Loading...
HomeMy WebLinkAboutCape-Decision_longterm-dataCAPE DECISION(AMOS) AK - 703880 56 deg 00' N 134 deg 08' W - Elev 12m LST=GMT+99 hours *NT= -9 01/73-11/74 02/85-10/89 12/00-09/01 SPEED BY YEAR Year ALL JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC ALL 4.9 6.44 5.34 5 5.16 4.71 4.35 3.87 3.89 3.99 4.87 5.63 6.09 1973 6.04 7.3 5.95 4.91 7.36 6.22 5.73 4.51 5.31 4.54 7.05 6.6 7.48 1974 5.44 5.85 8.21 5.12 5.22 5.49 4.94 5 3.89 4.12 -1 4.1 -1 1985 4.7 -1 6.75 5.29 5.75 5.05 4.93 3.71 4.2 4.18 4.49 3.4 5.11 1986 4.68 7.01 4.33 5.68 4.75 3.82 4.01 4.3 3.1 3.3 4.09 5.44 5.54 1987 5.17 6.08 6.02 4.05 5.69 5.59 3.94 4.15 4.15 3.8 4.77 6.35 7.3 1988 4.72 5.22 5.95 6.02 4.97 3.94 3.34 3.07 3.41 3.96 4.72 6.82 5.63 1989 4.18 7.31 2.63 4.02 3.35 3.85 4.53 3.23 3.68 4.17 5.63 -1 -1 2000 4.6 -1 -1 -1 -1 -1 -1 -1 -1 -1 -1 -1 4.6 2001 13 -1 -1 -1 -1 -1 -1 -1 -1 13 -1 -1 -1 POWER BY YEAR Year ALL JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC ALL 224 482 293 217 233 167 119 80 87 106 233 383 388 1973 339 572 411 205 480 306 226 97 198 143 479 470 545 1974 265 382 611 266 188 221 171 210 98 103 -1 44 -1 1985 182 -1 416 229 308 203 150 77 103 136 181 136 204 1986 187 486 152 265 195 88 89 100 47 54 107 303 270 1987 234 325 351 138 286 231 81 78 99 84 196 363 557 1988 239 331 330 289 206 112 60 42 49 111 246 701 440 1989 182 798 53 153 55 93 132 43 62 107 455 -1 -1 2000 57 -1 -1 -1 -1 -1 -1 -1 -1 -1 -1 -1 57 2001 1317 -1 -1 -1 -1 -1 -1 -1 -1 1317 -1 -1 -1 NUMBER OF SPEED OBSERVATIONS BY YEAR Year ALL JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC ALL 42917 3487 3354 3983 3867 4009 3799 3993 3896 3417 3168 2853 3091 1973 4430 369 377 370 361 355 344 433 402 371 344 321 383 1974 2595 359 297 317 357 348 302 251 277 86 0 1 0 1985 6858 0 286 614 626 721 642 701 648 650 656 623 691 1986 7493 698 612 672 584 632 574 652 618 486 634 647 684 1987 7834 691 586 688 673 645 643 676 674 558 659 659 682 1988 7795 694 595 660 617 668 662 684 671 628 664 602 650 1989 5910 676 601 662 649 640 632 596 606 