Loading...
HomeMy WebLinkAboutSWAMC - Aleutians Pribilof Islands Regional Energy Plan - Phase II Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 1 Aleutian & Pribilof Islands Regional Energy Plan Phase II – Report Update Prepared by Southwest Alaska Municipal Conference 3300 Arctic Blvd., Ste. 203 Anchorage, Alaska 99503 Information Insights 212 Front Street, Suite 100 Fairbanks, Alaska 99701 December 2015 Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 2 ACKNOWLEDGMENTS We would like to thank the following individuals and organizations for sharing their time, data and expertise. Their assistance has been invaluable. Alaska Division of Community and Regional Affairs (DCRA) Bulk Fuel Loan Program: Jane Sullivan Alaska Energy Authority (AEA): Alan Baldivieso, Katie Conway, Josh Craft, Jedidiah Drolet, Chris Gobah, Daniel Hertrich, Jessie Huff, Cady Lister, David Lockard, Kris Noonan, Douglas Ott, Devany Plentovich, Richard Stromberg, Jeff Williams Alaska Housing Finance Corporation (AHFC): Jimmy Ord, Scott Waterman Alaska Industrial Development and Export Authority (AIDEA): Mike Catsi Agdaagux Tribal Council: Della Trumble Alaska Native Tribal Health Consortium (ANTHC): Gavin Dixon, Eric Hanssen Aleut Corporation: Tara Bourdukofsky, Patricia Lekanoff-Gregory, Janet Reiser Aleutian Housing Authority: Dan Duame, Erin Wilson, Kennedy Serr, John Santos Aleutian Pribilof Islands Association: Bruce Wright Aleutian Pribilof Island Community Development Association (APICDA): Everette Anderson, Shawn Hansen, Angel Drobnica Aleutian Region School District: Joseph Beckford Aleutians East Borough: Ernest Weiss Aleutians East Borough School District: Doug Conboy Central Bering Sea Fishermen's Association (CBSFA): Jeff Kauffman Eastern Aleutian Tribes: Jennifer Harrison, Edgar Smith Frosty Fuels, Cold Bay: Michael Tickle City of Adak: Layton Lockett City of Akutan: Tuna Scanlan, Mary Tesche, Dianne Woodruff City of Atka: Julie Dirks, Jennifer Kost City of Cold Bay, G&K Utility: Gary Ferguson City of False Pass: Chris Emrich City of King Cove: Gary Hennigh, Henry Mack City of Sand Point: Andy Varner, David Osterback City of St. George: Patrick Pletnikoff City of St. Paul: Linda Snow, John Melovidov, Phyllis Swetzof, Kenneth Weaver,Mike Dahl, Bill Mathews City of Unalaska: Shirley Marquardt, Jim Fitch, Chris Hladick, Don Moore, Dan Winters Isanotski Corporation, False Pass: Sue Parker Nelson Lagoon Tribal Council: Paul Gunderson Nikokski Clinic: Doris Kompkoff Ounalashka Corporation, Unalaska: David Gregory Peter Pan Seafoods, King Cove: Glenn Guffey Petro Star, Inc.: Don Castle Pribilof School District: Connie Newman Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 3 Qagan Tayagungin Tribe of Sand Point: Jason Bjornstad, Tiffany Jackson RMA Consulting Group (for City of Akutan): Raymond Mann Shumagin Corporation, Sand Point: Glen Gardner, Charlotte Gunderson Siemens Industry, Inc.: Amber McDonough TDX Power: Agafon Krukoff, Kord Christianson, James Dunn, Ron Philemonoff Trident Seafoods: Ken McHugh UAF Interior-Aleutians Campus: Mike Hirt, Bryan Uher US Department of Energy: Givey Kochanowski USDA Rural Development: Jolene John Vitus Marine: Mark Smith Westward Seafoods / Alyeska Seafoods, Dutch Harbor: Alex Bacco, Wilt Sinclair, Chris Spengler Cover photo: Piergiuliano Chesi [CC by 3.0], via Wikimedia Commons. Inset photos (clockwise from top left): INN Electric Cooperative, National Renewable Energy Laboratory, Clickr Bee, Wolf Solar Electric Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 4 CONTENTS Acronyms and Abbreviations ...........................................................................................7 Executive Summary ...........................................................................................................9 1 | Regional Energy Planning ..........................................................................................15 Planning Area ...............................................................................................................16 Recommended Strategies ..............................................................................................17 2 | Energy Supply and Demand ......................................................................................21 Electric Power ...............................................................................................................21 Fuel Vendors and Prices ...............................................................................................29 Current and Projected Demand .....................................................................................32 Renewable Energy ........................................................................................................37 Energy Efficiency & Conservation ...............................................................................45 3 | Energy Resource & Savings Potential .......................................................................50 Energy Resource Potential ............................................................................................50 Savings Potential from Increased Diesel Efficiency .....................................................51 Savings Potential from Addressing Line Loss ..............................................................53 Savings Potential from Expanding Community PCE Use ............................................54 Savings Potential from Increased Energy Efficiency ...................................................55 4 | Stakeholder Outreach .................................................................................................58 Outreach Activities .......................................................................................................58 Next Steps .....................................................................................................................60 5 | Energy Projects & Priorities ......................................................................................62 6 | Community and Energy Profiles ...............................................................................70 A | Stakeholder Participation ....................................................................................... A-1 B | Analysis of Resource Potential ................................................................................B-1 C | Community Input and Priorities ........................................................................... C-1 D | Works Cited ............................................................................................................. D-1 E | Data Sources .............................................................................................................E-1 Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 5 INDEX OF FIGURES Figure 1: Regional Energy Planning timeline .................................................................................... 16 Figure 2: Aleutian & Pribilof Islands Energy Planning Region ........................................................... 16 Figure 3: Data availability by energy sector ..................................................................................... 21 Figure 4: 2014 Electrical sales by utility ........................................................................................... 21 Figure 5: Regional electrical generation by utility and resource, 2014 (MWh) ................................. 22 Figure 6: Diesel fuel used for electrical generation, 2014 ................................................................ 25 Figure 7: Diesel efficiency, 2014 ...................................................................................................... 25 Figure 8: Residential electrical rates by community, 2014 ............................................................... 29 Figure 9: Average diesel price paid by utilities, 2014 ....................................................................... 29 Figure 10: Retail price of #1 fuel oil ................................................................................................. 30 Figure 11: Regional electrical sales by customer type, 2014 ............................................................ 33 Figure 12: Regional trends by utility, resource, and population, 2010-2014 .................................... 34 Figure 13: Trends in average monthly use by customer type in Unalaska, St. Paul, and King Cove .. 35 Figure 14: Population trends by community, 2000-2014 ................................................................. 36 Figure 15: Aleut region residential energy use ................................................................................ 45 Figure 16: Aleut region residential energy costs compared with other re gions ............................... 46 Figure 17: Energy efficient housing stock, as of April 2014 .............................................................. 47 Figure 18: Diesel Efficiency at Different Load Sizes, FY2013 PCE Data .............................................. 52 Figure 19: Prioritization of regional energy strategies ..................................................................... 59 INDEX OF TABLES Table 1: Energy resource potential and certainty for new community-scale projects ...................... 10 Table 2: Proposed Regional Energy Roadmap ................................................................................. 11 Table 3: Administrative jurisdictions within the Aleutian & Pribilof Islands energy region .............. 17 Table 4: Factors for successful energy projects ................................................................................ 20 Table 5: Powerhouse and distribution upgrades completed or in development .............................. 26 Table 6: Heat recovery systems completed or in development ....................................................... 28 Table 7: Bulk fuel storage capacity .................................................................................................. 30 Table 8: Geothermal projects in the Aleut region ............................................................................ 39 Table 9: Hydrokinetic projects in the Aleut region .......................................................................... 40 Table 10: Hydroelectric projects in the Aleut region ........................................................................ 41 Table 11: Wind power projects in the Aleut region ......................................................................... 44 Table 12: Energy characteristics of regional housing stock .............................................................. 46 Table 13: Average EE&C savings per household in the Aleut region ................................................ 47 Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 6 Table 14: Estimated annual energy savings from residential EE&C, 2008 -Apr 2014 ......................... 48 Table 15: Participation in non-residential EE&C programs since 2008 ............................................. 49 Table 16: Energy resource potential and certainty for new community -scale projects .................... 50 Table 17: Projected annual savings from meeting diesel efficiency benchmarks ............................. 51 Table 18: Line loss by community, FY2014 ...................................................................................... 53 Table 19: Savings potential for community facilities through PCE ................................................... 54 Table 20: Estimated energy savings and potential energy savings from residential EE&C ............... 55 Table 21: Savings from energy efficient lighting upgrades in 3 Aleutian communities ..................... 56 Table 22: Savings from LED street lighting retrofits in 2 Aleutian communities ............................... 56 Table 23: Savings potential for public and commercial facilities ...................................................... 57 Table 24: Potential savings from sanitation system energy efficiency ............................................. 57 Table 25: Energy projects planned or in progress ............................................................................ 62 Table 26: Community/utility interviews, May -Aug 2015 ................................................................ A-1 Table 27: Aleutian Energy Summit attendance, March 2015 .......................................................... A-1 Table 28: Online survey respondents, Feb-April 2014..................................................................... A-1 Table 29: Wood biomass resource potential .................................................................................. B-1 Table 30: Geothermal resource potential ....................................................................................... B-2 Table 31: Hydropower resource potential ...................................................................................... B-2 Table 32: Wind energy resource potential ...................................................................................... B-3 Table 33: Coal resource potential ................................................................................................... B-4 Table 34: Oil and gas resource potential ........................................................................................ B-4 Table 35: Heat recovery resource (HR) potential ............................................................................ B-5 Table 36: Energy Efficiency savings potential ................................................................................. B-6 Table 37: Criteria used in resource potential analysis ..................................................................... B-7 Table 38: Data sources for community profiles .............................................................................. E-1 Table 39: Data sources for energy profiles ..................................................................................... E-2 Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 7 A CRONYMS AND A BBREVIATIONS AC Alternating Current ACEA Alaska Commercial Energy Audit (AEA) ACEP Alaska Center for Energy and Power (UAF) ADOLWD Alaska Department of Labor and Workforce Development AEA Alaska Energy Authority AEDG Alaska Energy Data Gateway (ISER) AEERLP Alaska Energy Efficiency Revolving Loan Fund Program (AHFC) AHA Aleutian Housing Authority AHFC Alaska Housing Finance Corporation AkAES Alaska Affordable Energy Strategy (AEA) ALARI Alaska Local and Regional Information (ADOLWD) ANCSA Alaska Native Claims Settlement Act ANTHC Alaska Native Tribal Health Consortium APIA Aleutian Pribilof Islands Association APICDA Aleutian Pribilof Island Community Development Association ARIS Alaska Retrofit Information System (AHFC) AVTEC Alaska Vocational Technology Center (ADOLWD) B/C Benefit-Cost Ratio BEES Alaska Building Energy Efficiency Standard BTU British Thermal Unit CCHRC Cold Climate Housing Research Center CNG Compressed Natural Gas DCCED Alaska Department of Commerce, Community, and Economic Development DCRA Alaska DCCED Division of Community and Regional Affairs DMVA Alaska Department of Military and Veterans Affairs DOE-IE United States Department of Energy Office of Indian Energy EE or EE&C Energy Efficiency, or Energy Efficiency and Conservation EECBG Energy Efficiency and Conservation Block Grant Program ESCO Energy Savings Company EUI Energy Use Intensity FAA Federal Aviation Administration FERC Federal Energy Regulatory Commission HDPE Hydro Dynamic Pipe Engineering (manufacturer) Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 8 ISER Institute of Social and Economic Research (UAA) Gen-set Diesel Generator Set HDD Heating Degree Days HER Home Energy Rebate program (AHFC) HUD United States Department of Housing and Urban Development kW Kilowatt kWh Kilowatt hour kV Kilovolt LED Light-Emitting Diode LMI Low and Moderate Income (HUD) LNG Liquefied Natural Gas MMBTU One million BTUs MW Megawatt MWh Megawatt hour N/A Not Applicable, or Not Available NAHASDA Native American Housing Assistance and Self Determination Act (HUD) O&M Operations and Maintenance ORPC Ocean Renewable Power Company ORC Organic Rankine Cycle PCE Power Cost Equalization P/V Photovoltaic REAP Rural Energy for America (USDA) RE Fund Renewable Energy Fund (AEA) RPSU Rural Power System Upgrade (AEA) SCADA Supervisory Control and Data Acquisition SWAMC Southwest Alaska Municipal Conference TDX Tanadgusix Corporation UAA University of Alaska Anchorage UAF University of Alaska Fairbanks ULSD Ultra Low Sulfur Diesel USDA United States Department of Agriculture VEEP Village Energy Efficiency Program (AEA) Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 9 E XECUTIVE S UMMARY The Aleutian & Pribilof Islands Regional Energy Plan is part of a statewide effort led by the Alaska Energy Authority to identify energy projects that will reduce the long-term cost of energy and dependence on fossil fuels in Alaska. The process is designed to look at the total mix of energy needs in rural Alaska, including electricity, heating and transportation, and consider all local and regional energy resources as well as efficiency and conservation. This document summarizes public input received in Phase II, especially relating to energy priorities and recommended strategies for development and cost savings. It updates information presented in the Phase I report on energy supply and demand, and it takes a new, more quantitative approach to assessing the potential for renewable and n on-renewable energy resources at the community level, which is consistent with what is being done in other regions. The goal of this phase has been to engage community and regional leaders, residents, utilities, industry representatives, and other key stakeholders in dialog about their priorities for addressing energy needs in the region and to develop a list of projects to be assessed for economic and technical feasibility in the third and final phase of the planning process. The Phase III report will identify broadly supported strategies and a list of fundable projects that can reduce energy costs in the Aleutian and Pribilof Islands region while developing local and regional energy resources. Phase I Resource Inventory and Recommendations Phase I provided an inventory of energy-related issues and resources in the region. While this inventory necessarily represented a snapshot in time, it identified both broad and community- specific recommendations that have been used to focus conversations during Phase II on the most technically feasible and economically realistic projects, given the region’s mix of resources and the current state of technology. The Phase I regional recommendations are summarized here: MAXIMIZE ENERGY EFFICIENCY WITH A FOCUS ON REDUCING THE HIGH COST OF SPACE HEATING  Improve residential energy efficiency and weatherization .  Improve energy efficiency in public and commercial buildings.  Improve energy efficiency of water and sewer systems. FOCUS ON MAINTENANCE AND EFFICIENCY OF EXISTING INFRASTRUCTURE  Upgrade diesel power system to reduce line losses, improve overall efficiency, and prepar e for integration of renewables.  Implement or expand heat recovery for community buildings where economically feasible. DEVELOPING LOCAL ENERGY GENERATION WITH A FOCUS ON PROVEN, COST-EFFECTIVE TECHNOLOGY  Pursue hydro and wind energy power where local opportunities exist. Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 10  Monitor emerging opportunities in tidal and wave power.  Evaluate availability of fish waste for community energy use. MAXIMIZE ECONOMIC IMPACT WITH A FOCUS ON COMMUNITY VIABILITY  Assess potential projects and funding options with an eye to maximizing economic impact in communities, including job creation and economic issues caused by high energy costs.  Be realistic about growth scenarios when evaluating project economics. Be prepared to make tough decisions about big projects in small communities and adding new infrastructure that will need to be maintained and upgraded over time. ADDRESS ENERGY ISSUES AND COMMON NEEDS THROUGH COLLABORATION  Identify common issues among small rural utilities that can be addressed more efficiently through information sharing and collaboration, such as training for the current and next generation of utility operators and managers, and technical assistance with PCE reporting, grant writing, project planning and development.  Convene an energy committee, working group or stakeholder forum to share information on energy projects, identify opportunities for collaboration, and help mediate community and regional differences related to energy resource development. Phase II Energy Resource Potential Analysis In Phase 2 we analyzed resources by community using standardized metrics (see Chapter 3). Potential for savings from new, community-scale projects is greatest from energy efficiency, hydro, wind, heat recovery and geothermal energy, though differences exist across communities. Table 1: Energy resource potential and certainty for new community-scale projects Adak Akutan Atka Cold Bay False Pass King Cove Nelson Lagoon Nikolski Saint George Saint Paul Sand Point Unalaska Biomass L L L L L L L L L L L L Geothermal M M M L L L L L L L L M Hydro H H H M H H L L L L L H Solar L L L L L L L L L L L L Wind H L M H L H L L H H H H Coal L L L L L L L L L L L L Oil & Gas L L L L L L L L L L L L Heat Recovery M M L M H L M L L L H H Energy Efficiency H M H H H H H H H H H H The first letter in each square represents resource potential. The subscript indicates the level of certainty in the resource potential rating. HighHL HM HH MedML MM MH LowLL LM LH Low Med High Color Key Potential 4Certainty 4 Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 11 Phase II Stakeholder Engagement and Public Input In Phase 2, we spoke with regional stakeholders, community leaders and residents about energy projects and priorities with the potential to advance the broad strategies outlined in Phase I. Outreach activities include an online survey to a broad group of stakeholders to collect input on the Phase I resource inventory and recommendations, a half-day Energy Summit in Anchorage in conjunction with SWAMC’s Annual Conference in March 2015, interviews with community leaders (in-person for Aleutian cities with offices in Anchorage), and a public website with project information and reports. During these activities, we informed the communities of the regional energy planning effort and listened for common themes that unite the region, as well as for instances where energy needs or priorities differ. Regional Energy Roadmap Based on community/utility interest and resource potential, the planning team developed a list of projects and activities with the potential to advance the regional strategies identified through the energy planning process. This list provides a potential “energy roadmap” for the region. Economic analysis in Phase III will provide additional insights on which projects have the best chance of reducing the long-term cost of energy and dependence on fossil fuels in the region. As this determination is based on currently available technology and community support (demonstrated by active leadership and/or financial support of projects) this roadmap must revisited on a regular basis to ensure emerging opportunities are not missed. Table 2: Proposed Regional Energy Roadmap Strategy Resource Actions Short Term Planning and Collaboration Energy Committee Establish a regional energy committee supported by regular meetings or teleconferences to continue the work of energy planning, support implementation of priorities, including identification of funding sources, and to share information on energy projects and needs. Bulk Fuel Cooperative Assess feasibility of forming a bulk fuel cooperative in the region among interested communities and regional organizations. Community Facility PCE Take full advantage of the PCE subsidy available for community facilities in communities that are not near their limit: Akutan, Sand Point, Unalaska and Adak. Maximize Energy Efficiency Energy Efficiency Expand participation in home energy rebate and weatherization services through education and outreach, and addressing current barriers to participation. Complete inventory and benchmarking of non-residential buildings in every community in order to establish baseline data and identify projects with the greatest savings potential. Complete recommended commercial and public facility retrofits with short to medium payback periods using loans if necessary. Investigate public ESCO model to fund retrofits in large high- energy use buildings or across multiple buildings. Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 12 Strategy Resource Actions Upgrade streetlights and public facility lighting to LEDs in all communities. Conduct energy audits of water and sewer systems and implement cost-effective retrofits. Require new installations and major upgrades to have high standard of energy efficiency. Maintain and Improve Efficiency of Electric Utilities Diesel Efficiency and Line Loss Right size the diesel generation system in Adak to address inefficiencies created by over built system. Improve diesel efficiency in other communities below AEA benchmark, including Atka, Nelson Lagoon and Nikolski. Replace distribution lines and transformers in Adak, False Pass and Nelson Lagoon to reduce line loss. Assess reasons and remedies for line loss in other communities with high (over 12%) or moderate (over 5%) line loss. Heat Recovery Expand heat recovery systems to all buildings close to power plants where economically viable. Assess feasibility of using recovered heat from power plant to heat False Pass school and Sand Point water/wastewater facility. Workforce Development Assess training needs for current and next generation of powerhouse operators, managers and utility clerks. Maintain and Improve Transportation Infrastructure to Reduce Energy Use and Costs Transportation Investigate new docks for Adak and Cold Bay and other communities that need access roads and infrastructure upgrades to reduce costs and improve safety for bulk fuel delivery. Develop Local Energy Generation Biomass Assess feasibility for Biomass projects in Nelson Lagoon, Sand Point, and Unalaska. Geothermal Continue geothermal exploration in coordination with Trident in Hot Springs Bay Valley. Hydro Assess feasibility of hydro resources in Cold Bay (Russell Creek), Unalaska, and False Pass. Complete Atka Hydro-to-Heat Project and move King Cove Waterfall Creek hydro project into development. Natural Gas Study feasibility of importing LNG by tanker to Unalaska for heat and power generation, including testing of LNG generator by the public utility. Conduct market analysis and potential impacts on bulk fuel costs in the region. Solar Assess feasibility of small-scale, community solar P/V and solar thermal projects where there is interest (Atka, St. George, St. Paul, and Unalaska). Encourage residential use, especially in off- grid areas and in facilities with high summer energy use. Space Heating Install systems using excess electricity for space heating in public buildings, like the school in Sand Point, and residential structures in communities with excess hydro and wind energy. Wind Support completion of Met tower wind studies started in Cold Bay, Nelson Lagoon, and False Pass. Initiate MET tower wind Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 13 Strategy Resource Actions studies for Adak, Atka, St. Paul, Unalaska, and King Cove (Delta Creek Valley). Replace damaged wind turbine in St. George and monitor integration into electricity grid. Collect high-quality electrical load data in order to understand power/energy uses and better model wind turbine options in the future. Medium Term Continuation of short-term activities plus… Develop Local Energy Generation Geothermal Develop Akutan geothermal resource in coordination with Trident in Hot Springs Bay Valley based on results of confirmation wells, and business and operations plans. Assess the economics of using heat pumps for space heating in communities where renewable energy generation projects are able to bring electric rates down sufficiently (below $0.23/kWh). Hydro Move hydro projects that prove feasible into design and permitting phase. Space Heating Expand use of heat pumps (air, ground, or seawater) if other renewable energy projects reduce electric rates. Add space heating components to wind or hydro project design to create secondary loads, reduce heating costs and improve project economics where excess renewable capacity exists. Wind Install wind turbines in communities where good wind resources and sufficient loads exist. If several projects are planned in the region, consider bundling purchase and installation of turbines to reduce project development costs. Natural Gas Monitor developments in Alaska natural gas pipeline planning and global LNG markets to identify any new opportunities for importing LNG to the region Long Term Continuation of short and medium-term activities plus… Develop Local Energy Generation Hydro Pursue construction of hydroelectric projects in Cold Bay, Unalaska, and False Pass if shown to be economically and technically feasible. Wind Continue to look for opportunities to develop viable wind projects within the region Geothermal Continue to look at feasibility of geothermal resources in Adak, Akutan, Atka and Unalaska. Monitor technological advances in use of low-temp geothermal for space heating and electrical generation. Hydrokinetic (In River, Tidal and Wave Power) Monitor technological advances in use of tidal and wave energy for electric generation in False Pass, Nelson Lagoon and any other communities with proven resources. Conduct site -specific feasibility studies as technologies mature and become commercially viable. Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 14 Next Steps In Phase III, rough estimates of project costs and benefits will be developed for projects included in the roadmap for which sufficient data exist. The Phase III report will also provide a draft action plan with steps local communities, utility owners and regional stakeholders can take to implement their priorities. It will be up to those in the region to decide which actions they would like to pursue based on community/utility interest and available funding or financing options. The cost-benefit information provided in Phase III will help with these decisions. State support for implementing priorities will continue through AEA’s Community Assistance program, which provides hands-on assistance in developing energy projects and addressing local issues, and through the Alaska Affordable Energy Strategy (AkAES), which could provide a future funding mechanism for energy infrastructure in areas of the state that do not have direct access to a North Slope natural gas pipeline. In regions where no regional planning group or stakeholder forum exists for working on energy issues, AEA is recommending the creation of local or regional energy committees or working groups to assist with implementation and continue the work of energy planning into the future. The agency has committed to helping support the creation of these groups as part of the final phase of the regional planning process. Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 15 1 | R EGIONAL E NERGY P LANNING The Aleutian & Pribilof Islands Regional Energy Plan is part of a statewide effort led by the Alaska Energy Authority to identify energy projects that will reduce the long-term cost of energy and dependence on fossil fuels in Alaska. The process is designed to look at the total mix of energy needs in rural Alaska, including electricity, heating and transportation, and consider all local and regional energy resources as well as efficiency and conservation. This document summarizes public input received in Phase II, especially relating to energy priorities and recommended strategies for development and cost savings. It updates information presented in the Phase I report on energy supply and demand, and it takes a new, more quantitative approach to assessing the potential for renewable and non-renewable energy resources at the community level, which is consistent with what is being done in other regions. The goal of this phase has been to engage community and regional leaders, residents, utilities, industry representatives, and other key stakeholders in dialog about their priorities for addressing energy needs in the region and to develop a list of projects to be assessed for economic and technical feasibility in the third and final phase of the planning process. The Phase III report will identify broadly supported strategies and a list of fundable projects that can reduce energy costs in the Aleut region while developing local and regional energy resources. The economic analysis will use a standard statewide methodology to provide a preliminary evaluation of project costs and benefits. The Phase III report will also provide a draft action plan with steps communities, utility owners and regional stakeholders can take to implement their priorities. Once complete, the plan is intended to serve as both a guiding document for communities and regional stakeholders and as a practical tool with information on the steps needed to move energy projects forward. Completed plans will also be used as an input to AEA’s own statewide energy planning efforts, such as the Alaska Affordable Energy Strategy (AkAES) established by the Alaska Legislature in 2014 (Senate Bill 138). Beyond the Current Planning Process Although the state’s Regional Energy Planning project will close in 2015, it is hoped that plans will continue to be updated as projects are implemented and circumstances change . A goal of the statewide project has been to develop regional capacity to continue the work of energy planning and implementing priorities. To this end, AEA is recommending the creation of local or regional energy committees or working groups. The agency has committed to helping support the creation of these groups as part of the final phase of the regional planning process. At the end of the project, energy committees or working groups will need to be self-sustaining or find support from regional partners or entities. State support for implementing priorities identified through Regional Energy Planning will continue through AEA’s Community Assistance program, which provides hands-on assistance to communities in developing projects and addressing issues, and through the Alaska Affordable Energy Strategy (AkAES), which could provide a future funding mechanism for energy Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 16 infrastructure needed to deliver affordable energy to areas of the state that do not have direct access to a North Slope natural gas pipeline (Figure 1). The AkAES is a long-term, state-directed effort to help provide affordable energy to all areas of the state if a natural gas pipeline is built from Alaska’s North Slope using revenues from a 20 percent set-aside of pipeline revenue. In 2017, AEA will make recommendations to the Legislature on infrastructure needed to deliver affordable energy to areas in the state that will not have direct access to a natural gas pipeline. To assist in the identification of infrastructure projects, AEA plans to draw on the data collected and publicly vetted through the Regional Energy Planning process. Figure 1: Regional Energy Planning timeline PLANNING AREA The planning area for this project includes the 12 communities within AEA’s Aleutian & Pribilof Islands energy region, which follows the boundaries of the Aleut Corporation established under the Alaska Native Claims Settlement Act (ANCSA) as shown in the inset map in Figure 2. Figure 2: Aleutian & Pribilof Islands Energy Planning Region Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 17 Table 3: Administrative jurisdictions within the Aleutian & Pribilof Islands energy region ANCSA Region Tribal Health Corporation Borough and Census Areas School Districts Western Alaska CDQ Program Legislative Districts For Profit: Aleut Corporation Nonprofit: Aleutian Pribilof Islands Association (except Adak, Cold Bay) Aleutian Housing Authority (except Adak, Cold Bay) Eastern Aleutian Tribes (Adak, Akutan, Cold Bay, False Pass, King Cove, Nelson Lagoon, Sand Point) Aleutians East Borough1 (Akutan, Cold Bay, False Pass, King Cove, Nelson Lagoon, Sand Point) Aleutians East Borough School District Aleutian Pribilof Island Community Development Association (Akutan, Atka, False Pass, Nelson Lagoon, Nikolski, St. George) Central Bering Sea Fisherman’s Association (St. Paul) Senate District S House District 37 Aleutian Pribilof Islands Association (Atka, Nikolski, St. George, St. Paul, Unalaska) Aleutians West Census Area (Adak, Atka, Nikolski, St. George, St. Paul, Unalaska) Aleutian Region School District (Adak, Atka, Nikolski) Unalaska City School District Pribilof School District (St. George, St. Paul) Note: 1/ Additional Census Designated Places (CDP) in the Aleutians East Borough include Belkofski Village, Pauloff Harbor, and Unga. RECOMMENDED STRATEGIES Regional Recommendations from Phase I While each community has its own set of challenges and opportunities presented by its geographic, historical, and economic condition, the Phase I report concluded with a number of broad recommendations for regional energy planning. MAXIMIZE WEATHERIZATION AND ENERGY EFFICIENCY, FOCUS ON SPACE HEATING More effort needs to go into weatherization and energy efficiency. Since heating is such a high expense for households, more impact can be made on the daily cost of living in communities if homes are properly weatherized and made more energy efficient. The household and commercial heating and electrical loads need to be reduced to what is economically feasible, and communities and regional planners have a role to help households and businesses achieve this effort. Conversion to LED lighting and energy efficient appliances will also improve efficiency and save money over time. FOCUS ON PROVEN, COST-EFFECTIVE TECHNOLOGY (ESPECIALLY HYDRO AND WIND) As government energy funds are limited, and likely to tighten in the future, communities should focus on proven technologies that will maximize return on local and government investment.  Hydropower has been shown to be effective in contributing a majority of a community's electrical load. Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 18  Wind can contribute cost effectively where there is a stable, reliable resource, though due to the variable nature of wind, current technology does not allow it to be a standalone system.  Insufficient woody biomass exists throughout the region to be a viable community-scale energy resource. Insufficient information is available to evaluate the availability of fish wastes for community energy use—all processors contacted reported utilizing the wastes economically.  Tidal and wave power are still pre-commercial technologies and not appropriate technologies for isolated communities at this point.  Geothermal is a high-risk, high-reward proposition: If a suitable reservoir can be found the resource can provide steady, consistent power, but the exploration process is very expensive and risky. FOCUS ON MAINTENANCE AND EFFICIENCY OF EXISTING INFRASTRUCTURE Prior to building new energy infrastructure, communities need to ensure that the current infrastructure operates properly through proper maintenance of the generation and distribution systems and recovering waste heat from the diesel powerhouses. MAXIMIZE ECONOMIC IMPACT, FOCUS ON COMMUNITY VIABILITY Lower energy costs will not ensure the viability of communities, but high costs can make it more difficult for a community to maintain its economic base. Funding and projects should look to maximize economic impact in the communities. This includes ensuring jobs for the communities, addressing economic issues caused by high energy prices and energy infrastructure , and lowering economic risk for homes and businesses. Communities need to be realistic about growth and economic opportunities, planning for the most likely scenario and not the stretch goal. As the populations of several communities have declined significantly in the past decade, the region and state need to make tough decisions on whether new energy projects will enhance community viability. ADDRESS ENERGY ISSUES AND COMMON NEEDS THROUGH COLLABORATION The use of a number of potential energy resources is hamstrung by disagreements among stakeholders. An independent regional stakeholder forum could increase dialog and help mediate community and regional differences. Small, independent utilities share many common needs, including training the current and next generation of operators and managers to maximize efficiency. Some common issues may be best addressed through information sharing and collaboration among small rural utility operators. Strategies for Project Development in Rural Alaska Some additional strategies for energy project development in rural Alaska have been recommended by energy planners working in other areas of the state as part of AEA’s regional energy planning effort. Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 19 LOOK AT MANY SMALL SOLUTIONS RATHER THAN FOCUS ON ONE BIG PROJECT AEA designed the Regional Energy Planning process to facilitate bottom-up, short- to medium- term energy planning driven by the needs and priorities of communities and regions. That means an emphasis on community-focused planning and solutions that can be implemented at the local level and sustained over the long term. Large, capital-intensive projects take years in planning and development and may leave small communities with infrastructure that is expensive to maintain and requires outside expertise to operate. Like other forms of community planning, the goal of energy planning should be to create sustainable, thriving communities. Rather than focus on one big energy project (or while waiting for it to pass through bureaucratic and funding hurdles), communities and regional stakeholders should consider the universe of smaller projects that can be completed more quickly and cheaply, but which cumulatively can have a big impact. FOCUS ON ENERGY EFFICIENCY IN THE SHORT TERM Given the current Alaska state budget crisis and the relatively low price of oil, there are strong reasons to focus on energy efficiency opportunities in the near term:  The outlook for new State investment in major infrastructure projects is poor, but the State is still funding popular programs to help pay for energy efficiency audits and upgrades.  Comparatively few households in the Aleutian and Pribilof Islands region have taken advantage of these programs to date and relatively few commercial and public facility energy upgrades have been performed in the region. As a result, there is still a lot of opportunity in this area.  Even without state funding, many EE&C projects pay for themselves within a few months or years. In the long-run, it costs more to wait to do efficiency upgrades than doing them now, even if a loan is needed to cover up-front costs.  A good time to invest in energy efficiency is when oil prices are down. By using some of the money not being spent on fuel (due to lower prices) on energy efficiency measures, the pain of high energy costs will be less when oil prices do go back up. TAKE ADVANTAGE OF FEDERAL PROGRAMS, ESPECIALLY FOR TRIBALLY AFFILIATED GROUPS The Department of Energy has recently increased its staffing and outreach in Alaska through the Office of Indian Energy (DOE-IE). This is a good time to take advantage of federal energy programs, especially for any entity with an Alaska Native affiliation (including federally recognized tribes, ANCSA regional and village corporations, Native nonprofits, and Public Law 93-638 compactors). Utilities may be able to partner with tribally affiliated entities to leverage these federal funds. To date, no communities in the region have participated in the DOE -IE START program, a competitive technical assistance program that provides three to five years of assistance in energy planning and project development. Every tribe is also eligible for 40 hours of technical assistance per request from DOE in a non-competitive program in which each tribe or eligible group may submit multiple requests per year. USDA Rural Development provides a source of federal funding open to all rural communities regardless of Native affiliation. Rural Energy for America (REAP) and Rural Utilities Service (RUS) are two USDA programs that can be used by Alaska utilities and small businesses to fund clean energy and energy infrastructure projects. Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 20 PAY ATTENTION TO FACTORS FOR SUCCESS Energy planning and project development are slow and iterative processes. A spirit of optimism is useful for keeping everyone focused on the goal, but it should not prevent clear-eyed vetting of proposed projects in which risks are analyzed as well as benefits. The following lessons learned about developing successful energy projects came from regional energy planners and project developers at the 2013 Alaska Rural Energy Conference (Table 4). Table 4: Factors for successful energy projects TO BE SUCCESSFUL… Energy projects must be Energy projects must have Energy planners must have  Economically viable  Technologically feasible  Supported by the local community, resource owners, utility operators, and state and local governing entities  A local champion  Long-term, reliable and sustainable fuel sources  Hope and optimism  Many conversations with stakeholders Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 21 2 | E NERGY S UPPL Y AND D EMAND Alaska’s Regional Energy Planning process is intended to look at the total mix of energy needs in rural Alaska—for electricity, heating and transportation—and to consider all local and regional energy resources including efficiency and conservation. However, data issues prevent a consistent level of detail and analysis. Good data is available on supply and demand for electrical power from the Power Cost Equalization (PCE) program, the Regulatory Commission of Alaska (RCA), and from utilities themselves. Space heating costs account for over 80 percent of home energy budgets in Alaska and around 55 percent of the energy costs in public and commercial buildings. Good data on heating fuel use, including heating efficiency and types of fuels used for heating, is increasingly available from the Alaska Housing Finance Corporation through the Alaska Retrofit Information System (ARIS). Data is better for residential buildings. While we know that transportation costs directly affect total energy and fo od costs, especially in rural areas, there is little data routinely or consistently collected on transportation costs and fuel consumption. Wholesale fuel cost and sales data is largely the proprietary data of fuel vendors. ELECTRIC POWER Electric power in the region is primarily produced by small, independent, often municipally owned, utilities. The exception is TDX power, which provides electricity to Adak and Sand Point. Six utilities generate and sell 96 percent of the power (Figure 4). Small utilities in the other five communities (False Pass, St. George, Akutan, Atka, Nelson Lagoon, and Nikolski) each produce less than 1,000 MWh per year. Each utility maintains its own distribution grid. No utilities are interconnected by transmission lines. The vast majority (94 percent) of power in the region is produced with diesel fuel, though development of renewable resources is growing and now accounts for a significant share of power in a few communities. Hydroelectricity provided 79 percent of Atka’s power and 52 percent of the power generated in King Cove in 2014. While there was no hydro power produced in Akutan last year, 25 to 44% of its electricity came from hydro in the two previous years. Electricity Good Data Heating Some Data Many Gaps Transportation Significant Data Gaps Figure 3: Data availability by energy sector Figure 4: 2014 Electrical sales by utility Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 22 Figure 5: Regional electrical generation by utility and resource, 2014 (MWh) Data source: (1) Wind energy contributed 22 percent of the municipal power in Sand Point and 13 percent in St. Paul in 2014. In total, hydroelectric projects contributed 4.0 percent of the region’s publicly available electricity last year, while another 2.1 percent came from wind energy (Figure 5). Public Electric Utilities Extensive profiles of all public electric utilities in the Aleut region are provided in the Phase I report, with updated statistical data included in the Community and Energy Profiles, starting on page 70, in the current report. A brief overview of the region’s six largest utilities, which together account for over 95 percent of electric sales, is provided below. CITY OF UNALASKA The City of Unalaska owns and operates the electrical utility in Unalaska, which has a generating capacity of 19 MW. In 2014, it produced over 48,000 MWh, accounting for 72 percent of regional electric sales. Power is sold to a largely commercial customer base, as well as to over 700 homes and 50 community facilities. While all power is diesel generated, a new 200 kW Organic Ranking Cycle generator also converts waste heat to electricity at the Dutch Harbor powerhouse. Three seafood processors in Dutch Harbor operate their own diesel powerhouses with a combined load larger than the city’s—approximately 62,000 MWh/year (2). Integrating private powerhouses into the municipal grid is one of the energy priorities the city is working on. CITY OF KING COVE The City of King Cove owns and operates the electric utility in King Cove. Averaged year round, 60 percent of the city's power is supplied by the 800 kW capacity Delta Creek hydroelectric plant, and the remainder by a diesel power plant with a capacity of 2,700 kW. In summer months, hydro production typically exceeds 90 percent and occasionally approaches 100 percent of total Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 23 generation. Conversely in winter, when the electrical consumption in King Cove is greatest, hydro generation drops below 10 percent. The switch gear to integrate the diesel and hydroelectric plants is computer controlled and fully automatic (2). ST. PAUL MUNICIPAL ELECTRIC The City of Saint Paul owns and operates the electric utility in Saint Paul. Its diesel plant has a total generating capacity of over 2.5 MW. A power purchase agreement (PPA) enables it to also buy wind energy from TDX Power, a subsidiary of Tanadgusix Corporation (TDX), the Alaska Native village corporation of St. Paul Island. (TDX Power also owns and operates utilities in Adak, Sand Point, Manley Hot Springs, and on the North Slope.) TDX Power operates three 225 kW wind turbines at its POSS Camp industrial/airport complex on St. Paul Island. With the PPA, one turbine now produces power for the city. The city’s diesel powerhouse was upgraded to integrate wind power into the municipal grid, and it purchased its first wind power from TDX in 2014. The city recently installed a flywheel for storage of excess wind energy. The turbine can be expected to deliver over 800 MWh/year based on performance at the POSS Camp. Trident Seafoods runs a separate, unconnected electrical grid on St. Paul Island with a 2.2 MW capacity. SAND POINT GENERATING / ALEUTIAN WIND ENERGY TDX Sand Point Generating, LLC has owned and operated the electric utility in Sand Point since 2000. Its diesel plant has a total generating capacity of 2.6 MW, and the generator controls are fully automatic synchronizing switch gear. TDX also operates two 500 kW wind turbines through a subsidiary, Aleutian Wind Energy, LLC. The turbines have been oversized for existing electrical load and therefore curtailed to 300 kW each. The utility is in the process of installing battery storage and additional secondary heating loads to increase utilization of the excess wind energy and allow it to operate in a “wind only” mode for up to 30 percent of the year (3). G&K INCORPORATED G&K, Inc., the electric utility in Cold Bay, was started in 1987 by owner Gary Ferguson, who was contracted by the Department of Military Affairs to supply emergency power to the U.S. Air Force Base in Cold Bay. The State also asked Ferguson to rebuild the electric utility for the community. G&K continues to supply power to the critical loads of the Air Force's Long Range Radar Site and the FAA's navigational equipment. Because of the strict operational requirements of the U.S. Air Force, G&K has never experienced an unplanned outage. The generation system includes older diesel engines that have been well maintained, but are in the second half of their useful life. The switch gear is computer controlled and is fully automatic. Cold Bay has not received funding through the Rural Power Systems Upgrade (RPSU) program (2). TDX GENERATING ADAK TDX Adak Generating (TAG) owns and operates the electrical utility in Adak, generating electricity by diesel. Given the decrease in community population since the utility infrastructure was built in the 1990s, the generation and distribution system are grossly oversized for the community load. The powerhouse has a generating capacity of 2.24 MW and manually controlled switch gear. Several generators are in need of a complete overhaul or replacement. Other serious issues include roof leaks and signs of fuel leaks at the powerhouse. The distribution system is generally in poor shape, with transformers, junction boxes, and power poles in need of repair and replacement. A health and safety inspection showed significant problems with the potential for Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 24 loss of life. The poor efficiency of the generators, high line losses, and decreasing customer base contribute to the highest residential rates in the region, both before and after PCE reimbursement. A demand charge is levied against residential customers, which can range from $0.15 to $2.00 more per kWh than the commercial rate, and is charged in addition to the power costs. This contributes to the high price volatility in Adak (2). UTILITIES PRODUCING LESS THAN 2,000 MWH The City of Akutan owns and operates the electric utility in Akutan. The diesel plant has a total generating capacity of 450 kW. The City also operates the 105 kW Town Creek hydroelectric plant. The actual production of the plant is unknown due to metering issues. The generators were recently replaced and are in good condition. The controls are manually operated synchronizing switch gear. Akutan also received RPSU funds to upgrade its distribution system. Trident Seafoods runs a separate, unconnected electrical grid with a 7 MW peak load. It is estimated to generate more than 36,000 MWh of electricity at a cost of $0.21/kWh (2). The City of Atka owns and operates the electrical utility in Atka. Electricity is generated by the 283-kW Chuniisax hydropower plant and by diesel generation. Since the hydroelectric plant came online in December 2012, it has supplied nearly 90 percent of the electricity in Atka. The diesel generation system and distribution system are in good shape and are properly sized for the community load. The switch gear is manual (2). City of False Pass owns and operates the electric utility. The city’s diesel plant has a generating capacity of 375 kW. The switchgear is manually synchronizing. New generators were installed in the recent past, however the distribution system is in poor condition, with improperly installed meters in need of replacement (2). The community is interested in renewable energy resources. Nelson Lagoon Electric Cooperative has a total generation capacity of 220 kW from diesel gen- sets. A new generator building was built in 1998 and is located near the community dock and tank farm. The powerhouse has fully automatic synchronizing switchgear. Two generators are in fair condition. A third 75-kW generator is out of service. The utility’s distribution system is in poor condition. Nelson Lagoon is in line for a Rural Power System Upgrade (RPSU) grant (2). Umnak Power Company owns and operates the electric utility in Nikolski. The diesel plant has a total generating capacity of 196 kW. Nikolski had its diesel power infrastructure rebuilt under an RPSU grant and its switch gear is fully automatic synchronizing. Generators are in fair condition, and the distribution system in good condition. A refurbished 65 kW Vestas V-15 wind turbine was integrated into the grid in 2010 with an associated heat recovery system. Currently, the system remains inoperable, because the output is more than the diesel power system can handle with the existing community load and the reaction speed of secondary loads. Nikolski applied for additional REF funds in Round 5 to address the issues, but was not funded. (2) (4). The City of Saint George owns and operates the electric utility, which produces electricity by diesel generators. The residential electric rate is the second highest in the region, due primarily to the high diesel costs on the island. The diesel powerhouse was recently rebuilt and a 95 kW wind turbine installed. The wind turbine burned out and is being replaced in fall 2015 with one of similar size. The new powerhouse includes a Web-based load control system monitored by technicians in Anchorage who are able to adjust the load required by the generators 24/7 to maximize fuel economy (5). Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 25 Diesel Efficiency Over 4.3 million gallons of diesel fuel are used annually to generate electricity in the region (Figure 6). Diesel efficiency (measured by the number of kWh generated from one gallon of diesel) currently ranges from 8.8 kWh/gallon in Nelson Lagoon to 15.7 in Unalaska (Figure 7). The red line shows AEA’s performance benchmarks of 12.5 kWh/gallon for small utilities (those generating under 2,000 MWh/year) and 14.5 kWh/gallon for larger utilities. Figure 7: Diesel efficiency, 2014 Data source: (1) While it appears that diesel efficiency in the region is in the ballpark for most utilities, there is room for improvement that would save utilities money and fuel. If utilities below the AEA benchmarks improved system efficiency enough to meet them, they would save anywhere from $0.01 to $0.17/kWh in avoided fuel costs. Collectively these utilities would save 76,000 gallons of fuel oil annually—a savings of $375,000 per year at 2014 fuel prices. See Table 17 (Chapter 3) for an estimate of potential savings from increased diesel efficiency in the region. Figure 6: Diesel fuel used for electrical generation, 2014 Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 26 Powerhouse and Distribution System Upgrades See Table 5 for a list of rural power system upgrade (RPSU) and distribution system projects that have been completed or are in progress. It also lists communities with a local priority for addressing line loss or diesel efficiency issues. AEA’s RPSU program has been limited in recent years, meaning even priority projects may not be funded in the near future. In 2014, six communities in the region had line loss above 12 percent, the threshold at which reductions in the PCE subsidy take effect. In Adak, line loss was 42 percent in FY 2014. The utility has begun to replace transformers and power lines but a critical need remains for “right-sizing” the vastly oversized powerhouse (6). According to a 2011 renewable energy reconnaissance study, this is a first step before any renewable resources can be integrated in the community (7). Other communities where line loss has been high are King Cove (17%), Akutan (15%), St. Paul (14%), and Nelson Lagoon (12%). Only Sand Point and Unalaska had a line loss of 5 percent or less in FY 2014. The recent RPSU project may have addressed many of the issues in St. George, where line loss had been the second highest in the region and the distribution system was in poor condition. See Table 18 (Chapter 3) for more on line loss and an analysis of potential fuel savings from addressing it. Table 5: Powerhouse and distribution upgrades completed or in development Community / Status Project Description Completed False Pass, King Cove, Nikolski RPSU Akutan RPSU Distribution System Upgrade St. George RPSU & Heat Recovery Scheduled or In Progress TDX Adak RPSU & Distribution System Upgrade “Right size” diesel plant and repair distribution system to address inefficiencies created by oversized system that is in poor condition, and to allow integration of one or more renewable resources. TDX Power has replaced transformers for most housing and is replacing power lines along the waterfront (fall 2015). New lines will be buried to increase reliability and protect from weather. There is still a need for a smaller power house and new, smaller generators but no funding has been allocated at this time. The project is included in AEA future project list, but funding is not guaranteed. Unalaska Local priority Integrate private powerhouses into city utility grid Priority Nelson Lagoon Transformer/Distribution System Upgrade Critical need to address high line loss through upgrade of distribution system, which is in poor condition. Transformers are beyond their useful life, and commercial and residential meters need replacement. The transmission system was measured to have a greater than 25% load imbalance across the three phases. Nelson Lagoon is in line for a RPSU grant to address these issues. False Pass Local priority Address high line losses and improve diesel efficiency. Distribution system is in poor condition with improperly installed meters in need of replacement. The electricity distribution system was found to be 10-25% out of balance in the 2012 RPSU Survey. Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 27 Community / Status Project Description St. Paul Local priority Upgrade diesel power system. Determine cause of line loss. Establish emergency generation for homes and essential services. Data sources: (2) (7), interviews with community and utility representatives (see Appendix A). Heat Recovery Heat recovery lowers community energy costs by reducing the cost of heating public buildings near the powerhouse. Even when gen-sets operate at maximum efficiency, 60 percent of the energy in diesel fuel is released as heat. Waste jacket heat can be run through a heat exchanger that transfers heat to a heat loop. This process can recover 10 to 20 percent of the energy in the fuel. The heat can be measured and, if a heat sales contract is developed, can be sold to provide another revenue source for the utility. Potential users are often schools but can be any nearby buildings. While excess or waste heat is primarily a byproduct of diesel generation, heat can be harnessed from hydro or wind projects when their capacity exceeds local electrical needs. The excess power can be dispatched on an interruptible basis to secondary heating loads, such as an electric boiler connected to a single facility’s heating system or to a district heat loop. Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 28 Table 6: Heat recovery systems completed or in development Community Buildings Heated Description Operational King Cove School, clinic, housing, and community center The powerhouse has a fairly extensive heat recovery system that supplies nearby community buildings and includes a boiler that converts excess hydroelectric power to heat. False Pass The powerhouse has a heat recovery system installed. City would like to look at feasibility of delivering waste heat to the school. Nikolski The powerhouse has a heat recovery system installed and it is operational. Sand Point The powerhouse has a limited heat recovery system St. George St. George school, city offices and the public safety building The powerhouse has a waste heat recovery system installed. The heat recovery loop was recently rebuilt as part of the RPSU project. The new system meets most of the space heating needs of the city and school (5). St. Paul Public Works office, machine shop, warehouse, fire station, gas station, bulk fuel office, fuel pump building, power plant office/storage St. Paul uses recovered heat to heat a total area of 61,000 sq. ft. The city is completing a project to upgrade and extend the heat recovery loop to work with wind-diesel system. Unalaska Power plant offices (Significant, additional industrial heating loads exist.) Unalaska uses recovered heat for hot water and space heat and to produce electricity using a 200 kW Organic Rankine Cycle (ORC) generator at the Dutch Harbor powerhouse. The system is designed for expansion to include excess heat from increased power demands when a new powerhouse is constructed. Scheduled or In Progress Sand Point School, health clinic New REF 8 project will install electric boilers at the school and clinic to use excess wind energy for space heating, and integrate building energy use data into the power plant’s SCADA system. Cold Bay Heat recovery system installed; at present it is not connected to other buildings. Cold Bay received an REF Round 6 grant to assess the feasibility of implementing heat recovery at power plant. Expected completion in 2016. No Heat Recovery Adak, Akutan, Atka, Nelson Lagoon Powerhouses do not have a heat recovery system in operation. Data sources: (2) (7) (8) Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 29 Electric Rates and Power Cost Equalization Residential electricity rates vary widely across the region from $0.30/kWh in King Cove to $1.44/kWh in Adak. The state’s PCE subsidy brings down the effective rate for the first 500 kWh of monthly residential use (Figure 8). For comparison, rates were $0.15/kWh in Anchorage in March 2015. Figure 8: Residential electrical rates by community, 2014 Data source: (1) FUEL VENDORS AND PRICES Fuel Prices Fuel prices are a large component of electricity rates, especially in communities producing all or most of their power through diesel generation. Fuel prices are set on global markets, but the delivered price can vary widely due to transportation costs. Factors affecting fuel price include distance from the distributor’s linehaul routes, volume purchased, safety and ease of offloading at docks, contract terms, and the competitiveness of the market. (Some communities are served by only one vendor.) The retail price of fuel oil for home heating is usually higher than the prices paid by utilities. Figure 10 shows that prices in four Figure 9: Average diesel price paid by utilities, 2014 Data source: (1) Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 30 communities in the region are an average of $0.60 to $1.78 higher than Anchorage prices in most years. Fuel Vendors Crowley, Delta Western, Vitus Marine, Trident Seafoods and Adak Petroleum are the primary fuel vendors in the region. Most communities use #2 diesel or #2 Ultra Low Sulfur Diesel (ULSD) for both electrical generation and space heating. A few communities have only one fuel vendor who delivers. Bulk Fuel Storage Most communities in the region have adequate bulk fuel storage. Bulk fuel upgrade (BFU) projects have been completed in Akutan, Atka, False Pass, King Cove, Nelson Lagoon, and Nikolski. Future projects are slated (but not scheduled or funded) for Cold Bay, St. Paul and Sand Point. Table 7 lists the known tank capacity for diesel fuels. Storage capacity for other transportation fuels is not included. Table 7: Bulk fuel storage capacity Fuel Community Past Vendors Capacity (Gals.) Owner / Uses Jet A (High Sulfur #1) Cold Bay Crowley, Delta Western 300,000 Frosty Fuels: Jet fuel and heating oil #1 Diesel Atka 30,000 Residential & community heating False Pass 27,000 Peter Pan: Heating oil. Nelson Lagoon Crowley 81,000 Residential heating #2 Diesel (includes ULSD) Adak Adak Petroleum, a subsidiary of the Aleut Corporation 20,000,000 City Power Plant, community buildings, residential heating, fishing Akutan 80,000 City of Akutan 5,000,000 Trident Seafoods facilities, fishing boats Atka 60,000 Heating, fishing boats 40,000 Electrical Generation Cold Bay Crowley, Delta Western 13,450 G&K Power Plant (Typically ULSD #2) 110,000 Frost Fuels False Pass 65,000 City (owner). Power Generation 300,000 Fishing, etc. Figure 10: Retail price of #1 fuel oil Note: Prior to 2011, the month in which fuel price data was collected varies by community. When data from the same month was not available, the closest month (within 3 months) was used. Data source: (13). $0.00 $1.00 $2.00 $3.00 $4.00 $5.00 $6.00 $7.00 2005 2007 2009 2011 2013 2015Per GallonKing Cove Sand Point St. Paul Unalaska Anchorage Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 31 Fuel Community Past Vendors Capacity (Gals.) Owner / Uses #2 Diesel (includes ULSD) King Cove 159,500 City of King Cove: power plant, community buildings, some residential heating 1,000,000 Peter Pan Seafoods: Peter Pan facilities, fishing boats, residential heating, transportation Nelson Lagoon Crowley 54,000 Power generation Sand Point Trident Seafoods 41,000 TDX Power Plant 800,000 Trident Seafoods facilities, fishing boats, residential heating, transportation St. George 1,066,200 Saint George Delta Fuel. Electrical generation and residential heating. St. Paul 1,847,500 City of Saint Paul 1,500,000 TDX Corp. 300,000 Coast Guard 12,000 Trident Seafoods Multiple fuel types Unalaska Multiple vendors from Cook Inlet and West Coast refineries 16,000,000 Delta Western Fuels 4,000,000 Petro Star (Plus multiple smaller tanks for utility, processors, etc.) Note: Does not include storage for other transportation fuels (AV gas, unleaded gasoline, etc.). Data source: (2) Natural Gas Cleaner burning and lower cost than gasoline or diesel per unit of energy, natural gas could be another energy choice for the region if a reliable, affordable supply can be imported in the forms of LNG, CNG and propane. Liquefied Natural Gas (LNG) is created when natural gas is pressurized and cooled to less than -260 °F allowing it to be easily stored and transported worldwide by tanker. Compressed Natural Gas (CNG) is a transportation fuel that provides a cleaner burning alternative to gasoline. Propane is primarily a space heating and cooking fuel. Though tied to global oil markets, prices for these natural gas products have generally been falling as production has increased (9). The City of Unalaska continues to look at the option of importing LNG to produce electricity. According to the Unalaska’s Director of Public Utilities, preliminary calculations justify further testing in the form of running an LNG generator for a period of time and comparing performance and cost to diesel generators. The city is presently considering moving to this next step (10). If tests are favorable, a detailed feasibility study is still needed to look at costs for storage, regasification, distribution, and the conversion of energy infrastructure for both powe r generation and heating. The economics of a project may hinge on the amount of diesel that can be displaced. LNG can be delivered in large bulk tankers, which hold significantly more fuel than Unalaska's yearly consumption, or in smaller individual tanks (10,000 gallons or less). Regional considerations include whether an Unalaska LNG import project would make LNG more available to other communities or industrial users on the Aleutian chain, as well as the potential impact on bulk fuel prices in the region. If natural gas displaces up to 10 million gallons of diesel fuel used annually in Unalaska, regional prices could rise for other fuel types as the total volume brought to the regional hub is slashed (2). Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 32 CURRENT AND PROJECTED DEMAND Demand for Electricity Nearly 69,000 MWh of electricity are produced and sold annually by public utilities in the Aleut region. Regionwide, 75 percent of this is used by commercial and government customers and 13 percent by residential customers. Public buildings and utility use account for the remaining 12 percent. However, there is considerable variation by utility in where electricity is used, with residential customers accounting for a high of 38 percent of use in Sand Point and public facilities reaching 25 percent of sales in King Cove. The largest commercial use is in Unalaska, accounting for 83 percent of all sales (Figure 11). Mostly missing from these charts is electrical use by the region’s fish processors who maintain their own generators. While the primary energy consumer in the region—possibly consuming more than all residential and commercial consumers combined —there is little data available on the fuel or electrical use of the region's seafood plants (2). Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 33 Figure 11: Regional electrical sales by customer type, 2014 Data: PCE Annual Report (1) Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 34 Recent Trends in Electrical Generation Regionwide, total generation has increased 31 percent since 2010, with increases coming from diesel (29%), hydro (32%), and wind (903%) (Figure 12, right). Growth in total generation has primarily been at the region’s largest (Unalaska 54%) and a few of its smallest utilities. Generation and sales at other utilities have declined, including St. Paul (14%), King Cove (10%), and Sand Point (9%), while others have remained relatively flat (Figure 12 left), following trends in population (Figure 14). The region’s total population grew 1.4% from 2010 to 2014. Figure 12: Regional trends by utility, resource, and population, 2010-2014 Data sources: (1) (11) Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 35 Recent Trends in Average Customer Use Average monthly electrical use fell slightly over the past 5 years for residential and community facility customers at the region’s three largest utilities, which may reflect the impact of higher prices and the push for increased energy efficiency and conservation. These declines have been more than offset by a 25 percent increase in average use among commercial and government customers, resulting in an overall growth of 12 percent in kWh sold per customer (Figure 13). Figure 13: Trends in average monthly use by customer type in Unalaska, St. Paul, and King Cove Data source: (1) Population Trends and Projections Since 2000, population in the Aleutian and Pribilof Islands has grown nearly 8 percent regionwide, an average of about 0.5 percent per year (Figure 14), though that growth has almost exclusively occurred in communities with populations over 500. Unalaska and Akutan each added 300 to 400 residents since 2000, while King Cove added over 100. In Akutan the increase was in group housing, not in the village, which has seen its population decline in the last 5 years from 90 to 70. The sharpest declines have been in the smallest communities, which have lost around half their population since 2000. Alaska’s state demographers predict the region’s population will remain relatively flat at around 9,000 people over the next several decades, possibly declining by a few hundred individuals regionwide (12). Given the importance of the fishing industry to the region’s economy, any population projections are highly dependent on the health and sustainability of the fish stocks. The addition of a single, new fish processing plant in a community would increase both its population and power needs. Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 36 Figure 14: Population trends by community, 2000-2014 Data sources: (13) (11) Load Forecasts Looking at trends in electrical sales, population, and the overall economic outlook in the state, it is likely that electrical loads will remain flat or grow slowly unless large industrial users enter the market or expand operations. Royal Dutch Shell was using Unalaska as a base for offshore oil and gas exploration in the Beaufort and Chukchi Seas. With Shell’s decision in 2015 to end offshore oil exploration in Alaska for the foreseeable future, increases in the electric and heating loads in Unalaska, the region’s largest market, are not expected. However, future changes to drilling operations would likely have an impact on Unalaska’s heating and electric load. Increased use of electricity for space heating in communities with excess renewable energy will create secondary loads for electric utilities that pursue “wind to heat” or “hydro to heat” projects. The increased use of heat pumps could also increase loads in communities if they become more 2000 2014 Change Avg. Annual Community Census Est.Since 2000 Growth Over 500 Unalaska*4,283 4,689 9.5%0.6% Akutan*713 1,052 47.5%3.2% Sand Point*952 946 -0.6%0.0% King Cove*792 905 14.3%1.0% 101 to 500 St. Paul 532 436 -18.0%-1.2% Adak*316 247 -21.8%-1.5% 51 to 100 St. George 152 92 -39.5%-2.6% Cold Bay 88 89 1.1%0.1% Atka 92 70 -23.9%-1.6% 50 or Under Nelson Lagoon 83 44 -47.0%-3.1% False Pass 64 34 -46.9%-3.1% Nikolski 39 15 -61.5%-4.1% * Includes population in group quarters such as barracks and dorms Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 37 economic due to lower electric rates or improvements in technology. New loads may be offset to some extent by continued investment in energy efficiency, where there is still considerable savings opportunity. Transportation and Heating Fuel No public data is available on the volumes of fuels used for transportation and space heating. RENEWABLE ENERGY Renewable resources currently helping to meet energy needs in the region include hydropower and wind energy for electric production, with an increasing use of excess capacity to address space heating needs. Seafood processors in the region are using oil from fish waste as a biodiesel fuel for their own heating and power needs or selling it to market (2). Projects using other renewable resources are either still in development, or there are insufficient resources within the region given the current state of technology. The Phase I report provides an in-depth inventory of all renewable resources on a community by community basis (2). A further analysis of resource potential is included in the current report in Chapter 3. The section below provides a summary of only those renewable energy projects that are operational or are in development in the Aleut region, though in some cases it mentions projects that were previously considered but are not being pursued at the present time . Community energy priorities that are not yet identified with a project are included in Chapter 5. Biomass Biomass is organic material such as wood, municipal waste or fish byproducts used to produce energy. Most biomass is burned for heat, but some technologies convert it into electricity. WOODY BIOMASS Insufficient woody biomass exists throughout the region to be a viable energy source , although local areas of driftwood can be useful for non-community use. Only one community (Nelson Lagoon) reported interest during stakeholder discussions in a pre-feasibility assessment of wood biomass as a community-scale resource. SOLID WASTE Unalaska is interested in assessing the feasibility of using solid waste incineration for energy production. FISH OIL Seafood processors report using oil from fish waste economically either in boilers or power plant generators, or selling it on the international market. It is not known whether there are sources of fish oil from the region’s processing plants that could be available for community energy use (2). In Akutan, Trident Seafoods uses its fish oil in boilers or sells it commercially, depending on the international demand for fish oil. In Dutch Harbor, Alyeska Seafoods processes fish oil to be blended with diesel—up to 800,000 gallons in a peak year. Westward Seafoods uses fish oil in its boilers to produce steam. It has used fish oil in gen-sets since 2002 in a 50/50 ratio with diesel. Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 38 Approximately 400,000 gallons of fish oil are burned annually compared with total diesel consumption in a recent year of approximately 1.7 million gallons, two-thirds for power production (2). Geothermal Geothermal energy is a high-risk, high-reward proposition: If a suitable reservoir can be found the resource can provide steady, consistent power, but the exploration process is very expensive and risky. While several geothermal studies have been conducted in the region, no projects have yet been developed, though the Hot Springs Bay Valley project in Akutan is in final design. Several other communities are known to have geothermal potential (Adak, Atka and Unalaska). While power generation has often been the goal of geothermal development, there are cases where using the resource to heat large building loads may be a simpler, more cost effective start to developing promising resources. Given the high risk/high reward nature of geothermal development (and a 90 percent average failure rate, industry-wide, of projects at the feasibility stage), rigorous feasibility work is needed to assess economic viability of these resources (2). AKUTAN The Hot Springs Bay Valley geothermal resource on Akutan could potentially supply all heat and electricity needs for the island, including the village, the new harbor, and Trident Seafoods. However, the project is estimated to cost $65 million and given the high risk nature of geothermal drilling, the Phase I report concluded that geothermal development should be a last priority for renewable resource development. Trident Seafoods would be the primary beneficiary of any development, and the power needs of the small community can be met by lower risk and lower cost options. While there is sufficient heat in the valley to power a geothermal plant, it is unknown if a site with sufficient permeability, porosity and fluid volume flow rate can be discovered to build an economically viable project (2). Preliminary technical feasibility and an economic assessment were completed in 2009-2010. Exploratory drilling of two test wells was completed in August 2010. The project is now in final design and permitting. As part of this phase, a Power Sales Agreement and potentially a direct investment partnership with Trident Seafood Corporation will be enacted, and the economic and financial analysis will be updated to include the most current information and will be developed into a final business and operational plan (7). In January 2015, project engineers recommended the drilling of a 1,500 foot confirmation well to more precisely locate and size the resource for a potential 2-3 megawatt power plant. Drilling permits have been issued, and the drilling is scheduled for summer 2016 (14). UNALASKA Significant exploration work has been done at the Makushin geothermal site over the past 35 years, a combination of state, regional, and private interests. The prospect remains undeveloped. A recent study indicates geothermal resources present greater financial risk than the City of Unalaska can take on and the landowner has presented unreasonable demands. This project has been removed from the city’s priority list. Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 39 Table 8: Geothermal projects in the Aleut region Project Lead Entity Resource Next Steps Cost Funding Feasibility & Design Akutan Geothermal Development Final Design City Utility Geothermally active area on flank of Akutan volcano with many hot springs and fumaroles. The valley is about 4 mi. from the city, but not easily accessible. Drilling of confirmation well in Hot Springs Bay Valley and completion of final design and permitting, power sales agreement with Trident Seafood, business and operations plan. Total project cost $65 million (estimated) AEA REF 2/3/4 ($5.82 million total), US DOE ($931,000), Local Match Previously Considered Makushin Site (Unalaska) City This project has been removed from the city’s priority list Hydrokinetic (Tidal and Wave Power) There are no operational hydrokinetic projects in the region. Tidal and wave power are still emerging technologies that may be able to provide significan t renewable energy in the future. Tidal power uses turbines, similar in principle to wind turbines, to convert tidal currents into electricity. Different designs are being tested across the globe, but no commercially available devices have been developed. More designs are being tested for wave power, which uses a number of different mechanical means of converting ocean waves into electricity. The benefit of hydrokinetic power is that it would represent a predictable, if inconsistent, energy source. Significant issues still exist before it can be proven technically and economically effective in a remote location without significant subsidy and risk. The ocean environment is particularly challenging—the forces acting on the devices are great and the corrosive effects of sea water are well known. In addition, there are logistical challenges in deploying devices, and the lifespan and economics of the devices are still not known (2). TIDAL POWER MONITORING AND DEMONSTRATION While several communities in the region (False Pass, Nelson Lagoon) have outstanding tidal basin flows, there still remains to be a successful and continuous demonstration of technology to harness the tidal flows for electric power generation. If a robust and simple demonstration project can be made sustainable by the local utility for several seasons, demonstrated outside the region first, then the possibility for larger investment can occur (2). The City of False Pass has done reconnaissance and feasibility work on its tidal resource, but its current focus has shifted to conventional hydroelectric feasibility. During the summer of 2012, Ocean Renewable Power Company (ORPC), a company developing a tidal energy turbine, performed a site assessment in Isanotski Strait through a DOE Tribal Energy grant. The completed reconnaissance showed that one site had the potential to produce approximately 600,000 kWh per year using ORPC’s prototype 150 kW TidGenTM power system. Although the study showed that the community's total energy could be nearly covered with one tidal power system, the tides, while highly predictable, are not constant. Without cost effective storage, diesel would have to supply power during times the tides are not sufficiently energetic, and the excess produced at peaks would likely need to be dumped as a heat load. Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 40 Table 9: Hydrokinetic projects in the Aleut region Project Lead Entity Resource Next Steps Cost Funding Previously Considered False Pass Hydrokinetic Feasibility and Conceptual Design City Isanotski Straight Measure velocities and turbulence at 3-5 sites in Isanotski Straight, do circulation modeling, environmental assessment, conceptual design, economic analysis, and outreach. $566,466 REF 7. (Total project estimated at $5 million.) AEA REF 7, APICDA, NREL (DOE funded reconnaissance study) Hydroelectric Power Hydropower converts the potential energy of water into electricity by sending it through a turbine connected to an electrical generator. Hydro power projects can either involve a reservoir with a dam or be run-of-river. A dam is generally more expensive and causes greater environmental impact, but it has the benefit of storing water that can be dispatched as power is needed. Without the ability to store water, a run-of-river project is a more seasonal resource. It involves piping the water through a penstock to the powerhouse (2). There are three operational hydroelectric projects in the region (Table 10). While supplying only 4 percent of the region’s total electric power, they typically contribute a majority of their community’s annual electric loads. Hydroelectricity provided 79 percent of Atka’s power and 52 percent of the power generated in King Cove in 2014. While there was no hydro power reported in Akutan last year, 25 to 44% of its electricity came from hydro in the two previous years. KING COVE The 375 kW Waterfall Creek Hydroelectric Project is located approximately 5 miles north of the City of King Cove and is within one half mile of the existing Delta Creek hydroelectric plant. Because the two sites are relatively close to one another, the powerhouse for the Waterfall Creek project will co-locate in an expansion of the existing Delta Creek powerhouse and use the existing transmission line to King Cove. The project will consist of a small diversion dam and intake, a 4,500 HDPE penstock, a 16x40 powerhouse expansion, a Pelton Impulse Turbine and 5,000 ft. of access roads. Expected completion of final design and permitting was November 2014. $3.9 million in construction funds were authorized in REF Round 6 (8). AKUTAN The hydroelectric plant at Town Creek was originally built in 1994. The 1.7 acre reservoir has a 20 acre watershed. A 3,300 foot pipe extends 765 vertical feet from the reservoir to the power house. A 150 kW Pelton turbine was originally installed. In 2011, $1.1 million from AEA's Renewable Energy Fund was used to reconstruct the infrastructure . The hydro system has been operating routinely since 2013. Overall the project's reported capacity factor has been 34%, which is likely higher than actual. Since the renovation and reintegration of the Town Creek hydroelectric plant in 2012 the contribution of hydro to the total power supply is unknown due to metering issues. Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 41 ATKA Since the Chuniisax Creek plant has come online in December 2012, hydroelectricity has supplied up to 90 percent of Atka’s power. The hydroelectric plant consists of a 283 kW, cross- flow turbine operating on 116 feet of head. A 13 foot high concrete dam feeds a 1,060 foot penstock that delivers an average of 36 cubic feet per second (cfs) of water to the turbine. 39 acre-feet of storage behind the dam can help extend the yearly production. The project has the potential of generating 1,760,000 kWh/year, well above the community’s needs. A project to dispatch excess hydro power to secondary heat loads has not yet started, pending upgrades at the powerhouse. The city has received $135,289 in REF Round 7 funds, following a previous REF Round 3 grant for a total of $207,874. Table 10: Hydroelectric projects in the Aleut region Operational Under Construction Feasibility & Design Previously Considered City of King Cove Delta Creek 800 kW Run of River completed in 1995. Provides 50-60% of local electricity. Waterfall Creek 375 kW Run of River in final design and permitting. Will use expanded Delta Creek hydro powerhouse. (REF Rounds 5, 6 funding) Ram Creek (Deemed infeasible) City of Atka Chuniisax Creek Hydroelectric 283 kW Began supplying power in December 2012. Atka Dispatchable Heat Design & Construction Hydro-to-Heat project on hold pending powerhouse upgrades (REF Rounds 3/7 funding) City of Akutan Town Creek 105 kW Repair and upgrades completed in 2014 Loud Creek Feasibility study complete. No further grant funds awarded. City funded continuation of flow measurements. Solar Solar has been considered to be economically marginal in Alaska compared with other renewable technologies. However, less expensive solar panels, federal and state tax c redits, and net metering programs where available, have combined to shorten the payback period for solar projects, especially in communities where electric rates are highest, customers pay non-PCE rates or utility lines do not reach. Solar P/V technology is also relatively simple to install and maintain compared with other renewable technologies. With an average insolation of less than 2kWh/m2/day, the Aleut region has less of a solar resource than some Interior regions. However, several communities are interested in looking into potential solar projects (see Chapter 5). Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 42 Wind Wind energy is generating an increasing share of municipal electric power in Sand Point and St. Paul, where it provided 22 percent and 13 percent of public generation respectively in FY 2014. Both utilities are in the process of expanding their capacity to utilize excess wind power by installing storage and additional secondary heat loads. A malfunctioning wind turbine is scheduled to be replaced in St. George in fall 2015. Nikolski installed a refurbished wind turbine in 2010, but it is not operational due to difficulties integrating into the community’s small grid and the slow reaction speed of secondary loads (7). Most other communities in the region have begun or completed wind feasibility studies. See Table 11 for a list of operational projects and those in development or previously considered. ASSESSING WIND FEASIBILITY: SITING AND SIZING ISSUES Because the Aleutian & Pribilof Islands have characteristically strong but gusty winds, and have significant geographic volcanic relief (steep hills, narrow valleys), locating proper sites for utility scale wind is still an emerging practice. Turbulence can cause damage to the turbine. Buildings and topography are the main causes of turbulence in the region. Because of the wind strength and turbulence in the region, AEA does not recommend turbines smaller than 95 kW in capacity. Meteorological (met) towers are used to monitor the wind in an area prior to erecting a wind turbine in order to find an area that will maximize power production. Since the wind varies over time, the resource should be monitored for a minimum of one year. There are several communities in the region where comprehensive met tower monitoring has not been completed despite good potential for utility scale turbines (Adak and Atka) (2). INTEGRATING WIND ENERGY INTO THE POWER GRID Because of its variable and unpredictable nature, the total capacity of a wind turbine must be limited compared to the overall size of the grid, or it can cause frequency and voltage issues. Wind gusts can cause power surges that damage devices, and lulls can cause brownouts or blackouts if the diesel generators are unable to respond quickly enough. In order to safely integrate wind power, AEA does not recommend more than 30 to 50 percent wind penetration (the proportion of electrical power provided by wind). Even at these levels specialized controls are needed ensure grid stability. If a community does not have a sufficient electrical load to use all the wind power produced at peak output, secondary or “dump” loads are required that can operate on a dispatchable, or on- demand, basis. A dump load can be a large resistive bank that vents to the atmosphere (in which case the wind energy is lost) or a secondary heating load, such as an electric boiler, to heat nearby buildings. If a heat sales agreement can be made between the utility and the end user, secondary loads can be another revenue source for the utility. New systems may allow smaller buildings and residences to distribute the heat load throughout a community by directing excess power to buildings via central control and Ethernet connections (2). Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 43 PROJECT UPDATES The following project updates are primarily based on AEA’s January 2015 Renewable Energy Fund Status Report (7). Cold Bay. A meteorological tower was installed on August 9, 2012. On March 26, 2013, AEA was informed by Marsh Creek that data was finally collected from the met tower but was not retrievable from the data card. The data card and logger are being sent to NRG in the event they can retrieve the data. A new logger has been installed. AEA requires a minimum 12 months of data to demonstrate the wind regimen. Data collection is ongoing but the project will be delayed due to the loss of data. False Pass received an REF Round 4 grant from AEA to do a wind feasibility assessment. Data collected from 2004 to 2006 was used to draft a Conceptual Design Report (CDR). Based on the amount of turbulence found and the small size of the community grid, AEA recommended that the utility not proceed to the next phase of project development at this time. King Cove. A 2013 feasibility report, based on 2005-2006 data, showed a Class 7 wind resource in the Delta Creek area. Turbulence levels are too extreme for current technology; AEA does not recommend further development. Nelson Lagoon received an REF Round 1 grant from AEA to look at wind potential. AEA adjusted the scope and budget to add an avian study to address the avian issues in the community. A modified 40’ free standing monopole tower was installed in May 2012 and data collection and the avian study are ongoing. A draft Conceptual Design Report (CDR) will close out the grant. Nikolski. TDX Power installed a 65 kW V-15 wind turbine on behalf of the utility in 2007, using an USDA Rural Utilities Service grant and financial support from the APICDA. Due to control panel incompatibility, commissioning was not completed until 2010, with an AEA REF Round 1 grant. Currently the turbine is wired to the power plant but not successfully integrated into the grid. The energy produced by the turbine is more than the power plant can handle along with the existing community load and reaction speed of secondary loads. Nikolski requested an additional $331,000 from Round 5 to integrate the turbine into the power system and develop a heat recovery system and provide for electric boilers in the lodge and school to use excess wind energy. The project was approved for funding as a smaller amount, but funding was not allocated. Sand Point received full funding in REF Round 8 for a Wind-to-Heat project to install electric boiler in the school to heat the swimming pool (per original design of its wind project) to increase wind utilization and improve performance. St. George worked closely with AEA’s Wind and RPSU Programs to install a wind-diesel system that integrated a 95 kW turbine purchased with an REF Round 1 grant from AEA into the new power plant. The turbine was damaged and is scheduled to be replaced in October 2015. St. Paul. The St. Paul wind diesel project (REF Round 3) connected one or two of TDX’s turbines on St. Paul into the City of St. Paul’s grid and made necessary upgrades to the city’s facilities and transmission system. Because the project was completed under budget and the size of the secondary loads and diesel generators was limiting the amount of wind power produced, Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 44 the grant was extended to include installation of a flywheel (for energy storage), met tower, and additional secondary loads. The city’s newest generator, along with the additional secondary loads, should eliminate the bottle neck. The flywheel has been installed and is now being tested. Table 11: Wind power projects in the Aleut region Project Lead Entity Scope Cost Funding Operational Sand Point Wind Construction Aleutian Wind Energy (IPP) Installed 2 Vestas V-39 wind turbines with 395 kW resistive, air cooled load bank, new 455 kW CAT3456 genset, at powerhouse and dump loads in community buildings. $1.08 million (not including cost to complete remote boiler system) AEA REF 2, US DOE, Local Match St. Paul Wind Diesel Construction TDX Corp. (IPP) Integrated power from one of three TDX wind turbines to the City grid with necessary upgrades to the powerhouse and transmission system. $2.1 million (plus $1.5 million for turbines) AEA REF 3, US DOE, Local Match In Development Atka Wind Energy Feasibility Installed several met towers in 2015. Complete one year of data collection and draft feasibility study. APICDA support Cold Bay Wind Energy Feasibility G&K Electric Utility (IPP) Complete feasibility assessment with full year of data from met tower installed in 2012. $104,075 AEA REF 4, Local Match King Cove Wind Energy Feasibility Identify new test sites in Delta Creek Valley; monitor technology to find best system for strong winds; complete study. Nelson Lagoon Wind Energy Feasibility & Conceptual Design Utility Cooperative Complete avian study and draft CDR based on data collected from modified 40’ monopole tower. $104,075 AEA REF 4, Local Match Sand Point Energy Storage Design & Construction TDX Sand Point Generating Install an inverter and battery bank to store excess wind energy. $1,397,403 AEA REF 7, Local Match St. George Wind Farm Construction / Wind Turbine Replacement City Replace 95 kW burned-out wind turbine with one of similar size and type. Ensure proper integration with new power plant. AEA REF 1 St. Paul Flywheel (add-on to Wind-Diesel Construction project) TDX Corp. (IPP) Complete testing of flywheel for storage of excess wind energy. Install met tower and additional secondary loads. $2.1 million total wind-diesel project (plus $1.5 million for turbines) AEA REF 3, US DOE, Local Match Previously Considered Adak Diesel Hybrid Reconnaissance TDX Adak Some potential for wind energy based on 2011 reconnaissance work but need to gather load data and address issues of oversized power $82,125 AEA REF 2, Local Match Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 45 plant and distribution system before integrating renewables. False Pass Wind Energy Feasibility & Conceptual Design City Utility Based on wind resource study and draft CDR, AEA concluded that False Pass’ electrical system is not currently capable of using wind power. Total $126,125 AEA REF 4 & 7, Local Match Nikolski Wind-Diesel System Redesign, Construction and Commissioning Native Village Complete integration and commissioning of 65 kW Vestas V15 wind turbine, develop a heat recovery system at powerhouse and provide electric boilers in lodge and school to use excess wind. $331,240 (estimated cost in 2012) Previous funding: USDA RUS, APICDA, AEA REF 1 ENERGY EFFICIENCY & CONSERVATION Energy Characteristics of Regional Housing Stock The 2014 Alaska Housing Assessment by the Cold Climate Housing Research Center (15) profiled the residential energy use and cost in the Aleut region:  Energy Use: The average home in the region is 1,230 square feet and uses 115,000 BTUs of energy per square foot annually (16 percent less than the state average). Almost two-thirds (65 percent) is used for space heating, another 18 percent for hot water, and 17 percent for electricity.  Energy Efficiency: The average home energy rating in the region is 2-star plus, based on data from over 200 homes. Not surprisingly, newer homes have better energy performance. On average, homes built in the 1940s are currently rated at 1-star plus, compared to an average rating of 4-star-plus for homes built after 2000.  Housing Quality: Within current housing stock, newer homes are tighter. On average, homes built in the last decade exceed the 2012 BEES standard of 4 air -changes per hour at 50 Pascals. In contrast, homes built in the 1950s are 3.5 times leakier than those built since 2000. About 37 percent of occupied housing are relatively air-tight, but lack a continuous ventilation system, putting these home at higher risk for indoor moisture- and air-quality issues.  Energy Cost and Affordability: The average annual energy cost for homes in the Aleut region is $6,710, which constitutes approximately one percent of median area income in the region. Approximately 25 percent of households spend 30 percent or more of their income on housing costs, including rent, water and sewer, and energy costs.  Regional Comparison: Energy costs per square foot are in the middle when compared with homes in other regions of the state (Figure 16). The average annual home energy cost in the region is approximately 2.4 times more than the cost in Anchorage, and 3.2 times more than the national average. Figure 15: Aleut region residential energy use Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 46 Table 12: Energy characteristics of regional housing stock Avg. Energy Rating Avg. House Size Avg. Annual Energy Use Avg. Annual Energy Cost Avg. Energy Use Intensity (EUI) Avg. Energy Cost Index (ECI) Avg. Home Heating Index 2-star Plus 1,230 square feet 156 MMBTU $6,710 (Jan 2013 $) 115 kBTU per square foot $5.04 per square foot 7.8 Data source: (15) Figure 16: Aleut region residential energy costs compared with other regions Source: (15) Residential EE&C Program Participation One in six (18%) occupied homes in the region have completed energy upgrades through the Home Energy Rebate program, a low-income weatherization program, or is a newer BEES- certified home (Figure 17). (This does not include homes weatherized with private funds.) Participation in AHFC’s Home Energy Rebate program is open to homeowners for their primary residence; there is no upper income limit. The HER program requires homeowners to pay for recommended upgrades up front and reimburses them for direct labor and materials up to a certain amount once work is performed and a “post” audit is completed. Residents in Adak, Sand Point, and Unalaska have participated in the program (though none in Adak completed the work in the time provided in order to receive a rebate.) In the Aleut region to date 39 percent of homeowners receiving HER audits have completed upgrades and received rebates. AHFC’s weatherization service provider in the region is the Aleutian Housing Authority (AHA), which has completed weatherization projects in all communities it serves. The program spends up to $30,000 per home in remote rural communities, including transportation, logistics, overhead and health and safety measures (16). There is no cost to the resident or community for participation in the program. A total of 245 homes have been weatherized since the program started in 2008. Regional Housing Authorities may finance additional weatherization work with federal funding, including Native American Housing Assistance and Self Determination Act (NAHASDA) grants through the U.S. Department of Housing and Urban Development. Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 47 Figure 17: Energy efficient housing stock, as of April 2014 Data sources: (17) (15) While no residents in the region have yet received AHFC’s New Home Rebate (for buying or purchasing a 5 Star Plus or 6 Star home), 28 homes have been certified as meeting Alaska Building Energy Efficiency Standard (BEES), which is required for AHFC financing. Information on program participation in each community is included in Table 14. Residential EE&C Savings Energy efficiency and weatherization measures completed since 2008 have been saving program participants in the region 31 to 35 percent per year on their home energy consumption, according to AHFC data, which translates to over 340 to 460 gallons of heating oil per home (Table 13). Most of the energy savings is in home heating, although lighting upgrades result in some electrical savings. The difference in savings rates between the two programs is most likely due to house size, with smaller homes primarily receiving retrofits through the low-income weatherization program (18). Table 13: Average EE&C savings per household in the Aleut region EE&C Program No. of Homes Average Energy Savings Annual Energy Savings Annual Fuel Savings1 Savings at $4.50/gal. Home Energy Rebate 12 rebates out of 31 audits (39% completion) 31% 64.3 MMBTU 462 gallons $2,078 per year Weatherization 145 homes 35% 47.4 MMBTU 341 gallons $1,532 per year Note: 1/ Fuel savings model assumes all heating is done with fuel oil. It does not include fuel saved in electrical generation due to reduced kWh use. Data source: (18). On a regional basis, residential EE measures account for over 12,000 MMBTU (1 MMBTU = 1 million British Thermal Units) annually in energy savings, which translates into nearly 89,000 gallons of heating fuel and over $450,000 in avoided fuel costs per year (Table 14). This does not include savings from lighting or appliance upgrades or other measures that reduce electrical use (or the diesel used to generate electricity). Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 48 See Chapter 3 for an estimate of the savings available from additional residential energy efficiency work in the region. Table 14: Estimated annual energy savings from residential EE&C, 2008-Apr 2014 Energy Efficient Housing Stock Estimated Annual Savings Community Occupied Homes 1 (2014 est.) New/ BEES- Certified Homes AHFC Home Energy Rebates Weather- ized through AHA Percent Energy Efficient Homes Annual Energy Savings 2 (MMBTU) Annual Fuel Savings (Gallons) Annual Fuel Cost Savings from EE 3 ($) Adak 54 - 0% - $ 0 Akutan 41 26 63% 1,232 8,849 $ 35,395 Atka 24 12 50% 569 4,084 $ 31,242 Cold Bay 14 - 0% - $ 0 False Pass 8 4 50% 190 1,361 $ 5,731 King Cove 118 4 49 45% 2,323 16,676 $ 71,541 Nelson Lagoon 14 8 57% 379 2,723 $ 17,017 Nikolski 27 13 48% 616 4,424 $ 30,970 Sand Point 164 5 5 42 32% 2,312 16,602 $ 85,502 St. George 53 7 13% 332 2,382 $ 18,439 St. Paul 263 9 43 20% 2,038 14,634 $ 76,098 Unalaska 834 10 7 41 7% 2,394 17,185 $ 79,740 Total Region 1,614 28 12 245 18% 12,385 88,921 $ 451,675 Notes: 1/ Occupied housing numbers from 2014 Alaska Housing Assessment. 2/ Estimated energy savings based on average energy savings for region achieved by HER and weatherization program participants in ARIS database, 2008- 2014. 3/ Fuel cost savings assumes all heating is with fuel oil. Assumes retail heating fuel costs for communities as of August 2014. Data sources: (15) (18) Non-Residential EE&C Program Participation Since 2005, a sequence of state and federal programs have funded community-scale, energy efficiency improvements in public facilities in rural Alaska, including indoor lighting retrofits, LED street lighting, heating system upgrades, insulation and sealing, and installation of programmable thermostats and other energy saving building controls. Most communities in the Aleut region have participated in at least one iteration of the programs (Table 15). See Chapter 3 for a discussion of the energy savings available from energy efficient lighting retrofits and other upgrades recommended in non-residential building audits. Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 49 Table 15: Participation in non-residential EE&C programs since 2008 Community Community EE&C Grants EE Lighting Upgrades Public Facility Energy Audits2 Private Commercial VEEP / EECBG VEUEM1 Interior Lighting LED Street Lighting School Audits Health Clinic Audits Sanitation System Building Audits Adak X Akutan X X Atka X Cold Bay X A False Pass X X A A 1 King Cove X X X A Nelson Lagoon Nikolski X X Sand Point A St. George X St. Paul X A Unalaska X X X 5 Notes: X=Completed, A=Audit, P=Planned or in Progress. 1/ Includes participation in VEUEM (2005 -2010), EECBG (2010- 2012) and VEEP (2010-2014). 2/ Information on completed retrofits not available. Data Sources: (16) (19) (20) Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 50 3 | E NERGY R ESOURCE & S AVINGS P OTENTIAL ENERGY RESOURCE POTENTIAL Phase I of the Regional Energy Planning process included an inventory of potential energy resources in the Aleut region. In Phase II, a preliminary assessment of resource potential was performed. The goal was to develop a consistent set of criteria for rating resource potential that could be applied across communities and regions. This assessment looks at the resource’s potential for producing energy savings from new, community- scale project development given the best available information (i.e. projects that are already in operation or under development are not counted towards the resource’s potential to generate additional savings in a community). These Potential ratings of Low (L), Medium (M), or High (H) are accompanied by a Certainty rating (also L, M, H) which indicates the amount of feasibility work that has been done or the availability of other information. Low certainty generally signifies that no reconnaissance or other resource assessment has been performed. See Appendix B for a detailed description of the criteria used in the analysis. Table 16 shows the results of this assessment for energy resources in Aleutian and Pribilof Island communities, including energy efficiency. Potential for energy savings from new, community- scale projects is generally greatest from energy efficiency, hydro, wind, heat recovery and geothermal energy, though differences exist across communities. See Appendix B for more details on each resource and a description of the criteria used in the analysis. Table 16: Energy resource potential and certainty for new community-scale projects Notes: Letters refer to resource potential: High (H), Medium (M), Low (L). Color indicates both potential and certainty (see color key). See Appendix B for an explanation of the criteria used in assessing resource potential. Adak Akutan Atka Cold Bay False Pass King Cove Nelson Lagoon Nikolski Saint George Saint Paul Sand Point Unalaska Biomass L L L L L L L L L L L L Geothermal M M M L L L L L L L L M Hydro H H H M H H L L L L L H Solar L L L L L L L L L L L L Wind H L M H L H L L H H H H Coal L L L L L L L L L L L L Oil & Gas L L L L L L L L L L L L Heat Recovery M M L M H L M L L L H H Energy Efficiency H M H H H H H H H H H H The first letter in each square represents resource potential. The subscript indicates the level of certainty in the resource potential rating. HighHL HM HH MedML MM MH LowLL LM LH Low Med High Color Key Potential 4Certainty 4 Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 51 SAVINGS POTENTIAL FROM INCREASED DIESEL EFFICIENCY Figure 7 in Chapter 2 shows recent diesel efficiency performance for the region’s public utilities. While it appears that diesel efficiency in the region is in the ballpark for most utilities, there is room for improvement that would save utilities money and fuel. If utilities below the AEA benchmarks improved system efficiency enough to meet them, they would save anywhere from $0.01 to $0.17/kWh in avoided fuel costs (Table 17, top). Collectively utilities would save 76,000 gallons of fuel oil annually—or $375,000 per year at 2014 fuel prices. Additional savings are available if all utilities improve diesel efficiency from where they are at now. A 10 percent increase in efficiency across the region would reduce annual fuel consumption by nearly 400,000 gallons, saving nearly $1.5 million per year in avoided fuel costs (Table 17, bottom). Table 17: Projected annual savings from meeting diesel efficiency benchmarks FY2014 Diesel Use & Efficiency Savings from Increase to Benchmark Efficiency Community (Ranked by total annual generation) Diesel Used for Generation (gals.) Diesel Efficiency (kWh/gal.) Increase to benchmark efficiency (kWh/gal.) New Fuel Use (gals.) Annual Fuel Savings (gals.) Annual Savings ($) Savings per KWh Saint Paul 270,929 13.9 14.5 260,549 10,380 $49,513 $0.01 Sand Point 219,998 13.9 14.5 210,918 9,080 $42,313 $0.01 Cold Bay 198,146 13.4 14.5 183,495 14,651 $76,036 $0.03 Adak 170,110 12.8 14.5 150,225 19,885 $98,628 $0.05 King Cove 153,210 14.1 14.5 149,461 3,749 $13,757 $0.01 Nelson Lagoon 39,158 8.8 12.5 27,519 11,639 $57,379 $0.17 Nikolski 20,940 9.9 12.5 16,615 4,325 $25,904 $0.12 Atka 10,765 10.1 12.5 8,711 2,054 $11,011 $0.10 All utilities 1,083,256 13.4 998,784 73,707 $363,531 $0.03 FY2014 Diesel Use & Efficiency Savings from 10% Increase in Efficiency Unalaska 3,068,848 15.7 17.2 2,789,862 278,986 $ 920,654 $ 0.02 Saint Paul 270,929 13.9 15.3 246,299 24,630 $ 117,485 $ 0.03 Sand Point 219,998 13.9 15.3 199,998 20,000 $ 93,199 $ 0.03 Cold Bay 198,146 13.4 14.8 180,133 18,013 $ 93,489 $ 0.04 Adak 170,110 12.8 14.1 154,645 15,465 $ 76,704 $ 0.04 King Cove 153,210 14.1 15.6 139,282 13,928 $ 51,116 $ 0.02 False Pass 60,967 12.8 14.0 55,425 5,542 $ 19,454 $ 0.02 Saint George 51,429 13.5 14.8 46,754 4,675 $ 33,756 $ 0.05 Akutan 40,944 15.5 17.1 37,222 3,722 $ 15,000 $ 0.02 Nelson Lagoon 39,158 8.8 9.7 35,598 3,560 $ 17,550 $ 0.05 Nikolski 20,940 9.9 10.9 19,036 1,904 $ 11,403 $ 0.05 Atka 10,765 10.1 11.1 9,786 979 $ 5,245 $ 0.05 All Utilities 4,305,444 15.0 16.5 3,914,040 391,404 $ 1,455,056 $ 0.02 Small Utilities 224,203 12.4 13.6 203,821 20,382 102,409 $ 0.04 Data source: (1) Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 52 According to AEA program managers, even small utilities are able to achieve diesel efficiencies of 14.0 and above. Every utility should be able to achieve the efficiency on the trend line in Figure 18 (21). Figure 18: Diesel Efficiency at Different Load Sizes, FY2013 PCE Data Source: (21) Even if a community produces most of its electricity with renewable energy—or hopes to in the future—optimizing diesel efficiency is important since almost any renewable resource needs to integrate with existing generators to ensure that power is available in the community when variable energy sources like wind or run-of-river hydro are offline. To integrate renewable energy systems, the primary powerhouse infrastructure must be in good working order and well maintained with adequate switchgear and controls installed. This is necessary so the integration of wind or hydro does not damage diesel equipment or lead to a marked decrease in generator efficiency that can result from operating at low capacity when the renewable resource is online (22). Another reason for getting the diesel powerhouse in order before pursuing renewable energy opportunities is that potential funders typically look at a community’s capacity for maintaining its current infrastructure (and for record keeping and business administration) before awarding funds for new projects. Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 53 SAVINGS POTENTIAL FROM ADDRESSING LINE LOSS Line loss refers to the percent of the electricity generated by a utility that is not sold. Line loss may be due to physical losses in the distribution network (possibly caused by deteriorating lines or old or poorly sized transformers) or from unmetered use. The result is a direct financial loss to the utility and, in the case of diesel generation, a waste of thousands of gallons of fuel each year. Line loss also affects the PCE rate available to a utility; losses above 12 percent reduce the PCE subsidy. In 2014, six communities in the region (shaded in brown in the table below) had a line loss above 12 percent, while four more (shaded in tan) had a line loss above 5 percent. Measurable savings would result from addressing the causes of line loss in these systems. Table 18: Line loss by community, FY2014 Community Total kWh Generated Line Loss Power Lost (kWh) Diesel Lost (Gallons) Adak 2,178,268 42% 919,673 71,793 Saint George1 693,419 19% 133,920 9,935 King Cove 4,513,471 17% 749,569 52,973 Akutan 636,366 15% 93,758 6,033 Saint Paul 4,347,407 14% 597,327 42,850 Nelson Lagoon 343,990 12% 42,550 4,846 False Pass 778,559 9% 70,763 5,541 Atka 510,211 8% 38,948 3,852 Cold Bay 2,660,684 8% 210,562 15,678 Nikolski 207,693 6% 12,688 1,279 Sand Point 3,919,804 5% 212,828 15,311 Unalaska 48,097,173 4% 1,919,551 122,498 Notes: 1/ St. George recently completed an RPSU project that should result in lower line loss for FY 2015. Data source: (1) Legend High Savings Potential (12%+ line loss) Medium Savings Potential (6% to 11% loss) Limited Savings Potential (5% or less line less) Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 54 SAVINGS POTENTIAL FROM EXPANDING COMMUNITY PCE USE The Power Cost Equalization program subsidizes electric rates of residents as well as eligible community buildings and facilities. The PCE statute defines a community facility as a water, sewer or charitable educational facility, public outdoor lighting, or a community buil ding that is not operated for profit, is open to the general public, and whose operation is not paid for by the State or Federal government or by a private commercial organization. AEA determines eligible community facilities based on applications and information submitted by the facility owner and utility provider. As with the residential PCE program, there are limits on the amount of PCE - eligible electricity (kWh) that may be used by a community facility. This monthly limit is set at 70 kWh per resident. In a community with 100 residents the total community facility use eligible for PCE cost reductions is 7,000 kWh per month, spread across all eligible community facilities. Communities in Table 19 are ranked by PCE savings potential. This is calculated based on average electricity use by community facilities in each community and the amount of electricity (kWh) still eligible for PCE subsidies in each community. Many communities are close to this limit, but a significant opportunity exists to save on public facilities’ electric bills in communities not at or near the community limit. Reasons communities in rural Alaska do not take full advantage of this subsidy include: turnover in utility management, lack of training, lack of coordination between community facility owners and utilities, and lengthy processing time of applications and rejection notices that do not provide information on why an application was rejected. AEA reports progress on addressing these issues. Table 19: Savings potential for community facilities through PCE Community/ Utility PCE kWh/person PCE Savings Potential Eligible Used Akutan 70 6 10+ buildings Sand Point 70 29 10+ buildings Unalaska 70 51 10+ buildings Adak 70 57 1 to 5 buildings Atka 70 57 At or near max Cold Bay 70 70 At or near max False Pass 70 68 At or near max King Cove 70 68 At or near max Nelson Lagoon 70 53 At or near max Nikolski 70 70 At or near max Saint Paul 70 70 At or near max Saint George 70 64 At or near max Data source: (1) Legend C 70 24 10+ buildings High Savings Potential (5+ buildings) Medium Savings Potential (1 to 5 buildings) Limited Savings Potential (At or near max) Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 55 SAVINGS POTENTIAL FROM INCREASED ENERGY EFFICIENCY Residential Energy Efficiency Only 18 percent of occupied homes in the region have participated in one of the state-funded residential energy efficiency programs since 2008 or been certified as meeting the BEES energy efficient building standard (see Table 14). If the remaining energy inefficient housing stock is upgraded (or in some cases rebuilt), the savings from residential EE&C could save another 41,000 MMBTU per year. This would save over 295,000 additional gallons of heating oil and nearly $1.5 million annually, at 2014 fuel prices. This does not include savings from lighting or appliance upgrades or other measures that reduce electrical use (or the diesel used to generate electricity). Table 20: Estimated energy savings and potential energy savings from residential EE&C EE&C Savings Achieved EE&C Savings Opportunity 1 Community Annual Energy Savings (MMBTU) Annual Diesel Savings (Gallons) Annual Fuel Cost Savings ($) Remaining Residential EE&C Opportunity Annual Energy Savings (MMBTU) Annual Diesel Savings (Gallons) Annual Fuel Cost Savings ($) Adak 0 - $ 0 100% 1,701 12,215 $56,431 Akutan 1232 8,849 $35,395 37% 429 3,078 $12,311 Atka 569 4,084 $31,242 50% 680 4,880 $37,328 Cold Bay 0 - $ 0 100% 454 3,263 $17,586 False Pass 190 1,361 $5,731 50% 98 702 $2,954 King Cove 2323 16,676 $71,541 55% 2,244 16,110 $69,111 Nelson Lagoon 379 2,723 $17,017 43% 220 1,583 $9,893 Nikolski 616 4,424 $30,970 52% 492 3,534 $24,735 Sand Point 2312 16,602 $85,502 68% 4,171 29,948 $154,233 St. George 332 2,382 $18,439 87% 2,137 15,341 $118,740 St. Paul 2038 14,634 $76,098 80% 8,077 57,990 $301,549 Unalaska 2394 17,185 $79,740 93% 20,412 146,556 $680,018 Aleut Region 12,385 88,921 $451,675 82% 41,114 295,198 $1,484,891 1/ Model assumptions: All non-BEES-certified, income-eligible homes are weatherized and remaining owner- occupied homes participate in Home Energy Rebate program. Based on average energy savings for region based on 2008-14 ARIS data. Assumes retail heating fuel costs for communities as of August 2014. Energy Efficient Lighting INDOOR LIGHTING UPGRADES Many communities have used Village Energy Efficiency Program (VEEP) or Energy Efficiency and Conservation Block Grant Program (EECBG) grants to complete lighting upgrades in one or more community buildings. VEEP is an AEA program that provides energy efficiency audit and upgrade services to Alaska communities with populations of 8,000 or less. EECBG was a national U.S. DOE program funded through the 2009 American Recovery and Reinvestment Act Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 56 that provided block grants to cities, communities, and Native tribes to develop, promote, implement, and manage energy efficiency and conservation projects. Based on statewide data for 33 small communities, annual savings from indoor lighting retrofits can save communities over $1,300 and 3,100 kWh of electricity per building per year. Savings achieved by three communities in the Aleut region are shown in Table 21. Lighting upgrades generally have shorter payback periods than other building efficiency measures making them smart investments even without the incentive of grant funding (19). While some of these savings have already been captured, there is still opportunity for additional savings in the region by investing in more energy efficient lighting upgrades—both in communities that did not participate in VEEP or EECBG programs and communities in which only some buildings (e.g. only schools or only city or tribally owned buildings) received lighting retrofits previously. The Community and Energy Profiles that start on page 70 include a list of non-residential buildings in each community. A good place for communities to start is by updating this building list with information on which buildings have received energy audits and which have had retrofits completed. Table 21: Savings from energy efficient lighting upgrades in 3 Aleutian communities One-time Investment Annual Savings Annual Electricity Saved (kWh) Average Simple Payback Period Average per community $6,963 $2,341 2,938 3.0 years Average per Building $2,611 $878 3,103 Total $20,888 $7,022 23,505 Based on lighting upgrades completed with VEEP and EECGB grants in Akutan, False Pass and King Cove (19). LED STREET LIGHTING Rural Alaska communities that have replaced street lights with LED lighting are saving an average of $10,000 per year each, with an average payback period of 3.7 years. In the Aleut