Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Emmonak_longterm-data
EMMONAK AK - 702084 62 deg 46' N 164 deg 30' W - Elev 3m LST=GMT+99 hours *NT=-11 10/77-10/80 10/83-09/02 Adjusted to Alaska Timezone (GMT-9) SPEED BY YEAR Year ALL JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC ALL 4.79 5.21 5.53 5.36 5.22 4.64 4.22 4.1 4.59 4.49 4.42 5.17 4.82 1977 3.83 -1 -1 -1 -1 -1 -1 -1 -1 -1 4.18 2.8 3.55 1978 5.34 4.08 5.66 5.14 5.16 3.23 5.61 4.5 4.32 5.67 6.33 7.05 5.5 1979 4.89 5.45 2.98 5.82 6.02 4.53 5.74 7.38 6.57 5.62 3.98 4.77 3.63 1980 4.84 3.41 5.61 5.25 5.12 -1 -1 5.1 3.37 3.8 5.77 -1 -1 1983 5.26 -1 -1 -1 -1 -1 -1 -1 -1 -1 5.32 5.13 5.33 1984 5.19 4.8 4.84 6.41 5.56 5.15 4.7 5.64 5.48 4.79 4.81 4.38 5.59 1985 5.2 5.82 5.45 5.81 4.75 5.53 4.96 4.21 5.18 4.96 5.32 4.89 5.37 1986 4.43 4.53 4.12 4.82 -1 -1 -1 -1 -1 -1 -1 -1 4.1 1987 4.35 4.99 5.23 4.5 4.85 4.49 4.37 3.31 3.22 4.62 3.98 3.96 4.39 1988 4.81 3.84 6.26 5.6 5.51 5.2 5.55 3.95 4.24 4.32 4.54 4.14 5.43 1989 5.15 4.7 7.1 5.41 6.25 6.42 -1 -1 3.22 2.69 5.01 5.09 4.94 1990 4.61 4.53 4.69 3.69 3.5 3.12 4.01 4.89 5.91 5.77 4.95 5.62 5.14 1991 5.09 5.73 5.67 5.86 4.69 4.19 4.79 4.58 4.19 4.86 5.77 5.59 4.66 1992 4.37 3.61 4.32 4.3 4.96 4.22 4.66 -1 -1 -1 -1 -1 -1 1993 2.9 1.85 3.51 -1 2.42 2.71 2.36 2.89 3.04 3.89 2.89 2.92 2.37 1994 3.97 2.1 -1 3.41 -1 -1 -1 -1 -1 4.11 4.12 6.08 4.57 1995 6.33 5.99 7.42 6.37 5.81 3.6 -1 3.3 7.7 4.99 4.1 -1 6 1996 4.62 -1 -1 -1 -1 -1 -1 4.45 4.87 4.46 4.01 5.67 4.42 1997 4.65 5.02 5.48 4.49 4.53 4.61 3.9 3.72 4.55 4.31 4.4 5.8 4.74 1998 4.77 5.36 5.23 5.14 6.16 5.27 4.01 3.39 4.7 4.51 4.41 4.53 4.35 1999 4.64 5.74 4.84 5.23 6.1 4.4 4.07 4.49 4.23 4.39 3.25 5.11 3.91 2000 5.21 4.37 6.4 6.26 4.89 4.43 3.75 4.32 4.97 5.65 4.57 6.45 6.65 2001 5.09 6.23 6.51 6.24 5.63 5.19 4.66 4.59 4.93 4.18 4.58 4.41 4.27 2002 4.61 7.16 6.55 5.72 5 4.56 4.2 3.78 4.43 2.92 -1 -1 -1 POWER BY YEAR Year ALL JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC ALL 144 216 219 182 186 116 77 80 111 105 117 179 171 1977 73 -1 -1 -1 -1 -1 -1 -1 -1 -1 79 24 139 1978 169 51 188 133 151 44 164 83 89 175 252 369 213 1979 137 173 45 163 219 88 172 266 218 151 74 199 102 1980 137 97 172 150 116 -1 -1 80 33 45 129 -1 -1 1983 157 -1 -1 -1 -1 -1 -1 -1 -1 -1 151 147 173 1984 141 125 119 222 