Loading...
HomeMy WebLinkAboutBarter-Island-Kaktovik_longterm-dataBARTER ISLAND(AWOS) AK - 700865 70 deg 08' N 143 deg 35' W - Elev 2m LST=GMT+99 hours *NT=-10 01/74-07/74 05/91-10/96 Adjusted to Alaska Time Zone (GMT-9) SPEED BY YEAR Year ALL JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC ALL 5.1 5.82 6.18 5 3.78 4.4 3.95 4.32 4.37 5.77 5.91 6.07 6.15 1974 4.28 4.99 3.57 1.88 2.55 3.96 4.87 3.63 -1 -1 -1 -1 -1 1991 3.49 -1 -1 -1 -1 4.2 2.98 3.15 2.35 0 -1 -1 -1 1992 5.22 -1 -1 -1 -1 -1 -1 -1 4.34 5.21 5.96 4.85 5.21 1993 5.32 6.88 6.5 4.49 3.89 4.87 3.99 4.96 4.02 6.9 4.93 5.39 6.76 1994 5.25 6.61 9.87 5.09 3.18 4.44 3.64 3.97 4.71 6.31 5.02 8.31 4.34 1995 5.17 4.59 5.33 5.8 4.24 4.32 3.56 4.52 4.33 5.09 7.04 5.54 7.53 1996 4.55 5 6.23 4.9 3.73 4.1 4.31 4.16 4.6 4.85 4.94 -1 -1 POWER BY YEAR Year ALL JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC ALL 277 349 667 284 108 118 87 87 116 305 316 511 459 1974 137 224 97 39 47 65 144 53 -1 -1 -1 -1 -1 1991 58 -1 -1 -1 -1 100 26 24 9 0 -1 -1 -1 1992 262 -1 -1 -1 -1 -1 -1 -1 131 218 401 265 214 1993 321 501 622 197 119 195 110 135 89 541 170 308 709 1994 324 419 1855 274 63 105 61 68 169 338 180 1077 184 1995 252 146 377 409 144 91 54 92 83 207 388 336 668 1996 224 317 849 282 99 100 113 75 112 161 203 -1 -1 NUMBER OF SPEED OBSERVATIONS BY YEAR Year ALL JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC ALL 26779 2116 1981 2292 2439 2480 2377 1920 2378 2569 1877 2329 2021 1974 838 218 224 23 25 27 260 61 0 0 0 0 0 1991 90 0 0 0 0 40 36 11 2 1 0 0 0 1992 2849 0 0 0 0 0 0 0 286 639 666 636 622 1993 5737 613 610 666 637 486 316 323 628 500 66 486 406 1994 6425 467 234 379 495 676 656 673 656 655 583 627 324 1995 7027 431 574 568 650 600 546 621 650 621 517 580 669 1996 3813 387 339 656 632 651 563 231 156 153 45 0 0 NUMBER OF SPEED OBSERVATIONS BY HOUR Hour ALL JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC 0 1115 81 72 96 107 104 95 80 105 111 77 103 84 1 1122 86 77 98 102 109 91 78 103 107 84 97 90 2 1098 80 76 91 104 110 81 81 102 112 76 98 87 3 1112 74 74 100 100 106 92 81 99 113 82 100 91 4 1053 76 70 91 95 104 93 78 93 91 84 103 75 5 1113 77 74 98 101 108 96 81 103 108 85 100 82 6 1115 89 80 95 103 104 90 79 101 104 80 