Loading...
HomeMy WebLinkAboutRE Fund Round 2 Recommendation_v2Alaska Renewable Energy Fund Ranking and Proposed Grant Allocation Round 2 March 17, 2009 Page 1 of 4 Energy Region ID Project Name Applicant Applicant Type Project Type AEA Applicant 1. Cost of Energy (30) 2. Match (25) 3. Tech & Econ Feas (20) 4. Readiness (5) 5. Benefits (10) 6. Local Support (5) 7. Sustain- ability (5) Total (100) Statewide Rank Project Cost Grant Request Match Offered Aleutians 317 Sand Point Wind_AWE Aleutian Wind Energy / AWE IPP Wind 4.55 4.75 23 18 8 23 5 23 2 83 1 $3,104,443 $639,806 $437,900 $639,805 Full Funding Special Provision Lower Yukon- Kuskokwim 210 Kiseralik_Chikuminuk Hydro_AVCP Housing Association of Village Council Presidents Regional Housing Authority Government Entity Hydro 2.51 5.37 22 15 9 23 2 22 4 81 2 $400,000 $250,000 $150,000 $250,000 Full Funding North Slope 245 Barrow_Atqasuk Transmission North Slope Borough Local Government Transmission 2.55 3.43 30 14 8 18 3 30 2 79 3 $14,000,000 $400,000 $100,000 $175,000 Partial Funding Special Provision Aleutians 271 Unalaska Heat Recovery City of Unalaska, Department of Public Utilities Utility Local Government Heat Recovery 4.62 4.77 20 17 9 21 4 20 2 78 4 $2,011,412 $1,300,000 $619,807 $1,300,000 Full Funding Aleutians 315 Adak Diesel Hybrid_TDX Power TDX Adak Generating, LLC Utility Other 29 15 4 16 5 29 2 76 5 $900,000 $800,000 $100,000 $85,835 Partial Funding Yukon- Koyukuk/Upper Tanana 293 Venetie District Heat_Village Council Venetie Village Council Local Government Biomass 1 0.8 28 13 6 18 3 28 3 76 6 $1,308,500 $88,500 $20,000 $88,500 Full Funding Northwest Arctic 307 Ambler HR_City of Ambler City of Ambler Local Government Heat Recovery 1.34 1.57 30 14 6 14 5 30 2 75 7 $500,000 $435,000 $65,000 $435,000 Full Funding Special Provision Northwest Arctic 235 Kotzebue HR and Ammonia Power Cycle Kotzebue Electric Association Utility Heat Recovery 7.66 9.12 14 19 10 21 5 14 2 74 8 $1,215,627 $915,627 $300,000 $915,627 Full Funding Southeast 223 Neck Lake Hydro_APT Alaska Power & Telephone Company Utility Hydro 1.36 1.1 25 13 5 19 4 25 5 74 9 $2,440,000 $1,952,000 $488,000 $108,000 Partial Funding Special Provision Copper River/Chugach 236 Fivemile Creek_Chitna Electric Chitna Electric Inc, (CEI)Utility Hydro 1.83 2.41 22 17 9 16 4 22 2 74 10 $4,659,500 $4,159,500 $500,000 $303,000 Partial Funding Special Provision Lower Yukon-Kuskokwim 273 Tuntutuliak High Penetration Wind Diesel Tuntutuliak Community Services Association Utility Wind 1.56 1.94 20 14 7 22 4 20 4 73 11 $3,360,000 $1,760,000 $1,600,000 $1,760,000 Full Funding Special Provision Southeast 277 Angoon HR_IPEC Inside Passage Electric Company Utility Heat Recovery 2.26 3 23 17 8 15 5 23 0 72 12 $617,934 $545,934 $72,000 $545,934 Full Funding Copper River/Chugach 226 Carlson Creek Hydro_APT Alaska Power Company (a subsidiary of Alaska Power & Telephone Company)Utility Hydro 1.04 0.99 28 12 5 19 3 28 0 71 13 $6,300,000 $520,000 $130,000 $40,000 Partial Funding Copper River/Chugach 316 Tatitlek High Penetration Wind Tatitlek IRA Council/ Tatitlek Electric Utility Government Entity Wind 