04386489897298 4.94275590928154 3.70706693196116 11.2802498721722 5.6034213030964 3.8294123752602 3.96399236288916 7.01039390103546 6.43537031752993 5.00392863093107 7.15720843299431 6.03163035464307 3.8294123752602 6.43537031752993 8.79663737320156 5.82364310103469 6.28855578557107 3.70706693196116 4.47784322474516 10.9621517195947 5.1018049855703 7.95245381443812 6.31302487423088 5.75023583505526 5.56671767010669 4.14751052783773 6.42313577320003 5.90928491134402 6.21514851959164 3.93952327422935 7.15720843299431 6.0928030762926 5.46884131546745 6.43537031752993 5.02839771959087 4.55125049072459 5.15074316288992 6.26408669691126 5.41990313814783 3.48684513402287 3.8294123752602 4.47784322474516 4.91828682062173 4.39220141443583 0.66066539381486 6.16621034227203 3.70706693196116 6.52101212783926 6.00716126598326 6.71676483711774 5.56671767010669 9.49400640000613 10.411597224749 13.115431521658 4.39220141443583 6.48430849484955 3.70706693196116 6.43537031752993 5.0773358969105 6.06833398763278 6.03163035464307 5.22415042886935 5.1018049855703 5.6034213030964 4.3432632371162 5.50554494845716 3.70706693196116 6.3619630515505 4.8448795546423 4.91828682062173 5.21191588453945 6.94922117938593 7.02262844536536 6.81464119175698 4.95499045361145 5.64012493608612 5.46884131546745 8.58865011959317 4.91828682062173 4.77147228866288 6.3497285072206 5.99492672165336 6.0928030762926 4.75923774433297 5.97045763299355 5.50554494845716 10.9621517195947 3.8294123752602 4.47784322474516 3.48684513402287 5.46884131546745 13.4457642185654 4.91828682062173 5.76247037938516 8.01362653608765 5.76247037938516 5.46884131546745 6.92475209072612 4.75923774433297 6.91251754639622 6.33749396289069 4.95499045361145 3.41343786804344 3.70706693196116 5.48107585979736 3.41343786804344 5.56671767010669 15.2197731464016 6.05609944330288 5.56671767010669 5.48107585979736 5.18744679587964 3.63365966598173 9.00462462680994 6.93698663505602 6.26408669691126 3.70706693196116 3.76823965361068 3.70706693196116 5.06510135258059 2043 7.14556295305074 4.26731517861699 5.89415087720998 11.8884147204872 5.96923560176042 6.38220158678788 7.35830300594367 7.88389607779679 7.98400904386405 4.05457512572406 5.81906615265954 5.11827539018871 9.7234718292827 6.67002636423125 6.0943768093445 9.27296348198004 9.210392878188 5.74398142810909 5.80655203190113 9.210392878188 6.16946153389495 6.33214510375424 4.75536588819489 8.50960211571717 6.30711686223743 7.32076064366845 5.63135434128342 5.63135434128342 6.0943768093445 4.9305635788126 4.05457512572406 3.56652441614617 4.41748462771789 5.5938119790082 4.63022468061081 3.7917785897975 8.99765282529507 4.05457512572406 3.7917785897975 5.5938119790082 6.21951801692858 4.42999874847629 3.97949040117362 3.49143969159572 4.605196439094 6.00677796403565 6.50734279437195 6.14443329237813 7.14556295305074 6.40722982830469 6.38220158678788 2.8031630498833 4.54262583530196 8.50960211571717 5.13078951094712 6.60745576043922 5.09324714867189 5.33101544308164 5.30598720156482 5.9191791187268 4.58016819757718 4.91804945805419 3.7917785897975 5.19336011473916 4.05457512572406 5.64386846204183 6.18197565465336 5.05570478639667 3.7917785897975 11.5380193392518 5.73146730735068 3.91691979738158 4.05457512572406 7.17059119456756 6.5824275189224 5.11827539018871 7.32076064366845 6.16946153389495 3.91691979738158 6.5824275189224 8.99765282529507 5.95672148100202 6.43225806982151 3.7917785897975 4.58016819757718 11.2126521995332 5.21838835625597 8.13417849296494 6.45728631133832 5.88163675645157 5.69392494507546 4.24228693710018 6.56991339816399 6.04432032631087 6.35717334527106 4.02954688420725 7.32076064366845 6.23203213768699 5.5938119790082 6.5824275189224 5.14330363170552 4.65525292212763 5.2684448392896 6.40722982830469 5.54375549597456 3.56652441614617 3.91691979738158 4.58016819757718 5.03067654487985 4.49256935226833 0.67576252095401 6.30711686223743 3.7917785897975 6.67002636423125 6.14443329237813 6.87025229636577 5.69392494507546 9.7109577085243 10.6495167654049 13.415137453013 4.49256935226833 6.63248400195603 3.7917785897975 6.5824275189224 5.19336011473916 6.20700389617017 6.16946153389495 5.34352956384005 5.21838835625597 5.73146730735068 4.4425128692347 5.63135434128342 3.7917785897975 6.50734279437195 4.95559182032941 5.03067654487985 5.33101544308164 7.10802059077552 7.18310531532596 6.97036526243303 5.06821890715508 5.7690096696259 5.5938119790082 8.78491277240214 5.03067654487985 4.88050709577897 6.49482867361355 6.13191917161972 6.23203213768699 4.86799297502056 6.10689093010291 5.63135434128342 11.2126521995332 3.91691979738158 4.58016819757718 3.56652441614617 5.5938119790082 13.75301871349 5.03067654487985 5.89415087720998 8.19674909675698 5.89415087720998 5.5938119790082 7.0829923492587 4.86799297502056 7.0704782285003 6.48231455285514 5.06821890715508 3.49143969159572 3.7917785897975 5.60632609976661 3.49143969159572 5.69392494507546 15.5675662234591 6.19448977541176 5.69392494507546 5.60632609976661 5.30598720156482 3.71669386524706 9.210392878188 7.09550647001711 6.40722982830469 3.7917785897975 3.85434919358954 3.7917785897975 5.18084599398075 2044 7.05534522847855 4.2134373431019 5.81973310440175 11.7383151787296 5.89386983184636 6.3016218327917 7.26539928957161 7.78435638168387 7.88320535161001 4.00338328200885 5.74559637695715 5.05365358747413 9.60070620407677 6.58581262132937 6.01743104425404 9.15588583940912 9.09410523320529 5.67145964951253 5.73324025571637 9.09410523320529 6.09156777169865 6.25219734782863 4.69532607149186 8.40216244372227 6.2274851053471 7.22833092584931 5.56025455834562 5.56025455834562 6.01743104425404 4.86831176886261 4.00338328200885 3.52149455361889 4.36171079799112 5.52318619462332 4.57176485908418 3.74390473595272 8.88405117211223 4.00338328200885 3.74390473595272 5.52318619462332 6.14099225666172 4.37406691923189 