101 89 7 1144 93 96 98 98 100 112 84 94 108 75 99 87 8 1161 106 93 94 105 99 112 87 93 102 84 104 82 9 1162 100 93 96 100 103 116 83 99 109 83 94 86 10 1039 90 87 90 92 91 108 71 88 94 69 81 78 11 1127 97 94 90 102 106 111 82 89 105 79 92 80 12 1153 93 95 94 102 104 115 83 98 112 78 96 83 13 1118 95 84 95 100 106 111 78 96 111 70 94 78 14 1142 101 94 107 97 105 110 83 96 102 73 92 82 15 1136 96 90 98 98 100 109 84 102 109 76 89 85 16 1077 100 93 90 91 94 114 71 89 91 72 92 80 17 1214 99 96 110 118 130 112 82 98 106 76 97 90 18 1079 76 74 83 103 98 82 85 106 112 83 94 83 19 1084 78 73 96 97 100 83 79 102 113 77 105 81 20 1103 84 78 99 108 96 87 76 105 110 74 102 84 21 1092 81 71 97 107 102 86 75 103 110 76 96 88 22 1099 81 75 93 102 100 87 78 104 109 82 101 87 23 1121 83 72 93 107 101 84 81 110 120 82 99 89 SPEED BY HOUR Hour ALL JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC 0 5.05 6.01 6.81 5.01 3.87 4.2 3.51 3.97 4.04 5.66 6.21 6.17 5.99 1 5.09 5.63 6.75 5.07 3.65 4.15 3.63 4.01 4.25 5.71 6.16 6.36 6.27 2 5.12 5.71 6.7 5 3.77 4.02 3.77 4.06 4.53 5.71 6.19 6.29 6.31 3 5.08 5.61 6.51 5.05 3.89 4.04 3.5 4.07 4.35 5.97 6.1 6.05 6.26 4 5.03 5.64 6.72 5.13 3.71 4.14 3.63 4.25 4.11 5.48 5.74 6.06 6.59 5 5 5.32 6.48 4.96 3.38 4.15 3.48 4.36 4.24 6 5.96 6.44 5.86 6 5.1 5.65 6.43 5.19 3.51 4.02 3.34 4.31 4.38 6.04 6.14 6.46 6.1 7 4.97 5.18 5.74 5.04 3.63 4.13 3.45 3.97 3.97 6.09 6.07 6.51 6.24 8 5.05 5.79 5.67 5.13 3.51 4.29 3.65 4.25 4.12 5.84 6.01 6.43 6.28 9 5.02 5.89 5.64 5.1 3.79 4.3 3.69 3.87 4.4 6.06 5.87 5.94 6.04 10 5.04 5.36 6.13 4.99 3.7 4.53 3.81 4.15 4.52 5.78 5.83 6.07 6.12 11 5.2 6.06 6.02 5.27 3.97 4.47 4.14 4.58 4.33 6.07 5.69 6.11 6.03 12 5.15 5.72 5.74 5.39 3.92 4.64 4.22 4.85 4.18 5.94 5.45 5.88 6.28 13 5.1 5.58 5.42 5.19 3.91 4.79 4.5 4.5 4.44 6.2 5.49 5.74 5.64 14 5.22 5.84 5.7 5.34 4.1 4.79 4.46 4.48 4.61 6.11 5.72 5.83 5.92 15 5.21 5.81 5.9 5.44 3.77 4.88 4.56 4.38 4.55 5.58 6.28 5.43 6.32 16 5.15 6.09 5.51 5.06 3.87 4.68 4.57 4.23 4.95 5.38 5.68 5.85 5.99 17 5.03 5.68 5.77 4.23 3.74 4.62 4.53 4.57 4.69 5.35 6.05 5.97 5.97 18 5.17 5.89 6.2 4.67 3.99 4.7 4.27 4.8 4.79 5.33 5.58 6.12 6.22 19 5.16 6.44 6.53 4.46 3.7 4.48 4.07 4.86 4.52 5.3 5.73 6.11 6.39 20 5.13 6.27 6.63 4.73 