1.16 1.31 29 14 6 10 3 29 4 70 14 $1,672,388 $164,358 $8,030 $138,210 Partial Funding Aleutians 306 Aleutian Peninsula Broadcasting Wind Aleutian Peninsula Broadcasting, Inc.IPP Wind 1.66 1.72 23 13 8 18 2 23 3 68 15 $146,750 $126,750 $20,000 $126,750 Full Funding Special Provision Kodiak 215 Terror Lake Capacity_KEA Kodiak Electric Association, Inc. (KEA)Utility Hydro 7.31 6.53 5 19 9 23 5 5 2 68 16 $15,907,950 $500,000 $500,000 $500,000 Full Funding Bering Straits 303 Shaktoolik Wind_AVEC Alaska Village Cooperative (AVEC)Utility Wind 1.51 1.84 18 15 6 16 5 18 2 66 17 $2,727,960 $2,465,664 $262,296 $2,465,664 Full Funding Yukon- Koyukuk/Upper Tanana 314 McGrath Biomass Feasibility McGrath Traditional Council Government Entity Biomass 0 0 23 15 4 17 4 23 3 65 18 $43,940 $34,740 $9,200 $34,740 Full Funding Special Provision Bering Straits 297 Teller Wind Analysis_AVEC Alaska Village Electric Cooperative (AVEC)Utility Wind 1.56 1.56 21 16 7 10 5 21 2 65 19 $4,436,800 $117,610 $6,190 $117,610 Full Funding Bristol Bay 265 Kvichak River_Igiugig Igiugig Village Council d/b/a Igiugig Electric Company Utility Ocean/River 0.36 0.39 23 14 5 11 4 23 5 65 20 $2,396,830 $2,302,630 $94,200 $718,175 Partial Funding Special Provision North Slope 244 Point Lay Heat Recovery North Slope Borough Local Government Heat Recovery 1.37 1.64 21 13 7 14 3 21 2 64 21 $4,257,116 $3,995,116 $262,000 $395,912 Partial Funding Lower Yukon- Kuskokwim 302 Emmonak Wind and Transmission_AVEC Alaska Village Cooperative (AVCP)Utility Wind 0.99 0.91 18 13 5 17 4 18 2 63 22 $10,733,179 $9,670,361 $1,062,818 $9,670,361 Full Funding Special Provision Southeast 211 Thorne Baywood Boiler_SEISD Southeast Island School District for Thorne Bay School Government Entity Biomass 3.18 3.75 10 17 9 18 4 10 0 62 23 $220,179 $178,179 $42,000 $178,179 Full Funding Bering Straits 205 Banner Wind Construction_Nome Banner Wind, LLC IPP Wind 1.63 1.88 12 14 8 20 2 12 5 62 24 $5,157,000 $4,126,000 $1,031,000 $4,126,000 Full Funding Special Provision Lower Yukon- Kuskokwim 299 Scammon Bay Wind Analysis_AVEC Alaska Village Electric Cooperative (AVEC)Utility Wind 1.3 1.3 20 14 7 10 4 20 2 62 25 $4,436,800 $117,610 $6,190 $117,610 Full Funding Railbelt 222 Kenai Winds_Nikiski Kenai Winds, LLC IPP Wind 1.09 0.98 5 13 5 25 5 5 5 61 26 $21,000,000 $5,850,000 $15,150,000 $5,850,000 Full Funding Special Provision Copper River/Chugach 218 Cordova District Heat_NVE Native Village of Eyak Government Entity Biomass 2.07 7.52 12 16 9 11 4 12 5 61 27 $1,850,320 $1,850,320 $27,750 $50,000 Partial Funding Southeast 305 Connelly Lake Hydro_APT Alaska Power and Telephone Co Utility Hydro 1.88 1.94 9 14 7 19 3 9 5 60 28 $33,235,000 $988,000 $247,000 $428,000 Partial Funding Special Provision Lower Yukon- Kuskokwim 298 St. Mary's Wind Analysis_AVEC Alaska Village Electric Cooperative (AVEC)Utility Wind 1.44 1.44 18 15 7 10 4 18 2 60 29 $6,310,000 $110,000 $5,500 $110,000 Full Funding North Slope 243 Wainwright Heat Recovery North Slope Borough Local Government Heat Recovery 1.14 1.14 18 13 7 14 3 18 2 60 30 $3,612,000 $3,300,000 $312,000 $300,000 Partial Funding Southeast 231 