637 211 0 0 2000 1 0 0 0 0 0 0 0 0 0 0 0 1 2001 1 0 0 0 0 0 0 0 0 1 0 0 0 NUMBER OF SPEED OBSERVATIONS BY HOUR Hour ALL JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC 0 1533 116 114 145 133 147 128 145 138 127 120 104 116 1 1517 117 126 145 129 137 139 142 125 114 114 107 122 2 1795 151 139 177 160 156 161 174 161 136 139 116 125 3 1985 169 167 188 191 198 178 164 169 145 142 131 143 4 1766 143 144 163 166 171 157 177 147 133 124 110 131 5 1865 158 149 173 164 178 175 168 176 146 132 113 133 6 1868 150 148 176 177 181 174 172 168 143 130 115 134 7 1883 150 143 179 172 176 171 187 181 146 133 118 127 8 1834 147 142 165 166 178 154 175 169 162 136 115 125 9 2007 169 157 192 189 179 180 178 193 153 145 131 141 10 1839 151 145 174 159 177 170 172 174 151 128 114 124 11 1860 153 144 170 161 172 167 183 180 139 139 125 127 12 1898 152 138 172 169 174 172 172 178 162 146 128 135 13 1879 147 144 170 176 179 167 177 180 149 136 123 131 14 1780 144 136 165 161 147 148 167 173 154 133 122 130 15 1875 169 143 177 170 168 161 167 162 152 142 127 137 16 1523 111 106 136 136 143 133 141 135 134 122 114 112 17 1869 161 148 166 170 179 167 174 164 156 136 119 129 18 1568 117 112 142 135 144 136 144 152 129 126 114 117 19 1522 118 120 137 135 139 128 144 137 120 116 109 119 20 1895 156 154 173 162 173 170 184 168 155 136 126 138 21 2021 172 168 200 183 198 168 170 179 150 148 139 146 22 1491 114 122 141 136 140 124 144 125 116 108 106 115 23 1844 152 145 157 167 175 171 172 162 145 137 127 134 24 1533 116 114 145 133 147 128 145 138 127 120 104 116 SPEED BY HOUR Hour ALL JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC 0 4.63 6.46 5.18 4.77 4.42 4.18 4 3.38 3.48 3.83 4.81 5.76 6.25 1 4.56 6.36 5.05 4.65 4.39 3.96 3.89 3.25 3.53 3.64 5.01 5.34 6.16 2 4.66 6.4 5.54 4.9 4.67 4.16 4.23 3.3 3.43 3.8 4.7 5.68 5.79 3 4.82 6.31 5.96 5.28 4.9 4.35 3.85 3.17 3.7 3.74 5.17 5.7 6.07 4 4.72 6.53 5.71 5.13 5.01 4.16 3.75 3.01 3.33 3.89 4.76 6.15 6.15 5 4.64 6.39 5.41 5.07 5.14 3.99 3.66 3.08 3.18 3.81 4.95 5.84 6.21 6 