region, at least two communities have completed LED streetlight retrofits. Estimated savings are shown in Table 22. Table 22: Savings from LED street lighting retrofits in 2 Aleutian communities Community One-time Investment Annual Savings Annual Electricity Saved (kWh) Average Simple Payback Period King Cove $35,184 $10,532 40,506 3.3 years Unalaska $153,500 $65,497 198,475 2.3 years Total $188,684 $76,028 238,981 2.5 years Based on VEEP and EECBG-funded lighting upgrades completed through 2013. Data source: (19) Public Facility and Commercial Energy Audits Only five of the region’s schools and a small number of other community buildings (mostly in St. Paul) have been audited through AHFC’s Commercial Energy Audit (ACEA) program. Because the program covers the cost of the audit but does not pay for retrofits, it is believed that most of Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 57 the potential savings identified in the commercial energy audits performed in Alaska have not been achieved. This represents a huge missed savings opportunity. If just the most cost-effective retrofits are completed and some behavioral changes (like setting back thermostats) public building owners can typically save 20 percent on annual energy costs (23). Privately-owned buildings are eligible for whole-building energy audits through AEA’s Commercial Building Energy Audit (CBEA) program. Like the public building audits performed by AHFC, the CBEA program covers the cost of the audit (up to a limit based upon the size and type of building), but does not pay for retrofits. Though most private commercial building audits are done in urban Alaska, a few have been completed in Aleutian communities (see Table 15). As with public building audits, the lack of grant funding to pay for retrofits up front has meant that a small minority of audits are followed by recommended upgrades. In buildings where energy efficiency investments have been made, building owners typically cut their overall energy use by one-third, with average simple paybacks of just over six years. Table 23: Savings potential for public and commercial facilities Savings from Behavioral Changes Only Behavioral Changes plus the Most Cost-Effective Retrofits Savings from Implementing All Audit Recommendations 10-15% Savings 15-25% Savings 25-35% Savings Source: (23) Water and Sewer Sanitation systems are one of the single largest energy users i n rural communities, accounting for 10 to 35 percent of a community’s energy use. Alaska Native Tribal Health Consortium (ANTHC) estimates that for every one dollar spent on energy retrofits of rural sanitation facilities (including the cost of audits), there will be a 50 cent return each year to communities plus a 50 cent annual return to the State’s operating budget through lower PCE payments (24). ANTHC has performed energy audits of sanitation facilities in many small communities in Interior, Southwest and Western Alaska, and is interested in expanding its focus to the Aleutians. Table 24 shows average cost and savings based on audits of water systems in over 50 rural communities. Table 24: Potential savings from sanitation system energy efficiency Number of Water Systems Audited One Time Investment per Facility Electricity Savings (kWhs) Diesel Savings (Gallons) Cost Savings ($) Average Simple Payback (years) 51 $107,214 22,010 2,663 $25,404 4.2 Data Source (24) Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 58 4 | S TAKEHOLDER O UTREACH Public outreach and stakeholder engagement are major components of the second phase of AEA’s regional energy planning process. In the Aleutian and Pribilof Islands region, these goals were met through a variety of activities:  Community/Utility Interviews (Summer 2015)  Aleutian Energy Summit (March 2015)  Breakout Sessions at SWAMC Annual Meeting (2013- 2015)  Online Survey (Spring 2014)  Project website: www.aleutiansenergy.org (Since 2014)  Community and Utility Site Visits (2012-13) OUTREACH ACTIVITIES Community/Utility Interviews | May-August 2015 The community-level outreach for Phase II included telephone interviews with representatives from each community in summer 2015. The purpose of the interviews was to update information on energy projects and priorities. See Appendix A for a list of interviews. Aleutian Regional Energy Summit | March 2015 The capstone event of Phase II was a regional energy summit held on March 3, 2015. Over 20 representatives from local and regional organizations and industry attended the summit, which was held in conjunction with the SWAMC annual conference in Anchorage. Ten communities were represented (all but Nikolski and False Pass). See Appendix A for a list of participants and speakers. Summit topics were tailored to the energy issues and priorities identified through previous outreach and research. They included energy efficiency, powerhouse efficiency, wind integration, and project development and financing. Additional sessions highlighted success stories from the region with speakers from King Cove and TDX Power, and provided brief overviews of energy programs and services available from resources agencies. Speakers included AEA technical staff, Alaska Industrial Development and Export Authority (AIDEA), Siemens, Alaska Housing Finance Corporation (AHFC), UAF Interior-Aleutians Campus, USDA Rural Development, US Department of Energy, Alaska Native Tribal Health Consortium, and the state’s Bulk Fuel Loan Program. The summit concluded by polling participants on priorities for short, medium and long-term projects at the regional level. Due to a technical failure, only partial results are available. Overall the survey results show that among summit participants there is the greatest urgency for actions to maximize energy efficiency, followed by maintaining and improving existing infrastructure, and investigating and developing renewable energy generation opportunities, though there was strong support (over 50%) for pursuing all strategies (Figure 19). Community representatives were also asked about support for and timing of specific energy projects in their communities. Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 59 This input has been used to develop the list of projects and priorities in Chapter 5 and is re flected in the draft Energy Roadmap in the Executive Summary. Figure 19: Prioritization of regional energy strategies Online Survey | Feb-April 2014 An online survey of community and regional stakeholders was conducted at the end of Phase I to identify any errors in the Phase I Resource Inventory and gather input on the most broadly supported energy projects and priorities. SWAMC reached out to 72 stakeholders by phone and email, contacting each up to three times, to publicize the release of the Phase I document, request their review, and solicit input through an online survey. In all, 85 percent of the stakeholders contacted confirmed that they had received the Phase I inventory; 40 percent took time to review it; and 63 percent completed the online survey. Those who took the survey represented a cross- section of the region, with at least one stakeholder from every community, except Nikolski, and multiple respondents from larger communities. (See Appendix A for a list of survey respondents). Many individuals expressed enthusiasm for the project and a desire to be involved. Overall, they emphasized the need for improved energy efficiency at all levels (residential, community, and businesses) and expressed significant support for renewable energy projects (wind, hydro, and tidal, etc.). Respondents emphasized that cost reduction in heating, followed by electricity, and travel to and from communities as areas of greatest need for energy relief. Every community ranked at least four of the specific projects identified for their community as important to extremely important. Complete survey results are published in the May 2014 Phase II Survey Results report available on the project website (www.aleutiansenergy.org). Based on survey input, the following list of short term and long term strategies and priorities emerged from the analysis of survey results. SHORT TERM: FOCUS ON AFFORDABLE ENERGY (LOWER FUEL AND ELECTRICITY COSTS)  Complete and maintain current energy projects  Continue with weatherization and other energy efficiency and conservation efforts  Look at LNG  Improve diesel generator efficiency Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 60 LONG TERM: FOCUS ON RELIABLE, LOCAL, SUSTAINABLE ENERGY  Develop alternative energy sources (wind, hydro, geothermal, heat pumps, tidal)  Prioritize energy efficiency and conservation  Upgrade distribution systems Community and Utility Site Visits | 2012-13 Phase I of the project involved in-person site visits to most of the communities in 2012 and 2013 by Andy Baker of Your Clean Energy, LLC to assess existing resources and potential for renewable energy systems. Detailed findings from these visits are summarized in the Phase I Resource Inventory available on the project website (www.aleutiansenergy.org). NEXT STEPS Create Regional Energy Committee to Advance Shared Goals The creation of energy committees or working groups has been recommended by AEA as a way to implement local and regional priorities and continue the work of energy planning into the future. Broad goals and objectives include:  Bring energy champions together from across the region.  Identify similar local priorities and opportunities to create economies of scale.  Share local knowledge and capacity to create the structure and relationships needed to carry ideas forward.  Seek broad sustainable engagement, including youth.  Keep a clear focus on regional energy goals and priorities.  Look for ways stakeholders can support the long-term sustainability of energy working groups and regional energy planning. Regional energy committees and stakeholder groups have been instrumental in addressing energy issues and advancing shared goals in Southeast Alaska and the Northwest Arctic Borough, and regional groups are now being established in the Kodiak Island Borough and Bering Straits region. Effort is also going into the creating or reviving working groups focused on specific resources (energy efficiency and biomass) in the Copper River region. Despite the large distances that separate them, communities and utilities in the Aleut region share many issues related to energy development and have similar resources. Those hoping to develop new hydroelectric projects could learn from successful projects in Atka, Akutan, and King Cove. Similarly, there have been successful wind projects in St. Paul and Sand Point that could be a template for development of wind energy in other communities of the region. The challenge of making an energy committee work in the Aleut region is the remote and fragmented nature of the region. Most meetings could be held by teleconference with most communication by email and telephone. An annual face-to-face meeting would be useful in maintaining momentum and keeping an energy working group together. A pre-conference meeting in Anchorage a day before the start of the SWAMC Economic Summit and Membership Meeting may be the best time for such a gathering. Steps to establish a regional energy committee in the Aleut region include: Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 61  Engage regional and subregional organizations and government entities to ensure a regionwide perspective in energy planning and integrate work on energy priorities into the mission and daily operations of governing bodies and service providers. across the region.  Seek representation of all communities by soliciting resolutions from local governing bodies appointing a local energy champion to the committee  Secure organizational support from regional entities for holding regular meetings or teleconferences and an annual face-to-face meeting. Based on level of interest, an Aleutian and Pribilof Islands Energy Committee presents an opportunity to work on regional goals and shared priorities including: maximizing energy efficiency, maintaining and upgrading existing infrastructure, transitioning to locally produced energy resources, and promoting community sustainability by looking for all opportunities to reduce the cost of energy in the Aleut region. Aleutian & Pribilof Islands Regional Energy Plan Phase II: Stakeholder Engagement and Public Input | 62 5 | E NERGY P ROJECT S & P RIORITIES At least 18 energy-related projects are planned or in progress in the region. The list in Table 25 is based on information provided by project sponsors as well as data published in the Phase I report, Renewable Energy Fund applications and status reports, and project lists from AEA. Completed Projects are not shown. Active projects or those that have been scheduled or funded are highlighted in brown in the table below. The list also includes community or utility energy priorities that are not yet associated with a specific project. These have been identified through discussions with community leaders and utility managers. The timeframes shown indicate a best guess for project timing given available resources, readiness of the technology, and competing priorities.  Short range: expected to start within 1-5 years  Medium range: expected to occur between 5-10 years  Long range: expected to occur beyond 10 years Table 25: Energy projects planned or in progress Project Communities Lead Entity Status Scope / Next Steps Output Timing Cost Funding Planning and Collaboration Regional Energy Planning All SWAMC, AEA Active Economic and technical analysis of projects and startup of Energy Committee. Identification of viable energy projects with broad support. Implementation plan that includes regional Energy Committee. Ongoing AEA Energy Committee All SWAMC, AEA Planned Appointment of representatives by communities. Seek organizational support for regular teleconferences and annual meet up. Regional forum for sharing information on energy projects, collaboration on common issues and barriers, continuation of energy planning into the future. 2015-16 startup ARDOR, AEA, with Regional Support Bulk Fuel Purchase Cooperative All Priority Identify interested communities and review existing Lower bulk fuel costs through competitive bidding on higher Medium Aleutian & Pribilof Islands Regional Energy Plan Phase II: Stakeholder Engagement and Public Input | 63 Project Communities Lead Entity Status Scope / Next Steps Output Timing Cost Funding structures and studies to decide on path forward. volumes and administrative savings. Renewable Energy Alternatives Atka City Priority Assess renewable energy options for fish plant and/or for residential heating Cost savings focused on space heating and reduced dependence on fossil fuels. Short Oil and Gas Bulk Fuel Upgrade St. George AEA Planned Conceptual Design Conceptual Design Report (CDR) for new bulk fuel tank farm infrastructure Short AEA Partial funding Bulk Fuel Upgrade Cold Bay, St. Paul, Sand Point AEA Planned Medium AEA 10-year plan: funding not guaranteed LNG Demonstration Project Unalaska City Priority Assess feasibility of importing LNG by tanker for use in generating electricity, including performance testing of LNG generator. Determination to proceed or table based on current costs and technology. Short Bulk Fuel Storage St. George, St. Paul City Priority Share fuel storage through inter-island ferry. Install new tanks for aviation fuel at or near airport (St. Paul) Diesel Efficiency and Heat Recovery Rural Power System Upgrade Adak AEA,TDX Power Planned Properly size diesel plant to address inefficiencies created by hugely oversized system in poor condition. Improved efficiency and cost savings through right-sizing system and ability to integrate with local hydro resources. Medium AEA 10-year plan: funding not guaranteed Aleutian & Pribilof Islands Regional Energy Plan Phase II: Stakeholder Engagement and Public Input | 64 Project Communities Lead Entity Status Scope / Next Steps Output Timing Cost Funding Rural Power System Upgrade and Heat Recovery St. George AEA Active Improved diesel efficiency and cost savings. Short $6,035,821 AEA Partial funding St. Paul Fuel Economy Upgrade St. Paul City Utility Active Design upgrade and extension of heat recovery loop to work with wind-diesel system. Lower space heating costs and reduced fossil fuel dependence. Short (2014) $114,834 AEA REF 3, Local Match Waste Heat Recovery Feasibility and Conceptual Design Cold Bay G&K Electric Utility / Aleutians East Borough Active Assess feasibility of implementing heat recovery at power plant. Lower space heating costs and reduced dependence on fossil fuels. Short (2016) $35,000 AEA REF 6, Local Match Integrate private powerhouses into the city grid Unalaska City Active Rural Power System Upgrade St. Paul City Priority Upgrade diesel power system. Determine cause of line loss. Establish emergency energy generation for homes and essential services Cost and fuel savings from diesel efficiency and lower line loss. Improved safety and emergency preparedness. Rural Power System Upgrade False Pass City Priority Address high line losses and diesel efficiency Cost and fuel savings from diesel efficiency, lower line loss. Improved safety. Transformer/Distribution System Upgrade Nelson Lagoon Tribal Council Critical Need Address high line loss through upgrade of distribution system and replacement of transformers that are beyond useful life. Cost and fuel savings from lower line loss. Improved safety. Waste Heat Recovery Feasibility False Pass City Priority Assess feasibility of delivering waste heat to school. Determination to proceed or table based on current costs and technology. Aleutian & Pribilof Islands Regional Energy Plan Phase II: Stakeholder Engagement and Public Input | 65 Project Communities Lead Entity Status Scope / Next Steps Output Timing Cost Funding Waste Heat Recovery Feasibility Unalaska City Priority Expand number of buildings heated with waste heat. Determination to proceed or table based on current costs and technology. Medium Successor Operator Training Adak, Nelson Lagoon Priority Look into AEA’s Utility operator successor training program. Training for next generation of operators to ensure well- maintained powerhouse with good diesel efficiency. Short Free AVTEC training (excluding travel) Biomass Wood Biomass Pre- feasibility Nelson Lagoon Tribal Council Priority Assess whether sufficient wood biomass exists for community- scale project Determination to proceed or table based on current costs and technology. Waste-to-Energy Feasibility Unalaska City Priority Assess feasibility of using of solid waste incineration for biomass energy production. Determination to proceed or table based on current costs and technology. Geothermal Akutan Geothermal Development Final Design Akutan City Utility Active Drilling of confirmation well in Hot Springs Bay Valley and completion of final design and permitting, power sales agreement with Trident Seafood, business and operations plan. Establish precise location and size of resource. Potential for 2-3 MW power plant. Short $3,050,000 REF 4 ($5.82 million total REF). Total project cost estimated at $65 million. AEA REF 2/3/4, Local Match (US DOE grant will support drilling costs) Heat Pump Feasibility Unalaska City Priority Study costs and benefits of heat pumps for space heating. Better understanding of heat pump technologies and at what electrical rates they become economic in Unalaska. Hydro Atka Dispatchable Heat Design & Construction Atka City Active / On Hold Start construction of heat project once PLC Cost savings and reduced dependence on fossil Short $135,289 REF 7. (Total $207,874) AEA REF 3/7, Local Match Aleutian & Pribilof Islands Regional Energy Plan Phase II: Stakeholder Engagement and Public Input | 66 Project Communities Lead Entity Status Scope / Next Steps Output Timing Cost Funding and controls have been upgraded. fuels from heating 7 community buildings with excess hydroelectric energy. Waterfall Creek Hydro Final Design & Construction King Cove City Active Complete construction of 375 kW run-of-river hydro with transmission to existing Delta Creek hydro powerhouse. Displace diesel used for electric generation at the city utility and by selling dispatchable power to Peter Pan Seafoods. $3.90 million REF 6. ($4.50 million total) AEA REF 5/6, Local Match Pyramid and Shaishnikof Creeks Hydro Feasibility Unalaska City Priority (Note: City says this is no longer a priority.) Feasibility assessment of potential 260 kW (Pyramid Creek) to 700 kW (Shaishnikof Creek) run-of-the-river sites. Determination to proceed or table based on current costs and technology. Small-scale Run-of-River Hydro Feasibility False Pass City, AEA Priority Feasibility assessment of potential 140-160 kW run-of-river hydro resource. Determination to proceed or table based on current costs and technology. AEA REF 9 application submitted Hydrokinetic (Tidal) Tidal Energy Pre- feasibility Nelson Lagoon Tribal Council Priority Monitor emerging tidal power developments with eye to potential project under dock. Determination to proceed or table based on current costs and technology. Ongoing Solar Solar Energy Pre-feasibility Unalaska City Priority Monitor success of solar installations at other locations to determine efficacy of solar in Unalaska Determination to proceed or table based on current costs and technology. Solar Streetlight Feasibility Atka City Priority Assess feasibility of solar-powered streetlights. Determination to proceed or table based on current costs and technology. Solar Energy Feasibility Nelson Lagoon, St. George Priority Assess feasibility of community-scale solar Determination to proceed or table based Aleutian & Pribilof Islands Regional Energy Plan Phase II: Stakeholder Engagement and Public Input | 67 Project Communities Lead Entity Status Scope / Next Steps Output Timing Cost Funding to reduce costs and/or diesel dependence. on current costs and technology. Wind Atka Wind Energy Feasibility Atka Active Installed several met towers in 2015. Complete one year of data collection and draft feasibility study. Determination to proceed or table based on current costs and technology. Short APICDA support Cold Bay Wind Energy Feasibility Cold Bay G&K Electric Utility (IPP) Active Complete feasibility assessment with full year of data from met tower installed in 2012. Determination to proceed or table based on data from met tower site. Short $104,075 AEA REF 4, Local Match Sand Point Excess Wind Utilization Sand Point TDX Sand Point Generating Active Install electric boilers at the school and clinic to use excess wind energy for space heating, and integrate building energy use data into the plant SCADA system. Cost savings and reduced fuel consumption from use of wind energy now being dumped and ability to measure and optimize building performance through SCADA system. Short $383,900 AEA REF 8, Local Match Sand Point Energy Storage Design & Construction Sand Point TDX Sand Point Generating Active Install an inverter and battery bank to store excess wind energy. Cost savings and reduced fuel use through increased utilization of wind energy and ability to run at “wind only” for up to 30% of the year. $1,397,403 AEA REF 7, Local Match St. Paul Flywheel (add-on to Wind-Diesel Construction project) St. Paul TDX Corp. (IPP) Active Complete testing of flywheel for storage of excess wind energy. Install met tower and additional secondary loads. Cost savings and reduced fuel use through increased utilization of wind energy. $2.1 million total wind- diesel project (plus $1.5 million for turbines) AEA REF 3, US DOE, Local Match King Cove Wind Energy Feasibility King Cove NA Identify new test sites in Delta Creek Valley; monitor technology to find best system for strong winds; complete study. Determination to proceed or table based on current technology for strong/ turbulent winds. Aleutian & Pribilof Islands Regional Energy Plan Phase II: Stakeholder Engagement and Public Input | 68 Project Communities Lead Entity Status Scope / Next Steps Output Timing Cost Funding Nelson Lagoon Wind Energy Feasibility & Conceptual Design Nelson Lagoon Utility Cooperative Active Complete avian study and draft CDR based on data collected from modified 40’ monopole tower. Determination to proceed or table based on data from met tower site and environmental (avian) issues. Short (2015) $104,075 AEA REF 4, Local Match St. George Wind Farm Construction / Wind Turbine Replacement St. George City Active Replace 95 kW burned- out wind turbine wind turbine with one of similar size and type. Ensure proper integration with new power plant. Lower energy costs and reduced dependence on fossil fuel from properly integrated wind energy. Short (Oct 2015) AEA REF 1 Nikolski Wind-Diesel System Redesign, Construction and Commissioning Nikolski Native Village Priority Complete integration and commissioning of 65 kW Vestas V15 wind turbine in coordination with AEA wind program managers. Cost savings and reduced diesel dependence from having a functioning wind-diesel power system. $331,240 (estimated cost in 2012) Transportation UMC Dock Project Unalaska City Active Complete UMC dock project. Trans-load Dock and Access Road Akutan City Priority Add trans-load dock and build access road between village and harbor. Potential for reduced bulk fuel transportation costs. Long $1.78 million dock. $22.13 million road Protected Marine Infrastructure Development Cold Bay City Priority Develop protected marine infrastructure. Improved safety. Potential for reduced bulk fuel transportation costs. Harbor Reconstruction and Dredging St. George City Priority Improved safety. Potential for reduced bulk fuel transportation costs. Aleutian & Pribilof Islands Regional Energy Plan Phase II: Stakeholder Engagement and Public Input | 69 Project Communities Lead Entity Status Scope / Next Steps Output Timing Cost Funding Energy Efficiency & Conservation Waste and Sewer Plant Design & Construction Unalaska ANTHC Active Finish construction and monitor efficiency of new water and wastewater plants. Reduced costs and fossil fuel dependence through improved energy efficiency of sanitation system. Short Improve energy efficiency of residential, community, and commercial buildings All Priority Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | 70 6 | C OMM UNITY AND E NERGY P ROFILES This section contains profiles for communities in the Aleutian region. The first part contains general information about the location, economy, historical and cultural resources, planning, demographics, contacts and infrastructure in each community. It provides a broad overview of community size, location and resources to give context to the energy profile. The second part of each profile is the energy profile, which provides an overview of energy production and distribution. It is intended to provide a snapshot of local energy conditions. The energy profile also includes a partial inventory of non-residential buildings in the community and its participation in state and federal energy efficiency programs. The data sources used to compile the profiles are shown in Appendix E. Though based on the latest available data from state and federal sources, we know that not all information is accurate due to sampling and reporting errors. To try to correct these inaccuracies, we emailed draft versions of the Community and Energy Profile to contacts in each community in the spring and summer of 2015. The profiles in this report include the revisions we received. The summary of community Energy Priorities and Projects on the first page of each profile has also been updated from the Phase I report based on the public input gathered in Phase II, including interviews with community leaders where possible. Community Profile: Adak Incorporation 2nd Class City Location Longitude ‐176.6286 Latitude 51.8725 ANCSA Region Aleut Corporation Borough/CA Aleutians West Census Area School District Aleutian Region School District AEA Region Aleutians Alaska Native Name (definition)Taxes   Type (rate) Per‐Capita Revenue AdaQ ("Father") Sales (4%), Bed (5%), Raw Fish (2%) 2,060$               Historical Setting / Cultural Resources Economy Climate Avg. Temp. Climate Zone Heat. Deg. Days 41.1 7 9,046 Year Notes Community Plans Year Local Contacts Phone Fax clerk@adak‐ak.gov 907‐592‐4500 907‐592‐4262 907‐277‐1440 907‐277‐1446 receptionist@aleutcorp.com 907‐561‐4300 907‐276‐3924 Demographics 2000 2010 2013 Population 316 326 Percent of Residents Employed 65% Median Age 36 46 Denali Commission Distressed Community No Avg. Household Size 33Percent Alaska Native/American Indian (2010)5.52% Median Household Income $52,727 $88,750 Low and Moderate Income (LMI) Percent  (2014)32.6% Electric Utility Generation Sources Interties PCE? Yes Landfill Class 3 Permitted?Yes Location Water/Wastewater System City of Adak Homes Served System Volume Water Sewer Energy Audit? Notes Access Road Air Access Runway 2 runways: 7,790'x200' & 7,605'x200' Dock/Port Barge Access?Yes Ferry Service?No Notes Adak is located on Kuluk Bay on Adak Island. It lies 1,300 miles  southwest of Anchorage and 350 miles west of Unalaska or its  port Dutch Harbor in the Aleutian Island Chain. Adak is the  southern‐most community in Alaska. Local government, trade, and transportation/warehousing are  main employers. There are four fishing permits for the village.  Fish processing/final sales. Natural Hazard Plan Aleut Corporation TDX Adak Generating LLC Diesel No The Aleutian Islands were historically occupied by the  Unangas. The Native population continued to actively hunt  and fish around the island over the years, until World War II  broke out.  Adak was tje site of a Naval Air Station, which  closed on March 31, 1997. In 2001, the community formed as  a second‐class city. As of 2009, all naval installations were  closed. Ownership of the facilities passed to the Aleut  Corporation and the City of Adak. Energy Priorities and Projects Workforce development/utility op. training; Wind ‐ id less  turbulent sites; Investigate geothermal potential; secure  funds/continue FS for Bonnie Rose Lake Hydro; Heat recovery  for community bldgs.; Space heating strategy Email  City of Adak Eastern Aleutian Tribes, Inc N/A Piped Yes Adak No Publicly owned; Asphalt Yes Piped 220 Energy Profile: Adak Diesel Power System Power Production Utility Diesel (kWh/yr)2,178,268 Avg. Load (kW)200 Engine Make/Model Condition/Hrs Gen Capacity Wind (kWh/yr)0 Peak Load (kW)904 Unit 1 Caterpillar Good/375 500 Hydro (kWh/yr)0 Efficiency (kWh/gal)13 Unit 2 Caterpillar Poor/33,770 1135 Total (kWh/yr)2,178,268 Diesel Used (gals/yr)170,110 Unit 3 Caterpillar Poor/Destroyed 800 Unit 4 Caterpillar Poor/35,427 800 Unit 5 Caterpillar Poor/40,155 800 Line Loss Heat Recovery? Upgrades Priority Projects Status RPSU Powerhouse High RPSU Distribution High Outage History/Known Issues Operators No. of Operators 1 PPO Electric Rates ($/kWh) Cost per kWh Sold ($/kWh)  Maintenance Planning (RPSU)Good Rate with PCE $0.63 Fuel Cost $0.67 Electric Sales No. of Customers kWh/year kWh/Customer Residential Rate$1.44 Non‐fuel Cost $0.30 Residential 90 345,241 3,836                   Commercial Rate Total Cost $0.97 Community 7 319,341 45,620                 Fuel Prices ($)Utility/Whlsale Retail Month/Year Commercial 105 594,013 5,657                   Diesel (1 gal)$4.88 $4.62 6‐13; 8‐13 Utility Use 0 Other Fuel? (1 gal) Gasoline (1 gal) Propane (100#) Wood (1 cord) Pellets Discounts? Alternative Energy Hydroelectric Wind Diesel Biomass Solar Geothermal Oil and Gas Coal Emerging Tech Heat Recovery Energy Efficiency Bulk Fuel Purchasing Deliveries/Year Gallons/Delivery Vendor(s) Tank Owner Fuel Type(s) Capacity Age/Condition By Barge Adak Petrol. Adak Petroleum #2 ULS Diesel 20,000,000 By Air Cooperative Purchasing Agreements Bulk Fuel Upgrade Priority Project Status Notes TDX Adak Generating LLC 42.2% No Facilities damaged in fire; Serious risks to health & safety.  