Crooked Creek Hydro_Elfin Cove Community of Elfin Cove Non-Profit Corporation, Elfin Cove Utility Commission Utility Hydro 1.66 1.96 16 13 7 15 3 16 3 60 31 $2,203,497 $347,200 $48,000 $347,200 Full Funding Special Provision Bristol Bay 238 Pilot Point High Penetration Wind/Diesel/CHP City of Pilot Point Utility Local Government Wind 1.28 1.2 18 14 7 11 4 18 2 60 32 $1,798,360 $910,180 $45,280 $910,180 Full Funding Bering Straits 301 Stebbins Wind Analysis_AVEC Akaska Village Electric Cooperative (AVEC)Utility Wind 0.93 0.93 19 14 6 10 5 19 2 59 33 $5,750,000 $103,256 $5,435 $103,256 Full Funding Cost and RequestProjectStage 3 Review Scores (max)Benefit / Cost Fund Allocation by Development Stage Alaska Renewable Energy Fund Ranking and Proposed Grant Allocation Round 2 March 17, 2009 Page 2 of 4 Energy Region ID Project Name Applicant Applicant Type Project Type AEA Applicant 1. Cost of Energy (30) 2. Match (25) 3. Tech & Econ Feas (20) 4. Readiness (5) 5. Benefits (10) 6. Local Support (5) 7. Sustain- ability (5) Total (100) Statewide Rank Project Cost Grant Request Match Offered Cost and RequestProjectStage 3 Review Scores (max)Benefit / Cost Fund Allocation by Development Stage Southeast 206 Whitman Lake Hydro Construction_KPU Ketchikan Public Utilities Utility Local Government Hydro 7.9 9.15 4 17 8 20 5 4 0 58 34 $17,750,000 $12,020,000 $3,000,000 $12,020,000 Full Funding Railbelt 254 Victor Creek Hydro_Kenai Hydro Kenai Hydro, LLC IPP Hydro 2.94 2.94 5 17 8 18 4 5 2 58 35 $19,860,400 $88,320 $22,080 $88,320 Full Funding Special Provision Southeast 262 West Creek Hydro_Muni Skagway Borough and Municipality of Skagway Local Government Hydro 1.26 1.22 9 14 7 20 3 9 2 58 36 $140,000,000 $6,864,000 $1,716,000 $236,000 Partial Funding Special Provision Bristol Bay 300 New Stuyahok Wind Analysis_AVEC Alaska Village Cooperative (AVEC)Utility Wind 0.59 0.59 19 13 4 10 5 19 2 56 37 $4,436,800 $117,610 $6,190 $117,610 Full Funding Northwest Arctic 284 Kotzebue Solid Waste_City of Kotzebue Municipal Government Local Government Biofuels 14 12 4 19 2 14 0 56 38 $1,520,000 $15,000 $5,000 $15,000 Full Funding Special Provision Northwest Arctic 278 Solar Hot Water NWAB_NIHA Northwest Inupiat Housing Authority Government Entity Solar 18 11 3 10 4 18 4 55 39 $996,000 $986,000 $10,000 $101,000 Partial Funding Railbelt 310 ORPC Cook Inlet Tidal ORPC Alaska LLC ("ORPC")IPP Ocean/River 0.18 0.32 3 13 4 21 3 3 5 54 40 $7,858,177 $1,787,476 $640,825 $1,787,476 Full Funding Special Provision Southeast 276 Integrated Resource Plan_FDPPA The Four Dam Pool Power Agency Government Entity Other 4 15 5 18 5 4 2 54 41 $312,000 $252,000 $60,000 $252,000 Full Funding Special Provision Railbelt 282 Tidal Feasibility_City of Homer City of Homer Local Government Ocean/River 0.1 0.24 5 12 4 23 3 5 2 53 42 $2,498,591 $482,387 $672,125 $482,387 Full Funding Special Provision Copper River/Chugach 217 Camp Hill Wind_NVE Native Village of Eyak Other Wind 1.89 1.54 12 12 6 13 4 12 2 53 43 $8,945,073 $522,633 $29,440 $32,597 Partial Funding Lower Yukon-Kuskokwim 212 Akiachak Wind_ANCEC Akiachak Native Community Electric Company Utility Wind 