164 116 84 165 150 96 133 97 207 1985 147 215 152 173 112 228 101 66 115 117 174 136 166 1986 107 108 94 116 -1 -1 -1 -1 -1 -1 -1 -1 111 1987 110 182 181 127 125 106 97 48 50 111 85 83 134 1988 119 80 214 179 157 129 136 50 78 77 91 75 179 1989 175 207 362 174 243 218 -1 -1 33 24 146 186 140 1990 121 113 131 63 52 28 63 135 225 185 130 194 164 1991 148 223 203 240 91 79 96 81 77 93 179 213 132 1992 112 66 109 95 137 135 111 -1 -1 -1 -1 -1 -1 1993 52 9 111 -1 26 26 18 40 84 81 64 53 20 1994 111 15 -1 68 -1 -1 -1 -1 -1 82 86 298 121 1995 421 394 672 238 143 30 -1 23 274 93 44 -1 210 1996 138 -1 -1 -1 -1 -1 -1 109 129 132 104 223 140 1997 131 182 209 125 121 132 57 52 89 93 108 208 151 1998 151 189 156 154 319 152 73 40 115 108 112 160 217 1999 147 364 165 183 276 91 66 104 106 101 50 185 100 2000 175 133 261 262 140 98 54 89 144 169 152 279 316 2001 174 320 415 255 241 146 89 112 115 72 135 108 152 2002 124 382 330 232 173 104 78 64 96 25 -1 -1 -1 NUMBER OF SPEED OBSERVATIONS BY YEAR Year ALL JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC ALL 76290 6183 5805 6118 5930 7535 6754 7341 7541 5144 6095 5924 5920 1977 113 0 0 0 0 0 0 0 0 0 78 24 11 1978 692 9 48 72 57 22 77 93 75 58 64 65 52 1979 684 64 87 53 56 86 99 5 21 72 36 29 76 1980 550 147 162 172 60 0 0 1 3 2 3 0 0 1983 754 0 0 0 0 0 0 0 0 0 245 252 257 1984 2957 261 251 282 259 230 222 245 231 226 261 253 236 1985 2754 251 230 250 199 239 206 239 262 249 250 184 195 1986 761 203 187 221 0 0 0 0 0 0 0 0 150 1987 1957 132 143 148 216 195 184 138 145 170 180 152 154 1988 1923 148 194 160 157 58 11 38 226 255 232 259 185 1989 1791 186 162 148 68 252 0 0 173 96 222 235 249 1990 2527 268 242 248 177 244 186 167 216 155 224 199 201 1991 2426 286 161 259 216 246 259 213 149 22 233 166 216 1992 1032 98 224 202 159 229 120 0 0 0 0 0 0 1993 1457 77 154 0 123 197 113 183 136 156 157 107 54 1994 545 124 0 93 0 0 0 0 0 57 81 99 91 1995 270 135 75 19 17 1 0 2 1 11 1 0 8 1996 3956 0 0 0 0 0 0 519 726 704 734 570 703 1997 7290 700 590 616 676 732 633 519 235 693 604 680 612 1998 7867 651 623 700 705 729 533 691 556 695 709 700 575 1999 8407 641 623 716 707 763 738 755 755 653 646 677 733 2000 7655 642 624 734 703 728 679 713 734 187 500 691 720 2001 7250 705 502 413 668 524 690 707 723 659 635 582 442 2002 10672 455 