Training/Certifications Potential Status High Feasibility Study Projects Adak Hydroelectric  Pending Medium Medium High Preliminary Design Low Not Rated Low Low Wind Data Collection  High CompleteEECBG 27% 25% 47% 0% Residential Community Commercial Utility Use Electric Sales by Customer Type (kWh/year) 0 500 1000 1500 2000 2500 3000 3500 2010 2011 2012 2013 2014Electric Generation (MWh)Diesel Hydro Wind Energy Profile: Adak Housing Units Occupied Vacant % Owner‐Occup.Regional Housing Authority Weatherization Service Provider 54 770 37% Housing Need Overcrowded 1‐star Energy Use Average Home Average Avg. EUI  3.7% N/A Energy Rating Square Feet (kBTU/sf) Data Quality N/A N/A N/A Street Lighting Owner Number/Type Retrofitted? Year City of Adak Non‐residential Building Inventory Building Name or Location Year Built Square Feet Audited? Retrofits Done? In ARIS? Bering Hill Chapel/Tsunami Shelter 15,000 No City Hall 77,100 No City Shop 8,081 No EMS Bldg./Line Shack 16,800 No Lift Station 12 168 No Lift Station 13 180 No Lift Station 7 288 No Lift Station 9 100 No Maintenance Shop/Aleut Corp.?/telephone 12,000 (?) Yes Pat Kelly Airport Terminal 15,000 No Pressure Reducing Valve 1 912 No Sewer Treatment Plant 2,500 No SRE Bldg. 5,000 Yes Aleutian HA Aleutian HA Low Notes 0 3 0 110 117 503 15 0 Earlier 1940s 1950s 1960s 1970s 1980s 1990s 2000‐11 Age of Housing Stock                                       0%0% 100% Retrofitted BEES Certified Untouched Energy Efficient Housing Stock Community Profile: Akutan Incorporation 2nd Class City Location Longitude ‐165.7731 Latitude 54.1356 ANCSA Region Aleut Corporation Borough/CA Aleutians East Borough School District Aleutians East Borough School District AEA Region Aleutians Alaska Native Name (definition)Taxes   Type (rate) Per‐Capita Revenue Achan‐ingiiga ("I made a mistake") Raw Fish (1.5%) 1,490$               Historical Setting / Cultural Resources Economy Climate Avg. Temp. Climate Zone Heat. Deg. Days 40.9 7 8,554 Year Notes Community Plans Year 2005 Local Contacts Phone Fax akutanadmin@gci.net 907‐698‐2228 907‐698‐2202 907‐277‐1440 907‐277‐1446 akutanaleuttribe@hotmail.com 907‐698‐2300 907‐698‐2301 Demographics 2000 2010 2013 Population 713 1,027 Percent of Residents Employed 92% Median Age 41 45 Denali Commission Distressed Community No Avg. Household Size 33 Percent Alaska Native/American Indian (2010)5% Median Household Income $33,750 $38,333 Low and Moderate Income (LMI) Percent (2014)63.4% Electric Utility Generation Sources Interties PCE? Yes Landfill Class 3 Permitted?No Location Water/Wastewater System Aleutians East Borough Homes Served System Volume Water 95 Sewer Energy Audit? Notes Access Road Air Access Runway 4,500' x 75' Dock/Port Barge Access?Yes Ferry Service?Yes Notes Maintain and upgrade hydro at Town Creek; Monitor tidal and  wave power opportunties; Complete harbor projects; Build  access road between village and harbor; Improve airport runway Piped Piped 50,001‐100,000  gpd (water) Yes No Publicly owned; asphalt Yes Akutan Email  No Akutan began in 1878 as a fur storage and trading port. The  Pacific Whaling Co. built a whale processing station across from  Akutan in 1912, which closed in 1939. After the Japanese  attacked Unalaska in 1942, the U.S. gov't evacuated the area.  The village was re‐established in 1944, though many did not  return, changing the traditional lifestyle. The majority of the  population is transient fish processing workers. Energy Priorities and Projects Akutan is located on Akutan Island in the eastern Aleutians,  one of the Krenitzin Islands of the Fox Island group. It is 35  miles east of Unalaska and 766 air miles southwest of  Anchorage Manufacturing provides more than 50% of employment with  local government and trade as other top employers.  Natural Hazard Plan City of Akutan Eastern Aleutian Tribes, Inc. Native Village of Akutan City of Akutan Diesel; Hydro City of Akutan Community Plan Energy Profile: Akutan Diesel Power System Power Production Utility Diesel (kWh/yr)636,366 Avg. Load (kW)59 Engine Make/Model Condition/Hrs Gen Capacity Wind (kWh/yr)0 Peak Load (kW)131 Unit 1 John Deere Fair/10,342 117 Hydro (kWh/yr)0 Efficiency (kWh/gal)16 Unit 2 John Deere Poor/44,980 150 Total (kWh/yr)636,366 Diesel Used (gals/yr)40,944 Unit 3 John Deere Good/6,267 140 Unit 4 Line Loss Heat Recovery? Upgrades Priority Projects Status RPSU Powerhouse Med. RPSU Distribution Low Outage History/Known Issues Operators No. of Operators 8  Maintenance Planning (RPSU)Acceptable Electric Rates ($/kWh) Cost per kWh Sold ($/kWh) Electric Sales No. of Customers kWh/year kWh/Customer Rate with PCE $0.14 Fuel Cost $0.32 Residential 41 176,745 4,311                   Residential Rate$0.32 Non‐fuel Cost $0.42 Community 14 143,868 10,276                 Commercial Rate Total Cost $0.74 Commercial 18 196,674 10,926                 Fuel Prices ($)Utility/Wholesale Retail Month/Year Utility Use 25,321 Diesel (1 gal)$4.03 $4.00 6‐13; 8‐14 Other Fuel? (1 gal) Gasoline (1 gal) Propane (100#) Wood (1 cord) Pellets Discounts? Alternative Energy Hydroelectric Wind Diesel Biomass Solar Geothermal Oil and Gas Coal Emerging Tech Heat Recovery Energy Efficiency Bulk Fuel Purchasing Deliveries/Year Gallons/Delivery Vendor(s) Tank Owner Fuel Type(s) Capacity Age/Condition By Barge City of Akutan #2 Diesel 72,400 Good By Air Trident Seafood #2 Diesel 1,786,590 Cooperative Purchasing Agreements Bulk Fuel Upgrade Priority Project Status Notes City of Akutan 14.7% No Training/Certifications PPO,  Hydro,  BF Book,  Clerk,  BF  Manager Potential Projects Status High Town Creek Hydroelectric Plant, 105 kW Operational Low Low Fish byproducts used by Trident Seafood Corp. Pending Medium Exploration at Hot Springs Valley Reconaissance Low Low Not Rated Medium Medium EECBG, AHFC‐R Both Complete 33% 27% 36% 5% Residential Community Commercial Utility Use Electric Sales by Customer Type (kWh/year) 0 100 200 300 400 500 600 700 2010 2011 2012 2013 2014Electric Generation (MWh)Diesel Hydro Wind Energy Profile: Akutan Housing Units Occupied Vacant % Owner‐Occup.Regional Housing Authority Weatherization Service Provider 18 4 44% Housing Need Overcrowded 1‐star Energy Use Average Home Average Avg. EUI  N/A N/A Energy Rating Square Feet (kBTU/sf) Data Quality N/A N/A N/A Street Lighting Owner Number/Type Retrofitted? Year Non‐residential Building Inventory Building Name or Location Year Built Square Feet Audited? Retrofits Done? In ARIS? Akutan K‐12 School 11,425 Yes Clinic 1,448 No Nurse Duplex 941 No Public Library/Museum 2,860 No SRE/Sand Storage Bldg. (Heated) 7,150 Yes VPSO Duplex 941 No VPSO Office/Garage 1,021 No Aleutian HA Aleutian HA Med. Notes 0 4 001 16 8 9 Earlier 1940s 1950s 1960s 1970s 1980s 1990s 2000‐11 Age of Housing Stock                                       144% 0% ‐44% Retrofitted BEES Certified Untouched Energy Efficient Housing Stock Community Profile: Atka Incorporation 2nd Class City Location Longitude ‐174.2006 Latitude 52.1961 ANCSA Region Aleut Corporation Borough/CA Aleutians East Borough School District Aleutian Region School District AEA Region Aleutians Alaska Native Name (definition)Taxes   Type (rate) Per‐Capita Revenue Atx ̂ax̂Bed (10%), Raw Fish (2%) 980$               Historical Setting / Cultural Resources Economy Climate Avg. Temp. Climate Zone Heating Deg. Da 38 7 9,054 Year Notes Community Plans Year 2006 2014 Local Contacts Phone Fax dirksjuliea@gmail.com 907‐839‐2233 907‐839‐2234 907‐839‐2229 907‐839‐2269 907‐839‐2237 907‐839‐2217 Demographics 2000 2010 2013 Population 92 61 Percent of Residents Employed 75% Median Age 36 36 Denali Commission Distressed Community No Avg. Household Size 33 Percent Alaska Native/American Indian (2010)95.08% Median Household Income $30,938 $60,000 Low and Moderate Income (LMI) Percent  (2014)60.0% Electric Utility Generation Sources Interties PCE? Yes Landfill Class 3 Permitted?Yes Location Water/Wastewater System City of Atka Homes Served System Volume Water Sewer Energy Audit? Notes Access Road Air Access Runway 4,500' x 100' Dock/Port Barge Access?Yes Ferry Service?No Notes None Atka Community Development Plan Atka Comprehensive Plan The island has been occupied by Unangas for at least 2,000  years. After the Japanese attacked Unalaska in 1942, the  U.S. gov't evacuated the area. Atka was burned to prevent  use by Japanese forces. The community was rebuilt by the  U.S. Navy, and residents were allowed to return. The St.  Nicholas Russian Orthodox Church is central to village life.  Sea lions and other sea mammals are  important to  subsistence lifestyle. Energy Priorities and Projects Atka is located on Atka Island, 1,200 air miles southwest from  Anchorage and 350 miles west of Unalaska. Local government, manufacturing, and professional‐business  services are the main employers. Natural Hazard Plan Atka Email  City of Atka Native Village of Atka atkaira@gci.net Atxam Corporation City of Atka Diesel/Hydroelectric No Continue wind reconnaissance; Maintain hydro & use  excess electricity for heating; Investigate solar powered  streetlights; Assess renewable energy options for fish plant  or for residential heat Piped 35 N/A Piped Yes No Publicly owned; Asphalt Yes Energy Profile: Atka Diesel Power System Power Production Utility Diesel (kWh/yr)108,883 Avg. Load (kW)59 Engine Make/Model Condition/Hrs Gen Capacity Wind (kWh/yr) Peak Load (kW)111 Unit 1 John Deere Fair/28,935 110 Hydro (kWh/yr)401,328 Efficiency (kWh/gal)10 Unit 2 John Deere Poor/27,565 110 Total (kWh/yr)510,211 Diesel Used (gals/yr)10,765 Unit 3 John Deere Good/16,727 37 Unit 4 Line Loss Heat Recovery? Upgrades Priority Projects Status RPSU Powerhouse Medium RPSU Distribution High Old Vlge Distr. Complete: 2011 Outage History/Known Issues Operators No. of Operators 12  Maintenance Planning (RPSU)Excellent Electric Rates ($/kWh) Cost per kWh Sold ($/kWh) Electric Sales No. of Customers kWh/year kWh/Customer Rate with PCE $0.25 Fuel Cost $0.14 Residential 30 163,699 5,457                   Residential Rate$0.73 Non‐fuel Cost $0.08 Community 2 52,928 26,464                 Commercial Rate Total Cost $0.22 Commercial 12 206,947 17,246                 Fuel Prices ($)Utility/Wholesale Retail Month/Year Utility Use 47,689 Diesel (1 gal)$5.29 $7.65 6‐13; 8‐14 Other Fuel? (1 gal) Gasoline (1 gal) Propane (100#) Wood (1 cord) Pellets Discounts? Alternative Energy Hydroelectric Wind Diesel Biomass Solar Geothermal Oil and Gas Coal Emerging Tech Heat Recovery Energy Efficiency Bulk Fuel Purchasing Deliveries/Year Gallons/Delivery Vendor(s) Tank Owner Fuel Type(s) Capacity Age/Condition By Barge 1 100,000+ Delta Western Alaska Native Store #1 Diesel; Gas 40,000; 10,000 By Air Atka Pride #2 Diesel 60,000 Cooperative Purchasing Agreements City of Atka #2 Diesel 40,000 Bulk Fuel Upgrade Priority Project Status Notes City of Atka 7.6% No #2 engine failure due to oil pressure Training/Certifications APPO, BF Bus., BFO, Elec. Util. Bus.,  Hydro, BFO, PPO, Clerk Potential Projects Status High Chuniisax Hydro Plant Operational as of 2012 Medium Atka Wind Power Project Recon/Feasibility Low Pending Medium Low Low Not Rated Medium (Diesel Generators) Atka Hydro Dispatched Excess Electrical Power Construction in 2015 High 1) EECBG 2) Streetlight Upgrade Complete None 35% 11% 44% 10% Residential Community Commercial Utility Use Electric Sales by Customer Type (kWh/year) 0 100 200 300 400 500 600 2010 2011 2012 2013 2014Electric Generation (MWh)Diesel Hydro Wind Energy Profile: Atka Housing Units Occupied Vacant % Owner‐Occup.Regional Housing Authority Weatherization Service Provider 24 23 92% Housing Need Overcrowded 1‐star Energy Use Average Home Average Avg. EUI  N/A Energy Rating Square Feet (kBTU/sf) Data Quality 5 star 1,018 73 Street Lighting Owner Number/Type Retrofitted? Year 12/Mer. Vapor Yes Non‐residential Building Inventory Building Name or Location Year Built Square Feet Audited? Retrofits Done? In ARIS? ARCS Bldg. 200 No Atxam Bldg. 2000 1,400 No City of Atka (office) 2014 1,920 Clinic 1979 1,980 No Post Office 2003 600 No Public Safety Bldg. 2010 600 No Shop/Garage 1999 2,400 No SRE Bldg. 4,250 Yes Water Treatment Plant 2013 900 No Yakov E. Netsvetov School 1982 8,130 No Aleutian HA Aleutian HA Med. Notes Replaced with LEDs  0 6 2 0 7 20 17 4 Earlier 1940s 1950s 1960s 1970s 1980s 1990s 2000‐11 Age of Housing Stock                                       50% 0% 50% Retrofitted BEES Certified Untouched Energy Efficient Housing Stock Community Profile: Cold Bay Incorporation 2nd Class City Location Longitude ‐162.7211 Latitude 55.1858 ANCSA Region Aleut Corporation Borough/CA Aleutians East Borough School District Aleutians East Borough School District  AEA Region Aleutians Alaska Native Name (definition)Taxes   Type (rate) Per‐Capita Revenue Udaamagax Bed (10%), Fuel Transfer ($.04/gal) 900$                  Historical Setting / Cultural Resources Economy Climate Avg. Temp. Climate Zone Heating Deg. Days 38.8 7 9,877 Year Notes Community Plans Year Cold Bay Economic Development Plan 2008 Local Contacts Phone Fax coldbayak@arctic.net 907‐532‐2401 907‐532‐2671 907‐277‐1440 907‐277‐1446 907‐532‐2407 907‐532‐2513 Demographics 2000 2010 2013 Population 88 108 Percent of Residents Employed 74% Median Age 34 45 Denali Commission Distressed Community No Avg. Household Size 33 Percent Alaska Native/American Indian (2010)12.04% Median Household Income $55,750 $54,688 Low and Moderate Income (LMI) Percent  (2014)24.7% Electric Utility Generation Sources Interties PCE? Yes Landfill Class 3 Permitted?No Location Water/Wastewater System Aleutians East Borough Homes Served System Volume Water Sewer Energy Audit? Notes Access Road Air Access Runway 2 runways: 10,180' x 150' & 6,235' x 150' Dock/Port Barge Access?Yes Ferry Service?Yes Notes Cold Bay is located in the Izembek National Wildlife Refuge at  the western end of the Alaska Peninsula. It lies 634 miles  southwest of Anchorage and 180 miles northeast of Unalaska. Trade/transportation/utilities, health services, and state  government are the main employers.  Natural Hazard Plan Yes City of Cold Bay Eastern Aleutian Tribes, Inc. Feasibility of District Heating Loop for gov't bldgs; Electric  utility wind energy project; Feasibility of Russel Creek Hydro;  Waste heat recovery project; Monitor tidal power  opportunities; Investigate city fuel farm Archaeological sites indicate the area around Cold Bay was  inhabited by a large Native population. During World War II,  Cold Bay was the site of Fort Randall. Cold Bay serves the  fishing industry and houses a number of federal offices.  Subsistence and recreational fishing and hunting are a part  of the local culture. Izembeck Lagoon offers the world's  largest eelgrass beds, providing feeding grounds for brant  during their migrations. Energy Priorities and Projects Publicly owned; Asphalt Yes Cold Bay Email  No G & K, Incorporated G & K, Incorporated Diesel No Piped 97 N/A Piped Energy Profile: Cold Bay Diesel Power System Power Production Utility Diesel (kWh/yr)2,660,684 Avg. Load (kW)295 Engine Make/Model Condition/Hrs Gen Capacity Wind (kWh/yr)0 Peak Load (kW)480 Unit 1 Caterpillar Good/87,188 875 Hydro (kWh/yr)0 Efficiency (kWh/gal)13 Unit 2 Caterpillar Good/75,653 850 Total (kWh/yr)2,660,684 Diesel Used (gals/yr)198,146 Unit 3 Caterpillar Good/81,925 875 Unit 4 Line Loss Heat Recovery? Upgrades Priority Projects Status RPSU Powerhouse Low RPSU Distribution Low Outage History/Known Issues Operators No. of Operators  Maintenance Planning (RPSU)Electric Rates ($/kWh) Cost per kWh Sold ($/kWh) Electric Sales No. of Customers kWh/year kWh/Customer Rate with PCE $0.20 Fuel Cost $0.45 Residential 38 177,955 4,683                   Residential Rate$0.71 Non‐fuel Cost $0.28 Community 4 119,179 29,795                 Commercial Rate Total Cost $0.73 Commercial 75 1,966,400 26,219                 Fuel Prices ($)Utility/Wholesale Retail Month/Year Utility Use 186,588 Diesel (1 gal)$5.19 $5.39 6‐13; 8‐14 Other Fuel? (1 gal) Gasoline (1 gal) Propane (100#) Wood (1 cord) Pellets Discounts? Alternative Energy Hydroelectric Wind Diesel Biomass Solar Pending Geothermal Oil and Gas Coal Emerging Tech Heat Recovery Energy Efficiency Bulk Fuel Purchasing Deliveries/Year Gallons/Delivery Vendor(s) Tank Owner Fuel Type(s) Capacity Age/Condition By Barge 3 to 4 Delta W./Crowley Frosty Fuels #2 Diesel; Jet A 110,000; 300,000 By Air G&K #2 Diesel 12,500 Cooperative Purchasing Agreements Bulk Fuel Upgrade Priority Project Status Notes G&K Inc. 7.9% No Training/Certifications Potential Projects Status Medium High Cold Bay Wind Energy Project Feasibility Low Low Low Low Not Rated Medium Cold Bay Waste Heat Recovery Project Feasibility High EECBG, AHFC‐C Complete 7% 5%80% 8% Residential Community Commercial Utility Use Electric Sales by Customer Type (kWh/year) 0 500 1000 1500 2000 2500 3000 3500 2010 2011 2012 2013 2014Electric Generation (MWh)Diesel Hydro Wind Energy Profile: Cold Bay Housing Units Occupied Vacant % Owner‐Occup.Regional Housing Authority Weatherization Service Provider 14 34 43% Housing Need Overcrowded 1‐star Energy Use Average Home Average Avg. EUI  N/A N/A Energy Rating Square Feet (kBTU/sf) Data Quality N/A N/A N/A Street Lighting Owner Number/Type Retrofitted? Year Non‐residential Building Inventory Building Name or Location Year Built Square Feet Audited? Retrofits Done? In ARIS? ARFF Bldg. 3,731 Yes City Housing Duplex 2,400 No Cold Bay RTH Yes Cold Bay School 1957‐1983 11,747 Yes Yes Living Quarters 4 1,820 Yes Living Quarters 5 1,820 Yes Living Quarters 6 1,820 Yes Living Quarters 9 1,820 Yes Maintenance Shop 5,400 Yes Old CFR Bldg. 5,560 Yes Sand Storage 4,200 Yes Warm Storage 2,624 Yes Aleutian HA Aleutian HA Low Notes 0 3 00 28 17 00 Earlier 1940s 1950s 1960s 1970s 1980s 1990s 2000‐11 Age of Housing Stock                                       0%0% 100% Retrofitted BEES Certified Untouched Energy Efficient Housing Stock Community Profile: False Pass Incorporation 2nd Class City Location Longitude ‐163.4088 Latitude 54.8539 ANCSA Region Aleut Corporation Borough/CA Aleutians East Borough School District Aleutians East Borough School District AEA Region Aleutians Alaska Native Name (definition)Taxes   Type (rate) Per‐Capita Revenue Isanak ("Gap, hole or tear") Sales (3%), Bed (6%), Raw Fish (2%) 3,020$               Historical Setting / Cultural Resources Economy Climate Avg. Temp. Climate Zone Heating Deg. Days 38.5 7 9,733 Year Notes Community Plans Year Local Contacts cityoffalsepass@ak.net Demographics 2000 2010 2013 Population 64 35 Percent of Residents Employed 78% Median Age 32 33 Denali Commission Distressed Community No Avg. Household Size 33 Percent Alaska Native/American Indian (2010)77.14% Median Household Income $49,375 $43,750 Low and Moderate Income (LMI) Percent  (2014)34.7% Electric Utility Generation Sources Interties PCE? Yes Landfill Class 3 Permitted?Yes Location Water/Wastewater System City of False Pass Homes Served System Volume Water Sewer Energy Audit? Notes Access Road Air Access Runway 2,150' x 60' Dock/Port Barge Access?Yes Ferry Service?Yes Notes None None The area was originally settled by a homesteader in  the early 1900s and grew with the establishment of a  cannery in 1917. Natives immigrated from Morzhovoi,  Sanak Island, and Ikatan when the cannery was built.  The community is primarily Unangan. Fishing, fish  processing, and subsistence activities are mainstays of  the lifestyle. Energy Priorities and Projects False Pass is located on the eastern shore of Unimak Island on  a strait connecting the Pacific Gulf of Alaska to the Bering  Sea. It is 646 air miles southwest of Anchorage. Local government, manufacturing, and financial activities are  the main employers.  Natural Hazard Plan False Pass Email  City of False Pass Eastern Aleutian Tribes, Inc. Isanotski Corporation City of False Pass Diesel No Address high line loss and diesel efficiency; Assess  feasibility of  expanding heat recovery to school; finish  wind feasibility study; hydro feasibility for run of river  sites Piped 60 10,000‐50,000  gpd (water)Piped Yes No Publicly owned; Gravel Yes Energy Profile: False Pass Diesel Power System Power Production Utility Diesel (kWh/yr)778,559 Avg. Load (kW)69 Engine Make/Model Condition/Hrs Gen Capacity Wind (kWh/yr)0 Peak Load (kW)190 Unit 1 John Deere Fair/4 75 Hydro (kWh/yr)0 Efficiency (kWh/gal)13 Unit 2 John Deere Fair/11,483 125 Total (kWh/yr)778,559 Diesel Used (gals/yr)60,967 Unit 3 John Deere Fair/17,789 175 Unit 4 Line Loss Heat Recovery? Upgrades Priority Projects Status RPSU Powerhouse Med. RPSU Distribution Med. Outage History/Known Issues Operators No. of Operators 5  Maintenance Planning (RPSU)Acceptable Electric Rates ($/kWh) Cost per kWh Sold ($/kWh) Electric Sales No. of Customers kWh/year kWh/Customer Rate with PCE $0.14 Fuel Cost $0.32 Residential 27 124,174 4,599                   Residential Rate$0.42 Non‐fuel Cost $0.12 Community 11 66,925 6,084                   Commercial Rate Total Cost $0.45 Commercial 19 473,264 24,909                 Fuel Prices ($)Utility/Wholesale Retail Month/Year Utility Use 43,433 Diesel (1 gal)$3.52 $4.21 6‐13; 8‐14 Other Fuel? (1 gal) Gasoline (1 gal) Propane (100#)$286.43 8‐14 Wood (1 cord) Pellets Discounts? Alternative Energy Hydroelectric Wind Diesel Biomass Solar Pending Geothermal Oil and Gas Coal Emerging Tech Heat Recovery Energy Efficiency Bulk Fuel Purchasing Deliveries/Year Gallons/Delivery Vendor(s) Tank Owner Fuel Type(s) Capacity Age/Condition By Barge 1 City of False Pass #2 Diesel 65,000 11 yrs. By Air Peter Pan Seafood #1 Heat; #2 Diesel 27,000; 300,000 Cooperative Purchasing Agreements Bulk Fuel Upgrade Priority Project Status Notes City of False Pass 9.1% Yes; City Shop Training/Certifications BF Manager, Clerk, BF Book, BFO Low 2.4 kW wind turbine; Utility wind project Pilot project; feasibility study Low Potential Projects Status High Low Not Rated False Pass Hydrokinetic High Waste Heat Recovery System to City Shop Operational/Ageing High EECBG, ACEA, AHFC‐C Complete on hold Low Low 18% 9% 67% 6% Residential Community Commercial Utility Use Electric Sales by Customer Type (kWh/year) 0 100 200 300 400 500 600 700 800 900 2010 2011 2012 2013 2014Electric Generation (MWh)Diesel Hydro Wind Energy Profile: False Pass Housing Units Occupied Vacant % Owner‐Occup.Regional Housing Authority Weatherization Service Provider 8 45 38% Housing Need Overcrowded 1‐star Energy Use Average Home Average Avg. EUI  N/A N/A Energy Rating Square Feet (kBTU/sf) Data Quality N/A N/A N/A Street Lighting Owner Number/Type Retrofitted? Year Non‐residential Building Inventory Building Name or Location Year Built Square Feet Audited? Retrofits Done? In ARIS? Bering Pacific Seafoods Bunkhouse 6,800 No Bering Pacific Seafoods Multipurpose 4,000 No Bering Pacific Seafoods Plant 13,200 No City Office/Community Center 1 1986 2,448 Yes Yes; VEEP Yes City Office/Community Center 2 2,432 Yes; VEEP Yes City Shop 1995 6,000 Yes; VEEP Yes Clinic/Medical Center 1998 1,280 Yes; VEEP Yes Clinic/Public Safety Office 4,629 Yes False Pass City Hall 1985 No False Pass Public Safety Bldg. 1 1996 4,591 Yes False Pass Public Safety Bldg. 2 2002 2,994 Yes False Pass Public Safety Bldg. 3 2002 4,629 Yes False Pass School 1 1986 9,584 Yes; VEEP Yes False Pass School 2 1986 10,939 Yes; VEEP Yes Grocery Store Yes; VEEP No Isanotski Office/Triplex Yes; VEEP No Library/Post Office Yes; VEEP No Liquor Store Yes; VEEP No Old Generator Bldg.Yes; VEEP No SRE Bldg. 1,104 Yes Tribal Office/Warehouse Yes; VEEP No Water Treatment Plant Yes; VEEP No Aleutian HA Aleutian HA Low Notes 7 5 0 4 6 17 14 2 Earlier 1940s 1950s 1960s 1970s 1980s 1990s 2000‐11 Age of Housing Stock                                       50%0% 50% Retrofitted BEES Certified Untouched Energy Efficient Housing Stock Community Profile: King Cove Incorporation 1st Class City Location Longitude ‐162.3103 Latitude 55.0617 ANCSA Region Aleut Corporation Borough/CA Aleutians East Borough School District Aleutians East Borough School District AEA Region Aleutians Alaska Native Name (definition)Taxes   Type (rate) Per‐Capita Revenue Agdaaĝux̂Sales (4%), Raw Fish (2%), Fisheries ($100k)1,750$               Historical Setting / Cultural Resources Economy Climate Avg Temp Climate Zone Heat. Deg. Days 38.3 7 9,733 Year Notes Community Plans Year 2006 2003 Local Contacts Phone Fax cityclerk@kingcoveak.org 907‐497‐2340 907‐497‐2594 907‐497‐2648 907‐497‐2803 907‐497‐2312 907‐497‐2444 Demographics 2000 2010 2013 Population 792 938 Percent of Residents Employed 60% Median Age 35 42 Denali Commission Distressed Community No Avg. Household Size 33 Percent Alaska Native/American Indian (2010)38.38% Median Household Income $45,893 $62,917 Low and Moderate Income (LMI) Percent  (2014)46.5% Electric Utility Generation Sources Interties PCE? Yes Landfill Class 3 Permitted?Yes Location Water/Wastewater SystemAE Borough/City of KC Homes Served System Volume Water 972 Sewer Energy Audit? Notes Access Road Air Access Runway 3,500' x 115' Dock/Port Barge Access?Yes Ferry Service?Yes Notes None Comprehensive Community Plan City of King Cove Waterfront Util. Plan Identify funding to complete Waterfall Creek  hydro; Complete wind feasibility study; Secure a  Power Purchase Agreement with Peter Pan King Cove was founded in 1911 when Pacific  American Fisheries built a salmon cannery. Early  settlers were Unangan, Scandinavian, and other  European fishermen. King Cove remains tied to  fishing and fish processing. Scandinavians have  historically influenced the cultural, economic,  and social structures. King Cove is a mixed non‐ Native and Unangan community. Energy Priorities and Projects King Cove is located on the south side of the Alaska  Peninsula, on a sand spit fronting Deer Passage and Deer  Island. It is 18 miles southeast of Cold Bay and 625 miles  southwest of Anchorage Local government, trade, transportation/utilities, and health  services are main employers. Fishing & processing is a major  employer. Natural Hazard Plan No Piped 100,001 ‐  500,000 gpd  (water) Piped Yes Email  City of King Cove The King Cove Corp. City of King Cove Diesel, Hydropower Agdaagux Tribe ettakuzakin@yahoo.com No Publicly owned; gravel Yes King Cove Energy Profile: King Cove Diesel Power System Power Production Utility Diesel (kWh/yr)2,167,190 Avg. Load (kW)486 Engine Make/Model Condition/Hrs Gen Capacity Wind (kWh/yr)0 Peak Load (kW)904 Unit 1 Caterpillar Good/9,343 1050 Hydro (kWh/yr)2,346,281 Efficiency (kWh/gal)14 Unit 2 Caterpillar Good/4,529 650 Total (kWh/yr)4,513,471 Diesel Used (gals/yr)153,210 Unit 3 Caterpillar Good/1,450 500 Unit 4 Caterpillar Good/8,367 500 Line Loss Heat Recovery? Upgrades Priority Projects Status RPSU Powerhouse Low RPSU Distribution Med. Outage History/Known Issues Operators No. of Operators 12  Maintenance Planning (RPSU)Electric Rates ($/kWh) Cost per kWh Sold ($/kWh) Electric Sales No. of Customers kWh/year kWh/Customer Rate with PCE $0.23 Fuel Cost $0.15 Residential 193 1,078,081 5,586                   Residential Rate $0.30 Non‐fuel Cost $0.01 Community 32 954,306 29,822                 Commercial Rate Total Cost $0.16 Commercial 203 1,665,230 8,203                   Fuel Prices ($)Utility/Wholesale Retail Month/Year Utility Use 66,285 Diesel (1 gal)$3.75 $4.29 6‐13; 8‐14 Other Fuel? (1 gal) Gasoline (1 gal) Propane (100#) Wood (1 cord) Pellets Discounts? Alternative Energy Hydroelectric Wind Diesel Biomass Solar Geothermal Oil and Gas Coal Emerging Tech Heat Recovery Energy Efficiency Bulk Fuel Purchasing Deliveries/Year Gallons/Delivery Vendor(s) Tank Owner Fuel Type(s) Capacity Age/Condition By Barge 3 to 4 Delta W.; Crowley City of King Cove #2 Diesel 159,500 Unknown By Air Peter Pan #Diesel/Gas. 1,000,000 15 yrs.Cooperative Purchasing Agreements Bulk Fuel Upgrade Priority Project Status Notes Not Rated Low Diesel Gen Heat Recovery; Hydro Electric Boiler Operational High EECBG, AHFC‐C, VEEP, Streetlight Upgrade Complete Low Low Pending Low High Ram Creek Wind Met Tower Installed Low Potential Projects Status High Delta Creek, 800 kW; Waterfall Creek, 375 kW Operational; Construction City of King Cove 16.6% Yes, community buildings No RPSU data. Training/Certifications APPO, BF Book, BFO, Hydro, PPO,  Clerk 29% 25%44% 2% Residential Community Commercial Utility Use Electric Sales by Customer Type (kWh/year) 0 500 1000 1500 2000 2500 3000 3500 2010 2011 2012 2013 2014Electric Generation (MWh)Diesel Hydro Wind Energy Profile: King Cove Housing Units Occupied Vacant % Owner‐Occup.Regional Housing Authority Weatherization Service Provider 118 16 52% Housing Need Overcrowded 1‐star Energy Use Average Home Average Avg. EUI  2.5% 13.2%Energy Rating Square Feet (kBTU/sf) Data Quality 4 star 864 106 Street Lighting Owner Number/Type Retrofitted? Year City 68/HPS Yes 2012 Non‐residential Building Inventory Building Name or Location Year Built Square Feet Audited? Retrofits Done? In ARIS? Bible Chapel Church 2,365 Yes; VEEP No King Cove Corp. Hotel 8,768 Yes; VEEP No King Cove K‐12 School 2 2007 43,843 Yes King Cove K‐12 School 1 2007 43,308 Yes Yes Public Safety Bldg. 3,180 No SRE Bldg. (Heated) 2,200 Yes Tribal Office 2,172 Yes; VEEP No Med. Notes Replaced with LED; Est. savings of 40,506 kWh Aleutian HA Aleutian HA 0 8 7 6 46 41 24 6 Earlier 1940s 1950s 1960s 1970s 1980s 1990s 2000‐11 Age of Housing Stock                                       42% 4% 54% Retrofitted BEES Certified Untouched Energy Efficient Housing Stock Community Profile: Nelson Lagoon Incorporation Unincorporated Location Longitude ‐161.2028 Latitude 56.0019 ANCSA Region Aleut Corporation Borough/CA Aleutians East Borough School District Aleutians East Borough School District AEA Region Aleutians Alaska Native Name (definition)Taxes   Type (rate) Per‐Capita Revenue Niilsanam Alĝuudaa N/A Historical Setting / Cultural Resources Economy Climate Avg. Temp Climate Zone Heating Deg. Days 32 7 8,865 Year Notes Community Plans Year Local Contacts Phone Fax jgunde1125@aol.com 907‐989‐2204 907‐989‐2233 907‐277‐1440 907‐277‐1446 907‐989‐2204 907‐989‐2233 Demographics 2000 2010 2013 Population 83 52 Percent of Residents Employed 65% Median Age 34 41 Denali Commission Distressed Community No Avg. Household Size 33Percent Alaska Native/American Indian (2010)75% Median Household Income $43,750 $52,708 Low and Moderate Income (LMI) Percent  (2014)48.7% Electric Utility Generation Sources Interties PCE? Yes Landfill Class 3 Permitted Yes Location Water/Wastewater System Aleutians East Borough Homes Served System Volume Water Sewer Energy Audit? Notes Access Road Air Access Runway 4,003' x 75' Dock/Port Barge Access?Yes Ferry Service?No Notes None Strategic Economic and Community  Development Plan 2001Biomass feasibility; Install met tower for wind study;  Interest in solar; Monitor tidal energy opps; Look into  AVTEC utility operator training; Overhaul generator &  upgrade distribution system Nelson Lagoon has been used historically as an  Unangan summer fish camp. The resources of the  lagoon and nearby Bear River are excellent. In 1965 a  school was built, and the community began to be  occupied year‐round. The culture is