3.92924655456424 3.44735782617429 4.54705261660264 5.93093819556866 6.42518304519938 6.06685552921711 7.05534522847855 6.32633407527324 6.3016218327917 2.76777115793204 4.4852720103988 8.40216244372227 5.0660097087149 6.52403201512553 5.0289413449926 5.26370764856719 5.23899540608565 5.84444534688329 4.5223403741211 4.85595564762184 3.74390473595272 5.12779031491874 4.00338328200885 5.57261067958639 6.10392389293942 4.99187298127029 3.74390473595272 11.3923437839881 5.65910352827176 3.8674659483604 4.00338328200885 7.08005747096009 6.49931977264399 5.05365358747413 7.22833092584931 6.09156777169865 3.8674659483604 6.49931977264399 8.88405117211223 5.88151371060559 6.35104631775478 3.74390473595272 4.5223403741211 11.0710846317282 5.15250255740027 8.03147880649923 6.37575856023631 5.80737698316098 5.62203516454946 4.18872510062037 6.48696365140323 5.96800655929097 6.27690959031017 3.97867103952731 7.22833092584931 6.15334837790249 5.52318619462332 6.49931977264399 5.07836582995567 4.59647710156571 5.20192704236335 6.32633407527324 5.47376170966024 3.52149455361889 3.8674659483604 4.5223403741211 4.96716073878875 4.43584752543573 0.667230547001474 6.2274851053471 3.74390473595272 6.58581262132937 6.06685552921711 6.78351056118166 5.62203516454946 9.588350082836 10.5150591758936 13.2457619701033 4.43584752543573 6.54874425760706 3.74390473595272 6.49931977264399 5.12779031491874 6.12863613542095 6.09156777169865 5.27606376980795 5.15250255740027 5.65910352827176 4.38642304047265 5.56025455834562 3.74390473595272 6.42518304519938 4.89302401134415 4.96716073878875 5.26370764856719 7.01827686475625 7.09241359220086 6.8823595311078 5.00422910251106 5.69617189199407 5.52318619462332 8.67399711101917 4.96716073878875 4.81888728389954 6.41282692395862 6.05449940797634 6.15334837790249 4.80653116265877 6.02978716549481 5.56025455834562 11.0710846317282 3.8674659483604 4.5223403741211 3.52149455361889 5.52318619462332 13.5793772436041 4.96716073878875 5.81973310440175 8.09325941270307 5.81973310440175 5.52318619462332 6.99356462227471 4.80653116265877 6.98120850103395 6.40047080271785 5.00422910251106 3.44735782617429 3.74390473595272 5.53554231586409 3.44735782617429 5.62203516454946 15.3710148235155 6.11628001418018 5.62203516454946 5.53554231586409 5.23899540608565 3.66976800850811 9.09410523320529 7.00592074351548 6.32633407527324 3.74390473595272 3.80568534215656 3.74390473595272 5.11543419367797 2045 7.13750080402795 4.2625004801638 5.88750066321745 11.8750013376997 5.96250067166608 6.37500071813355 7.35000082796573 7.87500088710614 7.97500089837098 4.05000045622602 5.81250065476882 5.11250057591494 9.71250109409757 6.66250075051996 6.08750068574713 9.2625010434058 9.20000103636528 5.73750064632019 5.80000065336072 9.20000103636528 6.16250069419576 6.32500071250112 4.7500005350799 8.50000095751139 6.30000070968492 7.31250082374142 5.62500063364724 5.62500063364724 6.08750068574713 4.92500055479337 4.05000045622602 3.56250040130992 4.41250049706106 5.58750062942293 4.62500052099885 3.78750042665581 8.98750101242749 4.05000045622602 3.78750042665581 5.58750062942293 6.21250069982818 4.42500049846917 3.97500044777739 3.48750039286129 4.60000051818264 6.0000006758904 6.50000073221459 6.13750069137955 7.13750080402795 6.40000072094975 6.37500071813355 2.80000031541552 4.53750051114211 8.50000095751139 5.12500057732304 6.60000074347944 5.08750057309873 5.32500059985272 5.30000059703651 5.91250066603366 4.57500051536643 4.91250055338526 3.78750042665581 5.18750058436357 4.05000045622602 5.63750063505535 6.17500069560387 5.05000056887442 3.78750042665581 11.5250012982728 5.72500064491208 3.91250044073686 4.05000045622602 7.16250080684416 6.57500074066323 5.11250057591494 7.31250082374142 6.16250069419576 3.91250044073686 6.57500074066323 8.98750101242749 5.95000067025797 6.42500072376596 3.78750042665581 4.57500051536643 11.2000012616621 5.21250058717978 8.12500091526824 6.45000072658217 5.87500066180935 5.68750064068777 4.23750047734759 6.56250073925512 6.03750068011471 6.35000071531734 4.02500045340981 7.31250082374142 6.22500070123628 5.58750062942293 6.57500074066323 5.13750057873115 4.65000052381505 5.2625005928122 6.40000072094975 5.53750062379051 3.56250040130992 3.91250044073686 4.57500051536643 5.0250005660582 4.48750050550969 0.675000076037669 6.30000070968492 3.78750042665581 6.66250075051996 6.13750069137955 6.86250077304964 5.68750064068777 9.70000109268947 10.6375011982973 13.4000015094885 4.48750050550969 6.62500074629564 3.78750042665581 6.57500074066323 5.18750058436357 6.20000069842007 6.16250069419576 5.33750060126083 5.21250058717978 5.72500064491208 4.43750049987727 5.62500063364724 3.78750042665581 6.50000073221459 4.95000055760958 5.0250005660582 5.32500059985272 7.10000079980363 7.17500080825226 6.96250078431448 5.06250057028252 5.7625006491364 5.58750062942293 8.7750009884897 5.0250005660582 4.87500054916095 6.48750073080649 6.12500068997144 6.22500070123628 4.86250054775284 6.10000068715523 5.62500063364724 11.2000012616621 3.91250044073686 4.57500051536643 3.56250040130992 5.58750062942293 13.7375015475074 5.0250005660582 5.88750066321745 8.18750092230877 5.88750066321745 5.58750062942293 7.07500079698742 4.86250054775284 7.06250079557932 6.47500072939838 5.06250057028252 3.48750039286129 3.78750042665581 5.60000063083104 3.48750039286129 5.68750064068777 15.5500017516826 6.18750069701197 5.68750064068777 5.60000063083104 5.30000059703651 3.71250041820718 9.20000103636528 7.08750079839553 6.40000072094975 3.78750042665581 3.85000043369634 3.78750042665581 5.17500058295547 2046 7.1734350642248 4.28396034483477 5.91714170796827 11.9347868844371 5.99251930934365 6.40709611690831 7.38700493478841 7.91464814441615 8.01515161291667 4.07039047427116 5.84176410659288 5.13823982708922 9.76139937811325 6.69604358884732 6.11814864496931 