23 7 3 16 2 23 0 52 44 $4,500,000 $4,500,000 $600,000 $15,000 Partial Funding Southeast 264 Yakutat Wave Energy Conversion Yakutat Power Utility Ocean/River 0.48 0.6 20 12 3 11 3 20 0 52 45 $6,944,000 $6,900,000 $44,000 $632,500 Partial Funding Special Provision Yukon- Koyukuk/Upper Tanana 260 Biomass Hydronic Heating_YKSD Yukon-Koyukuk School District Government Entity Biomass 0 0 19 10 3 11 3 19 2 51 46 $1,300,000 $288,500 $17,500 $16,550 Partial Funding Bering Straits 258 Pilgrim Hot Springs Assessment_ACEP University of Alaska Fairbanks, Institute of Northern Engineering, Alaska Center for Energy and Power Government Entity Geothermal 1.78 1.3 12 18 9 0 5 12 2 51 47 $2,349,751 $2,349,751 $2,349,751 Full Funding Aleutians 246 Hot Springs Bay Valley_Akutan City of Akutan Local Government Geothermal 3.19 3.19 12 17 9 0 4 12 4 50 48 $45,000,000 $2,995,000 $2,995,000 Full Funding Special Provision Southeast 209 Kasaan Wood Boiler_Village of Kasaan Organized Village of Kasaan Government Entity Biomass 0 0 10 12 5 12 4 10 2 50 49 $32,000 $30,000 $2,000 $30,000 Full Funding Copper River/Chugach 286 Slana Wind Construction_AWP Village Wind Power, LLC IPP Wind -0.63 4.83 28 11 3 0 4 28 2 49 50 $6,940,000 $6,940,000 $120,000 Partial Funding Aleutians 248 Loud Creek Hydro_Akutan City of Akutan Local Government Hydro 3.78 5.61 12 17 9 0 4 12 3 49 51 $237,772 $237,772 Full Funding Southeast 294 Sitka CHP_City and Borough City and Borough of Sitka (CBS) Alaska Local Government Biomass 4 14 8 12 4 4 2 48 52 $32,000 $30,000 $2,000 $30,000 Full Funding Yukon- Koyukuk/Upper Tanana 287 Tok Wind Construction_VWP Village Wind Power, LLC IPP Wind 3.11 3.36 18 14 8 0 4 18 2 48 53 $8,100,000 $8,100,000 $130,000 Partial Funding Bristol Bay 279 Tanalian River Hydro_AGE Alaska Green Energy, LLC IPP Hydro 1.03 1.03 26 9 5 0 2 26 5 47 54 $4,097,000 $4,097,000 $92,000 Partial Funding Special Provision Aleutians 249 Akutan Hydrosystem Repair and Upgrade City of Akutan Local Government Hydro 1.61 1.84 12 15 7 0 4 12 2 46 55 $1,795,450 $1,795,450 $162,000 Partial Funding Railbelt 213 Jack River Recon_Cantwell Native Village of Cantwell Government Entity Hydro 6 8 6 10 4 6 5 43 56 $200,000 $194,540 $5,460 $194,540 Full Funding Southeast 225 Triangle Lake_Metlakatla Indian Community Metlakatla Indian Community (MIC)Government Entity Hydro 5.49 6.03 3 15 8 0 5 3 2 37 57 $17,722,000 $500,000 $500,000 Full Funding Railbelt 289 Glacier Fork Hydro Glacier Fork Hydropower, LLC IPP Hydro 2.7 3.26 5 13 8 0 3 5 2 33 58 $330,000,000 $5,000,000 $500,000 Partial Funding Special Provision Railbelt 255 Chena Hot Springs Reservoir Modeling_ACEP University of Alaska Fairbanks, Institute of Northern Engineering, Alaska Center for Energy and Power Government Entity Geothermal 6 12 2 0 5 6 3 33 59 $198,168 $198,168 $198,168 Full Funding Bristol Bay 232 Bristol Bay Fish Waste_NEA Naknek Electric Association Utility Biofuels 9 11 4 4 9 30 60 $100,000 $75,000 $25,000 $75,000 Full Funding Lower Yukon- Kuskokwim 272 Akiak Wind Akiak Power Utilities Utility Wind $200,000 $200,000 Did Not Pass Stage 1 Lower Yukon- Kuskokwim 247 Bethel Wind Power x4_City