523 612 707 2060 2004 2113 2174 24 0 0 0 NUMBER OF SPEED OBSERVATIONS BY HOUR Hour ALL JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC 0 2234 172 149 153 160 227 225 257 236 160 174 163 158 1 2243 155 148 173 185 232 224 252 256 148 157 153 160 2 2187 157 143 151 175 230 206 246 237 142 171 163 166 3 2221 157 153 148 172 233 228 253 251 160 151 157 158 4 2227 169 145 151 171 219 235 255 244 151 162 158 167 5 2217 156 146 163 168 233 216 245 240 151 173 163 163 6 2785 168 150 149 246 343 292 307 324 224 255 167 160 7 3689 276 259 259 286 400 338 360 390 279 323 253 266 8 4124 294 313 336 340 428 350 383 409 312 380 305 274 9 4702 413 389 391 353 466 369 412 424 326 411 367 381 10 4736 433 406 432 365 436 377 401 406 296 395 384 405 11 4637 399 380 411 362 439 367 391 414 319 393 394 368 12 4523 392 369 379 353 437 380 381 410 307 376 384 355 13 3686 381 389 390 264 293 269 297 272 160 254 354 363 14 3402 219 207 237 276 369 296 347 397 293 315 215 231 15 3915 342 321 327 298 394 324 326 384 255 323 314 307 16 3450 341 314 317 232 275 279 296 304 210 229 313 340 17 3861 250 228 256 321 442 380 387 416 307 384 256 234 18 3473 387 356 372 252 242 242 259 256 168 204 367 368 19 2616 175 158 186 190 282 277 299 299 190 215 172 173 20 2636 234 229 245 221 233 220 243 241 136 182 225 227 21 2238 171 149 170 171 230 222 245 250 167 144 155 164 22 2291 185 159 171 193 222 220 258 239 138 167 176 163 23 2197 157 145 151 176 230 218 241 242 145 157 166 169 SPEED BY HOUR Hour ALL JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC 0 4.31 5.73 5.47 4.75 4.74 3.88 3.27 3.5 3.91 3.78 3.87 5.28 4.8 1 4.35 5.71 5.59 4.9 4.93 3.97 3.18 3.27 4.04 3.98 3.78 5.47 4.83 2 4.26 5.75 5.59 5 4.71 3.88 3.12 3.26 3.74 4.07 3.76 5.22 4.51 3 4.26 5.58 5.58 5.24 4.52 3.88 3.01 3.47 3.76 4.02 3.91 5.05 4.69 4 4.24 5.39 5.54 5.19 4.93 3.87 2.98 3.22 3.68 4.05 3.83 5.24 4.7 5 4.3 5.73 5.91 5.18 4.53 3.88 3.07 3.19 3.69 4.05 3.84 5.3 4.95 6 4.22 5.59 5.71 5.19 4.38 3.93 3.29 3.3 3.89 3.83 4.09 5.13 4.73 7 4.37 5.2 5.52 5.17 4.47 4.04 3.68 3.7 3.78 3.95 4.2 5.08 4.67 8 4.45 5.14 5.47 5 4.38 4.25 3.89 3.84 4.07 3.94 4 5.09 4.99 9 4.55 4.74 5.36 4.9 4.68 4.44 4.21 3.85 4.25 4.09 4.12 5 5 10 4.74 4.9 5.33 5.07 4.99 4.7 4.24 4.11 4.76 4.49 4.38 4.96 4.87 11 4.87 4.76 5.26 5.3 5.35 4.83 4.42 