4.66 6.48 5.21 4.85 5.01 4.37 3.86 3.09 3.47 3.82 4.79 5.82 5.99 7 4.77 6.53 5.41 4.93 5.38 4.63 4.08 3.38 3.32 3.82 4.69 5.93 6.29 8 4.81 6.61 5.22 5.15 5.35 4.98 3.91 3.46 3.55 3.77 4.89 5.61 6.06 9 4.99 6.48 5.65 5.15 5.49 5.15 4.28 3.7 3.66 3.88 5.2 5.52 6.21 10 5.02 6.37 5.62 5.07 5.56 5.05 4.31 4.01 3.84 4.21 4.96 6.02 5.97 11 5.02 6.34 5.29 5.34 5.52 5.13 4.6 4.01 3.81 4.23 4.96 5.53 6.01 12 5.12 6.34 5.34 5.36 5.74 5.1 4.73 4.4 4.18 4.17 4.75 5.42 6.41 13 5.22 7.04 5.03 5.19 5.72 5.31 4.94 4.37 4.35 4.4 5.31 5.62 5.74 14 5.26 6.48 5.43 5.42 5.75 5.42 5.02 4.46 4.51 4.47 4.94 5.43 6.17 15 5.3 6.41 5.23 5.08 5.75 5.53 4.9 4.84 4.82 4.43 5.11 5.46 6.04 16 5.01 6.36 4.84 5.22 5.04 4.97 4.9 4.77 4.56 4.09 4.59 5.42 5.76 17 5.19 6.55 5.19 5.22 5.39 5.03 5.01 4.91 4.61 4.26 4.73 5.48 6.05 18 4.91 6.43 4.92 4.74 4.97 4.74 4.59 4.51 4.35 4.35 4.4 5.36 6.12 19 4.85 6.64 4.86 4.57 4.61 4.67 4.49 4.25 4.05 4.19 4.6 5.68 6 20 4.91 6.33 5.35 4.48 5.09 4.83 4.73 4.32 4.19 3.58 4.86 5.51 6.11 21 4.92 6.2 5.6 4.78 4.87 4.63 4.42 4.06 3.85 3.9 4.94 5.82 6.37 22 4.62 6.03 5.3 4.73 4.49 4.1 4 3.66 3.71 3.63 4.45 5.5 6.3 23 4.79 6.49 5.23 4.82 5 4.35 4.37 3.6 3.92 3.74 5.07 5.53 5.89 24 4.63 6.46 5.18 4.77 4.42 4.18 4 3.38 3.48 3.83 4.81 5.76 6.25 POWER BY HOUR Hour ALL JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC 0 205 493 277 211 177 126 94 51 60 84 195 376 447 1 199 510 267 181 173 106 92 47 69 74 217 309 419 2 217 477 354 246 191 119 125 52 87 94 194 410 355 3 235 445 421 264 216 133 105 47 103 97 255 412 387 4 236 541 402 250 237 129 101 50 64 114 228 491 362 5 217 449 307 292 234 103 77 42 52 104 249 438 401 6 223 495 292 222 228 138 93 43 81 116 304 463 356 7 234 476 301 246 276 142 102 80 71 100 329 481 395 8 220 505 300 244 245 189 100 57 62 94 259 328 392 9 224 449 318 216 231 207 103 64 74 96 291 325 408 10 217 454 272 195 268 188 98 78 70 108 241 413 358 11 208 403 258 212 254 199 114 77 63 110 238 329 344 12 217 398 263 246 253 193 122 99 83 104 211 306 425 13 236 568 219 218 266 231 138 92 95 