of Bethel City of Bethel Local Government Wind $3,197,986 $2,598,320 $599,666 Lower Yukon- Kuskokwim 237 Kotlik Pellet Stove_KYE Kotlik Yupik Enterprise Government Entity IPP Biomass $626,400 $626,400 $50,000 Railbelt 201 Hydokinetic Resource Assessment_UAA University of Alaska Anchorage Government Entity Ocean/River $565,439 $565,439 Southeast 202 Ruth Lake Hydro Phase II _PMPL City of Petersburg, Alaska d/b/a Petersburg Municipal Power & Light Utility Local Government Hydro $109,975,000 $2,000,000 $520,000 Not Recommended Lower Yukon- Kuskokwim 203 Akiachak Wind_ANCEC Akiachak Native Community Electric Company Utility Wind $4,500,000 $4,500,000 $600,000 Alaska Renewable Energy Fund Ranking and Proposed Grant Allocation Round 2 March 17, 2009 Page 3 of 4 Energy Region ID Project Name Applicant Applicant Type Project Type AEA Applicant 1. Cost of Energy (30) 2. Match (25) 3. Tech & Econ Feas (20) 4. Readiness (5) 5. Benefits (10) 6. Local Support (5) 7. Sustain- ability (5) Total (100) Statewide Rank Project Cost Grant Request Match Offered Cost and RequestProjectStage 3 Review Scores (max)Benefit / Cost Fund Allocation by Development Stage Bristol Bay 204 Grant Lake Phase III & IV_Nushagak Nushagak Electric & Telephone Company, Inc Utility Hydro 0.6 0.64 $38,000,000 $20,000,000 $18,000,000 Not Recommended Copper River/Chugach 207 PetroStar HR_VFDA Valdez Fisheries Development Association IPP Heat Recovery $35,000,000 $6,000,000 $350,000 Not Recommended Southeast 208 Coffman Cove Wood Boiler_SEISD Southeast Island School District Government Entity Biomass $355,056 $341,056 $14,000 Southeast 214 Air Source Heat Pump_BIHA Baranof Island Housing Authority Government Entity Other $142,000 $121,000 $21,000 Did Not Pass Stage 1 Southeast 216 Little Port Walter Hydro_Ameresco Ameresco, Inc IPP Hydro $1,430,000 $50,000 $10,000 Lower Yukon-Kuskokwim 219 High Penetration Wind Diesel Heat_Kipnuk Kipnuk Light Plant Utility Wind 2.11 0.46 $10,188,000 $8,588,000 $1,600,000 Not Recommended Railbelt 220 Heat Recovery UMED_MLPUAA University of Alaska Anchorage (UAA) and Municipal Light & Power (ML&P)Utility Government Entity Heat Recovery $55,000,000 $35,000,000 $20,000,000 Southeast 221 Kake Biomass gasifer_ccthita Central Council Tlingit and Haida Indian Tribes of Alaska Local Government Biomass $5,000,000 $4,750,000 $250,000 Not Recommended Southeast 224 Haines Assistant living GSHP_Apt Alaska Power and Telephone, Inc. Haines Assistant Living, Inc.Utility Geothermal 0.58 0.58 $2,379,007 $1,432,906 $946,101 Not Recommended Southeast 227 AK_BC Intertie_Wrangell City and Borough of Wrangell Local Government Transmission $5,033,414 $4,433,414 $600,000 Not Recommended Southeast 228 Sunrise Lake Hydro_Wrangell City and Borough of Wrangell Local Government Hydro 1.43 0.74 $4,637,616 $4,367,616 Not Recommended Railbelt 229 AVTEC Wind Alaska Vocational Technical Center (AVTEC)Government Entity Wind -0.16 -0.15 $708,936 $634,968 $73,995 Not Recommended Railbelt 230 Wood Gasification_KISKIL Delta Mine Training Center, Inc.IPP Biomass $6,134,786 $2,034,217 $778,004 Did Not Pass Stage 1 Lower Yukon- Kuskokwim 233 Crooked