3.69 4.48 4.23 4.61 4.34 5.7 5.79 5.82 5.91 21 5.17 6.24 6.98 4.7 4 4.34 3.97 4.35 4.29 5.66 6.07 5.82 6.45 22 5.2 6.17 6.89 5.08 3.9 4.35 3.73 4.18 4.25 5.85 5.93 6.25 6.32 23 5.04 6.16 6.62 4.94 3.83 4.38 3.74 4.02 4.06 5.56 5.96 5.74 6.1 POWER BY HOUR Hour ALL JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC 0 259 312 629 317 115 101 73 65 83 285 328 543 382 1 273 268 747 301 95 105 66 71 102 325 332 522 443 2 281 283 773 284 100 104 87 84 120 325 331 536 452 3 274 277 662 308 106 98 64 80 113 364 307 501 484 4 270 304 670 345 115 103 61 92 88 266 250 537 535 5 273 244 637 332 89 107 68 90 109 377 316 592 413 6 287 286 627 340 88 93 85 103 120 323 328 636 464 7 271 239 439 283 94 112 82 78 92 340 354 678 493 8 281 378 527 277 93 108 75 91 113 324 339 609 477 9 266 387 538 307 120 114 64 73 134 349 305 472 378 10 271 328 648 233 123 124 71 73 139 297 291 546 451 11 284 390 643 293 125 119 89 87 131 332 252 515 493 12 282 330 721 293 128 129 101 106 121 308 270 459 479 13 265 326 534 376 104 158 114 82 105 334 292 433 392 14 280 386 614 345 133 137 110 85 123 306 285 460 414 15 283 400 622 313 113 162 108 88 125 277 390 388 499 16 278 437 633 290 117 142 110 80 150 249 306 421 399 17 268 410 635 245 96 130 106 97 142 251 344 469 401 18 278 379 653 269 108 154 100 115 166 240 273 508 509 19 306 487 971 261 112 106 102 112 127 241 350 469 533 20 283 405 866 217 98 108 102 103 110 311 346 485 368 21 292 389 953 173 121 100 86 89 96 312 359 462 574 22 283 332 823 206 113 104 76 76 100 329 322 530 499 23 259 334 773 221 103 106 77 66 87 259 319 451 476 SPEED BY DIRECTION Month calm 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360 ALL 0 2.76 3.14 3.87 4.21 5.34 5.03 5.45 4.89 5.68 5.31 6.9 5.14 4.32 3.74 3.2 3.47 3.33 3.25 3.29 3.37 3.56 3.49 4 5.25 6.55 5.77 5.13 6.31 8 7.35 5.48 4.67 3.48 3.34 2.96 2.66 2.76 1 0 3 2.9 4 3.6 4.1 4.1 4.6 3.4 5.9 6.2 7.8 5.8 5.5 3.3 2.8 3.7 3.1 3.4 3.8 3.9 4 4.1 5.5 7.2 8.1 7.3 5.3 5.7 7.1 8.5 7.8 3.7 3.8 3.6 2.5 3.9 3 2 0 2.8 1.8 5.1 5.1 7.8 8.9 6.9 3.7 4.6 5.1 4.9 3.3 3.6 3.5 2.9 2.1 2.7 2.7 2.4 4.4 4.1 3.9 4.6 5.2 7.4 6.9 5.1 8 12.3 11.3 9.6 6.7 4.5 3.6 2.7 2.9 2.8 3 0 2.3 2.9 3.4 3.4 4.5 4.2 5 4.3 4.5 4.6 5.1 4.2 3.5 3.5 2.6 3 2.2 2.4 2.8 2.6 2.8 2.9 