131 266 399 319 14 238 476 259 251 277 213 154 93 107 128 247 372 368 15 248 496 247 194 274 231 143 121 129 126 256 427 390 16 235 557 240 222 210 178 151 119 124 108 183 476 369 17 250 533 291 251 234 193 186 143 121 151 215 401 363 18 213 503 241 171 195 171 130 105 108 128 167 336 408 19 216 576 244 161 183 160 132 93 91 115 174 352 402 20 226 476 297 139 258 202 157 146 133 86 211 297 372 21 227 417 329 174 242 162 119 86 79 99 241 390 468 22 201 431 279 190 172 135 100 66 68 76 140 370 471 23 217 509 279 196 248 149 126 70 98 93 251 311 351 24 205 493 277 211 177 126 94 51 60 84 195 376 447 SPEED BY DIRECTION Month calm 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360 ALL 0 4.4 4.92 4.35 3.9 3.77 4.63 4.78 5.14 6.55 6.62 5.67 5.36 4.66 4.89 4.67 4.04 3.92 4.2 4.47 3.95 4 3.21 3.35 3.36 3.73 3.99 4.66 5.44 5.66 5.24 5.12 4.65 4.48 4.91 4.83 3.67 4.4 1 0 2.9 4.3 4.9 4 4.6 5 5.3 6 8.9 8.6 7.3 6.5 5.5 6.1 5.5 5.2 4.8 4.7 6.3 4.2 5.4 1.8 4.2 4.7 6.4 5 7.2 8.7 8.7 8.5 7 6.2 6 7.6 6.1 3.6 2.9 2 0 5.1 5 4.6 5.8 5.2 5.9 5.6 7.3 6.6 6.9 5.2 4.6 5.2 4.9 4.3 3.7 5.5 4.4 5.9 4.4 4.8 4.4 2.1 2.9 3.8 3.3 4.2 5.6 6 4.5 5.4 6.1 8.2 8.1 6.7 4 5.1 3 0 5.1 5.4 5 4.3 4.1 4.3 4.3 5.2 6 5.9 5.3 5.4 4.4 5.1 5.2 3.6 3.9 3 3.5 2.3 3.4 2.8 3.4 3.1 2.8 2.6 4.5 6 5.7 6.3 6 5.7 4.8 4.3 6.9 5.1 5.1 4 0 4.5 6 5.2 3.9 3.5 4.4 5.1 4.7 6.6 6.9 6.5 6.7 5.5 5.6 5.7 4.6 4.2 4.2 4.6 4.1 3.9 4.3 3.9 4 3.7 4.3 4.5 5.6 5.9 5.7 5.4 4.4 3.6 4.8 4.7 4.3 4.5 5 0 1.5 4.9 5.3 2.7 3 5.1 4.4 4.5 5.1 6 6.1 4.9 5.2 5.3 4.3 3.9 4 4.7 4.2 5 4.2 2.8 3.7 2.8 3.4 3.3 4.2 4.4 5 5 5.9 4.6 3.6 3.6 2 1.9 1.5 6 0 1.8 2 3.1 2.5 3.1 3.7 3.9 4.7 4.4 4.5 4.4 4.7 4 4.4 4.1 4 4.1 4.3 3.8 4.2 4.2 3.3 4.2 3.8 4 4.3 4.2 4.9 5.3 4.7 5.1 4.7 3.7 4.5 2.5 1.8 1.8 7 0 2.4 1.8 2.3 2.8 2.4 3.2 4 4.2 3.7 3.1 2.5 2.8 2.5 3.1 3.1 2.6 2.7 3.8 3.5 3.3 2.9 3.1 3.1 2.5 3.1 3.6 4.5 5.1 4.7 4.6 4.6 4.2 3.7 4 2.9 2.5 2.4 8 0 3.7 1.8 2 2.3 2.4 2.4 3 2.7 2.9 2.6 2.9 2.9 2.9 3.5 3.4 3 2.6 3.3 3.4 4.2 3.9 3.4 3.8 3.4 3.9 3.9 5 4.7 4.5 4.4 4.7 4.5 4.6 4.7 4.2 3.8 3.7 9 0 2.8 1.5 2.9 