4.28 4.97 4.86 4.47 5.14 4.82 12 5.05 4.92 5.51 5.43 5.63 5.07 4.64 4.37 5.11 4.99 4.76 5.26 4.91 13 5.27 4.91 5.65 5.66 5.99 5.28 4.75 4.64 5.44 5.38 5.16 5.3 5.06 14 5.38 5.51 6 6.14 6.06 5.4 4.89 4.62 5.39 5.36 5.35 5.56 4.78 15 5.33 5.14 5.86 5.95 5.99 5.29 5.05 4.66 5.35 5.32 5.27 5.18 4.91 16 5.43 5.19 5.83 5.77 6.18 5.79 5.26 5.06 5.78 5.42 5.29 5.4 4.46 17 5.35 5.39 5.55 6.26 5.62 5.5 5.27 4.95 5.33 5.41 5.09 4.98 5.09 18 5.17 5.07 5.12 5.61 5.93 5.5 5.21 4.92 5.45 5.01 4.52 4.93 4.72 19 5.13 5.57 5.69 5.23 5.73 5.24 5.25 4.91 5.28 4.47 4.29 5.22 4.85 20 4.96 5.26 5.42 5.48 5.48 4.81 5.17 4.58 4.89 4.1 3.87 5.07 4.84 21 4.65 5.46 5.48 5.05 5.14 4.3 4.49 4.32 4.33 3.79 4.04 5.21 4.72 22 4.51 5.48 5.53 5.11 5.14 4.12 3.94 3.87 4.02 3.68 3.84 5.28 4.63 23 4.37 5.57 5.4 4.99 4.95 3.91 3.43 3.51 3.9 3.86 3.96 5.26 4.87 POWER BY HOUR Hour ALL JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC 0 120 277 209 130 155 71 38 57 73 74 95 194 180 1 124 275 219 159 162 77 34 47 78 89 79 208 193 2 121 285 246 167 155 74 31 47 65 85 81 187 159 3 118 260 219 165 148 71 29 60 67 83 92 182 165 4 120 250 222 162 180 70 29 47 61 92 90 185 182 5 126 267 255 181 150 73 33 43 69 88 97 193 198 6 116 281 251 182 132 83 46 48 79 66 101 163 171 7 125 233 225 183 149 87 53 61 72 70 131 172 154 8 123 209 211 165 125 95 61 70 90 72 91 172 176 9 126 170 200 149 151 109 75 68 88 77 97 163 166 10 138 183 209 163 158 130 77 79 120 92 107 159 155 11 146 170 191 177 186 128 90 90 137 121 119 182 164 12 161 182 239 186 212 138 97 101 150 123 134 190 179 13 174 181 225 204 235 162 98 105 162 147 156 190 179 14 179 247 261 252 259 160 101 100 160 152 167 212 176 15 175 202 250 220 237 145 111 102 154 159 165 192 172 16 179 206 238 201 252 186 114 121 179 162 159 186 142 17 166 223 214 243 196 161 122 118 144 159 146 155 190 18 159 192 165 184 220 155 117 113 146 133 120 161 157 19 153 246 236 174 209 144 116 111 128 96 108 174 183 20 147 202 209 181 207 110 122 91 107 85 81 162 171 21 132 264 210 148 190 85 77 82 89 69 93 188 168 22 130 249 212 161 194 83 59 63 76 64 94 187 188 23 122 243 214 153 171 74 40 59 67 85 86 194 187 SPEED BY DIRECTION Month calm 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360 ALL 0 4.63 4.52 4.89 5.27 5.56 5.26 5.63 4.83 4.35 4.56 4.87 5.49 6.71 6.17 