9.3091337698609 9.24631910204808 5.76638650521748 5.82920117303031 9.24631910204808 6.1935262463447 6.35684438265805 4.77391475377482 8.54279482254441 6.33171851553292 7.34931613410071 5.65332010315439 5.65332010315439 6.11814864496931 4.94979582365074 4.07039047427116 3.58043606533112 4.43471554758556 5.6156313024667 4.64828541814917 3.80656886945729 9.03274923148447 4.07039047427116 3.80656886945729 5.6156313024667 6.24377798059496 4.44727848114812 3.99501287289577 3.50505846395573 4.62315955102404 6.03020811003135 6.53272545253397 6.16840037921957 7.1734350642248 6.43222198403344 6.40709611690831 2.81409711801463 4.56034488321121 8.54279482254441 5.15080276065178 6.63322892103449 5.11311395996409 5.35180969765282 5.32668383052769 5.9422675750934 4.59803368389891 4.93723289008817 3.80656886945729 5.21361742846461 4.07039047427116 5.66588303671696 6.20608917990727 5.07542515927639 3.80656886945729 11.5830247446852 5.75382357165492 3.93219820508294 4.07039047427116 7.19856093134993 6.60810305390936 5.13823982708922 7.34931613410071 6.1935262463447 3.93219820508294 6.60810305390936 9.03274923148447 5.97995637578109 6.45734785115857 3.80656886945729 4.59803368389891 11.2563884720585 5.23874329558974 8.16590681566746 6.4824737182837 5.9045787744057 5.71613477096722 4.25883447770964 6.59554012034679 6.06789691071905 6.38197024978318 4.04526460714603 7.34931613410071 6.25634091415753 5.6156313024667 6.60810305390936 5.16336569421435 4.6734112852743 5.28899502984 6.43222198403344 5.56537956821643 3.58043606533112 3.93219820508294 4.59803368389891 5.05029929215126 4.51009314896095 0.678398412378527 6.33171851553292 3.80656886945729 6.69604358884732 6.16840037921957 6.89705052584836 5.71613477096722 9.74883644455069 10.6910564617431 13.46746477907 4.51009314896095 6.65835478815962 3.80656886945729 6.60810305390936 5.21361742846461 6.2312150470324 6.1935262463447 5.36437263121539 5.23874329558974 5.75382357165492 4.45984141471069 5.65332010315439 3.80656886945729 6.53272545253397 4.97492169077587 5.05029929215126 5.35180969765282 7.1357462635371 7.21112386491249 6.99755399434888 5.08798809283895 5.79151237234261 5.6156313024667 8.81917936092085 5.05029929215126 4.89954408940048 6.5201625189714 6.15583744565701 6.25634091415753 4.88698115583791 6.13071157853188 5.65332010315439 11.2563884720585 3.93219820508294 4.59803368389891 3.58043606533112 5.6156313024667 13.8066639852593 5.05029929215126 5.91714170796827 8.22872148348029 5.91714170796827 5.6156313024667 7.11062039641197 4.88698115583791 7.09805746284941 6.50759958540883 5.08798809283895 3.50505846395573 3.80656886945729 5.62819423602927 3.50505846395573 5.71613477096722 15.6282893518313 6.21865211346983 5.71613477096722 5.62819423602927 5.32668383052769 3.7311912680819 9.24631910204808 7.12318332997453 6.43222198403344 3.80656886945729 3.86938353727012 3.80656886945729 5.20105449490204 2047 7.39894817937095 4.41863630326707 6.10316040715187 12.3099838360813 6.18090767348501 6.60851763831731 7.61923210064819 8.16346296498021 8.26712598675773 4.19835238198982 6.02541314081873 5.29977198837604 10.0682709901423 6.9065488259277 6.31048645070692 9.60178739214339 9.53699800353244 5.94766587448558 6.01245526309653 9.53699800353244 6.38823371704007 6.55668612742855 4.92399353443251 8.81135685108974 6.53077037198417 7.58035846748162 5.83104497498586 5.83104497498586 6.31048645070692 5.10540382254318 4.19835238198982 3.69299515082438 4.57413083593336 5.79217134181929 4.7944147572106 3.92623694982381 9.31671408225519 4.19835238198982 3.92623694982381 5.79217134181929 6.44006522792883 4.58708871365554 4.12060511565668 3.61524788449124 4.76849900176622 6.21978130665159 6.73809641553922 6.36231796159568 7.39894817937095 6.63443339376169 6.60851763831731 2.90256460977074 4.70370961315526 8.81135685108974 5.31272986609823 6.84175943731675 5.27385623293166 5.52005590965328 5.4941401542089 6.12907616259625 4.74258324632183 5.09244594482099 3.92623694982381 5.37751925470918 4.19835238198982 5.84400285270805 6.40119159476226 5.23498259976509 3.92623694982381 11.9471632598599 5.93470799676339 4.05581572704572 4.19835238198982 7.42486393481533 6.81584368187237 5.29977198837604 7.58035846748162 6.38823371704007 4.05581572704572 6.81584368187237 9.31671408225519 6.16794979576282 6.66034914920607 3.92623694982381 4.74258324632183 11.610258439083 5.40343501015356 8.42262051942402 6.68626490465045 6.09020252942968 5.89583436359682 4.39272054782268 6.80288580415017 6.25865493981816 6.58260188287293 4.17243662654544 7.58035846748162 6.45302310565102 5.79217134181929 6.81584368187237 5.32568774382042 4.82033051265498 5.45526652104233 6.63443339376169 5.74033983093052 3.69299515082438 4.05581572704572 4.74258324632183 5.2090668443207 4.6518781022665 0.699725396998303 6.53077037198417 3.92623694982381 6.9065488259277 6.36231796159568 7.11387486948275 5.89583436359682 10.0553131124201 11.0271539415844 13.8908449181885 4.6518781022665 6.86767519276113 3.92623694982381 6.81584368187237 5.37751925470918 6.42710735020664 6.38823371704007 5.53301378737547 5.40343501015356 5.93470799676339 4.60004659137773 5.83104497498586 3.92623694982381 6.73809641553922 5.13131957798756 5.2090668443207 5.52005590965328 7.36007454620438 7.43782181253752 7.21753789126028 5.24794047748727 5.97358162992996 5.79217134181929 9.09643016097795 5.2090668443207 5.05357231165441 6.72513853781703 6.34936008387349 6.45302310565102 5.04061443393222 6.32344432842911 5.83104497498586 11.610258439083 4.05581572704572 4.74258324632183 3.69299515082438 5.79217134181929 14.2407076166877 5.2090668443207 6.10316040715187 8.48740990803498 6.10316040715187 5.79217134181929 7.33415879076 5.04061443393222 7.32120091303781 6.71218066009484 5.24794047748727 3.61524788449124 3.92623694982381 5.80512921954148 3.61524788449124 5.89583436359682 16.1195998864054 6.41414947248445 