2.9 3.2 3.9 4.1 3.8 3.7 4.7 4.4 4.3 4.1 4 4 3.7 3.7 3.6 3.7 3.4 3 2.8 3.2 3.2 3.3 3.5 3.5 4.6 4.7 4.1 4.6 4.5 4.5 3.8 3.9 3.9 2.8 10 0 1.6 4.1 2.2 2.7 2.8 3.8 4.2 3.6 5.8 6.5 5.6 5.9 4.6 5.2 5 4.3 3.5 4.2 4.3 3.4 4 4.1 3.1 3.7 4 5.4 4.9 5.4 5.9 5.9 5.3 4.9 4 3.7 2.8 2.4 1.6 11 0 1.7 6.8 4.7 5 3.9 4.7 6.1 5.2 7.1 7.6 6.3 6.3 5.1 5.1 5.9 4.9 4.3 4 5 2.4 3.6 2.1 2.1 3.2 3.7 3 4.3 6.4 8.6 7.2 4.8 3.7 1.2 1.4 2.2 2.2 1.7 12 0 1.5 5.5 4.4 3.9 4 5.9 5.4 7.4 7.6 7.7 7.2 6.8 6.1 6 5.4 4.9 4.6 4.8 4.6 4.5 4.5 3.2 2.3 2.8 2.8 3.9 4.5 5.5 8.4 8.5 6.3 5.4 2.8 1.2 1.2 1.3 1.5 FREQUENCY BY DIRECTION Month calm 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360 ALL 4.57 8.06 0.84 0.84 1.26 1.27 1.18 1.51 1.79 3.85 6.76 5.84 4.68 3.34 3.59 3.88 3.28 2.69 1.83 1.71 0.96 1.28 1.35 1.63 1.6 1.6 2.12 2.87 4.22 5.51 5.33 5.24 2.89 1.4 1.27 1.16 1.38 8.06 1 3.2 4.2 1 1.2 1.4 1.5 1.9 2.6 2.4 8.7 11.2 5.4 5 3.4 3.5 2.9 2.3 1.8 1.4 1.6 0.6 1.3 0.8 1.3 1.7 1.3 1.8 2.7 3.9 3.6 3.5 2 1.1 1.4 2 2.8 5 4.2 2 5.9 24 1.8 1.5 1.9 1.9 1.6 2 2.6 4 8.1 3.5 2.4 2.2 1.7 2.3 2.1 2 1.7 2.7 0.9 1.1 0.7 0.9 1.1 1.1 1.7 1.3 1.9 2.1 2 2.1 1.6 1.6 1.9 3.1 5.3 24 3 3.7 27.4 2.2 1.8 2 1.7 1.7 2.2 2.4 4.4 6.1 6.2 4.9 3.3 2.1 3.4 2.1 1.5 0.8 1.4 0.6 0.8 0.5 1 1.1 1.2 1.1 1.6 3.2 2.4 2.6 1.8 1.1 0.7 0.5 1 1.1 27.4 4 3.9 21.8 1.9 1.1 1.6 1.2 1.2 1.5 1.7 3.7 5.5 5.7 4.8 3.2 3.8 3.7 3.1 2.4 1.6 1.2 0.7 1.3 1.7 1.3 1.2 1.5 1.8 2.1 3.3 3.9 3.9 2.7 1.1 0.9 0.4 0.8 0.7 21.8 5 3.9 1.2 0.3 0.5 0.9 0.9 0.6 1.4 1.9 3 6.1 7.1 5.4 4.2 5.2 5.4 4 3.2 2.7 2.4 1.6 2 1.6 1.7 1.3 1.5 1.3 2.3 3.1 5.6 6.2 7.1 3.7 1.4 1.7 0.7 0.3 1.2 6 4.2 1.2 0.4 0.6 0.9 0.9 1 1.3 1.8 2.2 4 5.3 5 4 5.3 4.2 3.9 3.5 2.5 1.8 1.2 1.3 1.4 1.7 1.6 1.8 2.2 3.6 4.8 7.2 6.7 8.3 4.2 1.4 1.4 0.8 0.4 1.2 7 4.3 0.8 0.2 0.4 0.6 0.7 0.7 0.9 1.6 1.3 2.6 2.7 2.5 2.1 2.3 2.8 2.5 2.6 1.5 1.2 0.8 1.2 1.7 2.3 1.9 1.8 2.4 4.7 6.9 10 10.1 11 7.2 3.9 2.9 1.3 0.5 0.8 8 4.4 2.7 0.2 0.4 0.4 0.6 0.5 0.6 0.8 1.3 3 3.4 3.6 2.8 3.5 2.9 3.1 2.7 1 1.3 1.6 1.6 2.4 2.7 2.6 2.3 3.2 4.8 5.6 9 9 8.9 5.5 2.2 1.5 1.2 1 2.7 9 