3.6 3.9 5.8 5.1 4.2 5.5 8.5 9.7 6.9 4 3 2.2 3.5 2.2 2.3 4 0 1.7 2.1 3.2 3.8 6.1 4.9 4.1 4.4 5.7 4.9 6.6 4.5 3.4 2.7 2.4 2.9 2.3 2.5 2.6 2.7 2.9 2.6 2.2 3.2 3.6 3 3.4 4 4.9 4.2 3.3 2.6 2.4 3 2 1.9 1.7 5 0 2.4 2.3 3.1 3.9 4.5 5.7 5.9 4.8 4.7 4.2 5.7 5.5 4.7 3.8 4.3 3.2 2.3 2.6 2.7 2.2 3 3.2 2.7 2.4 3.9 4.4 3.7 4.3 5.9 5.2 4.7 4.5 4.3 2.9 2.4 2.1 2.4 6 0 2.4 2.7 2.8 3.3 4.4 5 4.9 4.2 4.7 4.2 5.9 4.6 3.6 4.3 3.8 3.6 2.2 2.4 3.7 2.7 3.5 2.3 6.4 4.7 5 4.3 4.3 5 4.9 4.5 4.5 4.2 2.7 2.5 2.4 2.3 2.4 7 0 2.5 3.6 3.8 3.8 4 3.8 4.8 4.7 4.9 4.9 6.2 4.4 4.3 4.3 3.9 4.3 3.1 5.2 3.1 3.6 3.3 3.2 4.3 4.4 4.6 5.2 5 4.8 4.9 4.4 4.4 3.7 3 3.3 3.4 2.8 2.5 8 0 3 4 4.2 3.2 4.3 3.6 6.2 5 4.3 4.3 6.3 5.6 4.4 4.3 3.8 3.7 3.8 3.6 3.8 3.1 3.6 3.9 4.7 3.9 4.6 4.9 4.9 5 5 5 5 5.2 4 3.6 3.2 2.7 3 9 0 3.1 3.8 4.7 5.2 4.9 5.1 6 6 6.9 6.5 7.8 5.4 4.1 3.9 3.3 3.9 4.6 3.2 3.7 3.6 3.4 3.4 4.1 6.2 7.8 5.4 7.2 8.8 7.9 6.1 4.9 5.4 4.2 4.1 3.4 3.2 3.1 10 0 3.5 3.6 4.4 5.7 7.3 4.4 5.8 6.2 6.8 6.4 8.5 6.6 7.1 3.8 2.7 3.5 3.9 3.7 2.9 2.9 3.7 3.7 4.1 8 7.1 6.2 5 6.2 6.8 7 5.6 5.6 3.8 3.9 3.6 3.2 3.5 11 0 3.8 3.7 4.3 3.7 4.4 7.9 5.9 5.4 5.5 5.6 8.1 5.2 3.9 3.9 3.2 2.8 3 3.1 3 3 3.4 3 3.4 3.7 6.7 5.6 7.4 8.3 11.9 10.5 7.8 5.2 4 4.8 3.9 3.3 3.8 12 0 2.8 3.2 4.7 6.3 7.2 4.4 4.5 5.7 8.5 7.2 9.8 5.7 3.4 3.5 2.8 2 2.2 4.3 3 3.3 3.5 3.6 3.8 4.6 6.6 5.8 5.3 7.6 9.7 8.9 7.4 5.2 6.3 3.3 2.9 3.4 2.8 FREQUENCY BY DIRECTION Month calm 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360 ALL 8.23 0.68 0.96 1.49 2.21 3.23 4.03 4.76 4.53 6.39 8.04 7.94 2.77 1.55 0.87 0.74 0.71 0.54 0.52 0.59 0.8 1.35 1.25 1.52 2.4 5.46 4.45 3.56 4.66 8.07 6.07 2.78 1.46 1.18 0.92 0.74 0.77 0.68 1 8.5 0.4 0.2 0.7 0.5 0.6 0.8 1.2 1.1 4.3 7.6 8.2 2.9 2 1 1.2 1.5 0.4 0.7 1.2 0.9 1.9 1.5 2 3.9 11.1 11.3 6.4 6.2 7.5 6.8 1.6 0.5 0.6 0.5 0.7 0.2 0.4 2 10.4 0.1 0.2 1 1.8 2.4 2.4 4.8 3.8 3.4 4.9 3.9 2.4 1.4 1 0.7 0.5 0.2 0.6 0.5 1.6 2.9 2.3 2 3.8 7.7 7.8 6.5 7.2 13.4 5.3 1 0.8 0.4 0.6 0.6 0.3 0.1 3 8.5 0.6 0.9 0.7 1.2 2.1 2.1 2.7 2.5 4.1 7 8.5 3.1 1.2 0.8 0.6 0.3 0.3 0.2 0.3 0.5 1.2 1.2 2 3.3 10.5 6.9 5.2 5.2 10.7 8.3 2.9 1.3 1 0.1 0.2 0.4 0.6 4 14.3 0.2 0.8 1.3 2.9 6.1 6.2 4.7 4.6 5 8.8 7.6 3.3 1.1 0.6 0.3 0.4 0.4 0.2 0.4 0.5 0.7 0.6 1.5 2.5 5.2 3.8 4.8 7.8 11.1 3.3 0.8 0.4 0.6 0.5 