5.89583436359682 5.80512921954148 5.4941401542089 3.84848968349067 9.53699800353244 7.34711666848218 6.63443339376169 3.92623694982381 3.99102633843477 3.92623694982381 5.36456137698699 2048 7.42788482354586 4.43591720635576 6.12702933781103 12.3581271144809 6.20508066695512 6.63436297724762 7.64903025612078 8.19538956012941 8.2994579989882 4.21477177378084 6.04897800866695 5.32049893665544 10.1076471241596 6.93355973896663 6.33516621552861 9.63933914929507 9.57429637500833 5.97092667952285 6.0359694538096 9.57429637500833 6.4132175446727 6.58232875781822 4.94325084579234 8.84581730299682 6.55631164810353 7.61000459154874 5.85384968580672 5.85384968580672 6.33516621552861 5.12537061379522 4.21477177378084 3.70743813434426 4.59201986464394 5.81482402123468 4.81316529721886 3.94159212177653 9.35315094243341 4.21477177378084 3.94159212177653 5.81482402123468 6.46525176410209 4.60502841950129 4.13672044463675 3.62938680520017 4.78714818750417 6.24410633152717 6.7644485258211 6.387200434958 7.42788482354586 6.66038008696231 6.63436297724762 2.91391628804601 4.72210541321742 8.84581730299682 5.33350749151279 6.86851696467989 5.29448182694075 5.54164436923036 5.51562725951567 6.15304644752573 4.76113107778947 5.11236205893787 3.94159212177653 5.39855026579953 4.21477177378084 5.86685824066407 6.42622609953005 5.2554561623687 3.94159212177653 11.9938875784751 5.95791812466551 4.07167767035001 4.21477177378084 7.45390193326056 6.84249985496519 5.32049893665544 7.61000459154874 6.4132175446727 4.07167767035001 6.84249985496519 9.35315094243341 6.19207211209777 6.68639719667701 3.94159212177653 4.76113107778947 11.6556651521841 5.42456737551423 8.45556065727637 6.7124143063917 6.11402078295369 5.91889246009346 4.40990009664106 6.82949130010784 6.28313199609921 6.60834586753292 4.18875466406614 7.61000459154874 6.47826031895944 5.81482402123468 6.84249985496519 5.34651604637014 4.83918240693356 5.47660159494362 6.66038008696231 5.76278980180528 3.70743813434426 4.07167767035001 4.76113107778947 5.229439052654 4.67007119378803 0.702461962296806 6.55631164810353 3.94159212177653 6.93355973896663 6.387200434958 7.1416966166842 5.91889246009346 10.0946385693023 11.0702801836034 13.9451708070773 4.67007119378803 6.89453407439458 3.94159212177653 6.84249985496519 5.39855026579953 6.45224320924474 6.4132175446727 5.55465292408771 5.42456737551423 5.95791812466551 4.61803697435863 5.85384968580672 3.94159212177653 6.7644485258211 5.15138772350991 5.229439052654 5.54164436923036 7.38885915897382 7.46691048811791 7.24576505554299 5.26846471722605 5.99694378923755 5.81482402123468 9.13200550985849 5.229439052654 5.07333639436582 6.75143997096375 6.37419188010065 6.47826031895944 5.06032783950848 6.34817477038596 5.85384968580672 11.6556651521841 4.07167767035001 4.76113107778947 3.70743813434426 5.81482402123468 14.2964017882258 5.229439052654 6.12702933781103 8.52060343156312 6.12702933781103 5.81482402123468 7.36284204925912 5.06032783950848 7.34983349440177 6.7384314161064 5.26846471722605 3.62938680520017 3.94159212177653 5.82783257609203 3.62938680520017 5.91889246009346 16.1826422425412 6.4392346543874 5.91889246009346 5.82783257609203 5.51562725951567 3.86354079263244 9.57429637500833 7.37585060411647 6.66038008696231 3.94159212177653 4.00663489606327 3.94159212177653 5.38554171094218 2049 7.47481882926998 4.46394609593881 6.16574372782165 12.4362134637592 6.24428823390854 6.6762830173865 7.69736159651619 8.24717313912449 8.35189914724036 4.2414033286926 6.08719922173475 5.35411716492368 10.1715135382535 6.97737029071961 6.37519574405338 9.70024650173214 9.63479274665973 6.00865471564784 6.07410847072026 9.63479274665973 6.45374025014028 6.62392001332856 4.97448538550367 8.90171068984866 6.5977385112996 7.65808934347274 5.8908379565175 5.8908379565175 6.37519574405338 5.15775589970643 4.2414033286926 3.73086403912775 4.62103510811261 5.85156570347405 4.84357787535883 3.96649755738845 9.41224997941351 4.2414033286926 3.96649755738845 5.85156570347405 6.50610325419821 4.6341258591271 4.1628588226057 3.65231953304085 4.81739637332987 6.283560486952 6.80719052753133 6.42755874811131 7.47481882926998 6.70246451941546 6.6762830173865 2.93232822724427 4.75194261825745 8.90171068984866 5.36720791593816 6.9119165356472 5.32793566289471 5.5766599321699 5.55047843014093 6.19192522985061 4.7912148713009 5.14466514869195 3.96649755738845 5.43266167101058 4.2414033286926 5.90392870753198 6.46683100115476 5.28866340985126 3.96649755738845 12.0696724353536 5.99556396463336 4.09740506753328 4.2414033286926 7.50100033129895 6.88573503361823 5.35411716492368 7.65808934347274 6.45374025014028 4.09740506753328 6.88573503361823 9.41224997941351 6.23119748289406 6.72864602144443 3.96649755738845 4.7912148713009 11.7293129089771 5.45884317303954 8.50898815941416 6.75482752347339 6.15265297680716 5.95629171158991 4.43776459390985 6.87264428260375 6.32283273999545 6.65010151535753 4.21522182666363 7.65808934347274 6.5191940052127 5.85156570347405 6.88573503361823 5.38029866695264 4.8697593773878 5.51120617709748 6.70246451941546 5.79920269941611 3.73086403912775 4.09740506753328 4.7912148713009 5.26248190782229 4.69957961419952 0.706900554782099 6.5977385112996 3.96649755738845 6.97737029071961 6.42755874811131 7.18682230695134 5.95629171158991 10.1584227872391 11.1402291133253 14.0332850875261 4.69957961419952 6.93809803767616 3.96649755738845 6.88573503361823 5.43266167101058 6.49301250318373 6.45374025014028 5.58975068318438 5.45884317303954 5.99556396463336 4.64721661014158 5.8908379565175 3.96649755738845 6.80719052753133 5.1839374017354 5.26248190782229 5.5766599321699 7.43554657622653 7.51409108231343 7.29154831506721 5.30175416086574 6.03483621767681 5.85156570347405 9.18970721216729 5.26248190782229 5.1053928956485 6.79409977651685 6.41446799709683 6.5191940052127 