Creek Hydro Kinetic Crooked Creek Traditional Council Government Entity Ocean/River $368,000 $368,000 Not Recommended Railbelt 234 Knik Arm CHC_KAPP KAPP,LLC IPP Biomass $40,000,000 $15,000,000 $25,000,000 Not Recommended Railbelt 239 Biomassheat Anchorage_Earth Run Energy EarthRun Energy IPP Biomass $42,000 $42,000 Not Recommended Southeast 240 Wasteoil for Heat_#2 Fuel Daniel A Pryse IPP Other $116,625 $116,625 Railbelt 241 Natural Gas Distribution_AGPA Alaska Gasline Port Authority Government Entity Gas $30,000 $30,000 North Slope 242 Wainwright Coal Bed Methane Phase III North Slope Borough Local Government Other $3,612,000 $3,300,000 $312,000 Yukon-Koyukuk/Upper Tanana 250 Galena Hydrokinetic City of Galena Local Government Ocean/River $279,331 $223,464 $55,866 Not Recommended Aleutians 251 AEB Geothermal Assessment_AGDAP Aleutians East Borough Local Government Geothermal $6,000,000 $4,336,950 $70,000 Not Recommended Yukon- Koyukuk/Upper Tanana 252 Manley Village Council Geothermal Manley Village Council Government Entity Geothermal $187,361 $144,107 $43,254 Not Recommended Railbelt 253 Chena Power Hydrogen Chena Power, LLC Utility Geothermal $2,482,803 $1,241,402 $1,241,402 Not Recommended Railbelt 256 Statewide Heat Pump Analysis_ACEP University of Alaska Fairbanks, Center for Energy and Power Government Entity Geothermal $95,984 $80,984 $15,000 Railbelt 257 Mt. Spur Resource Assessment_Ormat Ormat Nevada, Inc IPP Geothermal $15,700,582 $4,478,345 $20,178,927 Not Recommended Lower Yukon- Kuskokwim 259 Mountain Village Wind_City and Tribe Asa'carsarmuit Tribal Council Government Entity Wind $133,255 $122,100 $11,155 Not Recommended Yukon- Koyukuk/Upper Tanana 261 Alternative Energy Recon_YKSD Yukon-Koyukuk School District Government Entity Other $112,000 $8,500 Not Recommended Copper River/Chugach 263 Alternative Energy Feasibilty_CSD Chugach School District Government Entity Other $1,380,439 $1,380,439 Not Recommended Yukon- Koyukuk/Upper Tanana 266 Birch Creek Solar Birch Creek Village Council Government Entity Solar 0.59 0.4 $112,200 $89,600 $22,600 Not Recommended Southeast 267 Mobile Biodiesel Processing Plant_CCTHIA Tlingit Haida Central Council Government Entity Biofuels -0.72 19.73 $323,466 $1,500,000 $72,050 Not Recommended Railbelt 268 UAF Absorption Chiller University of Alaska, Fairbanks Government Entity Heat Recovery 0.43 0.43 $15,000,000 $10,000,000 $5,000,000 Not Recommended Southeast 269 WCA Hydrokinetic_Tanana River Whitestone Community Association Government Entity Ocean/River $3,965,660 $3,880,660 $85,000 Alaska Renewable Energy Fund Ranking and Proposed Grant Allocation Round 2 March 17, 2009 Page 4 of 4 Energy Region ID Project Name Applicant Applicant Type Project Type AEA Applicant 1. Cost of Energy (30) 2. Match (25) 3. Tech & Econ Feas (20) 4. Readiness (5) 5. Benefits (10) 6. Local Support (5) 7. Sustain- ability (5) Total (100) Statewide Rank Project Cost Grant Request Match Offered Cost and RequestProjectStage 3 Review Scores (max)Benefit / Cost Fund Allocation by Development Stage Railbelt 270 UAF Photovoltaic Univertity of Alaska, Fairbanks Government Entity Solar 