0.4 0.3 0.2 5 7.7 1.1 1.4 2.1 3 4.9 7.5 8.6 7.3 8.6 9.7 10.6 3 1.8 0.5 0.4 0.2 0.1 0.2 0.1 0.3 0.3 0.1 0.3 0.5 0.9 1.6 1.5 2.5 5.2 5.9 3.9 1.9 1.1 0.9 0.7 1.1 1.1 6 7.5 1.7 1.9 2.3 4 4 7.5 6.6 6.5 10.4 8.3 6.8 2 1 0.6 0.5 0.4 0.3 0.6 0.4 0.3 0.5 0.3 0.1 0.5 0.9 1 1.3 1.5 4.9 6.1 5 3 3.3 2.4 1.5 1.8 1.7 7 4.4 0.8 1.7 2.1 3.1 3.9 6.1 7.5 7.6 10.8 12.2 6.9 1.9 1.1 0.5 0.3 0.6 0.2 0.2 0.3 0.4 0.3 0.4 0.3 0.4 1.4 2.3 1.3 2.8 3.8 5.2 5.2 2.2 2 1.6 1.4 1.3 0.8 8 7.4 0.9 1.1 1.4 1.8 3.3 4.9 7.2 4.6 4.9 6.6 8.5 3.1 1.3 0.7 1.1 0.9 1.1 0.7 0.8 0.9 1.1 1.3 1.9 2 2.3 3.3 2.6 3.7 6.2 6.6 4 2.9 2 1.7 1.2 1.4 0.9 9 6.4 0.7 1.1 1.7 2 2.4 1.9 3.2 4.1 4.8 7.7 9.5 2.4 1.5 1.5 0.9 1.6 1 0.8 0.8 1.2 1.5 1.3 1.7 2.3 5.5 2.7 4.4 6.7 8.5 5.3 3 1.6 1.4 1.2 1.1 0.8 0.7 10 5.5 0.6 0.4 1.6 1.6 3.1 2.8 3.6 5.2 6.9 7.4 8.8 3.9 1.5 0.9 0.9 0.8 0.7 0.6 0.6 0.9 1.1 1.2 2.1 4.8 7.3 5 4.5 5.1 7.8 4.3 1.6 1 0.4 0.3 0.4 0.5 0.6 11 9.5 0.7 1 1.3 1.5 1.6 2.4 2.8 2.5 2.1 5.9 8.4 3.5 3.5 1.5 1.2 1.1 1.1 0.8 0.9 0.9 2.2 1.9 2.1 3.1 8.2 4.8 2.9 4.5 10.4 9.2 2.6 0.9 0.9 0.5 0.4 0.6 0.7 12 7.7 0.1 0.6 1.5 2.9 4.2 3 3.5 4.4 11.8 10.5 6.2 1.7 1.2 0.8 0.7 0.2 0.5 0.5 0.9 1.2 2.9 3.4 2.5 2.5 6.1 4.3 2 3.1 7.9 6.2 1 0.6 0.1 0.3 0.3 0.3 0.1 FREQUENCY OF SPEED Month 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 ALL 8.2 5.1 13.2 15.1 14.5 11.8 9 6.3 4.3 3.1 2.4 1.8 1.2 0.9 0.7 0.6 0.5 0.2 0.3 0.3 0.2 0.2 0.1 0 0 0 1 8.5 4.3 9.9 10.9 11 10.1 9.8 10.3 6.7 5.5 3.1 3 1.9 1.6 1 0.7 0.5 0.3 0.1 0.4 0.3 0 0 0 0 0 2 10.4 5.7 13.2 13.5 10.9 9.4 7.5 5.9 3.1 3.2 2.4 1.1 1 1.1 1.2 1.5 1.7 0.5 1.5 1 0.7 0.7 1.2 0.3 0.6 0.1 3 8.5 5.1 14.1 16.2 16.2 11.3 7 5.6 3.9 2.5 2.2 1.6 1.1 1 0.8 0.5 0.8 0.2 0.3 0.4 0.2 0.2 0 0.1 0 0 4 14.3 7.6 16.6 17.6 14.8 10.7 6.7 3.9 2.6 1.5 1.5 1 0.7 0.2 0.2 0.1 0 0 0 0 0 0 0 0 0 0 5 7.7 6.1 14.8 14 15 14.6 13.3 7.2 3.5 1.9 0.8 0.4 0.3 0.1 0.1 0 0.1 0 0 0 0 0 0 0 0 0 6 7.5 7 18.5 18.6 17.8 12.5 8 4.1 2.4 1.3 1.1 0.6 0.3 0.1 0.1 0 0 0 0 0 0 0 0 0 0 0 7 4.4 3.7 13 21.5 20.1 16.5 10.5 6 2 1.4 0.7 0.3 0 0 0 0 0 0 0 0 0 0 0 0 0 0 8 7.4 4.9 14.6 17.3 17.1 14.8 10.1 5.8 3.6 1.4 1 0.5 0.7 0.3 0.1 0.1 0 0 0 0 0 0 0 0 0 0 9 6.4 3.9 11 13.1 12.1 10.6 9.8 8.2 7.1 4.9 4 2.5 1.5 1.3 0.9 0.9 0.8 0.4 0.5 0 0 0 0 0 0 0 10 5.5 4 9.8 11.6 13.1 