5.09230214463401 6.38828649506786 5.8908379565175 11.7293129089771 4.09740506753328 4.7912148713009 3.73086403912775 5.85156570347405 14.3867353649172 5.26248190782229 6.16574372782165 8.57444191448658 6.16574372782165 5.85156570347405 7.40936507419756 5.09230214463401 7.39627432318308 6.78100902550236 5.30175416086574 3.65231953304085 3.96649755738845 5.86465645448853 3.65231953304085 5.95629171158991 16.2848942620173 6.47992175216925 5.95629171158991 5.86465645448853 5.55047843014093 3.88795305130155 9.63479274665973 7.42245582521204 6.70246451941546 3.96649755738845 4.03195131246086 3.96649755738845 5.4195709199961 2050 7.52587717674726 4.49443803374924 6.20786015805246 12.5211616776005 6.28694117917415 6.72188679534343 7.74994006992537 8.30350721777718 8.40894857927277 4.27037514057112 6.12877913693078 5.3906896064617 10.2409922352585 7.02503070964324 6.41874288104363 9.7665061085284 9.70060525759367 6.04969811580909 6.11559896674383 9.70060525759367 6.49782390216532 6.66916611459564 5.00846467104021 8.96251572712457 6.64280577422175 7.71039955936453 5.93107658412656 5.93107658412656 6.41874288104363 5.19298705365748 4.27037514057112 3.75634850328015 4.65260007599261 5.89153607356572 4.87666296917073 3.99359156664522 9.47654236441555 4.27037514057112 3.99359156664522 5.89153607356572 6.55054458291311 4.66578024617956 4.19129411944944 3.67726748215847 4.85030262879683 6.326481689735 6.85368849721291 6.47146356179142 7.52587717674726 6.74824713571733 6.72188679534343 2.95235812187633 4.78440177786209 8.96251572712457 5.40386977664864 6.9591298587085 5.3643292660878 5.61475249963981 5.58839215926591 6.23422049842636 4.82394228842293 5.17980688347053 3.99359156664522 5.46977062758338 4.27037514057112 5.94425675431351 6.51100407235227 5.32478875552696 3.99359156664522 12.152116912366 6.03651794562214 4.1253932685147 4.27037514057112 7.55223751712115 6.9327695183346 5.3906896064617 7.71039955936453 6.49782390216532 4.1253932685147 6.9327695183346 9.47654236441555 6.2737610089872 6.77460747609123 3.99359156664522 4.82394228842293 11.8094324875053 5.49613096795728 8.56711062151614 6.80096781646512 6.19467998786552 5.9969774350613 4.46807769337534 6.91958934814765 6.36602220029584 6.69552645496954 4.24401480019723 7.71039955936453 6.56372475310006 5.89153607356572 6.9327695183346 5.41704994683559 4.90302330954462 5.54885164870507 6.74824713571733 5.83881539281792 3.75634850328015 4.1253932685147 4.82394228842293 5.29842841515306 4.7316810971143 0.711729190095187 6.64280577422175 3.99359156664522 7.02503070964324 6.47146356179142 7.2359134326344 5.9969774350613 10.2278120650716 11.2163248290927 14.1291424404082 4.7316810971143 6.98549019908239 3.99359156664522 6.9327695183346 5.46977062758338 6.53736441272616 6.49782390216532 5.62793266982676 5.49613096795728 6.03651794562214 4.6789604163665 5.93107658412656 3.99359156664522 6.85368849721291 5.21934739403137 5.29842841515306 5.61475249963981 7.48633666618641 7.5654176873081 7.34135479412998 5.3379689257139 6.07605845618299 5.89153607356572 9.25247947123743 5.29842841515306 5.14026637290968 6.84050832702597 6.45828339160447 6.56372475310006 5.12708620272274 6.43192305123058 5.93107658412656 11.8094324875053 4.1253932685147 4.82394228842293 3.75634850328015 5.89153607356572 14.4850070354558 5.29842841515306 6.20786015805246 8.63301147245088 6.20786015805246 5.89153607356572 7.45997632581252 5.12708620272274 7.44679615562557 6.82732815683902 5.3379689257139 3.67726748215847 3.99359156664522 5.90471624375267 3.67726748215847 5.9969774350613 16.3961317125632 6.52418424253922 5.9969774350613 5.90471624375267 5.58839215926591 3.91451054552353 9.70060525759367 7.47315649599946 6.74824713571733 3.99359156664522 4.05949241757996 3.99359156664522 5.45659045739643 Utility CEA HEA MEA South of Railbelt (Avg) GVEA Source: Utility COPA/SFPPR Filings Avoided Cost ($/kWh) 0.06207 0.08588 0.08704 0.07833 0.16009 Effective Date 4/1/2025 4/1/2025 4/1/2025 4/1/2025 Utility CEA MEA Average Source: MEA (TA 504-18) & CEA (TA 481-8) Hilcorp Contracts 2022 ($/Mcf) 7.61 7.56 7.585 2023 ($/Mcf) 7.69 7.62 7.655 MEA 2024 ($/Mcf) 7.78 7.71 7.745 2025 ($/Mcf) 7.86 7.8 7.83 2026 ($/Mcf) 7.95 7.89 7.92 2027 ($/Mcf) 8.04 7.98 8.01 CEA Amount 8250533.07 986068000 8.36710355675268E-03 Source: CEA 2024 Annual Report to RCA - Southcentral Power Plant Operating Statistics Unit Mcf kWh mcf/kwh Carbon Prices Source: Interagency Working Group on Social Cost of Greenhouses Gases United States Government Technical Support Document: Social Cost of Carbon, Methane and Nitrouse Oxide Interim Estimates Under Executive Order 13990 Technical Support Document: Social Cost of Carbon, Methane, (whitehouse.gov) Real 2023$ per metric ton CO2-equivalent Low Mid High Metric Tons CO2 per gallon: Real 2023$ per metric ton CO2-equivalent Low Mid High Metric Tons CO2 per Mcf: Real 2023$ per metric ton CO2-equivalent Low Mid High Assumptions and workup Source: Technical Support Document: Social Cost of Carbon, Methane, (whitehouse.gov) CO2 Conversion Factors Source: 1 Metric Ton = Fuel Middle Distillate Fuels (No. 1, No. 2, No. 4 fuel oil, diesel, home heating oil) Natural Gas (National Average) Assumptions Source Source: Interagency Working Group on Social Cost of Greenhouses Gases United States Government Technical Support Document: Social Cost of Carbon, Methane and Nitrouse Oxide Interim Estimates Under Executive Order 13990 Technical Support Document: Social Cost of Carbon, Methane, (whitehouse.gov) CPI-rate Annual CPI-U CPI multiplier 0.01019 0.05291 Low Mid High US Energy Information Association Carbon Dioxide Emissions Coefficients U.S. Energy Information Administration - EIA - Independent Statistics and Analysis 1000 Emission Factor 74.14 10.19 52.91 5.291 3 2023 15.26 55.59 82.84 3 0.51765 0.7714 0.74284 2.70606 4.03256 Multiplier to 2023$ Benchmark price