0.19 0.19 $370,000 $320,000 $50,000 Not Recommended Copper River/Chugach 274 Wind Recon_NPRHA North Pacific Rim Housing Authority Government Entity Wind -0.58 3.93 $313,000 $30,500 $15,000 Not Recommended Railbelt 275 Nenana Healy Hydro Phase II_GVEA Golden Valley Electric Association Utility Hydro $24,000,000 $2,200,000 $550,000 Bristol Bay 280 Alternative Energy Assessment_Perryville NVOP Native Village of Perryville (NVOP)Government Entity Other 0.89 0.91 $95,581 $95,581 Not Recommended Yukon- Koyukuk/Upper Tanana 281 Tanana Alternative Energy Assessment _Tanana Power Tanana Power Company Utility Other $393,299 $303,060 $90,239 Not Recommended Railbelt 283 Statewide Biomass Assessment_UAF University of Alaska, Fairbanks Government Entity Biomass $454,828 $454,828 Railbelt 285 Delta Wind Construction_AWP Alaska Wind Power, LLC IPP Wind 1.92 2.3 $135,300,000 $13,000,000 $700,000 Not Recommended Aleutians 288 St Paul Wind Construction_City of St. Paul City of St. Paul Utility Local Government Wind 3.49 3.22 $1,760,000 $1,600,000 $160,000 Not Recommended Bristol Bay 290 Packers Creek Hydro_CLPU Chignik Lagoon Power Utility (CLPU)Utility Hydro $1,900,000 $1,750,000 Not Recommended Yukon- Koyukuk/Upper Tanana 291 McGrath District Heat_MPL McGrath Power and Light Utility IPP Biomass $1,590,092 $822,950 $767,142 Not Recommended Yukon- Koyukuk/Upper Tanana 292 Chalkyitsik District Heat_Village Council Chalkyitsik Village Council Local Government Biomass $1,540,023 $88,500 $20,000 Not Recommended Railbelt 295 Delia Creek Hydro_HPML HPML LLC IPP Hydro $1,550,000 $1,550,000 $50,000 Not Recommended Railbelt 296 Archangel Creek Hydro_AGP Archangel Green Power, LLC Utility IPP Hydro 2.92 3.45 $6,420,000 $100,000 $60,000 Not Recommended Railbelt 304 Geothermal Resource Assessment Seward Pen_AVEC Alaska Village Electric Cooperative (AVEC)Utility Geothermal $4,600,000 $4,301,950 $145,000 Not Recommended Railbelt 308 Plasma Gasification_Solena Group Solena Group IPP Biofuels $100,000,000 $300,000 $300,000 Lower Yukon- Kuskokwim 309 Orutsaramiut Native Council Orutsaramiut Native Council Incorporated Local Government Gas Yukon-Koyukuk/Upper Tanana 311 Tanana Biomass Feasibility Tanana Tribal Council Government Entity Biomass $39,869 $30,669 $9,200 Not Recommended Yukon- Koyukuk/Upper Tanana 312 Tanacross Biomass Feasibility Tanacross Tribal Council Government Entity Biomass $38,844 $29,644 $9,200 Not Recommended Yukon- Koyukuk/Upper Tanana 313 Nenana Biomass Feasibility Nanana Native Council Government Entity Biomass $38,265 $29,065 $9,200 Not Recommended Bristol Bay 318 Chignik Lake CBM_AGE Alaska Green Energy, LLC (AGE)IPP Biofuels $1,995,000 $1,995,000 Copper River/Chugach 319 Wood Pellet Plant_AHTNA Ahtna, Incorporated IPP Biomass $15,760,000 $8,630,000 $7,130,000 Not Recommended Lower Yukon- Kuskokwim 320 Marshall Wood Fired Boiler_Ohogamiut Traditional Council Ohogamiut Traditional Council Government Entity Biofuels $357,152 $339,452 $17,700 Did Not Pass Stage 1 Northwest Arctic 321 Noatak Biomass_Native Village of Noatak Native Village of Noatak Government Entity Biomass $50,000 $50,000 Did Not Pass Stage 1