7.8 4.7 0.3 0.3 1 0.8 0.5 1 1.7 2.3 4.1 3.7 4.6 3.1 3.6 4.7 3.4 2.6 2.2 1.6 1 1.3 1.4 1.2 1.7 2 2.3 2.8 5.5 7.1 7.9 9 5 1.4 1.5 1.2 1.5 4.7 10 5.7 2.5 0.6 0.6 1.3 1.2 0.8 1.2 1 2.5 6.8 8.6 5.9 4.1 4.8 6.2 4.9 3.8 2.9 2.3 0.9 1.4 1.3 2.1 1.7 1.9 3.8 3.7 5.7 5 4.1 3.6 1.2 0.7 0.4 0.3 0.3 2.5 11 5.3 2 0.5 1.1 2 2.7 2.1 2.2 2.2 6.8 13.7 9.2 5.3 3.6 3.2 4.1 4 2.9 1.6 1.2 0.7 0.9 1.5 1.8 1.8 1.7 2 2.6 3.5 5.3 3.1 2.2 0.6 0.3 0.4 0.5 0.6 2 12 3.3 1.6 0.6 0.6 1.5 1.6 1.8 1.5 1.5 7.8 13.7 11 7.5 4.3 4.3 4.4 4.4 3.5 2.3 1.9 0.8 1.1 1.1 1.4 1.5 1 2.1 1.9 2.8 4 3 1.8 0.9 0.2 0.2 0.3 0.2 1.6 FREQUENCY OF SPEED Month 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 ALL 4.6 13.4 15.5 14.3 11.3 10 7.6 6.1 4.4 3.6 2.7 1.8 1.5 1 0.7 0.5 0.4 0.2 0.2 0.1 0.1 0 0 0 0 0 1 3.2 10.2 13.7 10.7 7.5 7.4 6.7 6.9 6 6 4.8 4.1 3.6 2.8 1.7 1.3 1.2 0.8 0.6 0.3 0.2 0.1 0 0 0 0 2 5.9 13.2 15.5 11.4 9.8 8.7 5.6 6.6 4.5 4.3 4 2.6 2.4 1.4 1.3 1.2 0.5 0.2 0.4 0.1 0.1 0 0.1 0 0 0 3 3.7 13 16 14.5 11.6 9.2 6.7 6 4.3 4.4 3.6 2.4 1.7 1.1 0.6 0.4 0.4 0.1 0.1 0.1 0.1 0 0 0 0 0 4 3.9 12 14.8 13.2 10.6 12 8.7 5.7 4.8 4 2.7 2.2 1.7 1.2 1 0.4 0.6 0.2 0.2 0.2 0.1 0 0 0 0 0 5 3.9 13.6 15.2 15.2 11.5 10.7 8.4 6.4 4.7 3.4 2.5 1.6 1 0.8 0.3 0.3 0.1 0.1 0 0 0 0 0 0 0 0 6 4.2 14.5 16.3 13.8 12.8 12 8.9 7.3 4.2 2.7 1.7 0.7 0.5 0.3 0.1 0.1 0 0 0 0 0 0 0 0 0 0 7 4.3 15.7 17.6 18.1 14.7 11 8.8 4.9 2.6 1.4 0.6 0.3 0.1 0.1 0 0 0 0 0 0 0 0 0 0 0 0 8 4.4 15.6 18.2 18.8 13.4 11.2 7.7 4.5 2.7 1.7 0.9 0.4 0.3 0.1 0 0.1 0.1 0 0 0 0 0 0 0 0 0 9 7.8 15.9 16.9 15.5 11.5 10.7 6.8 5.8 3.8 1.9 1.7 0.8 0.4 0.3 0.1 0 0 0 0 0 0 0 0 0 0 0 10 5.7 13.3 15.8 13.9 11.9 8.2 8.1 5.5 5.1 3.2 3 1.7 1.7 0.7 0.5 0.6 0.4 0.3 0.3 0.1 0.1 0.1 0 0.1 0 0 11 5.3 12.8 13.5 12.8 9.5 8.2 5.9 6.1 5.7 4.7 4.3 2.5 2.6 1.9 1.3 0.6 0.5 0.7 0.4 0.4 0.1 0.1 0 0.1 0 0.1 12 3.3 10.3 11.7 11.7 9.5 9.3 8 7.5 5.4 6 3.6 3.4 2.7 2.4 1.9 1 0.9 0.3 0.5 0.2 0.1 0 0 0 0 0 PERCENT OF POWER BY SPEED Month 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 ALL 0 0.1 0.6 1.5 2.6 4.4 5.7 7.2 7.7 8.8 8.9 8 8.7 7.5 6.2 