is: Increasing at In 2023 Dollars Benchmark price is: Increasing at In 2023 Dollars Benchmark price is: Increasing at In 2023 Dollars Kg Units Kg CO2/MMBtu Kg CO2/gallon Kg CO2/MMBtu Kg CO2/therm 2013 0.015 234.719 1.19345259650902 pg 6 4 2024 15.7178 57.2577 85.3252 0.152184186661773 0.554385251410745 0.826142727592482 0.795555955100855 2.89809669358169 4.31873232769035 1.09 14 0.03 15.26 51 0.03 55.59 76 0.03 82.84 pg 6 Metric Ton CO2/unit 0.07414 0.01019 0.05291 0.005291 pg 6 2014 0.8 236.252 1.18570848077477 5 2025 16.189334 58.975431 87.884956 0.156749712261626 0.571016808953067 0.850927009420257 0.81942263375388 2.98503959438914 4.44829429752107 2015 0.7 237.761 1.17818313348278 6 2026 16.67501402 60.74469393 90.52150468 0.161452203629475 0.588147313221659 0.876454819702864 0.844005312766497 3.07459078222081 4.5817431264467 2016 0.021 242.637 1.15450652620993 7 2027 17.1752644406 62.5670347479 93.2371498204 0.166295769738359 0.605791732618309 0.90274846429395 0.869325472149492 3.16682850568743 4.7191954202401 2017 0.021 247.805 1.13042916809588 8 2028 17.690522373818 64.444045790337 96.034264315012 0.17128464283051 0.623965484596858 0.929830918222769 0.895405236313977 3.26183336085806 4.8607712828473 2018 0.019 252.551 1.10918586740896 9 2029 18.2212380450325 66.3773671640471 98.9152922444624 0.176423182115425 0.642684449134764 0.957725845769452 0.922267393403396 3.3596883616838 5.00659442133272 2019 0.023 258.263 1.08465401548034 10 2030 18.7678751863835 68.3686881789685 101.882751011796 0.181715877578888 0.661964982608807 0.986457621142535 0.949935415205498 3.46047901253431 5.1567922539727 2020 0.014 261.564 1.07096542337631 11 2031 19.330911441975 70.4197488243376 104.93923354215 0.187167353906255 0.681823932087071 1.01605134977681 0.978433477661663 3.56429338291034 5.31149602159188 2021 7.09654233763054E-02 280.126 1 12 2032 19.9108387852343 72.5323412890677 108.087410548415 0.192782374523442 0.702278650049683 1.04653289027012 1.00778648199151 3.67122218439765 5.47084090223964 2022 0.03 288.52978 0.970873786407767 13 2033 20.5081639487913 74.7083115277398 111.330032864867 0.198565845759146 0.723347009551174 1.07792887697822 1.03802007645126 3.78135884992958 5.63496612930683 2023 0.024 295.45449472 0.948118932038835 14 2034 21.123408867255 76.949560873572 114.669933850813 0.20452282113192 0.745047419837709 1.11026674328757 1.0691606787448 3.89479961542747 5.80401511318603 2024 2.39999999999958E-02 302.545402593279 0.925897394569179 15 2035 21.7571111332727 79.2580476997791 118.110031866338 0.210658505765878 0.76739884243284 1.14357474558619 1.10123549910714 4.0116436038903 5.97813556658162 2025 0.023999999999995 309.806492255516 0.904196674383968 16 2036 22.4098244672709 81.6357891307725 121.653332822328 0.216978260938854 0.790420807705825 1.17788198795378 1.13427256408035 4.131992912007 6.15747963357906 2026 2.39999999999939E-02 317.241848069646 0.883004564828099 17 2037 23.082119201289 84.0848628046957 125.302932806997 0.22348760876702 0.814133431937 1.21321844759239 1.16830074100277 4.25595269936721 6.34220402258644 2027 2.39999999999931E-02 324.855652423316 0.862309145339946 18 2038 23.7745827773277 86.6074086888366 129.062020791207 0.23019223703003 0.83855743489511 1.24961500102016 1.20334976323285 4.38363128034823 6.53247014326403 2028 2.39999999999922E-02 332.652188081473 0.842098774746048 19 2039 24.4878202606475 89.2056309495017 132.933881414944 0.237098004140931 0.863714157941963 1.28710345105077 1.23945025612983 4.51514021875868 6.72844424756195 2029 2.39999999999913E-02 340.635840595425 0.822362084712944 20 2040 25.2224548684669 91.8817998779867 136.921897857392 0.244210944265159 0.889625582680223 1.32571655458229 1.27663376381373 4.65059442532144 6.93029757498881 2030 2.39999999999905E-02 348.811100769712 0.803087973352492 21 2041 25.9791285145209 94.6382538743263 141.029554793114 0.251537272593114 0.916314350160629 1.36548805121976 1.31493277672814 4.79011225808108 7.13820650223847 2031 2.39999999999897E-02 357.182567188182 0.784265598977051 22 2042 26.7585023699566 97.4774014905561 145.260441436907 0.259083390770907 0.943803780665448 1.40645269275635 1.35438076002998 4.93381562582351 7.35235269730563 2032 2.39999999999888E-02 365.754948800694 0.765884374001035 23 2043 27.5612574410553 100.401723535273 149.618254680014 0.266855892494035 0.972117894085412 1.44864627353904 1.39501218283088 5.08183009459822 7.5729232782248 2033 2.39999999999878E-02 374.533067571906 0.747933958985394 24 2044 28.3880951642869 103.413775241331 154.106802320415 0.274861569268856 1.00128143090797 1.49210566174522 1.43686254831581 5.23428499743617 7.80011097657154 2034 2.39999999999869E-02 383.521861193627 0.730404256821684 25 2045 29.2397380192155 106.516188498571 158.730006390027 0.283107416346921 1.03131987383521 1.53686883159757 1.47996842476529 5.39131354735925 8.03411430586869 2035 0.023999999999986 392.726385862269 0.713285407052435 26 2046 30.116930159792 109.711674153528 163.491906581728 0.291600638837329 1.06225947005027 1.5829748965455 1.52436747750824 5.55305295378003 8.27513773504475 2036 2.39999999999852E-02 402.151819122957 0.696567780324654 27 2047 31.0204380645858 113.003024378134 168.39666377918 0.300348658002449 1.09412725415178 1.63046414344186 1.57009850183349 5.71964454239343 8.52339186709609 2037 2.39999999999842E-02 411.803462781902 0.680241972973305 28 2048 31.9510512065233 116.393115109478 173.448563692555 0.309359117742522 1.12695107177633 1.67937806774512 1.6172014568885 5.89123387866523 8.77909362310898 2038 2.39999999999834E-02 421.686745888661 0.664298801731754 29 2049 32.909582742719 119.884908562762 178.652020603332 0.309359117742522 1.12695107177633 1.67937806774512 1.6172014568885 5.89123387866523 8.77909362310898 2039 2.39999999999825E-02 431.807227789981 0.648729298566177 30 2050 33.8968702250006 123.481455819645 