10.4 10.7 8.7 8.1 5.6 4.7 2.5 1.4 1.1 0.7 0.5 0.5 0.1 0.4 0.4 0.2 0.1 0 0 0 0 11 9.5 4.9 11.6 13.8 11.6 9.3 6.4 4.7 3.3 3.9 4.2 4 3.3 1.8 2.1 1.2 1.1 0.6 0.6 0.7 0.4 0.5 0.3 0.1 0 0 12 7.7 3.4 9.9 12.2 14.1 11.1 7.6 5.8 5.1 4.6 3.9 3.7 2.4 2.5 1.7 1.5 1.2 0.1 0.2 0.4 0.1 0.6 0 0 0 0 PERCENT OF POWER BY SPEED Month 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 ALL 0 0 0.4 1.3 2.9 4.3 5.5 6.3 6.2 6.3 6.8 6.6 5.9 5.5 5.5 5.5 6.1 2.4 4.4 4.5 3.2 3.7 3.3 1.4 1.7 0.3 1 0 0 0.2 0.8 1.8 3.1 5 8.7 8.2 9.1 7 8.9 7.3 7.6 6.1 5.4 4.3 3.5 1.7 5.3 4.7 0 1 0 0 0 2 0 0 0.2 0.5 0.9 1.5 2 2.5 2 2.7 2.9 1.7 2 2.7 4 5.9 8.2 2.7 9.7 7.2 6.1 6.6 13.9 3.8 8.8 1.6 3 0 0 0.4 1.5 3.3 4.3 4.4 5.8 5.8 5.2 6 6.1 5.3 6.4 6.2 4.9 9.1 2.2 5.2 6.7 3.6 3.8 0 3.7 0 0 4 0 0.2 1.3 4.1 7.7 10.3 10.6 9.9 10 8.1 10.8 9.7 8.1 3 3.1 3.1 0 0 0 0 0 0 0 0 0 0 5 0 0.1 1 2.8 7 12.5 19.1 16.5 11.6 9 5.5 3.8 3.1 1.7 2.2 0.9 2.1 1.2 0 0 0 0 0 0 0 0 6 0 0.2 1.6 5 10.6 13.6 14.4 12.1 10.5 7.9 9 6.8 4.8 1.6 2 0 0 0 0 0 0 0 0 0 0 0 7 0 0.1 1.2 5.9 11.9 18.1 19.2 17.5 8.5 8.3 5.6 3.6 0 0 0 0 0 0 0 0 0 0 0 0 0 0 8 0 0.1 1 3.4 7.7 12.5 14.2 12.9 11.8 6.7 6.5 4.5 7.7 3.9 2.3 1.7 0 1.2 0 0 1.8 0 0 0 0 0 9 0 0 0.3 1 2.1 3.4 5.3 7.1 9 8.8 9.8 8.2 6.2 6.7 5.7 7.5 7.6 3.9 5.9 0.6 0.7 0 0 0 0 0 10 0 0 0.3 0.9 2.3 3.3 5.8 7.5 10.2 9.8 11.2 8 5.8 5.8 4.5 4.2 5.1 0.6 5.5 5.6 2.8 1 0 0 0 0 11 0 0 0.2 0.7 1.3 1.9 2.2 2.6 2.6 4.3 6.6 8.2 8.9 6.2 8.5 6.3 6.6 4.2 4.5 6.9 4.3 6.7 3.6 1.9 0.8 0 12 0 0 0.2 0.7 1.8 2.6 3 3.6 4.6 6 6.8 8.7 7.4 9.6 8.1 8.9 8.6 1.2 1.8 4.1 1.9 8.6 0.8 0.9 0 0 PREVAILING DIRECTION BY HOUR Month 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 ALL 100 90 280 280 280 280 280 280 280 280 280 100 280 90 90 100 90 90 90 100 100 100 100 90 1 240 240 250 250 250 100 250 250 250 90 250 250 250 240 240 240 240 240 250 100 240 100 280 100 2 280 280 280 280 280 280 280 280 250 280 280 280 240 250 260 250 280 280 280 280 280 280 280 280 3 100 240 240 280 240 240 280 280 280 240 280 240 280 280 290 280 100 290 90 100 100 100 100 240 4 280 90 280 280 100 280 260 270 90 260 270 280 280 280 280 90 90 90 90 280 90 280 280 280 5 100 90 80 90 90 280 100 100 100 100 100 90 100 80 100 50 50 100 60 90 90 90 90 100 6 90 100 280 280 80 100 90 100 90 60 290 