5 4.7 3.3 3.2 2.2 1.5 0.7 0.3 0.9 0 0.5 1 0 0 0.3 0.5 0.8 1.6 2.5 4 5.1 7.6 7.8 9.1 10.2 10 7.5 6.7 7.3 6.2 4.6 3.4 3 0.8 0.4 0.4 0 0 2 0 0.1 0.5 1 1.8 2.9 3.2 6 5.9 7.8 9.6 8.2 10.5 7.6 8.6 9.5 4.7 2.6 4.8 0.8 2.1 0.6 1.3 0 0 0 3 0 0.1 0.6 1.5 2.7 4 5 7.2 7.6 10.7 11.7 10.4 10 7.8 5.5 4.3 4.5 1.8 0.8 1.6 1.2 0 0 0.9 0 0 4 0 0.1 0.5 1.3 2.3 5 6.1 6.3 7.8 9.2 8.2 8.9 9.3 7.7 7.7 4 6.9 2.1 2.4 2.9 1.2 0 0 0 0 0 5 0 0.1 0.8 2.1 3.5 6.2 8.2 9.9 10.6 10.5 10.7 8.9 7.8 7.6 4 3.7 2 1.9 0.5 0 0 0.9 0 0 0 0 6 0 0.2 1.1 2.7 5.5 9.6 12.3 15.7 13.2 12 9.9 5.6 5.5 3.4 0.9 1.1 0 0 0 0 0 1.3 0 0 0 0 7 0 0.3 1.8 5.2 9.4 13.2 17.6 15.2 11.9 9.2 5 3.2 0.8 1.4 0 0.7 0 0 0 0 1.7 0 0 0 0 3.3 8 0 0.3 1.7 4.9 7.9 12.5 14.3 13.5 11.6 10.4 7.3 4.1 3.7 0.9 0.5 1.5 1.5 0 1.1 0 0 0 0 2.4 0 0 9 0 0.2 1.3 3.4 5.5 9.6 10.7 14.3 13.5 9.5 11.6 7.4 4.2 3.7 2.2 0.6 0.7 0 0 0 1.4 0 0 0 0 0 10 0 0.1 0.6 1.4 2.7 3.5 5.8 6.2 8.6 7.1 10 7.1 9.4 4.9 3.9 5.7 4.5 4 4.4 1.7 2.1 1.6 0 2.6 0 1.9 11 0 0.1 0.3 0.8 1.4 2.2 2.8 4.5 6.3 7.2 9.2 6.7 9.3 8.7 7 3.6 3.8 6.8 4.9 5.6 1 2.3 0.6 2.9 0 1.9 12 0 0 0.3 0.7 1.3 2.5 3.7 5.4 5.7 9 7 8.9 9.4 10.2 10.3 6.5 6.9 2.8 4.9 2.5 1.3 0 0 0.6 0 0 PREVAILING DIRECTION BY HOUR Month 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 ALL 360 360 360 360 90 360 360 360 360 90 360 280 290 280 280 280 360 360 360 360 360 360 360 360 360 1 100 90 90 80 90 80 90 80 90 90 90 90 80 80 90 80 80 90 90 90 90 90 90 90 100 2 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 3 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 4 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 360 5 90 90 90 100 100 90 90 100 110 100 90 160 300 300 300 300 290 290 300 300 140 90 300 90 90 6 300 300 140 270 100 280 90 100 300 100 270 280 300 290 280 290 280 280 300 300 300 280 300 300 300 7 280 300 290 290 300 290 310 290 290 290 280 300 300 280 310 300 280 300 300 280 300 280 280 270 280 8 290 290 290 290 290 300 290 260 260 300 290 280 290 280 280 290 280 300 300 290 280 290 300 310 290 9 300 290 290 90 140 300 360 290 310 280 