focused on  commercial fishing and subsistence activities. There is a  strong community pride and loyalty among the  residentsEnergy Priorities and Projects Nelson Lagoon is located on the northern coast of the Alaska  Peninsula, on a narrow sand spit that separates the lagoon  from the Bering Sea. It is 580 miles southwest of Anchorage. Local government, health services, and utilities are main  employers. Fishing is a major part of the economy. Natural Hazard Plan Yes NV of Nelson Lagoon Eastern Aleutian Tribes, Inc. Publicly owned; Gravel Yes Nelson Lagoon Email  No Nelson Lagoon Corporation Nelson Lagoon Electrical Cooperative Diesel No Piped 103 10,000 ‐ 50,000  gpd (water)Piped Energy Profile: Nelson Lagoon Diesel Power System Power Production Utility Diesel (kWh/yr)343,990 Avg. Load (kW)46 Engine Make/Model Condition/Hrs Gen Capacity Wind (kWh/yr)0 Peak Load (kW)96 Unit 1 Perkins Condemned 75 Hydro (kWh/yr)0 Efficiency (kWh/gal)9 Unit 2 John Deere Fair/29,221 100 Total (kWh/yr)343,990 Diesel Used (gals/yr)39,158 Unit 3 John Deere Fair/25,452 150 Unit 4 Line Loss Heat Recovery? Upgrades Priority Projects Status RPSU Powerhouse High RPSU Distribution High Outage History/Known Issues Operators No. of Operators 5  Maintenance Planning (RPSU)Acceptable Electric Rates ($/kWh) Cost per kWh Sold ($/kWh) Electric Sales No. of Customers kWh/year kWh/Customer Rate with PCE $0.19 Fuel Cost $0.66 Residential 32 124,562 3,893                   Residential Rate$0.84 Non‐fuel Cost $0.69 Community 5 33,735 6,747                   Commercial Rate Total Cost $1.36 Commercial 21 132,482 6,309                   Fuel Prices ($)Utility/Wholesale Retail Month/Year Utility Use 10,661 Diesel (1 gal)$4.33 $6.25 6‐13; 8‐14 Other Fuel? (1 gal) Gasoline (1 gal) Propane (100#) Wood (1 cord) Pellets Discounts? Alternative Energy Hydroelectric Wind Diesel Biomass Solar Pending Geothermal Oil and Gas Coal Emerging Tech Heat Recovery Energy Efficiency Bulk Fuel Purchasing Deliveries/Year Gallons/Delivery Vendor(s) Tank Owner Fuel Type(s) Capacity Age/Condition By Barge 1 Crowley Nelson Lagoon Entps Diesel #2; Heat #1 54,000; 81,000 11 yrs. By Air Nelson Lagoon Entps AV Gas; Gasoline 54,000; 54,000 11 yrs.Cooperative Purchasing Agreements Bulk Fuel Upgrade Priority Project Status Notes Not Rated Medium High AHFC‐R Complete Low Low Low Low Low 2.4 kW wind turbine Pilot project Nelson Lagoon Electrical Coop 12.4% No Unit 1 condemned; Meters need to be replaced. Training/Certifications BFO, BF Book, Clerk Potential Projects Status Low 41% 11% 44% 4% Residential Community Commercial Utility Use Electric Sales by Customer Type (kWh/year) 0 50 100 150 200 250 300 350 400 450 2010 2011 2012 2013 2014Electric Generation (MWh)Diesel Hydro Wind Energy Profile: Nelson Lagoon Housing Units Occupied Vacant % Owner‐Occup.Regional Housing Authority Weatherization Service Provider 14 12 57% Housing Need Overcrowded 1‐star Energy Use Average Home Average Avg. EUI  21.4% N/A Energy Rating Square Feet (kBTU/sf) Data Quality N/A N/A N/A Street Lighting Owner Number/Type Retrofitted? Year Non‐residential Building Inventory Building Name or Location Year Built Square Feet Audited? Retrofits Done? In ARIS? Community Bldg.No Council Office 660 No Health Clinic No Nelson Lagoon School 5,776 No Nelson Lagoon Storage Co. 6,500 No SRE Bldg. 1,104 Yes Village Public Safety Office No Med. Notes Aleutian HA Aleutian HA 00 5 0 5 12 4 2 Earlier 1940s 1950s 1960s 1970s 1980s 1990s 2000‐11 Age of Housing Stock                                       57%0% 43% Retrofitted BEES Certified Untouched Energy Efficient Housing Stock Community Profile: Nikolski Incorporation Unincorporated Location Longitude ‐168.8678 Latitude 52.9381 ANCSA Region Aleut Corporation Borough/CA Aleutians West Census Area School District Aleutian Region School District AEA Region Aleutians Alaska Native Name (definition)Taxes   Type (rate) Per‐Capita Revenue Chalukax̂N/A Historical Setting / Cultural Resources Economy Climate Avg. Temp Climate Zone Heating Deg. Days 10.8 7 9,555 Year Notes Community Plans Year Local Contacts Phone Fax nvnikolski@hotmail.com 907‐576‐2225 907‐576‐2205 Chaluka Corporation 907‐576‐2215 Demographics 2000 2010 2013 Population 39 18 Percent of Residents Employed 62% Median Age 40 57 Denali Commission Distressed Community No Avg. Household Size 32 Percent Alaska Native/American Indian (2010)94.44% Median Household Income $38,750 $24,375 Low and Moderate Income (LMI) Percent  (2014)77.6% Electric Utility Generation Sources Interties PCE? Yes Landfill Class Permitted? Location Water/Wastewater System Homes Served System Volume Water Sewer Energy Audit? Notes Access Road Air Access Runway 3,512' x 135' Dock/Port Barge Access?No Ferry Service?No Notes No Native Village of Nikolski Nikolski is located on Nikolski Bay, off the southwest end of  Umnak Island, one of the Fox Islands. It lies 116 air miles west  of Unalaska and 900 air miles from Anchorage. Local government, health services, and leisure/hospitality are  main employers.  Natural Hazard Plan Nikolski Community and Economic  Development Plan 2006 Nikolski is reputed by some to be the oldest continuously‐ occupied community in the world. Archaeological evidence  dates back 8,500 years. In 1834, it was the site of sea otter  hunting. In 1942, when the Japanese attacked Unalaska and  seized Attu and Kiska, residents were evacuated. Locals  returned in 1944. Subsistence activities, sheep and cattle  raising, and fishing‐related employment sustain the  community. Energy Priorities and Projects Privately Owned; Gravel No Email  No Umnak Power Company Diesel, Wind Piped Piped Energy Profile: Nikolski Diesel Power System Power Production Utility Diesel (kWh/yr)207,693 Avg. Load (kW)24 Engine Make/Model Condition/Hrs Gen Capacity Wind (kWh/yr)0 Peak Load (kW)55 Unit 1 John Deere Fair/43,463 71 Hydro (kWh/yr)0 Efficiency (kWh/gal)10 Unit 2 John Deere Fair/11,091 71 Total (kWh/yr)207,693 Diesel Used (gals/yr)20,940 Unit 3 John Deere Fair/7,830 54 Unit 4 Line Loss Heat Recovery? Upgrades Priority Projects Status RPSU Powerhouse Med. RPSU Distribution Low Outage History/Known Issues Operators No. of Operators 5 PPO, Clerk  Maintenance Planning (RPSU)Unacceptable Electric Rates ($/kWh) Cost per kWh Sold ($/kWh) Electric Sales No. of Customers kWh/year kWh/Customer Rate with PCE $0.14 Fuel Cost $0.71 Residential 14 52,727 3,766                   Residential Rate$0.60 Non‐fuel Cost $0.24 Community 5 33,056 6,611                   Commercial Rate Total Cost $0.95 Commercial 8 92,206 11,526                 Fuel Prices ($)Utility/Wholesale Retail Month/Year Utility Use 17,016 Diesel (1 gal)$6.00 $7.00 6‐13; 8‐13 Other Fuel? (1 gal) Gasoline (1 gal) Propane (100#) Wood (1 cord) Pellets Discounts? Alternative Energy Hydroelectric Wind Diesel Biomass Solar Pending Geothermal Oil and Gas Coal Emerging Tech Heat Recovery Energy Efficiency Bulk Fuel Purchasing Deliveries/Year Gallons/Delivery Vendor(s) Tank Owner Fuel Type(s) Capacity Age/Condition By Barge 1 Nikolski Tribal Counc #2 Diesel 54,000 Good By Air Nikolski Tribal Counc Gasoline 5,000 Good Cooperative Purchasing Agreements Bulk Fuel Upgrade Priority Project Status Notes Not Rated Low Heat Recovery to utility office Operational High AHFC‐R Complete Barge delivery in early fall. Low Low Low Low Nikolski Wind Project, 65 kW Installed; Not connected to grid Low Potential Projects Status Low Umnak Power Company 6.1% Yes; Utility Office Training/Certifications 27% 17%47% 9% Residential Community Commercial Utility Use Electric Sales by Customer Type (kWh/year) 0 50 100 150 200 250 300 2010 2011 2012 2013 2014Electric Generation (MWh)Diesel Hydro Wind Energy Profile: Nikolski Housing Units Occupied Vacant % Owner‐Occup.Regional Housing Authority Weatherization Service Provider 27 4 30% Housing Need Overcrowded 1‐star Energy Use Average Home Average Avg. EUI  N/A N/A Energy Rating Square Feet (kBTU/sf) Data Quality N/A N/A N/A Street Lighting Owner Number/Type Retrofitted? Year Non‐residential Building Inventory Building Name or Location Year Built Square Feet Audited? Retrofits Done? In ARIS? Nikolski School Yes No Teacher Housing Yes No Tribal Office/Community Hall 2,400 Yes No Med. Notes Aleutian HA Aleutian HA 00004 27 00 Earlier 1940s 1950s 1960s 1970s 1980s 1990s 2000‐11 Age of Housing Stock                                       48%0% 52% Retrofitted BEES Certified Untouched Energy Efficient Housing Stock Community Profile: Sand Point Incorporation 1st Class City Location Longitude ‐160.4972 Latitude 55.3397 ANCSA Region Aleut Corporation Borough/CA Aleutians East Borough School District Aleutians East Borough School District AEA Region Aleutians Alaska Native Name (definition)Taxes   Type (rate) Per‐Capita Revenue Qagun Tayagungin Sales (4%), Bed (7%), Raw Fish (2%) 1,640$               Historical Setting / Cultural Resources Economy Climate Avg. Temp Climate Zone Heating Deg. Days 41.1 7 8,865 Year Notes Community Plans Year 2003 Local Contacts Phone Fax sptcity@arctic.net 907‐383‐2696 907‐383‐2698 907‐383‐5616 907‐383‐5814 907‐383‐3525 907‐383‐5356 Demographics 2000 2010 2013 Population 952 976 Percent of Residents Employed 58% Median Age 37 41 Denali Commission Distressed Community No Avg. Household Size 33 Percent Alaska Native/American Indian (2010)39.04% Median Household Income $55,417 $70,500 Low and Moderate Income (LMI) Percent  (2014)41.7% Electric Utility Generation Sources Interties PCE? Yes Landfill Class 3 Permitted?Yes Location Water/Wastewater System City of Sand Point Homes Served System Volume Water 962 Sewer Energy Audit? Notes Access Road Air Access Runway 5,213' x 150' Dock/Port Barge Access?Yes Ferry Service?Yes Notes City of Sand Point Qagan Tayagungin Tribe qttadmin@arctic.net Sand Point is located on Humboldt Harbor on Popof Island, off  the Alaska Peninsula, 570 air miles from Anchorage. Local government, manufacturing, and trade are the main  employers. Fishing is a major part of the economy. Natural Hazard Plan None Harbor Land Use Plan for Sand Point City of Sand Point Comprehensive Community  Development Plan 2004Expand wind capacity, integration into grid; Biomass  feasibility; Monitor tidal power opportunities; Install electric  boiler in school to harness excess wind energy and improve  performance; Assess feasibility of district heating with waste  heat Sand Point was founded in 1898 by a San Francisco fishing  company as a trading post and fishing station. Aleuts from  surrounding villages and Scandinavian fishermen were the  first residents. Sand Point served as a center for gold mining  in the early 1900s, but fish processing became the dominant  activity in the 1930s. Today, it is home to the largest fishing  fleet in the Aleutian Chain. There is a large transient  population for fishing and cannery work.  Energy Priorities and Projects Publicly Owned; Asphalt Yes Sand Point Email  No Shumagin Corporation TDX Sand Point Diesel, Wind No Piped 100K – 500K gpd  (water); 100K –  500K gpd (ww)Piped Yes Energy Profile: Sand Point Diesel Power System Power Production Utility Diesel (kWh/yr)3,058,309 Avg. Load (kW)440 Engine Make/Model Condition/Hrs Gen Capacity Wind (kWh/yr)861,495 Peak Load (kW)992 Unit 1 Caterpillar Fair/41,053 900 Hydro (kWh/yr)0 Efficiency (kWh/gal)14 Unit 2 Caterpillar Fair/65,437 875 Total (kWh/yr)3,919,804 Diesel Used (gals/yr)219,998 Unit 3 Caterpillar Fair/1,948 455 Unit 4 Caterpillar Fair/26,593 650 Line Loss Heat Recovery? Upgrades Priority Projects Status RPSU Powerhouse High RPSU Distribution High Outage History/Known Issues Operators No. of Operators  Maintenance Planning (RPSU)Good Electric Rates ($/kWh) Cost per kWh Sold ($/kWh) Electric Sales No. of Customers kWh/year kWh/Customer Rate with PCE $0.20 Fuel Cost $0.28 Residential 289 1,392,193 4,817                   Residential Rate$0.50 Non‐fuel Cost $0.12 Community 27 467,563 17,317                 Commercial Rate Total Cost $0.41 Commercial 93 1,756,660 18,889                 Fuel Prices ($)Utility/Whlsale Retail Month/Year Utility Use 90,560 Diesel (1 gal)$4.55 $5.15 6‐13; 8‐14 Other Fuel? (1 gal) Gasoline (1 gal) Propane (100#)$187.14 8‐14 Wood (1 cord) Pellets Discounts? Alternative Energy Hydroelectric Wind Diesel Biomass Solar Geothermal Oil and Gas Coal Emerging Tech Heat Recovery Energy Efficiency Bulk Fuel Purchasing Deliveries/Year Gallons/Delivery Vendor(s) Tank Owner Fuel Type(s) Capacity Age/Condition By Barge Trident Seafood #2 Diesel 800,000 By Air SPG/TDX #2 Diesel 41,000 Cooperative Purchasing Agreements Bulk Fuel Upgrade Priority Project Status Notes Not Rated Low Heat recovery to TDX building Operating High EECBG, AHFC‐C, AHFC‐R Low Low Pending Low High Sand Point Wind Operating Low Potential Projects Status Low TDX Corp. 5.4% Yes; TDX Bldg. Training/Certifications 38% 13%47% 2% Residential Community Commercial Utility Use Electric Sales by Customer Type (kWh/year) 0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 2010 2011 2012 2013 2014Electric Generation (MWh)Diesel Hydro Wind Energy Profile: Sand Point Housing Units Occupied Vacant % Owner‐Occup.Regional Housing Authority Weatherization Service Provider 164 67 53% Housing Need Overcrowded 1‐star Energy Use Average Home Average Avg. EUI  3.7% 8.5%Energy Rating Square Feet (kBTU/sf) Data Quality 3 star 1,466 122 Street Lighting Owner Number/Type Retrofitted? Year 95/ Incandescent Yes 2011 Non‐residential Building Inventory Building Name or Location Year Built Square Feet Audited? Retrofits Done? In ARIS? AC Store AEB Office Building Airport Terminal No Aleutians East Borough District Office 1 1996 3,739 Yes Aleutians East Borough District Office 2 1996 4,600 Yes ARFF (Aircraft Rescue & Firefighting) Bldg. 5,369 Yes Bozo Burgers City Bldg.No City Shop Community Recreation Center No Harbor Café Recycling Center Sand Point Office 2000 2,700 Yes Sand Point School 1983 49,293 Yes Yes Sand Point Tavern Sand Storage (Heated) 3,378 Yes Teen Center Toys Plus Trident Store/Facility Unga Office Water Treatment Plant High Notes Replaced with LEDs Aleutian HA Aleutian HA 2 88 28 82 83 19 19 Earlier 1940s 1950s 1960s 1970s 1980s 1990s 2000‐11 Age of Housing Stock                                       29%1% 70% Retrofitted BEES Certified Untouched Energy Efficient Housing Stock Community Profile: Saint George Incorporation 2nd Class City Location Longitude ‐169.5417 Latitude 56.6000 ANCSA Region Aleut Corporation Borough/CA Aleutians West Census Area School District Pribilof School District AEA Region Aleutians Alaska Native Name (definition)Taxes   Type (rate) Per‐Capita Revenue Anĝaaxchalux̂Sales (3%), Raw Fish (3%) N/A Historical Setting / Cultural Resources Economy Climate Avg. Temp Climate Zone Heating Deg. Days 36.3 7 10,242 Year Notes Community Plans Year 2007 2006 Local Contacts Phone Fax pat714swet@yahoo.com 907‐859‐2236 907‐859‐2242 907‐859‐2205 907‐859‐2242 907‐272‐9886 907‐272‐9855 Demographics 2000 2010 2013 Population 152 102 Percent of Residents Employed 71% Median Age 33 39 Denali Commission Distressed Community No Avg. Household Size 33Percent Alaska Native/American Indian (2010)88.24% Median Household Income $57,083 $44,792 Low and Moderate Income (LMI) Percent  (2014)36.4% Electric Utility Generation Sources Interties PCE? Yes Landfill Class 3 Permitted?Yes Location Water/Wastewater System City of St. George Homes Served System Volume Water Sewer Energy Audit? Notes Access Road Air Access Runway 4,982' x 150' Dock/Port Barge Access?Yes Ferry Service?No Notes St. George is located on the northeast shore of St. George  Island, the southern‐most of the four Pribilof Islands. It lies 47  miles south of St. Paul Island, 750 air miles west of Anchorage,  and 250 miles northwest of Unalaska. Local government provides roughly 75% of the employment  for St. George. Fishing is a major part of the economy. Natural Hazard Plan None Yes Saint George Island chris_merculief@yahoo.com St. George Community Strategic Plan St. George Traditional Council Strategic Plan Install 95 kW wind turbine, integrate into existing grid; Solar  feasibility study; Complete AEA Rural Power System Upgrade  and heat recovery; Lower bulk fuel costs by partnering with  other buyers; Harbor reconstruction and dredging For centuries, Aleuts traveled to St. George for hunting and  fishing. The Russian American Company enslaved Aleut  hunters from Siberia, Unalaska, and Atka and relocated them  to St. George and St. Paul to harvest fur seal. During World  War II, the Pribilof Aleuts were confined at Funter Bay. In  1979, Aleut Islanders received $8.5M in compensation for  this treatment. Residents are working to develop fisheries  and tourism.  Energy Priorities and Projects Publicly Owned; Gravel Yes Saint George Email  City of St. George No St. George Tanaq Corp City of St. George Diesel No Piped 200 N/A Piped Energy Profile: Saint George Diesel Power System Power Production Utility Diesel (kWh/yr)693,419 Avg. Load (kW)73 Engine Make/Model Condition/Hrs Gen Capacity Wind (kWh/yr)0 Peak Load (kW)139 Unit 1 Detroit Diesel Fair/77,345 350 Hydro (kWh/yr)0 Efficiency (kWh/gal)13 Unit 2 Caterpillar Fair/10,993 175 Total (kWh/yr)693,419 Diesel Used (gals/yr)51,429 Unit 3 Caterpillar Poor/25,000 175 Unit 4 Detroit Diesel Poor 480 Line Loss Heat Recovery? Upgrades Priority Projects Status RPSU Powerhouse In Progress RPSU Distribution Low Outage History/Known Issues Operators No. of Operators 5 BFO, PPO, Clerk  Maintenance Planning (RPSU)Acceptable Electric Rates ($/kWh) Cost per kWh Sold ($/kWh) Electric Sales No. of Customers kWh/year kWh/Customer Rate with PCE $0.32 Fuel Cost $0.70 Residential 39 153,400 3,933                   Residential Rate$1.00 Non‐fuel Cost $0.12 Community 7 106,227 15,175                 Commercial Rate Total Cost $0.82 Commercial 29 274,068 9,451                   Fuel Prices ($)Utility/Wholesale Retail Month/Year Utility Use 25,804 Diesel (1 gal)$7.43 $7.74 6‐13; 8‐14 Other Fuel? (1 gal) Gasoline (1 gal) Propane (100#)$302.62 8‐14 Wood (1 cord) Pellets Discounts? Alternative Energy Hydroelectric Wind Diesel Biomass Solar Geothermal Oil and Gas Coal Emerging Tech Heat Recovery Energy Efficiency Bulk Fuel Purchasing Deliveries/Year Gallons/Delivery Vendor(s) Tank Owner Fuel Type(s) Capacity Age/Condition By Barge 2 City of Saint George #2 Diesel 1,066,200 Unknown By Air Cooperative Purchasing Agreements Bulk Fuel Upgrade Priority Project Status Notes Not Rated Low High EECBG Complete Barge delivery in Spring & Fall. Low Low Pending Low High St. George Wind Farm Construction (near operation) Low Potential Projects Status Low City of Saint George 19.3% No; City Shop (Defective) No coolant. Engine hours in question. Training/Certifications 27% 19%49% 5% Residential Community Commercial Utility Use Electric Sales by Customer Type (kWh/year) 0 100 200 300 400 500 600 700 800 900 2010 2011 2012 2013 2014Electric Generation (MWh)Diesel Hydro Wind Energy Profile: Saint George Housing Units Occupied Vacant % Owner‐Occup.Regional Housing Authority Weatherization Service Provider 53 23 72% Housing Need Overcrowded 1‐star Energy Use Average Home Average Avg. EUI  5.7% N/A Energy Rating Square Feet (kBTU/sf) Data Quality N/A N/A N/A Street Lighting Owner Number/Type Retrofitted? Year Non‐residential Building Inventory Building Name or Location Year Built Square Feet Audited? Retrofits Done? In ARIS? Carpentry Shop No City Office No Fish Plant No Health Clinic 3,675 No Power Plant 6,000 No Public Works Bldg. 1,200 No Recreation Hall/Admin Office 4,800 No SRE Bldg. 1,104 No SRE Bldg. 4,250 Yes SRE Bldg. (Heated) 2007 1,104 No St. George Hotel No St. George Island School 14,352 No Store No Tanaq Corp. Office Bldg.No Low Notes Aleutian HA Aleutian HA 41 6 5 9 3 10 0 2 Earlier 1940s 1950s 1960s 1970s 1980s 1990s 2000‐11 Age of Housing Stock                                       13%0% 87% Retrofitted BEES Certified Untouched Energy Efficient Housing Stock Community Profile: Saint Paul Incorporation 2nd Class City Location Longitude ‐170.275 Latitude 57.1222 ANCSA Region Aleut Corporation Borough/CA Aleutians West Census Area School District Pribilof School District AEA Region Aleutians Alaska Native Name (definition)Taxes   Type (rate) Per‐Capita Revenue Tamax ̂ Amix̂Sales (3%), Raw Fish (3%) 5,400$               Historical Setting / Cultural Resources Economy Climate Avg. Temp Climate Zone Heating Deg. Days 35.4 7 11,178 Year 2008 Notes Community Plans Year Local Contacts Phone Fax phyllis@stpaulak.com 907‐546‐3100 907‐546‐3188 907‐546‐3200 907‐546‐3253 907‐278‐2312 907‐278‐2350 Demographics 2000 2010 2013 Population 532 479 Percent of Residents Employed 68% Median Age 32 35 Denali Commission Distressed Community No Avg. Household Size 33 Percent Alaska Native/American Indian (2010)82.25% Median Household Income $50,750 $38,750 Low and Moderate Income (LMI) Percent  (2014)48.2% Electric Utility Generation Sources Interties PCE? Yes Landfill Class 3 Permitted?Yes Location Water/Wastewater System City of St. Paul Homes Served System Volume Water Sewer Energy Audit? Notes Access Road Air Access Runway 6,500' x 150' Dock/Port Barge Access?Yes Ferry Service?No Notes Local Multi‐Hazard Mitigation Plan Integrate TDX wind turbines into grid & add wind turbines;  Feasibility of heating with electric boilers/excess wind;  Emergency energy generation for essential services;  Upgrade diesel power system; Determine cause of line loss;  Shared fuel storage with St. George; Store aviation fuel near  airport Aleuts traveled to the Pribilofs seasonally for hunting. In  1870, the US government awarded the Alaska Commercial  Company a sealing lease.  Fur seals were over‐harvested,  and poverty ensued. During World War II, the Pribilof Aleuts  were confined in to Funter Bay. In 1979, Aleut Islanders  received $8.5M in compensation for this  treatment.  Commercial harvesting ceased in 1985.  Energy Priorities and Projects St. Paul lies 47 miles north of St. George Island, 240 miles north  of the Aleutian Islands, 300 miles west of the Alaska mainland,  and 750 air miles west of Anchorage. Local government, professional/business services, and trade are  the main employers. Natural Hazard Plan Yes City of St. Paul Saint Paul Island president@aleut.com Publicly Owned; Asphalt Yes St. Paul Email  No Tanadgusix Corporation TDX, LLC; City of St. Paul Diesel, Wind No Piped 747 1,000,001 ‐  5,000,000 gpd  (water) Piped Energy Profile: Saint Paul Diesel Power System Power Production Utility Diesel (kWh/yr)3,777,959 Avg. Load (kW)444 Engine Make/Model Condition/Hrs Gen Capacity Wind (kWh/yr)569,448 Peak Load (kW)904 Unit 1 Caterpillar Fair/66,694 855 Hydro (kWh/yr)0 Efficiency (kWh/gal)14 Unit 2 Caterpillar Fair/40,804 260 Total (kWh/yr)4,347,407 Diesel Used (gals/yr)270,929 Unit 3 Caterpillar Fair/45,696 300 Unit 4 Caterpillar Fair/22,229 650 Unit 5 Caterpillar Fair/19,815 480 Line Loss Heat Recovery? Upgrades Priority Projects Status RPSU Powerhouse High RPSU Distribution Med. Outage History/Known Issues Operators No. of Operators 2 APPO, BFO, PPO Electric Rates ($/kWh) Cost per kWh Sold ($/kWh)  Maintenance Planning (RPSU)Excellent Rate with PCE $0.17 Fuel Cost $0.36 Electric Sales No. of Customers kWh/year kWh/Customer Residential Rate $0.52 Non‐fuel Cost $0.21 Residential 149 790,380 5,305                   Commercial Rate Total Cost $0.57 Community 31 639,176 20,619                 Fuel Prices ($)Utility/Wholesale Retail Month/Year Commercial 50 2,137,559 42,751                 Diesel (1 gal)$4.85 $5.20 6‐13; 8‐14 Utility Use 182,965 Other Fuel? (1 gal) Gasoline (1 gal) Propane (100#) Wood (1 cord) Pellets Discounts? Alternative Energy Hydroelectric Wind Diesel Biomass Solar Geothermal Oil and Gas Coal Emerging Tech Heat Recovery Energy Efficiency Bulk Fuel Purchasing Deliveries/Year Gallons/Delivery Vendor(s) Tank Owner Fuel Type(s) Capacity Age/Condition By Barge Petro M.; Delta W City of St. Paul #2 Diesel 1,847,500 27 yrs. By Air TDX #2 Diesel 1,500,000 Cooperative Purchasing Agreements Trident Seafoods #2 Diesel 12,000 Bulk Fuel Upgrade Priority Project Status Notes High CompleteAHFC‐C,R Not Rated Low Operating Low Low Diesel Generator Heat Recovery Pending Low High Operating/not supplied to St. Paul Low St. Paul Wind Diesel Project, 675 kW Potential Status Low Projects Saint Paul Municipal Electric 13.7% Yes; Motor Pool, Public Works, Fire Station Two outages in 2012 due to overheating and pressure loss. Training/Certifications 21% 17% 57% 5% Residential Community Commercial Utility Use Electric Sales by Customer Type (kWh/year) 0 1000 2000 3000 4000 5000 6000 2010 2011 2012 2013 2014Electric Generation (MWh)Diesel Hydro Wind Energy Profile: Saint Paul Housing Units Occupied Vacant % Owner‐Occup.Regional Housing Authority Weatherization Service Provider 263 50 50% Housing Need Overcrowded 1‐star Energy Use Average Home Average Avg. EUI  10.3% N/A Energy Rating Square Feet (kBTU/sf) Data Quality N/A N/A N/A Street Lighting Owner Number/Type Retrofitted? Year Non‐residential Building Inventory Building Name or Location Year Built Square Feet Audited? Retrofits Done? In ARIS? AC Commercial Company Store 13,896 No ARFF Bldg. 3,200 Yes City Hall 1940 14,000 Yes Civic Center 1,200 Yes Fire Station 1 2009 5,947 Yes Fire Station 2 2009 5,970 Yes Landfills 4,400 No Machine Shop 2002 21,990 No Machine Shop 1 2002 21,800 Yes Machine Shop 2 2002 21,990 Yes Polar Star 2002 12,000 Yes Pribilof Island School District Office 1950 3,566 Yes Public Works Bldg./Maintenance Bldg. 1 2002 9,600 Yes Public Works Bldg./Maintenance Bldg. 2 2002 9,725 Yes Recreation Center No Saint Paul School 1973 33,050 Yes Yes SRE Bldg. (Heated) 2006 3,500 Yes Tanadguisiz Corporation No Tribal Admin. Office No Med. Notes Aleutian HA Aleutian HA 40 22 19 14 82 78 44 14 Earlier 1940s 1950s 1960s 1970s 1980s 1990s 2000‐11 Age of Housing Stock                                       16%3% 80% Retrofitted BEES Certified Untouched Energy Efficient Housing Stock Community Profile: Unalaska Incorporation 1st Class City Location Longitude ‐166.5367 Latitude 53.8736 ANCSA Region Aleut Corporation Borough/CA Aleutians West Census Area School District Unalaska City School District AEA Region Aleutians Alaska Native Name (definition)Taxes   Type (rate) Per‐Capita Revenue Ounalashka ("Near the Peninsula") Property, Sales (3%), Bed (5%), Raw Fish (2%) 4,660$               Historical Setting / Cultural Resources Economy Climate Avg. Temp Climate Zone Heating Deg. Days 40.9 7 9,014 Year 2013 Notes Community Plans Year Unalaska Economic Development Plan 2004 Local Contacts Phone Fax 907‐581‐1251 907‐581‐1417 907‐581‐2920 907‐581‐3644 907‐581‐1276 907‐581‐1496 Demographics 2000 2010 2013 Population 4,283 4,376 Percent of Residents Employed 83.5% Median Age 37 41 Denali Commission Distressed Community No Avg. Household Size 33 Percent Alaska Native/American Indian (2010)6.12% Median Household Income $69,539 $89,706 Low and Moderate Income (LMI) Percent  (2014)26.0% Electric Utility Generation Sources Interties PCE? Yes Landfill Class 1 Permitted?Yes Location Water/Wastewater System City of Unalaska Homes Served System Volume Water 9200 Sewer Energy Audit? Notes Access Road Air Access Runway 4100'x100' Dock/Port Barge Access?Yes Ferry Service?Seasonal Notes Continue wind study; biomass‐ solid waste incineration for  heat; investigate solar uses; Update Pyramid and Shaishnikof  Creeks hydro plans; heart recovery; heat pumps; integrate  private powerhouses; LNG; expand use of waste heat Unalaska overlooks Iliuliuk Bay and Dutch Harbor on Unalaska  Island in the Aleutian Chain. It lies 800 air miles from Anchorage  and 1,700 miles northwest of Seattle. Dutch Harbor is within the  boundaries of the City of Unalaska. Manufacturing, transportation/warehousing, and trade are the  main employers. Natural Hazard Plan No Unalaska LHMP Email  City of Unalaska Ounalashka Corporation City of Unalaska Diesel Qawalangin Tribe Piped Piped Yes The native Unangan people have inhabited the island of  Unalaska for more than 3,000 years. Since Aleuts were not  forced to give up their language or culture by the Russian  Orthodox priests, the church became strong in the community.  During WWII, almost all of the Aleuts on the Island were  interned for the duration of World War II.  