5.87 5.86 5.61 5.2 4.75 4.35 4.33 4.52 4.65 4.85 4.75 4.62 4.59 4.28 4.2 4.29 4.41 4.73 4.96 4.71 4.52 4.43 4.63 1 0 5 4.6 5.7 6.5 6.7 5.6 6.5 5.1 4 4.5 4.8 5.4 6.7 6.9 7.4 6.6 6.3 6 4.7 4.3 4.3 4.4 5.1 4.6 3.6 3.6 3.9 4.2 4.3 4.6 4.5 5.2 5.3 4.2 4.5 4.3 5 2 0 5.1 4.6 5.2 5.7 5.6 5.9 6.5 5.7 4.5 5.4 5.4 6.4 7.9 7.2 6.5 6.9 6.5 6.3 5.3 5.8 5 5.3 5.2 6.5 3.3 3.6 3.7 4.5 3.9 3.9 4.4 4.7 5 4.8 4.6 5 5.1 3 0 5.1 5.1 5.5 5.2 5.6 6 6.1 5 4.7 4.9 5.4 5.6 7.6 7.4 6.4 6.2 6.3 5.4 5.4 4.5 4.3 5.4 4.5 4.8 5 4.1 4.4 4.9 5.7 4.3 5 5.8 5.4 4.8 4.9 5.1 5.1 4 0 4.8 4.9 5.1 5.2 5.5 5.2 5.1 5.2 4.5 4.5 5 5.9 7.3 6.6 6.3 7 7.1 5.2 4.9 4.8 4.7 5.8 5.8 5.9 5.1 5.6 5.5 4.9 4.7 5.1 4.9 5.4 6.2 5.8 5.5 5.2 4.8 5 0 4.4 4.5 4.7 4.9 4.7 4.4 5.4 4.4 3.8 4.1 3.5 4.5 5.6 5.6 5.7 5.9 5.6 5.4 4.9 4 4 4.5 4.8 5 5 4.6 4.8 3.9 4.1 4.5 4.1 4.8 5 5 4.8 4.6 4.4 6 0 4.3 4.4 4.6 4.5 4.7 4.7 5.3 4.4 4.1 4 4.5 4.4 5 4.5 4 4.6 4.5 4.6 4.4 4 4.1 4.5 4.4 4.7 4.5 4.4 4.3 4 4.2 4.3 4.2 4.2 4.5 4.3 4.2 4.1 4.3 7 0 3.9 3.6 3.7 3.6 3.7 3.9 3.8 4 3.7 3.4 3.5 4.2 4.5 5 4.9 4.6 4.8 5 4.8 4.6 4.5 4.3 4.7 4.6 4.6 4.4 4.5 4.5 4 4 4 4.1 4.5 4.4 4.3 3.7 3.9 8 0 4.1 3.9 4.3 5 5.7 4.6 4.2 3.7 3.8 4 4 4.9 6 5.4 5.4 5.8 5.4 5.4 4.8 4.9 4.6 4.7 4.7 5.2 5.5 5.1 5.1 4.8 4.2 4.4 4.4 4.9 4.6 4.4 4 3.8 4.1 9 0 4.9 4.6 5 5.1 5 4.3 4.2 4.3 4.1 4.4 4.4 4.4 4.1 4.7 4.8 5.7 5.3 4.8 4.9 4.4 4.2 4 4.1 4.5 4.9 5.3 4.4 4 3.8 4.1 4.2 4.6 5.6 5.3 4.9 4.5 4.9 10 0 4.9 4.9 4.7 5.1 5 4.9 5.1 4.7 4.3 4.1 4.6 4.6 5.9 5.3 5.7 5.5 5.2 4.7 4.8 3.7 3.9 3.9 4.2 3.6 3.9 4.3 4.1 3.8 4.2 4.4 5 4.5 4.2 4.3 4 4.2 4.9 11 0 4.6 4.7 4.8 5.2 6 5.6 5.2 4.6 4.8 4.9 5.5 6.1 7.3 6.7 6.2 6.1 5.5 5 4.3 3.8 4.3 4.4 3.4 5.4 4.5 4.3 4.5 3.7 3.1 3.5 4.1 4.5 4.8 5.2 4.9 4.6 4.6 12 0 4.3 4 4.6 5.5 6 5.5 6.1 4.9 4.8 5.1 5.8 6.6 7.6 6.8 6.2 6.2 5.6 5.2 4 3.2 3.8 3.6 3.9 3.9 3.5 3.4 4.1 3.8 4.2 4.2 4.7 4.5 5.2 4.8 4.2 4.6 4.3 FREQUENCY BY DIRECTION Month calm 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360 ALL 4.1 4.41 4.54 4.49 4.86 4.61 4.34 3.97 3.03 2.52 2.43 2.11 2.48 3.31 2.66 2.23 2.52 3.05 2.76 2.62 1.94 2.03 2.07 2.05 1.94 1.46 1.49 1.45 1.37 1.34 1.78 1.99 2.68 3.41 2.97 3.35 3.76 4.41 1 5.3 5.1 6.4 5.7 7.1 8.1 6.3 6.2 4.5 3.2 2.7 2 2.4 3.5 2.6 2 2.2 2.3 2.6 1.7 1.1 1.3 1.2 0.9 0.6 0.6 0.5 0.6 0.7 0.6 1.4 1.3 2.1 2.5 2 2.6 3.2 5.1 2 3.1 5.5 4.5 4.3 6 5.1 