60 70 80 80 80 50 50 90 80 50 60 80 70 7 80 80 80 80 70 90 100 90 90 90 90 60 80 90 70 90 80 60 60 90 90 80 90 90 8 90 90 60 100 240 280 60 280 280 70 290 100 60 90 50 50 90 90 100 100 100 100 100 90 9 100 270 100 270 270 280 90 280 280 280 100 100 280 90 90 100 90 100 90 100 100 90 100 90 10 100 100 100 280 240 100 280 100 90 100 90 90 280 80 80 240 80 250 250 100 100 80 90 100 11 280 100 280 280 280 280 100 290 290 100 280 290 290 90 280 240 240 240 280 290 280 240 100 100 12 90 90 80 80 80 80 80 80 80 90 80 80 80 80 80 80 90 80 90 80 80 90 90 90 SPEED FOR PREVAILING DIRECTION BY HOUR Month 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 ALL 6.65 4.73 7.25 7.6 9.02 8.01 7.97 7.49 8.04 8.44 7 7.42 7.85 5.56 5.45 7.27 5.48 5.39 5.11 7.17 6.79 7.46 7.02 5.14 1 6.21 6.59 7.04 7.21 5.97 6.91 6.66 7.17 7.1 5.94 7.09 7.05 7.03 7.41 9.22 10.21 8.42 9.25 6.93 8.62 9.17 9.49 6.19 7.87 2 13.85 9.99 11.51 11.36 12.62 15.76 13 8.88 5.67 10.51 11.96 13.9 8.12 5.2 6.23 5.69 9.57 9.78 12.42 13.98 13.14 12.94 12.35 14.21 3 4.03 6.41 5.37 6.46 6.5 4.9 8.27 9.36 7.64 4.91 6.64 5.09 8 9.17 10.53 8.62 5.54 7.03 4.19 5.32 5.94 5.57 4.71 7.03 4 5.33 3.59 4.52 4.8 5.51 5.11 2.91 4.06 5.77 2.88 4.69 4.56 4.59 4.81 5.27 3.72 5.32 5.1 5.07 4.38 3.73 4.2 5.09 5.12 5 5.39 4.18 4.2 4.81 4.82 4.55 5.11 5.85 6.2 6.17 5.32 4.2 5.61 4.12 6.29 4.62 5.64 5.14 5.95 3.86 4.51 4.15 4 5.41 6 3.5 4.26 3.61 4.08 3.75 4.89 3.92 5.97 4.71 4.64 5.21 5.28 3.56 4.99 4.99 5.84 5.61 5.31 4.41 4.32 4.69 3.69 4.25 4.12 7 4.5 5.04 4.82 4.49 3.77 5.91 6.71 5.54 5.05 4.28 5.21 4.45 5.27 4.54 4.93 4.74 4.75 4.95 6.4 4.62 4.17 5.57 4.45 4.62 8 4.37 3.16 5.67 6.13 3.86 4.72 6.84 5.7 5.21 5.03 5.11 6.64 5.56 5.04 3.51 4.42 4.8 4.45 6.24 6.61 5.8 5.48 6.45 4.49 9 8.61 10.2 8.37 8.67 8.11 7.77 6.71 8.09 9.4 10.08 7.1 6.88 7.87 6.29 6.75 7.72 6.04 7.77 5.59 6.96 7.59 6.4 7.17 6.17 10 7.82 8.69 9.82 6.31 8.06 7.77 5.56 8.5 6.31 7.61 7.01 5.91 4.76 7.04 6 7.73 6.58 6.32 6.63 8.24 7.46 5.62 5.22 8.22 11 12.99 7.77 11.35 11.13 12.76 12.15 6.52 11.01 10.92 7.4 11.49 9.68 8.57 6.17 11.59 5.15 6.45 5.92 11.43 10.89 10.57 5.46 8.08 6.08 12 7.01 7.21 7.15 7.52 8.05 8.25 9.37 9.1 9.48 7.36 8.66 10.2 7.73 8.03 9.96 8.92 7.44 7.89 6.84 7.73 7.57 6.87 9.09 6.28