290 280 290 290 300 300 290 300 290 300 300 300 280 300 300 10 100 140 120 100 100 140 90 100 90 100 100 100 90 90 100 100 100 100 100 130 130 140 280 110 100 11 110 90 90 90 90 90 90 90 90 90 90 90 90 80 100 90 90 90 90 90 90 90 90 100 110 12 90 100 90 100 90 90 90 100 90 90 90 90 90 90 100 80 90 100 90 100 90 100 90 90 90 SPEED FOR PREVAILING DIRECTION BY HOUR Month 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 ALL 4.18 3.71 3.96 4.27 6.45 4.47 4.12 4.61 4.64 6.97 4.97 4.82 4.8 5.92 5.86 6.2 4.73 4.3 4.17 4.42 3.72 4.08 4.05 4.04 4.18 1 6.28 8.75 6.71 8.49 8.58 9.61 8.58 7.86 9.44 8.64 7.32 7.91 7.79 8.46 8.63 10.21 9.68 8.89 9.96 10.4 9.54 9.17 8.62 8.42 6.28 2 4.38 4.35 4.89 4.9 5.32 5.22 4.7 5.52 5.18 5.91 6.17 4.73 5.46 5.27 5.6 5.38 5.98 4.97 5.37 5.37 4.49 5.31 4.85 4.74 4.38 3 4.99 4.38 5.17 5.5 4.59 5.33 5.07 5.14 5.42 5.44 5.07 5.75 5.51 5.37 5.27 5.47 5.36 4.7 4.32 4.7 4.2 5.06 4.99 4.74 4.99 4 4.37 3.9 3.77 4.27 4.43 4.83 4.07 4.87 4.45 5.07 4.94 4.98 5.2 5.09 5.24 5.07 4.67 4.8 4.63 3.9 4 3.58 3.81 4.26 4.37 5 6.27 6.35 6.39 5.85 7.23 3.91 5.38 5.08 5.09 5.9 6.22 4.74 6.57 6.96 8.24 7.33 5.21 5.3 5.99 6.84 5.93 5.2 4.57 6.61 6.27 6 5.09 5.11 4.4 2.91 3.59 4.71 4.92 4.31 4.27 4.75 5.39 5.35 4.92 5.1 5.68 5.87 5.61 5.72 6.02 5.14 4.6 4.48 5.11 6.21 5.09 7 4.15 3.84 4.15 3.95 4.11 3.61 2.96 4.17 4.36 3.99 4.54 4.46 4.58 5.36 5.26 5.17 5.6 5.92 5.09 4.92 5.01 4.79 4.67 5.43 4.15 8 4.34 4.19 4.92 4.49 4.19 3.63 3.99 5.84 4.51 4.16 4.47 4.56 4.37 4.86 5.3 5.45 4.6 5.04 5.09 4.04 5.31 4.1 4.29 3.41 4.34 9 4.91 4.73 4.18 3.95 4.27 5.79 2 3.12 4.31 3.76 4.77 4.92 3.92 4.06 5.57 5.15 4.61 5.78 4.48 4.65 3.73 3.43 4.9 4.84 4.91 10 5.92 5.41 4.31 5.47 5.13 4.19 5.05 6.08 6.4 6.51 5.75 5.29 6.28 7.23 5.98 4.92 5.83 5.7 5.97 5.1 4.52 4.96 4.12 6.49 5.92 11 7.03 6.81 9.31 8.32 10.03 9.07 9.26 7.05 7.45 8.81 7.65 6.7 5.12 6.93 4.63 6.9 6.84 6.39 7.89 7.31 7.4 8.85 8.28 8.78 7.03 12 7.42 8.21 9.07 6.53 7 8.31 7.59 8.23 8.79 7.62 7.29 7.14 8.71 7.39 7.34 7.97 8.48 8.33 7.17 8.03 7.56 6.26 5.9 8.67 7.42