7 7.1 5.2 3.9 3.1 2.8 3.9 5.7 4.6 2.6 2.5 3.5 2.2 1.7 0.7 0.9 0.7 0.4 0.4 0.3 0.6 0.5 0.4 0.6 1.1 0.9 1.8 2 1.8 2.1 3.6 5.5 3 2.5 4 5.4 6.2 7.2 6 7.1 7.8 4.7 4.3 4.3 3.2 2.6 4.1 2.6 1.5 1.7 2.1 1.5 1.2 0.8 0.8 1 0.8 0.7 0.5 0.6 0.7 0.7 0.8 1.1 1.3 2.7 2.9 2 2.2 2.9 4 4 3.5 4.7 5.5 5.1 6.9 6.1 4.3 3.8 3.6 2.9 2.6 1.9 1.6 2.7 2.3 2.3 2.1 2.7 2.8 2.7 2 2.1 2 2 1.4 1 1.1 1.2 1.2 1 1.5 1.7 2.2 3.7 2.6 3.3 3.4 4.7 5 3.2 4.2 3.3 4 4.2 3.4 3.4 3.2 2.2 1.8 1.6 1.4 1.9 3.4 2.9 2.9 2.7 3.1 2.8 3.2 2.2 2.5 2.2 2 2.3 2 2 1.7 1.2 1.2 1.5 1.9 2.7 4.6 4.5 4.9 4.8 4.2 6 4 4.6 4.3 3.9 3.6 3.1 3.8 3.2 2.2 1.7 1.5 1.2 1.3 1.6 1.8 1.4 2.1 2.5 2.7 3.3 2.1 1.8 2.4 2 1.9 1.9 1.9 1.9 2 2.4 3 3.2 4.2 4.5 4.6 4.7 5.7 4.6 7 5.2 2.6 2 2.6 1.9 1.6 2.1 1.6 1.5 1.1 1.2 1.3 1.3 1.7 1.9 1.5 2.6 3.6 4.2 3.9 3.3 3.7 3.3 5.4 5.1 3 2.9 2.8 2.3 2.4 2.7 3.1 3.6 4.7 4.2 3.9 3.2 2.6 8 3.2 3.9 4 3.8 3.6 3.4 1.8 1.4 1.1 1.2 1.4 1.2 1.5 2 1.8 1.8 2.4 3.3 2.7 2.9 2.8 3.4 3.9 4.2 4 3.1 3.1 2.7 2.3 1.8 2.1 2.9 3.5 4.7 3.2 4 3.1 3.9 9 3.3 4.1 4.3 3.5 3.3 3.1 2.7 2.8 2.4 2.8 3 3 3 2.1 2.3 1.9 3 3.4 3.7 3.7 3.2 2.6 2.6 2.1 2 1.6 1.6 1.5 2 2.3 2.5 2.5 2.8 3.2 2.9 3.1 3.5 4.1 10 5.1 5.5 5.6 5.3 4.9 5.3 4 3.2 2.8 2.4 2.6 1.7 1.8 1.9 2.1 2.2 2.8 3.2 3 3.2 2.1 2.1 2.2 1.7 1.4 1 1.3 1.6 1.7 1.6 2.2 2.7 2.6 2.8 2.5 3 4.1 5.5 11 3.8 4.3 4.3 4.4 4.3 5.6 6 3.6 3.2 2.9 3.2 3.6 5.1 7 4.8 4.3 3.7 4.7 3 2 1.4 1.5 1.3 0.6 1.1 0.8 0.8 0.8 0.4 0.2 0.6 0.6 0.9 1.3 1.7 2.6 3.2 4.3 12 7 4.9 5.9 5.7 6.2 5.7 4.7 4.9 4.1 3.1 2.7 2.9 4.1 4.7 2.8 2.4 2.5 2.3 1.6 1.7 1.1 0.7 1.3 1.1 1 0.8 0.6 0.7 1.2 0.9 1.3 1.3 2.5 2.9 2.8 3 4 4.9 FREQUENCY OF SPEED Month 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 ALL 4.1 4.6 14.9 17.2 16 13.8 10.1 8.3 4.1 2.9 1.8 1 0.6 0.3 0.1 0.1 0 0 0 0 0 0 0 0 0 0 1 5.3 4.8 14.6 13.8 13.7 11.9 9.2 9.3 5.5 3.8 2.8 1.9 1.5 0.5 0.4 0.4 0.1 0.1 0.1 0 0 0 0 0 0 0 2 3.1 3.8 10.3 14.2 14.5 14.5 11.2 10.3 5.5 4.3 3.5 2.2 1.3 0.8 0.2 0.1 0.1 0 0 0.1 0 0 0 0 0 0 3 2.5 3 10.8 15.8 15 14.6 11.1 11.4 5.8 4.2 2.9 1.5 0.8 0.2 0.2 0 0 0 0 0 0 0 0 0 0 0 4 3.5 3.6 12.1 15.7 16.4 13.7 10.3 9.1 5.4 4.2 2.2 1.5 0.9 0.7 0.3 0.2 0.1 0.1 0 0 0 0 0 0 0 0 5 3.2 4.8 15 17.8 17.1 14.7 11.3 7.9 3.8 2.4 1 0.6 0.3 0.1 0.1 0 0 0 0 0 0 0 0 0 0 0 6 4 4.6 15.3 20.3 20.4 16.4 10.5 5.5 2 0.8 0.2 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 