184.011581221432 0.309359117742522 1.12695107177633 1.67937806774512 1.6172014568885 5.89123387866523 8.77909362310898 2040 2.39999999999816E-02 442.170601256933 0.633524705631044 31 2051 34.9137763317506 127.185899494234 189.531928658075 0.309359117742522 1.12695107177633 1.67937806774512 1.6172014568885 5.89123387866523 8.77909362310898 2041 2.39999999999816E-02 452.782695687091 0.618676470342827 32 2052 35.9611896217031 131.001476479062 195.217886517817 0.309359117742522 1.12695107177633 1.67937806774512 1.6172014568885 5.89123387866523 8.77909362310898 2042 2.39999999999815E-02 463.649480383573 0.604176240569178 33 2053 37.0400253103542 134.931520773433 201.074423113352 0.309359117742522 1.12695107177633 1.67937806774512 1.6172014568885 5.89123387866523 8.77909362310898 2043 2.39999999999816E-02 474.77706791277 0.590015859930849 34 2054 38.1512260696649 138.979466396636 207.106655806752 0.309359117742522 1.12695107177633 1.67937806774512 1.6172014568885 5.89123387866523 8.77909362310898 2044 2.39999999999816E-02 486.171717542668 0.57618736321373 35 2055 39.2957628517548 143.148850388535 213.319855480955 0.309359117742522 1.12695107177633 1.67937806774512 1.6172014568885 5.89123387866523 8.77909362310898 2045 2.39999999999816E-02 497.839838763683 0.562682971888418 36 2056 40.4746357373075 147.443315900191 219.719451145383 0.309359117742522 1.12695107177633 1.67937806774512 1.6172014568885 5.89123387866523 8.77909362310898 2046 2.39999999999815E-02 509.787994894002 0.549495089734793 37 2057 41.6888748094267 151.866615377197 226.311034679745 0.309359117742522 1.12695107177633 1.67937806774512 1.6172014568885 5.89123387866523 8.77909362310898 2047 2.39999999999816E-02 522.022906771449 0.536616298569144 38 2058 42.9395410537095 156.422613838513 233.100365720137 0.309359117742522 1.12695107177633 1.67937806774512 1.6172014568885 5.89123387866523 8.77909362310898 2048 2.39999999999815E-02 534.551456533954 0.524039354071439 39 2059 44.2277272853208 161.115292253669 240.093376691741 0.309359117742522 1.12695107177633 1.67937806774512 1.6172014568885 5.89123387866523 8.77909362310898 2049 2.39999999999816E-02 547.380691490759 0.511757181710399 40 2060 45.5545591038804 165.948751021279 247.296177992494 0.309359117742522 1.12695107177633 1.67937806774512 1.6172014568885 5.89123387866523 8.77909362310898 2050 2.39999999999816E-02 547.380691490759 0.511757181710399 41 2061 46.9211958769968 170.927213551917 254.715063332269 0.309359117742522 1.12695107177633 1.67937806774512 1.6172014568885 5.89123387866523 8.77909362310898 2051 2.39999999999816E-02 547.380691490759 0.511757181710399 42 2062 48.3288317533067 176.055029958474 262.356515232237 0.309359117742522 1.12695107177633 1.67937806774512 1.6172014568885 5.89123387866523 8.77909362310898 2052 2.39999999999816E-02 547.380691490759 0.511757181710399 43 2063 49.7786967059059 181.336680857229 270.227210689204 0.309359117742522 1.12695107177633 1.67937806774512 1.6172014568885 5.89123387866523 8.77909362310898 2053 2.39999999999816E-02 547.380691490759 0.511757181710399 44 2064 51.2720576070831 186.776781282946 278.33402700988 0.309359117742522 1.12695107177633 1.67937806774512 1.6172014568885 5.89123387866523 8.77909362310898 2054 2.39999999999816E-02 547.380691490759 0.511757181710399 45 2065 52.8102193352956 192.380084721434 286.684047820176 0.309359117742522 1.12695107177633 1.67937806774512 1.6172014568885 5.89123387866523 8.77909362310898 2055 2.39999999999816E-02 547.380691490759 0.511757181710399 46 2066 54.3945259153545 198.151487263077 295.284569254782 0.309359117742522 1.12695107177633 1.67937806774512 1.6172014568885 5.89123387866523 8.77909362310898 2056 2.39999999999816E-02 547.380691490759 0.511757181710399 47 2067 56.0263616928151 204.096031880969 304.143106332425 0.309359117742522 1.12695107177633 1.67937806774512 1.6172014568885 5.89123387866523 8.77909362310898 2057 2.39999999999816E-02 547.380691490759 0.511757181710399 48 2068 57.7071525435996 210.218912837398 313.267399522398 0.309359117742522 1.12695107177633 1.67937806774512 1.6172014568885 5.89123387866523 8.77909362310898 2058 2.39999999999816E-02 547.380691490759 0.511757181710399 49 2069 59.4383671199076 216.52548022252 322.66542150807 0.309359117742522 1.12695107177633 1.67937806774512 1.6172014568885 5.89123387866523 8.77909362310898 2059 2.39999999999816E-02 547.380691490759 0.511757181710399 50 2070 61.2215181335048 223.021244629196 332.345384153312 0.309359117742522 1.12695107177633 1.67937806774512 1.6172014568885 5.89123387866523 8.77909362310898 2060 2.39999999999816E-02 547.380691490759 0.511757181710399 51 2071 63.0581636775099 229.711881968072 342.315745677911 0.309359117742522 1.12695107177633 1.67937806774512 1.6172014568885 5.89123387866523 8.77909362310898 2061 2.39999999999816E-02 547.380691490759 0.511757181710399 52 2072 64.9499085878352 236.603238427114 352.585218048249 0.309359117742522 1.12695107177633 1.67937806774512 1.6172014568885 5.89123387866523 8.77909362310898 2062 2.39999999999816E-02 547.380691490759 0.511757181710399 53 2073 66.8984058454703 243.701335579927 363.162774589696 0.309359117742522 1.12695107177633 1.67937806774512 1.6172014568885 5.89123387866523 8.77909362310898 2063 2.39999999999816E-02 547.380691490759 0.511757181710399 54 2074 68.9053580208344 251.012375647325 374.057657827387 0.309359117742522 1.12695107177633 1.67937806774512 1.6172014568885 5.89123387866523 8.77909362310898 2064 2.39999999999816E-02 547.380691490759 0.511757181710399 55 2075 70.9725187614594 258.542746916745 385.279387562208 0.309359117742522 1.12695107177633 1.67937806774512 1.6172014568885 5.89123387866523 8.77909362310898 2065 2.39999999999816E-02 547.380691490759 0.511757181710399 56 2076 73.1016943243032 266.299029324247 396.837769189075 0.309359117742522 1.12695107177633 1.67937806774512 1.6172014568885 