Energy Priorities and Projects No Publicly owned; Asphalt Yes Unalaska 5M ‐ 10M gpd  (water); 1M ‐ 5M  gpd (ww) Energy Profile: Unalaska Diesel Power System Power Production Utility Diesel (kWh/yr)48,097,173 Avg. Load (kW)4,583 Engine Make/Model Condition/Hrs Gen Capacity Wind (kWh/yr)0 Peak Load (kW)8,840 Unit 1 Wartsila Good/8,831 5,400 Hydro (kWh/yr)0 Efficiency (kWh/gal)15.7 Unit 2 Wartsila Good/8,549 5,400 Total (kWh/yr)48,097,173 Diesel Used (gals/yr)3,068,848 Unit 3 Caterpillar Good/2,942 4,600 Unit 4 Caterpillar Fair/161,819 1,180 Unit 5 Caterpillar Fair/161,819 1,230 Unit 6 Caterpillar Good/29 250 Unit 7 Caterpillar Fair 1,000 Line Loss Heat Recovery? Upgrades Priority Projects Status RPSU Powerhouse Med. RPSU Distribution Low Outage History/Known Issues Operators No. of Operators Electric Rates ($/kWh) Cost per kWh Sold ($/kWh) 1 PPO Rate with PCE $0.23 Fuel Cost $0.22 Residential Rate $0.46 Non‐fuel Cost $0.07  Maintenance Planning (RPSU)Excellent Commercial Rate Total Cost $0.29 Electric Sales No. of Customers kWh/year kWh/Customer Fuel Prices ($)Utility Retail Month/Year Residential 709 3,804,889 5,367                    Diesel (1 gal)$3.47 $4.64 6‐13; 8‐14 Community 57 3,016,586 52,923                  Other Fuel? (1 gal) Commercial 206 38,380,755 186,314               Gasoline (1 gal)$4.59 6‐13 Utility Use 975,392 Propane (100#)$120.48 8‐14 Wood (1 cord) Pellets Discounts? Alternative Energy Hydroelectric Wind Diesel Biomass Solar Geothermal Oil and Gas Coal Emerging Tech Heat Recovery Energy Efficiency Bulk Fuel Purchasing Deliveries/Year Gallons/Delivery Vendor(s) Tank Owner Fuel Type(s) Capacity Age/Condition By Barge Frequent Delta Western Diesel/Gas. 16,000,000 By Air Petro Star Diesel/Gas 4,000,000 Cooperative Purchasing Agreements Bulk Fuel Upgrade Priority Project Status Notes High CompleteEECBG, ACEA, AHFC‐R, Streetlight Upgrade Not Rated Low Construction Low Low HR to electric, 200kW Rankine Cycle generator Pending Medium Not pursuing; feasibility study High Low Geothermal exploration; heat pumps Potential Status High Projects Training/Certifications City of Unalaska 4.0% Yes; Power plant building heat PCE reporting errors due to meter malfunctions. RPSU includes Dutch Harbor 8%7% 83% 2% Residential Community Commercial Utility Use Electric Sales by Customer Type (kWh/year) 0 10 20 30 40 50 60 2010 2011 2012 2013 2014Electric Generation (GWh)Diesel Hydro Wind Energy Profile: Unalaska Housing Units Occupied Vacant % Owner‐Occup.Regional Housing Authority Weatherization Service Provider 834 141 31% Housing Need Overcrowded 1‐star Energy Use Average Home Average Avg. EUI  9.5% 7.8%Energy Rating Square Feet (kBTU/sf) Data Quality 2 star plus 1,469 123 Street Lighting Owner Number/Type Retrofitted? Year 163 /HPS Yes 2012 Non‐residential Building Inventory Building Name or Location Year Built Square Feet Audited? Retrofits Done? In ARIS? Aerology Museum 4,236 No Alyeska Seafood, LLC.No Amaknak Fire Station No Ballyhoo Dock No Bowling Alley No C&M Breakwater No Carl E. Moses Small Boar Harbor No Carl's Bayview Inn No Chemical Storage Bldg.No Church of the Holy Ascension, Russian Orthodox No Court Bldg.No Dutch Harbor Post Office No Eagle's View Elementary Achigaalux No Employee Housing Yes Father Ishmail Gromoff Senior Center No Icicle Seafoods No Iliuliuk Medical Center No Museum of the Aleutians/WWII Nat'l. Park No North Pacific Fuel No OC Office No Off Shore Systems Inc.No Oonalaska Wellness Center No Ounalashka Corporation Office No Public Library No Qawalangin Tribal Office No Radiant Heating Fuel Service No Robert Storrs Int'l. Small Boat Harbor No Royal Aleutian Seafoods No Seaplane Base No State Troopers Post No The Grand Aleutian No Trident Bunkhouse No High Notes Replaced with LEDs Aleutian HA Aleutian HA 21 219 37 49 100 307 119 43 Earlier 1940s 1950s 1960s 1970s 1980s 1990s 2000‐11 Age of Housing Stock                                        6%0% 94% Retrofitted BEES Certified Untouched Energy Efficient Housing Stock Appendix A Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | A-1 A | S TAKEHOLDER P ARTICIPATION Community/Utility Interviews, Summer 2015 SWAMC staff conducted phone interviews from May to August 2015 to get updates on energy projects and priorities from the following community and utility representatives. Table 26: Community/utility interviews, May-Aug 2015 Community Name Position Adak Layton Lockett City Manager Akutan Mary Tesche Asst. City Administrator Atka Julie Dirks City Administrator Cold Bay Gary Ferguson Electric Utility Owner/Manager False Pass Chris Emrich Bookkeeper/Clerk King Cove Gary Hennigh City Administrator Nelson Lagoon Paul Gunderson Tribe President Sand Point Andy Varner City Administrator St. George Patrick Pletnikoff Mayor St. Paul Phyllis Swetzof City Clerk Unalaska Don Moore Interim City Manager Dan Winters Director of Public Utilities Aleutian Energy Summit, March 2015 The following individuals and organizations participated in the regional energy summit held on March 3, 2015 in conjunction with the SWAMC Annual Meeting. Table 27: Aleutian Energy Summit attendance, March 2015 Organization Name Role Local Government / Public Utilities City of Adak (also representing SWAMC Board) Layton Lockett City of Akutan Mary Tesche City of Atka Julie Dirks City of King Cove Gary Hennigh Speaker City of St. George Pat Pletnikoff City of St. Paul (also representing CBSFA) Jeff Kauffman City of Unalaska Chris Hladick Shirley Marquardt Nelson Lagoon Tribal Council Paul Gunderson Qagan Tayagungin Tribe (Sand Point) Tiffany Jackson Appendix A Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | A-2 Organization Name Role Private Industry Private Utilities / Independent Power Producers G&K Utility (Cold Bay) Gary Ferguson TDX Power (Adak, Sand Point, St. Paul) Kord Christianson Speaker James Dunn Agafon Krukoff Fuel Vendors Frosty Fuels (Cold Bay) Michael Tickle Vitus Marine Mark Smith ESCO Services Siemens, Inc. Amber McDonough Speaker Other Shumagin Corporation (Sand Point) Charlotte Gunderson Westward Seafoods / Alyeska Seafoods (Dutch Harbor) Sinclair Wilt Crimp & Associates Peter Crimp Planner Information Insights Jamie Hansen Speaker, Planner Resource Agencies Regional Aleutian Housing Authority Dan Duame Resource Panel Aleutian Pribilof Island Association Bruce Wright Aleutian Pribilof Island Community Development Association Angel Drobnica Southwest Alaska Municipal Conference Erik O’Brien Planner Laura Vaught Planner State (Government, Nonprofit & Educational) Alaska Energy Authority Katie Conway Speaker Josh Craft Speaker Jed Drolet Resource Panel Chris Gobah Jessie Huff David Lockard Speaker Alaska Housing Finance Corporation Scott Waterman Speaker, Panel Alaska Industrial Development and Export Authority Mike Catsi Speaker Alaska Native Tribal Health Consortium Gavin Dixon Resource Panel DCCED DCRA Bulk Fuel Loan Program Jane Sullivan Speaker UAF Interior-Aleutians Campus Mike Hirt Resource Panel Bryan Uher Resource Panel Federal U.S. Department of Energy Givey Kochanowski Resource Panel USDA Rural Development Jolene John Resource Panel Appendix A Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | A-1 Online Survey, Spring 2014 An online survey of community and regional stakeholders was conducted at the end of Phase I to identify any errors in the Phase I Resource Inventory and gather input on broadly supported energy projects and priorities. The following individuals completed the survey. Table 28: Online survey respondents, Feb-April 2014 Community Organization Name Title Local Government, Utility and Industry Adak City of Adak Layton J. Lockett City Manager Akutan City of Akutan Tuna Scanlan Mary Tesche Asst. City Administrator RMA Consulting Group Raymond Mann Atka City of Atka Jennifer Kost City Clerk Cold Bay City of Cold Bay Dawn Lyons City Clerk/Administrator G&K, Inc. Gary Ferguson President False Pass City of False Pass Chris Emrich Isanotski Corporation Sue Parker Manager King Cove Agdaagux Tribal Council Della Trumble City of King Cove Gary Hennigh City Administrator Peter Pan Seafoods (King Cove) Glenn Guffey Plant Manager Nelson Lagoon Nelson Lagoon Tribal Council & Corp. Paul (Butch) Gundersen President Nikolski Nikolski Clinic Doris Kompkoff CHP/C Sand Point City of Sand Point Andy Varner Administrator Qagan Tayagungin Tribe of Sand Point Jason Bjornstad Tiffany Jackson Executive Director Shumagin Corporation Glen Gardner Jr. President St. George City of St. George Patrick Pletnikoff Mayor St. Paul City of St. Paul Kenneth Weaver, PhD ICMA-CM St. Paul Fishing Company, LLC Jeff Kauffman CEO TDX Power Kord Christianson President Ron Philemonoff Chairman Unalaska / Dutch Harbor City of Unalaska Chris Hladick City Manager Daniel Winters Ounalashka Corporation David Gregory UniSea, Inc. Tom Enlow Executive VP Westward Seafoods / Alyeska Seafoods Sinclair Wilt VP, Fisheries Specialist Regional Government, Nonprofit and Native Organizations Regional Aleutian Housing Authority Dan Duame Executive Director Aleutian Pribilof Island Community Development Association Angel Drobnica Renewable Energy and Fisheries Liaison Aleutian Pribilof Islands Association Bruce Wright Appendix A Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | A-2 Community Organization Name Title Aleutians East Borough Ernest Weiss Natural Resources Director Eastern Aleutian Tribes Edgar Smith Operations Director Jennifer Harrison Executive Director The Aleut Corporation Janet Reiser Schools Aleutian Region School District Joseph Beckford Aleutians East Borough School District Doug Conboy Superintendent Pribilof School District Connie A. Newman Superintendent Other Petro Star Inc. Don Castle VP Sales & Operations Appendix B Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | B-1 B | A NALYSIS OF R ESOURCE P OTE NTIAL The data in the following tables has been compiled from multiple sources including the Alaska Energy Data Gateway (25), the Renewable Energy Atlas of Alaska (26), the Alaska Energy Efficiency Map (19), the Division of Geological & Geophysical Services report, Fossil Fuel and Geothermal Energy Sources for Local Use in Alaska (27), personal communication with Alaska Energy Authority program managers for Biomass Energy, Geothermal Energy, Heat Recovery, Hydroelectric Power, and Wind Energy, and data shared by the region’s electric utilities. Note that each table estimates the savings potential from new, community- or utility-scale energy projects. The analysis does not reflect the value of infrastructure or programs already in place . Except in the case of energy efficiency, it does not look at opportunity from residential- or building-scale projects. This is an important caveat especially in the area of solar and biomass technologies, where a low rating for community- or utility-scale solutions does not mean there is not significant potential to save money from residential projects. The rating criteria for individual resources were developed in collaboration with AEA program managers. See Table 37 for an explanation of the criteria used in the analysis. Table 29: Wood biomass resource potential 20-Year Average Diesel Fuel Price ($) Resource Potential Productive Forest Project in Operation Rough B/C Ratio Existing Study (R,F) or Development (D,C) Certainty Adak 5.80 L L NA NA L Akutan 4.72 L L NA NA L Atka 5.80 L L NA NA L Cold Bay 5.65 L L NA NA L False Pass 4.17 L L NA NA L King Cove 4.19 L L NA NA L Nelson Lagoon 5.30 L L NA NA L Nikolski 5.80 L L NA NA L Saint George 6.89 L L NA NA L Saint Paul 5.15 L L NA NA L Sand Point 5.19 L L NA NA L Unalaska 3.99 L L NA NA L See Page B-7 for data sources and notes. Appendix B Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | B-2 Table 30: Geothermal resource potential Resource Potential Identified Resource within 20 Miles Significant Resource within 20 Miles Certainty Adak M Y L Akutan M Y L Atka M Y L Cold Bay L L False Pass L L King Cove L L Nelson Lagoon L L Nikolski L L Saint George L L Saint Paul L L Sand Point L L Unalaska M Y L See Page B-7 for data sources and notes Table 31: Hydropower resource potential Resource Potential Projects in Operation Hydro Resource Identified in Pathway Existing Study (R,F) or Development (D,C) Viable Resource based on Visual Assessment Certainty Adak H Y NA NA H M Akutan H Y Y NA NA H H Atka H Y Y NA NA H H Cold Bay M Y NA NA M M False Pass H Y NA NA H M King Cove H Y Y NA NA H H Nelson Lagoon L Y NA NA L M Nikolski L Y NA NA L M Saint George L NA NA L M Saint Paul L NA NA L M Sand Point L Y NA NA L M Unalaska H Y NA NA H M See Page B-7 for data sources and notes. Appendix B Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | B-3 Table 32: Wind energy resource potential Resource Potential Wind Resource Developability Site Accessible Permitability Site Availability Load Certainty Notes Adak H H H Y Y Y Y L Concern related to existing oversized generation system. Akutan L H L Y Y L Load <100 kw Atka M H M Y Y Y NA L Need load from Atka pride Cold Bay H H H Y Y Y Y H False Pass L H L Y Y Y H CDR by Marsh Creek. Need RPSU. King Cove H H H Y Y Y Y L One study found turbulence; other sites likely available but not studied Nelson Lagoon L H L Y Y M Permitting difficult because on spit. Monopole anemometer, vane onsite. Nikolski L H L Y Y Y H Project in place but not functioning. Saint George H H H Y Y Y Y H RPSU completed. Project to operate soon. Saint Paul H H H Y Y Y Y H Operating Sand Point H H H Y Y Y Y H Operating Unalaska H H H Y Y Y Y L 1999 study indicated strong turbulence, no met tower installed. See Page B-7 for data sources and notes. Appendix B Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | B-4 Table 34: Oil and gas resource potential Resource Potential Source Rock, Traps and Reservoirs Present Wells Drilled, Economic Resource Identified Certainty Notes Adak L NA NA L Additional drilling may be warranted Akutan L NA NA L Atka L NA NA L Cold Bay L NA NA L False Pass L NA NA L King Cove L NA NA L Nelson Lagoon L NA NA L Nikolski L NA NA L Saint George L NA NA L Saint Paul L NA NA L Sand Point L NA NA L Unalaska L NA NA L See Page B-7 for data sources and notes. Table 33: Coal resource potential Resource Potential Potential Deposits Identified High Quality/ Developability Project Planned or in Development Certainty Adak L NA L Akutan L NA L Atka L NA L Cold Bay L Y NA L False Pass L Y NA L King Cove L Y NA L Nelson Lagoon L Y NA L Nikolski L NA L Saint George L NA L Saint Paul L NA L Sand Point L Y NA L Unalaska L NA L Note: The Herendeen Bay Field and Unga Island Field are the two main southern peninsula regions with coal exposures. Villages within 100 miles include Port Heiden, Nelson Lagoon, Sand Point, King Cove, Cold Bay, and False Pass. See Page B-7 for data sources and notes. Appendix B Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | B-5 Table 35: Heat recovery resource (HR) potential Resource Potential HR Equipment at Powerhouse HR in Operation Recoverable Heat Available Nearby Thermal Loads Existing Study (R,F) or Development (D,C) Certainty Notes Adak M Y Y NA L Needs RPSU first. Akutan M NA NA NA L Possible RPSU. Atka L NA NA H Possible hydro heat recovery after controls upgraded. Cold Bay M Y Y F M False Pass H Y Y Y NA M Existing system failed; needs feasibility evaluation. King Cove L Y Y NA NA H Nelson Lagoon M NA NA NA NA NA L Needs RPSU, no information. Nikolski L Y NA NA NA M Based on RPSU database. Saint George L Y Y NA AEA CDR H Saint Paul L Y Y NA C H Construction complete Sand Point H Y Y Y Y NA M Information from 2012 RPSU survey. Unalaska L Y Y NA NA H Organic Rankine Cycle system operational; electrotherm data to be verified See Page B-7 for data sources and notes. Appendix B Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | B-6 Table 36: Energy Efficiency savings potential Resource Potential Residential EE Potential % of Homes without HER or AHFC/RHA Weatherization Commercial/Public Building EE Potential Water/Sewer System Audit School Audit Street Light Upgrades Community EE Program (VEEP, EECBG, etc.) or Multiple Commercial Building Audits Certainty Adak H H 100% H Y H Akutan M L 0% H Y H Atka H M 50% H Y Y H Cold Bay H H 100% H Y Y H False Pass H M 50% H Y Y H King Cove H M 54% H Y Y Y H Nelson Lagoon H M 43% H H Nikolski H M 52% H H Saint George H H 87% H Y H Saint Paul H H 80% H Y Y H Sand Point H H 71% H Y Y Y H Unalaska H H 94% H Y Y H See Page B-7 for data sources and notes. Appendix B Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | B-7 Table 37: Criteria used in resource potential analysis Resource Potential Certainty Resource What it Includes Low Medium High Low Medium High Alternative Power Generation Coal Resource development* and power generation Local, quality resource absent. Quality resource identified; further study needed High quality, local resource identified; project in development No information documented. Based on documented opinion of credible source or recon level study. Based on feasibility or higher level study . Geothermal Resource development and power generation No documented resource within 20 miles. Significant resource within 20 miles. Significant resource within economic distance. " " " Hydro Resource development and power generation No hydro resource present or, if present, economic viability is nil to highly unlikely based on visual inspection. Economic viability is unlikely to possible based on visual inspection. Hydro project is present or under construction. Or, economic viability is possible to highly likely based on visual inspection. No information documented. Based on documented opinion of credible source or recon level study, including hydro database. Based on feasibility or higher level study . Hydrokinetic Resource development and power generation No river, tidal or wave energy potential documented within 10 miles. Substantial resource documented within 10 miles. Substantial resource adjacent to power system. " " " Oil & Natural Gas Resource development and power generation No source rock, traps or reservoirs present. Source rock, traps or reservoirs present. Needs investigation. Wells drilled and economic resource identified. " " " Solar Photovoltaic Economic criteria are more important than resource data. Projects should be evaluated on a case-by-case basis. See notes on solar technologies following table. Wind Resource development and power generation Wind resource or developability low***. " Project in operation, or wind resource and developability high***. " Based on recon level study. Resource based on 12+ months onsite resource assessment, hourly load data, feasibility or higher level study. Other Nuclear, emerging energy technology Low (See notes on emerging technologies following table.) Appendix B Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | B-8 Resource Potential Certainty Resource What it Includes Low Medium High Low Medium High Heat Biomass Resource development and heat generation Low productivity of nearby forest. And, if study is available, B/C ratio less than 1.0. Medium or higher productivity of nearby forest; and, B/C ratio between 1.0 and 1.5, based on either rough analysis**** or existing study. Medium or higher productivity of nearby forest; and B/C ratio greater than 1.5, based on either rough analysis**** or existing study. No information documented. Based on documented opinion of credible source or recon level study. Based on feasibility or higher level study . Heat Pumps Ground, sea water, and air source heat pumps Economic criteria are more important than resource data. Projects should be evaluated on a case-by-case basis. See notes following table on heat pumps in communiti es with diesel electric generation. Diesel Heat Recovery CHP from diesel, other Thermal loads remote from powerhouse, minimal recoverable heat remains. <---> HR equipment installed at powerhouse, thermal loads nearby, much recoverable heat remains. No information documented. Based on documented opinion of credible source or recon level study (e.g. power system inventory). Based on feasibility or higher level study (e.g. RPSU CDR). End User Efficiency - Based on residential & public/commercial ratings^ Residential More than 70% of homes have received recent EE upgrades 41 - 70% of homes have NOT received recent EE upgrades. Less than 40% of homes have NOT received recent EE upgrades Little to no information available on buildings or recent EE upgrades.^^ Little to no information available on buildings or recent EE upgrades. Public & Commercial See Note ^^ Completed all: Water/Sewer system audit, school audit, streetlight replacements, EECBG, AHFC Commercial or VEEP Completed 3 to 0 of the infrastructure audits/upgrades/progra ms Little to no information available on buildings or recent EE upgrades.^^^ Little to no information available on buildings or recent EE upgrades. Transmission Interties Power lines between communities or to remote generation Gas Lines Natural gas or LNG lines Appendix B Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | B-9 Resource Potential Certainty Resource What it Includes Low Medium High Low Medium High Notes * Resource development: Activities that include energy resource assessment, infrastructure development, transportation, fuel storage and handling. **Visual assessment by AEA hydro PM indication L=None to Highly Unlikely, M=Unlikely to Maybe, H=Maybe to Highly Likely *** Wind potential defined by two factors: 1. Wind resource: L=class 2 or lower, M=class 3-4, H=class 5 or higher. 2. Developability, Indicated by four factors (Y=yes, N=likely no, X=fundamental problem that indicates low wind potential) a. Access in place: is there a road, power transmission, or other suitable access to a viable wind site? b. Permitability: Can habitat, FAA, or other factors be resolved without significant difficulty? c. Site availability: Is there suitable land that is available for siting wind turbines? d. Load: Is there sufficient load such that wind can be integrated economically with the existing diesel system (X: less than 50 kW average load)? **** Rough analysis of biomass project benefit/cost estimated based on these assumptions: 1. Fuel price estimated as simple 20-year average of ISER projections of power-sector fuel price plus an adder of $0.50 per gallon for heating fuel (ftp://www.aidea.org/REFund/Round%208/Documents/EvaluationModel.xlsm) 2. Fuelwood with an energy content of 20 MMBtu/cord and price of $250/cord 3. Wood and oil combustion efficiency equal 4. Installed cost of system estimated at $35/gallons per year of displaced fuel 5. O&M cost of 1% installed cost Energy Efficiency Rating^ The rating is conservative in giving a high potential for communities with any high rating whether in residential or public/commercial. Medium ratings are used for communities with two mediums or a low and a high. No community is rated as low for overall energy efficiency potential. Energy Efficiency Low^^ Low is not used as a resource potential for public and commercial building energy efficiency because even if all programs and audits are completed there is substantial work left to be done on implementing retrofits. Where information on audits especially for public and commercial buildings is sufficient, information on whether retrofits have been implemented is often lacking. To reflect that these criteria are not the full story of energy efficiency in commercial and public infrastructure, this the low potential rating is not used. Energy Efficiency Certainty^^^ The assumption is audits and streetlights that have been completed are recorded by AHFC and EE programs are recorded in multiple locations - REAP, AK Energy Efficiency, and AEA. Therefore, these ratings are based on collected data and have a high level of certainty. Appendix B Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | B-10 Notes on Specific Technologies SOLAR P/V AND THERMAL In Alaska, the sun's energy is abundant in the summer when daylight hours are long. Owners and residents of off-grid lodges, fish camps, and remote cabins may find solar photovoltaic or solar thermal systems to be viable options. However, long, dark winters with six or more months of snow cover in most of the state make the economics of solar energy challenging. This is particularly true when the economics of solar energy are compared to those of energy efficiency and conservation, which can provide similar fuel-saving benefits at a fraction of the cost of solar energy. The Alaska Energy Authority has funded the construction of one solar photovoltaic and one solar thermal project through the Renewable Energy Fund in recent years. Each of these projects was designed and constructed properly and is operating as anticipated. The Kaltag solar photovoltaic project cost $126,000 and saved $2,600 in energy costs in FY2014. The McKinley Village solar thermal project cost more than $190,000 and saved approximately $7,000 in FY2014. Once operations and maintenance costs are factored in, neither of these projects is likely to pay for itself over its expected life. The National Renewable Energy Laboratory (NREL) has developed a valuable tool for analyzing solar photovoltaic performance and economics. It is called PVWatt’s Calculator and is available at http://pvwatts.nrel.gov. Alaskans interested in learning about the potential for solar photovoltaic development can use PVWatt’s as a preliminary analysis tool to analyze solar potential at their site. NREL also has a tool for analyzing solar thermal projects call ed System Advisor Model (SAM) and is available at https://sam.nrel.gov. Alaska residents can request assistance from the Alaska Energy Authority (David Lockard at 907-771-3062) in performing either solar P/V or solar thermal analysis. HEAT PUMPS IN COMMUNITIES WITH DIESEL ELECTRICAL GENERATION Given the high installation costs and efficiency limitations of current technology, heat pumps do not appear economically competitive with fuel oil heaters in rural communities that rely on diesel for electrical generation. Heat pumps use a working fluid in a refrigeration cycle to move heat from a lower temperature source to a higher temperature load, consuming electricity in the process. Heat sources can include the ground (via glycol filled loops in vertical boreholes or horizontal trenches), air, ground water, lakes, and seawater. Heat pump performance is expressed as a ratio of thermal energy delivered to electrical energy consumed which is referred to as the Coefficient of Performance (COP). Unit oil fuel heaters typical of rural Alaska operate at approximately 90% efficiency. Diesel gen- set conversion efficiencies typical of rural Alaska communit ies are in the range of 30-35% (in other words, 30-35% of the energy available in diesel fuel is converted to electricity). Based on these assumptions, a heat pump would need to operate with a minimum average COP greater than of 2.5 in order to supply the same amount of heat from electricity generated from 1 gallon of diesel fuel as would be supplied by burning 1 gallon of diesel fuel. While this level of performance may be attainable in many areas of the state, the cost of installation —which Cold Climate Housing Research Center has estimated to range from $25,000 to $35,000 for ground Appendix B Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | B-11 source heat pump systems—almost certainly precludes the economic viability of heat pumps in communities reliant on diesel generation. Additional factors to take into account:  Powerhouse heat recovery adds significant additional value to each gallon of diesel consumed for electricity generation.  Transmission losses reduce the amount of electrical energy actually available per gallon of diesel.  Maintenance requiring specially trained technicians and equipment further increase operational costs. EMERGING TECHNOLOGIES River and marine hydrokinetics, including tidal and wave power, are emerging technologies with no commercial projects currently in operation in the United States. Considerable resources are being invested in advancement of the technologies at the state and federal level although at this point they are considered pre-commercial. Appendix C Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | C-1 C | C OMMUNITY I NPUT AND P RIORITIES Appendix D Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | D-1 D | W ORKS C ITED 1. Alaska Energy Authority. Power Cost Equalization Program Statistical Data by Community, Reporting Period: July 1, 2013 to June 30, 2014. 2015. 2. Your Clean Energy, LLC. Aleutian & Pribilof Islands Regional Energy Plan Resource Assessment. 2014. 3. TDX Power, Sand Point Generating. Renewable Energy Fund Round VIII Grant Application - Heat Projects. Anchorage, AK : Alaska Energy Authority. 4. Alaska Energy Authority. Round 5 Evaluations. Anchorage, AK : s.n. 5. Pletnikoff, Patrick. Abundant wind, efficient diesel cuts energy costs for St. George. Alaska Dispatch News. [Online] [Cited: September 24, 2015.] http://www.adn.com/article/20140915/abundant-wind-efficient-diesel-cuts-energy-costs-st- george. 6. Brister, Bill. TDX Adak Generating. [interv.] Doug Griffin. September 15, 2015. 7. Alaska Energy Authority. Alaska Renewable Energy Fund Status Report. 2015. 8. —. Renewable Energy Fund: Status Report and Round VIII Recommendations. 2015. 9. Heating Oil and Propane Update. U.S. Energy Information Administration. [Online] [Cited: September 26, 2015.] http://www.eia.gov/petroleum/heatingoilpropane/. 10. Winters, Dan. Director of Public Utilities. [interv.] Doug Griffin. September 2, 2015. 11. Alaska Department of Labor and Workforce Development. Population of Alaska by Economic Region, Borough and Census Area, 2010 to 2014. 2014. 12. —. Alaska Population Projections: 2012-2042. April 2014. 13. Alaska Department of Labor and Workforce Development, Research and Analysis Section. Population of Alaska by Economic Region, Borough and Census Area, 2000-2010. 2011. 14. Ray Mann, Program Manager, RMA Consulting. Akutan Geothermal Receives Additional Funding, Drilling Permit. In the Loop. August 31, 2015. 15. Wiltse, N., Madden, D., Valentine, B., Stevens, V. 2013 Alaska Housing Assessment. s.l. : Cold Climate Housing Research Center, 2014. Prepared for Alaska Housing Finance Corporation. 16. Ord, Jimmy. Alaska Housing Finance Corporation. April 9, 2013. 17. —. Alaska Housing Finance Corporation. Personal communication. January 13, 2014. 18. —. Alaska Housing Finance Corporation. Personal communication. January 2015. 19. Alaska Energy Authority. Alaska Energy Efficiency Map. March 26, 2013. 20. Alaska Native Tribal Health Consortium. Energy Audits. Alaska Native Tribal Health Consortium. [Online] [Cited: 12 12, 2012.] http://www.anthctoday.org/dehe/cbee/energyaudits.html. 21. Lockard, David. Alaska Energy Authority. Personal communication. July 7, 2014. 22. YourCleanEnergy. Aleutian & Pribilof Islands Regional Energy Plan Phase I Inventory (DRAFT). November 2013. Prepared for SWAMC. Appendix D Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | D-2 23. Waterman, Scott. Alaska Housing Finance Corporation. Personal communication. May 27, 2014. 24. Dixon, Gavin. ANTHC, Water System Audits. Personal Communication. December 2014. 25. Institute of Social and Economic Research. Alaska Energy Data Gateway. [prod.] Office of Science, Basic Energy Sciences (BES), under EPSCoR Award # DE-SC0004903 (database and web application development), and by Alaska Energy Authority (Renewable Energy Fund data management and reporting) U.S. Department of Energy (DOE). Anchorage, Alaska : s.n., 2015. 26. Geographic Information Network of Alaska. Renewable Energy Atlas of Alaska. Alaska Energy Data Inventory. [Online] 2013. [Cited: February 28, 2015.] http://www.akenergyinventory.org/atlas. 27. Swenson, Robert F., et al., [ed.]. Fossil Fuel and Geothermal Energy Sources for Local Use in Alaska. Special Report 66. Fairbanks, Alaska : Alaska Department of Natural Resources, Division of Geological & Geophysical Services, 2012. Appendix E Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | E-1 E | D ATA S OURCES Table 38: Data sources for community profiles Note: See page 7 for a list of acronyms. Source Date Source Date Alaska Native Name UAF 2014 Location DCRA 2014 Historical Setting DCRA 2014 Climate Avg. Temp ACRC; weatherbase.com Cultural Resources DCRA 2014 Climate Zone CCHRC 2014 Energy Priorities Phase I rpt, Phase II input 2015 HDD CCHRC 2014 Contacts City DCRA 2014 Taxes Alaska Taxable 2013 Tribal DCRA 2014 Economy DCRA 2014 Village Corp DCRA 2014 Natural Hazards Plan DMVA 2014 Community Plans DCRA 2014 Demographics Demographics (cont.) 2000 Population DCRA 2000 HH Income DCRA 2010 Median Age DCRA 2000 % Employed ALARI 2013 HH Size DCRA 2000 LMI%HUD 2014 % Native DCRA 2000 Distressed Denali Commission 2013 2010 Population DCRA 2010 Median Age DCRA 2010 HH Size DCRA 2010 % Native DCRA 2010 Landfill Class DCRA 2014 Landfill Location DCRA 2014 Permitted DCRA 2014 Condition/Life DCRA 2014 W/W System Water Phase I Report 2013 W/W Sys.Audited? Sewer Phase I Report 2013 Homes Served Condition Phase I Report 2013 Gallons Road Access DCRA 2014 Interties Air Access Owner DCRA 2014 Air Access Lighted FAA 2014 Runway (lxw)FAA 2014 Flight Rules FAA 2014 Surface FAA 2014 Condition FAA 2014 Dock/Port Facilities Ferry Service DCRA 2014 Notes Phase II public input 2015 Barge Access DCRA 2014 Appendix E Aleutian & Pribilof Islands Regional Energy Plan Phase II: Report Update | E-2 Table 39: Data sources for energy profiles Note: See page 7 for a list of acronyms. Source Date Source Date Utility Name DCRA 2014 Power Production Power House Diesel PCE, Utilities 2014 Engine Make RPSU (2012), Utilities (2015)Wind PCE, Utilities 2014 Line Loss PCE 2014 Hydro PCE, Utilities 2014 Heat Recovery RPSU 2012 Avg Load Alaska Energy Pathway 2010 Upgrades RPSU (2012), Utilities (2015)Peak Load Alaska Energy Pathway 2010 Outages/Issues RPSU 2012 Diesel Eff.PCE 2014 Operators Diesel Use PCE 2014 Number 5-yr Trend AEDG 2014 Training/Certs AEA Training Database 2014 Maint. Planning RPSU 2012 Electric Rates Residential PCE, Utilities 2014 Commercial PCE 2014 Electric Sales Customers PCE, Utilities 2014 Cost per kWh All PCE 2014 kWh sold PCE, Utilities 2014 Fuel Prices Utility AEDG, PCE 2014 Resources All See Appendix B 2015 Retail AEDG 2014 Discounts Bulk Fuel Tanks Other sources Fuel Vendor interviews 2015 Purchasing Coop Purchase Regional Housing Authority AHFC 2014 Other Wx Service Provider AHFC 2014 Energy Use Housing Units Occupied CCHRC 2014 Avg Star Rating CCHRC 2014 Vacant CCHRC 2014 Avg Sq Feet CCHRC 2014 Avg. EUI CCHRC 2014 Housing Need Overcrowded CCHRC 2014 EE Housing Stock Owners/Occup CCHRC 2014 Retrofitted CCHRC, AHFC 2014 Data Quality 1-star CCHRC 2014 Retrofitted Regional Housing Auth.2014 Retrofitted Wx Service Provider 2014 Housing Age By Decade CCHRC 2014 BEES Certified CCHRC, AHFC 2014 Non-residential Bldg Inventory ARIS (2014), DCRA maps (2008)Lighting All AHFC audit reports