7 5.2 5.9 17.5 19.8 19.2 14.3 9.2 5 1.5 1.2 0.7 0.3 0.1 0.1 0 0 0 0 0 0 0 0 0 0 0 0 8 3.2 3.9 16.8 18.9 16.2 14.7 11.3 7.3 3.2 1.9 1.5 0.7 0.3 0 0 0 0 0 0 0 0 0 0 0 0 0 9 3.3 4.5 16.5 19.8 17.4 13.6 9.7 8.2 3.1 1.9 0.9 0.5 0.2 0.1 0.1 0 0 0 0 0 0 0 0 0 0 0 10 5.1 5.8 19.2 18.1 13.4 12.6 9 7.9 3.4 2.7 1.5 0.6 0.5 0.1 0 0 0 0 0 0 0 0 0 0 0 0 11 3.8 4.7 13.3 15.1 14 13.2 10.4 9.5 5.3 4.3 3 1.8 0.9 0.4 0.1 0.2 0 0 0 0 0 0 0 0 0 0 12 7 5.5 15.8 15.6 13 10.3 8 10 5.5 3.7 2.4 1.1 1.1 0.5 0.3 0.1 0 0 0 0 0 0 0 0 0 0 PERCENT OF POWER BY SPEED Month 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 ALL 0 0.1 0.9 3 5.8 9.5 12 15.6 11 11 9.5 7 5.6 3.2 1.9 1.5 0.5 0.4 0.5 0.3 0.2 0 0.1 0.1 0 0.1 1 0 0 0.6 1.7 3.5 5.7 7.6 12.1 10.3 10.3 10.2 8.7 9 4.2 3.8 4.7 1.3 2 2.6 1.1 0.8 0 0 0 0 0 2 0 0 0.4 1.7 3.7 6.8 9 13.2 9.9 11 12 9.9 7.8 6.1 2 1.1 1.3 0.5 0.6 1.1 0.4 0 0 0.6 0 0.8 3 0 0 0.6 2.2 4.6 8.1 10.7 17.4 12.6 13 12.1 8.1 5.7 1.7 2 0.4 0.5 0 0 0 0 0 0 0 0 0 4 0 0 0.6 2.1 4.7 7.4 9.6 13.4 11.4 12.7 8.9 7.8 6.1 6.1 3.7 2.1 0.8 0.9 0.7 0.4 0.5 0 0 0 0 0 5 0 0.1 1.1 3.8 7.6 12.6 16.5 18.1 12.4 11.3 6.2 5.2 2.9 0.8 0.9 0.3 0.3 0 0 0 0 0 0 0 0 0 6 0 0.1 1.7 6.5 13.4 20.5 22.1 18.2 9.6 5 2 0.2 0.2 0 0 0.4 0 0 0 0 0 0 0 0 0 0 7 0 0.2 1.8 5.9 12.1 16.9 18.7 15.9 7 7.6 5.9 3.7 1 1.8 0.3 0.4 0 0 0 0 0.8 0 0 0 0 0 8 0 0.1 1.3 4.1 7.5 12.7 16.8 17.1 10.6 9.2 9.8 5.7 3.3 0.5 0.6 0 0.7 0 0 0 0 0 0 0 0 0 9 0 0.1 1.4 4.5 8.5 12.4 15.1 20.1 11.1 9.7 6.2 4.7 2.4 1.4 1.1 0.9 0.5 0 0 0 0 0 0 0 0 0 10 0 0.1 1.5 3.8 5.9 10.4 13 18.2 11 12.7 9.2 4.9 5.4 1.7 0.8 0.3 0 0 0 0 0 0 0 1.1 0 0 11 0 0.1 0.7 2.1 4.2 7.5 10 14.3 11.4 13 12.6 9.5 6.6 3.5 1.5 2.4 0 0 0 0 0 0 0.7 0 0 0 12 0 0.1 0.9 2.4 4.1 6 8.3 16.3 12.8 12 10.7 6.7 8.4 5.2 3.2 1.4 0 0.6 0.8 0 0 0 0 0 0 0 PREVAILING DIRECTION BY HOUR Month 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 ALL 10 20 10 10 20 60 10 10 20 30 30 30 30 30 40 30 30 30 30 360 40 360 10 10 1 60 60 40 30 30 60 10 30 40 40 40 40 40 40 40 10 40 40 40 30 40 70 60 60 2 120 60 50 60 60 60 50 60 60 360 360 30 50 30 70 30 30 50 20 50 120 120 60 50 3 60 50 50 50 60 60 60 60 30 30 30 30 30 20 50 30 60 20 30 60 20 60 60 60 4 70 20 20 30 10 360 30 20 30 30 40 30 30 30 30 30 40 30 30 320 40 20 30 30 5 20 320 340 10 90 350 350 360 120 340 30 160 30 30 320 30 