5.89123387866523 8.77909362310898 2066 2.39999999999816E-02 547.380691490759 0.511757181710399 57 2077 75.2947451540323 274.288000203975 408.742902264747 0.309359117742522 1.12695107177633 1.67937806774512 1.6172014568885 5.89123387866523 8.77909362310898 2067 2.39999999999816E-02 547.380691490759 0.511757181710399 58 2078 77.5535875086533 282.516640210094 421.005189332689 0.309359117742522 1.12695107177633 1.67937806774512 1.6172014568885 5.89123387866523 8.77909362310898 2068 2.39999999999816E-02 547.380691490759 0.511757181710399 59 2079 79.8801951339129 290.992139416397 433.63534501267 0.309359117742522 1.12695107177633 1.67937806774512 1.6172014568885 5.89123387866523 8.77909362310898 2069 2.39999999999816E-02 547.380691490759 0.511757181710399 60 2080 82.2766009879303 299.721903598889 446.64440536305 0.309359117742522 1.12695107177633 1.67937806774512 1.6172014568885 5.89123387866523 8.77909362310898 2070 2.39999999999816E-02 547.380691490759 0.511757181710399 61 2081 84.7448990175682 308.713560706856 460.043737523942 0.309359117742522 1.12695107177633 1.67937806774512 1.6172014568885 5.89123387866523 8.77909362310898 2071 2.39999999999816E-02 547.380691490759 0.511757181710399 62 2082 30.4787308120712 111.029662243973 165.455967265529 0.309359117742522 1.12695107177633 1.67937806774512 1.6172014568885 5.89123387866523 8.77909362310898 2072 2.39999999999816E-02 547.380691490759 0.511757181710399 63 2083 30.4787308120712 111.029662243973 165.455967265529 0.309359117742522 1.12695107177633 1.67937806774512 1.6172014568885 5.89123387866523 8.77909362310898 2073 2.39999999999816E-02 547.380691490759 0.511757181710399 64 2084 30.4787308120712 111.029662243973 165.455967265529 0.309359117742522 1.12695107177633 1.67937806774512 1.6172014568885 5.89123387866523 8.77909362310898 2074 2.39999999999816E-02 547.380691490759 0.511757181710399 65 2085 30.4787308120712 111.029662243973 165.455967265529 0.309359117742522 1.12695107177633 1.67937806774512 1.6172014568885 5.89123387866523 8.77909362310898 2075 2.39999999999816E-02 547.380691490759 0.511757181710399 Please use this worksheet for reference and to input additional data regarding biomass fuel used in the project being analyzed. Note: Below please enter the values being used in the project analysis. If values other than the estimates provided below are not used, please include source and assumptions being used in the 'Notes' column. Use the blank space in 'Calc' sheet for your calculations. Biomass Fuel Type *Please enter HHV for High Heating Value or LHV for Low Heating Value Other Sources: 1. "Forest Products Measurements and Conversion Factors with Special Emphasis on the U.S. Pacific Northwest.: U of Washington, David Briggs. Most current edition. 2. "Conversion Factors for the Forest-Products Industry in Western Canada" by Jock Dobie and D.M. Wright. August 1975 (non-metric units). 3. "Wood handbook: Wood as an Engineering Material" USDA, Forest Products Laboratory. Ag Handbook No. 72. Most recent editions. 4. "Canadian Woods: Their Properties and Uses. U of Toronto Press in coop with Canadian Forestry Service. Most recent edition. 5. "Use of Wood Energy in Remote Interior Alaskan Communities" Reid, Collins Alaska Inc. September 1981. 6. "Matanuska-Susitna Borough: Forest Inventory Report" Dec 2006. Sanders Forestry Consulting. 7. Kenai Conversion Tables. Cal Kerr 2002. [I'll send a copy to you.] 8. U of A. Cooperative Extension. Axel Carlson. Original author. Now Seifert. Comparative Unit Fuel Costs for Equivalent Dollar Net Heat Output" 9. Alaska Power Authority: Wood Cost Model Adapted by Kerr. Units Source: California Energy Commission http://www.consumerenergycenter.org/home/heating_cooling/firewood.html Cal Kerr, Northern Economics Wood Heating and Weights Values Species Alder, Red Aspen Birch Cottonwood Juniper, western Pine, Lodgepole (Shore Pine) Spruce, Sitka Willow, Black *British thermal unit (Btu) values based on specific gravity of 80 cubic feet per cord. 8000 to 8500 Btu per pound for non resinous woods. 8600 to 9700 Btu per pound for resinous woods. **Weights: All moisture content based on "wet" wood basis Moisture Content % MMBtu/Cord* 18.4 - 19.5 17.0 - 18.0 25.9-27.5 15.8 - 16.8 23.4 - 26.4 19.7 - 22.3 19.3 - 21.7 17.5 - 18.6 Lower value of range assumes 70 cubic feet of wood per cord. Higher value of range assumes 90 cubic feet of wood per cord. Dry weight at 12 percent moisture content Green weight at 40 to 60 percent moisture content Heating Value MMBtu per unit Cord Weight (pounds)** DRY 2000 - 2600 1860 - 2400 2840 - 3650 1730 - 2225 2400 - 3050 2000 - 2580 1960 - 2520 1910 - 2450 HHV or LHV* Cord Weight (pounds)** GREEN 3200 - 4100 3020 - 3880 4630 - 5960 2700 - 3475 4225 - 5410 3320 - 4270 3190 - 4100 3140 - 4040 Notes Region Southeast Interior South Southeast Southcentral Biomass Fuel Softwood Wood Pellet Wood Chips Wood Chips Green Ton - 2,000 pounds of undried biomass material. Moisture content must be specified if green tons are used as a measure of fuel energy. Units Cords 40 lbs bag Green Tons Green Tons Moisture Content % 0.25 0.45 Heating Value MMBtu per unit 14000000 352000 13200000 7920000 Year 2019 2020 2021 2022 2024 AVERAGE Operation ($) 300277 356691 431941 502213 918000 Maintenance ($) 811416 452497 616185 352265 749040 Total O&M ($) 1111693 809188 1048126 854478 1667040 Net Generation (kWh) 60078000 45644400 56412200 47843800 40012700 Capacity Factor (%) 0.278789397483016 0.211810892081524 0.261778408879979 0.222017114006757 0.185677228347626 Total O&M ($/kWh) 0.0185 0.0177 0.0186 0.0179 0.0417 0.0229 Description MW (Nameplate Capacity) Hrs/Day Days/Year Operation (assuming operating 100% of all hours) Capacity Factor 100% Production (Theoretical) Estimated Annual Production (MWh) Value 24.6 24 365 8760 0.23201460815978 215496000 49998.22