360 340 330 350 330 340 340 350 6 350 350 350 350 20 320 10 20 330 340 340 330 360 330 350 350 330 310 340 340 350 10 350 350 7 220 220 320 230 220 220 220 230 230 220 170 170 160 320 170 320 200 300 330 330 320 330 230 220 8 10 20 320 10 320 10 20 220 160 200 20 40 230 40 40 340 210 320 220 330 310 320 220 340 9 80 10 10 350 160 160 10 10 20 170 360 170 20 180 40 30 40 30 350 350 350 300 360 10 10 10 360 10 10 20 20 40 360 40 20 360 360 30 30 40 40 30 40 10 360 20 360 30 10 11 160 50 50 120 20 120 120 120 50 40 50 50 120 120 50 120 40 40 120 130 50 120 50 100 12 10 110 120 30 30 350 20 40 20 30 30 30 30 40 20 10 20 40 50 70 40 100 10 60 SPEED FOR PREVAILING DIRECTION BY HOUR Month 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 ALL 3.88 4.2 4.02 3.87 3.95 5.76 3.93 4.24 4.45 5.04 5.11 5.13 5.2 5.72 6.04 6.05 6.02 5.95 5.91 4.88 5.55 4.35 4.01 3.73 1 7.46 6.35 9.19 7.23 8.14 7.45 4.58 5.82 6.83 6.12 5.99 5.52 5.5 5.63 7.56 5.49 6.36 7.1 6.38 6.66 5.95 5.17 6.21 8.02 2 6.98 5.52 6.54 6.92 6.71 6.91 4.99 5.44 5.77 5.17 4.83 5.87 6.27 5.54 6.59 6.32 6.44 6.39 5.26 6.56 6.87 6.97 6.02 4.43 3 5.46 5.92 5.86 5.24 5.72 6.5 6.33 7.77 5.12 4.61 4.69 5.21 5.28 5.75 7.06 6.51 6.28 6.69 6.22 6.49 6.6 5.26 6.18 5.53 4 4.03 5.02 4.72 4.43 5.24 4.38 4.76 4.79 4.3 4.9 5.31 5.03 5.23 6.68 5.72 6.4 7.04 5.26 6.22 5.51 5.52 5.25 4.93 4.44 5 3.52 3.9 3.94 4.11 4.13 4.06 3.65 3.24 4.64 4.04 4.53 5.39 4.89 5.02 6.47 5.5 5.35 5.38 5.52 5.25 4.97 4.08 3.91 3.99 6 3.3 3.02 2.93 3.31 3.25 3.05 3.27 3.3 3.57 3.7 4.5 4.24 4.79 4.22 3.89 5.33 5.21 4.92 5.26 5.14 5.26 5.07 3.99 3.04 7 4.84 4.27 3.51 4.71 3.22 4.51 3.94 4.01 3.96 5.04 4.71 5.42 4.31 5.45 4.66 5.21 5.04 5.1 4.8 4.81 4.42 4.57 4.69 4.48 8 3.49 3.45 3.45 3.55 4.06 3.16 3.06 3.89 5.93 4.2 3.55 4.86 4.94 7.15 6.32 5.4 6.11 5.59 5 4.24 5.44 4.56 4.21 3.68 9 4.68 4.36 4.69 4.28 4.26 6.23 3.53 4.11 3.48 3.78 5.11 5.01 5.9 5.72 5.16 5.92 5.94 6.08 3.28 3.85 3.68 3.54 4.08 2.98 10 4.42 3.34 3.95 4.07 3.62 4.05 4.01 4.98 4.73 3.97 4.39 4.41 5.53 6.45 6.17 6.23 5.56 5.29 5.74 4.77 4.77 4.78 4.57 4.44 11 6.9 6.48 4.6 7.3 4.72 7.46 7.18 8 5.83 6.21 5.01 5.21 6.66 7.43 6.15 7.22 6.7 5.95 6.34 6.88 4.96 7.14 6.36 5.22 12 3.27 6.43 7.22 6.37 5.15 3.66 3.49 7.03 4.86 6.24 5.77 5.32 5.71 5.6 4.8 3.61 5.02 4.91 5.45 3.98 5.24 6.51 4.9 6.46